Annual Production Report

Humayun Sab office, C48F+FWV FAISALBAD


 Report  System Metrics  Project Location

Project Name HumayunSab. Design Humayun Sab

Project Address C48F+FWV FAISALBAD Module DC


8.88 kW
Nameplate

Prepared By Omecta International Pvt/ Ltd. Inverter AC 5.00 kW


Nameplate Load Ratio: 1.78

Annual
12.84 MWh
Production

Performance
73.0%
Ratio

kWh/kWp 1,445.9

Weather TMY, 10km Grid, meteonorm/suny high


Dataset resolution (meteonorm)

Simulator 0adba856a3-9c76e33ff0-441925c571-
Version dcd201090c

 Monthly Production  Sources of System Loss

1500
AC System:
System: 0.5% Shading: 0.7%
Shading:

Inverters: 2.3%
Inverters: Reflection: 3.3%
Reflection:
Clipping: 3.1%
Clipping: Soiling: 2.0%
Soiling:
1000
Wiring: 0.3%
Wiring: Irradiance: 0.3%
Irradiance:
kWh

500 Mismatch: 4.8%


Mismatch:

0 Temperature: 13.0%
Temperature:
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

GHI POA Shaded Nameplate Grid


Month
(kWh/m2) (kWh/m2) (kWh/m2) (kWh) (kWh)
January 87.6 98.0 97.2 810.5 700.1
February 116.1 127.2 126.2 1,058.8 874.8
March 163.0 173.9 172.7 1,454.8 1,131.3
April 182.5 186.8 185.7 1,567.3 1,183.9
May 217.6 218.5 217.1 1,835.8 1,333.9
June 209.6 208.9 207.5 1,753.5 1,298.7
July 206.4 207.4 206.0 1,738.6 1,308.2
August 188.2 191.8 190.8 1,610.4 1,222.4
September 167.8 176.6 175.6 1,482.3 1,137.5
October 147.2 160.7 159.6 1,344.6 1,059.8
November 109.9 125.0 123.8 1,035.9 857.5
December 90.6 105.1 103.8 865.4 731.1

© 2023 Aurora Solar 1/3 May 20, 2023


Annual Production Report

 Annual Production  Condition Set


Description Output % Delta Description Condition Set 1
Annual Global Horizontal Irradiance 1,886.6 Weather Dataset TMY, 10km Grid, meteonorm/suny high resolution (meteonorm)
POA Irradiance 1,979.8 4.9%
Solar Angle Location Meteo Lat/Lng
Irradiance Shaded Irradiance 1,966.0 -0.7%
(kWh/m2) Transposition Model Perez Model
Irradiance after Reflection 1,901.2 -3.3%
Irradiance after Soiling 1,863.2 -2.0% Temperature Model Sandia Model
Total Collector Irradiance 1,863.3 0.0% Rack Type a b Temperature Delta
Nameplate 16,557.9 Fixed Tilt -3.56 -0.075 3°C
Output at Irradiance Levels 16,505.7 -0.3% Temperature Model
Parameters Flush Mount -2.81 -0.0455 0°C
Output at Cell Temperature Derate 14,363.9 -13.0% East-West -3.56 -0.075 3°C
Energy Output After Mismatch 13,676.6 -4.8% Carport -3.56 -0.075 3°C
(kWh) Optimal DC Output 13,631.5 -0.3%
J F M A M J J A S O N D
Constrained DC Output 13,203.6 -3.1% Soiling (%)
2 2 2 2 2 2 2 2 2 2 2 2
Inverter Output 12,903.7 -2.3%
Irradiation Variance 5%
Energy to Grid 12,839.2 -0.5%
Temperature Metrics Cell Temperature Spread 4° C

Avg. Operating Ambient Temp 26.8 °C Module Binning Range -2.5% to 2.5%
Avg. Operating Cell Temp 48.9 °C AC System Derate 0.50%
Simulation Metrics Uploaded
Module Characterization
Operating Hours 4552 Module By
Characterizations LR5-72HPH-555M (2022) Spec Sheet
Solved Hours 4552
HelioScope
(Longi) Characterization, PAN
Component Device Uploaded By Characterization
Characterizations X3-MIC-5K-G2 (400V) (Solax) HelioScope Spec Sheet

 Components  Wiring Zones

Component Name Count Description Combiner Poles String Size Stringing Strategy
1 (5.00 Wiring Zone - 3-18 Along Racking
Inverters X3-MIC-5K-G2 (400V) (Solax)
kW)
Strings 10 AWG (Copper) 1 (7.9 ft)
 Field Segments
Longi, LR5-72HPH-555M (2022) 16 (8.88
Module Intrarow Frame
(555W) kW) Description Racking Orientation Tilt Azimuth Frames Modules Power
Spacing Size
Field Segment Flush Landscape 4.44
10° 221° 0.2 ft 1x1 8 8
1 Mount (Horizontal) kW
Field Segment Flush Landscape 4.44
10° 223° 0.2 ft 1x1 8 8
2 Mount (Horizontal) kW

© 2023 Aurora Solar 2/3 May 20, 2023


Annual Production Report

 Detailed Layout

© 2023 Aurora Solar 3/3 May 20, 2023