Standard Operating Procedure (SOP)

Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision


Category/Type: Domestic Genset 01

Installation of SEDEMAC Actuator L8.9- 250kVA


Objective:

Installation of SEDEMAC Acuator inplace of Wood ward Acuator keeping control panel,engine haress
same with adding Retrofit Harness.

Euipments/Items:

Instructions: Before SEDEMAC Acuator Assembly


1. Battery +ve & -ve terminal are removed from Battery.
2. Utility supply is in OFF condition in case of AMF application.

Procedure: Assembly
1. Ensure control panel EMG push button is in pressed/ locked position for local as well as remote
EMG.
2. Remove the battery terminal connection from battery: +ve & -ve battery cables.
3. Once battery connections are removed controller will be in OFF mode.
4. Remove Existence Actuator harness connections connected with Woodward Actuator & Remove
Actuator from Engine FIP.

Page 1 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

5. Take SEDEMAC Actuator Mounting bracket as shown & mount actuator on top side.

Bracket mounting
locations on Engine

6. Mount SEDEMAC Actuator on Bracket using Capscrew (4Qty.) as shown.

Note: Please ensure Actuator Part No. sticker in Top on mounting location as shown below.

SEDEMAC
Sticker & details

Page 2 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

7. Tighten Actuator 4 Qty. Mounting Capscrew using 10-11mm open spanner / 10mm Box socket.
Apply Torque 8 ± 1 N-m using torque tool & yellow mark after torqueing.

Apply both side Torque


8 ± 1 N-m using 10mm
socket.

8. Actuator comes from supplier with Linkage Length seating & assembly as shown

Note : Do not tight & distrub linkage Capscrew, Its CD Finalize with 128 ± 3mm from supplier end,
just please check & ensure using scale .

Page 3 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

9. Completed SEDEMAC Actuator Sub assembly with bracket as below:

Page 4 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

10. Fuel Injection Pump (FIP) Linkage setting:


a) FIP linkage along with Hardware (Capscrew, washer , Nut etc.)
b) FIP linkage Center distance (CD) approximate 128 ± 3mm mm & tighten the linkage nuts
(1nos. as shown in below) by using 10-11mm open spanner.

Nuts after adjusting of 128 ±


3mm distance.

Engine FIP C Linkage


mounting location/side.

11. SEDEMAC Actuator mounting assembly mount on Engine Cylinder block:


a) Please check & ensure removed Existence Wood ward Actuator.
b) Collect sub assembled SEDEMAC actuator with mounting bracket.

Page 5 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

c) Take & Mount SEDEMAC Actuator sub-assembly on engine block on 2 mounting holes as
below

SEDEMAC Actuator
mounting Bracket 2 locations
on Cylinder block

d) Tighten mounting Bracket Capscrew -2nos.using 16-17mm spanner & 16mm socket, Apply
Torque 52 ± 5 N-m., Yellow mark after torqueing.

SEDEMAC Actuator Bracket


mounting locations on Cylinder
block

Page 6 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

12. FIP & SEDEMAC Actuator Linkage assembly:

a) C linkage assembly as shown with FIP Lever .

SEDEMAC Actuator C Linkag


fitment with FIP Lever

b) Connect Actuator linkage to FIP ‘C’ type lever (inside) using mounting Capscrew-1 Qty. as
shown.

Actuator Linkage
connect with Engine
FIP ‘C’ lever.

Page 7 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

c) Tighten FIP lever mounting Capscrew -1 Nos. using 10-11mm open spanner
d) Connect Actautor Retrofit Harness Connection to SEDEMAC Acuator by using Connector .

Connect Engine harness


to SEDEMAC

e) Reconfirm once again the final assembly of an actuator as per instruction.

Note : A) Battery supply to ECU to be given directly through fuse.(ECU pin number 1(+) and 2)(-ve)

B) Stop signal to ecu pin number 10 to be routed through FSO relay.

Assembly Installtion Drawing :

Page 8 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

Installation Part List :

Level Part No. Description Qty


1 A062G072 INSTALLATION,ACTUATOR 1
2 A061H789 BRACKET 1
3 A059D621 ACTUATOR 1
4 A061H783 SPACER 2
5 A061K374 LINK,THROTTLE 1
6 A061H781 LINK,THROTTLE 1
7 A061H785 SPACER 1
8 A061H793 LINK,DRIVE 1
9 A059E101 BEARING,MAIN 2
10 0860-2127-09 NUT,HEX 2
11 A061H791 BEARING,CONNECTING ROD 1
12 A061H787 LINK,THROTTLE 1
13 0800-6494-12 SCREW,HEX HEAD 2
14 0850-2114-05 WASHER,LOCK 5
15 0800-6494-23 SCREW,HEX HEAD 1
16 0870-2322-04 NUT,LOCK 3
17 0860-2127-09 NUT,HEX 1
18 0800-6494-13 SCREW,HEX HEAD 1
19 0526-2403-24 WASHER,FLAT 1
20 0800-6520-38 SCREW,HEX FLANGE HEAD 2
21 0800-6520-10 SCREW,HEX FLANGE HEAD 4
22 A050R161 KIT,GOVERNOR 1
23 0800-6520-02 SCREW,HEX FLANGE HEAD 4
24 A048L463 SENSOR,MAGNETIC PICKUP 1
25 A062M796 Retrofit harness for 1.1 1

Page 9 of 10
Standard Operating Procedure (SOP)
Name: Installation SEDEMAC Actuator replacing of Woodward on L8.9_ 250kVA Revision
Category/Type: Domestic Genset 01

Retrofit Harness Drawing on for Field PC1.1 :

Revision History:

Revision Description Date Author


01 Initial Revision 05/03/2019 Vijay Kumbhar

Page 10 of 10