Professional Documents
Culture Documents
DSUSMTK11171101 HEALIX With PERMATAPE Brochure
DSUSMTK11171101 HEALIX With PERMATAPE Brochure
76% less abrasive than FiberTape1 12% more contact area with Compatible with EXPRESSEW® III
30-cycle test with 15N load 54% less bulk as compared AutoCapture+ Flexible Suture Passer
to FiberTape1
• Greater torque strength that allows for punch-only insertion in a variety of bone densities*2
• Promotes bone growth formation at the implant site with the BIOCRYL RAPIDE® Biocomposite Material option3
• Secure fixation demonstrated through high pullout strength4
• Cannulated to channel blood flow to surface
Turns to Insertion6
10
Anchor
Anchor Fixation
Fixation Strength
Strength Average (N)2 (N)5
Average 8
Healicoil
1. Insert two PERMATAPE Suture 2. Pass the tail of the utility suture 3. Retrieve the tail end of the utility
anchors medially through one or through the posterior cuff using shuttle suture out an anterior
more stab incisions EXPRESSEW® III Flexible Suture portal
Passer via the lateral portal
4. Retrieve anterior PERMATAPE 5. Pull the utility suture tail to shuttle 6. Repeat steps 2-5 with the
Sutures to the lateral portal and multiple sutures through a single posterior sutures
load both tails into the loop of point #2 sutures may be removed at
the utility suture any point if they will not be used
References
1. Internal test reports 103288856, 103313374 and 103313375
2. Internal test reports DVE-002466-DVR Rev C, DVE-002626-DVR Rev B and RR-101228-R Rev B
3. Barber, FA, et al. “Biocomposite Implants Composed of Poly (Lactide-co-Glycolide)/β-Tricalcium Phosphate: Systematic Review of Imaging, Complication, and
Performance Outcomes.” Arthroscopy;33(3):683-689.
4. Barber FA, Herbert MA, Beavis RC, Barrera Oro FB. Suture anchor materials, eyelets, and designs: update 2008. Arthroscopy. 2008;24(8):859-867.
5. Internal test reports 103329780 and RR-101380-R
6. Internal report 103426879
Limited Warranty and Disclaimer: DePuy Synthes Mitek Sports Medicine products are sold with a limited warranty to the original purchaser against defects in
workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed.
WARNING: Please also refer to the package insert(s) or other labeling associated with the devices identified in this brochure for additional information.
CAUTION: USA Law restricts these devices to sale by or on the order of a physician.
Not all products are currently available in all markets. The third party trademarks used herein are the trademarks of their respective owners.
US Representative:
www.depuysynthes.com Medos International SÀRL DePuy Mitek, Inc.
Chemin-Blanc 38 325 Paramount Drive
© DePuy Synthes 2017. All rights reserved.
CH-2400 Le Locle Raynham, MA 02767
DSUS/MTK/1117/1101 11/17 Switzerland T. +1 (800) 382-4682