Stoichiometry Application Week14 App11 21.12.2022

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

21.12.

2022

BIE 2115 Stochiometry - Application 11


Q1- The weather report is declareted for the students who take stoichiometry lecture in MCBU Muradiye
Campus that the temperature is approximately 13°C and the relative humidity is 47%. It is expected
for students to calculate below questions by using psychrometric chart.
1- What is the absolute humidity of the air?

a) 0.0042 kg/kg DA b) 0.0040 kg/kg DA c) 0.0046 kg/kg DA d) 0.0050 kg/kg DA e) 0.0052 kg/kg DA

2- What is the humid (specific) volume of the air?


a) 0.82 m3/kg DA b) 0.81 m3/kg DA c) 0.80 m3/kg DA d) 0.85 m3/kg DA e) 0.79 m3/kg DA

3- What is the enthalpy at saturation of the air?


a) 25 kJ/kg DA b) 25 kJ/kg DA c) 25 kJ /kg DA d) 25 kJ /kg DA e) 25 kJ /kg DA

4- What is the enthalpy deviation of the air?


a) -0.05 kJ/kg DA b) -0.075 kJ/kg DA c) -0.10 kJ /kg DA d) -0.125 kJ /kg DA e) -0.15 kJ /kg DA

5- What is the specific enthalpy of the air?


a) 24.825 kJ/kg DA b) 24.925 kJ/kg DA c) 25.075 kJ /kg DA d) 25.125 kJ /kg DA e) 24.975 kJ /kg DA

6- What is the wet-bulb temperature of the air?

a) 8°C b) 7.5°C c) 13°C d) 8.5°C e) 9°C

7- What is the dew-point temperature of the air?

a) 2.2°C b) 2°C c) 3°C d) 3.5°C e) 5°C

If absolute humidity was measure as 0.0055 kg water/kg at 13°C for today;

8- What would be the relative humidity?

a) 47% b) 55% c) 59% d) 60% e) 61%

9- What would be the humid (specific) volume?


a) 0.825 m3/kg DA b) 0.810 m3/kg DA c) 0.800 m3/kg DA d) 0.850 m3/kg DA e) 0.795 m3/kg DA

10- What would be the enthalpy at saturation?


a) 27 kJ/kg DA b) 25.5 kJ/kg DA c) 27.2 kJ /kg DA d) 28 kJ /kg DA e) 30 kJ /kg DA

11- What is the enthalpy deviation of the air?


a) -0.05 kJ/kg DA b) -0.07 kJ/kg DA c) -0.10 kJ /kg DA d) -0.12 kJ /kg DA e) -0.15 kJ /kg DA

12- What is the specific enthalpy of the air?


a) 27.13 kJ/kg DA b) 27.27 kJ/kg DA c) 25.13 kJ /kg DA d) 25.27 kJ /kg DA e) 24.97 kJ /kg DA

13- What would be the wet-bulb temperature?

a) 8°C b) 7.5°C c) 13°C d) 8.5°C e) 9°C

14- What would be the dew-point temperature?

a) 2.2°C b) 2°C c) 3°C d) 3.5°C e) 5°C


21.12.2022

Q2- The moist air is maintained in a 2-L system at 40 °C. The system is left to cool. When the temperature
reaches 20 °C, drops of moisture begin to form on the system wall. Considering that the pressure is
1 atm throughout the process, answer;
1- What is the relative humidity?
a) 30% b) 32% c) 35% d) 38% e) 40%

2- What is the absolute humidity of the air?


a) 0.0142 kg/kg DA b) 0.0140 kg/kg DA c) 0.0148 kg/kg DA d) 0.0150 kg/kg DA e) 0.0152 kg/kg DA

3- What is the wet-bulb temperature of the air?

a) 25°C b) 25.1°C c) 25.5°C d) 26°C e) 26.1°C

4- What is the humid (specific) volume of the air?


a) 0.90 m3/kg DA b) 0.91 m3/kg DA c) 0.94 m3/kg DA d) 0.95 m3/kg DA e) 0.89 m3/kg DA

5- What is the specific enthalpy of the air at 40°C?


a) 80.00 kJ/kg DA b) 79.65 kJ/kg DA c) 78.35 kJ /kg DA d) 78.00 kJ /kg DA e) 77.65 kJ /kg DA

6- What is the specific enthalpy of the air at 20°C?


a) 80.00 kJ/kg DA b) 79.65 kJ/kg DA c) 78.35 kJ /kg DA d) 78.00 kJ /kg DA e) 77.65 kJ /kg DA

7- What is mass of the dry air (g)?


a) 2.0 g b) 2.2 g c) 2.4 g d) 2.6 g e) 2.8 g

8- What is mass of the water (g)?


a) 0.033 g b) 0.039 g c) 0.043 g d) 0.049 g e) 0.053 g

9- What is enthalpy change in joules of the cooling dry air from 40 °C to 20 °C?

a) 40 J b) 44 J c) 50 J d) 55 J e) 64 J
21.12.2022

Q3- It is desired to dry a wet product by passing it through a continuous dryer. Hot air is used for this
drying process. The hot dry air which enters the dryer at a speed of 400 kg/min contacts the wet
product to take the water from the product. The humid air exits the dryer at 50°C containing 2.44%
water vapor by weight. After dryer, water enters the condenser unit to cool the air to 10°C. The
pressure is constant at 1 atm throughout the system.
1- What is the mass flow rate (kg/min) of humid air (HA) removing from dryer?
a) 390 kg HA/min b) 400 kg HA/min c) 410 kg HA/min d) 420 kg HA/min e) 430 kg HA/min

2- What is the mass flow rate (kg/min) of water removing from dryer?
a) 10 kg water/min b) 15 kg water/min c) 20 kg water/min d) 25 kg water/min e) 30 kg water/min

3- What is the absolute humidity of humid air removing from dryer?


a) 0.020 kg/kg DA b) 0.024 kg/kg DA c) 0.025 kg/kg DA d) 0.027 kg/kg DA e) 0.030 kg/kg DA

4- What is the wet-bulb temperature of the air removing from dryer?


a) 30°C b) 31.5°C c) 31°C d) 35°C e) 32.8°C

5- What is the dew-point temperature of the air removing from dryer?

6- a) 28°C b) 28.5°C c) 29°C d) 29.5°C e) 30.0°C

7- What is the the relative humidity removing from dryer?


a) 30% b) 32% c) 35% d) 38% e) 40%

8- What is the the humid (specific) volume removing from dryer?


a) 0.945 m3/kg DA b) 0.948 m3/kg DA c) 0.950 m3/kg DA d) 0.952 m3/kg DA e) 1.000 m3/kg DA

9- What is the specific enthalpy of the air removing from dryer?


a) 114.00 kJ/kg DA b)114.95 kJ/kg DA c) 115.00 kJ /kg DA d) 115.95 kJ /kg DA e) 116.05 kJ /kg DA

10- What is the the relative humidity leaving from the condenser?
a) 85% b) 80% c) 95% d) 90% e) 100%

11- What is the the absolute humidity leaving from the condenser?
a) 0.008 kg/kg DA b) 0.077 kg/kg DA c) 0.072 kg/kg DA d) 0.007 kg/kg DA e) 0.068 kg/kg DA

12- What is the the condensation rate of water from the condenser?
a) 10 kg water/min b) 8.08 kg water/min c) 7.92 kg water/min d) 6.92 kg water/min e) 6.08 kg water/min

You might also like