20180313012904295

You might also like

Download as pdf
Download as pdf
You are on page 1of 12
iO] ms a CH IANS SREIRS PR A FAR EAST FIRST NEW ENERGY CO. .LTD SCPE ITT / SEB / fe EB i 2 tii O se O tee SEB PST 18650-2560 P=Ai Hats RIK Wek 4/00 SRS PS-RD-O15 BRR aK 4/00 a: HSE BR BHLIT AM 2017/8/22 SsiapearT HATRED RA ABA lara sie: aus O wax Ona Seay (Oeese |Omary [Oasee | Ceae [aeone | Game | Bante BRS OL 02 03 4 08 REA BRAM 1 fea [Oaere [Cee Owes eas BRS 09 10 02 03 BEA amore | 1 Pree pce eae S TE de ALERT — PLP LEG A= ‘et. or-soest/901-01-01/02 a Edition: A/00 EAB ESET SARS U NGM Wemrperrber COO |ireereet Nimnter S9SEC SeEe G~ aE TRIBE] Number: PS-RD-015 = BF a Specification For Lithium-ion Rechargeable Cell HUSA : 18650-2500mAh Cell Type: 18650-2500mAh Document No ] PS-RD-015 Version change date | 201 aS Version A/00 Pages | i Designed Checked Approved BI VY za. 08-22 AIR i (2 mansesemaman [Niner Ds FAR EAST FIRST NEW ENERGY CO.,LTD ert 1/0 Contents Ha 1 Preface Wi 2 Definition 2X 2.1 Rated capacity and minimum capacity ise 4: sii. #e 2.2 Standard charge method RHEE 3% 2.3 Standard discharge method rte fic rl, J xt 3 Cell type, barcode , Colours, Bit 3.1 Deseription and model Hats is8w} 38143 3.2. Cell colour explanation +; 3558 £7 18.591 4 Characteristics 7H tE HE 4.1 Cell specification asa 42 Cell dimensions 27} $ Technical requirements ${RSER 5.1 Cell storage conditions iS 47AR ERNE 5.2 Cell testing conditions a5 Wat AF 5.3 Requirement of the testing equipment iW) B(X2 5.4 Electronic performance Ht fit 55 Safety characteristics 22H ‘Warning and cautions in handling the lithium-ion cell Fit 955 380 9 ee West ‘The restriction of the use of hazardous substances #24) i 2 fi] BR Contact information RAZR 9 Version history 20% ea a ‘Ts spec manual isthe enterprise standard of FS, without authorization any pate or culation fe pronbled.Pagel/N0 (5 memememen OS FAR EAST FIRST NEW ENERGY CO. .LTD Page: 2/10 1 Preface #12 ‘This specification describes the type and dimensions, performance, technical characteristics, warning and caution of the lithium ion rechargeable cell. The specification only applies to 18650 cell supplied by Far East First New Energy Co., Lid. Zep AR TRUST ASU. AE, BORER EERO, RARE ACNE AE ARS HIE PHBE 18650 EFS. 2 Definition =X 2.1 Rated capacity and minimum capacity: PEERSRAAR, Rated capacity: Cap=2500mAh, minimum capacity: Cap=24S0mAh. Under 252°C, It means the capacity value of being discharged by 2-hours rate to end voltage 2.5 V, which is signed Cap, the unit is mAh. AREKEA Cap-2500mAh, HAVER Cap=2a50mAh, 4246 25=2° CHEF, DL 2 AME RACH ME BLK 2.5: V LAUER, DL Cap Zea, MR Ay RHEE (MAN). 2.2 Standard charge method: REBAR: Under 2542°C, it can be charged to 4.20V with constant current of 0.51, (A), and then, charged continuously with constant voltage of 4.2V until the charged current is 0.021, (A) Hide 3+ 2CHIEK. VL 0.51, (A BTEILTE LEM ERE EE 4.20 Va, HONTEIR 4.20V Je, EFM EME 0.021, (A) A. PPL FEH. 2.3. Standard discharge method: RHE: Under 252°C, it can be discharged to the voltage of 2.5V with constant current of 0. 51, (A). HE 2522 CHM, 010.51, (\) TLE bE 2.5 Ve 3 Cell type and Colour "HS, Hits 34 Description and model STARS Description: Cylindrical Li-ion rechargeable cell Model: 18650-2500mAh WH: EF — kes WS: 18650-2500mAh 3.2 Cell colour explanation F852 Bit 325A Purple HE Coloris for reference only, the colour canbe adjusted according to customer requirements, PERKS, TTR A BORAT ME. 4 Characteristics HiihtERE 4.1 Cell specification aH ITEM SPECIFICATION ae at Rated capacity ‘Wie et 2500 mAh@O.SC Minimum capacity Bhat 2450 mAh@0.5C Normal voltage aA ory ie Energy density 319 Wh/L L fe 188 Wh/kg ‘This spec manval isthe enterprise standard of FST, without authorization, any pate or Greulaon le prohibited. Paged/10 ne = + PS-RD-15 ~ G S eR SARIS) ‘A100 WD cacy ter ae ean ae 420 005v 2 aie aoe 25 40.05V Standard charging current SRE ie me ene 1250 mA ic aC>TS100 Max charge current 05¢ 10C>T=0C XK aft eee 0.1c oC>TS-100 Max discharge current 3c 55C>1500 BK TH 2c OC>TS-20T Max recommended — discharge cell body Gee ee onae | Fotis a nas eT a iM 04ST Rea 0-60 Maximum short term allowable charge and discharge cell body temperature, Charging and discharging at ore . these conditions will shorten cell cycle life. ae ts Fev LAR wes eT I TRL AH (Hee FREE FEHR Ss BCE A ee IE weebit: 75°C Tnternal resistance 35 mQ(AC Impedance, 1000 Hz) al Cell dimensions Height: 65.1mmMax BAR: 65.1 mm eR Diameter: 184mm Max _ SKA: 18.4mm Weight << am ane —! 42 Cell dimensions #25 he Cell physical dimensions listed in Figure (unit; mm). RORY REM R CMG: mm). — ets mar 71 | st | eat ‘This spec manuals the enterprise standard of FST, without authorization, any pirate or Groulation ls pronDed 8 Pages/i0 rea = G IANS ARS IRA A) Edition FAR EAST FIRST NEW ENERGY CO. .LTD ‘Number: PS-RD-15 Page: 4/10 5 Technical requirements 228K 5.1 Cell storage conditions 257 FM . Temperature M/E: 3 “+A 3 months -20~45'C 3 “SALLE more than 3 months -20~35°C Relative humidit HARLHEAE: O~458RH 5.2 Cell testing conditions Hi eH ih ft Unless otherwise specified, all tests stated according to following: PRR, TAM A BORON ‘Temperature WHE: 255°C Use standard charge and standard discharge method GF HEE 6 eb Recs Jy st 5.3 _ Requirement of the testing equipment #9 HC2IER ‘Voltage meter: The precision is>0.5 KERRIER, WARRANT 0.5 ‘Temperature meter: The precision is +0.5°C GARBER, WL EN HERA IR EOS 5.4 Characteristics 8 i #8 NO. Item ‘Standard | ‘Test Method ee SE inte Wet Discharge capacity Initial capacity *100% A) 0.5C\A>100% Under the room temperature, after 0.51, (A). standard Disch B) 1C, A295% charged, rest for 15min and then discharge at 0.51, (A), ischarge Characteristics | © 2CA290% 11), 21,0) and 31,(A) to the discharge cutoff 1 (Room D) 3C, A>90% voltage 2.5V respectively. Discharge capacity of ‘Temperature) 3 : different rate accord with testing standard, saeenh | RSH AMX 100% a ce = : Rotoee staan TEST, AUIGULIRAE SH 20 LR, IE 1Smin, ES Ciaaess AHBLOSE). 11.0 21,0). 31,00 Ae coicha H2SV, RMB HLA AS MRR. D) 3C, A290% Under the room temperature, Then discharge at 11, (A)to the discharge cut-off voltage 2.5V, After 15 min to Gat Discharge capacity / Initial} charge at 21, (A) to the charge cut-off voltage 4.2V, Characteristics | apacity *100% Then discharge at 11,(A) to the discharge cut-off 2 (Room 2C1A>80% voltage 2.75V, ‘Temperature) = Rafer gin | LORRAINE x 100% #28 F, MLL 11, (A) em SV, fom sen [Smin, UL 21, (A) BRIE LALA av, da BE Usmin, BRCDL 11 (A) GHA E 2.5, ai th it. The 500th discharge capacity | Measured the initial capacity of battery. Then conduct eee |e 0.51, (/1T, (A) eyele measured the final condition of S| ames | s00 vee oe em > an su ee me | bates "80% TRANG TAR AS, AM FEAT 0.5 1, (A) M1 1, (A) AR, TR MMR eR. ‘This spec manual isthe enterprise standard of FST, without authorization, any pate or crcuaton is pronbled,Paged/10 a ® za Number: PS-RD-15 = RNS MARAIRAA —ititin vw WH van cast Finst NEW ENERGY CO. .LTD Ree ia Tested the initial condition and initial’ capacity of battery. Store for 28 days after standard charged, tested p % the final condition of battery, Then discharge at 17, (A) ee eee to the discharge cut-off voltage 2.5V, tested the residual Normal Storage | Recovery capacity >Ini capacity of battery. Then conduct 0.51, (A)/ 11, (A) very capacity Initial 1 1 aa capacity pate a cycle for 3 times to tested the recovery capacity of ae HAEREMiee Hs — | batey. ALA > Me FE R90 % URI RORUI RASA ATMA, Hen RE FE Ar AEM, FFB 28K, WAILERS, bh 11.) vit EE 2.5V, RRM eae, UL OST, (A)/ 10, (8) AR 3 2A AR Fa ‘Standard charge. Tested the initial condition of battery. Put the battery into a $5°C+2'C for 74, Then discharge io Residual capacity Initial at 11, (A) to the discharge cut-off voltage 2.5V, tested the i icity *8596 i ‘Temperature poem eapaicky Mahia residual capacity of battery. Then conduct 0.SC\\/ 10,4 Storage capacity *90% cycle for 3 times to tested the recovery capacity of uae | Bina > mth ermesss< battery MRA SBC) | sears > oyhe tt o0% MRO, snRNA MS, 7 55220 SAP REN 7d a REAL F UL 11, (A) CHS 23V, RRL RUEOAL ABER. LL 0.51, (A)/11, (A) OK 3 I A HR ar Standard charge. Then discharge at 11,(A) to 30 min ‘Tested the initial condition of battery. Store for 28 days at 4542°C temperature, measured the final condition of LongTime | Recovery capacity >Initial battery. Then conduct 0.51; (A)/ 11, (A) eycle for 3 times Sona capacity *909% to record the discharge capacity, eA BEL > MH 9036 s RSS) Sikh, 8k FUL 11,0) emt 30 4 Hi, ALMA IERAS, A aide 452°C Ft 6 28d FS, UREA TI SRS AR LL 0.51, (A)/ 11 (8) BR 9 Yee hE ae Tested the initial condition and_ initial capacity of battery. Standard charge. Put the battery into a 55°C 3 22°C for Sh, discharge at 11, (A) to the cut-off voltage a open EE | sy sien ster argea ooal Baperaion, rs High And Low meee. ) Put the battery into -20°C42°C for 24h, discharge at Temperature cea LOU 11) to 2.50V, then test the final capacity of the Discharge B) -20 © > 70% ite ‘Characteristics - of wcaice, | BOR AaL/ bona 100% MALEATE REALIS RAS, aa MARETE LE, Ae eae 4 S542'C RA PHBA Sh. DL 11, (A) ETEIE RE na Als 25V, MRERBRA TMH, 2-202 Coy iid A+ FHM 24h, VL 11, (ADHERE 2.50V, DWICRA lia Fee. This spec manuals the enterprise standard of FST, without authorization, any pale oF Orculaon & pronbied Pagess10 pa a ( = ; ape Ps — ie aURNMSRRLIIR) [Nim SED FAR EAST FIRST NEW ENERGY CO. .LTD Page: 6/10 | 5.5_ Safety Performance % 18 $2 id NO. ne ie Item Standard ‘Test Meth S 5 SB ‘tate WRI : oon Noexplosion. No fire | St#ndard charge. Charge at 11; (A) to 10V. SDE ASEM. Bik SATE EL, UM HAT RAS, UL 11, DERE "RE 10V, WER MLA MMR. : Te No. ene ze fire, | Standard charge. Discharge at 11, (4) to 90 minutes . iti FRM. TRA. Taina | ERICH, RUMANIA, DL 17, (1) HE TK 90 AEP, AURA A MEL : Standard charge. Keep the battery into a explosion-proof | tank and short-circuit the Positive and negative terminals directly (general resistance shall be less than 5mQ). Short 3 Short Circuit ‘No explosion, No fire circuit time 10 minutes. oe A RK | aime. MAAR INMoNRAS, BT TILA PCH HE TAR CREEL MLL NE SQ), $aR%0E A) | LOS, Mut ARA MENA Standard charge. Then let it fall off from a height of No explosion. No fire, 1.Sm(the lowest height) to the cement floor. 4 ped No leakage RALMTEHE, WATE MRIMIRAS, RE GRte AARKE. Bie. FRA | AEDES ACL TE GUARD FR ARVN, TARR RU ARERR Standard charge. perpendicular to the battery. The speed at 5 = Imm/s. Untill the voltage is OV or deformation is 30% or ‘Crush No explosion, No fire pe eere con 5 oR RE. Tk SARL, RUMI, BAF ei WAAL SE lmm/s WME ATH, EL EAB) ov CE RINH 30% KATES 200KN, WRIST Hat EN ERAS. | Standard charge. Keep the battery connected with a ‘thermocouple and put it into a gravity convection or circulating air oven. Temperature is raised at a rate of 5 ‘C +2 C per minute to a temperature of 130 ‘C42 ‘C and Hot Oven Noexplosion, No fire | remained for 30min at this temperature. Observe the 6 Sha FMB. Tite, variation of the battery’s appearance. TOA, WEENIE, HOLT, FSM BOE, BEV (5 C2 C) /min ERA #130 C2 CIP 30min, BRIER RMR eR. ‘This spec manuals the entorpge standard of FST, without authorization, any prate or reulaon bs prohbied.Paged/10 FAR EAST FIRST NEW ENERG ce aa Number: PS-RD-I5 # I ARRTS GERARD) Edition; 00 a co. .L7D eH | Standard charge. Keep the battery to 3.5% NaCl solution 2 hours, 7 ‘Seawater Immersion No explosion, No fire RARE. Ftwk, SRHLIRAETEMLR, WU ROE TIARAS, BRA 3 58th) NaCl #87 2h, UREA AU RES ‘Standard charge. Keep the battery to the altitude chamber ae No explosion, No fire. of 11.6Kpa 6 hours. 8 TE No leakage HUB FERS, MORENO RIAIRAS, BA MALE A AARNE TRA. IAM |, WTI 11.6Kpa, AHI, HR Gh, MIRE MUR BIBRA. Standard charge. Put the battery into a temperature controlled tank, then according to the parameter to test, A total of five times. SLHUIRAETSHLS, BAIA, aR SERIA EHR FSR, HRS. 1D APR ER At fal: ae ete a Rite) eae xc in min min 25 o 0 o 40 «0 60 12 0 30 150 o 25 o 210 wa Be aa 85 30 300 23 Heat Cycle fo explosion, No fire, 9 Properties No leakage 5 ug a0 o a A FRHIE, TRIB, AMR in ‘This spec manvalis the enterprise standard of FST, without authorzation, any pate or iculalon fe prowbied.Page7/N0 @ URSA) Se a Comments: the definitions of some nomenclatures of this specification Deed aE: Dane P BeBe Xs (1) Initial State: The initial appearance, open-circuit voltage and intemal resistance of battery. WRARA: ALLAN, FRR. CAE. (2) Final State: The final appearance, open-circuit voltage and internal resistance of battery. REORS: BUM, TR. SCTE. (3) Residual Capacity: After a specific testing program, the first discharge capacity of battery. ARE: Ine EE oe RO (4 Recovery capacity: After a specific testing program, and through the repeatedly charging and discharging to the recovery state, then the discharge capacity of battery PLEA: AHEM Ae RAE, GREE Re SFE Ch ORS ee (5) 05 C\A MI CiAs Charge at 0.5 Is (A) to limit charge voltage 4.20V, then change to charge with constant voltage ‘until the current less than or equal to 0.02 1: (A), rest for S min, then discharge at | I (A) to 2.5V cut-off. OSCAM CLA: 140.5 1,(A) Feet, Ha naiie a FEI re BM TE 4.20 BY, HEHE, BFE WUD T RET 0.02 1) FAL FEH, FEMMES. HL Sein, FELL 1 1, (a) HAMEL Eee eK 2.5V. (6) Tye 1 ANP RE HE Cy, 1 Amt ails a it (7) Initial Capacity: Standard charge method and standard discharge method at the room temperature,the discharge capacity is capacity. ‘UME: TEATS mE 9 LA AE oy ET PS RE 6 Warning and cautions in handling the lithium-ion cell Sea A FS Ss OT ED To prevent the possibility of the cell from leaking, heating, explosion, please observe the following precautions: AGILE TT He ARAL TRE, BA. MSE, EEREULF DEI Ae Don't immerse the cell in water. PRESB KT, RRM, BCE PE. Don’t use and leave the cell near heat source such as fire or heater. ALCOA RMRS, tk, MRR. ‘When charging, use a cell charger specifically for that purpose. Fee A FS TH Fe Don’t reverse the positive and negative terminals. Pra RULBL TE SAB Fs FH Don’t connect the cell to an electrical outlet directly. Pa SEL Ba Don’t discard the cell in fire or heater, SUH BEE AK SUIRE EE. Don't connect the positive and negative terminal directly with metal objects, MELAS BME STE GO, RR. Don't transport and store the cell together with metal objects such as necklaces, hairpins. SULRNE SSM, MRE. TS in RAH. Don't strike, throw or trample the cell. Sei. MAR ORER MAH AS. Don’t directly solder the cell. JEL AGRE. Don’t pierce the cell with a nail or other sharp object. SEAL AUT FREE A 28 BF HAS ‘When disposing of secondary cells, keep cells of different electrochemical systems separate from each other. SURREY APA LAL Ek MPT This Spec manual isthe enterrise standard of FST, wihout authorization, any pate or crculaion i probed PageBl10 oe aete ne ® Number: PS-RD-15 es Gj ARRAS PI GEURAS IR) Edition: 0 | WH var cast FIRST NEW ENERGY CO. -LTD Page: _[ tw Caution vty i - » Don't use or leave the cell at very high temperature conditions (for example, strong direét sunlight o extremely hot conditions). ; » SUE REF CAM FRAME) HBTS. ARUTTAS Sl Mee THA, ORTH REAP, Ae TS » Ifthe cell leaks and the electrolyte get into your eyes, don’t wipe eyes, instead, thoroughly rinse the eyes with clean running water for at least 15 minutes, and immediately seek medical attention. Otherwise, eyes injury can result URAL RACER, AARNE RE, TREE, ESRB, DEALER BREET, A SU to RL. Ifthe cell gives off an odor, generates heat, becomes discolored or deformed, or in any way appear abnormal during usage, recharging or storage, immediately remove it from the device or cell charger and stop using it. » MORI RELEOR, AA, RE, INARA. HRN. FOLATE ARR, SUS MLAS SRLS SEP STHGA. » Incase the cell terminals get dirty, clean the terminals with a dry cloth before use. » SER TERE, CORRE Ae. ' vehicle in 7 The restriction of the use of hazardous substances #2 4)/H20 BER This model of lithium-ion cell is in accordance with our company's request of “environmental substances control standard’, ANSART ALTA AA Tl] ORR Reb RE” By 8 Contact information KK #730 Ifyou have any questions regarding the cell, please contact the following address: MAREN, DA FHL A: Headquarter: Firstbattery industrial park.No.39, Yichun Economie Development Zone Jiangxi Province. (336000) hk: LHASA RAAT ARAB AY 39 SMM WE) Tel + 0795-36188 Fax : 0795-36118 HIB: 0795-3666188 fe: 0795-3666118 ‘This spec manuals the enterprise standard of FST, without authorization, any pate or crculation e prohibled ~~ Paged/10 = a en 9 Version change record (S*i12% Change item Change Content FRR #8051 A BAe PIC Al00 & WRRAT WER 2017-08-21 E a -

You might also like