Specification for
Spray taps
UDC 621.646.6:628.156:696.117
BS 5388:1976
Cooperating organizations
Contents
Page
Cooperating organizations Inside front cover
Foreword ii
Section 1. General
1 Scope 1
2 References 1
3 Definitions 1
4 Nominal size 1
5 Marking 1
Section 2. Dimensions, design and construction
6 General 1
7 Dimensions 1
8 Materials 1
9 Spray outlet 2
10 Flow restrictor 2
Section 3. Testing
11 General 3
12 Rate of flow test 3
13 Test for divergence of the spray 3
Appendix A Information to be supplied by the purchaser 6
Appendix B Method of measuring the rate of flow through
spray taps fitted with a fixed flow restrictor 6
Appendix C Method of measuring the rate of flow through spray
taps fitted with an adjustable or self adjusting flow restrictor 6
Appendix D Method of measuring the divergence of the spray 7
Appendix E Design considerations for wash basins and troughs
fitted with spray taps 7
Appendix F Notes on the installation of spray taps 7
Figure 1 — Installation and dimensional features of pillar
spray taps 2
Figure 2 — Installation and dimensional features of bib
spray taps 2
Figure 3 — Diagram of rate of flow test apparatus 3
Figure 4 — Details of pressure take-off tee 4
Figure 5 — Sectional diagram of spray, spray outlet and
annular gauge 5
Table 1 — Working pressure ranges and test pressures for
fixed flow restrictors 2
Table 2 — Dimensions of pressure take-off tee 4
Publications referred to Inside back cover
© BSI 12-1999 i
BS 5388:1976
Foreword
This British Standard has been prepared under the authority of the Sanitary
Appliances Standards Committee and at the request of the Department of the
Environment and The Building Research Establishment.
Spray taps provide a quick, hygienic method of washing under running water.
The use of spray taps appreciably reduces the total amount of water used for
handwashing.
Spray “mixing” taps, which incorporate a mixing function operated by the user,
are not specified in this standard, but it is intended to prepare a separate British
Standard dealing with them. They possess characteristics similar to those of
spray taps but they are also able to accept hot and cold water supplies and mix
them for delivery at a temperature to suit the user.
The factors governing the use of spray taps, and their associated plumbing
systems, are numerous. Pending the inclusion of a statement on design
considerations in the relevant British Standard codes of practice, and the issue of
British Standard specifications for special wash basins and troughs for spray
taps, Appendix E and Appendix F to this present standard set out some basic
considerations.
A British Standard does not purport to include all the necessary provisions of a
contract. Users of British Standards are responsible for their correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.
Summary of pages
This document comprises a front cover, an inside front cover, pages i and ii,
pages 1 to 8, an inside back cover and a back cover.
This standard has been updated (see copyright date) and may have had
amendments incorporated. This will be indicated in the amendment table on the
inside front cover.
ii © BSI 12-1999
BS 5388:1976
© BSI 12-1999 1
BS 5388:1976
9 Spray outlet
The spray tap shall be provided with a spray outlet
capable of causing the water to assume the shape of
a diverging spray. The cone shall not diverge to an
extent greater than that shown in Figure 5 when
the tap is fully opened.
Every waterway in the outlet shall be capable of
accepting a 1 mm nominal diameter steel probe and
the steel shall comply with the requirements of
BS 1407.
The spray outlet device shall be capable of being
removed for cleaning but only by the use of a special
tool.
10 Flow restrictor
A flow restrictor shall be provided in the spray tap.
The flow restrictor may be either adjustable or one NOTE 1 Drawing is diagrammatic only.
NOTE 2 Dimensions in “box” are given for guidance only.
of the three fixed flow types, the pressure limits for
which are specified in Table 1. Self adjusting flow Figure 1 — Installation and dimensional
restrictors may also be used provided that not more features of pillar spray taps
than two patterns are required to satisfy the
requirements of 12.2 over the whole range of
working pressures set out in Table 1.
The flow restrictor shall be in a form so that it can
be adjusted or changed without removing the tap
from the wash basin, but cannot be so adjusted
without the use of a special tool.
Table 1 — Working pressure ranges and test
pressures for fixed flow restrictors
BS flow restrictor Working pressure range Test flow
number min. max. pressure
bara bar
2 © BSI 12-1999
BS 5388:1976
© BSI 12-1999 3
BS 5388:1976
4 © BSI 12-1999
BS 5388:1976
© BSI 12-1999 5
BS 5388:1976
Appendix A Information to be With the stopvalve fully open, and the spray tap
supplied by the purchaser closed, adjust the supply pressure to the test
pressure specified in Table 1 for number 1 flow
The purchaser shall supply the following restrictors. Open the spray tap by rotating its hand
information when making an enquiry or placing an control through 180° from the commencement of
order: flow. Record the rate of flow. Open the spray tap
a) the nominal size of the spray tap, fully. Record the rate of flow.
i.e. " nominal size; Repeat the procedure with number 2 and number 3
b) whether a bib type mounting or a pillar type flow restrictors installed in the spray tap and using
mounting is required; the appropriate test pressures specified in Table 1.
c) whether a rising or non-rising spindle is B.4 Recording
required; Record whether or not each combination of spray
d) the working pressure (bar) to which the spray tap and fixed restrictor will deliver water at the
tap will be subjected (see Table 1); specified rates.
e) the type of flow restrictor.
Appendix C Method of measuring the
Appendix B Method of measuring the rate of flow through spray taps fitted
rate of flow through spray taps fitted with an adjustable or self adjusting
with a fixed flow restrictor flow restrictor
B.1 Object C.1 Object
The object of the test is to determine whether or not The object of the test is to determine whether or not
the specimen spray tap will deliver water at the the specimen spray tap will deliver water at the
specified rates. specified rates.
B.2 Apparatus C.2 Apparatus
The following are required. The apparatus shall be as specified in B.2.
B.2.1 A water supply having a minimum pressure C.3 Procedure
of 4.50 bar and a minimum rate of flow, when the Connect the apparatus to the water supply. Connect
supply pipe is open to atmosphere, of 0.10 litre/s. the spray tap to the apparatus.
B.2.2 A stopvalve With the stopvalve fully open, and the spray tap
B.2.3 A pressure regulator capable of reducing the closed, adjust the pressure regulator to give a
supply pressure to the test pressures required. supply pressure of 0.27 bar. Open the spray tap by
B.2.4 A flowmeter, graduated in ml/s and accurate rotating its hand control 180° from the
to ± 2 %. commencement of flow.
B.2.5 A pressure gauge, graduated in bar and Adjust the flow restrictor until the rate of flow
accurate to ± 2 %. specified in 12.2 is achieved. Record the rate of flow.
Open spray tap fully. Record the rate of flow.
B.2.6 A copper tube of 15 mm outside diameter in
accordance with BS 2871-1. Repeat the above procedure using a supply pressure
of 3 bar.
B.2.7 Fittings necessary to complete the test
apparatus shown in Figure 3. The bore of any fitting C.4 Recording
shall be at least equal to the bore of the copper tube Record whether or not the spray tap, with the
(see B.2.6) used in the apparatus to avoid adjusted restrictor, will deliver water at the
constriction of the waterway. specified rates.
B.3 Procedure
Connect the apparatus to the water supply. Install
the number 1 restrictor in the spray tap. Connect
the spray tap to the test apparatus.
6 © BSI 12-1999
BS 5388:1976
Appendix D Method of measuring the E.2 Attention is drawn to Model Water Byelaw 52
divergence of the spray which requires that wash basins and troughs used
in association with spray taps shall be fitted with a
D.1 Object plug waste except where a spray tap is so designed
The object of the test is to determine whether or not and arranged that it cannot deliver water at a rate
the specimen spray tap will deliver a spray of exceeding 5 pints/min in which case they may be
specified requirements. fitted with a waste that will not accept a plug. Such
D.2 Apparatus appliances do not require an overflow.
The apparatus shall be as specified in B.2, together E.3 The discharge from properly adjusted spray
with a gauge as shown in Figure 5. taps should be contained within the sanitary
appliances that they serve.
D.3 Procedure
E.4 It should be possible to place the hands in the
Connect the rate of flow test apparatus to the water
water spray without obstruction or without
supply. Connect the spray tap to the rate of flow test
requiring undue manipulation of the hands.
apparatus.
Open the spray tap by rotating the hand Appendix F Notes on the installation
control 180° from the commencement of flow. Adjust of spray taps
the stopvalve to give a steady rate of flow
of 0.03 litre/s. Place the gauge as shown in Figure 5. F.1 Spray taps should normally be fed with water at
Centralize as required. Allow the water to flow for a a temperature between 38 °C and 43 °C. For special
minimum of 60 s before commencing observations. circumstances, this range may need to be varied.
Repeat the procedure using a rate of flow F.2 It is desirable that a strainer be installed in the
of 0.05 litre/s. supply pipe to each single tap or group of taps.
D.4 Recording F.3 It should be accepted that the spray outlet will
Record the volume of water that has entered the need cleaning at intervals, the length of the
intervals depending on the water supply.
outer annulus, the four sections of the inner
annulus and the central cylinder. F.4 The blended water circulating system should be
taken close to the spray tap, and the diameter and
Appendix E Design considerations for length of dead legs kept to an absolute minimum.
wash basins and troughs fitted with
spray taps
E.1 Pending the issue of a British Standard for wash
basins and troughs for spray washing the
recommendations in this appendix are given for
guidance.
© BSI 12-1999 7
8 blank
BS 5388:1976
Publications referred to
BS 864, Capillary and compression tube fittings of copper and copper alloys.
BS 864-2, Metric units.
BS 970, Wrought steels in the form of blooms, billets, bars and forgings.
BS 970-4, Stainless, heat resisting and valve steels.
BS 1010, Draw-off taps and stopvalves for water services (screwdown pattern).
BS 1010-1, Imperial units.
BS 1010-2, Draw-off taps and above ground stopvalves.
BS 1407, High carbon bright steel (silver steel).
BS 2779, Pipe threads where pressure-tight joints are not made on the threads.
BS 2871, Copper and copper alloys. Tubes.
BS 2871-1, Copper tubes for water, gas and sanitation.
BS 3457, Materials for water tap and stopvalve seat washers.
BS 4118, Glossary of sanitation terms.
BS 5412, Specification for the performance of draw-off taps with metal bodies for water services1).
BS 5412-1, Dimensional and design characteristics.
1)
In course of preparation. Because of the similarity in requirements for the BS 5412 and BS 5413 series, these standards are
published under one cover, i.e. BS 5412-1 and BS 5413-1 comprise one publication, and similarly for the other Parts.
© BSI 12-1999
BS 5388:1976
Revisions
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover.
Tel: 020 8996 9000. Fax: 020 8996 7400.
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001.
Information on standards
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written
permission from BSI.
This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.