This setout is provided as a guide only. It is the responsibility of the concreter/erector to confirm that all dimensions are correct.

Purchaser Name: Justin Smith


Component Position Seller:
NOT FOR CONSTRUCTION Name: Simon Conolly
Site Address: 11 McCallum Rd Concordia SA 5118 Australia Phone: (08) 8522 2188
Not to Scale Fax: (08) 8522 4751
Page 1 of 1 Email: simon@tundarri.com.au
© Copyright Steelx IP Pty Ltd
Drawing # DG51182103015-3 Print Date: 12/04/21
338 Barossa Valley Way
KALBEEBA SA 5118
PO Box 246
GAWLER, SA 5118
Phone (08) 8522 2188
Wide Span Sheds Pty Ltd Fax (08) 8522 4751
ABN: 50 130 691 422

www.sheds.com.au

QUOTATION
Justin Smith Reference # : DG51182103015-
3
27 Window Rd Date : 12 Apr 2021
Willaston
SA, 5118
Australia

Dear Justin,

Thank you for the opportunity to quote you on your new steel building. The features and benefits of this
quotation refer to the supply of a kit only, based on the information discussed to date. Your steel building will
be manufactured locally in Adelaide, South Australia.

If you have any questions, please don't hesitate to call us.

Kind Regards,

Simon Conolly
Wide Span Sheds Sales Agent
ph: (08) 8522 2188
email: simon@tundarri.com.au

Pricing
Kit Price $33,554.55
GST $3,355.45
Delivery FREE*
Promotional Discount ($1,850.00)
TOTAL (inc GST) $35,060.00

Delivery
*Free delivery offer applies to delivery fees for the standard delivery area. Any additonal fees for delivery
outside the standard area are not included in this promotion. Conditions apply, refer to your purchase
agreement for more information.

Payment Schedule
25% initial deposit to be paid to receive all appropriate plans, engineering specifications & certificates.
25% further deposit to be paid to commence manufacturing.
50% to be paid 7 working days prior to pick up or delivery of your steel building.

www.sheds.com.au
Details of your Wide Span Sheds Building
Weight Approximately: 6,200 kg
Span 9 metres
Length 20 metres (5 Bays of 4 metres each)
Height 4 metres
Roof Type Gable, 22.5 degree pitch
Roof COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Two (2) COLORBOND® steel 3m high x 3m wide roller doors (roller door is not wind
rated). One (1) COLORBOND® steel 3.55m high x 3m wide roller door supplied with
Roller Doors a planetary gearing system (roller door is not wind rated). Refer to the General
Specification (# Access Doors) in relation to opening sizes. The Roller Doors are
boxed or steel wrapped for protection during transport. Refer to the Building
information for details on Industrial Door Handing.
One (1) 920mm wide pre-hung double skin COLORBOND® steel door with keyed
PA Doors lockset and lever handle on both sides;

Window Openings Materials to frame up for window opening(s) including a header flashing to suit One
(1) 900x1500 window (supply of the window is NOT included).
One (1) running across the span of the building. COLORBOND® steel TRIMCLAD®
Dividing Walls 0.42 BMT (0.47TCT) sheeting.

Open Bays Two (2) 4m open bays - along the sides of the steel building. Refer to Layout
(attached) for location & height clearances.
Steel building has sheeting as shown whilst the left-end-wall-mullions have been
Open Gable-Ends removed. Refer to the Layout attached.

Bracing The building will have Knee and Apex braces. Minimum internal knee clearances are:
Main Building 2.765m. Minimum internal apex clearance is: 4.919m.
One (1) bay, starting at bay Two (2). Height under joist to be 2.5m, with a
clearance under the bearer of 2.3m. Steel bearers and joists only. Bearers supported
Mezzanine by Two (2) mid columns. Stairs, balustrading and timber flooring supplied by others.
Allowable floor load is 1.5kPa uniformly distributed. (Suitable for General Storage up
to 600mm high- No concentrated loads)
Roof Purlins & Wall Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay
Girts width.
Fixing to Concrete Screw-Bolts fitted after concrete is cured.

Specific Inclusions
Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to
determine the site design wind speed based on the building orientation.
A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step,
simple to follow instructions on how to build your building.
Engineering certification of the steel building to the appropriate Australian Standards.
Slab or Pier designs for soil classes A, S, M, H1 and H2.
Materials as nominated above supplied as per the attached "General Specification".
BlueScope - product warranties of up to 15 years apply.

Specific Exclusions

www.sheds.com.au
Site Location
Site Address 11 McCallum Rd Concordia SA 5118 Australia
Building Orientation Left Side of building orientated to 317° (northwesterly direction)
Building Class 7
Importance Level 2 with a Vr of 45 m/s
Design Wind Criteria Region A1; TC = 1.0; Mt = 1.05; Ms = 1.0; giving a Vdes of 49.5 m/s.
Other Design Factors No Snow Loading allowed. No Earthquake Loading allowed.

Building Information
The design criteria nominated has been assessed by your trained sales consultant. This assessment is subject
to the certifying engineers confirmation. Final assessment by the engineer may result in a change to the
materials and price.
BlueScope and other warranties are limited to non-aggressive environments. It is the purchaser's
responsibility to ensure that they are not subject to Marine, Industrial or any other type of environmental
conditions that will limit their warranties to less than they require. Contact BlueScope on 1800 800 789.

www.sheds.com.au
General Specifications
Due to ongoing product development, the seller reserves the Fixing Method - The fixing method nominated is for the main
right to make design and engineering changes up to the point of side columns. Other columns are supplied as per engineering
commencing manufacture. The engineer's final design design. Where chemical studs are nominated, due to hazardous
requirements may override anything nominated. transport laws, the chemical is to be supplied by others. The
Standards & Codes -All buildings are designed in accordance Engineers design may override your request.
with test results, computer analysis, NCC, AS/NZS 1170, AS Marking, Cutting and Drilling - Most components are marked
3600, AS 4100 and AS 4600. for easy identification and placement. Most are also cut to length
Design Criteria - Prior to issuing engineering certification, the and drilled to suit bolt placement. It will be necessary to cut
engineer does a site specific check of the wind speed and a and/or drill some components on site.
structural design check. This design takes into account the
building orientation. Changes to the site wind speed may result in
a price increase or decrease. Unless nominated, no allowance has # symbol indicates items that are only included when
been made for earthquake or snow loading. The building is not specifically nominated in your quotation.
suitable for lining with gyprock.
Dimensions - all dimensions nominated are nominal sizes only
Length and span are to inside of sheeting. Height is to top of # Access Doors - All roller doors, sectional doors, shutters,
gutter. Length and span may vary when sides are fully open by steel sliding or bifold doors and PA doors are NOT wind rated.
up to 200mm per side/end. If an exact opening or clearance is Roller doors can be supplied wind rated at an additional cost. The
required, then this must be specifically nominated as "exact size" sizes quoted are approximate door sizes - NOT clear opening
in the quotation. sizes. Clear opening sizes may be reduced due to the building
Environmental Characteristics - All components of the steel height, widths, motors or chains. At least 70mm in height will be
building are designed to suit the conditions generally described as lost due to the 'lead in'. All roller door keys (where included) are
Non aggressive. Care must be taken with any steel building to keyed alike, unless otherwise stated. All Stable shutters will be
ensure that regular maintenance is carried out. The suitable provided in the same colour as the wall colour. Sliding doors are
conditions and Maintenance requirements are defined in the supplied so that each door will slide across the door bay plus one
various BlueScope Technical Bulletins. other bay as per shed layout.
Roof & Wall Sheeting - COLORBOND® steel or ZINCALUME® All comments regarding roller doors, sectional doors & shutters
steel as nominated. TCT refers to Total Coated Thickness. BMT are based from inside the building looking out.
refers to Base Metal Thickness. Refer to BlueScope TB-1a&1b # Colours - Not all colours are available from all manufacturing
GALVASPAN® steel Sections - GALVASPAN® steel C-sections, depots. 0.40 TCT wall sheeting has limited colours in most areas.
Z-sections, purlins and girts have a minimum coating of 350- # Delivery - Delivery is quoted to within the normal delivery
gm/m2 (Z350) and a minimum yield strength of 450Mpa. Refer runs. Additional fees apply where the address is off the run.
to BlueScope TB-17 Alternatively delivery is to be ex works. Unloading of the whole
Fasteners - All major connections including Z purlins and girts kit is not included where any length exceeds 11.8m. Semi trailer
are bolted. All other connections are tec screwed. Roof screws access required. Where a body truck is requested it is subject to
with cyclonic washers are ONLY provided where the building is availability. Should a body truck be requested and it is not
rated cyclonic. Should conditions be severe (ISO Category 4 or available for the site then the building shall be either ex works or
5), the purchaser should advise the seller of any special delivered to an alternative address by a semi trailer.
requirements. (Refer to BlueScope TB-16 and manufacturers # Dividing Walls - Sheeting to one side of the wall. Where the
warranty data.) wall is in ZINCALUME® steel, any doors etc. on the wall shall also
Bracing be in ZINCALUME® steel.
Wall & Roof : Cross and Fly bracing as per the engineering # Downpipes - 100 x 75 or 90 dia PVC as provided by our
plans, steel strapping will be supplied unless otherwise supplier.
nominated. In open bays, a double eave purlin is provided for # Ex Works - Collection will be from our supplier's depot
bracing purposes. Subject to engineering cross bracing in some nominated as the manufacturing location in the quote letter.
open bays and over windows may be required. # Insulation + Wire - Of the type nominated in the quote.
Apex: Where nominated by the engineering, apex braces are # Internal Stud Walls - No sheeting provided.
supplied. Apex braces will reduce the apex clearance height. # Mezzanine Floors - Supply is for bearers and joists only.
rafters. Flooring, stairs and balustrading are not supplied. Joist spacing a
Knee Braces: Where nominated by the engineering, lateral maximum of 600mm. Support posts fitted under bearers in line
and/or transverse knee braces are provided. Knee braces will with End Wall Mullion positions.
reduce the clearance heights. # Pricing - Pricing is valid for 30 days, unless notified of an
End Wall Mullions - Fixed at 90 degrees to the columns and impending price rise where the price rise date will become the
inside the rafter. These will reduce internal clearance. new validation date.
Gutters - The gutter type supplied will be nominated by our # Roller Door Transport Protection - All doors are either steel
supplier as the most common type for the area. wrapped or cardboard boxed to protect them during transport.
Piers and Slab - Designs are for a safe bearing value >= Any damage to a door will be accessed in accordance with the
100kPa. (400kPa ultimate). Where a concrete slab, or concrete AGDA guide to visual inspection of garage doors.
slab and piers is nominated, the wall sheeting will be supplied to # Sectional Door Transport Protection - All doors are either
extend 40 mm past the slab (building height + 40 mm). When cardboard boxed to protect them during transport. Any damage
concrete piers only are nominated, wall sheeting is provided to to a door will be accessed in accordance with the AGDA guide to
building height. Where a 50mm step down is nominated, the wall visual inspection of garage doors.
sheeting is not extended any further. # Windows - Positions shown on plans are for illustration
purposes only (all windows are 2.1m to top of window from floor
level). Windows and glass sliding doors are to be provided by
others. A header flashing is provided as part of the building.
Other stile material is provided to enable secure fixing of the
windows and surrounding sheeting. An 'X' shown in the elevation
on a window represents cross bracing over the window.

www.sheds.com.au
PO Box 453
Williamstown SA 5351
ABN: 87 689 924 574
P - (08) 85246700
M - 0419 033444
F - (08) 8524 6190
E - palmer53@bigpond.com

Quote
Barkleigh Homes
For: JUSTIN SMITH Quote No: 468
justin.smith@adbri.com.au Date: 29/03/2021

Description Quantity Rate Amount

Price to install shed 9m x 20m x 4m high. Price includes scissors lift and concrete for footings 1 $9,690.00 $9,690.00

Price to supply and fit window 900mm x 1500mm long 1 $550.00 $550.00

Price supply and install insulation to roof and walls. E-Therm. 1 $4,950.00 $4,950.00

Price to fit frame for mezzanine floor. 1 $1,000.00 $1,000.00

Subtotal $16,190.00
GST 10% $1,619.00
Total $17,809.00

Total $17,809.00