Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Totally Integrated

Automation Portal

Baitap02 / PLC_1 [CPU 1214C DC/DC/DC] / Program blocks


Main [OB1]
Main Properties
General
Name Main Number 1 Type OB
Language LAD Numbering Automatic
Information
Title "Main Program Sweep Author Comment
(Cycle)"
Family Version 0.1 User-defined
ID

Main
Name Data type Default value Comment
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant

Network 1: Khoi Tao

%I0.0 %I0.1 %I0.2 %M1.1


"Start" "Stop" "EMG" "Run"

%M1.1
"Run"

Network 2: Trang thai Y1

%M1.1 %M1.3 %M1.4 %M1.5 %M1.6 %M1.7 %M1.2


"Run" "Y2" "Y3" "Y4" "Y5" "Y6" "Y1"

%M1.2
"Y1"

Network 3: Trang thai Y2


Totally Integrated
Automation Portal

%M1.2 %I0.4 %M1.4 %M1.3


"Y1" "a2" "Y3" "Y2"

%M1.3
"Y2"

Network 4: Trang thai Y3

%M1.3 %I0.6 %M1.5 %M1.4


"Y2" "b2" "Y4" "Y3"

%M1.4
"Y3"

Network 5: Trang thai Y4

%M1.4 %I1.0 %I0.4 %M1.6 %M1.5


"Y3" "c2" "a2" "Y5" "Y4"

%M1.5
"Y4"

Network 6: Trang thai Y5

%M1.5 %I0.5 %M1.7 %M1.6


"Y4" "b1" "Y6" "Y5"

%M1.6
"Y5"

Network 7: Trang thai Y6

%M1.6 %I0.7 %I0.6 %I0.3 %M1.7


"Y5" "c1" "b2" "a1" "Y6"

%M1.7
"Y6"
Totally Integrated
Automation Portal

Network 8: Tin hieu ra A

%M1.2 %Q0.0
"Y1" "A"

%M1.4
"Y3"

%M1.5
"Y4"

%M1.6
"Y5"

%M1.7 %I0.5
"Y6" "b1"

Network 9: Tin hieu ra B

%M1.3 %I0.3 %Q0.1


"Y2" "a1" "B"

%M1.4
"Y3"

%M1.6
"Y5"

Network 10: Tin hieu ra C

%M1.4 %Q0.2
"Y3" "C"

%M1.5
"Y4"

You might also like