Download as pdf or txt
Download as pdf or txt
You are on page 1of 124

Table of Contents

Commonly used abbreviations & symbols


EP = Explosion Proof Ext = Extension GP = General Purpose Hvy = Heavy Duty TC = Thermocouple
T-well = Thermowell WP = Weatherproof MW = Mini-Weatherproof RTD = Resistance Temperature Detector

Description Series Page


Spring-Loaded Bayonet TCs A5 4
Adjustable Bayonet TCs A5A 5
Washer TCs with Flexible Leads A6 6
Spring-Loaded Bayonet Ribbon TCs A6A 7
Sharp Tip TCs with Coil Cord A6B 8
Bolt-Down TCs with Flexible Leads A7 9
TC Probes with One Inch of Bare Leads A8 10
TC Assemblies with Standard Size Connector A8A 11
TC Assemblies with Flexible Fiberglass Leads A8B 12
GP TC Probes with Armor A8C 13
GP TC Probes with Extensions A8D 14
TC Assemblies with GP Heads A8E 15
TC Assemblies with Miniature Plugs Attached A8F 16
Teflon Tubing and Encapsulation A8G 17
TC Ext. Assemblies A8H 18
RTD Cable Assemblies A8H-RTD 19
TC Terminations A9 20
Adjustable Compression Fittings A10 21
Hi-Temp. TC Probes (Information) A11 22
Hi-Temp. TC Probes (#30 gauge Standard Connector) A11A 23
Hi-Temp. TC Probes (#30 gauge Conduit Head) A11B 24
Hi-Temp. TC Probes (#30 gauge Flex Leads) A11C 25
Hvy. Duty Hi-Temp. TC Probes (#24 gauge Standard Connector) A12 26
Hvy. Duty Hi-Temp. TC Probes (#24 gauge Conduit Head) A12A 27
Hvy. Duty Hi-Temp. TC Probes (#24 gauge Flex Leads) A12B 28
Hvy. Duty Hi-Temp. TC Probes (20,000 psi) A12C-EQ 29
Hi-Temp. TC (tungsten coated) A12D 30
Bare Wire TC Elements A13 31
TC Insulators A14 32
Industrial Base Metal TC with Connector A14A 33
Flexible TC and Ext. Wire Assemblies A14B 34
T-well Assemblies General Information A17 35
General Use T-wells A21A 37
T-wells with Lag. Ext. A22A 38
T-wells (3/8”) A23 39
T-wells (3/8” with Lag. Ext.) A24A 40
T-wells (Hvy. Duty Tapered) A25 41
T-wells (Hvy. Duty with Lag. Ext.) A26A 42
Flanges for T-wells A27 43
T-wells for Flanges A28 44
T-wells (Limited Space) A29 45
Mullite Protection Tubes A30 46
Ceramic and Refractory Tubes A31 47
Protection Tubes A32 48
Hvy. Duty TC Assemblies with Protection A33 49
Angle Type Ext. Assemblies A34 50
TC with Ceramic Protection Tubes A35 51
NC-11 Advanced TC Assemblies for Molten A37 52
Advanced TC Assemblies for Molten Aluminum A38 53
Ribbon TCs Exposed B2 54
Ribbon & Weldable Tab TCs for Surface Temps. B4 55
Rub & Contact TCs Ideal for Moving Surfaces B6 56
Ribbon TCs with Retractable Shield B7 57
Handheld TCs for Surface Contact Measurement B8 58
(Continued next page)

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 1


Table of Contents
Commonly used abbreviations & symbols
EP = Explosion Proof Ext = Extension GP = General Purpose Hvy = Heavy Duty TC = Thermocouple
T-well = Thermowell WP = Weatherproof MW = Mini-Weatherproof RTD = Resistance Temperature Detector

Spring-Loaded Ribbon TCs B9 59


Right-Angle Ribbon TCs (immersion temps.) C1 60
Right Angle Ribbon TCs (hi-pressure apps.) C2 61
Extruder TCs for Plastic Melt Temps. C2B 62
Right-Angle Ribbon TCs with Dust Deflector C5 63
Right-Angle Ribbon TCs for Sanitary Apps. C6 64
Extrude-O-Couple (Information) C8 65
TC for In-Stream Plastic Melt C8A 66
Mixer Temp. Sensors for Sanitary Apps. C10 67
Mixer TC Mounting Accessories C11 68
Flow-Thru TCs & RTDs (Information) D1 69
Flow-Thru TCs & RTDs (Flared Unions) D3 70
Flow-Thru TCs & RTDs (Comp. Fit. Tube Unions) D4 71
Flow-Thru TCs & RTDs (NPT Unions) D4A 72
Hose Clamp TCs D6 73
Econ. Pipe-Line TCs & RTDs D7 74
Surface and In-Wall TCs (Self-Renewing) E6 75
Self-Renewing TC (Information) E11 Info 76
Self-Renewing TCs E12 77
Multifunction Sensor (Information) E13 Info 78
Standard 2-Pole & 3-Pole Connectors F2 79
Miniature Plugs & Jacks F3 80
Circuit Boxes F4 81
Conduit Heads F6 info 82
Conduit Heads GP F7-1 83
Conduit Heads Weatherproof (WP) F7-12 84
Conduit Heads Flip Top F7-23 85
Conduit Heads Miniature Weatherproof (MW) F7-24 86
Terminal Blocks for Conduit Heads F7-4 87
Conduit Heads Explosion Proof (EP & ATEX) F7-8/F7-9 88
Canister Heads F7-8380 80
Head Mount Digital Displays (4-20 mAmp) F7-LCD 90
Hvy. Duty Head Mount Indicator (4-20 mAmp) F7-LCD-SP 91
Conduit Heads Explosion Proof (EP) F7-NEMA-WINDOW 92
Jack Panels F8 93
TC Reference Junction F11 94
Head Mount Transmitters (Standard) F11-40 95
Rail Mount Transmitters Standard F11-40RM 96
Head Mount Transmitters (Isolated) F11-50 97
Rail Mount Transmitters Isolated F11-50RM 98
TC Ext. Wire G9 99
Multi-Pair TC Cable G10A 100
Coil Cord Cable for TCs and RTDs G10B 101
Mineral Insulated TC Cable G11 102
Digital Thermometers and Data Loggers H1 103
Handheld TC Probes for Moving Surfaces H2 104
Digital Displays & Controllers H3 105
TC Simulator / Calibrator H14-KIT 106
Infrared Thermometers H32 107
Temp. and Process Controllers H34 108
RTD Probes with Various Termination Styles I6 110
RTD Assemblies with GP Heads I7 111
Electrical Feed-Thrus for TCs or Other Signals K6 112

2 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Tab Index
A Series - Thermocouples, Thermowells & Flanges
Bare Wire, Sheathed & Heavy Duty Thermocouples, Thermowells &
Flanges Ceramic Insulators, Protection Tubes, Refractory & Ceramic
A
(sheathed, unsheathed & multiple sheathed)

B Series - Flexible Ribbon


Thermocouples for surface, air, and liquid temperatures B
(fast response times)

C Series - Ribbon sensors for air, liquids, plastics


Thermocouples for gas, liquid, and surface measurements without
conduction errors. Injection molding and extrusion applications
C
(fast response times)

D Series - Flow-Thru sensors for gases & liquids


Thermocouples & RTDs for tube and pipeline usage D
(fast response times)

E Series - Self-Renewing sensors for Eroding & Ablative surfaces


Reusable Ribbon Thermocouples for surface temperatures. Ideal
for heat transfer measurements. Material evaluation and surface
E
temperatures of any wall or structure (fast response times)
F Series - Connectors, 4-20 mAmp Transmitters, Panel Jacks
Thermocouples & RTDs (standard and miniature sizes), Conduit
Heads, Terminal Blocks, Jack Panels, Jack Boxes, Terminal Strips,
F
Terminal Lugs, and Reference Junctions

G Series - Thermocouple Wire


Insulated, bare, and multi-pair thermocouple cable
G

H Series - Instrumentation
Data Loggers, Handhelds, Indicators, Infrared Pyrometers, H
Recorders, and Temperature Controllers, 1/8, 1/4 DIN

I Series - RTDs
Sensors with leads, plugs, and conduit heads
I

K Series - Feed-Thrus
Thermocouple and Instrumentation, Vacuum & High Pressure
K

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 3


Spring-Loaded Bayonet Thermocouples
A5 Series

NOTES: • All standard units have 36 inches armored


extension leads.
• Available thermocouple types: E, J, K, N & T
• All bayonet thermocouples are supplied
• All standard units have a grounded junction. without adaptors and connectors.
If ungrounded junction desired, add “U” to
the Part No. • Specify thermocouple calibration as follows.
Example: A5-1-K, for type K

Model 00 Model 45 Model 90

Specifications
Adaptor
Length Length
Part No. Model Part No. Model
“A” (in.) “A” (in.)
A5-1 2 A5-19 2
A5-2 2-1/2 A5-20 2-1/2
A5-3 3 A5-21 3
A5-4 3-1/2 A5-22 3-1/2
A5-5 00 4 A5-23 90 4
A5-6 4-1/2 A5-24 4-1/2
A5-7 5 A5-25 5
A5-8 5-1/2 A5-26 5-1/2
A5-9 6 A5-27 6
A5-10 2
A5-11 2-1/2
Instructions for A5-12 3
Hole Depth and Adaptors A5-13 3-1/2
A5-14 45 4
Length “A” Specify thermocouple calibration
Depth A5-15 4-1/2
“B” (in.) 7/8” long 1-3/8” long 2-1/2” long A5-16 5
Adaptor Adaptor Adaptor A5-17 5-1/2 All standard units have 36” armored
A5-18 6 extension leads.
1/2 to 1 2 2-1/2 3-5/8
1 to 1-1/2 2-1/2 3 4-1/2 Mounting Adaptors All bayonet thermocouples are
1-1/2 to 2 3 3-1/2 4-5/8 supplied without adaptors and
A5-28 7/8
2 to 2-1/2 3-1/2 4 5-1/8 connectors.
A5-29 1/8 NPT 1-3/8
2-1/2 to 3 4 4-1/2 5-5/8
A5-30 2-1/2
3 to 3-1/2 4-1/2 5 6-1/8
3-1/2 to 4 5 5-1/2 6-5/8 A5-31 7/8
4 to 4-1/2 5-1/2 6 7-1/8 A5-32 3/8-24 NF 1-3/8
4-1/2 to 5 6 6-1/2 7-5/8 A5-33 2-1/2

4 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Adjustable Bayonet Thermocouples
A5A Series

The A5A Bayonet Thermocouple allows simple,


rapid adjustment of the immersion length to each
A
application. The thermocouple can be specified
with a bayonet cap on either an eight inch spring
to allow for up to seven inches of adjustable
immersion; or on the flexible armor to allow for
full “B” length adjustable immersion.

NOTES:
• Spring or armor adjustable provide wide
versatility • Longer lengths are available
• Fiberglass insulation offers protection to the • When ordering, specify style & type
wire Example: A5A-10-J, for type J

Spring Adjustable Style

Armor Adjustable Style

Specifications
Part No. Style Lead Wire Terminations
A5A-10 Bayonet cap on 8” spring 60” length Stripped wires 3” long
A5A-15 Bayonet cap on 12” spring 60” length Stripped wires 3” long
A5A-20 Bayonet cap on flexible armor 60” length Male thermocouple connector

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 5


Washer Thermocouples
with Flexible Leads
A6 Series

Washer thermocouples are designed to measure true average temperature of the washer.
Conduction errors are minimized by welding the thermocouple elements at 180 degrees.

NOTES:
• If lead lengths longer than 36 inches are
• Similar units are available using split lock required, specify your length requirement.
washers.
• Standard insulation material is fiberglass
• Termination styles: bare wire, standard size, (which is good to 900 degrees
or mini connectors are available. Fahrenheit operation).

Specifications
Washer Washer
Part No. Type Part No. Type
ID (in.) OD (in.) ID (in.) OD (in.)
A6-1 J 1/8 5/16 A6-11 K 1/8 5/16
A6-2 J 3/16 7/16 A6-12 K 3/16 7/16
A6-3 J 1/4 5/8 A6-13 K 1/4 5/8
A6-4 J 3/8 7/8 A6-14 K 3/8 7/8
A6-5 J 1/2 1-1/4 A6-15 K 1/2 1-1/4
A6-6 T 1/8 5/16 A6-16 E 1/8 5/16
A6-7 T 3/16 7/16 A6-17 E 3/16 7/16
A6-8 T 1/4 5/8 A6-18 E 1/4 5/8
A6-9 T 3/8 7/8 A6-19 E 3/8 7/8
A6-10 T 1/2 1-1/4 A6-20 E 1/2 1-1/4

6 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Spring-Loaded Bayonet Ribbon Thermocouples
A6A Series

Our Spring-Loaded Bayonet Ribbon Thermocouples


are designed to improve accuracy on in-wall temperature
A
measurements. A conventional spring-loaded bayonet
type thermocouples has large inherent errors, especially
in shallow-depth applications. These errors are due to the
conduction of heat, along the thermocouple sheath.

These ribbon bayonet thermocouples eliminate errors by


using an exposed ribbon thermal junction at the sensing tip
which is always in intimate contact with the bottom of the
blind hole. Because of this specially designed sensing tip,
these thermocouples eliminate errors caused by gradient
and conduction along the thermowell.

Model 00 Model 45 Model 90

Specifications Ribbon Tip Adaptor

Length Length
Part No. Model Part No. Model
“A” (in.) “A” (in.)
A6A-1 00 2 A6A-19 90 2
A6A-2 00 2-1/2 A6A-20 90 2-1/2
A6A-3 00 3 A6A-21 90 3
A6A-4 00 3-1/2 A6A-22 90 3-1/2
A6A-5 00 4 A6A-23 90 2
A6A-6 00 4-1/2 A6A-24 90 2-1/2
A6A-7 00 5 A6A-25 90 3 Length “A”
A6A-8 00 5-1/2 A6A-26 90 3-1/2 Depth
“B” (in.) 7/8” long 1-3/8” long 2-1/2” long
A6A-9 00 6 A6A-27 90 6
Adaptor Adaptor Adaptor
A6A-10 45 2
1/2 to 1 2 2-1/2 3-5/8
A6A-11 45 2-1/2 Specify thermocouple calibration
1 to 1-1/2 2-1/2 3 4-1/2
A6A-12 45 3
1-1/2 to 2 3 3-1/2 4-5/8
A6A-13 45 3-1/2 All standard units have 36” armored
2 to 2-1/2 3-1/2 4 5-1/8
extension leads.
A6A-14 45 4 2-1/2 to 3 4 4-1/2 5-5/8
A6A-15 45 4-1/2
All bayonet thermocouples are 3 to 3-1/2 4-1/2 5 6-1/8
A6A-16 45 5
supplied without adaptors and 3-1/2 to 4 5 5-1/2 6-5/8
A6A-17 45 5-1/2
connectors. 4 to 4-1/2 5-1/2 6 7-1/8
A6A-18 45 6 4-1/2 to 5 6 6-1/2 7-5/8

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 7


Sharp Tip Thermocouples
with Coil Cord
A6B Series

This tire probe is a grounded


thermocouple located at the tip
of a sharp-pointed stainless steel
probe. The 0.040” diameter
by 0.1” long probe is rigidly
bonded to the plastic handle.
Penetration is automatically
limited to 1/8 inch maximum by
the 1/4 inch diameter stainless
steel shoulder. Response times
of about one second are easily obtained by this probe. All probe assemblies come fully
assembled with a plastic handle, stress relief spring, 12” of retractable extension lead and a
miniature male 2-prong connector.

Monitor the temperature of semisoft materials such as: tires, plastics, food, etc.

Specifications
Part No. Type
A6B-30 K

8 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Bolt-Down Thermocouples
with Flexible Leads
A7 Series
A

The Bolt-Down Thermocouple contains #20 gauge (0.032”) solid conductors with fiberglass
insulation over each leg and fiberglass insulation overall. The fiberglass insulation has a
maximum service temperature of 900 degrees Fahrenheit. The ‘Bolt-Down’ thermocouple
is ideal for bolting it to a wall. Four standard sizes are available (#6, #8, #10, and #1/4”
eyelets). In addition to bolting the thermocouple to a wall, it can also be hooked to a traveling
conveyor or hung from a ceiling or hook.
NOTES:
• Standard lengths are 36 inches (longer
• Fiberglass insulation is standard. lengths available upon request).
• Bolt-Down thermocouples available in four • Choose from termination styles: bare leads,
standard thermocouple types J, T, K, and E. 2-pole connector, or spade plugs.

Bare Leads Standard Plugs Spade Lugs Mini Plug

A7 A B C D E F
Type Insulation Stainless Steel Length Termination Eyelet
Overbraid
1=J 1 = Fiberglass 1 = None 1 = Grounded 1 = Bare Leads A = #6 (.145”)
2=K 2 = Teflon 2 = Yes 2 = Ungrounded 2 = Stand Plug B = #8 (.170”)
3=T 3 = Nextel 3 = Spade Lugs C = #10 (.195”)
4=E 4 = Mini Plug D = 1/4 (.290”)
When ordering, specify Part No. and fill in the 4 letter blocks
Example: A14A-2-20-K-24 (specifies a Style 2 duplex thermocouple with 20 gauge Type K elements and length of 24 inches.

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 9


Thermocouple Probes
with One Inch of Bare Leads
A8 Series

Probes can be supplied spring loaded or with fixed mounted fittings. All fittings are 304
stainless steel with 1/2 inch NPT for mounting into: walls, connector heads, or thermowells.
The (SL - spring loaded) units allow up to 3/4 inch of travel. The (W - welded) units have the
1/2 inch NPT fitting brazed to the probe. All replacement units are supplied with one inch of
bare leads.
• Keep in mind that either Spring-Loaded (SL) or
NOTES: Welded (W) bushings utilize approximately two
inches of the sheath length. Please account for
• Duplex junctions units are available on this when specifying length.
all models except 1/16 inch diameter
units. Contact factory for more • PFA Teflon® encapsulation - good to 450°F, can
information. be added to any probe.

Exposed Junction Grounded Junction Ungrounded Junction

Thermocouple calibration type N is available in all sizes.


304 Stainless Steel Sheath - Specifications Inconel 600 Sheath - Specifications

Sheath Exposed Grounded Ungrounded Exposed Grounded Ungrounded


Junction Junction Junction Sheath Junction Junction Junction
Type Diameter Type
Diameter
(in.) Part No. Part No. Part No. Part No. Part No. Part No.
J 0.062 A8-1A A8-17 A8-33 J 0.062 A8-49 A8-65 A8-81
J 0.125 A8-2A A8-18 A8-34 J 0.125 A8-50 A8-66 A8-82
J 0.187 A8-3A A8-19 A8-35 J 0.187 A8-51 A8-67 A8-83
J 0.250 A8-4A A8-20 A8-36 J 0.250 A8-52 A8-68 A8-84
K 0.062 A8-5A A8-21 A8-37 K 0.062 A8-53 A8-69 A8-85
K 0.125 A8-6A A8-22 A8-38 K 0.125 A8-54 A8-70 A8-86
K 0.187 A8-7A A8-23 A8-39 K 0.187 A8-55 A8-71 A8-87
K 0.250 A8-8A A8-24 A8-40 K 0.250 A8-56 A8-72 A8-88
E 0.062 A8-9A A8-25 A8-41 E 0.062 A8-57 A8-73 A8-89
E 0.125 A8-10A A8-26 A8-42 E 0.125 A8-58 A8-74 A8-90
E 0.187 A8-11A A8-27 A8-43 E 0.187 A8-59 A8-75 A8-91
E 0.250 A8-12A A8-28 A8-44 E 0.250 A8-60 A8-76 A8-92
T 0.062 A8-13A A8-29 A8-45 T 0.062 A8-61 A8-77 A8-93
T 0.125 A8-14A A8-30 A8-46 T 0.125 A8-62 A8-78 A8-94
T 0.187 A8-15A A8-31 A8-47 T 0.187 A8-63 A8-79 A8-95
T 0.250 A8-16A A8-32 A8-48 T 0.250 A8-64 A8-80 A8-96

10 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Thermocouple Assemblies
with Standard Size Connector Attached
A8A Series
ets 50!
e
M 27 A
S
AM

This thermocouple probe comes with the appropriate, color coded, male connector
attached and the female connector (not shown) furnished with a cable clamp. Maximum
service temperature of connectors is 450 degrees Fahrenheit. If other connectors are
required, contact the factory.
NOTES: • High temperature (800 degrees Fahrenheit) standard
connectors and miniature plugs & jacks also available
• Duplex and multiple units also
available, contact factory. • PFA Teflon® encapsulation - good to 450°F, can be
added to any probe.

Exposed Junction Grounded Junction Ungrounded Junction

Thermocouple calibration type N is available in all sizes.


304 Stainless Steel Sheath - Specifications Inconel 600 Sheath - Specifications

Sheath Exposed Grounded Ungrounded Sheath Exposed Grounded Ungrounded


Type Diameter Junction Junction Junction Type Diameter Junction Junction Junction
(in.) Part No. Part No. Part No. (in.) Part No. Part No. Part No.
J 0.062 A8A-1 A8A-5 A8A-9 J 0.062 A8A-49 A8A-53 A8A-57
J 0.125 A8A-2 A8A-6 A8A-10 J 0.125 A8A-50 A8A-54 A8A-58
J 0.187 A8A-3 A8A-7 A8A-11 J 0.187 A8A-51 A8A-55 A8A-59
J 0.250 A8A-4 A8A-8 A8A-12 J 0.250 A8A-52 A8A-56 A8A-60
K 0.062 A8A-13 A8A-17 A8A-21 K 0.062 A8A-61 A8A-65 A8A-69
K 0.125 A8A-14 A8A-18 A8A-22 K 0.125 A8A-62 A8A-66 A8A-70
K 0.187 A8A-15 A8A-19 A8A-23 K 0.187 A8A-63 A8A-67 A8A-71
K 0.250 A8A-16 A8A-20 A8A-24 K 0.250 A8A-64 A8A-68 A8A-72
E 0.062 A8A-25 A8A-29 A8A-33 E 0.062 A8A-73 A8A-77 A8A-81
E 0.125 A8A-26 A8A-30 A8A-34 E 0.125 A8A-74 A8A-78 A8A-82
E 0.187 A8A-27 A8A-31 A8A-35 E 0.187 A8A-75 A8A-79 A8A-83
E 0.250 A8A-28 A8A-32 A8A-36 E 0.250 A8A-76 A8A-80 A8A-84
T 0.062 A8A-37 A8A-41 A8A-45 T 0.062 A8A-85 A8A-89 A8A-93
T 0.125 A8A-38 A8A-42 A8A-46 T 0.125 A8A-86 A8A-90 A8A-94
T 0.187 A8A-39 A8A-43 A8A-47 T 0.187 A8A-87 A8A-91 A8A-95
T 0.250 A8A-40 A8A-44 A8A-48 T 0.250 A8A-88 A8A-92 A8A-96

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 11


Thermocouple Assemblies
with Flexible Fiberglass Insulated Leads
A8B Series

These thermocouples are available with either stainless steel or inconel sheaths. Fitted
with a transition from the sheath to 36 inches of fiberglass insulated (insulation code 828)
flexible leads. Available in thermocouple types E, J, K, and T as a standard assembly. Other
thermocouple calibrations as well as various lead wire insulation materials are available
upon request.

Maximum service temperature of the transition adaptor is 400 degrees Fahrenheit.


Maximum use temperature of the thermocouple is determined by considering the sheath
material being used and the thermocouple calibration. Standard units are 12 inches long,
units can be made as short as 1-1/2 inches long without any special consideration.
NOTES: • For high temperature (800 degrees
Fahrenheit) connectors and miniature
• When ordering, specify Part No. and Length “L” plugs and jacks see our F2 and F3
Example: A8B-1-12 Series.
• PFA Teflon® encapsulation - good to 450°F, can • All assemblies use magnesia (Mg0)
be added to any probe. internal insulation. Contact factory if
• Duplex and multiple units also available. other types of insulation are required.

Thermocouple calibration type N is available in all sizes.


304 Stainless Steel Sheath - Specifications Inconel 600 Sheath - Specifications

Sheath Exposed Grounded Ungrounded Sheath Exposed Grounded Ungrounded


Type Diameter Junction Junction Junction Type Diameter Junction Junction Junction
(in.) Part No. Part No. Part No. (in.) Part No. Part No. Part No.
J 0.062 A8B-1 A8B-5 A8B-9 J 0.062 A8B-49 A8B-53 A8B-57
J 0.125 A8B-2 A8B-6 A8B-10 J 0.125 A8B-50 A8B-54 A8B-58
J 0.187 A8B-3 A8B-7 A8B-11 J 0.187 A8B-51 A8B-55 A8B-59
J 0.250 A8B-4 A8B-8 A8B-12 J 0.250 A8B-52 A8B-56 A8B-60
K 0.062 A8B-13 A8B-17 A8B-21 K 0.062 A8B-61 A8B-65 A8B-69
K 0.125 A8B-14 A8B-18 A8B-22 K 0.125 A8B-62 A8B-66 A8B-70
K 0.187 A8B-15 A8B-19 A8B-23 K 0.187 A8B-63 A8B-67 A8B-71
K 0.250 A8B-16 A8B-20 A8B-24 K 0.250 A8B-64 A8B-68 A8B-72
E 0.062 A8B-25 A8B-29 A8B-33 E 0.062 A8B-73 A8B-77 A8B-81
E 0.125 A8B-26 A8B-30 A8B-34 E 0.125 A8B-74 A8B-78 A8B-82
E 0.187 A8B-27 A8B-31 A8B-35 E 0.187 A8B-75 A8B-79 A8B-83
E 0.250 A8B-28 A8B-32 A8B-36 E 0.250 A8B-76 A8B-80 A8B-84
T 0.062 A8B-37 A8B-41 A8B-45 T 0.062 A8B-85 A8B-89 A8B-93
T 0.125 A8B-38 A8B-42 A8B-46 T 0.125 A8B-86 A8B-90 A8B-94
T 0.187 A8B-39 A8B-43 A8B-47 T 0.187 A8B-87 A8B-91 A8B-95
T 0.250 A8B-40 A8B-44 A8B-48 T 0.250 A8B-88 A8B-92 A8B-96

12 Tel: 800.786.4669 | Int’l: 001.508.872.4811


General Purpose Thermocouple Probes
with Armored Flexible Cable & Fiberglass Insulated Lead Wire
A8C Series
A

These thermocouples are available with either stainless steel or inconel sheaths. Fitted
with a transition from the sheath to 36 inches of fiberglass insulated flexible leads which
are enclosed within stainless steel armor for use in rugged applications. These units are
available in thermocouple types E, J, K, and T as a standard assembly. Other thermocouple
calibrations as well as various lead wire insulation materials are available upon request.

Maximum service temperature of the transition adaptor 400 degrees Fahrenheit. Maximum
use temperature of the thermocouple is determined by considering the sheath material
being used and the thermocouple calibration. Standard units are 12 inches long, units can
be made as short as 1-1/2 inches long without any special consideration.
NOTES: • Duplex units are available on units larger than
0.062” contact factory with your particular
• Various adjustable compression fittings requirement.
and mounting bushings are available for
these units. • Lead lengths other than 36 inches, and lead wire
insulations other than fiberglass are available.
• Both standard size and miniature plugs
and jacks are also available. • PFA Teflon® encapsulation - good to 450°F, can
be added to any probe.

Thermocouple calibration type N is available in all sizes.


304 Stainless Steel Sheath - Specifications Inconel 600 Sheath - Specifications

Sheath Exposed Grounded Ungrounded Exposed Grounded Ungrounded


Junction Junction Junction Sheath Junction Junction Junction
Type Diameter Type
Diameter
(in.) Part No. Part No. Part No. Part No. Part No. Part No.
J 0.062 A8C-1 A8C-5 A8C-9 J 0.062 A8C-49 A8C-53 A8C-57
J 0.125 A8C-2 A8C-6 A8C-10 J 0.125 A8C-50 A8C-54 A8C-58
J 0.187 A8C-3 A8C-7 A8C-11 J 0.187 A8C-51 A8C-55 A8C-59
J 0.250 A8C-4 A8C-8 A8C-12 J 0.250 A8C-52 A8C-56 A8C-60
K 0.062 A8C-13 A8C-17 A8C-21 K 0.062 A8C-61 A8C-65 A8C-69
K 0.125 A8C-14 A8C-18 A8C-22 K 0.125 A8C-62 A8C-66 A8C-70
K 0.187 A8C-15 A8C-19 A8C-23 K 0.187 A8C-63 A8C-67 A8C-71
K 0.250 A8C-16 A8C-20 A8C-24 K 0.250 A8C-64 A8C-68 A8C-72
E 0.062 A8C-25 A8C-29 A8C-33 E 0.062 A8C-73 A8C-77 A8C-81
E 0.125 A8C-26 A8C-30 A8C-34 E 0.125 A8C-74 A8C-78 A8C-82
E 0.187 A8C-27 A8C-31 A8C-35 E 0.187 A8C-75 A8C-79 A8C-83
E 0.250 A8C-28 A8C-32 A8C-36 E 0.250 A8C-76 A8C-80 A8C-84
T 0.062 A8C-37 A8C-41 A8C-45 T 0.062 A8C-85 A8C-89 A8C-93
T 0.125 A8C-38 A8C-42 A8C-46 T 0.125 A8C-86 A8C-90 A8C-94
T 0.187 A8C-39 A8C-43 A8C-47 T 0.187 A8C-87 A8C-91 A8C-95
T 0.250 A8C-40 A8C-44 A8C-48 T 0.250 A8C-88 A8C-92 A8C-96

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 13


General Purpose Thermocouple Probes
with Flexible Extensions (One-Piece Construction)
A8D Series

The construction of this thermocouple is a one piece design which does not utilize any
transition fitting. Advantages of this construction are no splices from thermocouple to lead
wire and no transition adaptors having a diameter greater than the thermocouple sheath.
Units can therefore be mounted from the inside out of a chamber, pushed into a drilled hole,
etc.
• Duplex units are available on various
NOTES: units, contact factory with your particular
requirement.
• Various adjustable compression fittings and
mounting bushings are available for these • Lead lengths other than 36 inches, and lead
units. wire insulations other than fiberglass are
available.
• Both standard size and miniature plugs and
jacks are also available. • PFA Teflon® encapsulation - good to 450°F,
can be added to any probe.

If you require that unit can be bent, contact factory for more information.

Thermocouple calibration type N is available in all sizes.


304 Stainless Steel Sheath - Specifications Inconel 600 Sheath - Specifications

Sheath Exposed Grounded Ungrounded Sheath Exposed Grounded Ungrounded


Type Diameter Junction Junction Junction Type Diameter Junction Junction Junction
(in.) Part No. Part No. Part No. (in.) Part No. Part No. Part No.
J 0.062 A8D-1 A8D-5 A8D-9 J 0.062 A8D-49 A8D-53 A8D-57
J 0.125 A8D-2 A8D-6 A8D-10 J 0.125 A8D-50 A8D-54 A8D-58
J 0.187 A8D-3 A8D-7 A8D-11 J 0.187 A8D-51 A8D-55 A8D-59
J 0.250 A8D-4 A8D-8 A8D-12 J 0.250 A8D-52 A8D-56 A8D-60
K 0.062 A8D-13 A8D-17 A8D-21 K 0.062 A8D-61 A8D-65 A8D-69
K 0.125 A8D-14 A8D-18 A8D-22 K 0.125 A8D-62 A8D-66 A8D-70
K 0.187 A8D-15 A8D-19 A8D-23 K 0.187 A8D-63 A8D-67 A8D-71
K 0.250 A8D-16 A8D-20 A8D-24 K 0.250 A8D-64 A8D-68 A8D-72
E 0.062 A8D-25 A8D-29 A8D-33 E 0.062 A8D-73 A8D-77 A8D-81
E 0.125 A8D-26 A8D-30 A8D-34 E 0.125 A8D-74 A8D-78 A8D-82
E 0.187 A8D-27 A8D-31 A8D-35 E 0.187 A8D-75 A8D-79 A8D-83
E 0.250 A8D-28 A8D-32 A8D-36 E 0.250 A8D-76 A8D-80 A8D-84
T 0.062 A8D-37 A8D-41 A8D-45 T 0.062 A8D-85 A8D-89 A8D-93
T 0.125 A8D-38 A8D-42 A8D-46 T 0.125 A8D-86 A8D-90 A8D-94
T 0.187 A8D-39 A8D-43 A8D-47 T 0.187 A8D-87 A8D-91 A8D-95
T 0.250 A8D-40 A8D-44 A8D-48 T 0.250 A8D-88 A8D-92 A8D-96

14 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Thermocouple Assemblies
with General Purpose Heads
A8E Series
The standard probe contains an ungrounded thermocouple A
assembly with a General Purpose aluminum head. A terminal
block is mounted on the interior of the GP Head. The GP Head
has 1/2” NPT mounting threads & conduit outlet. This assembly
is available with a 4” long stainless steel support tube for use
with adjustable mounting fittings. The support tube is 1/8” larger
in diameter than the sheath diameter.
NOTES:
• Duplex units are available on units larger than 0.062” contact
factory with your particular requirement.
• Various thermowells are available for use with these sensors.
• When ordering a unit with the optional stainless steel support
tube, add suffix (ST) to part number.
• PFA Teflon® encapsulation - good to 450°F, can be added to
any probe.

Thermocouple calibration
type N is available in all sizes.

Specifications
Sheath Sheath
Part No.
Diameter (in.) Material
A8E-1 0.062 SS 304
A8E-2 0.125 SS 304
A8E-3 0.187 SS 304
A8E-4 0.250 SS 304
A8E-5 0.062 Inconel 600
A8E-6 0.125 Inconel 600
A8E-7 0.187 Inconel 600
A8E-8 0.250 Inconel 600
A8E-9 0.187 Quartz
A8E-10 0.250 Quartz
A8E-11 0.375 Quartz
A8E-12 0.187 Al2O3 - 99.5%
A8E-13 0.250 Al2O3 - 99.5%
A8E-14 0.375 Al2O3 - 99.5%

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 15


Thermocouple Assemblies
with Miniature Plugs Attached
A8F Series

This Miniature Thermocouple Probe-Assembly comes completely assembled with a


miniature color-coded thermoset plastic plug with flat polarized prongs. A female jack is
included with each unit. Both stainless steel and inconel sheaths are available. The standard
sheath has a length of six inches, please specify your length if other than six inches.
NOTES: • High temperature (800 degrees Fahrenheit)
connectors and miniature plugs and jacks
• Various compression fittings and mounting also available (contact factory for your
bushings are available. requirement).
• Duplex and multiple units are available. • PFA Teflon® encapsulation - good to 450°F,
can be added to any probe.

Exposed Junction Grounded Junction Ungrounded Junction

Thermocouple calibration type N is available in all sizes.


304 Stainless Steel Sheath - Specifications Inconel 600 Sheath - Specifications

Sheath Exposed Grounded Ungrounded Sheath Exposed Grounded Ungrounded


Type Diameter Junction Junction Junction Type Diameter Junction Junction Junction
(in.) Part No. Part No. Part No. (in.) Part No. Part No. Part No.
J 0.040 A8F-1 A8F-4 A8F-7 J 0.040 A8F-37 A8F-40 A8F-43
J 0.062 A8F-2 A8F-5 A8F-8 J 0.062 A8F-38 A8F-41 A8F-44
J 0.125 A8F-3 A8F-6 A8F-9 J 0.125 A8F-39 A8F-42 A8F-45
K 0.040 A8F-10 A8F-13 A8F-16 K 0.040 A8F-46 A8F-49 A8F-52
K 0.062 A8F-11 A8F-14 A8F-17 K 0.062 A8F-47 A8F-50 A8F-53
K 0.125 A8F-12 A8F-15 A8F-18 K 0.125 A8F-48 A8F-51 A8F-54
E 0.040 A8F-19 A8F-22 A8F-25 E 0.040 A8F-55 A8F-58 A8F-61
E 0.062 A8F-20 A8F-23 A8F-26 E 0.062 A8F-56 A8F-59 A8F-62
E 0.125 A8F-21 A8F-24 A8F-27 E 0.125 A8F-57 A8F-60 A8F-63
T 0.040 A8F-28 A8F-31 A8F-34 T 0.040 A8F-64 A8F-67 A8F-70
T 0.062 A8F-29 A8F-32 A8F-35 T 0.062 A8F-65 A8F-68 A8F-71
T 0.125 A8F-30 A8F-33 A8F-36 T 0.125 A8F-66 A8F-69 A8F-72

16 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Teflon Tubing
and Encapsulation
A8G Series

We offer PFA Teflon® expanded tubing with one end closed


A
for heat shrinking onto probes from 1/16 inch diameter to 1/4
inch diameter and lengths of 60 inches. This PFA tubing is rated
at 260 degrees Celsius (450 degrees Fahrenheit) maximum
continuous service temperature. These tubes can be shrunk
onto the thermocouple or RTD probe with a hot air gun at
300 degrees Fahrenheit. The PFA Teflon® coated probes are
ideal for use in caustic or corrosive chemical solutions. The
temperature of sulfuric, hydrochloric, nitric, and chromic acids
can be measured at temperatures up to 450 degrees Fahrenheit.
Thermocouple and RTD probes can also be encapsulated with
PFA Teflon® at time of manufacture at a small surcharge.
NOTES: • When ordering encapsulated probes,
specify the Part No. of the probe and the
• When ordering closed end tubing, specify Part No. of the encapsulation.
the Part No. and Quantity.
• PFA Teflon® encapsulation - good to 450°F,
• Probes are sold separately can be added to any probe.

Teflon PFA Sealed Tubing - Specifications

6” 12” 18” 24” 36” 48” 60”


Diameter/Length
0.063” A8G-1 A8G-5 A8G-9 A8G-13 A8G-17 A8G-21 A8G-25
0.125” A8G-2 A8G-6 A8G-10 A8G-14 A8G-18 A8G-22 A8G-26
0.188” A8G-3 A8G-7 A8G-11 A8G-15 A8G-19 A8G-23 A8G-27
0.250” A8G-4 A8G-8 A8G-12 A8G-16 A8G-20 A8G-24 A8G-28

Teflon PFA Encapsulation - Specifications


Probe
6” 12” 18” 24” 36” 48” 60”
Diameter/Length
0.063” A8G-29 A8G-33 A8G-37 A8G-41 A8G-45 A8G-49 A8G-53
0.125” A8G-30 A8G-34 A8G-38 A8G-42 A8G-46 A8G-50 A8G-54
0.188” A8G-31 A8G-35 A8G-39 A8G-43 A8G-47 A8G-51 A8G-55
0.250” A8G-32 A8G-36 A8G-40 A8G-44 A8G-48 A8G-52 A8G-56

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 17


Thermocouple Extension Assemblies
A8H Series

Our Thermocouple Extension Assemblies feature #20 gage fiberglass insulated wire
with flexible stainless steel armor. Solid #20 gage thermocouple grade wires are used for
thermocouple types E, J, K, and T. Extension grade #20 gage solid wires are used for types
Rx, Sx, Bx, and Cx thermocouples. Other insulation types are available, contact factory with
your specify requirement (standard length “Y” is 36 inches ±1 inch).
Specify Part No. and length (Example: A8H-1-36 specifies type J, and 36 inches long).
Thermocouple calibration type N is available in all sizes.
Specifications
Dimension Drawings
Part No. Type
Single A8H-1 J
A8H-2 K
A8H-3 E
A8H-4 T
A8H-5 R/S/B
A8H-6 C
Single A8H-7 J
A8H-8 K
A8H-9 E
A8H-10 T
A8H-11 R/S/B
A8H-12 C

Single A8H-13 J
A8H-14 K
A8H-15 E
A8H-16 T
A8H-17 R/S/B
A8H-18 C
Duplex A8H-19 J
A8H-20 K
A8H-21 E
A8H-22 T
A8H-23 R/S/B
A8H-24 C

Duplex A8H-25 J
A8H-26 K
A8H-27 E
A8H-28 T
A8H-29 R/S/B
A8H-30 C

Duplex A8H-31 J
A8H-32 K
A8H-33 E
A8H-34 T
A8H-35 R/S/B
A8H-36 C

18 Tel: 800.786.4669 | Int’l: 001.508.872.4811


RTD Cable Assemblies
A8H-RTD Series

Our RTD cable assemblies feature either fiberglass (FIB) insulation rated at 900 degrees
Fahrenheit or teflon (TEF) insulation rated at 400 degrees Fahrenheit. Available in two, three,
or four conductors. The standard plugs and jacks are rated to a continuous 400 degrees
Fahrenheit.

NOTES:
• For (HT - high temperature) plugs and jacks • Custom design units are available; contact
rated to 800 degrees Fahrenheit, specify by the factory with your specific requirement.
adding the suffix HT.
• When ordering, specify part number and
• Standard “Y” length is 36 inches ±1 inch; if length. Example: A8H-RTD-31-72 specifies
your length requirement is different, please a 3 wire fiberglass insulated assembly with
specify. The pigtails use teflon shrink standard plug and jack, 72 inches long.
tubing.

Specifications
Number
Dimension Drawings Part No. Type
of Wires

A8H-RTD-10 2 FIB
A8H-RTD-11 3 FIB
A8H-RTD-12 4 FIB

A8H-RTD-13 2 TEF
A8H-RTD-14 3 TEF
A8H-RTD-15 4 TEF

A8H-RTD-20 2 FIB
A8H-RTD-21 3 FIB
A8H-RTD-22 4 FIB

A8H-RTD-23 2 TEF
A8H-RTD-24 3 TEF
A8H-RTD-25 4 TEF

A8H-RTD-30 2 FIB
A8H-RTD-31 3 FIB
A8H-RTD-32 4 FIB

A8H-RTD-33 2 TEF
A8H-RTD-34 3 TEF
A8H-RTD-35 4 TEF

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 19


Thermocouple Terminations
A9 Series

Illustrations Specifications

Plain End
Style 1
One Inch Bare Leads

Flexible fiberglass insulated leads swaged


into sheath. One-piece wire construction;
Style 2
no splices (three foot flexible leads
are standard).

Standard 2-prong connector attached to


Style 4
sheath or flex leads with appropriate adaptor.

Heavy-walled support tube 1/8 inch larger


than sheath, for use with mounting bushings.
Style 5
Standard size plug mounted on tube
is included.

General Purpose Head with 1/2 inch NPT


conduit outlet. Includes terminal block
Style 6 on interior of GP connector. This can be
combined with a Cold Leg
Extension Assembly.

Transition splice with spring relief. Three feet


Style 7
of fiberglass insulated leads attached.

Miniature connector with two flat prongs,


attached to sheath or flex leads with
Style 8
appropriate adaptor. Maximum probe
diameter 3/16 inch.

Style 9 #10 spade lugs on end of three inch pigtail

Transition splice with spring relief plus 12


Style 10 inches of coiled PVC insulated extension
cable, will stretch to 48 inches repeatedly.

Heavy Duty Cold Leg Extension


In addition to straight assembly units; we offer a right
angle type cold leg extension. Using a general purpose
connector head to make the bend instead of a pipe
elbow. Allowing for easier maintenance, servicing and
replacement components; thus reducing your overall
costs. Consisting of a carbon steel pipe of specified
length with 1/2” NPT threaded ends.

Many other styles available - contact factory

20 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Adjustable Compression Fittings
A10 Series

We offer two styles of adjustable compression fittings for


use in mounting thermocouples into thick or thin walls. One
A
style uses a standard NPT pipe thread while the other uses a
straight thread with O-ring seal. Both are typically available
from stock in 316 stainless steel (brass upon request).

Pipe Thread Fitting Style - Specifications Both styles are available for probe
Tube Male diameters from 1/16” to 1.0” OD.
Part No. OD Pipe Size A B C (other sizes upon request). The O-ring
T P
style is also ideal for use in thin-wall
A10-1 1/16 1/16 15/16 3/8 7/16
A10-2 1/16 1/8 1 3/8 7/16 applications, glass containers, jar lids,
A10-3 1/8 1/8 1-3/16 3/8 5/8 etc. Simply put a jam nut on other
A10-4 3/16 1/8 1-15/64 3/8 21/32
A10-4A 3/16 1/4 1-5/16 9/16 23/32 side of container lid.
A10-5 1/4 1/8 1-5/16 3/8 23/32
A10-6 1/4 1/4 1-1/2 9/16 23/32 NOTES:
A10-7 1/4 3/8 1-17/32 9/16 23/32 • If a (BR - brass) adjustable
A10-8 1/4 1/2 1-3/4 3/4 23/32 compression fitting is desired, list
A10-9 5/16 1/8 1-23/64 3/8 3/4 the Part No. and BR.
A10-10 5/16 1/4 1-35/64 9/16 3/4 Example: A10-1-BR
A10-11 3/8 3/4 1-13/16 3/4 3/4
A10-12 3/8 1/4 1-19/32 9/16 25/32 • If a (SS - stainless steel) adjustable
A10-13 3/8 3/8 1-19/32 9/16 25/32 compression fitting is desired, add
A10-14 3/8 1/2 1-13/16 3/4 25/32 the suffix SS to the Part No.
A10-15 1/2 1/4 1-23/32 9/16 7/8 Example: A10-1-SS
A10-16 1/2 3/8 1-23/32 9/16 7/8
A10-17 1/2 1/2 1-29/32 3/4 7/8
A10-18 1/2 3/4 1-15/16 3/4 7/8
A10-19 5/8 3/8 1-3/4 9/16 7/8
A10-20 5/8 1/4 1-15/16 3/4 7/8
A10-22 3/4 3/4 2 3/4 7/8
A10-23 7/8 3/4 2 3/4 7/8
A10-25 1 1 2-7/16 15/16 1-1/32

Minor length variations should be expected

O-Ring Style - Specifications


Tube Male
Part No.
OD Pipe Size A B C
(Brass)
T S
A10-26 1/16 5/16-24 1-1/16 11/32 7/16
A10-27 1/8 5/16-24 1-5/16 11/32 5/8
A10-28 3/16 3/8-24 1-3/8 3/8 21/32
A10-29 1/4 7/16-20 1-17/32 13/32 23/32
A10-30 5/16 1/2-20 1-5/16 7/16 3/4
A10-31 3/8 9/16-18 1-11/16 15/32 25/32
A10-32 1/2 3/4-16 1-13/16 15/32 7/8
A10-33 5/8 7/8-14 1-29/32 15/32 7/8
A10-34 3/4 1-1/16-12 2-1/16 9/16 7/8
A10-35 7/8 1-1/16-12 2-1/16 9/16 7/8
A10-36 1 1-5/16-12 2-9/32 9/16 1-1/32

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 21


High Temperature Thermocouple Probes
for Vacuum, Carburizing, Annealing, Hardening, and Sintering Applications
A11 Information

Our line of High Temperature Thermocouples are specially designed for temperatures
ranging from 1,000 degrees Fahrenheit to 4,235 degrees Fahrenheit. Sheath materials
available from stock include tantalum, molybdenum, zirconia, alumina, and quartz. Chief
characteristics of the sheath materials are summarized.

TANTALUM (Ta):
Melting point of 5,430 degrees Fahrenheit; the most corrosive resistant of the refractory metals. Corrosion
resistant to most chemicals up to 3,000 degrees Fahrenheit. Good in reducing or neutral atmospheres
at elevated temperatures. Poor in oxidizing atmospheres and excellent for thermal cycling applications.

MOLYBDENUM (Mo):
Excellent mechanical properties at elevated temperatures. Melting point at 4,750 degrees Fahrenheit;
excellent in reducing or neutral atmospheres. Having low thermal-neutron capture cross-section and
excellent thermal shock resistance. Poor in oxidizing atmospheres but excellent for thermal cycling
applications.

ALUMINA (Al2O3):
This high purity sintered aluminum oxide (99.5% AI2O3, dense) has a melting point of 3,686 degrees
Fahrenheit (2,030 degrees Celsius) and an upper working service temperature of 3,482 degrees Fahrenheit
(1,900 degrees Celsius). It can be used in oxidizing, reducing, or high vacuum applications. Not
recommended for use in high vacuum environments in the presence of graphite at temperatures exceeding
2,372 degrees Fahrenheit (1,300 degrees Celsius). Alumina (AI2O3) has high thermal conductivity and
therefore fairly good resistance to thermal shock. Having excellent resistance to chemical attack but poor
for thermal cycling applications.

ZIRCONIA (ZRO2):
Zirconium oxide is fully stabilized with exceptional refractory properties, which include the highest
melting point and lowest thermal conductivity of any refractory. It is not wetted by most molten metals,
is generally inert to oxidizing and reducing atmospheres, and resists most chemical reactions. Usable to
4400°F. It is impervious (0% water absorption). Poor for thermal cycling applications.

FUSED QUARTZ:
Fused silica consists of 99,9%SiOi; most acids, metals, chlorine, and bromine are reactive with fused
silica at ordinary temperatures. Slightly attacked by alkaline solutions, the reaction rate increasing with
temperature and concentration of solution. Fused silica has an extremely low coefficient of thermal
expansion, 0.55 x 10-6 cm/cm/°F (0-572 degrees Fahrenheit). This is 1/34th that of copper, 1/17th of
platinum and 1/9th of tungsten. This low expansion produces a high thermal shock resistance, heated to
2700’’F, and immersed into ice water without cracking. Good for oxidizing, inert or neutral atmospheres
to 3,050 degrees Fahrenheit. Excellent for thermal shock applications; devitrifies rapidly at temperatures
above 1,800 degree Fahrenheit causing microscopic surface cracking (hazy film) upon cooling.

Applications:
Oxidizing, Vacuum, Reducing and Inert Gas Furnaces, Gas Burners, Ovens, Nuclear Power
Generating Plants, Exhaust Gases, Wind Tunnels, Pollution Control, and High Temperature
Process Control Applications.

22 Tel: 800.786.4669 | Int’l: 001.508.872.4811


High Temperature Thermocouple Probes
A11A Series

Our standard High Temperature Thermocouple Probe consists of an ungrounded thermal


junction within a closed end sheath. It also includes a set of standard matching plug and jack
connectors. With male connector attached and the female connector (not shown) furnished
with a cable clamp. Maximum service temperature of connector is 450 degrees Fahrenheit.

This High Temperature Thermocouple Probe is also available with an optional, four inch
long support tube attached to the connector end. The purpose of the support tube is to
eliminate any damage to the refractory sheath that may be caused by the mounting bushing.
The support tube is 1/8 inch larger in diameter than the thermocouple sheath. If a support
tube is desired, insert the suffix (ST) onto the part number.
NOTES:
• These thermocouples all use a #30 gage • High temperature (800 degrees Fahrenheit)
(0.010”) size elements. connectors also available (contact factory
for your requirement).
• Various adjustable compression fittings and
mounting bushings are available. • When ordering, specify Part No.
thermocouple type and length.
• Duplex and multiple units are also available. Example: A11A-1-12-R

Specifications
Sheath Sheath
Part No.
Diameter Material
A11A-1 0.125
A11A-2 0.187 Molybdenum All A11A Series Probes
A11A-3 0.250
A11A-4 0.063
A11A-5 0.125 Ungrounded Junction
Tantalum
A11A-6 0.187
A11A-7 0.250
A11A-10 0.187
A11A-11 0.250 Alumina
A11A-12 0.375
A11A-14 0.250
Zirconia
A11A-15 0.375
A11A-16 0.187
A11A-17 0.250 Quartz
A11A-18 0.375

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 23


High Temperature Thermocouple Probes
A11B Series

The standard probe contains an ungrounded thermocouple


assembly with a general purpose aluminum head. A terminal
block is mounted in the interior of the GP head. The GP head
has a 1/2 inch NPT conduit outlet.

This thermocouple assembly is also available with a four


inch long stainless steel support tube for use with adjustable
mounting fittings. The support tube is 1/8 inch larger in diameter
than the sheath diameter. When ordering this unit, add suffix
(ST) to Part No.

NOTES:
• These thermocouples use #30 gage (0.010”) size elements.
• Duplex and multiple units also available (contact factory)
• When ordering, specify Part No., Length “L” and thermocouple
type. Example: A11B-1-12-R

Various adjustable compression fittings


and mounting bushings are available.

Specifications
Sheath Sheath
Part No.
Diameter Material
A11B-1 0.125
A11B-2 0.187 Molybdenum
A11B-3 0.250
A11B-5 0.125
A11B-6 0.187 Tantalum
A11B-7 0.250
A11B-9 0.187
A11B-10 0.250 Alumina
A11B-11 0.375
A11B-13 0.250
Zirconia
A11B-14 0.375

24 Tel: 800.786.4669 | Int’l: 001.508.872.4811


High Temperature Thermocouple Probes
A11C Series

This probe contains an ungrounded thermocouple assembly with a transition junction, a


stress relief spring, and 36 inches of fiberglass insulated #20 gage (0.032’) extension leads.
These extension leads are shielded with a stainless steel over braid. This thermocouple
is also available with a four inch long support tube attached to the transition end. The
purpose of the support tube is to eliminate any damage to the refractory sheath that may be
caused by the mounting bushing. That support tube is 1/8 inch larger in diameter than the
thermocouple sheath. If a support tube is desired, insert the suffix (ST) onto the Part No.

NOTES:
• These thermocouples use #30 gage • Various adjustable compression fittings and
(0.010”) size elements. mounting bushings are available.
• These units are available with a standard • Duplex and multiple units also available
miniature or high temperature connector (contact factory)
attached (contact factory).
• When ordering, specify Part No., Length “L”
• Various adjustable compression fittings and and thermocouple type.
mounting bushings are available. Example: A11B-1-12-R

Specifications
Part No. Sheath Diameter Sheath Material
A11C-1 0.125
A11C-2 0.187 Molybdenum
A11C-3 0.250
A11C-5 0.125
A11C-6 0.187 Tantalum
A11C-7 0.250
A11C-9 0.187
A11C-10 0.250 Alumina
A11C-11 0.375
A11C-13 0.250
Zirconia
A11C-14 0.375

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 25


Heavy Duty High Temperature Thermocouple Probes
A12 Series

This high temperature thermocouple probe consists of an ungrounded thermal junction


within a closed end sheath. It also includes a set of standard matching plug and jack
connectors with the male connector attached and the female connector (not shown) furnished
with a cable clamp. Maximum service temperature of connector is 450 degrees Fahrenheit.

This high temperature thermocouple probe is also available with a thick wall, four inch long
support tube attached to the connector end. The purpose of the support tube is to eliminate
any damage to the refractory sheath that may be caused by the mounting bushing. The
support tube is an 1/8 inch larger in diameter than the thermocouple sheath. If a support
tube is desired, insert the suffix (ST) onto the Part No.
NOTES:
• Duplex and multiple units also available
• These thermocouples use #24 gage (contact factory)
(0.020”) size elements.
• High temperature (800 degrees Fahrenheit)
• Various adjustable compression fittings and connectors and miniature plugs & jacks also
mounting bushings are available. available.

Specifications
Sheath Sheath
Part No.
Diameter Material
A12-1 0.125
A12-2 0.187 Molybdenum All A12 Series Probes
A12-3 0.250
A12-5 0.125
A12-6 0.187 Tantalum Ungrounded Junction
A12-7 0.250
A12-10 0.187
A12-11 0.250 Alumina
A12-12 0.375
A12-14 0.250
Zirconia
A12-15 0.375
A12-16 0.187
A12-17 0.250 Quartz
A12-18 0.375

26 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Heavy Duty High Temperature Thermocouple Probes
A12A Series

This standard probe contains an ungrounded thermocouple


assembly with a General Purpose Aluminum Head. A terminal
A
block is mounted in the interior of the GP Head. The GP Head
has a 1/2 inch NPT conduit outlet.

This thermocouple assembly is also available with a four


inch long stainless steel support tube for use with adjustable
mounting fittings. The support tube is an 1/8 inch larger in
diameter than the sheath diameter. When ordering this unit,
add suffix (ST) to Part No.

NOTES:
• These thermocouples use #24 gage (0.020”) size elements.
• Duplex and multiple units also available (contact factory)
• When ordering, specify Part No. Length “L” and thermocouple
type.

Various adjustable compression fittings


and mounting bushings are available.

Specifications
Sheath Sheath
Part No.
Diameter Material
A12A-1 0.125
A12A-2 0.187 Molybdenum
A12A-3 0.250
A12A-5 0.125
A12A-6 0.187 Tantalum
A12A-7 0.250
A12A-9 0.187
A12A-10 0.250 Alumina
A12A-11 0.375
A12A-13 0.250
Zirconia
A12A-14 0.375

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 27


Heavy Duty High Temperature Thermocouple Probes
A12B Series

This probe contains an ungrounded thermocouple assembly with a transition junction, a


stress relief spring, and 36 inches of fiberglass insulated #20 gage (0.032’) extension leads.
The extension leads are shielded with a stainless steel over braid.

This thermocouple is also available with a thick wall, four inch long support tube attached
to the transition end. The purpose of the support tube is to eliminate any damage to the
refractory sheath that may be caused by the mounting bushing. The support tube is an 1/8
inch larger in diameter than the thermocouple sheath. If a support tube is desired, insert the
suffix (ST) onto the Part No.

NOTES:
• These thermocouples use #24 gage
(0.020”) size elements. • Available with Standard, Miniature, or High
Temperature connectors attached (contact
• Various adjustable compression fittings and factory).
mounting bushings are available.
• When ordering, specify Part No. Length “L”
• Duplex and multiple units also available and thermocouple type.
(contact factory) Example: A12B-1-12-R

Specifications
Part No. Sheath Diameter Sheath Material
A12B-1 0.125
A12B-2 0.187 Molybdenum
A12B-3 0.250
A12B-5 0.125
A12B-6 0.187 Tantalum
A12B-7 0.250
A12B-9 0.187
A12B-10 0.250 Alumina
A12B-11 0.375
A12B-13 0.250
Zirconia
A12B-14 0.375

28 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Heavy Duty High Temperature Thermocouple Probes
for Pressures to 20,000 PSI
A12C-EQ Series
A

Many high pressure applications such as reaction chambers often times require temperature
monitoring and control at temperatures from 2,000 degrees Fahrenheit to over 3,000 degrees
Fahrenheit. Since refractory or ceramic sheathed thermocouples are used to monitor these
temperatures, the strength of these sheaths are not sufficient to withstand these external
pressures at these temperatures. In order to prevent the sheaths from collapsing, we have
drilled a small hole through the sheath at the sensing tip end, this feature allows the internal
pressure inside the sheath to equalize with the external pressure; thus, preventing the sheath
from collapsing. Also, we have built a gas-tight pressure seal into the thermowell; so that,
high pressure gases will not escape through the mineral oxide insulation.

This High Temperature Thermocouple uses either a molybdenum or tantalum sheath;


having a 1/16 inch hole drilled through the sheath near the junction end. Recommended use
in reducing or neutralizing atmosphere. Both are excellent in thermal cycling applications.
In oxidizing atmospheres either alumina or zirconia sheaths are recommended. Instead of
a 1/16 inch diameter hole, a small slot is machined through the sheath at the sensing end.
Alumina sheath is recommended to about 3,300 degrees Fahrenheit maximum, whereas
zirconia can be used to about 4,400 degrees Fahrenheit. Both of these sheaths must not be
subjected to temperature changes exceeding 200 degrees Fahrenheit per hour.
NOTES: • Use of a copper washer suggested to make
a seal, when installing
• All units come with a standard connector
attached (mating connector with cable • Standard unit has EQ hole at Hot end
clamps furnished). (EQH); EQ hole at Cold end (EQC) also
available.
• All platinum alloy thermocouples use high
purity alumina insulation. All tungsten alloy • When ordering specify Part No., Length, and
thermocouples use magnesia insulation. Thermocouple Type. Example: A12C-1-12-C

Specifications
Part No. A12C-1 A12C-2 A12C-3 A12C-4 A12C-5 A12C-6 A12C-7 A12C-8 A12C-9 A12C-10

Sheath
0.125 0.187 0.250 0.125 0.187 0.250 0.250 0.375 0.250 0.375
Diameter “A” (in.)

Sheath Material Molybdenum Tantalum Alumina Zirconia

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 29


High Temperature Probes
with Tungsten Coatings
A12D Series

Oftentimes a molybdenum sheathed thermocouple is used in a furnace with graphite liners


or heating elements. At temperatures above 1,600 degrees Celsius, any graphite present
emits dust molecules which attack the sheath and rapidly carburizes the sheath. This causes
the sheath to become crystallized and porous. The thermal elements lose their protection
and they also become crystallized and then break during cycling. Coating the protecting
sheath with a thick layer of tungsten minimizes this carburization process and extends the
life of the probes significantly. Field tests at 2,000 degrees Celsius using the coated probes
produced continuous temperature data up to 2 months (even during cycling) whereas the
uncoated probes failed within hours of reaching temperature. Longer lifetimes were also
experienced at temperatures below 2,000 degrees Celsius.

NOTES: Specifications
• These thermocouples use #24 gage Part No. Type
D1 (in.) D2 (in.)
(0.020”) size elements and molybdenum Approximate
sheaths. A12D-1 0.150 0.250
A12D-2 C 0.220 0.250
• Various adjustable compression fittings and A12D-3 0.284 0.375
mounting bushings are available.
A12D-4 0.150 0.250
• Duplex and multiple units also available A12D-5 S 0.220 0.250
(contact factory) A12D-6 0.284 0.375
• When ordering, specify Part No. Length “L” A12D-7 0.150 0.250
and thermocouple type. A12D-8 R 0.220 0.250
Example: A12D-1-17-C A12D-9 0.284 0.375

• Special designs available to suit your A12D-10 0.150 0.250


requirements. A12D-11 B 0.220 0.250
A12D-12 0.284 0.375

30 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Bare Wire Thermocouple Elements
A13 Series

Offering a wide variety of bare wire thermocouple elements in a large selection of wire sizes.
All base metal bare wire thermocouple types: E, J, K, N, and T come with a standard length
of 12 inch leads. Noble metal and refractory wire element types: B, D, C, S, and R come with
a standard element length of six inches. Other sizes and lengths are also available.
NOTES: • Elements with ceramic insulators are also
available (contact factory).
• All standard units have a twist and welded
junction, if requesting no twist use the suffix • All bare wire elements can be made to
NT. Example: A13-K-12-NT most lengths; contact the factory with your
requirement.

Specifications
12” Standard Lengths
Wire Dia.
Part No. Type
(in.)
A13-1 0.003
A13-2 0.005
A13-3 0.010
A13-4 0.015
A13-5 J 0.020
A13-6 0.032
A13-7 0.050
A13-8 0.064
Specifications A13-9 0.128
A13-10 0.003
6” Standard Lengths
A13-11 0.005
Wire Dia. A13-12 0.010
Part No. Type T
(in.) A13-13 0.015
A13-14 0.020
A13-31 0.005
A13-15 0.032
A13-32 0.010
S
A13-33 0.015 A13-16 0.003
A13-34 0.020 A13-17 0.005
A13-18 0.010
A13-35 0.005
A13-19 0.015
A13-36 0.010
R A13-20 K 0.020
A13-37 0.015
A13-21 0.032
A13-38 0.020
A13-22 0.050
A13-43 0.005 A13-23 0.064
A13-44 0.010 A13-24 0.128
D
A13-45 0.015
A13-25 0.003
A13-46 0.020
A13-26 0.005
A13-47 0.005 A13-27 0.010
E
A13-48 0.010 A13-28 0.015
C
A13-49 0.015 A13-29 0.020
A13-50 0.020 A13-30 0.032
A13-51 0.005 A13-60 0.020
A13-52 0.010 A13-61 0.032
B N
A13-53 0.015 A13-65 0.064
A13-54 0.020 A13-66 0.128

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 31


Thermocouple Insulators
A14 Series

We stock a broad line of insulators for use with all types and sizes of thermocouple wire.
Mullite insulators are recommended for use with bare metal thermocouple wire and element
types: E, J, K, N, and T up to 2,700 degrees Fahrenheit. High purity alumina oxide is
recommended for use with noble or refractory thermocouple wire and element types: B, C,
D, R, and S. Re-crystallized alumina is suitable up to 3,600 degrees Fahrenheit.
NOTES: • Example: A14-1-6 (is an 1/8 inch OD Mullite,
2 bore, 0.040 bore size, six inches long)
• Specify length in six inch increments.
• Special lengths are available

We do not recommend using Mullite (~70% Alumina / 30% Silica)


with either platinum or tungsten elements.

Specifications
Illustrations
Nominal OD Nominal ID
Style Part No. Material
(in.) (in.)
A14-1 1/8 0.040
A14-2 3/16 0.060
A14-3 Mullite 1/4 0.080
Double Bore A14-4 3/8 0.110
Round A14-5 1/2 0.150
A14-6 1/8 0.040
Oxide 99
A14-7 3/16 0.060
(High Purity Alumina)
A14-8 1/4 0.080

A14-9 1/8 x 0.090 0.030


A14-10 3/16 x 0.120 0.040
Double Bore
A14-11 Mullite 1/4 x 0.220 0.090
Oval
A14-12 3/8 x 0.220 0.090
A14-13 1/2 x 0.280 0.160

Four Bore A14-14 3/16 0.040


Mullite
Round A14-15 1/4 0.080

A14-19 1/4 0.110


Single Bore A14-20 Oxide 99 3/8 0.250
Round A14-21 (High Purity Alumina) 1/8 0.060
A14-22 3/16 0.080

32 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Industrial Base Metal Thermocouples
with Standard Size Connector Attached
A14A Series

Our Industrial Base Metal Thermocouples


A
offer a wide variety of ceramic insulated
thermocouples in a large selection of wire
sizes. All standard thermocouples (types E,
J, K & T) come with a standard length of 12
inch leads. Noble metal and refractory wire
elements (types B, C, D, R & S) come with a standard element length of six inches. Other
sizes and/or lengths are available upon request.

Mullite ceramic insulators are recommended for use with base metal thermocouple wire
and elements types E, J, K, N & T. High purity Alumina oxide is recommended for use
with noble or refractory thermocouple wire and elements, types B, C, D, R & S. Alumina is
suitable for up to 3,600 degrees Fahrenheit. Mullite (60% AL2O3 / 39% SiO2) is suitable to
2,700 degrees Fahrenheit.

Style 2 Shown for Clarity Style 1: Two-Hole Ceramic Insulated

NOTES:
• Length do not include approximately one Style 2: Duplex Ceramic Insulated
inch of bare wire at the terminating end.
• These units are also available with short ball
and socket insulators for units required to
bend, curve, etc.
• Contact factory with your specific
requirements. Typically a sketch is required
to quote these unique designs. Style 3: Ball & Socket Ceramic Insulated

• When ordering, specify series (A14A) and


Part No. by specifying each of the four
characteristics from columns A-B-C-D.
Example: A14A-2-14-K-24 (specifies a duplex Style 4: Angle
14 gage, type K, 24 inch long element)
• All units come standard with a twist and
welded junction. If you request no twist,
specify by adding the suffix NT.
Example: A14A-2-14-K-24-NT
Specifications
Wire
A14A A B C D Style
Gage/Diameter
Style Gauge Type Length 8 (0.128)
1 8 J (inches) 14 (0.064)
1
2 14 K 20 (0.032)
3 20 T 24 (0.020)
4 24 E 8 (0.128)
N 14 (0.064)
2
When ordering, specify Part No. and fill in the 4 letter blocks 20 (0.032)
Example: A14A-2-20-K-24 (specifies a Style 2 duplex thermocouple with 20 24 (0.020)
gauge Type K elements and length of 24 inches.

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 33


Flexible Thermocouples
and Extension Wire Assemblies
A14B Series

Thermocouples and extension leads with end preparations offer rapid solutions to many
temperature measurement applications at economical costs. All contain one pair of solid
conductors and are insulated with fiberglass over each leg and overall. Color codes and
premium grade elements are used throughout; thermocouple types include: E, J, K, N & T.

NOTES: A14B A B C D
• When ordering, specify Part No. and fill in Style Gauge Type Length
the four letter blocks. 1 8 J (inches)
• For stainless steel over braid add the suffix 2 14 K
SS to the Part No. 3 20 T
4 24 E
• Example: A14B-2-K-20-36 (specifies a style 2 N
thermocouple with spade lugs on cold end,
type K, gage #20 and an overall length of When ordering, specify Part No. and fill in the 4 letter blocks
Example: A14A-2-20-K-24 (specifies a Style 2 duplex thermocouple with 20
36 inches) gauge Type K elements and length of 24 inches.

Illustrations Specifications

Twist and welded hot junction with


Style 1
leads stripped at cold end

Twist and welded hot junction with lugs


Style 2
at cold end

Stripped one end


Style 3
Lugs on other end

Style 4 Stripped on both ends

Twist and welded hot junction


Style 5
with plug at cold end

Twist and welded hot junction


Style 6
with miniature plug at cold end

34 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Thermowell Assemblies
General Information
A17 Series
Thermowell Assemblies use female NPT threads for accepting male A
NPT pipe fittings. Because of normal tolerance and torque variations
during assembly, variations as much as 5/8 inch element lengths can
be encountered. When ordering replacement parts, care should be
taken to allow for normal variations in length. When ordering complete
assemblies, Nanmac will make the necessary adjustments to compensate
for these variations in lengths.

Since all metal thermowells have a female NPT connection thread and
all connection heads also have a female NPT thread; a nipple with male
NPT threads on both ends is required to attach the connection head
to the thermowell. A secondary purpose of the nipple is to physically
remove the connection head from a hot thermowell to a safe distance
so that an operator can safely open the connection head and make
necessary replacements or repairs.

The steel union is used to connect two nipples together. This


combination allows easy removal of the head and element from the well.

The outlet port of the


connection head in the Nanmac standard
connection head contains a 1/2 inch NPT female
thread. This is used to connect to your conduit pipe
containing the extension leads. Nipples and unions
should also be used here to facilitate connecting
and disconnecting the conduit pipe - they can also
be used to add extensions to your conduit pipe
where required.

Material:
Thermowells consist of drilled bar stock.
Standard well materials include brass (ASTM B-16),
carbon steel (C-1018), and stainless steel (A.I.S.I
B-16). Wells are also available in special grades
of stainless steel, chrome-molybdenum alloys,
silicon bronze, Hastelloy B and C, nickle, titanium,
inconel, and monel. The particular choice is usually
determined by the corrosive conditions under which
the thermowell must operate-commensurate with
the maximum service pressure and temperature.

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 35


Corrosive Service Guide to Materials

Corrodent Temperature Conc. Recommended Corrodent Temperature Conc. Recommended


°F % Material °F % Material
Acetic Acid 212 All Monel
Acetic Anhydride 300 - Nickel Hydrogen Chloride, Dry 500 - SS 304
Acetone 212 All SS 304 Hydrocyanic Acid 212 All SS 304
Acetylene 400 - SS 304 Hydrofluoric Acid 212 60% Monel
Alcohols 212 All SS 304 Hydrogen Fluoride, Dry 175 - Steel
Alum. (Potassium 300 All Hastelloy C Hydrofluogilicic Acid 212 40% Monel
or Sodium) - - - Hydrogen Peroxide 125 10-100% SS 304
Aluminum Chloride 212 All Hastelloy B Kerosene 300 All Steel
Aluminum Sulfate 212 All SS 316 Lacquers & Thinners 300 All SS 304
Ammonia, Dry 212 All SS 304, 316 Lactic Acid 300 All SS 316
Ammonia Hydroxide 212 All SS 304, 316 Lime 212 All SS 316
(Ammonia, Aqua) - - - Linseed Oil 75 - Steel
Ammonia Chloride 300 50% Monel Magnesium Chloride 212 50% Nickel
Ammonia Nitrate 300 All SS 304 Magnesium Hydroxide 75 All SS 304
Ammonia Sulfate 212 All SS 316 (or Oxide) - - -
Amyl Acetate 300 All SS 304 Magnesium Sulfate 212 40% SS 304
Aniline 75 - Monel Mercuric Chloride 75 10% Hastelloy C
Asphalt 250 - SS 304 Mercury 700 100% Steel
Atmosphere - - SS 304 Methylene Chloride 212 All SS 304
(Industrial and Marine) - - - Methyl Chloride, Dry 75 - Steel
Barium Compound See Calcium - - Milk, fresh or sour 180 - SS 304
Beer 70 - SS 304 Molasses See Glucose - -
Benzene (Benzol) 212 - Steel Natural Gas 70 - SS 304
Benzoic Acid 212 All SS 316 Nitric Acid 75 All SS 316
Bleaching Powder 70 15% Monel Nitric Acid 300 All SS 316
Borax 212 All Brass Oleic Acid See Fatty Acids All -
Bordeaux Mixture 200 SS 304 Oxalic Acid 212 All Monel
Boric Acid 400 All SS 316 Oxygen 75 All Steel
Bromine 125 Dry Monel Photographic 100 - SS 304
Butane 400 All Steel Bleaching - -
Butyl Alcohol See Alcohols - - Palmitic Acid See Fatty - -
Butyric Acid 212 - Hastelloy C - Acids All -
Calcium Bisulphite 75 All Hastelloy C Phosphoric Acid 212 All SS 316
Calcium Chloride 212 All Hastelloy C Phenol 212 - SS 316
Calcium Hydroxide 300 20% Hastelloy C Potassium Compounds See Sodium - -
Calcium Hypochlorite See Bleaching - - - Compound - Steel
- Powder - - Propane 300 100% SS 316
Carbolic Acid See Phenol - - Rosin 700 Monel
Carbon Dioxide, Dry 800 All Brass Sea Water 75 All SS 304
Carbonated Water 212 All SS 304 Soap & Detergent 212 20% SS 316
Carbonated Beverages 212 - SS 304 Sodium Bicarbonate 212 - -
Carbon Disulfide 200 - SS 304 Sodium Bisulphite 212 20% SS 304
Carbon Tetrachloride 125 All Monel Sodium Bisulphate 212 20% SS 304
Chlorine, Dry 100 - Monel Sodium Carbinate 212 40% SS 316
Chlorine, Moist 100 All Monel Sodium Chloride 300 30% Monel
Chloracetic Acid 212 All Monel Sodium Chromate 212 All SS 316
Chloroform, Dry 212 - Monel Salt or Brine See Sodium - -
Chromic Acid 300 All Hastelloy C - Chloride - -
Cider 300 All SS 304 Sodium Cyanide 212 All SS 304
Citric Acid 212 All Hastelloy C Sodium Hydroxide 212 30% SS 316
Copper (10) Chloride 212 All Hastelloy C Sodium Hypochlorite 75 10% Hastelloy C
Copper (10) Nitrate 300 All SS 316 Sodium Nitrate 212 40% SS 304
Copper (10) Sulfate 300 All SS 316 Sodium Nitrite 75 20% SS 316
Copper Plating 180 All SS 304 Sodium Phosphate 212 10% Steel
Solution (Cyanide) - - - Sodium Silicate 212 10% Steel
Copper Plating 75 - SS 304 Sodium Sulfide 212 30% SS 316
Solution (Acid) - - - Sodium Sulfite 212 10% SS 316
Corn Oil 200 - SS 304 Sodium Sulfate 212 30% SS 304
Creosote 200 All SS 304 Sodium Thiosulfate 212 All SS 304
Crude Oil 300 - Monel Steam - - SS 304
Ethyl Acetate See Lacquer - - Stearic Acid See Fatty - -
- Thinner - - - Acids - -
Ethyl Chloride, Dry 500 - Steel Sugar Solutions See Glucose - -
Ethanol See Alcohols - - Sulfur 500 - SS 304
Ethylene Glycol 212 All SS 316 Sulfur Chloride 75 Dry SS 316
(Uninhibited) - - - Sulfur Dioxide 500 Dry SS 316
Ethylene Oxide 75 - Steel Sulfur Trioxide 500 Dry SS 316
Fatty Acids 500 All SS 316 Sulfuric Acid 212 10% SS 316
Ferric Chloride 75 All Hastelloy C Sulfuric Acid 212 10-90% Hastelloy B
Ferric Sulfate 300 All SS 304 Sulfuric Acid 212 90-100% SS 316
Formaldehyde 212 40% SS 316 Sulfuric Acid, Fuming 175 - Hastelloy C
Formic Acid 300 All SS 316 Sulfurous Acid 75 20% SS 316
Freon 300 - Steel Titanium Tetrachloride 75 All SS 316
Fluorine, Anhydrous 100 - SS 304 Tannic Acid 75 40% Hastelloy B
Furfural 450 - SS 316 Toluene 75 - Steel
Gasoline 300 - Steel Trichloracetic Acid 75 All Hastelloy B
Glucose 300 - SS 304 Trichlorethylene 300 Dry Monel
Glue ph 6-8 300 All SS 304 Turpentine 75 - SS 316
Glycerine 212 All Brass Varnish 150 - Steel
Hydrobromic Acid 212 All Hastelloy C Zinc Chloride 212 All Hastelloy B
Hydrochloric Acid, (37-38%) 225 All Hastelloy B Zinc Sulfate 212 All SS 316

36 Tel: 800.786.4669 | Int’l: 001.508.872.4811


General Use Thermowells
A21A Series

Typical Pressure - Temperature Rating - PSI


NOTES:
Temperature - °F
Material • When ordering, order by Part No. as
70° 200° 400° 600° 800° 1000° 1200° indicated.
Brass 5,000 4,200 1,000
Carbon Steel 5,200 5,000 4,800 4,600 3,500 1,500 • Stainless steel or brass compression
SS304 7,000 6,200 5,600 5,400 5,200 4,500 1,650 fittings are available for mounting
SS316 7,000 7,000 6,400 6,200 6,100 5,100 2,500 probes into these thermowells.
Monel 6,500 6,000 5,400 5,300 5,200 1,500

Specifications
Bore Diameter (B) = 0.260”
Exterior Stem Insertion Shank
Material Material Material Material
Thread Length Length Diameter
SS304 SS316 Carbon Steel Brass
(P) (A) (U) (Q)
Part No. Part No. Part No. Part No.
4 2-1/2 A21A-1 A21A-22 A21A-43 A21A-64
6 4-1/2 A21A-2 A21A-23 A21A-44 A21A-65
9 7-1/2 A21A-3 A21A-24 A21A-45 A21A-66
1/2” NPT 12 10-1/2 5/8” A21A-4 A21A-25 A21A-46 A21A-67
15 13-1/2 A21A-5 A21A-26 A21A-47 A21A-68
18 16-1/2 A21A-6 A21A-27 A21A-48 A21A-69
24 22-1/2 A21A-7 A21A-28 A21A-49 A21A-70
4 2-1/2 A21A-8 A21A-29 A21A-50 A21A-71
6 4-1/2 A21A-9 A21A-30 A21A-51 A21A-72
9 7-1/2 A21A-10 A21A-31 A21A-52 A21A-73
3/4” NPT 12 10-1/2 3/4” A21A-11 A21A-32 A21A-53 A21A-74
15 13-1/2 A21A-12 A21A-33 A21A-54 A21A-75
18 16-1/2 A21A-13 A21A-34 A21A-55 A21A-76
24 22-1/2 A21A-14 A21A-35 A21A-56 A21A-77
4 2-1/2 A21A-15 A21A-36 A21A-57 A21A-78
6 4-1/2 A21A-16 A21A-37 A21A-58 A21A-79
9 7-1/2 A21A-17 A21A-38 A21A-59 A21A-80
1” NPT 12 10-1/2 7/8” A21A-18 A21A-39 A21A-60 A21A-81
15 13-1/2 A21A-19 A21A-40 A21A-61 A21A-82
18 16-1/2 A21A-20 A21A-41 A21A-62 A21A-83
24 22-1/2 A21A-21 A21A-42 A21A-63 A21A-84

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 37


Thermowells
with Lagging Extension
A22A Series

Typical Pressure - Temperature Rating - PSI


NOTES:
Temperature - °F
• When ordering, order by Part No. as Material
indicated. 70° 200° 400° 600° 800° 1000° 1200°
Brass 5,000 4,200 1,000
• Stainless steel or brass compression Carbon Steel 5,200 5,000 4,800 4,600 3,500 1,500
fittings are available for mounting SS304 7,000 6,200 5,600 5,400 5,200 4,500 1,650
probes into these thermowells. SS316 7,000 7,000 6,400 6,200 6,100 5,100 2,500
Monel 6,500 6,000 5,400 5,300 5,200 1,500

Specifications
Bore Diameter (B) = 0.260”
Lagging Exterior Stem Insertion Shank
Material Material Material Material
Extension Thread Length Length Diameter
SS 304 SS 316 Carbon Steel Brass
(T) (P) (A) (U) (Q)
Part No. Part No. Part No. Part No.
2 6 2-1/2 A22A-1 A22A-19 A22A-37 A22A-55
3 9 4-1/2 A22A-2 A22A-20 A22A-38 A22A-56
3 12 7-1/2 A22A-3 A22A-21 A22A-39 A22A-57
1/2” NPT 5/8”
3 15 10-1/2 A22A-4 A22A-22 A22A-40 A22A-58
3 18 13-1/2 A22A-5 A22A-23 A22A-41 A22A-59
3 24 19-1/2 A22A-6 A22A-24 A22A-42 A22A-60
2 6 2-1/2 A22A-7 A22A-25 A22A-43 A22A-61
3 9 4-1/2 A22A-8 A22A-26 A22A-44 A22A-62
3 12 7-1/2 A22A-9 A22A-27 A22A-45 A22A-63
3/4” NPT 3/4”
3 15 10-1/2 A22A-10 A22A-28 A22A-46 A22A-64
3 18 13-1/2 A22A-11 A22A-29 A22A-47 A22A-65
3 24 19-1/2 A22A-12 A22A-30 A22A-48 A22A-66
2 6 2-1/2 A22A-13 A22A-31 A22A-49 A22A-67
3 9 4-1/2 A22A-14 A22A-32 A22A-50 A22A-68
3 12 7-1/2 A22A-15 A22A-33 A22A-51 A22A-69
1” NPT 7/8”
3 15 10-1/2 A22A-16 A22A-34 A22A-52 A22A-70
3 18 13-1/2 A22A-17 A22A-35 A22A-53 A22A-71
3 24 19-1/2 A22A-18 A22A-36 A22A-54 A22A-72

38 Tel: 800.786.4669 | Int’l: 001.508.872.4811


General Use Thermowells
Standard for 3/8” Diameter Elements
A23 Series
A

Typical Pressure - Temperature Rating - PSI


Temperature - °F
Material NOTES:
70° 200° 400° 600° 800° 1000° 1200°
• Stainless steel or brass compression
Brass 5,000 4,200 1,000 fittings are available for mounting
Carbon Steel 5,200 5,000 4,800 4,600 3,500 1,500
SS304 7,000 6,200 5,600 5,400 5,200 4,500 1,650
probes into these thermowells.
SS316 7,000 7,000 6,400 6,200 6,100 5,100 2,500
Monel 6,500 6,000 5,400 5,300 5,200 1,500

Specifications
Bore Diameter (B) = 0.385”
Exterior Element Insertion
Material Material Material Material
Thread Length Length
SS304 SS316 Carbon Steel Brass
(P) (A) (U)
Part No. Part No. Part No. Part No.
4 2-1/2 A23-1 A23-15 A23-29 A23-43
6 4-1/2 A23-2 A23-16 A23-30 A23-44
9 7-1/2 A23-3 A23-17 A23-31 A23-45
3/4” NPT 12 10-1/2 A23-4 A23-18 A23-32 A23-46
15 13-1/2 A23-5 A23-19 A23-33 A23-47
18 16-1/2 A23-6 A23-20 A23-34 A23-48
24 22-1/2 A23-7 A23-21 A23-35 A23-49
4 2-1/2 A23-8 A23-22 A23-36 A23-50
6 4-1/2 A23-9 A23-23 A23-37 A23-51
9 7-1/2 A23-10 A23-24 A23-38 A23-52
1” NPT 12 10-1/2 A23-11 A23-25 A23-39 A23-53
15 13-1/2 A23-12 A23-26 A23-40 A23-54
18 16-1/2 A23-13 A23-27 A23-41 A23-55
24 22-1/2 A23-14 A23-28 A23-42 A23-56

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 39


General Use Thermowells
with Lagging Extension for 3/8” Diameter Elements
A24A Series

Typical Pressure - Temperature Rating - PSI


Temperature - °F
NOTES: Material
70° 200° 400° 600° 800° 1000° 1200°
• Stainless steel or brass compression
fittings are available for mounting Brass 5,000 4,200 1,000
probes into these thermowells. Carbon Steel
SS304
5,200
7,000
5,000
6,200
4,800
5,600
4,600
5,400
3,500
5,200
1,500
4,500 1,650
SS316 7,000 7,000 6,400 6,200 6,100 5,100 2,500
Monel 6,500 6,000 5,400 5,300 5,200 1,500

Specifications
Bore Diameter (B) = 0.385”
Lagging Exterior Stem Insertion Shank
Material Material Material Material
Extension Thread Length Length Diameter
SS304 SS316 Carbon Steel Brass
(T) (P) (A) (U) (Q)
Part No. Part No. Part No. Part No.
2 6 2-1/2 A24A-1 A24A-13 A24A-25 A24A-37
3 9 4-1/2 A24A-2 A24A-14 A24A-26 A24A-38
3 12 7-1/2 A24A-3 A24A-15 A24A-27 A24A-39
3/4” NPT 3/4”
3 15 10-1/2 A24A-4 A24A-16 A24A-28 A24A-40
3 18 13-1/2 A24A-5 A24A-17 A24A-29 A24A-41
3 24 19-1/2 A24A-6 A24A-18 A24A-30 A24A-42
2 6 2-1/2 A24A-7 A24A-19 A24A-31 A24A-43
3 9 4-1/2 A24A-8 A24A-20 A24A-32 A24A-44
3 12 7-1/2 A24A-9 A24A-21 A24A-33 A24A-45
1” NPT 7/8”
3 15 10-1/2 A24A-10 A24A-22 A24A-34 A24A-46
3 18 13-1/2 A24A-11 A24A-23 A24A-35 A24A-47
3 24 19-1/2 A24A-12 A24A-24 A24A-36 A24A-48

40 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Heavy Duty Tapered Thermowells
for 1/4” & 3/8” Diameter Elements
A25 Series
1/4” Diameter Probe - Temperature Rating - PSI A
Temperature °F
Material
70°F 200°F 400°F 600°F 800°F 1,000°F 1,200°F
Brass 5,300 4,750 1,100 - - - -
Carbon Steel 5,950 5,750 5,450 5,250 4,000 1,750 -
SS 304 7,800 7,050 6,400 6,150 6,000 5,190 1,875
SS 316 7,800 7,800 7,250 7,100 6,950 5,800 2,720
Monel 7,450 6,850 6,150 6,100 5,940 1,750 -

3/8” Diameter Probe - Temperature Rating - PSI


Temperature °F
Material
70°F 200°F 400°F 600°F 800°F 1,000°F 1,200°F
Brass 5,000 4,200 1,000 - - - -
Carbon Steel 5,200 5,000 5,800 4,600 3,500 1,500 -
SS 304 7,000 6,200 5,600 5,400 5,200 4,500 1,675
SS 316 7,000 7,000 6,400 6,200 6,100 5,100 2,500
Monel 6,500 6,000 5,400 5,360 5,200 1,500 -

NOTES:
• Stainless steel or brass compression fittings
are available for mounting probes into these
thermowells.

Specifications
Bore Diameter (B) = 0.260”
Shank Diameter Q1-7/8” Q2-5/8”
Exterior Stem Insertion
Thread Length Length Material Material Material Material
(P) (A) (U) SS304 SS316 Carbon Steel Brass
Part No. Part No. Part No. Part No.
4 2-1/2 A25-1 A25-15 A25-57 A25-43
6 4-1/2 A25-2 A25-16 A25-58 A25-44
9 7-1/2 A25-3 A25-17 A25-59 A25-45
3/4” NPT 12 10-1/2 A25-4 A25-18 A25-60 A25-46
15 13-1/2 A25-5 A25-19 A25-61 A25-47
18 19-1/2 A25-6 A25-20 A25-62 A25-48
24 22-1/2 A25-7 A25-21 A25-63 A25-49
4 2-1/2 A25-8 A25-22 A25-64 A25-50
6 4-1/2 A25-9 A25-23 A25-65 A25-51
9 7-1/2 A25-10 A25-24 A25-66 A25-52
1” NPT 12 10-1/2 A25-11 A25-25 A25-67 A25-53
15 13-1/2 A25-12 A25-26 A25-68 A25-54
18 19-1/2 A25-13 A25-27 A25-69 A25-55
24 22-1/2 A25-14 A25-28 A25-70 A25-56
Bore Diameter (B) 0.385”
Shank Diameter Q1-1-1/16” Q2-49/64”
4 2-1/2 A25-29 A25-36 A25-78 A25-71
6 4-1/2 A25-30 A25-37 A25-79 A25-72
9 7-1/2 A25-31 A25-38 A25-80 A25-73
1” NPT 12 10-1/2 A25-32 A25-39 A25-81 A25-74
15 13-1/2 A25-33 A25-40 A25-82 A25-75
18 19-1/2 A25-34 A25-41 A25-83 A25-76
24 22-1/2 A25-35 A25-42 A25-84 A25-77

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 41


Heavy Duty Tapered Thermowells
with Lagging Extension for 1/4” & 3/8” Diameter Elements
A26A Series
1/4” Diameter Probe - Temperature Rating - PSI
Temperature °F
Material
70°F 200°F 400°F 600°F 800°F 1,000°F 1,200°F
Brass 5,300 4,750 1,100 - - - -
Carbon Steel 5,950 5,750 5,450 5,250 4,000 1,750 -
SS 304 7,800 7,050 6,400 6,150 6,000 5,190 1,875
SS 316 7,800 7,800 7,250 7,100 6,950 5,800 2,720
Monel 7,450 6,850 6,150 6,100 5,940 1,750 -

3/8” Diameter Probe - Temperature Rating - PSI


Temperature °F
Material
70°F 200°F 400°F 600°F 800°F 1,000°F 1,200°F
Brass 5,000 4,200 1,000 - - - -
Carbon Steel 5,200 5,000 5,800 4,600 3,500 1,500 -
SS 304 7,000 6,200 5,600 5,400 5,200 4,500 1,675
SS 316 7,000 7,000 6,400 6,200 6,100 5,100 2,500
Monel 6,500 6,000 5,400 5,360 5,200 1,500 -

NOTES:
• Stainless steel or brass compression
fittings are available for mounting
probes into these thermowells.

Specifications
Bore Diameter (B) = ~0.260”
Shank Diameter Q1-7/8” Q2-5/8”
Lagging Exterior Stem Insertion Shank
Extension Thread Length Length Diameter Material Material Material Material
(T) (P) (A) (U) (Q) SS304 SS316 Brass Carbon Steel
Part No. Part No. Part No. Part No.
2 6 2-1/2 A26A-1 A26A-13 A26A-37 A26A-49
3 9 4-1/2 A26A-2 A26A-14 A26A-38 A26A-50
3 12 7-1/2 A26A-3 A26A-15 A26A-39 A26A-51
3/4” NPT 3/4”
3 15 10-1/2 A26A-4 A26A-16 A26A-40 A26A-52
3 18 13-1/2 A26A-5 A26A-17 A26A-41 A26A-53
3 24 19-1/2 A26A-6 A26A-18 A26A-42 A26A-54
2 6 2-1/2 A26A-7 A26A-19 A26A-43 A26A-55
3 9 4-1/2 A26A-8 A26A-20 A26A-44 A26A-56
3 12 7-1/2 A26A-9 A26A-21 A26A-45 A26A-57
1” NPT 7/8”
3 15 10-1/2 A26A-10 A26A-22 A26A-46 A26A-58
3 18 13-1/2 A26A-11 A26A-23 A26A-47 A26A-59
3 24 19-1/2 A26A-12 A26A-24 A26A-48 A26A-60
Bore Diameter (B) = 0.385”
Shank Diameter Q1-1-1/16” Q2-49/64”
2 6 2-1/2 A26A-25 A26A-31 A26A-61 A26A-67
3 9 4-1/2 A26A-26 A26A-32 A26A-62 A26A-68
3 12 7-1/2 A26A-27 A26A-33 A26A-63 A26A-69
1” NPT 7/8”
3 15 10-1/2 A26A-28 A26A-34 A26A-64 A26A-70
3 18 13-1/2 A26A-29 A26A-35 A26A-65 A26A-71
3 24 19-1/2 A26A-30 A26A-36 A26A-66 A26A-72

42 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Flanges
for Thermowells (1/4” & 3/8” Diameter Elements)
A27 Series

Flanges are available in stainless steel 304 and


A
316 and carbon steel (C-1018). Monel and other
materials are available upon request. Primary “J”
groove weld; secondary 45 degree beveled groove
weld.

NOTES:
• (RF - raised face) Standard ASA Serrated
• (FF - flat face), (RTF - ring type flange)

Thermowell must be
specified separately

Flange Specifications

Rating SS304 SS316 Carbon Steel Rating SS304 SS316 Carbon Steel
Size
Facing (lbs./in.2) Part No. Part No. Part No. (lbs./in.2) Part No. Part No. Part No.
(inch)
1 RF A27-1 A27-37 A27-73 A27-19 A27-55 A27-91
1-1/2 RF A27-2 A27-38 A27-74 A27-20 A27-56 A27-92
2 RF A27-3 A27-39 A27-75 A27-21 A27-57 A27-93
1 FF A27-4 A27-40 A27-76 A27-22 A27-58 A27-94
1-1/2 FF 150 A27-5 A27-41 A27-77 400 A27-23 A27-59 A27-95
2 FF A27-6 A27-42 A27-78 A27-24 A27-60 A27-96
1 RTJ A27-7 A27-43 A27-79 A27-25 A27-61 A27-97
1-1/2 RTJ A27-8 A27-44 A27-80 A27-26 A27-62 A27-98
2 RTJ A27-9 A27-45 A27-81 A27-27 A27-63 A27-99
1 RF A27-10 A27-46 A27-82 A27-28 A27-64 A27-100
1-1/2 RF A27-11 A27-47 A27-83 A27-29 A27-65 A27-101
2 RF A27-12 A27-48 A27-84 A27-30 A27-66 A27-102
1 FF A27-13 A27-49 A27-85 A27-31 A27-67 A27-103
1-1/2 FF 300 A27-14 A27-50 A27-86 900 A27-32 A27-68 A27-104
2 FF A27-15 A27-51 A27-87 A27-33 A27-69 A27-105
1 RTJ A27-16 A27-52 A27-88 A27-34 A27-70 A27-106
1-1/2 RTJ A27-17 A27-53 A27-89 A27-35 A27-71 A27-107
2 RTJ A27-18 A27-54 A27-90 A27-36 A27-72 A27-108

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 43


Thermowells
for Flanges (1/4” & 3/8”Diameter Elements)
A28 Series

NOTES:
• Primary weld is a “J” groove type, secondary
• Thermowells available in SS 304, SS 316 weld is a 45 degree bevel groove. All
and C-1018. Monel and other materials may welding is performed by Navy certified
be available upon request. welders using inert gas shielded arc.
• NPSM internal pipe thread will accept NPT • Flanges for use with these thermowells must
and NPS male threads. be specified separately

Flanges to be specified
Thermowell Specifications
separately.
0.264” Bore for 1/4” 0.385” Bore for 3/8”
Diameter Elements - Q=3/4” Diameter Elements - Q=7/8”
SS304 SS316 Carbon Steel SS304 SS316 Carbon Steel
Element Insertion
Part No. Part No. Part No. Part No. Part No. Part No. Length A Length U
A28-1 A28-8 A28-15 A28-22 A28-29 A28-36 4 2
A28-2 A28-9 A28-16 A28-23 A28-30 A28-37 6 4
A28-3 A28-10 A28-17 A28-24 A28-31 A28-38 9 9
A28-4 A28-11 A28-18 A28-25 A28-32 A28-39 12 12
A28-5 A28-12 A28-19 A28-26 A28-33 A28-40 15 15
A28-6 A28-13 A28-20 A28-27 A28-34 A28-41 18 18
A28-7 A28-14 A28-21 A28-28 A28-35 A28-42 24 24

44 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Thermowells
Limited Space for 1/4” Diameter Elements
A29 Series

These thermowells are used where


A
short insertion lengths are required, as in
short legs of tee, etc. Available in stainless
steel SS 304, SS 316, brass ASTM-B16,
carbon steel C-1020, and monel. Choice
of 1/2 inch NPT, 3/4 inch NPT, or one inch
NPT external threads.

NOTES:
• The (brass cap - BRcap) and chain is
• On 1/2 inch NPT external threads, the available for keeping well bore clean when
“U” dimension becomes one inch to not in use. If cap and chain is desired add
accommodate the 1/2 inch NPSM female BRcap to the part number.
thread.
• If (stainless steel - SScap) and chain is
• Stainless steel or brass compression fittings desired, add SScap to the part number.
are available for mounting probes into these
thermowells. • Order by part number as indicated

Specifications
Exterior Maximum Fluid Velocity
Part No. Material
Thread (feet per second)
A29-1 SS 304 300
A29-2 SS 316 300
A29-3 Brass 1/2” NPT 207
A29-4 C-1020 290
A29-5 Monel 261
A29-6 SS 304 300
A29-7 SS 316 300
A29-8 Brass 3/4” NPT 207
A29-9 C-1020 290
A29-10 Monel 261
A29-11 SS 304 300
A29-12 SS 316 300
A29-13 Brass 1” NPT 207
A29-14 C-1020 290
A29-15 Monel 261

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 45


Mullite Protection Tubes
A30 Series

Our line of Mullite protection tubes include a wide range of


diameters, lengths, and fittings to meet most needs. These
protection tubes are available with a plain open end, ceramic
collar or a choice of several metal fittings with various thread
sizes. The composition of Mullite consists mainly of 70% Al2O3
and 28% SiO2. These tubes are cast with one end closed and
they are gas tight. The maximum service temperature is 3,180
degrees Fahrenheit (1,750 degrees Celsius). Ceramic cement is
used to bond the collars and metal fitting to the protection tubes.

Specifications
NOTES: Style A Style B Style C Style D Style E
OD x ID Length Length
• For intermediate lengths, (in.) “L” Part Part “L” Part Part Part
specify Length “L”. No. No. No. No. No.
• Order by Part No. as 6 A30-1 A30-38
indicated 12 A30-2 A30-39
1/8 x 1/16 N/A N/A N/A N/A
18 A30-3 A30-40
24 A30-4 A30-41
6 A30-5 A30-42 5-1/4 A30-80
12 A30-6 A30-43 11-1/4 A30-81
Specify Part No. and length 1/4 x 5/32
18 A30-7 A30-44 17-1/4
N/A
A30-82
N/A
Example: A30-42-36 24 A30-8 A30-45 23-1/4 A30-83
6 A30-9 A30-46 5-1/4 A30-84 A30-93
12 A30-10 A30-47 11-1/4 A30-85 A30-94
3/8 x 1/4 N/A
18 A30-11 A30-48 17-1/4 A30-86 A30-95
24 A30-12 A30-49 23-1/4 A30-87 A30-96

Style Description 12 A30-13 A30-50 11-1/4 A30-88 A30-97


18 A30-14 A30-51 17-1/4 A30-89 A30-98
1/2 x 3/8 24 A30-15 A30-52 23-1/4 N/A A30-90 A30-99

A Plain tube with


One end closed
30
36
A30-16
A30-17
A30-53
A30-54
29-1/4
35-1/4
A30-91
A30-92
A30-100
A30-101
12 A30-18 A30-55 11-1/4 A30-75 A30-102
Plain tube with ceramic collar 18 A30-19 A30-56 17-1/4 A30-76 A30-103

B bonded to open end. Outside


diameter of collar is 1/2 inch
11/16 x 7/16 24
30
A30-20
A30-21
A30-57
A30-58
23-1/4
29-1/4
A30-77
A30-78
N/A A30-104
A30-105
larger than tube diameter. 36 A30-22 A30-59 35-1/4 A30-79 A30-106
Two inch long brass fitting with 12 A30-23 A30-60 11-1/4 A30-107

C 7/8 inch x 27 NS threads bonded


to tube. Available only with 11/16 3/4 x 1/2
18
24
A30-24
A30-25
A30-61
A30-62
17-1/4
23-1/4 N/A N/A
A30-108
A30-109
inch diameter tubes. 30 A30-26 A30-63 29-1/4 A30-110
Contains 1/2 inch x 1/2 inch NPT 36 A30-27 A30-64 35-1/4 A30-111

D fitting bonded to tube. Available


only for tubes from 1/4 inch OD
12
18
A30-28
A30-29
A30-65
A30-66
through 1/2 inch OD. 1 x 3/4 24 A30-30 A30-67 N/A N/A N/A N/A
Contains 1/2 inch x 3/4 inch NPT 30 A30-31 A30-68
36 A30-32 A30-69
E fitting bonded to tube. Available
only for tubes from 3/8 inch OD 12 A30-33 A30-70
through 3/4 inch OD. 18 A30-34 A30-71
1-1/4 x 1 24 A30-35 A30-72 N/A N/A N/A N/A
30 A30-36 A30-73
36 A30-37 A30-74

46 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Protection Tubes
Ceramic and Refractory Metal
A31 Series

We offer high purity Zirconia and Alumina ceramic protection tubes along with Molybdenum
A
and Tantalum metal tubing for high temperature applications. In addition to the size
specifications, additional performance information is available; as well as, other diameters
and types of protection tubes (contact the factory with your specific requirement).
Special Note: Various lengths and diameter sizes are available.

Specifications
Ceramic
OD x ID Length
Part No. Material
(in.) (in.)
A31-1 6
A31-2 12
Alumina 1/8 x 1/16
A31-3 18
A31-4 24
A31-5 6
A31-6 12
Alumina 5/32 x 5/64
A31-7 18
A31-8 24
A31-9 6 Refractory Metal
A31-10 12
Alumina 1/4 x 3/16
A31-11 18
A31-12 24
A31-40 6
A31-41 12
A31-42 18
Alumina 3/8 x 1/4
A31-43 24
A31-44 30
A31-45 36
A31-50 6
A31-51 12
A31-52 18
Alumina 1/2 x 3/8
A31-53 24
A31-54 30
NOTES:
A31-55 36 • For ceramic protection tubes order by Part No.
A31-61 12 (Example: A31-1, specifies a six inch long 1/8
A31-62 Zirconia 1/4 x 3/16 18 OD x 1/16 ID alumina tube).
A31-63 24
• All ceramic tubes come closed end, for ceramic
A31-70 6 tubes open both ends, specify as follows
A31-71
Zirconia 3/8 x 1/4
12 Example: A31-12-9-OBE
A31-72 18
A31-73 24 • Tubes are typically made in six inch increments.
You must specify a base Part No. longer than
Refractory Metal Tubing
your required cut lengths when ordering (OBE
Open Both Ends
- open both ends). Example: 12 inch tube open
Part No. Material
OD x ID Length both ends requires an 18 inch tube to be cut
(in.) (in.) down.
A31-80 0.125 x 0.015 108 • For refractory tubing with one end welded
A31-81 Tantalum 0.187 x 0.020 108 closed and leak tested to 80 PSI contact factory.
A31-82 0.250 x 0.030 108
A31-90 0.125 x 0.015 98
• For refractory tubing, list Part No. and length
A31-91 0.187 x 0.020 98
of the tube (Example: A31-92-24, specifies
A31-92
Molybdenum
0.250 x 0.030 98 molybdenum tubing, 1/4 inch OD with 0.030
A31-93 0.250 x 0.050 98 thick wall, 24 inches long, open both ends).

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 47


Heavy Duty Protection Tubes
A32 Series

NOTES: • All of these protection tubes can be made


with thermocouple elements installed and in
• Typically, the materials shown here are various configurations for your convenience.
used for temperatures below 2,400 degrees
Fahrenheit. For temperatures above this • Specify Part No. and length “L”
range contact factory. Example: A32-5-48
For temperature sensors utilizing these protection tubes or
for special design requirements contact Nanmac.

* Silicon Carbide * Cast Silicon Carbide Plain Steel Pipe


(molded onto pipe) (no pipe)

* Minimum order - 12 pieces

Specifications
ID x OD Max. Length
Part No. Material NPT Style
(in.) (in.)
A32-1 Inco 601 0.622 x 0.840 1/2” 60
A32-2 Inco 601 0.824 x 1.050 3/4” 60 N/A
A32-3 Inco 601 1.049x 1.315 1” 60
A32-4 SS 304 0.622 x 0.840 1/2” 60
A32-5 SS 304 0.824 x 1.050 3/4” 60 N/A
A32-6 SS 304 1.049x 1.315 1” 60
A32-7 SS 446 0.622 x 0.840 1/2” 60
A32-8 SS 446 0.824 x 1.050 3/4” 60 N/A
A32-9 SS 446 1.049x 1.315 1” 60
A32-10 Silicon Carbide 1 x 1-3/4 - 48 Plain Pipe
A32-11 Silicon Carbide 1 x 1-3/4 - 48 with Collar
Silicon Carbide
A32-30 0.59 x 2.0 1/2” 48 N/A
Molded to Steel
Silicon Carbide
A32-31 0.79 x 2.0 3/4” 48 N/A
Molded to Steel

48 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Heavy Duty Thermocouple Assemblies
with Metal Alloy Protection Tubes
A33 Series
A

Our standard assembly consists of the metal alloy protection tube with a general purpose
aluminum connector head attached. The connector head has a 1/2 NPT outlet port. This
unit is assembled with a Chromel Alumel (Type K) ungrounded thermocouple with ceramic
insulators and is connected to a two-wire ceramic terminal block in the connector head.

Type J, K, or N available

Specifications
Max. Sheath
Exposed Junction
Sheath
Part No. Sheath OD x ID
Material
Length (in.)
A33-10 0.540 x 0.364
A33-11 0.840 x 0.622
Inconel 601 60”
A33-12 1.050 x 0.824
A33-13 1.315 x 1.049
A33-14 0.540 x 0.364
A33-15
SS 304 60”
0.840 x 0.622 Grounded Junction
A33-16 1.050 x 0.824
A33-17 1.315 x 1.049
A33-18 0.540 x 0.364
A33-19 0.840 x 0.622
SS 446 60”
A33-20 1.050 x 0.824
A33-21 1.315 x 1.049
A33-22 0.540 x 0.364
A33-23 0.840 x 0.622
A33-24
Carbon Steel 60”
1.050 x 0.824 Ungrounded Junction
A33-25 1.315 x 1.049
A33-26 0.540 x 0.364
A33-27 0.840 x 0.622
Hastelloy C 60”
A33-28 1.050 x 0.824
A33-29 1.315 x 1.049

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 49


Angle Type Extension Assemblies
A34 Series

In addition to straight assembly units, we offer a right angle type cold leg extension. We
use a general purpose (GP) connector head to make the bend instead of using a pipe elbow.
This GP connector allows easier maintenance, servicing and replacement of components;
thus reducing your overall costs.

The cold leg consists of a carbon steel pipe of a specified length with 1/2” NPT threaded
ends. The carbon steel extension terminates in a GP connection head with a 2 wire terminal
block inside, the exit port is 1/2” NPT. Maximum service temperature of the cold leg and the
GP connector is 1,000 degrees Fahrenheit.

When ordering this cold leg extension assembly, start with the
Part No. of the thermocouple or RTD assembly you require.

NOTES:
• Add the suffix CL (cold leg) and
the length of the CL to the
Part No.
• Example: A33-1-18-CL-24,
specifies an A33-1 Thermocouple
with an 18 inch sheath, and
cold leg (CL) extension with
a length of 24” (for special
design requirements contact the
factory).

Specifications
Cold Leg Length
18”
24”
30”
36”

50 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Thermocouples
with Ceramic Protection Tubes
A35 Series
A

Our thermocouple assemblies with various ceramic protection tubes are designed for high
temperature applications. All units use a stainless steel support tube which protects the
ceramic sheath from breakage while using an adjustable mounting adaptor. All units are
closed end and are gas tight, these units can be used in vacuum furnaces. A secondary
wire seal is made at the terminating end to assure a vacuum tight seal even if the ceramic
hot section is damaged. All units have an ungrounded thermal junction.
NOTES: • When ordering specify Part No. probe
length and thermocouple type.
• All units come with an aluminum connector
head. • Example: A35-10-18-K, specifies type K with
alumina sheath which is 18 inches long and
• For a steel support tube longer than four 0.375 OD.
inches contact factory.
• All units come with a stainless steel support
• Adjustable compression fittings are available tube which is four inches long and 1/8 inch
for use with these probes. larger in diameter than the sheath diameter.

Specifications
Sheath Maximum Support Tube
Sheath
Part No. Diameter Length Diamter Type
Material
(in.) (in.) (in.)
A35-10 Alumina 0.375 36 0.500
A35-11 Alumina 0.500 36 0.625
A35-12 Alumina 0.750 36 1.000
A35-13 Mullite 0.375 24 0.500
E, J, K, T
A35-14 Mullite 0.500 36 0.625
A35-16 Zirconia 0.250 18 0.375
A35-17 Zirconia 0.375 24 0.500
A35-18 Quartz 0.250 36 0.375

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 51


NC-11 Advanced Thermocouple Assemblies
for Molten Metals
A37 Series

Our thermocouple assemblies with NC-11 protection sheaths are designed for high
temperature use. Our metal-ceramic protection tube NC-11 is a hard, abrasion-resistant,
dense material made from two high temperature compatible materials. The combination
of this high temperature metal and oxide produces a product with three very important
properties. The properties are: superior oxidation resistance to 2,500 degrees Fahrenheit,
thermal conductivity comparable to that of stainless steel, and good resistance to wetting by
most molten metals.
Applications Include:
• Molten copper and brass to 2,100 degrees • Molten zinc to 1,600 degrees Fahrenheit
Fahrenheit intermittent and continuous
immersions. • Molten lead to 650 degrees Fahrenheit
• Corrosive SO and SO gas (to 2,500 degrees • Basic steel and stags to 3,150 degrees
Fahrenheit) and SO and HP gas (to 2,000 Fahrenheit (intermittent) and 2,500 degrees
degrees Fahrenheit). Fahrenheit (continuous in open hearth and
general foundry practices).
• Open hearth furnace checker chambers to
2,450 degrees Fahrenheit. • Fluid bed cement process with severe
corrosion and temperature to 2,400 degrees
• Pelletizing chamber of Taconite refining Fahrenheit (fluid method of producing
operation to 2,100 degrees Fahrenheit. builders cement).

Specifications
Length
Part No. Type of Mounting
(in.)
A37-1-12-(specify: J, K , N) 12
A37-1-18-(specify: J, K , N) 18 Five inch long, one inch NPT,
A37-1-24-(specify: J, K , N) 24 stainless steel support tube.

A37-1-30-(specify: J, K , N) 30 Other support tube lengths


A37-1-36-(specify: J, K , N) 36 available upon request.

A37-1-48-(specify: J, K , N) 48

52 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Advanced Thermocouple Assemblies
for Molten Aluminum
A38 Series
A

The NC-12 protection tube is a dense, sintered ceramic especially designed for use
in many molten non-ferrous metals and corrosive chemicals. It is very strong, thermally
shock resistant and dimensionally stable. Additionally NC-12 is vacuum-tight and has high
electrical resistance. Mechanical strength is retained at extremely high temperatures (over
1,000 degrees Celsius in air). These features together with very low wear resistance, makes
NC-12 an ideal thermocouple protection tube for applications such as molten aluminum,
lead, tin, and zinc. Preheating is not necessary because NC-12 has a very low thermal
expansion coefficient.

Our NC-12 Protection tubes are also recommended for use in oxidizing environments
to 2,200 degrees Fahrenheit. Most acids, such as hydrochloric, nitric, sulphuric, and
phosphoric, do not attack NC-12. This material is also resistant to hydrogen gas. It is not
recommended for use with caustic solutions and hydrofluoric acid.
NOTES: • This support tube is of universal design. It
comes in either one inch of 1-1/4 inch NPT
• Standard units come with thermocouple pipe threads (depending on diameter of
type K installed. protection tube).
• For duplex units or other calibrations • Complete with wrench flats for easy
contact factory. installation and it can accept flanges.
• Standard support tube is five inches long of • Longer length support tubes are available
stainless steel. (contact factory).

Typical Test Results of NC-12


Resistance to Molten Metals
Specifications
Holding Time
Material °F °C Remarks
in Hours Diameter Length NPT
Part No.
“D” “L” “N”
Aluminum 1,800 987 3,000 No Attack
Lead 752 400 144 No Attack A38-1 1 19-1/2 1”
Tin 872 300 144 No Attack A38-2 1 25-1/2 1”
Zinc 1,022 850 500 No Attack A38-3 1-1/4 37-1/2 1-1/4”
Magnesium 1,382 750 20 Slightly Attacked A38-4 1-1/4 49-1/2 1-1/4”
Copper 2,120 1,150 7 Badly Attacked A38-5 1-1/4 56-1/2 1-1/4”

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 53


Ribbon Thermocouples
Exposed
B2 Series

NOTES:
• When ordering intrinsic thermocouples
• When ordering specify part number, simply add the suffix IT to the part number
thermocouple calibration type, and length of desired configuration of the flexible
in inches (standard length is 12 inches). Ribbon Thermocouple.
Example: B2-3-J-20 Example: B2-4-K-24-IT

Figure 1

Figure 2

Figure 3
(Intrinsic design, no premade thermal junction)

Specifications
Wire Diameter Ribbon Thickness Stainless Steel
Part No. Insulation
(in.) (approximate) Sheath (dia.)
B2-1 0.005 0.001” fiberglass -
B2-2 0.010 0.0015” fiberglass -
B2-3 0.020 0.0025” fiberglass -
B2-4 0.006 0.001” ceramic 0.040”
B2-5 0.013 0.0015” ceramic 0.062”
B2-6 0.020 0.0025” ceramic 0.125”

54 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Ribbon & Weldable Tab Thermocouples
for Surface Temperatures
B4 Series

The Model RCF thermocouple has a flat ribbon sensing tip (1/2 inch wide by 7/9 inches B
long by ~0.002 inches thick) with 36 inches of flexible fiberglass leads. This model has low
millisecond response times.

The Model RCS thermocouple is similar to Model RCF except, it has a 12 inch long
stainless steel clad, ceramic packed extension shaft. As a result, the sensor can operate
up to temperatures of 2,000 degrees Fahrenheit maximum, depending upon thermocouple
type and duration of exposure.

The Model WT weldable tab thermocouple has a 3/4 inch by 3/4 inch by 0.030 inch thick
stainless steel welding tab, brazed onto a grounded junction (1/8 inch OD thermocouple). It
also has 36 inches of fiberglass insulated extension leads. The sensing tip has a maximum
service temperature of 1,000 degrees Fahrenheit.

Model RCF

Model RCS

Model WT

Specifications
“A” “B” “C”
Part No. Model Wire Size (in.)
Dimension (in.) Dimension (in.) Dimension (in.)
B4-1 0.020 7/8 1/2 -
RCF
B4-2 0.013 5/8 3/8 -
B4-3 0.020 7/8 1/2 1/8
RCS
B4-4 0.013 5/8 3/8 1/16
B4-5 0.020 - - 1/8
WT
B4-6 0.013 - - 1/16

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 55


Rub & Contact Thermocouples
Ideal for Moving Surfaces: Drums • Fibers • Wire • Etc.
B6 Series

RDD Model Mounting Block

FFM Model

Specifications
NOTES: Part No. Model
• Specify part number and thermocouple B6-1 RDD with Mounting Block
type when ordering. B6-2 FFM with Mounting Block
Example: B6-1-K B6-4 RDD only
B6-5 FFM only
B6-6 Mounting Block only

Model RDD Thermocouple - Specifications Model FFM Thermocouple - Specifications


Soft brass disc brazed to thermocouple Self-renewing thermal junction mounted
element, disc and thermocouple is in V-notch machined in thermowell which is
mounted into a high temperature plastic Description spring-loaded inside aluminum mounting
housing, which is spring-loaded in the block. Three feet of fiberglass leads are
Description aluminum mounting block. Standard is standard.
36 inches of fiberglass insulated leads,
Direct contact with fine fibers and metal
though most any lead configuration and
wires, such as for controlling pre-induction
plug assembly can be added. The device Applications
heaters during fiber processing, plastic
uses a spring rate of 5.83 lbs./in.
coating of wires, fiber processing, etc.
Direct contact with rotating drums and
Applications Response time: low milliseconds; 450
discs or moving plates and sheets.
degrees Fahrenheit maximum service
temperature; maximum wire speed: 3,000
Performance
30 second response time; 450 degrees fpm. Self-renewing junction provides
Performance
Fahrenheit maximum service temperature. accurate sensing until 3/8” has worn off tip
of FFM sensor.

56 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Ribbon Thermocouples
with Retractable Shield for Surface Contact Measurements
B7 Series

Our Ribbon Thermocouples for surface temperature measurement contains a 0.002 inch
thick loop-ribbon junction inside a spring-loaded protective shield. When applied against any
surface, the protective shield retracts enough to allow the ribbon junction to make intimate
contact with the wall. Because the ribbon junction eliminates conduction errors caused
by the stem of the thermocouple, surface temperature of any wall or object is measured
accurately. Response time of this new design is in the low milliseconds. Temperature range
is from cryogenic to 600 degrees Fahrenheit (higher temperature ranges on special request).

NOTES:
• Low mass sensing elements • Available in thermocouple calibration type K
• Large contact area improving accuracy and • When ordering specify by part number
eliminates conduction errors.
• All standard units are straight probes. If a
• Spring loaded protective shield protects 90 degree bend is desired, add (-90) to the
probe from physical damage and produces part number.
the same contact pressure in each Example: B7-1-90
application. It also contacts the object at
only five points; thus, minimizing any local • Special units with other dimensions are
thermal disturbances. available upon request.

Applications
• Hot Plates • Plastics Processing
• Surfaces • Machinery
• Walls • Ducts
• Ovens • Steam Lines
• Bearings • Air
• Engine Blocks • Gases, etc.

Specifications
Part No. Termination Style Type
Transition splice with spring relief plus 12 inches of coiled
B7-2 K
retractable cable with miniature male connector attached.
Plastic handle with spring relief plus 12 inches of coiled
B7-3 K
retractable cable with miniature male connector attached.

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 57


Handheld Thermocouples
for Surface Contact Measurement
B8 Series

The Trident Thermocouple probe has an exposed ribbon style element. The ribbon element
is 0.002 inches thick, by 0.060 inches wide. Featuring spring-like stainless steel side guards
to protect the element from accidental damage. This sensor has no measurable conduction
error and is ideal for all types of surface contact measurements. Examples include: cloth,
textiles, thin plastics, rotating drums, hot plates, and/or any surface whose temperature is
desired. This sensor can even measure the temperature difference between black and white
on a sheet of paper when heated by a 60 watt light bulb from a distance of two feet.

Response time of this Trident probe is in the low milliseconds and usually limited only by
the meter taking the temperature readings. Standard termination style is a four inch plastic
handle, PVC insulated coil cord and mini thermocouple connector.

Trident Style

Specifications
NOTES:
Part No. Style Termination Type
• For special style surface probes or other B8-9 J
dimensions, terminations, or calibrations B8-10
Trident Style Plastic Handle
K
contact the factory. B8-11
Ribbon Coil Cord and
E
Thermocouple Mini-Connector
B8-12 T

58 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Spring-Loaded Ribbon Thermocouples
B9 Series

This spring-loaded thermocouple is designed for


threaded blind-hole measurements, surfaces subject to
vibration/oscillation, and any application where positive
contact for good measurement is required.

The sensing tip of this device consists of a thin ribbon


B
thermocouple element overlapped onto a phenolic rod.
This rod is spring-loaded within the threaded stainless
steel thermowell body. Thus, the sensing tip can be
depressed up to an 1/8 inch while it continuously
maintains good thermal contact to the object whose
temperature is being measured. The combination of the
thin ribbon thermocouple and low thermal conductivity
of the phenloc rod yield response times in the low
200 milliseconds. This combination also provides
temperature measurements without conduction errors.
The true temperature of the test item is monitored.

All units come with a Delrin locking element (slug), which when used resists loosening due
to vibration. However, this limits the upper temperature limit to 300 degrees Fahrenheit. The
Delrin slug can easily be removed with a pair of pliers, increasing the upper temperature limit
to 450 degrees Fahrenheit. If higher temperatures are required please provide us with your
particular requirement.

NOTES:
• Low millisecond response times in
contact applications.
• Temperature rating to 450 degrees
Fahrenheit.
• Self-locking Delrin plug
• Choice of thermocouple types E, J,
K, N & T
• All units come with 48 inches of
teflon insulated lead wire.

Specifications
Thread Thread Rod Rod Dia. Force (lbs.)
Part No.
Size (in.) Length (in.) Length (in.) (in.) Initial - Final
B9-1(*) 1/4-28 1 3/16 0.090 1.0 - 4.0
B9-2(*) 3/8-16 1-1/8 3/16 0.187 2.8 - 7.2
B9-3(*) 1/2-13 1-1/4 1/4 0.248 2.7 - 9.3
B9-4(*) 5/8-11 1-1/2 5/16 0.310 10.5 - 25.5

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 59


Right-Angle Ribbon Thermocouples
for Air, Gas, Liquid, Blind-Hole
and Immersion Temperature Measurement
C1 Series

The Right-Angle Ribbon Thermocouple features thermal


elements which consist of thin thermocouple alloy ribbons
welded together at the sensing tip. These ribbon elements
are brought out from opposing sides of the probe along
the interface of a high temperature thermally isolating
rod and cone assembly. The ribbons in the vicinity of the
thermal junction are parallel to the plane of heat source.
Thus, both the thermal junction and the ribbons are heated
simultaneously and conduction errors are minimized.

The ribbon elements, due to their mass to surface-area relationship; provide fast response
times to equilibrium temperatures since the maximum surface contact area is offered to the
heat source.
• Probe materials may be metal, plastic, or
NOTES: ceramic
• Response times of 18 milliseconds in boiling • Mountings may be adjustable compression
water tests fittings on fixed mountings
• Pressure ranges to 10,000 psi, temperature • All standard thermocouple calibrations and
ranges to 3,200 degrees Fahrenheit connectors available.

The test record below is a reproduction of temperature versus time data


obtained by manually immersing the Right-Angle Thermocouple from ice water
to boiling water then back to ice water.

60 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Right Angle Ribbon Thermocouples
C2 Series

The adjustable probe unit includes an adjustable compression fitting with standard pipe
threads. The probe may be from 3/16 inch OD and up, though standard sizes are 1/4 and
3/8 inch. Lengths can be from one inch to as much as 24 inches long, with a standard length
of four inches. Probe may be made from most any metal, plastic, or phenolic compound.
This style is ideally suited for gas and liquid surface and immersion applications.
C
The Surface mounted unit contains the right angle thermocouple on the end of the
threaded thermowell. The thermowell is stainless steel with straight threads (7/16 NF-2 by
13/32 inches long). It also contains an O-ring seal (good to 450 degrees Fahrenheit). At
higher temperatures, the O-ring must be removed and replaced by a copper washer. This
fluid mounted unit is ideal for applications requiring gas or liquid temperatures at the inner
surface of a container wall.

The fixed probe unit contains a 1/4 inch OD stainless steel probe on the end of a straight
thread mounting bushing (size of threads 1/2-20 NF x 3/4 inches long). The fixed probe unit
is ideal for measuring gas or liquid temperatures inside a container under high pressures.

Available in all thermocouple types


Many other configurations available

Specifications
Diameter Length Maximum
Probe Mounting
Part No. “A” “L” Pressure
Material Type
(in.) (in.) (psi)
C2-1 SS 304 1/4 OD 4 1/8 NPT 3,000
C2-2 SS 304 3/8 OD 4 1/4 NPT 3,000
C2-3 Inconel 1/4 OD 4 1/8 NPT 3,000
C2-4 Copper 1/4 OD 4 1/8 NPT 3,000
C2-5 SS 316 - - 7/16-20 NF by 13/32 5,000
C2-7 SS 304 1/4 OD 4 1/2-20 NF by 3/4 10,000

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 61


Extruder Thermocouples
for Plastic Melt Temperatures
C2B Series

Our plastic melt thermocouples are designed for


use in extruder heads or die adaptors of injection
molding machines with the thermocouple sensor
either flush or immersed into the plastic melt.

The thermowell and sensor sheath are made of


304 stainless steel. Standard units have a Type
J junction electrically grounded to the tip. The
flexible design has a flexible 12 inch armored
extension, plus a connector plug.
NOTES:
• If longer than twelve inches of armor flexible • All of these standard melt thermocouples
leads are needed, contact factory. have a grounded iron/constantan (type J)
junction. Other calibrations available upon
• Contact factory for ungrounded or duplex request.
units and other calibrations.

Rigid Design

Flexible Design

Rigid Design Specifications Flexible Design Specifications


Part No. Dimension “A” Dimension “B” Part No. Dimension “A” Dimension “B”

C2B-1 Flush C2B-11 Flush


C2B-2 1/4 C2B-12 1/4
C2B-3 1/2 3 C2B-13 1/2 3
C2B-4 3/4 C2B-14 3/4
C2B-5 1 C2B-15 1
C2B-6 Flush C2B-16 Flush
C2B-7 1/4 C2B-17 1/4
C2B-8 1/2 6 C2B-18 1/2 6
C2B-9 3/4 C2B-19 3/4
C2B-10 1 C2B-20 1

62 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Right-Angle Ribbon Thermocouples
with Dust Deflector
C5 Series

This series of the Right-Angle Ribbon Thermocouple


features a Dust Deflector on the sensing tip. This
deflector is in the shape of an arc and covers a 120
degree angle around the sensing tip. When foreign
matter such as such as dust particles, dirt, and other
small solid objects impact the Dust Deflector, that
matter is then diverted off the sides of the probe. Thus,
protecting the thin ribbon elements from damage. The
thermal junction measures the temperature of the hot
C
gases and/or liquids without being damaged by the dust
particles. A peen mark is stamped onto the thermowell
at the cold end to assist in aligning the probe so that
the dust deflector is facing directly into the oncoming
gas flow.

This Right-Angle Ribbon sensor features a thermal junction of thin ribbons welded together
at the sensing tip. These ribbons are brought out from opposing sides of the probe between
the interface of an insulting rod and cone assembly. The ribbons in the vicinity of the media
being measured are parallel to the plane of the heat source. Thus, both the ribbons and
the thermal junction are heated simultaneously and conduction errors are eliminated. The
ribbon elements also allow for fast response times to temperature change. Since there
is a large surface area to cross-section area ratio in the ribbon design as compared to
round wires.

NOTES:
• Standard probe comes with a two-prong
standard plug connector attached. Mating jack
connector with cable clamp is furnished with
each unit.
• Thermocouple junction has no conduction
errors
• Pressure range to 4,000 psi
• Low millisecond response time to temperature
changes
• Temperature range from -320 to 2,000 degrees
Fahrenheit
• Available in thermocouple calibration types E,
J, K, N, and T
• When ordering specify part number C5
and thermocouple calibration type.
Example: C5-J

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 63


Right-Angle Ribbon Thermocouples
with Stainless Steel Diaphram Tip for Sanitary Applications
C6 Series

This series of Right Angle Ribbon Thermocouple features a stainless steel diaphragm
over the ribbon thermal junction. This diaphragm is 0.015 inches thick. The design is used
whenever a 100% sanitary requirement is required. Applications such as manufacturing
foods or medicines occasionally require this feature.

This Right Angle Ribbon Thermocouple sensor features a thermal junction of thin ribbons
welded together at the sensing tip. These ribbons are brought out from opposing sides
of the probe between the interface of an insulating rod and cone assembly. The ribbons
in the vicinity of the media being measured are parallel to the plane of the heat source.
Thus, both the ribbons and the thermal junction are heated simultaneously and conduction
errors are eliminated. The ribbon elements also allow for fast response times to temperature
change. Since there is a large surface area to cross-section area ratio in the ribbon design
as compared to round wires.

This assembled ribbon junction is then installed into a special thermowell which has a
0.015 inch thick diaphragm on its tip. Thus, the thermal junction is now in intimate thermal
contact with the stainless steel diaphragm. This produces an electrically grounded thermal
junction. When an ungrounded junction is desired, a thin disc of electrical insulating material
is inserted between the junction and the diaphragm. Special attention is made to use a
material with good heat transfer properties.
NOTES:
• Standard probe comes with a two-prong standard plug
connector attached.
• Mating jack connector with cable clamp is furnished with
each unit.
• Contact us for special units and other calibrations
• Fast response times
Specifications
• Minimum conduction errors
Part No. Type
• Available in types E, J, K, N & T
C6-J J
• Pressure range to 500 psi C6-K K
C6-E E
• Temperature range from C6-T T
-320 to 2,000°F

64 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Extrude-O-Couple
Reference
C8 Info

This device utilizes the patented Self-Renewing Thermocouple


junction design. This very special design proves low millisecond
response times to temperature changes. Also, the sensing tip
is thermally isolated from the thermocouple housing. Therefore,
the actual (true) temperature of the plastic is measured.

The C8-ME model Extrude-O-Couple is a one-piece stainless


steel unit designed for use in small extruder nozzles. It is installed
flush with the inside surface of the nozzle throat. Thus, offering no C
obstruction to plastic flow. Most any type of connector can be attached to the thermocouple.
The Nanmac C8-ME model is available in thermocouple calibration types E, J, K, N & T.

The C8-SE model Extrude-O-Couple is designed to fit into standard holes existing in
most nozzles for thermocouple or pressure gauge applications. This thermocouple has a
two-piece stainless steel thermowell which allows for better sealing at the conical surface,
automatically self aligning even in slightly offset machined holes. All connector types are
available, as are thermocouple types E, J, K, N & T.

The C8-LE model Extrude-O-Couple is designed for use on thick-walled extruder nozzles
requiring long thermocouples to fit into deep holes. Also it is designed to fit into holes in most
nozzles which are modified to receive thermocouples or pressure gauges. The Nanmac
C8-LE is a three-piece assembly thermocouple,
Model ME
rotating gland nut and a spacer. The length of
the spacer must be specified to accommodate
your requirements. The C8-LE model is available
in thermocouple types E, J, K, N &T. When
ordering specify model number, calibration, and
dimension “L” to the nearest 1/8 inch.
Model SE
Specifications
Part No. Model Type
C8-1 E
C8-2 J
ME
C8-3 T
C8-4 K
Model LE
C8-5 E
C8-6 J
SE
C8-7 T
C8-8 K
C8-9 E
C8-10 J
LE
C8-11 T
C8-12 K

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 65


Thermocouple
for In-Stream Plastic Melt
C8A Series
Oftentimes, it is desirable to measure the true temperature of
flowing plastic in an extruder nozzle. This device will provide
valuable information regarding the mixing characteristics of:
plastic melt, efficiency of the screw, accurate temperature profile
of the plastic melt, magnitude, and shape of the temperature
profile across the stream.

Nanmac has designed two special thermocouples with low


millisecond response times to measure the in-stream temperatures.
One with a Fixed Immersion Tip and the other with an Adjustable
Immersion Tip. Both are designed to minimize conduction errors
and are available in thermocouple types E, J, K, N & T.

The Fixed Immersion Tip unit includes a gland nut and a thermowell. The sensing tip
of the thermowell has a wedge shaped tip to minimize the shear effects. Therefore, the
leading edge of the wedge must face up-stream (into the oncoming plastic). A peen mark
is machined onto the thermocouple near the connector to indicate orientation for this
unidirectional installation. Also, wrench flats are provided to hold the thermocouple in place
while tightening the gland nut. Maximum service temperature and pressure rating of this unit
is 750 degrees Fahrenheit and 20,000 psi respectively.

The Adjustable Immersion Tip unit in similar to the fixed unit; except, the immersion length
is adjustable to any depth from flush on inner wall (to one inch immersion). Also, the sensing
tip is omnidirectional instead of unidirectional and spherically shaped to minimize shear
effects. On the connector end of this unit there are circular grooves machined into the shaft
at 1/10 inch intervals. These grooves are for indicating the insertion depth of the sensing tip
while the unit is installed. After installation and before plastic hardens/freezes you simply
screw the thermowell in or out to the desired insertion depth. An internal O-ring provides a
leak tight seal to 10,000 psi at melt temperatures of up to 600 degrees Fahrenheit. Adjustment
needs to be done either while
plastic is in its liquid state or upon
initial installation when there is no
plastic present.

Specifications
Dimension
Part No. Description
“A” (inches)
C8A-1 Fixed 1/2
C8A-2 Fixed 3/4
C8A-3 Fixed 1
* C8A-4 Adjustable 1/4 - 1-1/4

* Not Shown - Contact Factory

66 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Mixer Temperature Sensors
Available for Sanitary Applications
C10 Series

The MCR Model has an exposed flush-mounted ribbon Cutaway view of typical installation
thermocouple on its conical sensing tip. The one-piece
stainless steel thermocouple well is designed for internal
type installation secured with lock washers and jam nut.
Each unit is furnished with jam nuts, lock washers and
three feet of fiberglass insulated lead wire. Suitable for use
to 2,000 psi at temperatures to 400 degrees Fahrenheit.
MCR Model
The MDA Model has an exposed flush-mounted
ribbon thermocouple on its sensing surface. The one-
C
piece stainless steel thermocouple well is designed for
external type installation using the stainless steel gland
nut and three feet of fiberglass insulated extension leads.
Suitable for use to 2,000 psi at temperatures to 400 MDA Model
degree Fahrenheit.

The MCR-SS Model has a stainless steel diaphragm


on its conical sensing tip. The stainless steel diaphragm
encloses the ribbon thermocouple and thus this is a 100%
sanitary and contamination-free design. The ribbon
element is electrically grounded to the stainless steel MCR-SS Model
diaphragm. (Electrically insulated models are available
upon request.) Each unit is furnished with jam nut, lock
washers, and three feet of teflon insulated extension leads.
Suitable for use to 500 psi at 400 degrees Fahrenheit.

The MDA-SS Model has a stainless steel diaphragm


on its conical sensing tip (similar to the MCR-SS above). MDA-SS Model
This model is designed for external type of installations.
A stainless steel gland nut and three feet of fiberglass
insulated leads are supplied with each unit.

All units require a Teflon® conical seal, which can be


Specifications ordered directly from the factory.
Part No. Model
C10-10 MCR
C10-12 and C10-13 units are also available with RTD
C10-11 MDA sensors, and are of sanitary design.
C10-12 MCR-SS
C10-13 MDA-SS
C10-14 MCR-Plug Dummy plugs are available to plug up the thermocouple
C10-15 MDA-Plug
hole when the sensor is removed or not in use.

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 67


Mixer Thermocouple Mounting Accessories
eliminating the Need for Detailed Machining
C11 Series

All pre-machined receptacles have a two inch


diameter and length “L” as specified. You only
need to machine two inch holes in your mixer
wall. Then, install the required receptacle. All this
finesse machining has been done to the receptacle
threads, through-hole, conical taper, etc.

Stainless steel 316 receptacle (MDA series)


designed to be welded into mixer wall. Available with
dimension “L” from 1-1/4 to 4-1/2 inches increments
of 1/4 inch. The MDA series mixer thermocouple
requires one teflon conical seal (Part No. C11-60).

Stainless Steel 303 spacer (MDA series) for


use with MDA series receptacles. Available with dimension “L” from 1/4 to 3-1/4 inches
increments of 1/4 inch. Spacer length “L” is always 1-1/4 inches shorter than dimension “L”
of receptacle. This spacer is not required if dimension “L” of MDA series receptacle is 1-1/4
inches.

Stainless steel 316 receptacle (MCR series) designed to be welded into mixer wall. Available
with dimension “L” from 1-1/4 to 4-1/2 inches increments of 1/4 inch. The MCR series mixer
thermocouple requires one teflon conical seal (Part No. C11-70).

Special sizes available - Contact Factory

Specifications
MDA Receptacle MCR Receptacle
Dimension
Part No. Description
“L”
C11-2 1-1/2
C11-6 2-1/2 MDA Receptacle,
C11-12 4 SS 316
C11-13 4-1/4
MDA Spacer,
C11-20 1/4 SS 303
C11-30 2-3/4 Required for MDA receptacle.
MDA Spacer Conical Seal Conical Seal C11-31 3 Spacer is 1-1/4” shorter than
receptacle.
(MDA) (MCR) C11-40 1-1/4
C11-43 2
MCR Receptacle,
C11-47 3
SS 316
C11-51 4
C11-53 4-1/2
C11-60 MDA Teflon
C11-70 MCR Conical Seal

68 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Flow-Thru Thermocouples & RTDs
Simple Installation Into Any Pipeline
D1 Info

Flow-Thru temperature sensors use


either the Nanmac Right-Angle Ribbon
Thermocouple or a Pt100 ohm RTD. The Right-
Angle Ribbon Thermocouple utilizes a special
ribbon element which eliminates conduction
error due to shallow immersion in the flowing
gas or liquid within the pipeline.

NOTES:
Applications:
• Thermocouple junction has minimal conduction
errors • Chemical Processing
• Junction can be located flush with inner wall • Heat Exchangers D
surface or protruded into the flowing media • Oil, Fuel, Gas, Water / Steam
• 20 milliseconds response time to temperature • Hydraulic or Pneumatic Systems
changes
• Foams and Pastes
• Pressure range to 4,000 psi
• Cryogenic Materials
• Temperature range from -320 to 1,250 degrees
Fahrenheit • Heat Transfer and Superheaters
• All stainless steel fittings with other materials • Plastics
available
• Any tube or pipeline where accurate
• Sizes from 1/4 to two inches are available temperature measurement is required

Sanitary design available - Contact Factory

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 69


Flow-Thru Thermocouples & RTDs
D3 Series

Flow-Thru temperature sensors use either the Nanmac


Right-Angle Ribbon Thermocouple or a Pt100 ohm RTD.
The Right-Angle Ribbon Thermocouple utilizes a special
ribbon element which eliminates conduction errors,
typically caused by shallow immersion in the flowing gas
or liquid within the pipeline. Additionally, this ribbon design
also provides response times in the low milliseconds.

All Pt100 RTD devices are of sanitary design as


the sensor is separated from the material within the
pipeline by a 0.015 inch thick stainless steel diaphragm.
Thermocouples requiring sanitary design are also
available by adding the diaphragm to the thermocouple.
NOTES:
• Temperature range: -320 to 1,250 degrees • Termination is 1/4 inch OD stainless steel
Fahrenheit tube with standard size male plug attached.
• Pressure range: 0 to 4,000 psi • Other termination styles are available
upon request; i.e. transition to flex leads,
• Response time: 20 milliseconds to transient explosion proof connector heads, etc.
temperature changes
• RTD units are available upon request
• Thermal junction: exposed Right-Angle
Ribbon • Special designs having ports of different
dimensions are also available
• Union type: stainless steel flared tube union,
furnished without tube nuts
• Thermocouple Types: E, J, K & T

All units come standard with junction flush to


inner wall surface. If junction is to protrude into
the stream, specify dimension “E” up to 1/4 inch.

Tolerance on “E” is 0.015 inch.

Example: D3-4-K-E = 1/16

Specifications
Tube Size Thread Size Hex Approximate Length Maximum
Part No.
(D) (T) (H) (L) Pressure
D3-4 1/4 7/16 - 20 7/8 1.7 4,000
D3-6 3/8 9/16 - 18 7/8 1.8 4,000
D3-8 1/2 3/4 - 16 7/8 2.0 3,000
D3-10 5/8 7/8 - 14 13/16 2.2 3,000
D3-12 3/4 1-1/16 - 12 1-1/8 2.6 3,000
D3-16 1 1-5/16 - 12 1-3/8 2.7 2,000

70 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Flow-Thru Thermocouples & RTDs
Compression Fitting Tube Unions
D4 Series

Our Flow-Thru Thermocouples and RTDs use


either a right-angle ribbon thermocouple sensor or a
Pt100 Ohm RTD. Utilizing a special ribbon element
which eliminates conduction errors due to shallow
immersion into the flowing gas or liquid within the
pipeline. Additionally, this ribbon design provides
response times within the low milliseconds. All
Pt100 RTD devices are sanitary since the sensor
is separated from the material in the pipeline by a
0.015 inch thick stainless steel diaphragm. For
thermocouples requiring sanitary designs contact
the factory.
D
NOTES:
• Temperature Range: -320 to 1,250 degrees • Termination: 3/8 inch OD stainless steel tube
Fahrenheit with standard size 2 pin male plug attached.
• Pressures up to 4,000psi • Termination Styles: Transition to Flex Leads,
Explosion Proof Connector Head, 3 or 4
• Response Times: Thermocouples (20ms) wire RTD, Flexible Lead Wire, etc. (contact
and RTDs (3s) factory)
• Available Types: Thermocouples (J, K, E & • Union Type: 316 stainless steel compression
T) and RTDs (Pt100 2 wire standard) tube union

RTDs come standard with


diaphragm. Thermocouples with
a diaphragm are available upon
request for sanitary applications

Specifications
Part No. T (diameter) A (in.)
D4-80 1/4 2.14
D4-81 5/16 2.34
D4-82 3/8 2.40
D4-83 1/2 2.76
D4-84 5/8 2.92
D4-85 3/4 3.02
D4-86 1 3.58

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 71


Flow-Thru Thermocouples & RTDs
Male and Female NPT Unions
D4A Series
Our Flow-Thru Thermocouples and RTDs use either a right-
angle ribbon thermocouple sensor or a Pt100 Ohm RTD.
Utilizing a special ribbon element which eliminates conduction
errors due to shallow immersion into the flowing gas or liquid
within the pipeline. Additionally, this ribbon design provides
response times within the low milliseconds. All Pt100 RTD
devices are sanitary since the sensor is separated from the
material in the pipeline by a 0.015 inch thick stainless steel
diaphragm. For thermocouples requiring sanitary designs
contact the factory.

NOTES:
• Temperature Range: -320 to 1,250 degrees • Termination: 3/8 inch OD stainless steel tube
Fahrenheit with standard size 2 pin male plug attached.
• Pressures up to 4,000psi • Termination Styles: Transition to Flex Leads,
Explosion Proof Connector Head, 3 or 4
• Response Times: Thermocouples (20ms) wire RTD, Flexible Lead Wire, etc. (contact
and RTDs (3s) factory)
• Available Types: Thermocouples (J, K, E & • Union Type: 316 stainless steel compression
T) and RTDs (Pt100 2 wire standard) tube union

Male Female
RTDs come
standard with
diaphragm.
Thermocouples
with a diaphragm
are available upon
request.

Specifications
Male Female Maximum (psi)
Part No. Pipe Size
Dm Hm Am Df Hf Af Male Female
D4A-4 1/8 3/16 7/16 1-7/32 11/32 9/16 13/16 4,000 4,000
D4A-6 1/4 9/32 9/16 1-19/32 7/16 3/4 1-1/8 4,000 4,000
D4A-8 3/8 3/8 11/16 1-5/8 37/64 7/8 1-1/4 4,000 3,500
D4A-10 1/2 15/32 7/8 2 23/32 1-1/16 1-1/2 4,000 3,500
D4A-12 3/4 5/8 1-1/16 2 59/64 1-1/4 1-9/16 4,000 3,500
D4A-16 1 7/8 1-3/8 2-1/4 1-1/64 1-5/8 2 4,000 3,000
D4A-20 1-1/4 1-3/32 1-3/4 1-13/32 1-1/2 2-1/8 2-3/8 3,000 2,000
D4A-24 1-1/2 1-11/32 2-1/8 1-21/32 1-3/4 2-3/8 2-5/8 2,500 1,000
D4A-32 2 1-13/16 2-3/4 1-29/32 2-7/8 2-7/8 2-5/8 2,500 1,000

72 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Hose Clamp Thermocouples
D6 Series

Our line of hose clamp thermocouples


consists of three basic styles:

Style 1: Has an 1/8 inch OD by six inches long stainless


steel sheath. The thermocouple wires inside the sheath
are insulated with a high temperature mineral oxide
insulation. Standard units have a grounded junction
which is brazed to the stainless steel pipe clamp. Two
versions of the attachment are available: i.e. tangential
and perpendicular. Unless otherwise specified, we will
furnish the tangential style (shown). The perpendicular
style is available upon request at no additional cost.
The style 1 units have five feet of fiberglass insulated
extension wire connected to the stainless steel sheath.
D
Style 2: Is the same as style 1, except the stainless
steel sheath is deleted. The fiberglass insulated
thermocouple wires are welded directly to the stainless
steel pipe clamp.

Style 3: Is the same as style 2, except the fiberglass


insulated thermocouple wires have a stainless
steel overbraid which reduces stray, unwanted
electromagnetic pickup and increases lead wire
durability.
NOTES:
Specifications
• All units come with five feet of 20 gage
Style 1 Style 2 Style 3 fiberglass insulated extension leads, other
Pipe OD (in.) materials are available.
Part No. Part No. Part No.
7/32 → 5/8 D6-5 D6-52 D6-53 • All thermocouples are mounted in a
3/8 → 1/2 D6-6 D6-62 D6-63 tangential style as shown above, unless a
3/8 → 5/8 D6-8 D6-82 D6-83 perpendicular style is specified.
1/2 → 5/8 D6-10 D6-102 D6-103 • All thermocouples are grounded to hose
5/8 → 3/4 D6-12 D6-122 D6-123 clamp for fast response.
3/4 → 1 D6-16 D6-162 D6-163
1 → 1-1/4 D6-20 D6-202 D6-203 • All units are available in thermocouple
1-1/4 → 1-1/2 D6-24 D6-242 D6-243 calibration types E, J, K, N & T.
1-1/4 → 1-3/4 D6-28 D6-282 D6-283 • Various terminations are available, contact
1-1/2 → 2 D6-32 D6-322 D6-323 us.
1-3/4 → 2-1/4 D6-36 D6-362 D6-363
2-1/16 → 3 D6-40 D6-402 D6-403 • When ordering, specify part number and
2-5/16 → 3-1/4 D6-44 D6-442 D6-443 thermocouple type.
3 → 3-1/4 D6-52 D6-522 D6-523 Example: D6-5-J
3-1/4 → 3-1/2 D6-60 D6-602 D6-603 • To specify (U - ungrounded) junction add
4 → 4-1/2 D6-68 D6-682 D6-683 the suffix “U” to the part number.
4-1/16 → 5 D6-72 D6-722 D6-723
4-5/8 → 5-1/2 D6-80 D6-802 D6-803 • To specify (P - perpendicular) style versus
5-1/8 → 6 D6-88 D6-882 D6-883 tangential add suffix “P” to the part number.
5-7/8 → 6-3/4 D6-104 D6-1042 D6-104

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 73


Economical Pipe-Line Thermocouples & RTDs
Simple Installation Into Pipelines
D7 Series

NOTES:
• Conventional thermocouple with stainless
steel sheaths and grounded junctions
• Available in thermocouple calibration
types: E, J, K, N & T
• Also available with Pt100 ohm RTD
• Temperature range to 500 degrees
Fahrenheit
• Pressure range to 500 psi
• Sensing junction immersed 1/3 diameter
into stream

Stainless Steel Union

Specifications
Part No. Tube OD (D) Hex (H) Length (L)
D7-4T-(•)-(*) 1/4 9/16 2.12
D7-5T-(•)-(*) 5/16 5/8 2.34
D7-6T-(•)-(*) 3/8 11/16 2.40
D7-8T-(•)-(*) 1/2 7/8 2.84
D7-10T-(•)-(*) 5/8 1.0 3.06
D7-12T-(•)-(*) 3/4 1-1/8 3.14
D7-16T-(•)-(*) 1.0 1-1/2 3.86

74 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Surface and In-Wall Thermocouples
with “Self-Renewing” Junctions
E6 Series
A dramatic innovation in thermocouple design,
the patented Self-Renewing Thermocouple
provides temperature data never before available.
This innovative design puts the thermocouple
junction exactly at the 2-dimensional end surface
of the probe. It can be machined to most any shape, erode or wear away up to 1/2 inch
during the process and continuously renew it’s own junction while being eroded. Response
times are in the very low millisecond range and designed to measure temperatures at the
surface of a wall or chamber.

These thermocouples are made with stainless steel housings. The useful range of the
thermocouple element inside may exceed the melting point of stainless steel (2,550 degrees
Fahrenheit). Therefore, we suggest you contact one of our engineers with the unique details
and use for temperatures expected to be above this range.
Modification & customization is almost limitless on this device - Contact Factory

E6-10 Series E6-20 Series E6-30 Series E6-40 Series


E

Specifications
Maximum Pressure
Part No. Thread Size
(psi)
E6-10 5,000 10 NF x 1/2”
E6-20 25,000 3/8 - 24 NF x 1/2”
E6-30 25,000 1/2 - 20 NF x 3/4”
E6-40 25,000 1/2 - 20 NF x 3/4”

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 75


Self-Renewing Thermocouple
Reference
E11 Info

Surface Temperature Measurements


Used as a surface thermocouple, the Nanmac Self-Renewing
Thermocouple will measure the precise temperature of the hot
surface without obstructing the flow pattern. The probe can
be made of most any metal. Thus, matching the properties of
the test wall and reducing the thermal conductivity errors to a
minimum. As the surface of the wall (if subjected to erosion)
wears away; the probe will continuously measure the surface
temperature even while the probe itself erodes or wears away
(up to 1/2 an inch during this process).

In-Wall Temperature
Used as an in-wall temperature measuring probe, the Nanmac Self-Renewing Thermocouple
can be positioned to an accuracy of better than ±0.001 inches. This feature, together with
the fast response times of this probe make it an ideal in-wall thermocouple.

Immersion Temperature
Under certain applications the Nanmac Self-Renewing Thermocouple can be used for
immersion applications such as within the stream of flowing plastic or high velocity gases. It
is however recommended that Nanmac engineers should be consulted for the thermocouple
design best suited for immersion.

Highly customizable in design and material -


contact factory with your unique requirements

NOTES:
• 20 milliseconds response time to transient
temperatures
• Thermocouple junction renewable by filing or
sanding the probe tip.
• Two-dimensional thermal junction for accurate
positioning of the sensing tip.
• Temperature range up to 4,000 degrees
Fahrenheit
• Pressure range up to 10,000 psi
• Probe diameters 1/8” OD and up
• Probe housing material fabricated from any
machinable material.
• Sensing tip can be machined to match any
desired shape.

76 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Self-Renewing Thermocouples
E12 Series

An innovation in thermocouple design this patented


Self-Renewing Thermocouple provides temperature data
never before available. This innovative design puts the
thermocouple junction exactly at the end of the probe. It
can be machined to most any shape, erode or wear away
up to 1/2 inch during the process and continuously renew
it’s own junction while being eroded.

NOTES:
• Includes a stainless steel adjustable
compression fitting with 1/8 NPT threads
(3/8 inch OD probes use a 1/4 inch NPT • All Tantalum units are thermally ungrounded
fitting). and require construction that utilizes a
union to join the thermocouple probe to the
• Other size NPT or O-Ring fittings are stainless steel sheathed leads (stem).
available.
• A standard thermocouple plug is attached
to all units (female connectors are supplied).

Specifications
Material and Dimensions (in.)
Part No.
A B C D
* Tantalum requires slight
E12-1 SS 304 0.250 4 0.125
design modifications - contact E12-2 SS 304 0.187 4 0.125
factory for specifics E12-3 SS 304 0.125 4 0.063
E12-4 SS 304 0.375 4 0.125
* E12-5A Tantalum 0.250 4 0.125
E12-8 Inconel 0.250 4 0.125
E12-9 Copper 0.250 4 0.125

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 77


Multi-Function Sensor
Reference
E13 Info

The Multi-Function Sensor (MFS) consists


of your specified number of Nanmac Eroding
Thermocouples capable of recording temperatures
even while subjected to ablation, char, and erosion
(for up to 1/2 inch of each installed thermocouple).
The thermal junctions are two-dimensional and
are located at given depths within the MFS with a
precision of ±0.001 inch. The entire gauge and
housing is fabricated from the same material as that under study (whether it be an ablative
or non-ablative plastic, metal, or non-metal). Thereby, eliminating errors due to differences
in thermal and physical properties. A multitude of shapes and sizes can be made to fit
any requirement. Typical materials used include various phenolic, graphite, glass laminates,
graphite/phenolic composites, copper, steel, molybdenum, and tungsten.

We invite inquiries on special thermocouples and gauges for your particular


application. We have designed and built units with multiple thermocouple
junctions, extremely high sensitivity, combination metal and plastic sensing tip,
and a wide variety of dimensional changes.

NOTES:
Example of Custom Design
• Gauge material same as test item for
minimum heat, char, erosion, and ablation
variations
• Two-dimensional accuracy at the point of
measurement
• Fast response times
• Temperature ranges to 5,000 degrees
Fahrenheit
• Pressure range to 3,000 psi
Applications:
• Material research and evaluation
• Insulation and char characteristics
• Rocket insulation and re-entry shields
• Temperature monitoring and control of
cooling apparatus
• Ablation, erosion and char rates
• Heat transfer and fusion point temperature of
materials
• Automotive brake band research

78 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Standard 2-Pole & 3-Pole Connectors
F2 Series

Prongs and inserts match thermocouple


calibrations to maintain sensing accuracy.
Alloy and polarity are identified by
symbols molded into body. Molded from
a glass filled thermoset compound for
high strength, these connectors are color
coded to thermocouple calibration and
can be used in ambient temperatures
of a continuous 400 degrees Fahrenheit and an intermittent 500 degrees Fahrenheit.
High temperature connectors are all color coded ‘Red’ with an ambient temperature of a
continuous 800 degrees Fahrenheit and an intermittent 1,000 degrees Fahrenheit. Inserts
have a spring loaded collet assuring full positive contact. The negative insert is larger
preventing mismatching.

Color Coded Body (400°F Series)

Specifications
Part No. Description
F2-1-(•) 2-Pole Plug, 400°F max.
F2-2-(•) 2-Pole Jack, 400°F max. • = Insert thermocouple calibration:
F2-3-(•) 2-Pole Plug, 800°F max.
F2-4-(•) 2-Pole Jack, 800°F max. B, C, CU, E, J, K, N, R, S, T
F2-5 (#) Tube Adaptor for 2-Pole Plug
F2-6 Cable Clamp for 2-Pole Jack
F2-7 (#) Dual Element for Tube Adaptor # = Specify sizes:
F2-8-(•) 3-Pole Plug, 400°F max. 0.062, 0.125, 0.187, 0.250, 0.375
F2-9-(•) 3-Pole Jack, 400°F max.
F2-10-(•) 3-Pole Plug, 800°F max.
F2-11-(•) 3-Pole Jack, 800°F max.
F2-12 (3) Tube Adaptor for 3-Pole Plug
F2-13 Cable Clamp for 3-Pole Jack

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 79


Miniature Plugs & Jacks
F3 Series

Our miniature plugs and jacks provide dependability.


Quick and easy installation of thermocouple wires and
sheaths. Accepting wire from 0.001” diameter to 20
gage. Polarized pins minimize mismatching of the large
double wipe jacket inserts assure tight grip and positive
contact. Rubber grommets are supplied with plugs and
jacks. Molded from a glass filled thermoset compound
for high strength.

These connectors are color coded to thermocouple calibration and can be used in
ambient temperatures of a continuous 400 degrees Fahrenheit and intermittent 500 degrees
Fahrenheit. High temperature connectors are color coded ‘Red.’ With ambient temperatures
of a continuous 800 degrees Fahrenheit and intermittent 1,000 degrees Fahrenheit.

Color Coded Body (400°F Series)

• = Insert thermocouple calibration: Specifications


B, C, CU, E, J, K, N, R, S, T Part No. Description
F3-1-(•) Plug, 400°F max.
F3-2-(•) Jack, 400°F max.
# = Specify sizes: F3-3-(•) Plug, 800°F max.
0.062, 0.125 F3-4-(•) Jack, 800°F max.
F3-5 Mini Cable Clamp
F3-7-(#) Crimp Adaptor

80 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Circuit Boxes
F4 Series

The standard jack Circuit Box is available from


one to six jacks and in two materials. Standard
material jacks are good to 400 degrees
Fahrenheit. High temperature jacks are good to
800 degrees Fahrenheit. All high temperature
jacks are color coded ‘red.’ All standard jacks
are coded per thermocouple calibration.

The miniature jack Circuit Box (not shown)


is available with two from to six jacks. All jacks
are marked with thermocouple calibration, color
coded and numbered. These jacks are good to
400 degrees Fahrenheit.

NOTES:
• Available in thermocouple calibration types:
E, CU, CX, J, K, N, SX & T
• Specify thermocouple calibration when
ordering.
Example: F4-7-K F

Specifications
Part No. Description
F4-4 Mini Jack Circuit Box, 2 Jacks
F4-5 Mini Jack Circuit Box, 3 Jacks For 800°F
F4-6 Mini Jack Circuit Box, 4 Jacks jacks, add
F4-7 Mini Jack Circuit Box, 5 Jacks suffix “-HT”
F4-8 Mini Jack Circuit Box, 6 Jacks
F4-9 Standard Jack Circuit Box, 400°F max. 1 Jack
F4-10 Standard Jack Circuit Box, 400°F max. 2 Jacks
F4-11 Standard Jack Circuit Box, 400°F max. 3 Jacks
F4-12 Standard Jack Circuit Box, 400°F max. 4 Jacks
F4-13 Standard Jack Circuit Box, 400°F max. 5 Jacks
F4-14 Standard Jack Circuit Box, 400°F max. 6 Jacks
F4-15 Standard Jack Circuit Box, 800°F max. 1 Jack
F4-16 Standard Jack Circuit Box, 800°F max. 2 Jack
F4-17 Standard Jack Circuit Box, 800°F max. 3 Jack
F4-18 Standard Jack Circuit Box, 800°F max. 4 Jack
F4-19 Standard Jack Circuit Box, 800°F max. 5 Jack
F4-20 Standard Jack Circuit Box, 800°F max. 6 Jack

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 81


Conduit Heads
F6 Info

Miniature Weatherproof (MW) heads can be either


Miniature Weatherproof (MW) Head 1/4 inch or 3/8 inch and are designed for termination
of single/dual thermocouples or RTDs. The probe
mount and wire entrance threads are 1/4 inch NPT.
Cover includes gasket to seal against moisture and
chain to prevent loss. Molded of reinforced thermoset
compound, this connector head can be used in
ambient temperatures to 350 degrees Fahrenheit
(175 degrees Celsius). This MW design requires no
General Purpose (GP) Head separate terminal block because a terminal strip is
molded into the connector head (terminal screws
are provided).

General purpose (GP) heads are rugged cast


aluminum, stainless steel, or plastic units with
various NPT probed connection sizes and the
choice of terminal block to fit your application. Flip
Weatherproof (WP) Head
top versions are also available.

Weatherproof (WP) heads are rugged cast


aluminum or cast iron screw cover units that are
available in various NPT probe connection sizes and
terminal clock to fit your application.

Explosion Purpose (EP) Head


Explosion Proof & Atex (EP) heads are cast
aluminum or stainless steel, screw cover units that
comply with NEC & after rating and are designed
for use in hazardous environments where extreme
caution must be observed. Internal threaded holes
accommodate four wire terminal blocks. Mating
terminal blocks are available.

All these conduit heads except the MW models, require an


internal terminal block (see our F7 series)

82 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Conduit Heads
General Purpose
F7-1 Series

General purpose (GP) heads


are rugged cast aluminum,
stainless steel, or plastic units
with various NPT probed
connection sizes and the choice
of terminal block to fit your
application. Flip top versions
are also available.

NOTES:
• Utilizes DIN Transmitters and fits most terminal blocks. • Rated NEMA 4x & IP68

Aluminum & Stainless Steel Polypropylene

Specifications
Thread Size
Part No. Material
(PE x CE)
F7-1-1212-AL 1/2” x 1/2” NPT
F7-1-1234-AL Aluminum 1/2” x 3/4” NPT
F7-1-3434-AL 3/4” x 3/4” NPT
Our polypropylene heads are FDA approved and
F7-1-1212-SS 1/2” x 1/2” NPT
can be used for sanitary applications.
F7-1-1234-SS Stainless Steel 1/2” x 3/4” NPT
F7-1-3434-SS 3/4” x 3/4” NPT
F7-1-1212-PP 1/2” x 1/2” NPT
F7-1-1234-PP Polypropylene 1/2” x 3/4” NPT
F7-1-3434-PP 3/4” x 3/4” NPT

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 83


Conduit Heads
Weatherproof (WP)
F7-12 Series

Weatherproof (WP) heads are rugged cast aluminum


or cast iron screw cover units that are available in
various NPT probe connection sizes and terminal clock
to fit your application.

NOTES:
• Can accomodate standard DIN Transmitters and fits
most termnial blocks.
• Rated NEMA 4x & IP68

Specifications
Thread Size
Part No. Material
(P x C)
F7-12-1212-CI 1/2” x 1/2” NPT
F7-12-1234-CI Cast Iron 1/2” x 3/4” NPT
F7-12-3434-CI 3/4” x 3/4” NPT
F7-12-1212-AL 1/2” x 1/2” NPT
F7-12-1234-AL Aluminum 1/2” x 3/4” NPT
F7-12-3434-AL 3/4” x 3/4” NPT

84 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Conduit Heads
Flip Top
F7-23 Series

The Nanmac F7-23 Series Conduit Heads are


rugged aluminum units with various NPT probe
connection sizes and the choice of terminal block
to fit your application. Most housings come with
screw top caps, the flip top of the F7-23 allows for
quick opening and closing of the top utilizing the
clip and latch configuration.
NOTES:
• Flip top with snaplock
• Quick and easy access

Specifications
Thread Size
Part No. Material
(P x C)
F7-23-1212-AL 1/2” x 1/2” NPT
F7-23-1234-AL Aluminum 1/2” x 3/4” NPT
F7-23-3434-AL 3/4” x 3/4” NPT

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 85


Conduit Heads
Miniature Weatherproof (MW)
F7-24 Series

Miniature Weatherproof (MW) heads can have


either 1/4 inch or 3/8 inch process connection
and are designed for termination of single/dual
thermocouples or RTDs. The probe mount and
wire entrance threads are 1/4 inch NPT. Cover
includes gasket to seal against moisture and chain
to prevent loss. Molded of reinforced thermoset
compound, this connector head can be used in
ambient temperatures to 350 degrees Fahrenheit
(175 degrees Celsius). This MW design requires
no separate terminal block because a terminal
strip is molded into the connector head (terminal
screws are provided).

Miniature Weatherproof (MW)

Specifications
Part No. Description Probe Mount Thread
F7-24-1414-RTC 1/4” NPT
Standard 350°F
F7-24-3814-RTC 3/8” NPT
F7-24-1414-RTCHT 1/4” NPT
Hi-Temp 800°F
F7-24-3814-RTCHT 3/8” NPT

86 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Terminal Blocks
for Conduit Heads
F7-4 Series

Terminal blocks are designed to connect temperature probes to existing extension cables.
They fit in a wide variety of sensor housings which include: aluminum, stainless steel, plastic
heads, etc. These terminal blocks may be available in various shapes (round, oval, hex) and
can provide 1, 2, 3, or 4 sets of poles to meet your specific installation requirements.

NOTES:
• Designed for: Single, Duplex, and Triplex
• Al2O3 - 45% Stronger than ceramic, resistant temperature sensors.
to cracking and flaking
• Other terminal blocks available upon
• Also available in Bakelite request, contact factory

F7-4-1 F7-4-1-DPX

F
F7-4-1-TRX F7-4-1-RTC

Specifications
Number
Part No. Material Shape
of Terminals
F7-4-1 Alumina Round 4
F7-4-1-DPX Alumina Round 4
F7-4-1-TRX Alumina Round 6
F7-4-1-RTC Bakelite Round 3
F7-4-2 Alumina Oval 2

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 87


Conduit Heads
Explosion Proof (EP) & Atex Approved (ATEX)
F7-8 & F7-9 Series

Explosion Proof (EP) & Atex Approved (ATEX) heads


are available in cast aluminum or stainless steel, screw
cover units. These units are rated for use in hazardous
environments where extreme caution must be observed.
Internal threaded holes accommodate four wire terminal
blocks. Various terminal blocks are available.
Explosion Proof Zone Approval:
• Class I, Div 1, Group B, C & D
• Class II, Div 1, Groups E, F & G
• NEMA 4x, Type 4
• ATEX: Ex d 11C T6 IP68
• ATEX: Ex tD A21 T100°C IP68

Specifications
Order
Part No. Material Epoxy Color Thread Sizes (P x C)
Certification
F7-8-1212-AL 1/2” x 1/2” NPT
F7-8-1234-AL Aluminum Blue ATEX 1/2” x 3/4” NPT
F7-8-3434-AL 3/4” x 3/4” NPT
F7-8-1212-SS 1/2” x 1/2” NPT
F7-8-1234-SS SS316 - ATEX 1/2” x 3/4” NPT
F7-8-3434-SS 3/4” x 3/4” NPT
F7-9-1212-AL 1/2” x 1/2” NPT
F7-9-1234-AL Aluminum Silver FM & CSA 1/2” x 3/4” NPT
F7-9-3434-AL 3/4” x 3/4” NPT
F7-9-1212-SS 1/2” x 1/2” NPT
F7-9-1234-SS SS316 - FM & CSA 1/2” x 3/4” NPT
F7-9-3434-SS 3/4” x 3/4” NPT

88 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Canister Heads
F7-8380 Series

The Nanmac F7-8380 Series Canister Heads


are small nickel-plated steel enclosures
designed for applications where space is
limited. These canister heads can be provided
with 2, 3, or 4 terminals for both thermocouples
and RTDs, up to #20 gauge (0.032 inch
diameter) wire.

These units come equipped with an O-ring


NOTES:
moisture seal and a neoprene cap grommet to
help prevent water ingress. The F7-8380 Series • O-Ring Seal
comes with either, 1/4 or 1/8 inch NPT opening. • 2, 3, or 4 Terminal
• Neoprene cap grommet comes standard
• Up to #20 gauge (0.032 inch) wire.

Specifications
Number
Part No. Material Description Process Opening
of Terminals
F7-8380-2-18 Nickel-Plated 1/8” NPT
2 Canister Head
F7- 8380-2-14 Steel 1/4” NPT
F7- 8380-3-18 Nickel-Plated 1/8” NPT
3 Canister Head
F7- 8380-3-14 Steel 1/4” NPT
F7- 8380-4-18 Nickel-Plated 1/8” NPT
4 Canister Head
F7- 8380-4-14 Steel 1/4” NPT

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 89


Head Mount Digital Displays
with 4-20 mAmp Transmitter Installed
F7-LCD Series

The F7-LCD is a head mounted digital indicator,


including a non-isolated F11-40 Temperature Transmitter.
Both the LCD display and the temperature transmitter are
installed within an aluminum general purpose connector
head. The connector head has a polycarbonate viewing
window. The indicator has 1/2 inch high-contrast LCD
digits. The connector head has 1/2 NPT process threads
and 3/4 NPT conduit connection. Both NPT dimensions
can be reduced to accommodate your requirement.
Temperature transmitter programming performed by
Nanmac Corporation.

User Specified Information


(programmed by NANMAC)
Indicator Specifications
1) Input Sensor Type
Display High Contrast, Four-Digit LCD
2) Cold Junction
(thermocouple only, default is 32°F / 0°C)
Digit Display 4 (0.5 inch high) digits including
Height minus sign; ~ 0.5 inch (12mm)
3) Temperature Scale °F or °C
Operating
-20 to 70°C (-4 to 158°F)
4) Temperature Range Temperature
(full sensor range as default)
Typical
5) Sensor Break Detection ±0.1% of programmed span ± digit
(upscale or downscale - upscale is default)
Accuracy

90 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Heavy Duty Head Mount Indicators
with 4-20 mAmp Transmitter Installed
F7-LCD-SP Series

The F7-LCD-SP indicator is a heavy-duty LCD indicator


installed within a NEMA 4 housing and includes an
isolated, EX rated temperature transmitter with 4-20
mAmp output.

Designed for field mounting, it utilizes a rugged,


IP66 / NEMA 4 splash proof housing.

All programming of the installed temperature


transmitter is done at the factory. The user simply
connects the required loop power (see F11-50 for full
specifications).

The actual transmitter used for this requirement is the


F11-50 series, except it has EX rating. Temperature
ranges and input loop power requirements are the
same. For general use requirements that do not need User Specified information
isolated inputs, EX rating and NEMA enclosures, please (programmed by Nanmac)
see the F7-LCD device. 1) Input Sensor Type

2) Cold Junction (Tc only, default is


32°F / 0°C) F
3) Temperature Scale °F or °C

4) Temperature Range (Full Sensor


General Specifications Range as default)
Conduit Connection 3/4 NPT, top and bottom
5) Sensor Break Detection -
Mounting Wall mount or NPT connection
upscale or downscale
Casing Material Cast aluminum, powder-coat epoxy paint (default is upscale).

Indicator Specifications
Display Black LCD w/4 digits including (-) sign
Digital Height ~ 0.5” (12mm)
Range Any range between (-) 1999 to 9999, 0 to 3 decimals
Under / Over Range Indicator Flashing Lo/Hi
Reponse Time Approximately 0.5s
Ambient operating temperature -25 to +70°C / -13 to +160°F
Accuracy +/-0.05% full scale +/- 1 digital, typical
Protection IP 66 / NEMA 4
Wiring Connection Stranded, < 16 AWG

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 91


Conduit Heads
Explosion Proof (EP)
F7-NEMA-WINDOW Series

This Explosion Proof (EP) instrument housing


accommodates large diameter assemblies, multi-level
circuit boards, and/or wide angle readouts and displays.
Providing maximum clearance to facilitate instrument
mounting, calibration, or service. Precision machined
from sand-cast, copper-free aluminum.

This housing is used for mounting the F11-40 or F11-


50 Series Transmitters. See our fully assembled and
functional F7-LCD-SP which utilizes this head.

NOTES:
• Two 3/4” NPT conduit Feed-Thru hubs offset for
maximum clearance and capacity.
• 7/16” thick base for blind tapped instrument mounting
holes in any location.
• Glass cover models have a large 2.5” diameter,
tempered glass window for local read out.
• Corrosion resistant, “safety blue” polyester
powder coating.

Specifications
Input Current 4-20 mA
Maximum Current 30 mA
Maximum Current ~3.5 mA
for Operation
Voltage Drop ~1.5 V
Indication
Display Black LCD with 4 digits including minus sign
Digit Height 12.7 mm/0.5”
Indication Range Any range between - 1999 to 9999
Decimals Selectable, 0 to 3
Upper Range / Over Range Flashing symbols LO/HI
Engineering Units Set of Labels included (including blanks)
Response Time Approximately 0.5 seconds
Scale Setting Two pushbuttons inside the housing
Operation Temperature -25 to +70°C / -13 to +158°F
Typical Accuracy ±0.05 % FS ±1 digit
Protection IP66 / NEMA 4
Connections Stranded, ≤ 1.5 mm2 AWG 16
Conduit Threads 2 x 3/4” NPT
Mounting Wall Mounting

92 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Jack Panels
F8 Series

Available in two materials, the standard material is good to 400 degrees Fahrenheit. The
high temperature material is good to 800 degrees Fahrenheit. All high temperature jacks
are color coded ‘red.’ All standard jacks are coded per thermocouple calibration. Standard
thermocouple calibration symbols and color codes are easily visible from the front.

NOTES:
• All panels are 3/32 inch steel frame.
• All thermocouple calibrations and copper jacks are available.
• For 800°F units, add suffix “-HT” for High Temperature, to the part
number. F
• Numbering sequence begins at 1 unless otherwise noted.
• Special panels with up to 240 circuits are available, contact factory.
• When ordering, specify part number and calibration.
Example: F8-2-K

Specifications

Number Panel Cutout


Part No. Jack Size
of Jacks Height (in.) Width (in.)
F8-1 2 1-1/2 1-1/2
F8-2 3 1-1/2 2-1/4
F8-3 Standard 4 1-1/2 3
F8-4 5 1-1/2 3-3/4
F8-5 6 1-1/2 4-1/2
F8-6 6 1 3-7/8
F8-7 12 1 7-5/8
Mini
F8-8 18 1 11-3/8
F8-9* 24 2-1/2 7-5/8

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 93


Thermocouple Reference Junctions
F11 Series

This miniature full bridge (MF) compensator


provides stable and accurate secondary
thermocouple junctions. This module
eliminates the need for ice bath or
electromechanical devices by simulating
the desired secondary reference point
temperature (0 degrees Celsius is standard).
This unit is externally energized by a 5.0 VDC.
Other voltages upon request; power supply is
not included.

They have a low impedance reference source. Compatible with computer and process
controllers. All incorporating the characteristics of high accuracy, small size, low
power, instant operation, and rugged construction. This compensator is available with
soldered terminals for power and output signal and leads for thermocouple input with 2
mounting holes.

Specifications
Ordering Information
0.25°C @ 25°C ambient
Part No. Type 0.5°C @ 50°C ambient
Accuracy
0.75°C @ 75°C ambient
F11-7 J 1.0°C @ 100°C ambient
F11-8 K
F11-9 T Stability Better than 0.25°C at stabilized ambient between -54°C to 100°C
F11-10 R Reference Point 0°C standard
F11-11 S
F11-12 E Size 1” x 1” x 5/16” thick
F11-13 G Weight 10 grams
F11-14 C
F11-15 D Input Power 5 VDC standard
F11-16 B Power Consumption As low as 100 microwatts
Mounting (2) #6 screws

94 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Head Mount Transmitters
Standard
F11-40 Series

The F11-40 series is a basic, non-isolated, easy-to-use


two-wire transmitter for in-head mounting in DIN B and
similar heads. Reduced height simplifies mounting in low
profile connection heads. Needing no external power
supply other than your LOOP power, the F11-40 can be
used for three or four wire RTDs; as well as, thermocouple
calibration types B, C (W5), E, J, K, N, R, S & T.

Thermocouple input cold junction compensation (CJC)


is fully automatic by means of an accurate measurement
of the terminal temperature. Alternatively, the CJC can be NOTES:
disabled upon request. Also available are head mount • Accepts RTD in three and
four wire connection and 11
enclosures with digital displays. Either regular duty or thermocouple types
heavy duty, NEMA rated head mount displays. • NAMUR compliant
Connections Inputs / Outputs • Easy wiring, robust terminals
and large center hole
• Rugged design tested for 5g
vibrations

Dimensions

Temperature Ranges and Specifications


Pt100 (a=0.00385) -200 to 1000°C / -328 to 1832°F
Pt1000 (a=0.00385) -200 to 200°C / -328 to 392°F
PtX10 ≤X≤ 1000 (a=0.00385) Upper Range Depending on X-Value User Specified Information
Input RTD
Pt100 (a=0.003902) -200 to 1000°C / -328 to 1832°F (programmed by NANMAC)
3-,4-wire connection
Pt100 (a=0.003916) -200 to 1000°C / -328 to 1832°F
Ni100 (1) -60 to 250°C / -76 to 482°F
1) Input Sensor Type
Ni1000 (1) -10 to 150°C / 14 to 302°F
2) Cold Junction
Input Thermocouples Types: B, C, E, J, K, N, R, S, T (thermocouple only, default is
32°F / 0°C)
Sensor Failure Upscale, Downscale or Off
3) Temperature Scale °F or °C
Adjustments - Zero Any Value Within Range Limits
4) Temperature Range
Minimum Spans 100° either F or C
(full sensor range as default)
Output 4-20 Temperature Linear
5) Sensor Break Detection
Operating Temperature -40 to 85°C / -40 to 185°F (upscale or downscale - upscale
is default)
Galvanic Isolation No
Power Supply 8 to 36 VDC
Typical Accuracy ±0.15% of Temperature Span
Connection Head DIN B or Larger

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 95


Rail Mount Transmitters
Standard
F11-40RM Series

The F11-40RM series is a basic, non-isolated, easy-to-use two-wire


transmitter. Needing no external power supply other than your LOOP
power, the F11-40RM can be used for three or four wire RTDs; as well
as, thermocouple calibration types B, C (W5), E, J, K, N, R, S & T.

Thermocouple input cold junction compensation (CJC) is fully


automatic by means of an accurate measurement of the terminal
temperature. Alternatively, the CJC can be disabled upon request.
Also available are head mount enclosures with digital displays. Either
regular duty or heavy duty, NEMA rated head mount displays.

Dimensions Inputs / Outputs


NOTES:
• Accepts RTD in
three and four wire
connection and 11
thermocouple types
• NAMUR compliant
• This non-isolated
device should not be
used with multiple
grounded junction
thermocouples when
signals are input
into each of their
own transmitter. All
signals are input
into the same data
acquisition system. Temperature Ranges and Specifications
• Typical span is full Pt100 (a=0.00385) -200 to 1000°C / -328 to 1832°F
range of sensor, can Pt1000 (a=0.00385) -200 to 200°C / -328 to 392°F
be programmed for PtX10 ≤X≤ 1000 (a=0.00385) Upper Range Depending on X-Value
Input RTD
special ranges. 3-,4-wire connection
Pt100 (a=0.003902) -200 to 1000°C / -328 to 1832°F
Example: 100-500 Pt100 (a=0.003916) -200 to 1000°C / -328 to 1832°F
degrees Fahrenheit Ni100 (1) -60 to 250°C / -76 to 482°F
Ni1000 (1) -10 to 150°C / 14 to 302°F
User Specified Information Input Thermocouples Types: B, C, E, J, K, N, R, S, T
(programmed by NANMAC)
Sensor Failure Upscale, Downscale or Off
1) Input Sensor Type Adjustments - Zero Any Value Within Range Limits - Refresh Rate
2) Cold Junction Minimum Spans 100° either F or C
(thermocouple only, default is
32°F / 0°C) Output 4-20 Temperature Linear
3) Temperature Scale °F or °C Operating Temperature -20 to 70°C / -4 to 158°F
4) Temperature Range Galvanic Isolation No
(full sensor range as default)
Power Supply 8 to 36 VDC
5) Sensor Break Detection
(upscale or downscale - upscale Typical Accuracy ±0.15% of Temperature Span
is default)
Connection Head Rail acc. to DIN EN50022, 35mm

96 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Head Mount Transmitters
Isolated
F11-50 Series

The F11-50 is a universal, isolated two-wire transmitter. Used for


temperature and other measurement applications, it combines
competitive functionally and simple configuration. This device
is also available with these special ratings: FM, ATEX, and HART
communication. Contact us for your specific requirement. All
user specified information is programmed by Nanmac.

Dimensions Input Connections

Special Ratings:
• For FM approved
device, add suffix “FM”
to the part number.
• For ATEX approved
device, add suffix
“ATEX” to the part
number.
Temperature Ranges and Specifications
• For HART compatible
communications device,
F
Pt100 (a=0.00385) -200 to 1000°C / -328 to 1832°F
Pt1000 (a=0.00385) -200 to 200°C / -328 to 392°F add suffix “HART” to the
Input RTD
PtX10 ≤X≤ 1000 (a=0.00385) Upper Range Depending on X-Value part number.
Pt100 (a=0.003902) -200 to 1000°C / -328 to 1832°F
3-,4-wire connection
Pt100 (a=0.003916) -200 to 1000°C / -328 to 1832°F • For FM or ATEX plus
Ni100 (1) -60 to 250°C / -76 to 482°F HART communication
Ni1000 (1) -10 to 150°C / 14 to 302°F add suffix “FM” or
Input
“ATEX” plus “HART” to
Potentiometer 3-,4-wire connection, 0 - 2000 Ω the part number.
Resistance Example: F11-50-FM-
HART, or F11-50-ATEX-
Input Thermocouples Types: B, C, E, J, K, N, R, S, T HART
Input mV -10 to 500 mV
Sensor Failure User Definable Output
Adjustments - Zero Any Value Within Range Limits
Minimum Spans 100° either F or C User Specified Information
(programmed by NANMAC)
Output 4-20 / 20-4 mA, Temperature Linear
Operating Temperature -40 to 85°C / -40 to 185°F 1) Input Sensor Type

Galvanic Isolation 1500 VAC, 1 min. 2) Cold Junction


(thermocouple only, default is 32°F
F11-50: 6.5 to 36 VDC / 0°C)
Power Supply F11-50-FM: 8 to 30 VDC
3) Temperature Scale °F or °C
F11-50-ATEX: 8 to 30 VDC
4) Temperature Range
ATEX: II (1) G [EEx ia] IIC T4-T6 (full sensor range as default)
Intrinsic Satety
FM: Class I-III, Div. 1, Gr. A-G
5) Sensor Break Detection
Typical Accuracy ±0.1% of Temperature Span (upscale or downscale - upscale is
default)
Connection Head DIN B or Larger

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 97


Rail Mount Transmitters
Isolated
F11-50RM Series

The F11-50RM is a universal, isolated two-wire transmitter. Used for


temperature and other measurement applications, it combines competitive
functionally and simple configuration. Useful error correction functions
improve the accuracy. This device also has these special ratings: FM and
ATEX approved. All user specified information is programmed by Nanmac.
Accepts RTDs, thermocouples, mV, and Ω.

Dimensions Input Connections

Temperature Ranges and Specifications


Pt100 (a=0.00385) -200 to 1000°C / -328 to 1832°F
Pt1000 (a=0.00385) -200 to 200°C / -328 to 392°F
Special Ratings: PtX10 ≤X≤ 1000 (a=0.00385) Upper Range Depending on X-Value
Input RTD
Pt100 (a=0.003902) -200 to 1000°C / -328 to 1832°F
• For FM approved 3-,4-wire connection
Pt100 (a=0.003916) -200 to 1000°C / -328 to 1832°F
device, add suffix “FM” Ni100 (1) -60 to 250°C / -76 to 482°F
to the part number Ni1000 (1) -10 to 150°C / 14 to 302°F
• For ATEX approved Input
device, add suffix Potentiometer 3-,4-wire connection, 0 - 2000 Ω
“ATEX” to the part Resistance
number
Input Thermocouples Types: B, C, E, J, K, N, R, S, T
Input mV -10 to 500 mV
Sensor Failure User Definable Output
User Specified Information Adjustments - Zero Any Value Within Range Limits
(programmed by NANMAC) Minimum Spans 100° either F or C

1) Input Sensor Type


Output 4-20 mA, Temperature Linear
Operating Temperature -20 to 70°C / -4 to 158°F
2) Cold Junction
(thermocouple only, default is 32°F Galvanic Isolation 1500 VAC, 1 min.
/ 0°C)
6.5 to 36 VDC
3) Temperature Scale °F or °C Power Supply
8 to 30 VDC
4) Temperature Range
(full sensor range as default) ATEX: II (1) G [EEx ia] IIC
Intrinsic Satety
(Mounting in safe area) FM: Class I-III, Div. 1, Gr. A-G
5) Sensor Break Detection
(upscale or downscale - upscale is Typical Accuracy ±0.1% of Temperature Span
default)
Connection Head Rail acc. to DIN EN50022, 35mm

98 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Thermocouple Extension Wire
G9 Series

When selecting: insulation, moisture, abrasion,


flexing, chemical attack, temperature extremes, and
other adverse environments must be evaluated.
Insulations are rated for a maximum continuous
use temperature. This maximum use temperature
is for the insulation material, not the temperature
at which the thermocouple is operating. That
temperature limit is based on the thermocouple
design and calibration.

Thermocouple EXTENSION grade wire (denoted by an “X”) has approximately the same
thermoelectric properties as thermocouple wire, but is only guaranteed accurate within a
limited temperature range. Typically, under 400 degrees Fahrenheit. All thermocouple wire
is supplied to your specified length.
### X ##
Part Number = Insulation Material Wire Size

Extension Wire for Types CX, E, J, K, N, RX, SX & T


Insulation Material CX E J K N RX SX T
PVC over each/overall (801) rated to - - - - - - - 801T24
175°F - 801EX20 801JX20 801KX20 - 801RX20 801SX20 -
PVC, shielded w/drain wire (805) rated 805CX20 - - - 805NX20 805RX20 805SX20 805TX20
to 175°F - - 805JX20 805KX20 - - - 805TX20
- 809E30 809J30 - - - - 809T30
Teflon FEP wrapped (809) rated to 500°F - 809E24 809J24 809K24 - 809RX24 809SX24 809T24
- - 809J20 809K20 - 809RX20 809SX20 809T20
- - 810J30 810K30 - - - 810T30
Teflon TFE extruded (810) rated to 400°F 810CX24 810E24 810J24 810K24 810N24 810RX24 810SX24 810T24
- 810E20 810J20 810K20 - 810RX20 810SX20 810T20

G
- - - 812K20 812N20 - - -
Nextel braided (820) rated to 2,600°F
- - - - - - - -
- - 828J30 828K30 - - - -
- - - 828K28 - - - 828T28
Fiberglass braided (828) rated to 900°F - 828E24 828J24 828K24 828N24 828RX24 828SX24 -
828CX20 828E20 828J20 828K20 - 828RX20 828SX20 828T20

Temperature Ranges and Accuracy of Thermocouples & RTDs


Temperature Ranges by Sensor Type

Useful Range B C B E J K N R S T Pt100


°C 0 / 1,700 0 / 2,320 0 / 2,320 -200 / 900 0 / 750 -200 / 1,250 -270 / 1,300 0 / 1,450 0 / 1,450 -200 / 350 -200 / 850
°F 32 / 3,092 0 / 4,230 0 / 4,230 -328 / 1,652 32 / 1,382 -328 / 2,282 -454 / 2,372 32 / 2,642 32 / 2,642 -328 / 662 -328 / 1,562
°C / °F
-200 / -328 - - - 1.0 - 2.0 2.0 - - 1.5 0.65
-100 / -148 - - - 1.0 - 2.0 2.0 - - 1.5 0.8
0 / 32 - - - 1.0 0.75 0.75 0.75 0.25 0.25 1.5 0.3
200 / 392 - - - 0.5 0.75 0.75 0.75 0.25 0.25 1.0 0.8
400 / 752 - 4.5°C 4.5°C 0.5 0.75 0.75 0.75 0.25 0.25 1.0 0.55
600 / 1,112 - 1.0 1.0 0.5 0.75 0.75 0.75 0.25 0.25 - 0.55
800 / 1,472 0.5 1.0 1.0 0.5 - 0.75 0.75 0.25 0.25 - 0.55
1,000 / 1,832 0.5 1.0 1.0 - - 0.75 0.75 0.25 0.25 - -
1,200 / 2,192 0.5 1.0 1.0 - - 0.75 0.75 0.25 0.25 - -
1,400 / 2,552 0.5 1.0 1.0 - - - - 0.25 0.25 - -
1,600 / 2,912 0.5 1.0 1.0 - - - - - - - -
1,800 / 3,272 - 1.0 1.0 - - - - - - - -
2,000 / 3,632 - 1.0 1.0 - - - - - - - -
2,300 / 4,172 - 1.0 1.0 - - - - - - - -

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 99


Multi-Pair Thermocouple Cable
G10A Series

Multi-pair extension cables are available for thermocouple


calibration types E, J, K, N & T. Each conductor is covered with
a polyvinyl chloride (PVC) jacket having a nominal thickness
of 0.015 inch. Pairs are individually twisted to reduce magnetic
interference. The twisted pairs are cabled and then shielded
with a 0.0015 inch think aluminum-backed mylar tape and
a #20 gage stranded copper drain wire to further minimize
electromagnetic interference. The cable is then covered with an
outer layer of PVC about 0.045 inch thick. A heavy, easy-strip
nylon thread is included. Each cable also contains a polyvinyl-
clad #20 gage copper wire for use as a signal connection.
Cables are color coded on the individual conductors and
overall. The individual pairs are marked for easy identification.
NOTES:
• Temperature rating of this cable is based upon the limits of the PVC insulation. The continuous
use limit of this cable is 176 degrees Fahrenheit (80 degrees Celsius).
• Volume discounts apply on quantities over 500
feet. Specifications
• All multi-pair cable is supplied to your specified
length, plus/minus 10 percent. Thermocouple Number
Part No.
Calibration of Pairs
• For special multi-pair cables with other G10A-1 4
calibrations, other insulations, metallic overbraid, G10A-2 8
etc. contact factory. G10A-3 Iron / Constantan 12
• Maximum continuous length is 300 feet. For G10A-4 Type JX 16
longer lengths consult factory. G10A-5 20
G10A-6 24
G10A-7 4
G10A-8 8
G10A-9 Chromel / Alumel 12
G10A-10 Type KX 16
G10A-11 20
G10A-12 24
G10A-13 4
G10A-14 8
G10A-15 Copper / Constantan 12
G10A-16 Type TX 16
G10A-17 20
G10A-18 24
G10A-19 4
G10A-20 8
Specifications G10A-21 Chromel / Constantan 12
G10A-22 Type EX 16
Number Overall Size Shipping Weight G10A-23 20
of Pairs (in.) (pounds per 1,000 feet) G10A-24 24
4 0.390 85 G10A-90 4
8 0.480 130 G10A-91 8
12 0.590 200 G10A-92 NiCh / NiSi 12
16 0.650 245 G10A-93 Type NX 16
20 0.730 285 G10A-94 20
24 0.770 340 G10A-95 24

100 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Coil Cord Cable
for Thermocouples and RTDs
G10B Series

Our PVC insulated retractable coil cords are available


in thermocouple alloy types E, J, K & T. Three wire
copper units are available for RTDs and thermistors. Wire
conductor construction consists of #28 gauge standard
wire. The PVC insulation has excellent abrasion and
moisture resistance and is usable at temperature to 176
degrees Fahrenheit (80 degrees Celsius) continuously.
The one foot coil will stretch to four feet and retract to its
original length thousands of times. Applications include
oscillating machinery, handheld probes, etc.

Since these cables have a relatively high internal impedance (up to 34 ohms) they should
not be used with low impedance type, analog panel meters. They are ideal for digital and
analog type indicators or controllers having an input resistance of 50 ohms or greater.
NOTES:
• Termination styles are available upon
• Tolerance of ±10% on length, diameter, and request.
resistance.
• Consult factory for coils other than 12
• Probes sold separately inches long and special requirements.

Specifications
Approximate
Part No. Type Color-Code Ohms / 12” (coiled)
Cable Diameter (in.)
G10B-1 J Black 16.5 0.180
G10B-2 K Yellow 27.5 0.180
G10B-3 T Blue 14.0 0.180
G10B-4 E Purple 33.5 0.180
G10B-5 RTDs or Thermistors White 0.60 0.180

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 101


Mineral Insulated Thermocouple Cable
G11 Series

Nanoclad wire is a metal sheathed inert


magnesium oxide insulated thermocouple cable. It
is used to fabricate thermocouple probes and high
temperature thermocouple extension wire. It can
be welded, brazed, bent, coiled, or formed. This
mineral insulated wire can withstand vibration under
high temperatures and pressure.

Specifications
Thermocouple Sheath Sheath Wall Wire
Part No.
Type Material Diameter (in.) Thickness (in.) Diameter (in.)
G11-2 0.040 0.007 0.006
G11-3 0.062 0.010 0.010
G11-4 0.125 0.018 0.020
J SS 304
G11-5 0.188 0.025 0.032
NOTES: G11-6 0.250 0.036 0.040
G11-6A 0.080 0.015 0.014
• All cables will be G11-8 0.040 0.007 0.006
furnished to your G11-9 0.062 0.010 0.010
specified total length, G11-10 J Inco 600 0.125 0.018 0.020
plus or minus ten G11-11 0.188 0.025 0.032
percent. G11-12 0.250 0.036 0.040
• For other sizes, G11-14 0.040 0.007 0.006
alloys, and insulation G11-15 0.062 0.010 0.010
contact factory. G11-16
K SS 304
0.125 0.018 0.020
G11-17 0.188 0.025 0.032
• Multi-conductor cable G11-18 0.250 0.036 0.040
is available for most G11-18A 0.080 0.015 0.014
sheath sizes.
G11-20 0.040 0.007 0.006
• When ordering, G11-21 0.062 0.010 0.010
specify part number G11-22 K Inco 600 0.125 0.018 0.020
and length. G11-23 0.188 0.025 0.032
G11-24 0.250 0.036 0.040
• Minimum length
orders apply, contact G11-26 0.040 0.007 0.006
factory for you G11-27 0.062 0.010 0.010
specific requirement. G11-28 0.125 0.018 0.020
T SS 304
G11-29 0.188 0.025 0.032
• Thermocouple Type G11-29A 0.250 0.036 0.040
N is also available - G11-29B 0.080 0.015 0.014
Contact Factory G11-30 0.040 0.007 0.006
G11-31 0.062 0.010 0.010
G11-32 0.125 0.018 0.018
E SS 304
G11-33 0.188 0.025 0.032
G11-33A 0.080 0.015 0.014
G11-33B 0.250 0.036 0.040
G11-34 0.040 0.007 0.006
G11-35 E Inco 600 0.62 0.010 0.010
G11-36 0.125 0.018 0.020

102 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Digital Thermometers
and Data Loggers
H1 Series

Low cost, compact size thermometers features single or dual channel temperature
measurements with dual display (order probes separately).

Model Number Digital Thermometer


H1-80: Single Channel, Type K
H1-81: Dual Channel, Type K

H1-80s - Common Specifications


Resolution 0.1°C / 0.1°F below 1,000°C / °F
Accuracy ±(.01% reading +0.7°C), ±(0.1% reading + 1.4°F)
Type K Range -200°C/1,372°C (-328°F/+2,500°F)
Function °C/°F, MAX, MIN, HOLD, REL, MEM LIMIT, Hi/Lo, TYPE, T1-T2
Power Auto Power OFF
Interface Optional RS-232 interface with Windows®
Approval CE Approval, to ITS-90

Store up to 10,000 readings for each channel with a perpetual calendar real time function.
The unique CALL-FIT function allows you to read & search the desired log data from memory
at a speed of 50 pages per second. All the data collected by the data-logger during long-term
monitoring can be transmitted to computers for further analysis using Windows® software
(order probes separately).

Model Number Digital Thermometer & Data Logger


H1-91: Dual Channel, Selectable E/J/K/N/R/S/T
H1-92: Four Channel, Selectable E/J/K/N/R/S/T

NOTE:
• RTD models also available H
H1-80s - Common Specifications
Resolution -0.1°C / 0.1°F below 1,000°C / °F
Function °C/°F/K, MAX, MIN, AVG, HOLD, REL, LIMIT, Hi/Lo, TYPE,
COUNT, TIME, CLOCK, CHANNEL, T1-T2, T3-T4, BACK-
LIGHT, RS232, REC, CALL
Power Auto Power OFF
Interface Optional RS-232 interface with Windows®
Approval CE Approval, to ITS-90

All H1-90s include USB cable and data logging software!


Software and manuals are downloaded from Nanmac.com

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 103


Handheld Thermocouple Probes
for Moving or Rolling Surface Measurement
H2 Series

These thermocouple probes are provided in type K thermocouple calibration. A plastic


handle with a retractable coil cord and miniature plug is attached. Contact us for your
design requirement. Refer to our Handheld Data Logger / Thermometer and/or Handheld
Thermometer which utilize these temperature probes.

H2-5BA
H2-5BA H2-5C H2-5D • Roller surface, right
angle St rollers for
moving or rotating
smooth surfaces (roller
diameter = 0.75 inch).
480°F
H2-5C
250°C
• Roller surface, bearing
rollers for smooth
plastic and steel pipe
plus moving or rotating
surfaces (roller diameter
= 0.63 inch).
H2-6A H2-8 H2-6 H2-5D
• Miniature teflon rollers
for moving or rotating
surfaces in food
480°F processing (roller
diameter = 0.63 inch).
250°C
H2-6A
• Magnetic surface probe
(one ribbon) allows for
sensor to be attached
to measuring target (no
handle).
H2-006 H2-005 H2-007 H2-3B H2-8
• Moving surface probe
ideal for measuring
moving or stationary flat
1,470°F metal or plastic surfaces.
800°C H2-6
• Magnetic surface
probe (three ribbon)
designed for stationary
surfaces, ideal for griddle
temperatures.

H2-006 H2-005 H2-006 H2-3B


• Sharp tip probe for • General purpose • General stationary • General stationary
frozen and semi- probe, 1/8 inch surface probe with surface probe,
solids. stainless steel. ceramic tip and extended reach.
spring.

104 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Digital Displays & Controllers
H3 Series

NOTES:
• Field selectable inputs
• 4-20 mA, ±10 V, thermocouple calibration
types: E, J, K & T and Pt100 RTD inputs
• NEMA 4X, IP 65 front panel
• Shallow depth case 3.5” behind panel
• Serial communication adaptor options
• Two form C 3 A relays option
• Selectable fail-safe operation
• Latching or non-latching
• Pump alteration control
• On & Off time delays
• 23 VDC @ 200 mA supply option
• Modbus® RTU option
• 4-20 mA output option
• Dual 24 VDC supplies option

Sunlight Readable Display

• Standard feature - no extra charge


• Viewable under direct sunlight
• Mount outside or inside

Serial Communications

• RS-232 & RS-422/485 adaptors


• RS-232 & RS-422/485 converters
• USB to RS-422/485 converters
• Data acquisition & programming

Specifications
Part No. Installed Options Power Required
H3-PD765-6R0-00 None 85-265 VAC
H3-PD765-6R0-10 24 VDC Supply Output 85-265 VAC
H3-PD765-6R2-00 2 Relays 85-265 VAC
H3-PD765-6R2-10 2 Relays & 24 VDC Supply Output 85-265 VAC
H3-PD765-6R3-00 4-20 mA Output 85-265 VAC
H3-PD765-6R3-10 4-20 mA Output & 24 VDC Supply Output 85-265 VAC
H3-PD765-6R3-20 4-20 mA Output & Dual 24 VDC Output 85-265 VAC
H3-PD765-7R0-00 None 13-36 VDC
H3-PD765-7R2-00 2 Relays 13-36 VDC
H3-PD765-7R3-00 4-20 mA Output 13-36 VDC

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 105


Thermocouple Simulator / Calibrator
Simulate Types: C, E, J, K, N, R, S & T
H14-KIT Series

High Accuracy Calibration function simulates precision


thermocouple outputs for use in calibrating thermometers,
transmitters, controllers or recorders. A Calibration cable
connects the meter to other thermocouple devices. Simply
adjust the output knob to display the desired temperature
and calibrate your instrument to its accuracy specification.
Versatile thermometer function displays temperatures
over a wide range. Switchable from degrees Fahrenheit to
degrees Celsius for increased versatility in both measure
and calibrate modes. Unique Oyster case design features
large digital display built into “flip-up” cover which adjusts
(from 90 degrees to 180 degrees) for best viewing angle.
NOTES: Automatically shuts off when closed. Portable and rugged
• Complete with thermocouple industrial design for field, plant or bench top use. Neckstrap
calibration type K, copper
calibration cable, 9V NiCad included for hands-free operation. Operates on battery or
rechargeable battery, AC adaptor.
neckstrap, AC adaptor/
recharger, and case.
• High accuracy calibration
function simulates precision
thermocouple outputs for use
in calibrating thermometers,
transmitters, controllers, or
recorders.
• Accuracy of 0.15% of reading
over wide ranges
• 0.1 degrees / 1 degrees
resolution for E, J, K & T
types; 1 degrees for C, N, R &
S types.
Specifications
• Degrees Celsius / Degrees
Fahrenheit switchable for Type Ranges for Calibrate and Measure modes Accuracy
increased versatility
J -58 to 1,830°F (-50 to 1,000°C) 0.15% rdg ±1°
• Displays output in terms of K -58 to 2,498°F (-50 to 1,370°C) 0.15% rdg ±1°
millivolts or temperature T -184 to 752°F (-270 to 400°C) 0.15% rdg ±1°
E -58 to 1,382°F (-50 to 750°C) 0.15% rdg ±1°
• Folded Dimensions: C -32 to 4,172°F (0 to 2,300°C) 0.15% rdg ±1°
3.8 x 4 x 1.8” R -32 to 3,182°F (0 to 1,750°C) 0.15% rdg ±1°
(96 x 108 x 45mm) S -32 to 3,182°F (0 to 1,750°C) 0.15% rdg ±1°
N -58 to 2,372°F (-50 to 1,300°C) 0.15% rdg ±1°
-5.00mV to
Voltage
±55.00mV
Resolution 0.1° (up to 999.9) or 1° (over 999.9°)
Cold Junction 0.03°C/°C (0.02°F/°F)
Input Junction 10Mohm
Sampling Time 4 times/second
Dims/Weight 3.8 x 4.2 x 1.8” (96 x 108 x 45mm)/17oz.

106 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Infrared Thermometers
H32 Series

Infrared Non-Contact Digital Thermometer (H32-50) H32-50


Features:
• Laser sighting to pinpoint target area
• LCD display with backlighting
• Temperature Unit Switchable: °C or °F
• Auto data hold when trigger is released
• Emissivity fixed at 0.95 (suits 90% of
applications)
• Standard package: meter, instruction
manual, and battery

H32-50 - Specifications
Temperature Range -40°F to 600°F (-40°C to 320°C)
Resolution 0.1°F (-20 to 212°F) otherwise 1°F
Distance Ratio 8:1
Emissivity Fixed at 0.95
Accuracy ±2.5% or ±5°F (3°C) at 0 to 392°F, H32-60
otherwise ±3%
Power 9 Volt Battery x 1
Auto Power Off After 6 seconds once trigger is
released
Dimensions 5.2 x 2.6 x 1.3” (157 x 80 x 40mm)

Hi-Temp Infrared Non-Contact Digital Thermometer (H32-60)

Features:
• Laser sighting to pinpoint target area
• LCD display with backlighting
• Temperature Unit Switchable: °C or °F
• Auto data hold for 10 seconds with no
operation H
• Emissivity 0.30 to 1.00 adjustable
• Standard package: meter, instruction
manual, and battery Quick Comparison
(see full specifications above)
H32-60 - Specifications Part No. H32-50 H32-60
Temperature -40°F to 600°F -40°F to 932°F
Temperature Range -40°F to 932°F (-40°C to 500°C) Range (-40°C to 320°C) (-40°C to 500°C)
Resolution 0.1°F (-20 to 212°F) otherwise 1°F
Distance Ratio 10:1 Distance
8:1 10:1
Emissivity 0.30 to 1.00 adjustable Ratio
Accuracy ±2% at 0 to 392°F, otherwise ±3%
Emissivity Fixed at 0.95 0.30 to 1.00 adjustable
Power 9 Volt Battery x 1
Auto Power Off After 10 seconds with no operation ±2% at 0 to 392°F, ±2% at 0 to 392°F,
Accuracy
Dimensions 5.2 x 2.6 x 1.3” (157 x 80 x 40mm) otherwise ±3% otherwise ±3%

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 107


Temperature and Process Controllers
Proportional • PID • Ramp Soak • Limit
H34 Series

The H34-540 Series is 1/16 DIN or 1/4


DIN temperature controller with auto tuning
PID control capabilities. One of four user
programmable set points may be selected.
For PID control in the form of time proportional
relay on/off output, time proportional voltage
pulse, or 4-20 mAmp signal control. Its universal
input accepts 23 inputs varieties, including
thermocouple, RTD, and voltage inputs can be
easily configured for a 4-20 mAmp input. The
relays may be programmed as alarms with 20
different high, low, and deviation alarm types
which can include fail-safe operation. Digital
input options add the ability of external contacts
to operate the controller. With RS-485 serial
communication options include protocols for
master/slave set point control, modbus ASCII
and RTU.

The H34-550 Series is 1/16 DIN or 1/4 DIN


ramp and soak controller with auto-tuning PID
control capabilities. Two programs store 15
segments each for precision set point control. At
the completion of a program, the controller can
hold a set point, stop the outputs, or loop the
completion of a program. Thus, enabling one
30 segment program to be used. Its universal
input accepts 23 inputs varieties, including
thermocouple, RTD, and voltage inputs can
easily be configured for a 4-20 mAmp input.
The relays may be programmed as alarms with
20 different high, low, and deviation alarm types
which include fail-safe operation. Digital input
options add the ability of external contacts to
operate the controller and digital output options
are available. With RS-485 serial communication
options include protocols for master/slave set
point control, modbus ASCII and RTU.

108 Tel: 800.786.4669 | Int’l: 001.508.872.4811


H34-540 Series Temperature Controllers - Specifications

Part No. DIN Size Description


H34-540-6RA-11 1/16 2 Relays, 1 Analog Output, 2 Digital Inputs, Heating or Cooling
H34-540-6RA-14 1/16 2 Relays, 1 Analog Output, RS-485 Communication, Heating or Cooling
H34-548-6RB-21 1/4 3 Relays, 2 Analog Outputs, 2 Digital Inputs, Heating or Cooling
H34-548-6RB-24 1/4 3 Relays, 2 Analog Outputs, RS-485 Communication, Heating or Cooling
H34-549-6RB-24 1/4 3 Relays, 2 Analog Outputs, RS-485 Communication, Heating & Cooling

H34-550 Series Ramp Soak Controllers - Specifications

Part No. DIN Size Description


H34-550-6RA-14 1/16 2 Relays, 1 Analog Output, RS-485 Communication
H34-558-6RA-26 1/4 3 Relays, 2 Analog Outputs & 4 Digital Inputs, RS-485 Communication

H34-570 Series Limit (On/Off) Controllers - Specifications

Part No. DIN Size Description


H34-570-6RA-10 1/16 1 Latching Relay, 1 Alarm Relay, 1 Analog Output
H34-578-6RA-14 1/4 3 Relays, 1 Analog Outputs & 4 Digital Inputs, RS-485 Communication

Specifications
Input Thermocouple Temperature
Acccuracy*
Type Type Range
B 32 to 3,300°F (0 to 1,800°C) > 400°C : ±0.15% FS ±1 digit
< 400°C : ±5% ±1 digit
C (W5) 32 to 4,200°F (0 to 2,300°C) ±0.2% FS ±1 digit
E -300 to 1,800°F (-199.9 to 999.9°C) > 0°C : ±0.1% FS ±1 digit
J -300 to 2,300°F (-199.9 to 999.9°C) < 0°C : ±0.2% FS ±1 digit
K 0 to 2,300°F (-199.9 to 999.9°C) > 0°C : ±0.1% FS ±1 digit
L -300 to 1,600°F (-199.9 to 900.0°C) > 0°C : ±0.25% FS ±1 digit
Thermocouple
N -300 to 2,400°F (-200 to 1,300°C) > 0°C : ±0.1% FS ± digit
< 0°C : ±0.25% FS ±1 digit
Platinel II 32 to 2,500°F (0 to 1,390°C) ±0.1% FS ± digit
R
S
32 to 3,100°F (0 to 1,700°C)
32 to 3,100°F (0 to 1,700°C)
±0.15% FS ±1 digit H
T -300 to 750°F (-199.9 to 400.0°C)
U -300 to 750°F (-199.9 to 400.0°C)
JPtA -199.9 to 999.9°F (-199.9 to 500.0°C) ±0.1% FS ±1 digit**
JPtB -199.9 to 300.0°F (-150.0 to 150.0°C)
RTD PtA -300 to 1,560°F (-199.9 to 850.0°C) ±0.1% FS ±1 digit**
PtB -199.9 to 999.9°F (-199.9 to 500.0°C)
PtC -4.0 to 212.0°F (-19.99 to 99.99C) ±0.2% FS ±1 digit
0.4 to 2.0V 0.400 to 2.000 ±0.1% FS ±1 digit
1.000 to 5.000 1.000 to 5.000 Display range can be scaled between -1999 and 9999.
Process 0 to 10V 0.00 to 10.00 4 to 20 mA Input
-10 to 20mV -10.00 to 20.00 To accept a 4 to 20 mA signal, select 0.4 to 2.0 VDC input
0 to 100mV 0.0 to 100.0 and connect a 100Ω resistor across the input terminals.

*Performance within recommended operating conditions (10 to 50°C, 20 to 90% RH)


**For a range scale of 0 to 100°C: ±0.3°C ±1 digit, and for a range scale of -100 to 100°C: ±0.5°C ±1 digit

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 109


RTD Probes
with Various Termination Styles
I6 Series

Our standard RTD probe uses a 100 ohm platinum element with alpha = 0.00385. Sheath
material is SS 304 and can be 1/16, 1/8, 3/16, or 1/4 inch diameter in standard length of
five inches. Units are available with either a standard size plug or teflon insulated lead wire.
When ordered with a plug; the plug has three prongs. Units with lead wire can be either two
or three conductor. Available with stainless steel overbraid for added durability.

Two-Wire Leads

Three-Wire Leads

Three-Prong Plug

1/16 and 1/8 inch diameter units have a transition between sheath and leads
Specifications
Termination Stainless Steel
Part No. Probe OD
Styles Overbraid Pt1000 also available
I6-20 3/16 No
I6-21 1/4 No
I6-22 3/16 Yes NOTES:
I6-23 1/4 Two-Wire Yes
I6-23A 1/8 Leads No • Various size mounting bushings are
I6-23B 1/8 Yes available for these units.
I6-23C 1/16 No • Longer sheath or lead wire lengths,
I6-23D 1/16 Yes four-wire units, and various sheath
I6-24 3/16 No materials are available.
I6-25 1/4 No
I6-26 3/16 Yes • A variety of termination styles are
I6-27 1/4 Three-Wire Yes available for these units.
I6-27A 1/8 Leads No • Typical construction does not allow
I6-27B 1/8 Yes for bending; contact factory if your
I6-27C 1/16 No requirement involves bending.
I6-27D 1/16 Yes
I6-28 3/16
• PFA Teflon® encapsulation - good to
I6-29 1/4 Three Prong 450°F, can be added to any probe.
N/A
I6-31A 1/8 Plug
I6-31B 1/16

110 Tel: 800.786.4669 | Int’l: 001.508.872.4811


RTD Assemblies
with General Purpose Heads
I7 Series

The standard probe contains Pt100 ohm RTD assembly with an aluminum general purpose
(GP) head. A terminal block is mounted on the interior of the GP head. The GP head has
1/2” NPT threads where the probe is mounted and a 1/2” NPT conduit outlet for your wire
connections. This RTD assembly is also available with a four inch long stainless steel support
tube for use with ceramic sheaths and adjustable mounting fittings. The support tube is an
1/8” larger in diameter than the sheath diameter. When ordering with support tube add the
suffix (ST) to the part number. Standard support tube is four inches long and can be made
to most any length required, mounting bushing is eliminated when ST is applied.

NOTES:
Specifications
• Types available: Pt100, Pt1000
Sheath Sheath
• Typical construction does not allow for bending, Part No.
Diameter Material
contact factory if your requirement involves bending. I7-1 0.062
• All sensors use two wire leads, three or four wire I7-2 0.125
SS 304
assemblies are also available. I7-3 0.187

• When ordering with support tube, add suffix ST to the


part number.
I7-4
I7-5
0.250
0.062
I
I7-6 0.125
Inco 600
• Standard support tube is four inches long, support I7-7 0.187
tube can be made to most any length required. I7-8 0.250
Contact the factory with any special requirement. I7-9 0.187
• Specify part number and length. I7-10 0.250 Quartz
Example: I7-6-18 I7-11 0.375
I7-12 0.187
• PFA Teflon® encapsulation - good to 450°F, can be I7-13 0.250 Al2O­3­ - 00.5%
added to any probe. I7-14 0.375

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 111


Electrical Feed-Thrus
for Thermocouples or Other Signals
K6 Series

Insulated electrical Feed-Thrus provide a ready-to-use


device, from two to twelve insulated electrical wires per
unit. Having flexible insulated leads on the pressure side
and various connection options on the ambient side. These
electrical sealing glands can also be used to carry electrical
current up to 0.8 amperes if desired. A wide choice of
instrumentation feedthrough glands are available for a variety
of applications, including various thermocouple calibrations,
various termination styles, and configurations for the ambient
side (lead wire, connectors, etc.)

Units are made with stainless steel glands and have either
O-ring (OR series), pipe thread (A series), or conical (HP
series) metal-to-metal seals. They can be rated for use from
low vacuum to 20,000 psi and temperatures to 500 degrees
Fahrenheit. All standard glands contain #24 gage (0.020”)
AWG solid copper conductors inside an 1/8 inch diameter
stainless steel tube. These copper conductors are insulated
from each other and the tube wall by a high temperature
ceramic. The 1/8 inch stainless steel tubes containing the
copper conductors are flexible and can be bent to most
any desired angle in a radius as small as 1/2 inch. The
stainless steel tube provides excellent shielding for each pair
of conductors against unwanted electromagnetic noise or
stray voltage pickup. These tubes, when more than one, are
staggered in length.

(Pressure/Vacuum Side) (Ambient Side)

112 Tel: 800.786.4669 | Int’l: 001.508.872.4811


NOTES: • Various terminations are available
(connectors, lead-wire, etc.) contact factory
• All conductors are 24 gage (0.020” with your particular requirements.
diameter) solid copper leads, thermocouple
type wire also available. • One thermocouple requires two wires.

OR Series A Series HP Series


Various therminations are available

All standard pressure and amperage ratings are based on 68°F conditions.

Specifications
Pressure
Part No. Conductors B C D E-thd E-hex F G H L
Rating (psi)
K6-1 2 1-7/16 13/32 7/16-20 3/4 1/8 - - -
K6-2A 4 2 15/32 3/4-16 1-5/16 1/8 - - -
5,000 psi As
K6-2B 6 2 15/32 3/4-16 1-5/16 1/8 - - -
(OR Series) Required
K6-2C 8 2 15/32 3/4-16 1-5/16 1/8 - - -
K6-2D 10 2 15/32 3/4-16 1-5/16 1/8 - - -
K6-6 2 27/32 3/8 1/8” NPT 7/16 1/8 - - -
K6-7 4 2 3/4 1/2” NPT 7/8 1/8 - - -
3,200 psi As
K6-8 6 2 3/4 1/2” NPT 7/8 1/8 - - -
(A Series) Required
K6-9 8 2 3/4 1/2” NPT 7/8 1/8 - - -
K6-10 10 2 3/4 1/2” NPT 7/8 1/8 - - -
K6-11
K6-12
10,000 psi
2
4
3
3
As
1.25
1.25
1-1/8-12
1-1/8-12
1-3/16
1-3/16
1/8
1/8
0.250
0.250
0.560
0.560
1
1 K
K6-13 6 3 1.25 1-1/8-12 1-3/16 1/8 0.250 0.560 1
(HP Series) Required
K6-14 8 3 1.25 1-1/8-12 1-3/16 1/8 0.250 0.560 1
K6-15 10 3 1.25 1-1/8-12 1-3/16 1/8 0.250 0.560 1

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 113


Accuracy and Range
of Thermocouples & RTDs

Thermocouples & RTDs

Temperature Range and Accuracy Tolerance of Commonly Used Thermocouples & RTDs
Thermocouple Type RTD
Range
B C D E J K N R S T Pt100
°C 0/1700 0/2320 0/2320 -200/900 0/750 -200/1250 -270/1300 0/1450 0/1450 -200/350 -200/850
°F 32/3092 32/4230 32/4230 -328/1652 32/1382 -328/2282 -454/2372 32/2642 32/2642 -328/662 -328/1562
°C / °F Accuracy (tolerance) is ± the values stated below. Values are percent of temperature, unless otherwise specified.
-200/-328 - - - 1.0 - 2.0 2.0 - - 1.5 0.65
-100/-148 - - - 1.0 - 2.0 2.0 - - 1.5 0.8
0/32 - - - 1.0 0.75 0.75 0.75 0.25 0.25 1.5 0.3
200/392 - - - 0.5 0.75 0.75 0.75 0.25 0.25 1.0 0.8
400/752 - 4.5°C 4.5°C 0.5 0.75 0.75 0.75 0.25 0.25 1.0 0.55
600/1112 - 1.0 1.0 0.5 0.75 0.75 0.75 0.25 0.25 - 0.55
800/1472 0.5 1.0 1.0 0.5 - 0.75 0.75 0.25 0.25 - 0.55
1000/1832 0.5 1.0 1.0 - - 0.75 0.75 0.25 0.25 - -
1200/2192 0.5 1.0 1.0 - - 0.75 0.75 0.25 0.25 - -
1400/2552 0.5 1.0 1.0 - - - - 0.25 0.25 - -
1600/2912 0.5 1.0 1.0 - - - - - - - -
1800/3272 - 1.0 1.0 - - - - - - - -
2000/3632 - 1.0 1.0 - - - - - - - -
2300/4172 - 1.0 1.0 - - - - - - - -

NOTES:
• Values are in an accordance with NIST Monograph 175, Revised to ITS 90
• Accuracy Values for Pt100 RTD are not to exceed values.
• All values shown are for Standard Limits of error class B limits.

Resistance Temperature Detectors (RTDs)


All metals will have change in resistance when subjected to a commonly used materials for RTDs are platinum and nickel. On
temperature change. This relationship can be predicted by use special applications, tungsten and copper are also used.
of a constant (alpha) temperature coefficient of resistance. No
two different metals have the same alpha and if the properties The sensing element of a RTD may consist of a coil, foil or thin
of the metal are known, a resistance vs. temperature curve film deposited material. This sensing element may be wound or
may be established which can be accurately duplicated. deposited onto a suitable insulating core and then encapsulated
with an insulating material. RTD extension leads may be of
A metal’s alpha may be changed by alloying it with any convenient material (typically copper wire with insulation
another material or by mechanically stressing it. Thus, only requirements to suit the environment of use) provided all leads are
a few materials are used for resistance temperature detectors of the same material. The number of extension wires can consist
(RTD). Other factors which limit the use of some metals and of two, three or four wires. Two extension leads are used where
alloys as RTDs include: low electrical resistance, difficulty the lead wire resistance is not very important. Higher accuracy
in forming coils, availability in the pure state, linearity of is achieved if three wires are used, the third wire compensating
resistance vs. temperature curve, long-term drift and stability for the lead wire resistance. Four leads are typically used only
characteristics, resistance to contamination and chemical with dual element RTDs. An RTD system consists of the sensor,
attack, etc. When all of these factors are considered, the most lead wire and an instrument/readout device.

114 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Index
Page Page
Ablation Studies Blind holes
Multi-Function Sensor (E13 Series) 78 Bayonet TCs (A5 Series) 4
Surface & In-Wall TCs (E6 Series) 75 Ribbon Bayonet TCs (A6A Series) 7
Eroding TCs (E12 Series) 77 Spring Loaded Pins (B9 Series) 59
Air Bolt Temperatures
Standard TCs (A8A Series) 11 Washer TCs (A6 Series) 6
Bare Wire TCs (A13 Series) 31 Bolt-Down TCs (A7 Series) 9
Unsheathed TCs (A14A Series) 33 Bombs/Vessels
Ribbon TCs (C2 Series) 61 Surface & In-Wall TCs (E6 Series) 75
Ribbon TCs for Eroding Gas (C5 Series) 63 ms Response Times (E12 Series) 77
Air in Pipeline Calibrating
Ribbon TCs (C2 Series) 61 Bare Wire TCs (A13 Series) 31
Ribbon TCs for Flowing Gas (C5 Series) 63 Certified Calibration Services (contact us)
Flared Union TCs (D3 Series) 70 Unsheathed TCs (A14A Series) 33
Tube Union TCs (D4 Series) 71 Reference Junctions (F11 Series) 94
Pipe-Thread Union TCs (D4A Series) 72
Charlayers
Flared Union RTDs (D3 Series) 70
Surface, In-Wall & Interface TCs (E6 Series) 75
Tube Union RTDs (D4 Series) 71
Eroding TCs (E12 Series) 77
Pipe-Thread Union RTDs (D4A Series) 72
Multi-Function Sensor (E13 Series) 78
Aluminum (molten)
Conduction Studies
Molten Aluminum TCs (A38 Series) 53
Surface & In-Wall TCs (E6 Series) 75
Angle Mounted Eroding TCs (E12 Series) 77
Pipe-Angle Extensions (A34 Series) 50 Multi-Function Sensor (E13 Series) 78
Aspirator Probes Connectors
Ribbon TCs (C2 Series) 61 Standard Plugs & Jacks (F2 Series) 79
Automotive Brake Pads Miniature Plugs & Jacks (F3 Series) 80
Surface & In-Wall TCs (E6 Series) 75 Panel Jacks & Jack Boxes (F4 Series) 81
Eroding TCs (E12 Series) 77 Contact Temperatures
Multifunction Sensor (E13 Series) 78 Handheld Ribbon TCs (F2 Series) 79
Bayonet / Twist Lock Handheld Spring TCs (B8 Series) 58
Bayonet TCs (A5 Series) 4 Spring Loaded Pins (B9 Series) 59
Ribbon Bayonet TCs (A6A Series) 7 Copper (molten)
Bearings Industrial TCs (A33 Series) 49
Surface & In-Wall TCs (E6 Series) 75 Molten Metal TCs (A37 Series) 52
Eroding TCs (E12 Series) 77 Cryogenic
Spring Loaded Pins (B9 Series) 59 Bare Wire TCs (A13 Series) 31
Blenders Unsheathed TCs (A14A Series) 33
Mixer TCs & RTDs (C10 Series) 67 Ribbon TCs (C2 Series) 61
Sanitary TCs & RTDs (C10 Series) 67 Cutting Tool Temperatures
Mounting Adaptors (C11 Series) 68 Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 115


Page Page
Films
Hi-Temp. Eco. with Plug (A11A Series) 22 Ribbon TCs (B2 Series) 54
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27 Flanges
Hi-Temp. Eco. with GP Head (A11B Series) 24 Flanges for T-wells (A27 Series) 43
Hi-Temp. TCs (Tungsten Coated) (A12D Series) 30 Washer TCs (A6 Series) 6
Surface & Interface TCs (E6 Series) 75 Bolt-Down TCs (A7 Series) 9
Duplex Sensors Fluid (pipelines)
Standard TCs with Plugs (A8A Series) 11 Standard TCs with Plugs (A8A Series) 11
Hvy. Duty Hi-Temp. TCs (A12 Series) 26 Flared Union TCs (D3 Series) 70
Industrial TCs (A33 Series) 49 Tube Union TCs (D4 Series) 71
Energy Conservation Pipe-Thread Union TCs (D4A Series) 72
Standard TCs with Plugs (A8A Series) 11 Eco. Union TCs (D7 Series) 74
Industrial TCs (A33 Series) 49 Flared Union RTDs (D3 Series) 70
Advanced TCs / Oxidizing (A38 Series) 53 Tube Union RTDs (D4 Series) 71
Exhaust Gas Pipe-Thread Union RTDs (D4A Series) 72
Standard TCs with Plugs (A8A Series) 11 Ribbon TCs for Sanitary Use (C6 Series) 74
Industrial TCs (A33 Series) 49 Friction Studies
Ribbon TCs (C2 Series) 61 Surface & In-Wall TCs (E6 Series) 75
Multi-Function Sensor (E13 Info) 78 Eroding TCs (E12 Series) 77
Exhaust Manifold Multi-Function Sensor (E13 Info) 78
Washer TCs (A6 Series) 6 Furnaces (+2,400°F)
Bolt-Down TCs (A7 Series) 9 Standard TCs with Plugs (A8A Series) 11
Ribbon TCs with Shield (B7 Series) 57 TCs with Connector Heads (A8E Series) 15
Spring TCs (B8 Series) 58 Hvy. Duty TCs (A33 Series) 49
Explosions Furnaces (inert gas)
Surface & In-Wall TCs (E6 Series) 75 Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26
Eroding TCs (E12 Series) 77 Hi-Temp. Eco. with Plug (A11A Series) 23
Multi-Function Sensor (E13 Info) 78 Hi-Temp. TCs (tungsten coated) (A12D Series) 30
Extension Wire Hi-Temp. with GP Head (A12D Series) 30
TC Extension Wire (G9 Series) 99 Hi-Temp. Eco. with GP Head (A11B Series) 24
Ceramic Sheath TCs (A35 Series) 51
Extrusion / Melt
Standard Plastic TCs (C2B Series) 62 Furnaces (oxidizing)
Absolute Plastic TCs (C8 Series) 65 Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26
In-Stream Plastic TCs (C8A Series) 66 Hi-Temp. Eco. with Plug (A11A Series) 23
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 26
Feed-Thru (instrumentation)
Hi-Temp. Eco. with GP Head (A11B Series) 24
TC Feed-Thru (K6 Series) 112
Ceramic Sheath TCs (A35 Series) 51
Feed-Thru (power)
Furnaces (up to 4,500°F)
TC Feed-Thru (K6 Series) 112
Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26
Feed-Thru (vacuum) Hi-Temp. Eco. with Plug (A11A Series) 23
TC Feed-Thru (K6 Series) 112 Hi-Temp. TCs (Tungsten Coated) (A12D Series) 30

116 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Page Page

Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27 Hi-Temp. Eco. with GP Head (A11B Series) 24
Hi-Temp. Eco. with GP Head (A11B Series) 24 Ceramic Sheath TCs (A35 Series) 51
Ceramic Sheath TCs (A35 Series) 51 Glass (molten)
Furnaces (vacuum) Hvy. Duty TCs (A33 Series) 49
Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26 Gradient Temperature Studies
Hi-Temp. Eco. with Plug (A11A Series) 23 Surface & In-Wall TCs (E6 Series) 75
Hi-Temp. TCs (tungsten coated) (A12D Series) 30 Eroding TCs (E12 Series) 77
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27 Multi-Function Sensor (E13 Info) 78
Hi-Temp. Eco. with GP Head (A11B Series) 24 Bare Wire TCs (A13 Series) 31
Ceramic Sheath TCs (A35 Series) 51
Gun Barrel Bore Surfaces
Gases Surface & In-Wall TCs (E6 Series) 75
Ribbon TCs (C2 Series) 61 Eroding TCs (E12 Series) 77
Ribbon TCs (flowing) (C5 Series) 63
Heat Transfer Studies
Ribbon TCs (sanitary) (C6 Series) 64
Surface & In-Wall TCs (E6 Series) 75
Gases (high velocity) Eroding TCs (E12 Series) 77
Ribbon TCs (C2 Series) 59 Multi-Function Sensor (E13 Info) 78
Ribbon TCs (flowing) (C5 Series) 63 Bare Wire TCs (A13 Series) 31
Multi-Function Sensor (E13 Info) 78
Industrial
Gases (in pipelines) Standard TCs with Plugs (A8A Series) 11
Ribbon TCs (C2 Series) 61 TCs with Connector Heads (A8E Series) 15
Ribbon TCs (flowing) (C5 Series) 63 Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26
Flared Union TCs (D3 Series) 70 Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27
Pipe-Thread Union TCs (D4A Series) 72 Hvy. Duty TCs (A33 Series) 49
Eco. Union TCs (D7 Series) 74 Ceramic Sheath TCs (A35 Series) 51
Flared Union RTDs (D3 Series) 70 Pipe-Angle Ext. (A34 Series) 50
Tube Union RTDs (D4 Series) 71
Internal Surface Temperatures
Pipe-Thread Union RTDs (D4A Series) 72
Surface & In-Wall TCs (E6 Series) 75
Ribbon TCs for Sanitary Use (C6 Series) 64
Eroding TCs (E12 Series) 77
General Purpose (+2,400°F) Ribbon TCs (C2 Series) 61
TCs with No Connectors (A8 Series) 10
Kilns
Standard TCs with Plugs (A8A Series) 11
TCs with No Connectors (A8 Series) 10
TCs with Flexible Leads (A8B Series) 12
Bare Wire TCs (A13 Series) 31
TCs with Armor Leads (A8C Series) 13
Unsheathed TCs (A14A Series) 33
TCs with Connector Heads (A8E Series) 15
Ceramic Sheath TCs (A35 Series) 51
Hvy. Duty TCs (A33 Series) 49
Ceramic Insulators (A14 Series) 32
General Purpose (high temperature) Mullite Protection Tubes (A30 Series) 46
Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26 Ceramic and Refractory Tubes (A31 Series) 47
Hi-Temp. Eco. with Plug (A11A Series) 23
Mixer
Hi-Temp. TCs (tungsten coated) (A12D Series) 30
Mixer TCs & RTDs (C10 Series) 67
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 117


Page Page
Plastic (extrusion/melt)
Sanitary TCs & RTDs (C10 Series) 67 Standard Plastic TCs (C2B Series) 62
Mixer Sensor Mounting Adaptors (C11 Series) 68 Absolute Plastic TCs (C8 Series) 65
Molding In-Stream Plastic TCs (C8A Series) 66
Standard Plastic Melt TCs (C2B Series) 62 Plastic (injection molds)
Absolute Plastic Melt TCs (C8 Series) 65 Standard Plastic TCs (C2B Series) 62
In-Stream Plastic Melt TCs (C8A Series) 66 Absolute Plastic TCs (C8 Series) 65
Molten Metals In-Stream Plastic TCs (C8A Series) 66
Copper, Brass, Zinc, Lead TCs (A37 Series) 52 Pressure Vessels
Molten Aluminum TCs (A38 Series) 53 Ribbon TCs (C2 Series) 61
Moving Wire Eroding TCs (E12 Series) 77
Rub & Contact TCs (B6 Series) 56 Profile Studies
Multi-Element Standard TC Assemblies (A8A Series) 11
Standard TCs with Plugs (A8A Series) 11 Hvy. Duty Hi-Temp. TCs (A12 Series) 26
Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26 Bare Wire TCs (A13 Series) 31
Hvy. Duty TCs (A33 Series) 49 Unsheathed TCs (A14A Series) 33
Multi-Function Sensor (E13 Info) 78 Reference Junctions
Multi-Function Reference Junctions (F11 Series) 94
Multi-Function Sensor (E13 Info) 78 Rocket Nozzles
Pipe Temperatures (external) Surface & In-Wall TCs (E6 Series) 75
Washer TCs (A6 Series) 6 Eroding TCs (E12 Series) 77
Pipe Clamp TCs (D6 Series) 73 Rotating Parts
Pipelines Rub & Contact TCs (B6 Series) 56
Standard TCs with Plugs (A8A Series) 11 Spring Loaded Pins (B9 Series) 59
Flared Union TCs (D3 Series) 70 RTDs
Tube Union TCs (D4 Series) 71 RTDs with Plugs & Jacks (I6 Series) 110
Pipe-Thread Union TCs (D4A Series) 72 RTDs with Ext. Leads (I6 Series) 110
Eco. Union TCs (D7 Series) 74 RTDs with Connector Heads (I7 Series) 111
Flared Union RTDs (D3 Series) 70 RTDs for Mixers (C8B Series) 62
Tube Union RTDs (D4 Series) 71 RTDs for Sanitary Mixers (C10 Series) 67
Pipe-Thread Union RTDs (D4A Series) 72 Flared Union RTDs (D3 Series) 70
Compression Fittings for Pipelines (A10 Series) 21 Tube Union RTDs (D4 Series) 71
Ribbon TCs for Sanitary Use (C6 Series) 64 Pipe-Thread Union RTDs (D4A Series) 72
Flow-Thru TCs & RTDs (D4A Series) 72 Compression Fittings for RTDs (A10 Series) 21
Piston Rings Cable Assemblies for RTDs (A8H-RTD Series) 19
Surface & In-Wall TCs (E6 Series) 75 Shock Tubes
Eroding TCs (E12 Series) 77 Surface & In-Wall TCs (E6 Series) 75
Plastic (blow molds) Eroding TCs (E12 Series) 26
Bayonet TCs (A5 Series) 4 Sintering
Ribbon Bayonet TCs (A6A Series) 7 Hvy. Duty Hi-Temp. TCs with Plug (A12 Series) 26

118 Tel: 800.786.4669 | Int’l: 001.508.872.4811


Page Page

Hi-Temp. Eco. with Plug (A11A Series) 23 Eroding TCs (E12 Series) 77
Hi-Temp. TCs (tungsten coated) (A12D Series) 30 Multi-Function Sensor (E13 Info) 78
Hvy. Duty Hi-Temp. with GP Head (A12A Series) 27 Wires (moving)
Hi-Temp. Eco. with GP Head (A11B Series) 24 Rub & Contact TCs (B6 Series) 56
Ceramic Sheathed TCs (A35 Series) 51
Soaking Pit
Hvy. Duty TCs (A33 Series) 49
Pipe-Angle Ext. (A34 Series) 50
Protection Tubes (A32 Series) 48
Thermocouple Wire
Insulated Ext. Wire (G9 Series) 99
Type B 99
Type C 99
Type E 99
Type J 99
Type K 99
Type R 99
Type S 99
Type T 99
Thermowells
General Use T-wells (A21A Series) 37
T-wells with Lag Ext. (A22A Series) 38
T-wells (3/8”) (A23 Series) 39
T-wells (3/8” with Lag Ext.) (A24A Series) 40
T-wells (Hvy. Duty Taper) (A25 Series) 41
T-wells (Hvy. Duty with Lag Ext.) (A26A Series) 42
Flanges for T-wells (A27 Series) 43
T-wells for Flanges (A28 Series) 44
T-wells (Limited Space) (A29 Series) 45
Mullite Protection Tubes (A30 Series) 46
Ceramic and Refractory Tubes (A31 Series) 47
Protection Tubes (A32 Series) 48
Compression Fittings for T-wells (A10 Series) 21
Temperature Transmitters
Non-Isolated (Head Mount) (F11-40 Series) 95
Non-Isolated (Rail Mount) (F11-40RM Series) 96
In-Head Displays (F7-LCD Series) 90
In-Head Displays (NEMA) (F7-LCD-SP Series) 91
Wear Rates
Surface & In-Wall TCs (E6 Series) 75

©2011 Nanmac Corp. | 11 Mayhew St. | Framingham, MA 01702 USA 119


Terms and Conditions of Sale
PRICES: Prices are those in effect at time of order, prices SHORTAGES: Claims against Seller for shortages in the
are subject to change without notice. Quoted prices and amount shipped must be made within seven (7 days after
discounts apply only to the specific quantities of items arrival of shipment.
or specific services stated and do not include any taxes,
transportation charges, special packaging or labeling or RETURNS: Most items are made to order; therefore, it
other miscellaneous items or services not specified. Pric- is up to the Seller’s discretion to accept any item for re-
es are subject to corrections for errors. When so stated turn. No returns will be accepted without seller’s prior
on the quotation, prices invoiced will be those in effect authorization.
at the time of shipment.
VARIATION IN QUANTITY: On orders for Insulated Wire,
TAXES: The amount of tax or government charges upon cable, mineral insulated wire, or bare wire, Seller re-
the production, sale shipment and/or use of goods sold serves the right to ship, and invoice accordingly, plus or
hereunder, now imposed by any governmental authority minus ten percent (10%) of the total amount ordered.
or hereafter becoming effective shall be added to the
prices herein provided, and shall be paid by the buyer. WARRANTY: Any liability of Seller resulting from any de-
fect in workmanship or material in the product covered
PAYMENT TERMS: Payment terms are net cash 30 days by this document shall be limited to and fully discharge
from the date of the invoice once an open account has by replacement or repair or such item at Seller’s option
been established through the Seller’s credit application without charge. The warranty provided in this clause is
process, or Visa or MasterCard at the time of order, or in lieu of all other warranties, express or implied, aris-
C.O.D., unless otherwise stated in a quotation or agreed ing by law or otherwise, INCLUDING THE IMPLIED WAR-
to in writing by both the Seller and Buyer. Buyer agrees RANTIES OF MERCHANTABILITY AND FITNESS FOR A
to pay a late payment charge of 1-1/2% per month on PARTICULAR PURPOSE, and shall not be modified except
any amount or balance owed for more than 30 days. by an arrangement signed by both parties specifically
Buyer also agrees to pay all charges, fees and legal fees referencing this clause. In no event shall Seller be li-
in addition to the aforementioned late charge arising out able for consequential damages or extend beyond the
of the Seller’s efforts to collect any amount or balance repair or replacement of the defective purchased items.
owed. The Buyer must give notice of any defect in workmanship
or material to the Seller within seven (7) days after deliv-
DELIVERY: All shipment dates quoted are after receipt ery to Buyer. In the event the Buyer fails to give notice
and acceptance of order, unless otherwise specified. The within the specified period, the Seller will be relieved of
Seller shall not be liable for delays, losses or failures of all liability hereunder and Buyer agrees to accept goods
performance caused by fires, explosions, floods, other as is. Any action for breach of this warranty or other
actions of the elements, strikes or other labor disputes action arising out of this contract must be commenced
from whatever cause arising, embargoes, riots, acci- within one year after delivery.
dents, acts of public enemies, and/or rules, regulations,
orders or acts of government, delays of carriers, lack ACCEPTANCE: Quoted prices will remain firm for thirty
of transportation facilities, shortages of available fuel or (30) days from the date of quotation and are contingent
other sources of energy, or of basic raw materials or upon the acceptance of all terms and conditions listed
any other causes beyond the reasonable control of Seller. herein, unless otherwise stated in the quotation. All or-
The Seller shall not in any event be liable for consequen- ders are subject to review and final acceptance by the
tial or special damages arising out of delay due to any Seller at its home office in Framingham, MA - USA.
cause or for failure to give notice of any delay.
CANCELLATIONS: Seller’s acceptance of order cancel-
SHIPMENT: All shipments will be made F.O.B. place of lation or order reduction requests is conditioned upon
shipment unless otherwise specified or agreed to by the receiving buyer’s written agreement to assume Seller
Seller. In the absence of specific instructions, the Seller specified termination charges and/or price adjustments.
will select the carrier. Title to the material and risk of As most items are made to order, once an order has
loss shall pass to the Buyer upon delivery thereof by the been placed and processed it cannot be cancelled. Items
Seller to the carrier or delivery service. All packages will cannot be returned; there is no provision in the seller’s
be shipped insured for full product value unless specified terms for restocking any items.
otherwise in writing by the customer at the time of order.
In the event that something is damaged in shipment, it CHANGES: Seller may from time to time change their
is up to the customer/receiving party to initiate a dam- terms and conditions of sale. By agreeing to these terms
age claim with the carrier within 48 hours. Damaged and conditions, Buyer agrees to changes that may occur
items should be immediately repackaged in the origi- from time to time. Any changes to terms and condi-
nal packaging exactly as the customer/receiving party tions will be available to Buyer upon request and are
received them. not broadcast, printed or sent to Buyer as a matter
of course.

USE & PERFORMANCE: The determination as to the performance and/or adaptability of any of the
Seller’s products or materials to the specific needs and requirements of the purchaser is solely the
purchaser’s responsibility. The seller’s engineering department will gladly offer suggestions and
provide physical and electrical characteristics of commonly used materials, as they are available.

120 Tel: 800.786.4669 | Int’l: 001.508.872.4811