Anyagvizsgáló és Minőségellenőrző ZRt

1211 Budapest, Központi út 24-26. Telephone: 276-8945, 278-0757 Telefax: 276-8650


E-mail: agmivig@agmi.hu

Mechanical Testing and Analytical Laboratory

Project manager: Date: November 9, 2010


Telephone: Test number:
Job Number:

TEST REPORT

Entrustee:

Study: Analytical test of 1 pc ME-109 G marked main spar

The analytical testing of 1 pc of main spar labelled as ME-109 G, performed in our laboratory based on the
order dated on November 4, 2010.

By considering the instructions in brackets, the content of C and S samples was tested based on the infrared
absorption method, by high-frequency furnace burning (HSZA 01-4:1996), the P content was tested based
on alkaline acidimetric volumetric analysis (HSZA 01-3:1996), and the other elements were tested by
emission spectrometry method (HSZA 01-1:1996).

The identity of the sample and the test results were summarized in a table.
Table No.1
Sample Chemical composition %
indicator C Si Mn S P Cu Cr
ME-109 G 0.34 0.26 0.36 0.005 0.010 0.22 1.92

Table No.1 continued


Sample Chemical composition %
indicator Ni Nb V Ti Mo A1
ME-109 G 1.92 < 0.01 0.02 < 0.01 0.37 0.04

Designated material quality based on the chemical composition and specified standards: 1.6604
(30CrNiMo8).

Head of Laboratory Project Manager


A testing laboratory accredited by the NAT under the NAT-1-1132/2010 number

This report may not be reproduced in detail! NNA = A test procedure not accredited by the NAT Conclusions and expertise drawn
from the results fall outside of the NAT accreditation
Anyagvizsgáló és Minőségellenőrző ZRt
1211 Budapest, Központi út 24-26. Telephone: 276-8945, 278-0757 Telefax: 276-8650
E-mail: agmivig@agmi.hu

Mechanical Testing and Analytical Laboratory

Project manager: Date September 22, 2011


Telephone: Test number:
Job Number:

TEST REPORT

Entrustee:

Study: Tensile testing of 2 pieces of material labelled ME109 and BÜ-131

The tensile testing of 2 pcs of material sample labelled as ME109 and BÜ-131 respectively,
performed in our laboratory based on the order dated on September 19, 2011.

Tensile testing

For the tensile testing of the samples we formed 1 - 1 pcs of longitudinal and cylindrical body
blocks. The test results are summarized in Table No. 1.

Table No.1
Designation Body block Yield point Tensile Elongation at Contraction
diameter strength break
Rp0,2 Rm N/mm2 A% Z
mm N/mm2 %

ME109 10.00 1170 1306 12.5 52.4


BÜ-131 10.00 863 1073 12.5 59.0

Head of Laboratory Material Testing Technician

A testing laboratory accredited by the NAT under the NAT-1-1132/2010 number

This report may not be reproduced in detail!


NNANNA = A test procedure not accredited by the NAT
Conclusions and expertise drawn from the results fall outside of the NAT accreditation