PT.

Vale Indonesia, Tbk


NDT Inspection Report - Ultrasonic Thickness Test
Report: Job No.:
Project Name : Tabung Fire Extinguisher
Customer : Risk & Prevention
PMO / Notif : 202304709308 Drawing & Rev. No. :NA
Location : NDT Shop
Welding Process : NA
Type of Inspection : Ultrasonic Thickness Test
Material Spec. : C/S
Procedure of Inspection : ASME Sec V Standard Code of Acceptance Criteria : ASME VIII
UT Equipment Serial No. Probe Model Frequency Size Angle Beam Cable Type
Olympus 45 MG 60305311 D790 SM 5MHz 0.25" 0o Pan.LCMD 316 5B
Calibration Blocks : Step Block 2.5mm - 12.5mm
Examination Technique : Straight Beam Angle Beam
Inspection Units : Millimeters Inch
Velocity : 5921 mm/sec at 0o
Couplant : Glycerin Oil Grease Water Other
Probe Reference Surface
Scanning Level Test Range Amplitude level Original Thickness
Angle Level Condition
11.13 mm

Part Pic/Join No Thickness in (mm) Length Deep Remark/Result


Tabung Fire Extinguisher See Pict. Below See Pict. below For Support data only

5.0
5.1

4.0
1.5

1.6 1.5

1.7 1.5

1.5

Note: Silahkan di-compare dengan original Thicknessnya

Inspected by: NDT Manager: Customer:


MP & IR Pares Pabara Risk & Prevention

ASNT UT/MT/PT Level II ASNT UT/MT/PT Level II


Date : 16-Oct-2023 Date : 16-Oct-2023
16-02-2022 Date : 16-Oct-2023