ZN Nhom 2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Method: Zn 19.09.

2023 Page 1 Date: 9/19/2023 1:58:44 PM

====================================================================================================
Sequence No.: 40 Autosampler Location:
Sample ID: blank Date Collected: 9/19/2023 1:56:44 PM
Analyst: Data Type: Original

----------------------------------------------------------------------------------------------------
Replicate Data: blank Analyte: Zn 213.86
Repl SampleConc StndConc BlnkCorr Time Signal
# mg/L mg/L Signal Stored
1 [0.00] 0.918 1:56:46 PM No
2 [0.00] 0.920 1:56:50 PM No
3 [0.00] 0.922 1:56:54 PM No
Mean: [0.00] 0.920
SD: 0.0000 0.0021
%RSD: 0.00% 0.23
Auto-zero performed.

====================================================================================================
Sequence No.: 41 Autosampler Location:
Sample ID: chuan 1 Date Collected: 9/19/2023 1:57:02 PM
Analyst: Data Type: Original

----------------------------------------------------------------------------------------------------
Replicate Data: chuan 1 Analyte: Zn 213.86
Repl SampleConc StndConc BlnkCorr Time Signal
# mg/L mg/L Signal Stored
1 [0.2] 0.032 1:57:02 PM No
2 [0.2] 0.034 1:57:07 PM No
3 [0.2] 0.029 1:57:11 PM No
Mean: [0.2] 0.032
SD: 0.000 0.0021
%RSD: 0.00% 6.67
Standard number 1 applied. [0.2]
Correlation Coef.: 0.961560 Slope: 0.21941 Intercept: 0.00000
S-shaped calibration curve detected. Two-coefficient equation used.

====================================================================================================
Sequence No.: 42 Autosampler Location:
Sample ID: chuan 2 Date Collected: 9/19/2023 1:57:19 PM
Analyst: Data Type: Original

----------------------------------------------------------------------------------------------------
Replicate Data: chuan 2 Analyte: Zn 213.86
Repl SampleConc StndConc BlnkCorr Time Signal
# mg/L mg/L Signal Stored
1 [0.4] 0.067 1:57:20 PM No
2 [0.4] 0.076 1:57:25 PM No
3 [0.4] 0.070 1:57:29 PM No
Mean: [0.4] 0.071
SD: 0.000 0.0045
%RSD: 0.00% 6.39
Standard number 2 applied. [0.4]
Correlation Coef.: 0.986818 Slope: 0.14413 Intercept: 0.00000
S-shaped calibration curve detected. Two-coefficient equation used.

====================================================================================================
Sequence No.: 43 Autosampler Location:
Method: Zn 19.09.2023 Page 2 Date: 9/19/2023 1:58:44 PM

Sample ID: chuan 3 Date Collected: 9/19/2023 1:57:36 PM


Analyst: Data Type: Original

----------------------------------------------------------------------------------------------------
Replicate Data: chuan 3 Analyte: Zn 213.86
Repl SampleConc StndConc BlnkCorr Time Signal
# mg/L mg/L Signal Stored
1 [0.6] 0.097 1:57:36 PM No
2 [0.6] 0.106 1:57:40 PM No
3 [0.6] 0.103 1:57:45 PM No
Mean: [0.6] 0.102
SD: 0.000 0.0048
%RSD: 0.00% 4.71
Standard number 3 applied. [0.6]
Correlation Coef.: 0.987205 Slope: 0.13611 Intercept: 0.00000
Check fit carefully. 2-coefficient curve used because 3-coefficient rolls over.

====================================================================================================
Sequence No.: 44 Autosampler Location:
Sample ID: chuan 4 Date Collected: 9/19/2023 1:57:53 PM
Analyst: Data Type: Original

----------------------------------------------------------------------------------------------------
Replicate Data: chuan 4 Analyte: Zn 213.86
Repl SampleConc StndConc BlnkCorr Time Signal
# mg/L mg/L Signal Stored
1 [0.8] 0.211 1:57:55 PM No
2 [0.8] 0.218 1:57:59 PM No
3 [0.8] 0.215 1:58:03 PM No
Mean: [0.8] 0.215
SD: 0.000 0.0037
%RSD: 0.00% 1.73
Standard number 4 applied. [0.8]
Correlation Coef.: 0.984855 Slope: 0.13305 Intercept: 0.00000
Check fit carefully. 2-coefficient curve used because 3-coefficient rolls over.

----------------------------------------------------------------------------------------------------
Calibration data for Zn 213.86 Equation: Nonlinear Through Zero
Entered Calculated
Mean Signal Conc. Conc. Standard
ID (Abs) mg/L mg/L Deviation %RSD
blank 0.000 0 0.000 0.00 0.23
chuan 1 0.032 0.2 0.208 0.00 6.67
chuan 2 0.071 0.4 0.406 0.00 6.39
chuan 3 0.102 0.6 0.529 0.00 4.71
chuan 4 0.215 0.8 0.828 0.00 1.73
Correlation Coef.: 0.984855 Slope: 0.13305 Intercept: 0.00000

====================================================================================================
Sequence No.: 45 Autosampler Location:
Sample ID: nhom 2 Date Collected: 9/19/2023 1:58:17 PM
Analyst: Data Type: Original

----------------------------------------------------------------------------------------------------
Replicate Data: nhom 2 Analyte: Zn 213.86
Repl SampleConc StndConc BlnkCorr Time Signal
# mg/L mg/L Signal Stored
1 0.197 0.197 0.030 1:58:17 PM No
Method: Zn 19.09.2023 Page 3 Date: 9/19/2023 1:58:44 PM

2 0.237 0.237 0.037 1:58:22 PM No


3 0.263 0.263 0.041 1:58:26 PM No
Mean: 0.232 0.232 0.036
SD: 0.0331 0.0331 0.0059
%RSD: 14.24% 14.24% 16.38