Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

SOM Ver. 1.

0
Section 10 GP MARITIME PRIVATE LIMITED
Rev: 0.0
15.07.2023 MAIN ENGINE PMS SOM 10.1 C

VESSEL

TOTAL M/E RUNNING HOURS:- PORT /STBD

RUNNING HOURS FOR MONTH:- Month / Year:

COMPONENTS & MAINTENANCE HOURS FREQUENCY CYL.1 CYL.2 CYL.3 CYL.4 CYL.5 CYL.6 CYL.7 CYL.8
Cylinder Cover
Last Done / date-hrs 8000-10000
Fuel valve
Last Done / date-hrs 2000
Starting valve
Last Done / date-hrs 8000
Exhoust Valve
Last Done / date-hrs 2000-3000
Inlet Valve
Last Done / date-hrs 4000-6000
Safety valve
Last Done / date-hrs 8000
Tappet
Last Done / date-hrs 2000
Piston
Last Done / date-hrs 8000-10000
Cylinder Liner
Last Done / date-hrs 8000-10000
Fuel pump timing
Last Done / date-hrs 8000
Fuel Pump overhaul
Last Done / date-hrs 8000
Crank shaft deflection
Last Done / date-hrs 3000
Crank case inspection
Last Done / date-hrs 1000
Main Brg wear down
Last Done / date-hrs 4000
Camshaft Inspection
Last Done / date-hrs 4000
Governor oil renew
Last Done / date-hrs 1000
Foundation bolts
Last Done 3 months

1 of 2
FF0000This document is strictly CONTROLLED and part of the company SMS. Once printed, scanned or photocopied will be deemed as UNCONTROLLED
Turbo Charger PMS

VESSEL

TOTAL M/E RUNNING HOURS:- PORT /STBD

RUNNING HOURS FOR MONTH:- Month / Year:

COMPONENTS & MAINTENANCE HOUFREQUENCY


Air Filter Cleaning
Last Done / date-hrs 500
Oil Renewal
Last Done / date-hrs 2000
Overhaul(Rotor Cleaning)
Last Done / date-hrs 8000
Bearing Renewal turbine side
Last Done / date-hrs 16000
Bearing Renewal blower side
Last Done / date-hrs 16000

MISC
Air Cooler - Air side
Last Done / date-hrs 3000
Air Cooler - water side(FW)
Last Done 12 months
Jacket Cooling Water Tank Cleaning
Last Done 12 months
L.O. Analysis
Last Done 3 months
Oil Mist detector
Last Done / date-hrs 3000
Foundations Check
Last Done 3 months
Manoevring Linkages Lubrication
Last Done 3 months
Reduction Gear Inspection
Last Done / date-hrs 8000
Pneumatic System Filters
Last Done 6 months
Emergency Manoevring test
Last Done 3 months

2 of 2
FF0000This document is strictly CONTROLLED and part of the company SMS. Once printed, scanned or photocopied will be deemed as UNCONTROLLED

You might also like