Weather-guard Ultra

USAGE An exterior high quality emulsion paint based on an all acrylic resin
combined with an algaecide and fungicide. Suitable for use on most sound,
dry exterior masonry and rendering, including concrete, roughcast and
brickwork which are normally suitable for painting. Eg :- rustic or fair-faced
bricks.

Painting of parapet, free standing and retaining walls below ground level
damp-proof course is inadvisable. In these situations, it may be difficult to
prevent moisture penetration and consequent failure of the paint coating.
FEATURES A Durable Algae & Fungus Resistant Water based paint for exterior
masonry surfaces.
PACK SIZE 20Lt , 10Lt 4Lt & 1Lt
COLOUR RANGE Displayed on Colour Chart, special colours are made to order
TYPE OF FINISHING Mid Sheen

FILM PROPERTIES Chemical Resistance:


Resistant to mild atmospheric fumes, salt spray on new plaster and
brickwork.

Heat Resistance :
Not suitable for use on heated surfaces.

Water Resistance:
Resistant to the levels of atmospheric humidity normally experienced in
exterior environments.
COMPOSITION Pigment : Lightfast Non-Lead Pigments

Binder : Acrylic Emulsion and biocides

Solvent : Water

GLOSS LEVEL Mid Sheen


VOLUME SOLIDS Approx.40 - 45% by volume
VOC CONTENT Below 90gms/1litre
DENSITY 1.22 – 1.33 g/mL (depends on the colour)
POT LIFE N/A
SHELF LIFE 36 months
CURING TIMES 8 - 10 hours
TOUCH DRY 30 minutes
RECOAT DRY 6 hours
FULL CURE Overnight
FILM THICKNESS DRY 45 microns
FILM THICKNESS WET 91 microns
THEORETICAL 14-15 Sq.M /1litre (depending on surface)
COVERAGE
APPLICATION METHOD Brush, roller, conventional or airless spray.
SERVICE TEMPERATURE 10°C - 50°C
MIXING RATIO
N/A
INDUCTION
N/A
THINNING Brush Application
For normal use thinning should not exceed 1 part of clean water to 5 parts
of paint.

Conventional Spray
Add upto 1 part clean water to 2.5 parts of paint (40%).
Airless Spray Add upto 1 part clean water to 5 parts of paint (20%).
SPRAY Conventional Spray
RECOMMENDATION Satisfactory through most equipment.

Airless Spray
A typical set up for airless spray application would be a minimum working
pressure on paint of 133 bars (2000lb/sq.in.) with a spray tip size 0.38mm
(15 thou) and a spray tip angle 65°. Suggested pump capacity i s
5litres/minute minimum.
CLEANING UP Clean all equipment with clean water immediately after use.
SURFACE PREPARATION Cleaning :
Use a stiff scraper or high pressure water jetting thoroughly to remove any
loose or flaking material, mould or algae under strict supervision.

Mould & Algae :


To kill any residual growth, the affected areas should then be treated with
Multilac Disinfecting Wall Wash. Apply 1 coat with proper PPE (Personnel
Protective equipment) for safety measures. Apply using a worn brush and
leave for 24 - 48 hours, then wash, and scrub the surface with clean high
pressure water jet to remove bleach residuals and dead growth. In severe
cases, it may be necessary to repeat the treatment.

Removal of loosely bound materials :


Plastered surface need to be clean and dry. Use high pressure water
jetting to remove all loose paint and scale in order to build good adhesion
properties.

Repairs and making good :


Open out large cracks and defective paint film. Repair them with Multilac
Wall Putty mixed with Multilac Weather guard Flexible Elastomeric Wall
Primer in a ratio of 4:1 respectively. Repair minor / hairline cracks with
Multilac Weather guard Flexible Elastomeric Wall Primer and cure
overnight.

Stains and leakages :


Repair this source of any leaks and drips, which cause stains. Allow the
wall to dry out. If the stain reappears, use 2 coats of Multilac Supreme Life
Water Proofing Sealer (Solvent based) to seal the surface through and
leave it to dry for 24-48 hours.
DIRECTIONS FOR USE On absorbent surfaces, apply a thinned sealing coat of Weather guard
Masonry Paint. The normal finishing process is two full coats of Weather
guard Masonry Paint, but on previously painted surfaces in good condition,
where similar colour are used, one coat may be sufficient. Very slight
colour variation may occur between cans. When using several cans mix in
a large container to ensure colour uniformity.

Stir thoroughly before use.


FLASH POINT N/A
FREIGHT Paints (Water Based)
CLASSIFICATION
MSDS REFERENCE NO.

SAFETY, HEALTH AND * Keep container tightly closed and keep out of reach of children.
ENVIRONMENTAL * When applying paint it is advisable to wear suitable eye protection.
INFORMATION * In case of contact with eyes, rinse immediately with plenty of water and
seek medical advice.
* Remove splashes from skin: use soap and water or a recognised skin
cleaner.
* Ensure good ventilation during application and drying.
* Do not breathe vapour/spray.
* In case of insufficient ventilation during spraying wear suitable respiratory
equipment that meets an appropriate standard approved by the HSE.
* Care must be taken when transporting paint. Keep container in a secure
upright position, do not use or store by hanging on a hook.
* Contains no added lead.
* Protect from frost and extremes of temperature. Do not empty into drains
or watercourses.

For further information or if you have any concerns about using this product contact the Sales Department at the address below:

75/1, Wattalpola Road, Henamulla,


Panadura
Tel/Fax : +94 (011) 5556559

E-mail: projects@multilac.com

Any advice, recommendations, information, assistance or service provided by Macksons Paints Lanka (Pvt) Ltd. in relation to goods
manufactured, marketed is given in good faith. However, any advice, recommendations, information, assistance or service provided by
Macksons Paints Lanka (Pvt.) Ltd is provided without expressed or implied warranties.
18 th February 2012

You might also like