Block B - O Mon Gas Pipeline Project

EPC Phase - Detailed Design

Data sheet No.: BB.G-VSP-PVE-ED-00-PI-DAS-007 Rev. 0 Sheet: 8 of 11


BLOCK B - O MON PIPELINE OPERATING COMPANY

Data Sheet for LIQUID TRAP, CLASS 150#


Tag No.: Note 4 Plant Location: O Mon GDC
Service: Utility Air Supplier: TBA
P & ID No.: Note 4 Purchase Order No.: TBA
Calculation Ref.: VTA No. of Units: TBA
Service Description :
GENERAL
1 Specialty Item Code SP6-150
2 Nominal Size (Inlet and Outlet): DN 50, Note 4, Note 8
3 Qty: Note 4, Note 8
4 Line Number Note 4
5 P&ID Number Note 4
DESIGN DATA
6 Piping Class / Specification 150# / C1A, Note 3
7 Type Free Float Type, VTA
8 Medium Type Water / Air
9 Medium State Liquid / Air
10 End Connection (Inlet and Outlet) RF Flange, ASME B16.5, 150#
11 Installation Position VTA
O
12 System Design Press. kPa(g) 1870 @ 38 C
O
13 System Design Temp. C -29/66
14 Drawing detail Note 5
MATERIAL (Note 6)
15 Material Pipe ASTM A106 Gr.B
16 Body/ Cover/ Cap ASTM A105 or A216 Gr.WCB or Equivalent
17 Weneck Flange ASTM A105
18 Float SS316, Ball Type, VTA
19 Orifice VTA
20 Screen / Mesh SS316
21 Gaskets Note 3
22 Bolts and nuts ASTM A193/B7 Studs & A194/2H nuts, Hot Dip Galvanized
MANUFACTURE & SHIPPING
23 Manufacture TBA
24 Model Number Vendor Catalogue
25 Shipping (Weight) (Kg) VTA
26 Operating (Weight) (Kg) VTA
EXTERNAL PROTECTION
27 Painting Yes, Note 7
28 To suit environment Above ground, outdoors
INSPECTION & TESTING
29 Hydrostatic Testing kPa(g) 2805
30 Leak test Manufacturer Standard
31 Radiography 100% For all weld
32 Third party inspection Yes
33 Material certification Yes
34 Visual examination Yes

Note :
1. VTA denotes vendor to advise, indicated information to be completed and supplied with supplier's quotation.
2. TBA : to be advised.
3. Refer to Doc. Number: BB.G-VSP-PVE-ED-00-PI-SPC-001 Piping Class Specification and Valve Code.
4. Refer to Doc. Number: BB.G-VSP-PVE-ED-00-PI-LST-002 Specialty Piping Items List.
5. Vendor shall furnish detailed cross sectional drawing with dimensions and specify suitable material of construction.
6. Vendor to verify that nominated materials are suitable for the specify water/ air.
7. Refer to Doc. Number: BB.G-VSP-PVE-ED-60-CR-SPC-009 Specification for Onshore Painting.
8. Refer to Doc. Number: BB.G-VSP-PVE-ED-00-PI-MTO-002 MTO for Specialty Piping Items
9. Liqiud trap shall be tagged as per tag number specified with SS316 tag plates and marked flow direction.

You might also like