DEVELOPMENT OF SIX LANE EASTERN PERIPHERAL EXPRESSWAY (NH NO.

NE-II) ON EPC MODE


PROJECT: PACKAGE-II FROM KM 0.00 TO KM 22.00 KUNDLI-GAZIABAD-PALWAL

Safe Bearing Capacity Calculations-19+900


As per IS 6403-1981
Maximum Design Section = 8m

Load consider in RS wall DL = 13.5 kN/m2


LL = 26 kN/m2
Block width B = 6.9 m
Eccentricity e = 0.64 m.
Effective width B-2e = 5.62 (As per BS-8006)

Water Table depth from G. L. = 0 m.


Water Table correction factor W' = 0.50
2
Pressure at base of wall= 257.7 kN/m
Required q safe = 25.77 t/m2

Following are the shear parameter of the soil of the top layer (from VUP 19+905,BH 01)
C = 65 kN/m2
f = 10 Degree
g = 17 kN/m3
Df = 1 m

For f = 10 Degree Nc = 8.34


Nq = 2.5
Ng = 1.2
Calculation of SBC
Depth Factor
dc =1+ 0.2(Df/B)(Nø)1/2 dq = dγ=1 for Ø <100 dq = dγ = 1+0.1(Df/B)(Nø)1/2 for Ø>100
= 1.0424 = 1.0212
Shape Factor
Sc = Sq = Sγ = 1 (For Strip Footing)

Inclination Factor
ic = iq = iγ = 1 (For vertical Wall)

q Ult = C NcScdcic + q NqSqdqiq + 0.5 g B' NgSγdγiγ W' (As per IS 6403:1981)

2
= 616.74 kN/m
3
q safe = 308.4 kN/m ( FOS=2.0)
30.8 t/m2 > Required q safe Safe