PROCEDURE FOR TESTING SENSORS

1. Radiator water level sensor

1) Stop the engine, turn the starting switch


OFF, and remove the sensor from the radi-
ator.
2) Put the test pin of the tester in contact
with the sensor connector.
3) Move the sensor float up and down, and
measure the resistance between terminals
1 and 2.

* Judgement

Condition When normal

Float up Max. 1 Q

Float down Min. 1 M 8

1. Float
0 The relationship between the sensor and 2. Switch
the position of the float is as follows. 3. Connector
Float above specified level: CLOSED (ON)
Float below specified level: OPEN (OFF)

Structure of circuit

i i 56lFO3177

2. Engine oil level sensor

1) Stop the engine, turn the starting switch


OFF, and remove the sensor from the en-
gine.
2) Connect a T-adapter to the sensor connec-
tor.
3) Move the sensor float up and down, and
measure the resistance between terminal
1 and the bracket.

j, Judgement

Condition When normal

Float up I Max. 1 R

Min. 1 M Q 1. Connector
Float down I
2. Bracket
3. Float
l The relationship between the sensor and 4. Switch
the position of the float is as follows.
Float above specified level: CLOSED (ON)
Float below specified level: OPEN (OFF)

f Down Structure of circuit

I97FO2077

20-46
3. Engine oil pressure sensor

1) Stop the engine and turn the starting


switch OFF.
2) with the sensor still installed to the engine,
disconnect the wiring harness from the
sensor. 1 2 3 4 5 6
3) Measure the resistance between the termi-
nal and the chassis with the engine \\I///

@ @
stopped and with the engine running.

* Judgement

Condition of sensor

Engine stopped

Engine running
I
When normal

Min. 1 M 8

Max. 1 R 1. Plug
2.
0
Contact ring
Structure of circuit

202FO5 I 75

3. contact
0 The relationship between the sensor and
4. Diaphragm
the oil pressure is as follows.
5. Spring
Oil pressure above 0.7 kg/cm*:
CLOSED (ON) 6. Terminal
Oil pressure below 0.7 kg/cm2:
OPEN (OFF)

4. Engine water temperature, torque conver-


ter oil temperature sensor

1) Stop the engine, turn the starting switch


OFF, and remove the sensor from the en-
gine or torque converter.
2) Measure the resistance between terminals
1 and 2 with the sensor at about the same
temperature as the ambient temperature.

* Judgement

Ambient temperature When normal

35°C Approx. 29 KR
I I
20°C Approx. 52 KQ
I I
10°C Approx. 80 KS

1. Connector
2. Plug
3. Thermistor

I96FO2046
Structure of circuit
20-47
5. Hydraulic oil temperature sensor

1) Stop the engine, turn the starting switch


OFF.
2) With the sensor still installed to the piping
at the suction side of the hydraulic pump,
disconnect the wiring harness from the
sensor.
3) Measure the resistance between terminal
1 and the ground.

* Judgement

Condition of sensor When normal

Between terminal 1
Max. 1 Q 1. Switch
and ground I 2. Case
3. Wire
4. Connector

Structure of circuit ISSFO2047

6. Fuel level sensor

1) Stop the engine and turn the starting


switch OFF.
2) With the sensor still installed to the fuel
tank, disconnect the wiring harness from
the sensor.
3) Measure the resistance between terminals
1 and 2.

* Judgement

Condition of fuel I When normal

Full I Approx. 10 R

Empty I Approx. 85 R

F91702223

20-48