GE Intelligent Platforms Drivers

The Features and Benefits of


Proficy* HMI/SCADA iFIX* Driver
Technology

* Trademark of GE Intelligent Platforms, Inc.


All other brands or names are property of their respective holders.
Proficy HMI/SCADA iFIX I/O Drivers
Purpose of an I/O Driver
• Software Interface between Plant Floor Hardware
(PLC) and HMI/SCADA database
• Provides real-time data to the HMI/SCADA process
database, Graphics, and Historian
• Offer both high performance proprietary format and
supports
an Open Standard (OPC – OLE for Process Control)
What is an HMI/SCADA without a Quality Driver?
• Just a graphics package!

2/
GE Title or job number /
10/19/23
What Customers desire from I/O
Drivers?
Flexible Solutions
• Drivers that can handle any application

Open Solutions
• Support for Industry Standards
• Toolkits for Custom Drivers

Provide Easy Delivery Methods


• CD with Product Purchases
• Website for Product Updates and Enhancements

3/
GE Title or job number /
10/19/23
Ease of Use
Develop Easy-to-Use Products (Starting with the CD)
• Getting Started Guide on Driver CD (‘Drivers for Dummies’)
• Configuration in all 7.x drivers is via the “Power Tool”
• Digitized Pictures of H/W embedded in eDOC

4/
GE Title or job number /
10/19/23
Proficy HMI/SCADA iFIX I/O Drivers -
Features & Benefits
FEATURE BENEFIT
Functions as a High Performance Driver Multi-purpose implementation in one
& an OPC Server product
‘On the fly’ configuration Faster implementation – no need to
start/re-start due to configuration changes
Digital Photos of hardware setup
Easier hardware setup & enhanced
HTML help system
troubleshooting
DataMonitor & DataScope
Easier to use help system
Templates & Report Files
Decreased configuration time
Redundant Communications
High reliability in the most demanding
applications
5/
GE Title or job number /
10/19/23
IGS – Universal Driver

6/
GE Title or job number /
10/19/23
Industrial Gateway Server (IGS) 7.5
Powering connectivity to drive results

• Over 70+ proven and reliable protocols


• Device connectivity solutions for all Proficy
Products
• Enhanced interface, easy administration, on the
fly updating
• Basic 75 tag, Basic Unlimited, Premium or
SNMP packages
• IGS Basic Unlimited now included in iFIX 5.5
Value
• Enables a wide range of devices and
manufactures
• Ability to run many different protocols and
devices simultaneously from 1 instance
• Ability to have multiple OPC clients connect to a
7/
single point GE Title or job number /
10/19/23
Industrial Gateway Server (IGS) 7.53
OPC UA Tunneling

8/
GE Title or job number /
10/19/23
Smart Drivers – IEC 61850

9/
GE Title or job number /
10/19/23
Proficy IEC 61850 Client
Driver Option for Power Industry
A standard for the design
of electrical substation automation
• Part of the International Electrotechnical Commission's
(IEC), (TC57) Reference architecture for electric power Native OPC-DA
IEC
systems.
• TC 57 responsible for the development of standards for
information exchange for power systems and other related
systems including Energy Management Systems, SCADA, TC57
distribution automation & teleprotection
• IEC 61850 is a TC57 publication: “Communication
networks and systems in substations / for power utility Configuration, Tags, Types, etc.
automation” IEC
61850

The 61850 Object Model

10 /
GE Title or job number /
10/19/23
Legacy Drivers

11 /
GE Title or job number /
10/19/23
Driver Configuration – The “Power Tool”

And direct access to help system


Includes Special Tips

12 /
GE Title or job number /
10/19/23
Troubleshooting – Driver Statistics Mode
•Provides overall view of
System health (at Driver level,
in this case - GE9)
•Can be viewed at various
levels
•Channel
•Device
•Datablock (shown at left)

13 /
GE Title or job number /
10/19/23
Troubleshooting – The Data Monitor

•Displays Data from a given


datablock
•Last Read Time
•Last Write Time
•Time for last error

Users can choose


desired display format

14 /
GE Title or job number /
10/19/23
Troubleshooting – The DataScope

• Eliminates need for


external DataScope
hardware
• Provides ability to see
characters being transmitted
in a message (in hex or ascii
format)

15 /
GE Title or job number /
10/19/23
Time Saving Configuration Tools
Starter Templates
• Set default values (Channel, Device & Datablock)
• Default values used when configuring from Power Tool or from Database Manager

CSV File Support


• Useful for off-line editing and importing

AutoCreate from Proficy HMI/SCADA iFIX Database (One Step Configuration)


• Create Channels & Devices in the Power Tool
• Datablocks are created based upon I/O address configuration in the Process Database

16 /
GE Title or job number /
10/19/23
Corporate Driver History

A Leader in I/O Driver connectivity


Driver technology has evolved over the years, but some
things remain forever important
• High Performance
• Extreme Data Integrity
• Ease of Use
• Ability to respond to changing market requirements
• Ease of maintenance
• Long term support
17 /