Computer : IT-DESKTOP Run Tag : 0 Run Serial : 1 Operation : RUNNING ANALYSIS Load Case : Solving Linear Stiffness from Zero (unstressed) initial conditions THE STRUCTURE IS UNSTABLE OR ILL-CONDITIONED !! CHECK THE STRUCTURE CAREFULLY FOR: - INADEQUATE SUPPORT CONDITIONS, OR - ONE OR MORE INTERNAL MECHANISMS, OR - ZERO OR NEGATIVE STIFFNESS PROPERTIES, OR - EXTREMELY LARGE STIFFNESS PROPERTIES, OR - BUCKLING DUE TO P-DELTA OR GEOMETRIC NONLINEARITY, OR - A FREQUENCY SHIFT (IF ANY) ONTO A NATURAL FREQUENCY TO OBTAIN FURTHER INFORMATION: - USE THE STANDARD SOLVER, OR - RUN AN EIGEN ANALYSIS USING AUTO FREQUENCY SHIFTING (WITH ADDITIONAL MASS IF NEEDED) AND INVESTIGATE THE MODE SHAPES
*** Error Message 1 ***
Date & Time : 17/07/2023 8:12:47 PM Computer : IT-DESKTOP Run Tag : 0 Run Serial : 1 Operation : RUNNING ANALYSIS Load Case : RBG-SEQ FILE WRITE ERROR # -112. THE DISK MAY BE FULL, THERE MAY BE A SHARING CONFLICT, YOU MAY HAVE INSUFFICIENT RIGHTS, OR SOME OTHER ERROR MAY HAVE OCCURRED. FILE NAME = D:\20230717\etabs model\ M9156-RBG-XX-ZZ-M3-ST-00001_-_Rev_8_-_ET ABS_Ultimate_model_with_fixed_base.Y0A
*** Informational Message 1 ***
Date & Time : 17/07/2023 8:13:30 PM Computer : IT-DESKTOP Run Tag : 0 Run Serial : 1 Operation : RUNNING CASES IN SERIES Load Case : N/A TOTAL TIME FOR THIS ANALYSIS: 02:24:23
*** Informational Message 2 ***
Date & Time : 17/07/2023 8:14:16 PM Computer : IT-DESKTOP Run Tag : 0 Run Serial : 1 Operation : DELETING CASE RESULTS Load Case : EQ RESULTS DELETED.
*** Informational Message 3 ***
Date & Time : 17/07/2023 8:14:16 PM Computer : IT-DESKTOP Run Tag : 0 Run Serial : 1 Operation : DELETING CASE RESULTS Load Case : EQ-DRIFT RESULTS DELETED.
*** Warning Message 2 ***
Date & Time : 17/07/2023 8:16:51 PM Computer : IT-DESKTOP Run Tag : 0 Run Serial : 2 Operation : RUNNING ANALYSIS Load Case : Solving Linear Stiffness from Zero (unstressed) initial conditions THE STRUCTURE IS UNSTABLE OR ILL-CONDITIONED !! CHECK THE STRUCTURE CAREFULLY FOR: - INADEQUATE SUPPORT CONDITIONS, OR - ONE OR MORE INTERNAL MECHANISMS, OR - ZERO OR NEGATIVE STIFFNESS PROPERTIES, OR - EXTREMELY LARGE STIFFNESS PROPERTIES, OR - BUCKLING DUE TO P-DELTA OR GEOMETRIC NONLINEARITY, OR - A FREQUENCY SHIFT (IF ANY) ONTO A NATURAL FREQUENCY TO OBTAIN FURTHER INFORMATION: - USE THE STANDARD SOLVER, OR - RUN AN EIGEN ANALYSIS USING AUTO FREQUENCY SHIFTING (WITH ADDITIONAL MASS IF NEEDED) AND INVESTIGATE THE MODE SHAPES *** Informational Message 4 *** Date & Time : 17/07/2023 8:18:35 PM Computer : IT-DESKTOP Run Tag : 0 Run Serial : 2 Operation : RUNNING CASES IN SERIES Load Case : N/A TOTAL TIME FOR THIS ANALYSIS: 00:03:37