Electro-Steam Generator Corp.


50 Indel Avenue
P.O. Box 438
Rancocas, NJ 08073-0438
Phone: 866-617-0764
Fax: 609-288-9078
Toll Free: 866-617-0764
Email: sales@electrosteam.com

Item # S.S. DS-300 (H), 300 Kilowatt (kW) Double Stack High
Pressure 316L Stainless Steel Electric Steam Generator
Standard Features:
Built by an ASME Certificate holder in accordance with ASME BPVC Section
I - Rules for Construction of Power Boilers ("ASME BPVC Section I"). They also
comply with the requirements outlined in The National Board Synopsis of
Boiler and Pressure Vessel Laws, Rules and Regulations (NB-370) RULES FOR
CONSTRUCTION AND STAMPING section, which for many jurisdictions
include but are not limited to ASME BPVC Section I, ASME CSD-1, ASME B31.1,
and REGISTRATION WITH THE NATIONAL BOARD.

more

Specifications | Amperage | Dimensions | Minimum Clearance | Plumbing Connection Sizes | Included Options |
Options

Specifications

Brands Electro-Steam™
10/13/2023 | Page 2 of 6

Electrical Power Rating 300 kW (75 kW per Box) (4 Boxes)

208 V
230 V
Alternating Current (AC) 360 V
Voltage1 400 V
480 V
600 V

Phase 3

50 Hz
Frequency
60 Hz

Boiler Horse Power 30 bhp (15 bhp per Boiler)

1,035 lb/hr
Steam Capacity2
468.0 kg/hr

124.0 gal/hr
Average Water Consumption3
468.0 L/hr

Gross British Thermal Units


1,004,160 Btu/hr
(BTU) Output4

Maximum Boiler Pressure 100 psi

Operating Pressure 0 to 80 psi

Note for Operating Pressure Factory Set at 80 psi

Maximum Boiler Capacity 53 gal

Note for Maximum Boiler


26.5 Gallons per Boiler
Capacity

Boiler Fill Capacity 44 gal

Note for Boiler Fill Capacity 22.0 Gallons per Boiler

Boiler Material 5 316L Stainless Steel

Cabinet Material 316L Stainless Steel

Plumbing Material6 316L Stainless Steel


10/13/2023 | Page 3 of 6

American Society of Mechanical Engineers (ASME) - Boiler and


Pressure Vessel Code
Industry Standards American Society of Mechanical Engineers (ASME) - CSD-1
Canadian Underwriters Laboratories (cUL)
Underwriters Laboratories (UL)

Amperage

Amperage at 208 Volt (V)


Alternating Current (AC) Voltage 832.7 Amps (208.2 Amps per Box) (4 Boxes)
(3Ø Phase)

Amperage at 230 Volt (V)


Alternating Current (AC) Voltage 785.8 Amps (196.5 Amps per Box) (4 Boxes)
(3Ø Phase)

Amperage at 360 Volt (V)


Alternating Current (AC) Voltage 507.1 Amps (126.8 Amps per Box) (4 Boxes)
(3Ø Phase)

Amperage at 400 Volt (V)


Alternating Current (AC) Voltage 452.9 Amps (113.2 Amps per Box) (4 Boxes)
(3Ø Phase)

Amperage at 480 Volt (V)


Alternating Current (AC) Voltage 360.8 Amps (90.21 Amps per Box) (4 Boxes)
(3Ø Phase)

Amperage at 600 Volt (V)


Alternating Current (AC) Voltage 288.7 Amps (72.17 Amps per Box) (4 Boxes)
(3Ø Phase)

Dimensions

Length 64 in

Width 38 in

Height 63 in

Minimum Clearance
10/13/2023 | Page 4 of 6

Total Length 125 in

Total Width 60 in

Total Height 70 in

Plumbing Connection Sizes

Water Inlet (Shared) 1/2" NPT (Female) - Y-Strainer, Brass

Steam Outlet (Shared) 6" Flange (150 psi, 4-Hole) - 2-1/2" pipe connection

1-1/4" NPT (Male) (x2) - Two Black Pipes routed to the floor;
Safety Valves (x2)(Separate)
one from each Safety Valve.

Drain + MAFD Option (Shared) 1" NPT (Female) - Elbow, Brass

3/4" NPT (Female) - Threaded connection on the bottom of the


Steam Trap (Not Included)
2-1/2" shared Steam Outlet pipe.

Included Options

Two of these options are supplied standard in all double stack


steam generators; the motorized drain valve opens for three (3)
Motorized Automatic Flush and minutes during every start-up. As old water is drained out, fresh
Drain (MAFD) water is cycled in. This drain valve will not open if the pressure
in the steam generator exceeds 5 psi. The electric heaters are
locked out during flush cycle.

Two of these options are supplied standard in all double stack


steam generators; the Transformer steps down the primary
Single Service Transformer7 high voltage supplied for the heaters, in order to provide
120VAC 1Ø for the controls; with this option, only the two (2)
primary high voltage supplies are required.

Manual Low Water Reset trips if the electric heaters shut-off


Manual Low Water Reset8 because of a low water condition. Reset must be manually
pressed to resume steam production.

Two Water Feed Booster Pumps are supplied standard in all


high-pressure double stack steam generators. Each Water Feed
10/13/2023 | Page 5 of 6

Booster Pump increases the incoming water pressure to


Water Feed Booster Pump overcome the operating pressure of each steam generator. Each
Booster Pump requires a 5-150 psi water supply with a
minimum flow rate of 3 gpm (At least 6 gpm is required for
both)

Options

18-Month Warranty (12-Month Standard)


(2) Electric Heaters & (2) Heater Gaskets
Spare Parts Package Includes (2) Sight Glass Tubes & (4) Washers
(1) Pressure Control
(1) Contactor

2-stage, 5-micron water filter installed into incoming water line


5-Micron Water Filter to reduce sediment, dirt, rust, chlorine, and even odor from
incoming water supply.

1 Electro-Steam™ Double Stack electric steam generators are two (2) electric steam boilers stacked inside

one (1) cabinet. They are plumbed together, but not wired together. Double Stack steam generators require
two (2) or four (4) customer specific high voltage feeds, one (1) per Electrical Box - 150 kW models have two
(2) Electrical Boxes to feed and 200 to 480 kW models have four (4).
2 Calculated values are based off of a 212ºF boiler feed-water temperature. However, it must not exceed

140ºF. Temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated
values shown.
3 Calculated values are based off of a 212ºF boiler feed-water temperature. However, it must not exceed

140ºF. Temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated
values shown.
4 Calculated values are based off of a 212ºF boiler feed-water temperature. However, it must not exceed

140ºF. Temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated
values shown.
5 Wetted Surfaces.
6 Wetted Surfaces.
7 Two (2) Single Service Transformer options are included with each double stack electric steam generator.

These options provide 120 VAC 1Ø, 50/60 Hz for each boiler's controls.
8 A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this

Reset Button is required as per your local boiler codes, simply plug the two attached wires into the PC-Board
terminals labeled "Reset"
10/13/2023 | Page 6 of 6