How Viscosity Affect Flow in Positive Displacement Pumps

You might also like

Download as pdf
Download as pdf
You are on page 1of 5
= ers (swseve) 1 Q How Positive Displacement Pumps Handle Viscosity Learn what can happen when you get viscosity calculations wrong. by Timothy Jones CIRCOR 05/07/2018 e006 As a volumetric fluid handling technology, two- and three-screw rotary positive displacement pumps create flow and are insensitive to system pressure changes. They deliver a nearly constant volume of liquid over a range of discharge pressures. This is why two- and three- screw pumps ate often the pump technology of choice for demanding hydrocarbon applications where flow or pressure demands change frequently, or even occasionally, on any given day, In designing a positive displacement pump for this application, one of the most important, but commonly overlooked, data inputs from users is detailed characteristics of their process fluid, Whether the specific fluid properties are proprietary, variable or just not known, this information must be determined and relayed to the manufacturer to ensure provision of a pump that will perform as desired in the specific application es —__ SD ° Image 1. Conducting fluid viscosity testing in Western Canada, a harsh setting, (Images courtesy of CIRCOR) Viscosity Calculation Is Vital The viscosity of a fluid is a key element in sizing and developing any pump, and the effects of viscosity on a positive displacement pump are much different than those on a centrifugal pump. The more viscous a fluid, the higher the flow rate will be for a positive displacement pump at a constant pressure and input speed—an advantage when handling heavy liquid hydrocarbons. For a user to ensure that they will receive a pump that will perform as desired in their application, specific detail on viscosity is critical. Ifa user is unsure of their fluid's viscosity range, it is recommended to send a fluid sample to a qualified lab for evaluation. One of the widely accepted methods used in determining a fuidss viscosity is ASTM Daas: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids. The time it takes for a volume of fluid to flow through a calibrated viscometer under a known pressure and temperature is measured, After recording twice at two different temperatures, the kinematic viscosity of the fluid can be calculated, With the kinematic viscosity known at two temperatures, ASTM D341: Standard Practice for Viscosity-Temperature Charts for Liquid Petroleum Products can be used to develop a plot of kinematic viscosity over a range, Using this chart, the viscosity of a fluid at any temperature in the associated range can be determined. In this process, off-design conditions such as startup should also be considered, as well as seasonal changes for applications that are affected by outdoor temperatures, For these and other reasons, it is acceptable to provide a range of viscosities that represent the fluid at varying conditions so the manufacturer can establish operating limitations where required. Image 2, Two-screw multiphase pumping system The Consequences of Inaccurate Data Sometimes data is provided to a manufacturer during the quotation phase, but it is incorrect or incomplete. This can have a major impact on the pump, the system or both. A positive displacement pump designed or selected for a fluid where the viscosity is lower than predicted will produce less flow than expected, Low flow may lead to reduced output in a crude cil pipeline, which translates into lower throughput per day, and ultimately a financial loss. In a lubricating system, the consequences of lower flow than predicted may lead to oil starvation of bearings. On the other hand, a pump that is selected for a fluid where viscosity is higher than predicted could also have negative impacts on a system. The higher flow produced by the disparity in viscosity will draw more power from an electric motor and could potentially trip the motor's protection circuit. In a lubricating oil system, excess flow that is dumped back to a holding tank can aerate the oil and increase its operating temperature. In extreme cases, the pump may not function properly due to inadequate suction pressure to fill the suction end pumping elements. This can lead to cavitation and excess vibration. Image 3. Another two- ew multiphase pumping system The Role of Testing & Data Correction Now that the manufacturer has the correct information to select or design a pump, more questions may arise from the user relative to a guarantee that this pump will perform once it is installed in their system. No two pumps are identical due to differences in the manufacturing process, so how can a manufacturer guarantee that a pump will perform in a user's specific application? With many variations in system fluids, pressures and driver speeds, a single manufacturer cannot be expected to be able to test to all possible operating conditions, This is where standard testing and data correction becomes critical. This step can instill confidence in a pumps performance before it ever reaches the end user's site. The process involves the following: A test fluid suitable for the pump is selected. With fluid sampling and calibration, along with temperature measurements, the viscosity of this test fluid is known. This allows the manufacturer to record detailed performance data at different operating conditions to develop a data set at this known viscosity. From standard testing, manufacturers can determine whether or not the output of the pump meets minimum requirements for performance. It may not be evident from the raw test data how the pump will perform in a specific application, but this information can then be corrected with th tions, including the user's fluid viscosity, and operating spoglsand pxes}eb gq information in hand, the manufacturer can estimate the input po as the efficiency of the pump under the user's conditions das we manufacturer can select or design a pump for the operating conditions that are provided by the user. How precisely those conditions are defined will determine how well the pump operates in the system. The more accurate and complete that information is, the better the chance that the product will operate with the desired results. Timothy Jones is a senior design engineer at CIRCOR. For more information, visit circorpt.com. Issue: May 2018 Topics i Kn als Bearings © Copyright Cahaba Magazine Events ia Group, Inc. A\ Subscribe Now! Enter your emi Newsletter Magazine Connect with Us e000 |, Privacy Policy

You might also like