H Series - Instrumentation
Data Loggers, Handhelds, Indicators, Infrared Pyrometers, H
Recorders, and Temperature Controllers, 1/8, 1/4 DIN
I Series - RTDs
Sensors with leads, plugs, and conduit heads
I
K Series - Feed-Thrus
Thermocouple and Instrumentation, Vacuum & High Pressure
K
Specifications
Adaptor
Length Length
Part No. Model Part No. Model
“A” (in.) “A” (in.)
A5-1 2 A5-19 2
A5-2 2-1/2 A5-20 2-1/2
A5-3 3 A5-21 3
A5-4 3-1/2 A5-22 3-1/2
A5-5 00 4 A5-23 90 4
A5-6 4-1/2 A5-24 4-1/2
A5-7 5 A5-25 5
A5-8 5-1/2 A5-26 5-1/2
A5-9 6 A5-27 6
A5-10 2
A5-11 2-1/2
Instructions for A5-12 3
Hole Depth and Adaptors A5-13 3-1/2
A5-14 45 4
Length “A” Specify thermocouple calibration
Depth A5-15 4-1/2
“B” (in.) 7/8” long 1-3/8” long 2-1/2” long A5-16 5
Adaptor Adaptor Adaptor A5-17 5-1/2 All standard units have 36” armored
A5-18 6 extension leads.
1/2 to 1 2 2-1/2 3-5/8
1 to 1-1/2 2-1/2 3 4-1/2 Mounting Adaptors All bayonet thermocouples are
1-1/2 to 2 3 3-1/2 4-5/8 supplied without adaptors and
A5-28 7/8
2 to 2-1/2 3-1/2 4 5-1/8 connectors.
A5-29 1/8 NPT 1-3/8
2-1/2 to 3 4 4-1/2 5-5/8
A5-30 2-1/2
3 to 3-1/2 4-1/2 5 6-1/8
3-1/2 to 4 5 5-1/2 6-5/8 A5-31 7/8
4 to 4-1/2 5-1/2 6 7-1/8 A5-32 3/8-24 NF 1-3/8
4-1/2 to 5 6 6-1/2 7-5/8 A5-33 2-1/2
NOTES:
• Spring or armor adjustable provide wide
versatility • Longer lengths are available
• Fiberglass insulation offers protection to the • When ordering, specify style & type
wire Example: A5A-10-J, for type J
Specifications
Part No. Style Lead Wire Terminations
A5A-10 Bayonet cap on 8” spring 60” length Stripped wires 3” long
A5A-15 Bayonet cap on 12” spring 60” length Stripped wires 3” long
A5A-20 Bayonet cap on flexible armor 60” length Male thermocouple connector
Washer thermocouples are designed to measure true average temperature of the washer.
Conduction errors are minimized by welding the thermocouple elements at 180 degrees.
NOTES:
• If lead lengths longer than 36 inches are
• Similar units are available using split lock required, specify your length requirement.
washers.
• Standard insulation material is fiberglass
• Termination styles: bare wire, standard size, (which is good to 900 degrees
or mini connectors are available. Fahrenheit operation).
Specifications
Washer Washer
Part No. Type Part No. Type
ID (in.) OD (in.) ID (in.) OD (in.)
A6-1 J 1/8 5/16 A6-11 K 1/8 5/16
A6-2 J 3/16 7/16 A6-12 K 3/16 7/16
A6-3 J 1/4 5/8 A6-13 K 1/4 5/8
A6-4 J 3/8 7/8 A6-14 K 3/8 7/8
A6-5 J 1/2 1-1/4 A6-15 K 1/2 1-1/4
A6-6 T 1/8 5/16 A6-16 E 1/8 5/16
A6-7 T 3/16 7/16 A6-17 E 3/16 7/16
A6-8 T 1/4 5/8 A6-18 E 1/4 5/8
A6-9 T 3/8 7/8 A6-19 E 3/8 7/8
A6-10 T 1/2 1-1/4 A6-20 E 1/2 1-1/4
Length Length
Part No. Model Part No. Model
“A” (in.) “A” (in.)
A6A-1 00 2 A6A-19 90 2
A6A-2 00 2-1/2 A6A-20 90 2-1/2
A6A-3 00 3 A6A-21 90 3
A6A-4 00 3-1/2 A6A-22 90 3-1/2
A6A-5 00 4 A6A-23 90 2
A6A-6 00 4-1/2 A6A-24 90 2-1/2
A6A-7 00 5 A6A-25 90 3 Length “A”
A6A-8 00 5-1/2 A6A-26 90 3-1/2 Depth
“B” (in.) 7/8” long 1-3/8” long 2-1/2” long
A6A-9 00 6 A6A-27 90 6
Adaptor Adaptor Adaptor
A6A-10 45 2
1/2 to 1 2 2-1/2 3-5/8
A6A-11 45 2-1/2 Specify thermocouple calibration
1 to 1-1/2 2-1/2 3 4-1/2
A6A-12 45 3
1-1/2 to 2 3 3-1/2 4-5/8
A6A-13 45 3-1/2 All standard units have 36” armored
2 to 2-1/2 3-1/2 4 5-1/8
extension leads.
A6A-14 45 4 2-1/2 to 3 4 4-1/2 5-5/8
A6A-15 45 4-1/2
All bayonet thermocouples are 3 to 3-1/2 4-1/2 5 6-1/8
A6A-16 45 5
supplied without adaptors and 3-1/2 to 4 5 5-1/2 6-5/8
A6A-17 45 5-1/2
connectors. 4 to 4-1/2 5-1/2 6 7-1/8
A6A-18 45 6 4-1/2 to 5 6 6-1/2 7-5/8
Monitor the temperature of semisoft materials such as: tires, plastics, food, etc.
Specifications
Part No. Type
A6B-30 K
The Bolt-Down Thermocouple contains #20 gauge (0.032”) solid conductors with fiberglass
insulation over each leg and fiberglass insulation overall. The fiberglass insulation has a
maximum service temperature of 900 degrees Fahrenheit. The ‘Bolt-Down’ thermocouple
is ideal for bolting it to a wall. Four standard sizes are available (#6, #8, #10, and #1/4”
eyelets). In addition to bolting the thermocouple to a wall, it can also be hooked to a traveling
conveyor or hung from a ceiling or hook.
NOTES:
• Standard lengths are 36 inches (longer
• Fiberglass insulation is standard. lengths available upon request).
• Bolt-Down thermocouples available in four • Choose from termination styles: bare leads,
standard thermocouple types J, T, K, and E. 2-pole connector, or spade plugs.
A7 A B C D E F
Type Insulation Stainless Steel Length Termination Eyelet
Overbraid
1=J 1 = Fiberglass 1 = None 1 = Grounded 1 = Bare Leads A = #6 (.145”)
2=K 2 = Teflon 2 = Yes 2 = Ungrounded 2 = Stand Plug B = #8 (.170”)
3=T 3 = Nextel 3 = Spade Lugs C = #10 (.195”)
4=E 4 = Mini Plug D = 1/4 (.290”)
When ordering, specify Part No. and fill in the 4 letter blocks
Example: A14A-2-20-K-24 (specifies a Style 2 duplex thermocouple with 20 gauge Type K elements and length of 24 inches.
Probes can be supplied spring loaded or with fixed mounted fittings. All fittings are 304
stainless steel with 1/2 inch NPT for mounting into: walls, connector heads, or thermowells.
The (SL - spring loaded) units allow up to 3/4 inch of travel. The (W - welded) units have the
1/2 inch NPT fitting brazed to the probe. All replacement units are supplied with one inch of
bare leads.
• Keep in mind that either Spring-Loaded (SL) or
NOTES: Welded (W) bushings utilize approximately two
inches of the sheath length. Please account for
• Duplex junctions units are available on this when specifying length.
all models except 1/16 inch diameter
units. Contact factory for more • PFA Teflon® encapsulation - good to 450°F, can
information. be added to any probe.
This thermocouple probe comes with the appropriate, color coded, male connector
attached and the female connector (not shown) furnished with a cable clamp. Maximum
service temperature of connectors is 450 degrees Fahrenheit. If other connectors are
required, contact the factory.
NOTES: • High temperature (800 degrees Fahrenheit) standard
connectors and miniature plugs & jacks also available
• Duplex and multiple units also
available, contact factory. • PFA Teflon® encapsulation - good to 450°F, can be
added to any probe.
These thermocouples are available with either stainless steel or inconel sheaths. Fitted
with a transition from the sheath to 36 inches of fiberglass insulated (insulation code 828)
flexible leads. Available in thermocouple types E, J, K, and T as a standard assembly. Other
thermocouple calibrations as well as various lead wire insulation materials are available
upon request.
These thermocouples are available with either stainless steel or inconel sheaths. Fitted
with a transition from the sheath to 36 inches of fiberglass insulated flexible leads which
are enclosed within stainless steel armor for use in rugged applications. These units are
available in thermocouple types E, J, K, and T as a standard assembly. Other thermocouple
calibrations as well as various lead wire insulation materials are available upon request.
Maximum service temperature of the transition adaptor 400 degrees Fahrenheit. Maximum
use temperature of the thermocouple is determined by considering the sheath material
being used and the thermocouple calibration. Standard units are 12 inches long, units can
be made as short as 1-1/2 inches long without any special consideration.
NOTES: • Duplex units are available on units larger than
0.062” contact factory with your particular
• Various adjustable compression fittings requirement.
and mounting bushings are available for
these units. • Lead lengths other than 36 inches, and lead wire
insulations other than fiberglass are available.
• Both standard size and miniature plugs
and jacks are also available. • PFA Teflon® encapsulation - good to 450°F, can
be added to any probe.
The construction of this thermocouple is a one piece design which does not utilize any
transition fitting. Advantages of this construction are no splices from thermocouple to lead
wire and no transition adaptors having a diameter greater than the thermocouple sheath.
Units can therefore be mounted from the inside out of a chamber, pushed into a drilled hole,
etc.
• Duplex units are available on various
NOTES: units, contact factory with your particular
requirement.
• Various adjustable compression fittings and
mounting bushings are available for these • Lead lengths other than 36 inches, and lead
units. wire insulations other than fiberglass are
available.
• Both standard size and miniature plugs and
jacks are also available. • PFA Teflon® encapsulation - good to 450°F,
can be added to any probe.
If you require that unit can be bent, contact factory for more information.
Thermocouple calibration
type N is available in all sizes.
Specifications
Sheath Sheath
Part No.
Diameter (in.) Material
A8E-1 0.062 SS 304
A8E-2 0.125 SS 304
A8E-3 0.187 SS 304
A8E-4 0.250 SS 304
A8E-5 0.062 Inconel 600
A8E-6 0.125 Inconel 600
A8E-7 0.187 Inconel 600
A8E-8 0.250 Inconel 600
A8E-9 0.187 Quartz
A8E-10 0.250 Quartz
A8E-11 0.375 Quartz
A8E-12 0.187 Al2O3 - 99.5%
A8E-13 0.250 Al2O3 - 99.5%
A8E-14 0.375 Al2O3 - 99.5%
Our Thermocouple Extension Assemblies feature #20 gage fiberglass insulated wire
with flexible stainless steel armor. Solid #20 gage thermocouple grade wires are used for
thermocouple types E, J, K, and T. Extension grade #20 gage solid wires are used for types
Rx, Sx, Bx, and Cx thermocouples. Other insulation types are available, contact factory with
your specify requirement (standard length “Y” is 36 inches ±1 inch).
Specify Part No. and length (Example: A8H-1-36 specifies type J, and 36 inches long).
Thermocouple calibration type N is available in all sizes.
Specifications
Dimension Drawings
Part No. Type
Single A8H-1 J
A8H-2 K
A8H-3 E
A8H-4 T
A8H-5 R/S/B
A8H-6 C
Single A8H-7 J
A8H-8 K
A8H-9 E
A8H-10 T
A8H-11 R/S/B
A8H-12 C
Single A8H-13 J
A8H-14 K
A8H-15 E
A8H-16 T
A8H-17 R/S/B
A8H-18 C
Duplex A8H-19 J
A8H-20 K
A8H-21 E
A8H-22 T
A8H-23 R/S/B
A8H-24 C
Duplex A8H-25 J
A8H-26 K
A8H-27 E
A8H-28 T
A8H-29 R/S/B
A8H-30 C
Duplex A8H-31 J
A8H-32 K
A8H-33 E
A8H-34 T
A8H-35 R/S/B
A8H-36 C
Our RTD cable assemblies feature either fiberglass (FIB) insulation rated at 900 degrees
Fahrenheit or teflon (TEF) insulation rated at 400 degrees Fahrenheit. Available in two, three,
or four conductors. The standard plugs and jacks are rated to a continuous 400 degrees
Fahrenheit.
NOTES:
• For (HT - high temperature) plugs and jacks • Custom design units are available; contact
rated to 800 degrees Fahrenheit, specify by the factory with your specific requirement.
adding the suffix HT.
• When ordering, specify part number and
• Standard “Y” length is 36 inches ±1 inch; if length. Example: A8H-RTD-31-72 specifies
your length requirement is different, please a 3 wire fiberglass insulated assembly with
specify. The pigtails use teflon shrink standard plug and jack, 72 inches long.
tubing.
Specifications
Number
Dimension Drawings Part No. Type
of Wires
A8H-RTD-10 2 FIB
A8H-RTD-11 3 FIB
A8H-RTD-12 4 FIB
A8H-RTD-13 2 TEF
A8H-RTD-14 3 TEF
A8H-RTD-15 4 TEF
A8H-RTD-20 2 FIB
A8H-RTD-21 3 FIB
A8H-RTD-22 4 FIB
A8H-RTD-23 2 TEF
A8H-RTD-24 3 TEF
A8H-RTD-25 4 TEF
A8H-RTD-30 2 FIB
A8H-RTD-31 3 FIB
A8H-RTD-32 4 FIB
A8H-RTD-33 2 TEF
A8H-RTD-34 3 TEF
A8H-RTD-35 4 TEF
Illustrations Specifications
Plain End
Style 1
One Inch Bare Leads
Pipe Thread Fitting Style - Specifications Both styles are available for probe
Tube Male diameters from 1/16” to 1.0” OD.
Part No. OD Pipe Size A B C (other sizes upon request). The O-ring
T P
style is also ideal for use in thin-wall
A10-1 1/16 1/16 15/16 3/8 7/16
A10-2 1/16 1/8 1 3/8 7/16 applications, glass containers, jar lids,
A10-3 1/8 1/8 1-3/16 3/8 5/8 etc. Simply put a jam nut on other
A10-4 3/16 1/8 1-15/64 3/8 21/32
A10-4A 3/16 1/4 1-5/16 9/16 23/32 side of container lid.
A10-5 1/4 1/8 1-5/16 3/8 23/32
A10-6 1/4 1/4 1-1/2 9/16 23/32 NOTES:
A10-7 1/4 3/8 1-17/32 9/16 23/32 • If a (BR - brass) adjustable
A10-8 1/4 1/2 1-3/4 3/4 23/32 compression fitting is desired, list
A10-9 5/16 1/8 1-23/64 3/8 3/4 the Part No. and BR.
A10-10 5/16 1/4 1-35/64 9/16 3/4 Example: A10-1-BR
A10-11 3/8 3/4 1-13/16 3/4 3/4
A10-12 3/8 1/4 1-19/32 9/16 25/32 • If a (SS - stainless steel) adjustable
A10-13 3/8 3/8 1-19/32 9/16 25/32 compression fitting is desired, add
A10-14 3/8 1/2 1-13/16 3/4 25/32 the suffix SS to the Part No.
A10-15 1/2 1/4 1-23/32 9/16 7/8 Example: A10-1-SS
A10-16 1/2 3/8 1-23/32 9/16 7/8
A10-17 1/2 1/2 1-29/32 3/4 7/8
A10-18 1/2 3/4 1-15/16 3/4 7/8
A10-19 5/8 3/8 1-3/4 9/16 7/8
A10-20 5/8 1/4 1-15/16 3/4 7/8
A10-22 3/4 3/4 2 3/4 7/8
A10-23 7/8 3/4 2 3/4 7/8
A10-25 1 1 2-7/16 15/16 1-1/32
Our line of High Temperature Thermocouples are specially designed for temperatures
ranging from 1,000 degrees Fahrenheit to 4,235 degrees Fahrenheit. Sheath materials
available from stock include tantalum, molybdenum, zirconia, alumina, and quartz. Chief
characteristics of the sheath materials are summarized.
TANTALUM (Ta):
Melting point of 5,430 degrees Fahrenheit; the most corrosive resistant of the refractory metals. Corrosion
resistant to most chemicals up to 3,000 degrees Fahrenheit. Good in reducing or neutral atmospheres
at elevated temperatures. Poor in oxidizing atmospheres and excellent for thermal cycling applications.
MOLYBDENUM (Mo):
Excellent mechanical properties at elevated temperatures. Melting point at 4,750 degrees Fahrenheit;
excellent in reducing or neutral atmospheres. Having low thermal-neutron capture cross-section and
excellent thermal shock resistance. Poor in oxidizing atmospheres but excellent for thermal cycling
applications.
ALUMINA (Al2O3):
This high purity sintered aluminum oxide (99.5% AI2O3, dense) has a melting point of 3,686 degrees
Fahrenheit (2,030 degrees Celsius) and an upper working service temperature of 3,482 degrees Fahrenheit
(1,900 degrees Celsius). It can be used in oxidizing, reducing, or high vacuum applications. Not
recommended for use in high vacuum environments in the presence of graphite at temperatures exceeding
2,372 degrees Fahrenheit (1,300 degrees Celsius). Alumina (AI2O3) has high thermal conductivity and
therefore fairly good resistance to thermal shock. Having excellent resistance to chemical attack but poor
for thermal cycling applications.
ZIRCONIA (ZRO2):
Zirconium oxide is fully stabilized with exceptional refractory properties, which include the highest
melting point and lowest thermal conductivity of any refractory. It is not wetted by most molten metals,
is generally inert to oxidizing and reducing atmospheres, and resists most chemical reactions. Usable to
4400°F. It is impervious (0% water absorption). Poor for thermal cycling applications.
FUSED QUARTZ:
Fused silica consists of 99,9%SiOi; most acids, metals, chlorine, and bromine are reactive with fused
silica at ordinary temperatures. Slightly attacked by alkaline solutions, the reaction rate increasing with
temperature and concentration of solution. Fused silica has an extremely low coefficient of thermal
expansion, 0.55 x 10-6 cm/cm/°F (0-572 degrees Fahrenheit). This is 1/34th that of copper, 1/17th of
platinum and 1/9th of tungsten. This low expansion produces a high thermal shock resistance, heated to
2700’’F, and immersed into ice water without cracking. Good for oxidizing, inert or neutral atmospheres
to 3,050 degrees Fahrenheit. Excellent for thermal shock applications; devitrifies rapidly at temperatures
above 1,800 degree Fahrenheit causing microscopic surface cracking (hazy film) upon cooling.
Applications:
Oxidizing, Vacuum, Reducing and Inert Gas Furnaces, Gas Burners, Ovens, Nuclear Power
Generating Plants, Exhaust Gases, Wind Tunnels, Pollution Control, and High Temperature
Process Control Applications.
This High Temperature Thermocouple Probe is also available with an optional, four inch
long support tube attached to the connector end. The purpose of the support tube is to
eliminate any damage to the refractory sheath that may be caused by the mounting bushing.
The support tube is 1/8 inch larger in diameter than the thermocouple sheath. If a support
tube is desired, insert the suffix (ST) onto the part number.
NOTES:
• These thermocouples all use a #30 gage • High temperature (800 degrees Fahrenheit)
(0.010”) size elements. connectors also available (contact factory
for your requirement).
• Various adjustable compression fittings and
mounting bushings are available. • When ordering, specify Part No.
thermocouple type and length.
• Duplex and multiple units are also available. Example: A11A-1-12-R
Specifications
Sheath Sheath
Part No.
Diameter Material
A11A-1 0.125
A11A-2 0.187 Molybdenum All A11A Series Probes
A11A-3 0.250
A11A-4 0.063
A11A-5 0.125 Ungrounded Junction
Tantalum
A11A-6 0.187
A11A-7 0.250
A11A-10 0.187
A11A-11 0.250 Alumina
A11A-12 0.375
A11A-14 0.250
Zirconia
A11A-15 0.375
A11A-16 0.187
A11A-17 0.250 Quartz
A11A-18 0.375
NOTES:
• These thermocouples use #30 gage (0.010”) size elements.
• Duplex and multiple units also available (contact factory)
• When ordering, specify Part No., Length “L” and thermocouple
type. Example: A11B-1-12-R
Specifications
Sheath Sheath
Part No.
Diameter Material
A11B-1 0.125
A11B-2 0.187 Molybdenum
A11B-3 0.250
A11B-5 0.125
A11B-6 0.187 Tantalum
A11B-7 0.250
A11B-9 0.187
A11B-10 0.250 Alumina
A11B-11 0.375
A11B-13 0.250
Zirconia
A11B-14 0.375
NOTES:
• These thermocouples use #30 gage • Various adjustable compression fittings and
(0.010”) size elements. mounting bushings are available.
• These units are available with a standard • Duplex and multiple units also available
miniature or high temperature connector (contact factory)
attached (contact factory).
• When ordering, specify Part No., Length “L”
• Various adjustable compression fittings and and thermocouple type.
mounting bushings are available. Example: A11B-1-12-R
Specifications
Part No. Sheath Diameter Sheath Material
A11C-1 0.125
A11C-2 0.187 Molybdenum
A11C-3 0.250
A11C-5 0.125
A11C-6 0.187 Tantalum
A11C-7 0.250
A11C-9 0.187
A11C-10 0.250 Alumina
A11C-11 0.375
A11C-13 0.250
Zirconia
A11C-14 0.375
This high temperature thermocouple probe is also available with a thick wall, four inch long
support tube attached to the connector end. The purpose of the support tube is to eliminate
any damage to the refractory sheath that may be caused by the mounting bushing. The
support tube is an 1/8 inch larger in diameter than the thermocouple sheath. If a support
tube is desired, insert the suffix (ST) onto the Part No.
NOTES:
• Duplex and multiple units also available
• These thermocouples use #24 gage (contact factory)
(0.020”) size elements.
• High temperature (800 degrees Fahrenheit)
• Various adjustable compression fittings and connectors and miniature plugs & jacks also
mounting bushings are available. available.
Specifications
Sheath Sheath
Part No.
Diameter Material
A12-1 0.125
A12-2 0.187 Molybdenum All A12 Series Probes
A12-3 0.250
A12-5 0.125
A12-6 0.187 Tantalum Ungrounded Junction
A12-7 0.250
A12-10 0.187
A12-11 0.250 Alumina
A12-12 0.375
A12-14 0.250
Zirconia
A12-15 0.375
A12-16 0.187
A12-17 0.250 Quartz
A12-18 0.375
NOTES:
• These thermocouples use #24 gage (0.020”) size elements.
• Duplex and multiple units also available (contact factory)
• When ordering, specify Part No. Length “L” and thermocouple
type.
Specifications
Sheath Sheath
Part No.
Diameter Material
A12A-1 0.125
A12A-2 0.187 Molybdenum
A12A-3 0.250
A12A-5 0.125
A12A-6 0.187 Tantalum
A12A-7 0.250
A12A-9 0.187
A12A-10 0.250 Alumina
A12A-11 0.375
A12A-13 0.250
Zirconia
A12A-14 0.375
This thermocouple is also available with a thick wall, four inch long support tube attached
to the transition end. The purpose of the support tube is to eliminate any damage to the
refractory sheath that may be caused by the mounting bushing. The support tube is an 1/8
inch larger in diameter than the thermocouple sheath. If a support tube is desired, insert the
suffix (ST) onto the Part No.
NOTES:
• These thermocouples use #24 gage
(0.020”) size elements. • Available with Standard, Miniature, or High
Temperature connectors attached (contact
• Various adjustable compression fittings and factory).
mounting bushings are available.
• When ordering, specify Part No. Length “L”
• Duplex and multiple units also available and thermocouple type.
(contact factory) Example: A12B-1-12-R
Specifications
Part No. Sheath Diameter Sheath Material
A12B-1 0.125
A12B-2 0.187 Molybdenum
A12B-3 0.250
A12B-5 0.125
A12B-6 0.187 Tantalum
A12B-7 0.250
A12B-9 0.187
A12B-10 0.250 Alumina
A12B-11 0.375
A12B-13 0.250
Zirconia
A12B-14 0.375
Many high pressure applications such as reaction chambers often times require temperature
monitoring and control at temperatures from 2,000 degrees Fahrenheit to over 3,000 degrees
Fahrenheit. Since refractory or ceramic sheathed thermocouples are used to monitor these
temperatures, the strength of these sheaths are not sufficient to withstand these external
pressures at these temperatures. In order to prevent the sheaths from collapsing, we have
drilled a small hole through the sheath at the sensing tip end, this feature allows the internal
pressure inside the sheath to equalize with the external pressure; thus, preventing the sheath
from collapsing. Also, we have built a gas-tight pressure seal into the thermowell; so that,
high pressure gases will not escape through the mineral oxide insulation.
Specifications
Part No. A12C-1 A12C-2 A12C-3 A12C-4 A12C-5 A12C-6 A12C-7 A12C-8 A12C-9 A12C-10
Sheath
0.125 0.187 0.250 0.125 0.187 0.250 0.250 0.375 0.250 0.375
Diameter “A” (in.)
NOTES: Specifications
• These thermocouples use #24 gage Part No. Type
D1 (in.) D2 (in.)
(0.020”) size elements and molybdenum Approximate
sheaths. A12D-1 0.150 0.250
A12D-2 C 0.220 0.250
• Various adjustable compression fittings and A12D-3 0.284 0.375
mounting bushings are available.
A12D-4 0.150 0.250
• Duplex and multiple units also available A12D-5 S 0.220 0.250
(contact factory) A12D-6 0.284 0.375
• When ordering, specify Part No. Length “L” A12D-7 0.150 0.250
and thermocouple type. A12D-8 R 0.220 0.250
Example: A12D-1-17-C A12D-9 0.284 0.375
Offering a wide variety of bare wire thermocouple elements in a large selection of wire sizes.
All base metal bare wire thermocouple types: E, J, K, N, and T come with a standard length
of 12 inch leads. Noble metal and refractory wire element types: B, D, C, S, and R come with
a standard element length of six inches. Other sizes and lengths are also available.
NOTES: • Elements with ceramic insulators are also
available (contact factory).
• All standard units have a twist and welded
junction, if requesting no twist use the suffix • All bare wire elements can be made to
NT. Example: A13-K-12-NT most lengths; contact the factory with your
requirement.
Specifications
12” Standard Lengths
Wire Dia.
Part No. Type
(in.)
A13-1 0.003
A13-2 0.005
A13-3 0.010
A13-4 0.015
A13-5 J 0.020
A13-6 0.032
A13-7 0.050
A13-8 0.064
Specifications A13-9 0.128
A13-10 0.003
6” Standard Lengths
A13-11 0.005
Wire Dia. A13-12 0.010
Part No. Type T
(in.) A13-13 0.015
A13-14 0.020
A13-31 0.005
A13-15 0.032
A13-32 0.010
S
A13-33 0.015 A13-16 0.003
A13-34 0.020 A13-17 0.005
A13-18 0.010
A13-35 0.005
A13-19 0.015
A13-36 0.010
R A13-20 K 0.020
A13-37 0.015
A13-21 0.032
A13-38 0.020
A13-22 0.050
A13-43 0.005 A13-23 0.064
A13-44 0.010 A13-24 0.128
D
A13-45 0.015
A13-25 0.003
A13-46 0.020
A13-26 0.005
A13-47 0.005 A13-27 0.010
E
A13-48 0.010 A13-28 0.015
C
A13-49 0.015 A13-29 0.020
A13-50 0.020 A13-30 0.032
A13-51 0.005 A13-60 0.020
A13-52 0.010 A13-61 0.032
B N
A13-53 0.015 A13-65 0.064
A13-54 0.020 A13-66 0.128
We stock a broad line of insulators for use with all types and sizes of thermocouple wire.
Mullite insulators are recommended for use with bare metal thermocouple wire and element
types: E, J, K, N, and T up to 2,700 degrees Fahrenheit. High purity alumina oxide is
recommended for use with noble or refractory thermocouple wire and element types: B, C,
D, R, and S. Re-crystallized alumina is suitable up to 3,600 degrees Fahrenheit.
NOTES: • Example: A14-1-6 (is an 1/8 inch OD Mullite,
2 bore, 0.040 bore size, six inches long)
• Specify length in six inch increments.
• Special lengths are available
Specifications
Illustrations
Nominal OD Nominal ID
Style Part No. Material
(in.) (in.)
A14-1 1/8 0.040
A14-2 3/16 0.060
A14-3 Mullite 1/4 0.080
Double Bore A14-4 3/8 0.110
Round A14-5 1/2 0.150
A14-6 1/8 0.040
Oxide 99
A14-7 3/16 0.060
(High Purity Alumina)
A14-8 1/4 0.080
Mullite ceramic insulators are recommended for use with base metal thermocouple wire
and elements types E, J, K, N & T. High purity Alumina oxide is recommended for use
with noble or refractory thermocouple wire and elements, types B, C, D, R & S. Alumina is
suitable for up to 3,600 degrees Fahrenheit. Mullite (60% AL2O3 / 39% SiO2) is suitable to
2,700 degrees Fahrenheit.
NOTES:
• Length do not include approximately one Style 2: Duplex Ceramic Insulated
inch of bare wire at the terminating end.
• These units are also available with short ball
and socket insulators for units required to
bend, curve, etc.
• Contact factory with your specific
requirements. Typically a sketch is required
to quote these unique designs. Style 3: Ball & Socket Ceramic Insulated
Thermocouples and extension leads with end preparations offer rapid solutions to many
temperature measurement applications at economical costs. All contain one pair of solid
conductors and are insulated with fiberglass over each leg and overall. Color codes and
premium grade elements are used throughout; thermocouple types include: E, J, K, N & T.
NOTES: A14B A B C D
• When ordering, specify Part No. and fill in Style Gauge Type Length
the four letter blocks. 1 8 J (inches)
• For stainless steel over braid add the suffix 2 14 K
SS to the Part No. 3 20 T
4 24 E
• Example: A14B-2-K-20-36 (specifies a style 2 N
thermocouple with spade lugs on cold end,
type K, gage #20 and an overall length of When ordering, specify Part No. and fill in the 4 letter blocks
Example: A14A-2-20-K-24 (specifies a Style 2 duplex thermocouple with 20
36 inches) gauge Type K elements and length of 24 inches.
Illustrations Specifications
Since all metal thermowells have a female NPT connection thread and
all connection heads also have a female NPT thread; a nipple with male
NPT threads on both ends is required to attach the connection head
to the thermowell. A secondary purpose of the nipple is to physically
remove the connection head from a hot thermowell to a safe distance
so that an operator can safely open the connection head and make
necessary replacements or repairs.
Material:
Thermowells consist of drilled bar stock.
Standard well materials include brass (ASTM B-16),
carbon steel (C-1018), and stainless steel (A.I.S.I
B-16). Wells are also available in special grades
of stainless steel, chrome-molybdenum alloys,
silicon bronze, Hastelloy B and C, nickle, titanium,
inconel, and monel. The particular choice is usually
determined by the corrosive conditions under which
the thermowell must operate-commensurate with
the maximum service pressure and temperature.
Specifications
Bore Diameter (B) = 0.260”
Exterior Stem Insertion Shank
Material Material Material Material
Thread Length Length Diameter
SS304 SS316 Carbon Steel Brass
(P) (A) (U) (Q)
Part No. Part No. Part No. Part No.
4 2-1/2 A21A-1 A21A-22 A21A-43 A21A-64
6 4-1/2 A21A-2 A21A-23 A21A-44 A21A-65
9 7-1/2 A21A-3 A21A-24 A21A-45 A21A-66
1/2” NPT 12 10-1/2 5/8” A21A-4 A21A-25 A21A-46 A21A-67
15 13-1/2 A21A-5 A21A-26 A21A-47 A21A-68
18 16-1/2 A21A-6 A21A-27 A21A-48 A21A-69
24 22-1/2 A21A-7 A21A-28 A21A-49 A21A-70
4 2-1/2 A21A-8 A21A-29 A21A-50 A21A-71
6 4-1/2 A21A-9 A21A-30 A21A-51 A21A-72
9 7-1/2 A21A-10 A21A-31 A21A-52 A21A-73
3/4” NPT 12 10-1/2 3/4” A21A-11 A21A-32 A21A-53 A21A-74
15 13-1/2 A21A-12 A21A-33 A21A-54 A21A-75
18 16-1/2 A21A-13 A21A-34 A21A-55 A21A-76
24 22-1/2 A21A-14 A21A-35 A21A-56 A21A-77
4 2-1/2 A21A-15 A21A-36 A21A-57 A21A-78
6 4-1/2 A21A-16 A21A-37 A21A-58 A21A-79
9 7-1/2 A21A-17 A21A-38 A21A-59 A21A-80
1” NPT 12 10-1/2 7/8” A21A-18 A21A-39 A21A-60 A21A-81
15 13-1/2 A21A-19 A21A-40 A21A-61 A21A-82
18 16-1/2 A21A-20 A21A-41 A21A-62 A21A-83
24 22-1/2 A21A-21 A21A-42 A21A-63 A21A-84
Specifications
Bore Diameter (B) = 0.260”
Lagging Exterior Stem Insertion Shank
Material Material Material Material
Extension Thread Length Length Diameter
SS 304 SS 316 Carbon Steel Brass
(T) (P) (A) (U) (Q)
Part No. Part No. Part No. Part No.
2 6 2-1/2 A22A-1 A22A-19 A22A-37 A22A-55
3 9 4-1/2 A22A-2 A22A-20 A22A-38 A22A-56
3 12 7-1/2 A22A-3 A22A-21 A22A-39 A22A-57
1/2” NPT 5/8”
3 15 10-1/2 A22A-4 A22A-22 A22A-40 A22A-58
3 18 13-1/2 A22A-5 A22A-23 A22A-41 A22A-59
3 24 19-1/2 A22A-6 A22A-24 A22A-42 A22A-60
2 6 2-1/2 A22A-7 A22A-25 A22A-43 A22A-61
3 9 4-1/2 A22A-8 A22A-26 A22A-44 A22A-62
3 12 7-1/2 A22A-9 A22A-27 A22A-45 A22A-63
3/4” NPT 3/4”
3 15 10-1/2 A22A-10 A22A-28 A22A-46 A22A-64
3 18 13-1/2 A22A-11 A22A-29 A22A-47 A22A-65
3 24 19-1/2 A22A-12 A22A-30 A22A-48 A22A-66
2 6 2-1/2 A22A-13 A22A-31 A22A-49 A22A-67
3 9 4-1/2 A22A-14 A22A-32 A22A-50 A22A-68
3 12 7-1/2 A22A-15 A22A-33 A22A-51 A22A-69
1” NPT 7/8”
3 15 10-1/2 A22A-16 A22A-34 A22A-52 A22A-70
3 18 13-1/2 A22A-17 A22A-35 A22A-53 A22A-71
3 24 19-1/2 A22A-18 A22A-36 A22A-54 A22A-72
Specifications
Bore Diameter (B) = 0.385”
Exterior Element Insertion
Material Material Material Material
Thread Length Length
SS304 SS316 Carbon Steel Brass
(P) (A) (U)
Part No. Part No. Part No. Part No.
4 2-1/2 A23-1 A23-15 A23-29 A23-43
6 4-1/2 A23-2 A23-16 A23-30 A23-44
9 7-1/2 A23-3 A23-17 A23-31 A23-45
3/4” NPT 12 10-1/2 A23-4 A23-18 A23-32 A23-46
15 13-1/2 A23-5 A23-19 A23-33 A23-47
18 16-1/2 A23-6 A23-20 A23-34 A23-48
24 22-1/2 A23-7 A23-21 A23-35 A23-49
4 2-1/2 A23-8 A23-22 A23-36 A23-50
6 4-1/2 A23-9 A23-23 A23-37 A23-51
9 7-1/2 A23-10 A23-24 A23-38 A23-52
1” NPT 12 10-1/2 A23-11 A23-25 A23-39 A23-53
15 13-1/2 A23-12 A23-26 A23-40 A23-54
18 16-1/2 A23-13 A23-27 A23-41 A23-55
24 22-1/2 A23-14 A23-28 A23-42 A23-56
Specifications
Bore Diameter (B) = 0.385”
Lagging Exterior Stem Insertion Shank
Material Material Material Material
Extension Thread Length Length Diameter
SS304 SS316 Carbon Steel Brass
(T) (P) (A) (U) (Q)
Part No. Part No. Part No. Part No.
2 6 2-1/2 A24A-1 A24A-13 A24A-25 A24A-37
3 9 4-1/2 A24A-2 A24A-14 A24A-26 A24A-38
3 12 7-1/2 A24A-3 A24A-15 A24A-27 A24A-39
3/4” NPT 3/4”
3 15 10-1/2 A24A-4 A24A-16 A24A-28 A24A-40
3 18 13-1/2 A24A-5 A24A-17 A24A-29 A24A-41
3 24 19-1/2 A24A-6 A24A-18 A24A-30 A24A-42
2 6 2-1/2 A24A-7 A24A-19 A24A-31 A24A-43
3 9 4-1/2 A24A-8 A24A-20 A24A-32 A24A-44
3 12 7-1/2 A24A-9 A24A-21 A24A-33 A24A-45
1” NPT 7/8”
3 15 10-1/2 A24A-10 A24A-22 A24A-34 A24A-46
3 18 13-1/2 A24A-11 A24A-23 A24A-35 A24A-47
3 24 19-1/2 A24A-12 A24A-24 A24A-36 A24A-48
NOTES:
• Stainless steel or brass compression fittings
are available for mounting probes into these
thermowells.
Specifications
Bore Diameter (B) = 0.260”
Shank Diameter Q1-7/8” Q2-5/8”
Exterior Stem Insertion
Thread Length Length Material Material Material Material
(P) (A) (U) SS304 SS316 Carbon Steel Brass
Part No. Part No. Part No. Part No.
4 2-1/2 A25-1 A25-15 A25-57 A25-43
6 4-1/2 A25-2 A25-16 A25-58 A25-44
9 7-1/2 A25-3 A25-17 A25-59 A25-45
3/4” NPT 12 10-1/2 A25-4 A25-18 A25-60 A25-46
15 13-1/2 A25-5 A25-19 A25-61 A25-47
18 19-1/2 A25-6 A25-20 A25-62 A25-48
24 22-1/2 A25-7 A25-21 A25-63 A25-49
4 2-1/2 A25-8 A25-22 A25-64 A25-50
6 4-1/2 A25-9 A25-23 A25-65 A25-51
9 7-1/2 A25-10 A25-24 A25-66 A25-52
1” NPT 12 10-1/2 A25-11 A25-25 A25-67 A25-53
15 13-1/2 A25-12 A25-26 A25-68 A25-54
18 19-1/2 A25-13 A25-27 A25-69 A25-55
24 22-1/2 A25-14 A25-28 A25-70 A25-56
Bore Diameter (B) 0.385”
Shank Diameter Q1-1-1/16” Q2-49/64”
4 2-1/2 A25-29 A25-36 A25-78 A25-71
6 4-1/2 A25-30 A25-37 A25-79 A25-72
9 7-1/2 A25-31 A25-38 A25-80 A25-73
1” NPT 12 10-1/2 A25-32 A25-39 A25-81 A25-74
15 13-1/2 A25-33 A25-40 A25-82 A25-75
18 19-1/2 A25-34 A25-41 A25-83 A25-76
24 22-1/2 A25-35 A25-42 A25-84 A25-77
NOTES:
• Stainless steel or brass compression
fittings are available for mounting
probes into these thermowells.
Specifications
Bore Diameter (B) = ~0.260”
Shank Diameter Q1-7/8” Q2-5/8”
Lagging Exterior Stem Insertion Shank
Extension Thread Length Length Diameter Material Material Material Material
(T) (P) (A) (U) (Q) SS304 SS316 Brass Carbon Steel
Part No. Part No. Part No. Part No.
2 6 2-1/2 A26A-1 A26A-13 A26A-37 A26A-49
3 9 4-1/2 A26A-2 A26A-14 A26A-38 A26A-50
3 12 7-1/2 A26A-3 A26A-15 A26A-39 A26A-51
3/4” NPT 3/4”
3 15 10-1/2 A26A-4 A26A-16 A26A-40 A26A-52
3 18 13-1/2 A26A-5 A26A-17 A26A-41 A26A-53
3 24 19-1/2 A26A-6 A26A-18 A26A-42 A26A-54
2 6 2-1/2 A26A-7 A26A-19 A26A-43 A26A-55
3 9 4-1/2 A26A-8 A26A-20 A26A-44 A26A-56
3 12 7-1/2 A26A-9 A26A-21 A26A-45 A26A-57
1” NPT 7/8”
3 15 10-1/2 A26A-10 A26A-22 A26A-46 A26A-58
3 18 13-1/2 A26A-11 A26A-23 A26A-47 A26A-59
3 24 19-1/2 A26A-12 A26A-24 A26A-48 A26A-60
Bore Diameter (B) = 0.385”
Shank Diameter Q1-1-1/16” Q2-49/64”
2 6 2-1/2 A26A-25 A26A-31 A26A-61 A26A-67
3 9 4-1/2 A26A-26 A26A-32 A26A-62 A26A-68
3 12 7-1/2 A26A-27 A26A-33 A26A-63 A26A-69
1” NPT 7/8”
3 15 10-1/2 A26A-28 A26A-34 A26A-64 A26A-70
3 18 13-1/2 A26A-29 A26A-35 A26A-65 A26A-71
3 24 19-1/2 A26A-30 A26A-36 A26A-66 A26A-72
NOTES:
• (RF - raised face) Standard ASA Serrated
• (FF - flat face), (RTF - ring type flange)
Thermowell must be
specified separately
Flange Specifications
Rating SS304 SS316 Carbon Steel Rating SS304 SS316 Carbon Steel
Size
Facing (lbs./in.2) Part No. Part No. Part No. (lbs./in.2) Part No. Part No. Part No.
(inch)
1 RF A27-1 A27-37 A27-73 A27-19 A27-55 A27-91
1-1/2 RF A27-2 A27-38 A27-74 A27-20 A27-56 A27-92
2 RF A27-3 A27-39 A27-75 A27-21 A27-57 A27-93
1 FF A27-4 A27-40 A27-76 A27-22 A27-58 A27-94
1-1/2 FF 150 A27-5 A27-41 A27-77 400 A27-23 A27-59 A27-95
2 FF A27-6 A27-42 A27-78 A27-24 A27-60 A27-96
1 RTJ A27-7 A27-43 A27-79 A27-25 A27-61 A27-97
1-1/2 RTJ A27-8 A27-44 A27-80 A27-26 A27-62 A27-98
2 RTJ A27-9 A27-45 A27-81 A27-27 A27-63 A27-99
1 RF A27-10 A27-46 A27-82 A27-28 A27-64 A27-100
1-1/2 RF A27-11 A27-47 A27-83 A27-29 A27-65 A27-101
2 RF A27-12 A27-48 A27-84 A27-30 A27-66 A27-102
1 FF A27-13 A27-49 A27-85 A27-31 A27-67 A27-103
1-1/2 FF 300 A27-14 A27-50 A27-86 900 A27-32 A27-68 A27-104
2 FF A27-15 A27-51 A27-87 A27-33 A27-69 A27-105
1 RTJ A27-16 A27-52 A27-88 A27-34 A27-70 A27-106
1-1/2 RTJ A27-17 A27-53 A27-89 A27-35 A27-71 A27-107
2 RTJ A27-18 A27-54 A27-90 A27-36 A27-72 A27-108
NOTES:
• Primary weld is a “J” groove type, secondary
• Thermowells available in SS 304, SS 316 weld is a 45 degree bevel groove. All
and C-1018. Monel and other materials may welding is performed by Navy certified
be available upon request. welders using inert gas shielded arc.
• NPSM internal pipe thread will accept NPT • Flanges for use with these thermowells must
and NPS male threads. be specified separately
Flanges to be specified
Thermowell Specifications
separately.
0.264” Bore for 1/4” 0.385” Bore for 3/8”
Diameter Elements - Q=3/4” Diameter Elements - Q=7/8”
SS304 SS316 Carbon Steel SS304 SS316 Carbon Steel
Element Insertion
Part No. Part No. Part No. Part No. Part No. Part No. Length A Length U
A28-1 A28-8 A28-15 A28-22 A28-29 A28-36 4 2
A28-2 A28-9 A28-16 A28-23 A28-30 A28-37 6 4
A28-3 A28-10 A28-17 A28-24 A28-31 A28-38 9 9
A28-4 A28-11 A28-18 A28-25 A28-32 A28-39 12 12
A28-5 A28-12 A28-19 A28-26 A28-33 A28-40 15 15
A28-6 A28-13 A28-20 A28-27 A28-34 A28-41 18 18
A28-7 A28-14 A28-21 A28-28 A28-35 A28-42 24 24
NOTES:
• The (brass cap - BRcap) and chain is
• On 1/2 inch NPT external threads, the available for keeping well bore clean when
“U” dimension becomes one inch to not in use. If cap and chain is desired add
accommodate the 1/2 inch NPSM female BRcap to the part number.
thread.
• If (stainless steel - SScap) and chain is
• Stainless steel or brass compression fittings desired, add SScap to the part number.
are available for mounting probes into these
thermowells. • Order by part number as indicated
Specifications
Exterior Maximum Fluid Velocity
Part No. Material
Thread (feet per second)
A29-1 SS 304 300
A29-2 SS 316 300
A29-3 Brass 1/2” NPT 207
A29-4 C-1020 290
A29-5 Monel 261
A29-6 SS 304 300
A29-7 SS 316 300
A29-8 Brass 3/4” NPT 207
A29-9 C-1020 290
A29-10 Monel 261
A29-11 SS 304 300
A29-12 SS 316 300
A29-13 Brass 1” NPT 207
A29-14 C-1020 290
A29-15 Monel 261
Specifications
NOTES: Style A Style B Style C Style D Style E
OD x ID Length Length
• For intermediate lengths, (in.) “L” Part Part “L” Part Part Part
specify Length “L”. No. No. No. No. No.
• Order by Part No. as 6 A30-1 A30-38
indicated 12 A30-2 A30-39
1/8 x 1/16 N/A N/A N/A N/A
18 A30-3 A30-40
24 A30-4 A30-41
6 A30-5 A30-42 5-1/4 A30-80
12 A30-6 A30-43 11-1/4 A30-81
Specify Part No. and length 1/4 x 5/32
18 A30-7 A30-44 17-1/4
N/A
A30-82
N/A
Example: A30-42-36 24 A30-8 A30-45 23-1/4 A30-83
6 A30-9 A30-46 5-1/4 A30-84 A30-93
12 A30-10 A30-47 11-1/4 A30-85 A30-94
3/8 x 1/4 N/A
18 A30-11 A30-48 17-1/4 A30-86 A30-95
24 A30-12 A30-49 23-1/4 A30-87 A30-96
We offer high purity Zirconia and Alumina ceramic protection tubes along with Molybdenum
A
and Tantalum metal tubing for high temperature applications. In addition to the size
specifications, additional performance information is available; as well as, other diameters
and types of protection tubes (contact the factory with your specific requirement).
Special Note: Various lengths and diameter sizes are available.
Specifications
Ceramic
OD x ID Length
Part No. Material
(in.) (in.)
A31-1 6
A31-2 12
Alumina 1/8 x 1/16
A31-3 18
A31-4 24
A31-5 6
A31-6 12
Alumina 5/32 x 5/64
A31-7 18
A31-8 24
A31-9 6 Refractory Metal
A31-10 12
Alumina 1/4 x 3/16
A31-11 18
A31-12 24
A31-40 6
A31-41 12
A31-42 18
Alumina 3/8 x 1/4
A31-43 24
A31-44 30
A31-45 36
A31-50 6
A31-51 12
A31-52 18
Alumina 1/2 x 3/8
A31-53 24
A31-54 30
NOTES:
A31-55 36 • For ceramic protection tubes order by Part No.
A31-61 12 (Example: A31-1, specifies a six inch long 1/8
A31-62 Zirconia 1/4 x 3/16 18 OD x 1/16 ID alumina tube).
A31-63 24
• All ceramic tubes come closed end, for ceramic
A31-70 6 tubes open both ends, specify as follows
A31-71
Zirconia 3/8 x 1/4
12 Example: A31-12-9-OBE
A31-72 18
A31-73 24 • Tubes are typically made in six inch increments.
You must specify a base Part No. longer than
Refractory Metal Tubing
your required cut lengths when ordering (OBE
Open Both Ends
- open both ends). Example: 12 inch tube open
Part No. Material
OD x ID Length both ends requires an 18 inch tube to be cut
(in.) (in.) down.
A31-80 0.125 x 0.015 108 • For refractory tubing with one end welded
A31-81 Tantalum 0.187 x 0.020 108 closed and leak tested to 80 PSI contact factory.
A31-82 0.250 x 0.030 108
A31-90 0.125 x 0.015 98
• For refractory tubing, list Part No. and length
A31-91 0.187 x 0.020 98
of the tube (Example: A31-92-24, specifies
A31-92
Molybdenum
0.250 x 0.030 98 molybdenum tubing, 1/4 inch OD with 0.030
A31-93 0.250 x 0.050 98 thick wall, 24 inches long, open both ends).
Specifications
ID x OD Max. Length
Part No. Material NPT Style
(in.) (in.)
A32-1 Inco 601 0.622 x 0.840 1/2” 60
A32-2 Inco 601 0.824 x 1.050 3/4” 60 N/A
A32-3 Inco 601 1.049x 1.315 1” 60
A32-4 SS 304 0.622 x 0.840 1/2” 60
A32-5 SS 304 0.824 x 1.050 3/4” 60 N/A
A32-6 SS 304 1.049x 1.315 1” 60
A32-7 SS 446 0.622 x 0.840 1/2” 60
A32-8 SS 446 0.824 x 1.050 3/4” 60 N/A
A32-9 SS 446 1.049x 1.315 1” 60
A32-10 Silicon Carbide 1 x 1-3/4 - 48 Plain Pipe
A32-11 Silicon Carbide 1 x 1-3/4 - 48 with Collar
Silicon Carbide
A32-30 0.59 x 2.0 1/2” 48 N/A
Molded to Steel
Silicon Carbide
A32-31 0.79 x 2.0 3/4” 48 N/A
Molded to Steel
Our standard assembly consists of the metal alloy protection tube with a general purpose
aluminum connector head attached. The connector head has a 1/2 NPT outlet port. This
unit is assembled with a Chromel Alumel (Type K) ungrounded thermocouple with ceramic
insulators and is connected to a two-wire ceramic terminal block in the connector head.
Type J, K, or N available
Specifications
Max. Sheath
Exposed Junction
Sheath
Part No. Sheath OD x ID
Material
Length (in.)
A33-10 0.540 x 0.364
A33-11 0.840 x 0.622
Inconel 601 60”
A33-12 1.050 x 0.824
A33-13 1.315 x 1.049
A33-14 0.540 x 0.364
A33-15
SS 304 60”
0.840 x 0.622 Grounded Junction
A33-16 1.050 x 0.824
A33-17 1.315 x 1.049
A33-18 0.540 x 0.364
A33-19 0.840 x 0.622
SS 446 60”
A33-20 1.050 x 0.824
A33-21 1.315 x 1.049
A33-22 0.540 x 0.364
A33-23 0.840 x 0.622
A33-24
Carbon Steel 60”
1.050 x 0.824 Ungrounded Junction
A33-25 1.315 x 1.049
A33-26 0.540 x 0.364
A33-27 0.840 x 0.622
Hastelloy C 60”
A33-28 1.050 x 0.824
A33-29 1.315 x 1.049
In addition to straight assembly units, we offer a right angle type cold leg extension. We
use a general purpose (GP) connector head to make the bend instead of using a pipe elbow.
This GP connector allows easier maintenance, servicing and replacement of components;
thus reducing your overall costs.
The cold leg consists of a carbon steel pipe of a specified length with 1/2” NPT threaded
ends. The carbon steel extension terminates in a GP connection head with a 2 wire terminal
block inside, the exit port is 1/2” NPT. Maximum service temperature of the cold leg and the
GP connector is 1,000 degrees Fahrenheit.
When ordering this cold leg extension assembly, start with the
Part No. of the thermocouple or RTD assembly you require.
NOTES:
• Add the suffix CL (cold leg) and
the length of the CL to the
Part No.
• Example: A33-1-18-CL-24,
specifies an A33-1 Thermocouple
with an 18 inch sheath, and
cold leg (CL) extension with
a length of 24” (for special
design requirements contact the
factory).
Specifications
Cold Leg Length
18”
24”
30”
36”
Our thermocouple assemblies with various ceramic protection tubes are designed for high
temperature applications. All units use a stainless steel support tube which protects the
ceramic sheath from breakage while using an adjustable mounting adaptor. All units are
closed end and are gas tight, these units can be used in vacuum furnaces. A secondary
wire seal is made at the terminating end to assure a vacuum tight seal even if the ceramic
hot section is damaged. All units have an ungrounded thermal junction.
NOTES: • When ordering specify Part No. probe
length and thermocouple type.
• All units come with an aluminum connector
head. • Example: A35-10-18-K, specifies type K with
alumina sheath which is 18 inches long and
• For a steel support tube longer than four 0.375 OD.
inches contact factory.
• All units come with a stainless steel support
• Adjustable compression fittings are available tube which is four inches long and 1/8 inch
for use with these probes. larger in diameter than the sheath diameter.
Specifications
Sheath Maximum Support Tube
Sheath
Part No. Diameter Length Diamter Type
Material
(in.) (in.) (in.)
A35-10 Alumina 0.375 36 0.500
A35-11 Alumina 0.500 36 0.625
A35-12 Alumina 0.750 36 1.000
A35-13 Mullite 0.375 24 0.500
E, J, K, T
A35-14 Mullite 0.500 36 0.625
A35-16 Zirconia 0.250 18 0.375
A35-17 Zirconia 0.375 24 0.500
A35-18 Quartz 0.250 36 0.375
Our thermocouple assemblies with NC-11 protection sheaths are designed for high
temperature use. Our metal-ceramic protection tube NC-11 is a hard, abrasion-resistant,
dense material made from two high temperature compatible materials. The combination
of this high temperature metal and oxide produces a product with three very important
properties. The properties are: superior oxidation resistance to 2,500 degrees Fahrenheit,
thermal conductivity comparable to that of stainless steel, and good resistance to wetting by
most molten metals.
Applications Include:
• Molten copper and brass to 2,100 degrees • Molten zinc to 1,600 degrees Fahrenheit
Fahrenheit intermittent and continuous
immersions. • Molten lead to 650 degrees Fahrenheit
• Corrosive SO and SO gas (to 2,500 degrees • Basic steel and stags to 3,150 degrees
Fahrenheit) and SO and HP gas (to 2,000 Fahrenheit (intermittent) and 2,500 degrees
degrees Fahrenheit). Fahrenheit (continuous in open hearth and
general foundry practices).
• Open hearth furnace checker chambers to
2,450 degrees Fahrenheit. • Fluid bed cement process with severe
corrosion and temperature to 2,400 degrees
• Pelletizing chamber of Taconite refining Fahrenheit (fluid method of producing
operation to 2,100 degrees Fahrenheit. builders cement).
Specifications
Length
Part No. Type of Mounting
(in.)
A37-1-12-(specify: J, K , N) 12
A37-1-18-(specify: J, K , N) 18 Five inch long, one inch NPT,
A37-1-24-(specify: J, K , N) 24 stainless steel support tube.
A37-1-48-(specify: J, K , N) 48
The NC-12 protection tube is a dense, sintered ceramic especially designed for use
in many molten non-ferrous metals and corrosive chemicals. It is very strong, thermally
shock resistant and dimensionally stable. Additionally NC-12 is vacuum-tight and has high
electrical resistance. Mechanical strength is retained at extremely high temperatures (over
1,000 degrees Celsius in air). These features together with very low wear resistance, makes
NC-12 an ideal thermocouple protection tube for applications such as molten aluminum,
lead, tin, and zinc. Preheating is not necessary because NC-12 has a very low thermal
expansion coefficient.
Our NC-12 Protection tubes are also recommended for use in oxidizing environments
to 2,200 degrees Fahrenheit. Most acids, such as hydrochloric, nitric, sulphuric, and
phosphoric, do not attack NC-12. This material is also resistant to hydrogen gas. It is not
recommended for use with caustic solutions and hydrofluoric acid.
NOTES: • This support tube is of universal design. It
comes in either one inch of 1-1/4 inch NPT
• Standard units come with thermocouple pipe threads (depending on diameter of
type K installed. protection tube).
• For duplex units or other calibrations • Complete with wrench flats for easy
contact factory. installation and it can accept flanges.
• Standard support tube is five inches long of • Longer length support tubes are available
stainless steel. (contact factory).
NOTES:
• When ordering intrinsic thermocouples
• When ordering specify part number, simply add the suffix IT to the part number
thermocouple calibration type, and length of desired configuration of the flexible
in inches (standard length is 12 inches). Ribbon Thermocouple.
Example: B2-3-J-20 Example: B2-4-K-24-IT
Figure 1
Figure 2
Figure 3
(Intrinsic design, no premade thermal junction)
Specifications
Wire Diameter Ribbon Thickness Stainless Steel
Part No. Insulation
(in.) (approximate) Sheath (dia.)
B2-1 0.005 0.001” fiberglass -
B2-2 0.010 0.0015” fiberglass -
B2-3 0.020 0.0025” fiberglass -
B2-4 0.006 0.001” ceramic 0.040”
B2-5 0.013 0.0015” ceramic 0.062”
B2-6 0.020 0.0025” ceramic 0.125”
The Model RCF thermocouple has a flat ribbon sensing tip (1/2 inch wide by 7/9 inches B
long by ~0.002 inches thick) with 36 inches of flexible fiberglass leads. This model has low
millisecond response times.
The Model RCS thermocouple is similar to Model RCF except, it has a 12 inch long
stainless steel clad, ceramic packed extension shaft. As a result, the sensor can operate
up to temperatures of 2,000 degrees Fahrenheit maximum, depending upon thermocouple
type and duration of exposure.
The Model WT weldable tab thermocouple has a 3/4 inch by 3/4 inch by 0.030 inch thick
stainless steel welding tab, brazed onto a grounded junction (1/8 inch OD thermocouple). It
also has 36 inches of fiberglass insulated extension leads. The sensing tip has a maximum
service temperature of 1,000 degrees Fahrenheit.
Model RCF
Model RCS
Model WT
Specifications
“A” “B” “C”
Part No. Model Wire Size (in.)
Dimension (in.) Dimension (in.) Dimension (in.)
B4-1 0.020 7/8 1/2 -
RCF
B4-2 0.013 5/8 3/8 -
B4-3 0.020 7/8 1/2 1/8
RCS
B4-4 0.013 5/8 3/8 1/16
B4-5 0.020 - - 1/8
WT
B4-6 0.013 - - 1/16
FFM Model
Specifications
NOTES: Part No. Model
• Specify part number and thermocouple B6-1 RDD with Mounting Block
type when ordering. B6-2 FFM with Mounting Block
Example: B6-1-K B6-4 RDD only
B6-5 FFM only
B6-6 Mounting Block only
Our Ribbon Thermocouples for surface temperature measurement contains a 0.002 inch
thick loop-ribbon junction inside a spring-loaded protective shield. When applied against any
surface, the protective shield retracts enough to allow the ribbon junction to make intimate
contact with the wall. Because the ribbon junction eliminates conduction errors caused
by the stem of the thermocouple, surface temperature of any wall or object is measured
accurately. Response time of this new design is in the low milliseconds. Temperature range
is from cryogenic to 600 degrees Fahrenheit (higher temperature ranges on special request).
NOTES:
• Low mass sensing elements • Available in thermocouple calibration type K
• Large contact area improving accuracy and • When ordering specify by part number
eliminates conduction errors.
• All standard units are straight probes. If a
• Spring loaded protective shield protects 90 degree bend is desired, add (-90) to the
probe from physical damage and produces part number.
the same contact pressure in each Example: B7-1-90
application. It also contacts the object at
only five points; thus, minimizing any local • Special units with other dimensions are
thermal disturbances. available upon request.
Applications
• Hot Plates • Plastics Processing
• Surfaces • Machinery
• Walls • Ducts
• Ovens • Steam Lines
• Bearings • Air
• Engine Blocks • Gases, etc.
Specifications
Part No. Termination Style Type
Transition splice with spring relief plus 12 inches of coiled
B7-2 K
retractable cable with miniature male connector attached.
Plastic handle with spring relief plus 12 inches of coiled
B7-3 K
retractable cable with miniature male connector attached.
The Trident Thermocouple probe has an exposed ribbon style element. The ribbon element
is 0.002 inches thick, by 0.060 inches wide. Featuring spring-like stainless steel side guards
to protect the element from accidental damage. This sensor has no measurable conduction
error and is ideal for all types of surface contact measurements. Examples include: cloth,
textiles, thin plastics, rotating drums, hot plates, and/or any surface whose temperature is
desired. This sensor can even measure the temperature difference between black and white
on a sheet of paper when heated by a 60 watt light bulb from a distance of two feet.
Response time of this Trident probe is in the low milliseconds and usually limited only by
the meter taking the temperature readings. Standard termination style is a four inch plastic
handle, PVC insulated coil cord and mini thermocouple connector.
Trident Style
Specifications
NOTES:
Part No. Style Termination Type
• For special style surface probes or other B8-9 J
dimensions, terminations, or calibrations B8-10
Trident Style Plastic Handle
K
contact the factory. B8-11
Ribbon Coil Cord and
E
Thermocouple Mini-Connector
B8-12 T
All units come with a Delrin locking element (slug), which when used resists loosening due
to vibration. However, this limits the upper temperature limit to 300 degrees Fahrenheit. The
Delrin slug can easily be removed with a pair of pliers, increasing the upper temperature limit
to 450 degrees Fahrenheit. If higher temperatures are required please provide us with your
particular requirement.
NOTES:
• Low millisecond response times in
contact applications.
• Temperature rating to 450 degrees
Fahrenheit.
• Self-locking Delrin plug
• Choice of thermocouple types E, J,
K, N & T
• All units come with 48 inches of
teflon insulated lead wire.
Specifications
Thread Thread Rod Rod Dia. Force (lbs.)
Part No.
Size (in.) Length (in.) Length (in.) (in.) Initial - Final
B9-1(*) 1/4-28 1 3/16 0.090 1.0 - 4.0
B9-2(*) 3/8-16 1-1/8 3/16 0.187 2.8 - 7.2
B9-3(*) 1/2-13 1-1/4 1/4 0.248 2.7 - 9.3
B9-4(*) 5/8-11 1-1/2 5/16 0.310 10.5 - 25.5
The ribbon elements, due to their mass to surface-area relationship; provide fast response
times to equilibrium temperatures since the maximum surface contact area is offered to the
heat source.
• Probe materials may be metal, plastic, or
NOTES: ceramic
• Response times of 18 milliseconds in boiling • Mountings may be adjustable compression
water tests fittings on fixed mountings
• Pressure ranges to 10,000 psi, temperature • All standard thermocouple calibrations and
ranges to 3,200 degrees Fahrenheit connectors available.
The adjustable probe unit includes an adjustable compression fitting with standard pipe
threads. The probe may be from 3/16 inch OD and up, though standard sizes are 1/4 and
3/8 inch. Lengths can be from one inch to as much as 24 inches long, with a standard length
of four inches. Probe may be made from most any metal, plastic, or phenolic compound.
This style is ideally suited for gas and liquid surface and immersion applications.
C
The Surface mounted unit contains the right angle thermocouple on the end of the
threaded thermowell. The thermowell is stainless steel with straight threads (7/16 NF-2 by
13/32 inches long). It also contains an O-ring seal (good to 450 degrees Fahrenheit). At
higher temperatures, the O-ring must be removed and replaced by a copper washer. This
fluid mounted unit is ideal for applications requiring gas or liquid temperatures at the inner
surface of a container wall.
The fixed probe unit contains a 1/4 inch OD stainless steel probe on the end of a straight
thread mounting bushing (size of threads 1/2-20 NF x 3/4 inches long). The fixed probe unit
is ideal for measuring gas or liquid temperatures inside a container under high pressures.
Specifications
Diameter Length Maximum
Probe Mounting
Part No. “A” “L” Pressure
Material Type
(in.) (in.) (psi)
C2-1 SS 304 1/4 OD 4 1/8 NPT 3,000
C2-2 SS 304 3/8 OD 4 1/4 NPT 3,000
C2-3 Inconel 1/4 OD 4 1/8 NPT 3,000
C2-4 Copper 1/4 OD 4 1/8 NPT 3,000
C2-5 SS 316 - - 7/16-20 NF by 13/32 5,000
C2-7 SS 304 1/4 OD 4 1/2-20 NF by 3/4 10,000
Rigid Design
Flexible Design
This Right-Angle Ribbon sensor features a thermal junction of thin ribbons welded together
at the sensing tip. These ribbons are brought out from opposing sides of the probe between
the interface of an insulting rod and cone assembly. The ribbons in the vicinity of the media
being measured are parallel to the plane of the heat source. Thus, both the ribbons and
the thermal junction are heated simultaneously and conduction errors are eliminated. The
ribbon elements also allow for fast response times to temperature change. Since there
is a large surface area to cross-section area ratio in the ribbon design as compared to
round wires.
NOTES:
• Standard probe comes with a two-prong
standard plug connector attached. Mating jack
connector with cable clamp is furnished with
each unit.
• Thermocouple junction has no conduction
errors
• Pressure range to 4,000 psi
• Low millisecond response time to temperature
changes
• Temperature range from -320 to 2,000 degrees
Fahrenheit
• Available in thermocouple calibration types E,
J, K, N, and T
• When ordering specify part number C5
and thermocouple calibration type.
Example: C5-J
This series of Right Angle Ribbon Thermocouple features a stainless steel diaphragm
over the ribbon thermal junction. This diaphragm is 0.015 inches thick. The design is used
whenever a 100% sanitary requirement is required. Applications such as manufacturing
foods or medicines occasionally require this feature.
This Right Angle Ribbon Thermocouple sensor features a thermal junction of thin ribbons
welded together at the sensing tip. These ribbons are brought out from opposing sides
of the probe between the interface of an insulating rod and cone assembly. The ribbons
in the vicinity of the media being measured are parallel to the plane of the heat source.
Thus, both the ribbons and the thermal junction are heated simultaneously and conduction
errors are eliminated. The ribbon elements also allow for fast response times to temperature
change. Since there is a large surface area to cross-section area ratio in the ribbon design
as compared to round wires.
This assembled ribbon junction is then installed into a special thermowell which has a
0.015 inch thick diaphragm on its tip. Thus, the thermal junction is now in intimate thermal
contact with the stainless steel diaphragm. This produces an electrically grounded thermal
junction. When an ungrounded junction is desired, a thin disc of electrical insulating material
is inserted between the junction and the diaphragm. Special attention is made to use a
material with good heat transfer properties.
NOTES:
• Standard probe comes with a two-prong standard plug
connector attached.
• Mating jack connector with cable clamp is furnished with
each unit.
• Contact us for special units and other calibrations
• Fast response times
Specifications
• Minimum conduction errors
Part No. Type
• Available in types E, J, K, N & T
C6-J J
• Pressure range to 500 psi C6-K K
C6-E E
• Temperature range from C6-T T
-320 to 2,000°F
The C8-SE model Extrude-O-Couple is designed to fit into standard holes existing in
most nozzles for thermocouple or pressure gauge applications. This thermocouple has a
two-piece stainless steel thermowell which allows for better sealing at the conical surface,
automatically self aligning even in slightly offset machined holes. All connector types are
available, as are thermocouple types E, J, K, N & T.
The C8-LE model Extrude-O-Couple is designed for use on thick-walled extruder nozzles
requiring long thermocouples to fit into deep holes. Also it is designed to fit into holes in most
nozzles which are modified to receive thermocouples or pressure gauges. The Nanmac
C8-LE is a three-piece assembly thermocouple,
Model ME
rotating gland nut and a spacer. The length of
the spacer must be specified to accommodate
your requirements. The C8-LE model is available
in thermocouple types E, J, K, N &T. When
ordering specify model number, calibration, and
dimension “L” to the nearest 1/8 inch.
Model SE
Specifications
Part No. Model Type
C8-1 E
C8-2 J
ME
C8-3 T
C8-4 K
Model LE
C8-5 E
C8-6 J
SE
C8-7 T
C8-8 K
C8-9 E
C8-10 J
LE
C8-11 T
C8-12 K
The Fixed Immersion Tip unit includes a gland nut and a thermowell. The sensing tip
of the thermowell has a wedge shaped tip to minimize the shear effects. Therefore, the
leading edge of the wedge must face up-stream (into the oncoming plastic). A peen mark
is machined onto the thermocouple near the connector to indicate orientation for this
unidirectional installation. Also, wrench flats are provided to hold the thermocouple in place
while tightening the gland nut. Maximum service temperature and pressure rating of this unit
is 750 degrees Fahrenheit and 20,000 psi respectively.
The Adjustable Immersion Tip unit in similar to the fixed unit; except, the immersion length
is adjustable to any depth from flush on inner wall (to one inch immersion). Also, the sensing
tip is omnidirectional instead of unidirectional and spherically shaped to minimize shear
effects. On the connector end of this unit there are circular grooves machined into the shaft
at 1/10 inch intervals. These grooves are for indicating the insertion depth of the sensing tip
while the unit is installed. After installation and before plastic hardens/freezes you simply
screw the thermowell in or out to the desired insertion depth. An internal O-ring provides a
leak tight seal to 10,000 psi at melt temperatures of up to 600 degrees Fahrenheit. Adjustment
needs to be done either while
plastic is in its liquid state or upon
initial installation when there is no
plastic present.
Specifications
Dimension
Part No. Description
“A” (inches)
C8A-1 Fixed 1/2
C8A-2 Fixed 3/4
C8A-3 Fixed 1
* C8A-4 Adjustable 1/4 - 1-1/4
The MCR Model has an exposed flush-mounted ribbon Cutaway view of typical installation
thermocouple on its conical sensing tip. The one-piece
stainless steel thermocouple well is designed for internal
type installation secured with lock washers and jam nut.
Each unit is furnished with jam nuts, lock washers and
three feet of fiberglass insulated lead wire. Suitable for use
to 2,000 psi at temperatures to 400 degrees Fahrenheit.
MCR Model
The MDA Model has an exposed flush-mounted
ribbon thermocouple on its sensing surface. The one-
C
piece stainless steel thermocouple well is designed for
external type installation using the stainless steel gland
nut and three feet of fiberglass insulated extension leads.
Suitable for use to 2,000 psi at temperatures to 400 MDA Model
degree Fahrenheit.
Stainless steel 316 receptacle (MCR series) designed to be welded into mixer wall. Available
with dimension “L” from 1-1/4 to 4-1/2 inches increments of 1/4 inch. The MCR series mixer
thermocouple requires one teflon conical seal (Part No. C11-70).
Specifications
MDA Receptacle MCR Receptacle
Dimension
Part No. Description
“L”
C11-2 1-1/2
C11-6 2-1/2 MDA Receptacle,
C11-12 4 SS 316
C11-13 4-1/4
MDA Spacer,
C11-20 1/4 SS 303
C11-30 2-3/4 Required for MDA receptacle.
MDA Spacer Conical Seal Conical Seal C11-31 3 Spacer is 1-1/4” shorter than
receptacle.
(MDA) (MCR) C11-40 1-1/4
C11-43 2
MCR Receptacle,
C11-47 3
SS 316
C11-51 4
C11-53 4-1/2
C11-60 MDA Teflon
C11-70 MCR Conical Seal
NOTES:
Applications:
• Thermocouple junction has minimal conduction
errors • Chemical Processing
• Junction can be located flush with inner wall • Heat Exchangers D
surface or protruded into the flowing media • Oil, Fuel, Gas, Water / Steam
• 20 milliseconds response time to temperature • Hydraulic or Pneumatic Systems
changes
• Foams and Pastes
• Pressure range to 4,000 psi
• Cryogenic Materials
• Temperature range from -320 to 1,250 degrees
Fahrenheit • Heat Transfer and Superheaters
• All stainless steel fittings with other materials • Plastics
available
• Any tube or pipeline where accurate
• Sizes from 1/4 to two inches are available temperature measurement is required
Specifications
Tube Size Thread Size Hex Approximate Length Maximum
Part No.
(D) (T) (H) (L) Pressure
D3-4 1/4 7/16 - 20 7/8 1.7 4,000
D3-6 3/8 9/16 - 18 7/8 1.8 4,000
D3-8 1/2 3/4 - 16 7/8 2.0 3,000
D3-10 5/8 7/8 - 14 13/16 2.2 3,000
D3-12 3/4 1-1/16 - 12 1-1/8 2.6 3,000
D3-16 1 1-5/16 - 12 1-3/8 2.7 2,000
Specifications
Part No. T (diameter) A (in.)
D4-80 1/4 2.14
D4-81 5/16 2.34
D4-82 3/8 2.40
D4-83 1/2 2.76
D4-84 5/8 2.92
D4-85 3/4 3.02
D4-86 1 3.58
NOTES:
• Temperature Range: -320 to 1,250 degrees • Termination: 3/8 inch OD stainless steel tube
Fahrenheit with standard size 2 pin male plug attached.
• Pressures up to 4,000psi • Termination Styles: Transition to Flex Leads,
Explosion Proof Connector Head, 3 or 4
• Response Times: Thermocouples (20ms) wire RTD, Flexible Lead Wire, etc. (contact
and RTDs (3s) factory)
• Available Types: Thermocouples (J, K, E & • Union Type: 316 stainless steel compression
T) and RTDs (Pt100 2 wire standard) tube union
Male Female
RTDs come
standard with
diaphragm.
Thermocouples
with a diaphragm
are available upon
request.
Specifications
Male Female Maximum (psi)
Part No. Pipe Size
Dm Hm Am Df Hf Af Male Female
D4A-4 1/8 3/16 7/16 1-7/32 11/32 9/16 13/16 4,000 4,000
D4A-6 1/4 9/32 9/16 1-19/32 7/16 3/4 1-1/8 4,000 4,000
D4A-8 3/8 3/8 11/16 1-5/8 37/64 7/8 1-1/4 4,000 3,500
D4A-10 1/2 15/32 7/8 2 23/32 1-1/16 1-1/2 4,000 3,500
D4A-12 3/4 5/8 1-1/16 2 59/64 1-1/4 1-9/16 4,000 3,500
D4A-16 1 7/8 1-3/8 2-1/4 1-1/64 1-5/8 2 4,000 3,000
D4A-20 1-1/4 1-3/32 1-3/4 1-13/32 1-1/2 2-1/8 2-3/8 3,000 2,000
D4A-24 1-1/2 1-11/32 2-1/8 1-21/32 1-3/4 2-3/8 2-5/8 2,500 1,000
D4A-32 2 1-13/16 2-3/4 1-29/32 2-7/8 2-7/8 2-5/8 2,500 1,000
NOTES:
• Conventional thermocouple with stainless
steel sheaths and grounded junctions
• Available in thermocouple calibration
types: E, J, K, N & T
• Also available with Pt100 ohm RTD
• Temperature range to 500 degrees
Fahrenheit
• Pressure range to 500 psi
• Sensing junction immersed 1/3 diameter
into stream
Specifications
Part No. Tube OD (D) Hex (H) Length (L)
D7-4T-(•)-(*) 1/4 9/16 2.12
D7-5T-(•)-(*) 5/16 5/8 2.34
D7-6T-(•)-(*) 3/8 11/16 2.40
D7-8T-(•)-(*) 1/2 7/8 2.84
D7-10T-(•)-(*) 5/8 1.0 3.06
D7-12T-(•)-(*) 3/4 1-1/8 3.14
D7-16T-(•)-(*) 1.0 1-1/2 3.86
These thermocouples are made with stainless steel housings. The useful range of the
thermocouple element inside may exceed the melting point of stainless steel (2,550 degrees
Fahrenheit). Therefore, we suggest you contact one of our engineers with the unique details
and use for temperatures expected to be above this range.
Modification & customization is almost limitless on this device - Contact Factory
Specifications
Maximum Pressure
Part No. Thread Size
(psi)
E6-10 5,000 10 NF x 1/2”
E6-20 25,000 3/8 - 24 NF x 1/2”
E6-30 25,000 1/2 - 20 NF x 3/4”
E6-40 25,000 1/2 - 20 NF x 3/4”
In-Wall Temperature
Used as an in-wall temperature measuring probe, the Nanmac Self-Renewing Thermocouple
can be positioned to an accuracy of better than ±0.001 inches. This feature, together with
the fast response times of this probe make it an ideal in-wall thermocouple.
Immersion Temperature
Under certain applications the Nanmac Self-Renewing Thermocouple can be used for
immersion applications such as within the stream of flowing plastic or high velocity gases. It
is however recommended that Nanmac engineers should be consulted for the thermocouple
design best suited for immersion.
NOTES:
• 20 milliseconds response time to transient
temperatures
• Thermocouple junction renewable by filing or
sanding the probe tip.
• Two-dimensional thermal junction for accurate
positioning of the sensing tip.
• Temperature range up to 4,000 degrees
Fahrenheit
• Pressure range up to 10,000 psi
• Probe diameters 1/8” OD and up
• Probe housing material fabricated from any
machinable material.
• Sensing tip can be machined to match any
desired shape.
NOTES:
• Includes a stainless steel adjustable
compression fitting with 1/8 NPT threads
(3/8 inch OD probes use a 1/4 inch NPT • All Tantalum units are thermally ungrounded
fitting). and require construction that utilizes a
union to join the thermocouple probe to the
• Other size NPT or O-Ring fittings are stainless steel sheathed leads (stem).
available.
• A standard thermocouple plug is attached
to all units (female connectors are supplied).
Specifications
Material and Dimensions (in.)
Part No.
A B C D
* Tantalum requires slight
E12-1 SS 304 0.250 4 0.125
design modifications - contact E12-2 SS 304 0.187 4 0.125
factory for specifics E12-3 SS 304 0.125 4 0.063
E12-4 SS 304 0.375 4 0.125
* E12-5A Tantalum 0.250 4 0.125
E12-8 Inconel 0.250 4 0.125
E12-9 Copper 0.250 4 0.125
NOTES:
Example of Custom Design
• Gauge material same as test item for
minimum heat, char, erosion, and ablation
variations
• Two-dimensional accuracy at the point of
measurement
• Fast response times
• Temperature ranges to 5,000 degrees
Fahrenheit
• Pressure range to 3,000 psi
Applications:
• Material research and evaluation
• Insulation and char characteristics
• Rocket insulation and re-entry shields
• Temperature monitoring and control of
cooling apparatus
• Ablation, erosion and char rates
• Heat transfer and fusion point temperature of
materials
• Automotive brake band research
Specifications
Part No. Description
F2-1-(•) 2-Pole Plug, 400°F max.
F2-2-(•) 2-Pole Jack, 400°F max. • = Insert thermocouple calibration:
F2-3-(•) 2-Pole Plug, 800°F max.
F2-4-(•) 2-Pole Jack, 800°F max. B, C, CU, E, J, K, N, R, S, T
F2-5 (#) Tube Adaptor for 2-Pole Plug
F2-6 Cable Clamp for 2-Pole Jack
F2-7 (#) Dual Element for Tube Adaptor # = Specify sizes:
F2-8-(•) 3-Pole Plug, 400°F max. 0.062, 0.125, 0.187, 0.250, 0.375
F2-9-(•) 3-Pole Jack, 400°F max.
F2-10-(•) 3-Pole Plug, 800°F max.
F2-11-(•) 3-Pole Jack, 800°F max.
F2-12 (3) Tube Adaptor for 3-Pole Plug
F2-13 Cable Clamp for 3-Pole Jack
These connectors are color coded to thermocouple calibration and can be used in
ambient temperatures of a continuous 400 degrees Fahrenheit and intermittent 500 degrees
Fahrenheit. High temperature connectors are color coded ‘Red.’ With ambient temperatures
of a continuous 800 degrees Fahrenheit and intermittent 1,000 degrees Fahrenheit.
NOTES:
• Available in thermocouple calibration types:
E, CU, CX, J, K, N, SX & T
• Specify thermocouple calibration when
ordering.
Example: F4-7-K F
Specifications
Part No. Description
F4-4 Mini Jack Circuit Box, 2 Jacks
F4-5 Mini Jack Circuit Box, 3 Jacks For 800°F
F4-6 Mini Jack Circuit Box, 4 Jacks jacks, add
F4-7 Mini Jack Circuit Box, 5 Jacks suffix “-HT”
F4-8 Mini Jack Circuit Box, 6 Jacks
F4-9 Standard Jack Circuit Box, 400°F max. 1 Jack
F4-10 Standard Jack Circuit Box, 400°F max. 2 Jacks
F4-11 Standard Jack Circuit Box, 400°F max. 3 Jacks
F4-12 Standard Jack Circuit Box, 400°F max. 4 Jacks
F4-13 Standard Jack Circuit Box, 400°F max. 5 Jacks
F4-14 Standard Jack Circuit Box, 400°F max. 6 Jacks
F4-15 Standard Jack Circuit Box, 800°F max. 1 Jack
F4-16 Standard Jack Circuit Box, 800°F max. 2 Jack
F4-17 Standard Jack Circuit Box, 800°F max. 3 Jack
F4-18 Standard Jack Circuit Box, 800°F max. 4 Jack
F4-19 Standard Jack Circuit Box, 800°F max. 5 Jack
F4-20 Standard Jack Circuit Box, 800°F max. 6 Jack
NOTES:
• Utilizes DIN Transmitters and fits most terminal blocks. • Rated NEMA 4x & IP68
Specifications
Thread Size
Part No. Material
(PE x CE)
F7-1-1212-AL 1/2” x 1/2” NPT
F7-1-1234-AL Aluminum 1/2” x 3/4” NPT
F7-1-3434-AL 3/4” x 3/4” NPT
Our polypropylene heads are FDA approved and
F7-1-1212-SS 1/2” x 1/2” NPT
can be used for sanitary applications.
F7-1-1234-SS Stainless Steel 1/2” x 3/4” NPT
F7-1-3434-SS 3/4” x 3/4” NPT
F7-1-1212-PP 1/2” x 1/2” NPT
F7-1-1234-PP Polypropylene 1/2” x 3/4” NPT
F7-1-3434-PP 3/4” x 3/4” NPT
NOTES:
• Can accomodate standard DIN Transmitters and fits
most termnial blocks.
• Rated NEMA 4x & IP68
Specifications
Thread Size
Part No. Material
(P x C)
F7-12-1212-CI 1/2” x 1/2” NPT
F7-12-1234-CI Cast Iron 1/2” x 3/4” NPT
F7-12-3434-CI 3/4” x 3/4” NPT
F7-12-1212-AL 1/2” x 1/2” NPT
F7-12-1234-AL Aluminum 1/2” x 3/4” NPT
F7-12-3434-AL 3/4” x 3/4” NPT
Specifications
Thread Size
Part No. Material
(P x C)
F7-23-1212-AL 1/2” x 1/2” NPT
F7-23-1234-AL Aluminum 1/2” x 3/4” NPT
F7-23-3434-AL 3/4” x 3/4” NPT
Specifications
Part No. Description Probe Mount Thread
F7-24-1414-RTC 1/4” NPT
Standard 350°F
F7-24-3814-RTC 3/8” NPT
F7-24-1414-RTCHT 1/4” NPT
Hi-Temp 800°F
F7-24-3814-RTCHT 3/8” NPT
Terminal blocks are designed to connect temperature probes to existing extension cables.
They fit in a wide variety of sensor housings which include: aluminum, stainless steel, plastic
heads, etc. These terminal blocks may be available in various shapes (round, oval, hex) and
can provide 1, 2, 3, or 4 sets of poles to meet your specific installation requirements.
NOTES:
• Designed for: Single, Duplex, and Triplex
• Al2O3 - 45% Stronger than ceramic, resistant temperature sensors.
to cracking and flaking
• Other terminal blocks available upon
• Also available in Bakelite request, contact factory
F7-4-1 F7-4-1-DPX
F
F7-4-1-TRX F7-4-1-RTC
Specifications
Number
Part No. Material Shape
of Terminals
F7-4-1 Alumina Round 4
F7-4-1-DPX Alumina Round 4
F7-4-1-TRX Alumina Round 6
F7-4-1-RTC Bakelite Round 3
F7-4-2 Alumina Oval 2
Specifications
Order
Part No. Material Epoxy Color Thread Sizes (P x C)
Certification
F7-8-1212-AL 1/2” x 1/2” NPT
F7-8-1234-AL Aluminum Blue ATEX 1/2” x 3/4” NPT
F7-8-3434-AL 3/4” x 3/4” NPT
F7-8-1212-SS 1/2” x 1/2” NPT
F7-8-1234-SS SS316 - ATEX 1/2” x 3/4” NPT
F7-8-3434-SS 3/4” x 3/4” NPT
F7-9-1212-AL 1/2” x 1/2” NPT
F7-9-1234-AL Aluminum Silver FM & CSA 1/2” x 3/4” NPT
F7-9-3434-AL 3/4” x 3/4” NPT
F7-9-1212-SS 1/2” x 1/2” NPT
F7-9-1234-SS SS316 - FM & CSA 1/2” x 3/4” NPT
F7-9-3434-SS 3/4” x 3/4” NPT
Specifications
Number
Part No. Material Description Process Opening
of Terminals
F7-8380-2-18 Nickel-Plated 1/8” NPT
2 Canister Head
F7- 8380-2-14 Steel 1/4” NPT
F7- 8380-3-18 Nickel-Plated 1/8” NPT
3 Canister Head
F7- 8380-3-14 Steel 1/4” NPT
F7- 8380-4-18 Nickel-Plated 1/8” NPT
4 Canister Head
F7- 8380-4-14 Steel 1/4” NPT
Indicator Specifications
Display Black LCD w/4 digits including (-) sign
Digital Height ~ 0.5” (12mm)
Range Any range between (-) 1999 to 9999, 0 to 3 decimals
Under / Over Range Indicator Flashing Lo/Hi
Reponse Time Approximately 0.5s
Ambient operating temperature -25 to +70°C / -13 to +160°F
Accuracy +/-0.05% full scale +/- 1 digital, typical
Protection IP 66 / NEMA 4
Wiring Connection Stranded, < 16 AWG
NOTES:
• Two 3/4” NPT conduit Feed-Thru hubs offset for
maximum clearance and capacity.
• 7/16” thick base for blind tapped instrument mounting
holes in any location.
• Glass cover models have a large 2.5” diameter,
tempered glass window for local read out.
• Corrosion resistant, “safety blue” polyester
powder coating.
Specifications
Input Current 4-20 mA
Maximum Current 30 mA
Maximum Current ~3.5 mA
for Operation
Voltage Drop ~1.5 V
Indication
Display Black LCD with 4 digits including minus sign
Digit Height 12.7 mm/0.5”
Indication Range Any range between - 1999 to 9999
Decimals Selectable, 0 to 3
Upper Range / Over Range Flashing symbols LO/HI
Engineering Units Set of Labels included (including blanks)
Response Time Approximately 0.5 seconds
Scale Setting Two pushbuttons inside the housing
Operation Temperature -25 to +70°C / -13 to +158°F
Typical Accuracy ±0.05 % FS ±1 digit
Protection IP66 / NEMA 4
Connections Stranded, ≤ 1.5 mm2 AWG 16
Conduit Threads 2 x 3/4” NPT
Mounting Wall Mounting
Available in two materials, the standard material is good to 400 degrees Fahrenheit. The
high temperature material is good to 800 degrees Fahrenheit. All high temperature jacks
are color coded ‘red.’ All standard jacks are coded per thermocouple calibration. Standard
thermocouple calibration symbols and color codes are easily visible from the front.
NOTES:
• All panels are 3/32 inch steel frame.
• All thermocouple calibrations and copper jacks are available.
• For 800°F units, add suffix “-HT” for High Temperature, to the part
number. F
• Numbering sequence begins at 1 unless otherwise noted.
• Special panels with up to 240 circuits are available, contact factory.
• When ordering, specify part number and calibration.
Example: F8-2-K
Specifications
They have a low impedance reference source. Compatible with computer and process
controllers. All incorporating the characteristics of high accuracy, small size, low
power, instant operation, and rugged construction. This compensator is available with
soldered terminals for power and output signal and leads for thermocouple input with 2
mounting holes.
Specifications
Ordering Information
0.25°C @ 25°C ambient
Part No. Type 0.5°C @ 50°C ambient
Accuracy
0.75°C @ 75°C ambient
F11-7 J 1.0°C @ 100°C ambient
F11-8 K
F11-9 T Stability Better than 0.25°C at stabilized ambient between -54°C to 100°C
F11-10 R Reference Point 0°C standard
F11-11 S
F11-12 E Size 1” x 1” x 5/16” thick
F11-13 G Weight 10 grams
F11-14 C
F11-15 D Input Power 5 VDC standard
F11-16 B Power Consumption As low as 100 microwatts
Mounting (2) #6 screws
Dimensions
Special Ratings:
• For FM approved
device, add suffix “FM”
to the part number.
• For ATEX approved
device, add suffix
“ATEX” to the part
number.
Temperature Ranges and Specifications
• For HART compatible
communications device,
F
Pt100 (a=0.00385) -200 to 1000°C / -328 to 1832°F
Pt1000 (a=0.00385) -200 to 200°C / -328 to 392°F add suffix “HART” to the
Input RTD
PtX10 ≤X≤ 1000 (a=0.00385) Upper Range Depending on X-Value part number.
Pt100 (a=0.003902) -200 to 1000°C / -328 to 1832°F
3-,4-wire connection
Pt100 (a=0.003916) -200 to 1000°C / -328 to 1832°F • For FM or ATEX plus
Ni100 (1) -60 to 250°C / -76 to 482°F HART communication
Ni1000 (1) -10 to 150°C / 14 to 302°F add suffix “FM” or
Input
“ATEX” plus “HART” to
Potentiometer 3-,4-wire connection, 0 - 2000 Ω the part number.
Resistance Example: F11-50-FM-
HART, or F11-50-ATEX-
Input Thermocouples Types: B, C, E, J, K, N, R, S, T HART
Input mV -10 to 500 mV
Sensor Failure User Definable Output
Adjustments - Zero Any Value Within Range Limits
Minimum Spans 100° either F or C User Specified Information
(programmed by NANMAC)
Output 4-20 / 20-4 mA, Temperature Linear
Operating Temperature -40 to 85°C / -40 to 185°F 1) Input Sensor Type
Thermocouple EXTENSION grade wire (denoted by an “X”) has approximately the same
thermoelectric properties as thermocouple wire, but is only guaranteed accurate within a
limited temperature range. Typically, under 400 degrees Fahrenheit. All thermocouple wire
is supplied to your specified length.
### X ##
Part Number = Insulation Material Wire Size
G
- - - 812K20 812N20 - - -
Nextel braided (820) rated to 2,600°F
- - - - - - - -
- - 828J30 828K30 - - - -
- - - 828K28 - - - 828T28
Fiberglass braided (828) rated to 900°F - 828E24 828J24 828K24 828N24 828RX24 828SX24 -
828CX20 828E20 828J20 828K20 - 828RX20 828SX20 828T20
Since these cables have a relatively high internal impedance (up to 34 ohms) they should
not be used with low impedance type, analog panel meters. They are ideal for digital and
analog type indicators or controllers having an input resistance of 50 ohms or greater.
NOTES:
• Termination styles are available upon
• Tolerance of ±10% on length, diameter, and request.
resistance.
• Consult factory for coils other than 12
• Probes sold separately inches long and special requirements.
Specifications
Approximate
Part No. Type Color-Code Ohms / 12” (coiled)
Cable Diameter (in.)
G10B-1 J Black 16.5 0.180
G10B-2 K Yellow 27.5 0.180
G10B-3 T Blue 14.0 0.180
G10B-4 E Purple 33.5 0.180
G10B-5 RTDs or Thermistors White 0.60 0.180
Specifications
Thermocouple Sheath Sheath Wall Wire
Part No.
Type Material Diameter (in.) Thickness (in.) Diameter (in.)
G11-2 0.040 0.007 0.006
G11-3 0.062 0.010 0.010
G11-4 0.125 0.018 0.020
J SS 304
G11-5 0.188 0.025 0.032
NOTES: G11-6 0.250 0.036 0.040
G11-6A 0.080 0.015 0.014
• All cables will be G11-8 0.040 0.007 0.006
furnished to your G11-9 0.062 0.010 0.010
specified total length, G11-10 J Inco 600 0.125 0.018 0.020
plus or minus ten G11-11 0.188 0.025 0.032
percent. G11-12 0.250 0.036 0.040
• For other sizes, G11-14 0.040 0.007 0.006
alloys, and insulation G11-15 0.062 0.010 0.010
contact factory. G11-16
K SS 304
0.125 0.018 0.020
G11-17 0.188 0.025 0.032
• Multi-conductor cable G11-18 0.250 0.036 0.040
is available for most G11-18A 0.080 0.015 0.014
sheath sizes.
G11-20 0.040 0.007 0.006
• When ordering, G11-21 0.062 0.010 0.010
specify part number G11-22 K Inco 600 0.125 0.018 0.020
and length. G11-23 0.188 0.025 0.032
G11-24 0.250 0.036 0.040
• Minimum length
orders apply, contact G11-26 0.040 0.007 0.006
factory for you G11-27 0.062 0.010 0.010
specific requirement. G11-28 0.125 0.018 0.020
T SS 304
G11-29 0.188 0.025 0.032
• Thermocouple Type G11-29A 0.250 0.036 0.040
N is also available - G11-29B 0.080 0.015 0.014
Contact Factory G11-30 0.040 0.007 0.006
G11-31 0.062 0.010 0.010
G11-32 0.125 0.018 0.018
E SS 304
G11-33 0.188 0.025 0.032
G11-33A 0.080 0.015 0.014
G11-33B 0.250 0.036 0.040
G11-34 0.040 0.007 0.006
G11-35 E Inco 600 0.62 0.010 0.010
G11-36 0.125 0.018 0.020
Low cost, compact size thermometers features single or dual channel temperature
measurements with dual display (order probes separately).
Store up to 10,000 readings for each channel with a perpetual calendar real time function.
The unique CALL-FIT function allows you to read & search the desired log data from memory
at a speed of 50 pages per second. All the data collected by the data-logger during long-term
monitoring can be transmitted to computers for further analysis using Windows® software
(order probes separately).
NOTE:
• RTD models also available H
H1-80s - Common Specifications
Resolution -0.1°C / 0.1°F below 1,000°C / °F
Function °C/°F/K, MAX, MIN, AVG, HOLD, REL, LIMIT, Hi/Lo, TYPE,
COUNT, TIME, CLOCK, CHANNEL, T1-T2, T3-T4, BACK-
LIGHT, RS232, REC, CALL
Power Auto Power OFF
Interface Optional RS-232 interface with Windows®
Approval CE Approval, to ITS-90
H2-5BA
H2-5BA H2-5C H2-5D • Roller surface, right
angle St rollers for
moving or rotating
smooth surfaces (roller
diameter = 0.75 inch).
480°F
H2-5C
250°C
• Roller surface, bearing
rollers for smooth
plastic and steel pipe
plus moving or rotating
surfaces (roller diameter
= 0.63 inch).
H2-6A H2-8 H2-6 H2-5D
• Miniature teflon rollers
for moving or rotating
surfaces in food
480°F processing (roller
diameter = 0.63 inch).
250°C
H2-6A
• Magnetic surface probe
(one ribbon) allows for
sensor to be attached
to measuring target (no
handle).
H2-006 H2-005 H2-007 H2-3B H2-8
• Moving surface probe
ideal for measuring
moving or stationary flat
1,470°F metal or plastic surfaces.
800°C H2-6
• Magnetic surface
probe (three ribbon)
designed for stationary
surfaces, ideal for griddle
temperatures.
NOTES:
• Field selectable inputs
• 4-20 mA, ±10 V, thermocouple calibration
types: E, J, K & T and Pt100 RTD inputs
• NEMA 4X, IP 65 front panel
• Shallow depth case 3.5” behind panel
• Serial communication adaptor options
• Two form C 3 A relays option
• Selectable fail-safe operation
• Latching or non-latching
• Pump alteration control
• On & Off time delays
• 23 VDC @ 200 mA supply option
• Modbus® RTU option
• 4-20 mA output option
• Dual 24 VDC supplies option
Serial Communications
Specifications
Part No. Installed Options Power Required
H3-PD765-6R0-00 None 85-265 VAC
H3-PD765-6R0-10 24 VDC Supply Output 85-265 VAC
H3-PD765-6R2-00 2 Relays 85-265 VAC
H3-PD765-6R2-10 2 Relays & 24 VDC Supply Output 85-265 VAC
H3-PD765-6R3-00 4-20 mA Output 85-265 VAC
H3-PD765-6R3-10 4-20 mA Output & 24 VDC Supply Output 85-265 VAC
H3-PD765-6R3-20 4-20 mA Output & Dual 24 VDC Output 85-265 VAC
H3-PD765-7R0-00 None 13-36 VDC
H3-PD765-7R2-00 2 Relays 13-36 VDC
H3-PD765-7R3-00 4-20 mA Output 13-36 VDC
H32-50 - Specifications
Temperature Range -40°F to 600°F (-40°C to 320°C)
Resolution 0.1°F (-20 to 212°F) otherwise 1°F
Distance Ratio 8:1
Emissivity Fixed at 0.95
Accuracy ±2.5% or ±5°F (3°C) at 0 to 392°F, H32-60
otherwise ±3%
Power 9 Volt Battery x 1
Auto Power Off After 6 seconds once trigger is
released
Dimensions 5.2 x 2.6 x 1.3” (157 x 80 x 40mm)
Features:
• Laser sighting to pinpoint target area
• LCD display with backlighting
• Temperature Unit Switchable: °C or °F
• Auto data hold for 10 seconds with no
operation H
• Emissivity 0.30 to 1.00 adjustable
• Standard package: meter, instruction
manual, and battery Quick Comparison
(see full specifications above)
H32-60 - Specifications Part No. H32-50 H32-60
Temperature -40°F to 600°F -40°F to 932°F
Temperature Range -40°F to 932°F (-40°C to 500°C) Range (-40°C to 320°C) (-40°C to 500°C)
Resolution 0.1°F (-20 to 212°F) otherwise 1°F
Distance Ratio 10:1 Distance
8:1 10:1
Emissivity 0.30 to 1.00 adjustable Ratio
Accuracy ±2% at 0 to 392°F, otherwise ±3%
Emissivity Fixed at 0.95 0.30 to 1.00 adjustable
Power 9 Volt Battery x 1
Auto Power Off After 10 seconds with no operation ±2% at 0 to 392°F, ±2% at 0 to 392°F,
Accuracy
Dimensions 5.2 x 2.6 x 1.3” (157 x 80 x 40mm) otherwise ±3% otherwise ±3%
Specifications
Input Thermocouple Temperature
Acccuracy*
Type Type Range
B 32 to 3,300°F (0 to 1,800°C) > 400°C : ±0.15% FS ±1 digit
< 400°C : ±5% ±1 digit
C (W5) 32 to 4,200°F (0 to 2,300°C) ±0.2% FS ±1 digit
E -300 to 1,800°F (-199.9 to 999.9°C) > 0°C : ±0.1% FS ±1 digit
J -300 to 2,300°F (-199.9 to 999.9°C) < 0°C : ±0.2% FS ±1 digit
K 0 to 2,300°F (-199.9 to 999.9°C) > 0°C : ±0.1% FS ±1 digit
L -300 to 1,600°F (-199.9 to 900.0°C) > 0°C : ±0.25% FS ±1 digit
Thermocouple
N -300 to 2,400°F (-200 to 1,300°C) > 0°C : ±0.1% FS ± digit
< 0°C : ±0.25% FS ±1 digit
Platinel II 32 to 2,500°F (0 to 1,390°C) ±0.1% FS ± digit
R
S
32 to 3,100°F (0 to 1,700°C)
32 to 3,100°F (0 to 1,700°C)
±0.15% FS ±1 digit H
T -300 to 750°F (-199.9 to 400.0°C)
U -300 to 750°F (-199.9 to 400.0°C)
JPtA -199.9 to 999.9°F (-199.9 to 500.0°C) ±0.1% FS ±1 digit**
JPtB -199.9 to 300.0°F (-150.0 to 150.0°C)
RTD PtA -300 to 1,560°F (-199.9 to 850.0°C) ±0.1% FS ±1 digit**
PtB -199.9 to 999.9°F (-199.9 to 500.0°C)
PtC -4.0 to 212.0°F (-19.99 to 99.99C) ±0.2% FS ±1 digit
0.4 to 2.0V 0.400 to 2.000 ±0.1% FS ±1 digit
1.000 to 5.000 1.000 to 5.000 Display range can be scaled between -1999 and 9999.
Process 0 to 10V 0.00 to 10.00 4 to 20 mA Input
-10 to 20mV -10.00 to 20.00 To accept a 4 to 20 mA signal, select 0.4 to 2.0 VDC input
0 to 100mV 0.0 to 100.0 and connect a 100Ω resistor across the input terminals.
Our standard RTD probe uses a 100 ohm platinum element with alpha = 0.00385. Sheath
material is SS 304 and can be 1/16, 1/8, 3/16, or 1/4 inch diameter in standard length of
five inches. Units are available with either a standard size plug or teflon insulated lead wire.
When ordered with a plug; the plug has three prongs. Units with lead wire can be either two
or three conductor. Available with stainless steel overbraid for added durability.
Two-Wire Leads
Three-Wire Leads
Three-Prong Plug
1/16 and 1/8 inch diameter units have a transition between sheath and leads
Specifications
Termination Stainless Steel
Part No. Probe OD
Styles Overbraid Pt1000 also available
I6-20 3/16 No
I6-21 1/4 No
I6-22 3/16 Yes NOTES:
I6-23 1/4 Two-Wire Yes
I6-23A 1/8 Leads No • Various size mounting bushings are
I6-23B 1/8 Yes available for these units.
I6-23C 1/16 No • Longer sheath or lead wire lengths,
I6-23D 1/16 Yes four-wire units, and various sheath
I6-24 3/16 No materials are available.
I6-25 1/4 No
I6-26 3/16 Yes • A variety of termination styles are
I6-27 1/4 Three-Wire Yes available for these units.
I6-27A 1/8 Leads No • Typical construction does not allow
I6-27B 1/8 Yes for bending; contact factory if your
I6-27C 1/16 No requirement involves bending.
I6-27D 1/16 Yes
I6-28 3/16
• PFA Teflon® encapsulation - good to
I6-29 1/4 Three Prong 450°F, can be added to any probe.
N/A
I6-31A 1/8 Plug
I6-31B 1/16
The standard probe contains Pt100 ohm RTD assembly with an aluminum general purpose
(GP) head. A terminal block is mounted on the interior of the GP head. The GP head has
1/2” NPT threads where the probe is mounted and a 1/2” NPT conduit outlet for your wire
connections. This RTD assembly is also available with a four inch long stainless steel support
tube for use with ceramic sheaths and adjustable mounting fittings. The support tube is an
1/8” larger in diameter than the sheath diameter. When ordering with support tube add the
suffix (ST) to the part number. Standard support tube is four inches long and can be made
to most any length required, mounting bushing is eliminated when ST is applied.
NOTES:
Specifications
• Types available: Pt100, Pt1000
Sheath Sheath
• Typical construction does not allow for bending, Part No.
Diameter Material
contact factory if your requirement involves bending. I7-1 0.062
• All sensors use two wire leads, three or four wire I7-2 0.125
SS 304
assemblies are also available. I7-3 0.187
Units are made with stainless steel glands and have either
O-ring (OR series), pipe thread (A series), or conical (HP
series) metal-to-metal seals. They can be rated for use from
low vacuum to 20,000 psi and temperatures to 500 degrees
Fahrenheit. All standard glands contain #24 gage (0.020”)
AWG solid copper conductors inside an 1/8 inch diameter
stainless steel tube. These copper conductors are insulated
from each other and the tube wall by a high temperature
ceramic. The 1/8 inch stainless steel tubes containing the
copper conductors are flexible and can be bent to most
any desired angle in a radius as small as 1/2 inch. The
stainless steel tube provides excellent shielding for each pair
of conductors against unwanted electromagnetic noise or
stray voltage pickup. These tubes, when more than one, are
staggered in length.
All standard pressure and amperage ratings are based on 68°F conditions.
Specifications
Pressure
Part No. Conductors B C D E-thd E-hex F G H L
Rating (psi)
K6-1 2 1-7/16 13/32 7/16-20 3/4 1/8 - - -
K6-2A 4 2 15/32 3/4-16 1-5/16 1/8 - - -
5,000 psi As
K6-2B 6 2 15/32 3/4-16 1-5/16 1/8 - - -
(OR Series) Required
K6-2C 8 2 15/32 3/4-16 1-5/16 1/8 - - -
K6-2D 10 2 15/32 3/4-16 1-5/16 1/8 - - -
K6-6 2 27/32 3/8 1/8” NPT 7/16 1/8 - - -
K6-7 4 2 3/4 1/2” NPT 7/8 1/8 - - -
3,200 psi As
K6-8 6 2 3/4 1/2” NPT 7/8 1/8 - - -
(A Series) Required
K6-9 8 2 3/4 1/2” NPT 7/8 1/8 - - -
K6-10 10 2 3/4 1/2” NPT 7/8 1/8 - - -
K6-11
K6-12
10,000 psi
2
4
3
3
As
1.25
1.25
1-1/8-12
1-1/8-12
1-3/16
1-3/16
1/8
1/8
0.250
0.250
0.560
0.560
1
1 K
K6-13 6 3 1.25 1-1/8-12 1-3/16 1/8 0.250 0.560 1
(HP Series) Required
K6-14 8 3 1.25 1-1/8-12 1-3/16 1/8 0.250 0.560 1
K6-15 10 3 1.25 1-1/8-12 1-3/16 1/8 0.250 0.560 1
Temperature Range and Accuracy Tolerance of Commonly Used Thermocouples & RTDs
Thermocouple Type RTD
Range
B C D E J K N R S T Pt100
°C 0/1700 0/2320 0/2320 -200/900 0/750 -200/1250 -270/1300 0/1450 0/1450 -200/350 -200/850
°F 32/3092 32/4230 32/4230 -328/1652 32/1382 -328/2282 -454/2372 32/2642 32/2642 -328/662 -328/1562
°C / °F Accuracy (tolerance) is ± the values stated below. Values are percent of temperature, unless otherwise specified.
-200/-328 - - - 1.0 - 2.0 2.0 - - 1.5 0.65
-100/-148 - - - 1.0 - 2.0 2.0 - - 1.5 0.8
0/32 - - - 1.0 0.75 0.75 0.75 0.25 0.25 1.5 0.3
200/392 - - - 0.5 0.75 0.75 0.75 0.25 0.25 1.0 0.8
400/752 - 4.5°C 4.5°C 0.5 0.75 0.75 0.75 0.25 0.25 1.0 0.55
600/1112 - 1.0 1.0 0.5 0.75 0.75 0.75 0.25 0.25 - 0.55
800/1472 0.5 1.0 1.0 0.5 - 0.75 0.75 0.25 0.25 - 0.55
1000/1832 0.5 1.0 1.0 - - 0.75 0.75 0.25 0.25 - -
1200/2192 0.5 1.0 1.0 - - 0.75 0.75 0.25 0.25 - -
1400/2552 0.5 1.0 1.0 - - - - 0.25 0.25 - -
1600/2912 0.5 1.0 1.0 - - - - - - - -
1800/3272 - 1.0 1.0 - - - - - - - -
2000/3632 - 1.0 1.0 - - - - - - - -
2300/4172 - 1.0 1.0 - - - - - - - -
NOTES:
• Values are in an accordance with NIST Monograph 175, Revised to ITS 90
• Accuracy Values for Pt100 RTD are not to exceed values.
• All values shown are for Standard Limits of error class B limits.
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27 Hi-Temp. Eco. with GP Head (A11B Series) 24
Hi-Temp. Eco. with GP Head (A11B Series) 24 Ceramic Sheath TCs (A35 Series) 51
Ceramic Sheath TCs (A35 Series) 51 Glass (molten)
Furnaces (vacuum) Hvy. Duty TCs (A33 Series) 49
Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26 Gradient Temperature Studies
Hi-Temp. Eco. with Plug (A11A Series) 23 Surface & In-Wall TCs (E6 Series) 75
Hi-Temp. TCs (tungsten coated) (A12D Series) 30 Eroding TCs (E12 Series) 77
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27 Multi-Function Sensor (E13 Info) 78
Hi-Temp. Eco. with GP Head (A11B Series) 24 Bare Wire TCs (A13 Series) 31
Ceramic Sheath TCs (A35 Series) 51
Gun Barrel Bore Surfaces
Gases Surface & In-Wall TCs (E6 Series) 75
Ribbon TCs (C2 Series) 61 Eroding TCs (E12 Series) 77
Ribbon TCs (flowing) (C5 Series) 63
Heat Transfer Studies
Ribbon TCs (sanitary) (C6 Series) 64
Surface & In-Wall TCs (E6 Series) 75
Gases (high velocity) Eroding TCs (E12 Series) 77
Ribbon TCs (C2 Series) 59 Multi-Function Sensor (E13 Info) 78
Ribbon TCs (flowing) (C5 Series) 63 Bare Wire TCs (A13 Series) 31
Multi-Function Sensor (E13 Info) 78
Industrial
Gases (in pipelines) Standard TCs with Plugs (A8A Series) 11
Ribbon TCs (C2 Series) 61 TCs with Connector Heads (A8E Series) 15
Ribbon TCs (flowing) (C5 Series) 63 Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26
Flared Union TCs (D3 Series) 70 Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27
Pipe-Thread Union TCs (D4A Series) 72 Hvy. Duty TCs (A33 Series) 49
Eco. Union TCs (D7 Series) 74 Ceramic Sheath TCs (A35 Series) 51
Flared Union RTDs (D3 Series) 70 Pipe-Angle Ext. (A34 Series) 50
Tube Union RTDs (D4 Series) 71
Internal Surface Temperatures
Pipe-Thread Union RTDs (D4A Series) 72
Surface & In-Wall TCs (E6 Series) 75
Ribbon TCs for Sanitary Use (C6 Series) 64
Eroding TCs (E12 Series) 77
General Purpose (+2,400°F) Ribbon TCs (C2 Series) 61
TCs with No Connectors (A8 Series) 10
Kilns
Standard TCs with Plugs (A8A Series) 11
TCs with No Connectors (A8 Series) 10
TCs with Flexible Leads (A8B Series) 12
Bare Wire TCs (A13 Series) 31
TCs with Armor Leads (A8C Series) 13
Unsheathed TCs (A14A Series) 33
TCs with Connector Heads (A8E Series) 15
Ceramic Sheath TCs (A35 Series) 51
Hvy. Duty TCs (A33 Series) 49
Ceramic Insulators (A14 Series) 32
General Purpose (high temperature) Mullite Protection Tubes (A30 Series) 46
Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26 Ceramic and Refractory Tubes (A31 Series) 47
Hi-Temp. Eco. with Plug (A11A Series) 23
Mixer
Hi-Temp. TCs (tungsten coated) (A12D Series) 30
Mixer TCs & RTDs (C10 Series) 67
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27
Hi-Temp. Eco. with Plug (A11A Series) 23 Eroding TCs (E12 Series) 77
Hi-Temp. TCs (tungsten coated) (A12D Series) 30 Multi-Function Sensor (E13 Info) 78
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27 Wires (moving)
Hi-Temp. Eco. with GP Head (A11B Series) 24 Rub & Contact TCs (B6 Series) 56
Ceramic Sheathed TCs (A35 Series) 51
Soaking Pit
Hvy. Duty TCs (A33 Series) 49
Pipe-Angle Ext. (A34 Series) 50
Protection Tubes (A32 Series) 48
Thermocouple Wire
Insulated Ext. Wire (G9 Series) 99
Type B 99
Type C 99
Type E 99
Type J 99
Type K 99
Type R 99
Type S 99
Type T 99
Thermowells
General Use T-wells (A21A Series) 37
T-wells with Lag Ext. (A22A Series) 38
T-wells (3/8”) (A23 Series) 39
T-wells (3/8” with Lag Ext.) (A24A Series) 40
T-wells (Hvy. Duty Taper) (A25 Series) 41
T-wells (Hvy. Duty with Lag Ext.) (A26A Series) 42
Flanges for T-wells (A27 Series) 43
T-wells for Flanges (A28 Series) 44
T-wells (Limited Space) (A29 Series) 45
Mullite Protection Tubes (A30 Series) 46
Ceramic and Refractory Tubes (A31 Series) 47
Protection Tubes (A32 Series) 48
Compression Fittings for T-wells (A10 Series) 21
Temperature Transmitters
Non-Isolated (Head Mount) (F11-40 Series) 95
Non-Isolated (Rail Mount) (F11-40RM Series) 96
In-Head Displays (F7-LCD Series) 90
In-Head Displays (NEMA) (F7-LCD-SP Series) 91
Wear Rates
Surface & In-Wall TCs (E6 Series) 75
USE & PERFORMANCE: The determination as to the performance and/or adaptability of any of the
Seller’s products or materials to the specific needs and requirements of the purchaser is solely the
purchaser’s responsibility. The seller’s engineering department will gladly offer suggestions and
provide physical and electrical characteristics of commonly used materials, as they are available.