1. Where should you get a permit for demolition works: Office of the Building Official (OBO)
2. What should be affixed in the drawing for submission to acquire a building permit: Seal with
architect’s PRC registration number, name and the title “Architect”
3. what surveying activity undertaken to make sure of the lot lines of the site so as to have a
good reference as you start the schematic phase of the project: Relocation Survey
Compensation/Fees
1. Your client asked you to do ocular inspection, attend conference, and do presentation
meetings. How should you be compensated: Per Diem, Honorarium plus Expenses
2. Total compensation for Acoustical Design project worth 6M:
Cost of work = 6M
RPF = 10%-15% of CoW
RPF = (6M x 10%) to (6Mx15%)
RPF = 600,000 to 900,00
3. How Much is the initial payment for the acoustical design worth 6M:
Additional Notes:
1. Roles of an Architect
Code of Ethical Conduct, Section 2
o Duties and Responsibilities – The Architect’s honesty of purpose must be beyond
reproach.
He/she act as a professional adviser to his/her Client and his/her must be
unprejudiced;
He/she is charged with the exercise of mediation and conciliation functions
between Client and Contractor and must with entire impartiality’
He/she has moral responsibilities to his/her
Professional associates and subordinates; and he/she is engaged in a duties
and responsibilities cannot be properly discharge unless hi/her motives,
conduct, sense of moral values, sensitivity, and ability are such as to
command respect and confidence
Code Standards
1. Parking
Perpendicular Parking: 2.5m x 5.0m
Parallel Parking: 2.15mx6.00m
Height of Urinal Lip: 0.48m
Minimum dimension of PWD Toilet: 1.70mx1.80m min
Distance of Overhang from property line: 0.75m min
Circular Stairs width for 50 occupants:
PD 1096
o Occupant load of more than fifty (50): 1.10m
o Occupant load of fifty (50) or less: 0.90m
o Occupant load less than ten (10): 0.75m
o Circular Stairways may be used as an exit provided the minimum width of run (tread
depth) is not less than 250 millimeters. All treads in any one flight between landings
shall have identical dimensions within a 5 millimeters tolerance.
RA 9514 Fire Code of the Philippines Section 10.2.5.4
2. Types of Construction
Type I – Wood Construction
Types II – Wood Construction with protective fire-resistant materials and 1 hour fire-
resistive throughout
Type III – Masonry and Wood Construction with protective fire-resistive materials and 1
hour resistive throughout, incombustible exterior walls
Type IV – Steel, iron, concrete, or masonry construction incombustible interiors (ceilings &
walls)
Type V – Steel, iron, concrete or masonry four (4) hour fire-resistive throughout
3. How many percent should indigenous plant be found in a plant strip as per the Green
Building Code: 50%
4. Environmental Compliance Certificate (ECC)
5. Live load in kg/sqm for the ground floor: 150kg/sqm
6. Wind load Roof: 120kg/sqm
7. Ceiling height for elevator lobby: depends
8. Entrance ramp slope should not exceed: 1:12 (BP344)
9. If the bldg. is elevated 0.15m from the NGL, what is the entrance ramp length? If the bldg. is
elevated 0.15m from the NGL what is the riser height of the entrance step?
Entrance Ramp Length: 0.15mx12= 1.80m
Riser height: 150mm if one riser
10. Height of grab bar in mm for use at a water closet: 800mm
11. Distribution of Saleable and Non-Saleable Lands:
PD957: 70% saleable (max.) 30% non-saleable (min.)
12. Depth of footing if it encroaches beneath the sidewalk: 600mm
13. Min. depth of footing: 600mm
14. Min. thickness of footing: 250mm
15. Planting strips and Sidewalk:
Laws
1. Required grade to pass the licensure examination: weighted general average of seventy
percent (70%), with no grade lower than fifty percent (50%) in any given subject.
2. What is prescribed seal format: Registrant’s name, registration number and title
“Architect”
Awards/Honors
1. Highest award to be given a Fellow architect who has adhered to the highest standard of
professional and ethical conduct: Likha Gold Medal Award
2. An award annually given by the PRC for the professional: Outstanding Professional of
the Year Award
3. The highest award bestowed be Filipino artist who made a significant contribution to the
development of Philippine Arts: Order of National Artists`
4. Award given to regular member of UAP for outstanding contribution to the organization: