TMC UNIT USER’S MANUAL

<INDEX>
AA. TMC UNIT Drawing.
BB. Installing the Fluxgate sensor.
CC. Calibration/Deviation procedure.
DD. TMC Calibration/Deviation table.
EE. Dip switch setting.
ADJUSTING THE FLUXGATE(TM-42) (#2)
1. ADJUSTING THE SF-30(FLUXGATE) 2. DEVIATION ADJSUTMENT.

MUST INSTALL CONCUR WITH


#1 AND #2(SMALL HOLE).
AFTER INSTALLING THE SF-30 , INTIAL
DEVIATION OCCURS, PLEASE DO NOT
FASTENT THE BOLTS FIRMLY AND
SMALL HOLE - FRONT TURN THE SF-30 RIGHT OR LEFT SLIGHTLY
FOR CORRECTING THE COURSE(MINIMIZE
#1
DEVIATION BETWEEN MAGNETIC AND TM-42)
AFTER MINIMIZING OR SYNCHRONIZING
THE DEVIATION(normally less than 0.5~1.0degree)
#2
THEN FASTEN THE BOLT FIRMLY.
AFTER THAT, FOLLOW NEXT PAGE MANUAL FOR
FINE DEVIATION/CALIBRATION COURSE
FROM 1~9.9 DEGREE).

EASY TO INSTALL WHEN 2 CREWS ARE COOPERATE IN INSTALLING


- CREW(#1) AT MAGNETIC COMPASS : ADJUST/INSTALL THE SF-30(FLUXGATE)
- CREW(#2) AT BRIDGE : INFORM THE CURRENT COURSE OF TM-42 DISPLAYER TO CREW(#1) WHO IS INSTALLING
THE SF-30 FLUXGATE BY WALKIE TALKIE. WHEN CONCUR, CREW(#1) FASTEN THE SF-30 FIXING BOLTS FIRMLY.
TMC UNIT DEVIATION PROCEDURE(#3)

1 2 3

PRESS “DEV/CAL” BUTTON THE “CALu” WILL BE DISPLAYED. THE “CALd “WILL BE DISPLAYED.
CONTINUOUSLY MORE THAN PRESS SHORTLY 1TIME AGAIN PRESS SHORTLY “DEV/CAL”
3 SECOND(LONG TIME) FOR “CALd” BUTTON

•PRESS LONG TIME : 3 SECONDS


• PRESS SHOR TIME : 1SECOND
TMC UNIT DEVIATION PROCEDURE(#3-2)

4 5 6

IF YOU PRESS “DEV/CAL” SHORT


TIME, IT WILL PASS TO NEXT
“A 0” WILL BE DISPLAYED. THEN “0.0” WILL BE DISPLAYED. ADDRESS. “A010” to “A350”
THIS MEANS ADDRESS. YOU CAN ADD VALUE BY Which means, (000 ~360DEGREE).
(000 ~ 010 DEGREE). “DIM –” OR “DIM+” BUTTON. IF COMPLETED, PRESS LONGTIME
PRESS SHORT AGAIN. NOW “-4.4 DEGREE” ADDED FOR EXIT.

•PRESS LONG TIME : 3 SECONDS


• * PRESS SHOR TIME : 1SECOND
TMC UNIT DEVIATION PROCEDURE(#3-3/EXAMPLE)

210 Degree 209.7 Degree


After installing the SF-30(Fluxgate),
209.7 now we have difference. The TM-42 heading
should be added(deviation compensation)
which means, value should be added.

EX)TM-42 209.7 Degree + 0.3 Degree.

Then the heading of M.C and TM-42 will


be concur.
Magnetic compass TM-42

AA) PRESS “DEV/CAL” LONG TIME. THE SELECT “CALd” by “DIM +” BUTTON. THE PRESS SHORT
TIME TO ENTER A000 MODE THEN PRESS “DIM+ or “DIM-” button to go “A200”(200~210DEGREE)
BB) THEN PRESS “DEV/CAL” BUTTON SHORT TIME.
CC) THEN PRESS “DIM+” SHORT TIME AND ADD THE VALUE. “0.3”
DD) THEN PRESS LONG TIME TO EXIT THE MENU.
NOTICE : IF THE VALUE IS NOT ADDED, PLEASE ALSO TRY “A190” OR “A210”.

•PRESS LONG TIME : 3 SECONDS


• * PRESS SHOR TIME : 1SECOND
TMC UNIT DEVIATION/CALIBRATION TABLE
* Please proceed DEV/CAL by using(fill in) following table.
DIP SWITCH SETTING FOR TM-42 DISPLAY UNIT
•Most of the case, set the dip switch as before. Refer this page only when interface trouble
Additionally occurrs..

DEPARTMENT OF SERVICE(A/S)
ERROR MESSAGE/TROUBLESHOOTING

A. SYMPTOM :
i) “ErrF” - Installation stage : Possibly wrong connection.
- After delivery : Loose connection/defective SF-30(Fluxgate sensor).

Troubleshooting : Check the wiring/connection by referring the drawing.


Unplug and re-plug in the SF-30(Fluxgate sensor)

ii) Not feeding to Autopilot or other equipment


Troubleshooting : Check the dip switch setting.
* After dip switch changing, the TMC(TM-42) should be Reset.
(Just pressing power ON/OFF button is not reset. Completely cut off the power to TM-42
or Plug out the cable and Plug in is required)
Check the Status of receiving TMC(TM-42) NMEA SIGNAL equipment(such as AUTOPILOT/UDR)

iii) The TM-42 display Freeze certain heading.


Troubleshooting : Check the Magnetic compass card.
Unplug and re-plug in the SF-30(Fluxgate sensor)