First Enter Electrical Load Details Enter your Data in White Background Cells
Solar Panel Detail
Solar System Voltage (As per Battery Bank) 24 Volts DC
Losses in Wire,Connection,Battery 25 %
Daily Sunshine Hours
In Winter 3 Hrs. (For India 4 To 6 Hrs)
In Summer 5.5 Hrs.
In Monsoon 5.5 Hrs.
Average Daily Sunshine Hours 4.7 Hrs.
Total Solar Power need 2164.50 Watt.Hr/Day
Total Solar Power after Correction Factor 2705.63 Watt.Hr/Day
Solar Array Size after Calculating Sun Hour 579.78 Watt
Select Size of Solar Panel 310 watt 24
Solar Panel Connetion
Effieciency of Invertor 94 %
Enter Additional futurte Load Expansion 100 %
Size of Invertor 1257.4 Watt
RTOR ENTER LOAD DETAIL Jignesh.Parmar www.electricalno
n White Background Cells
Battery Bank Details
Battery Bank's Voltage 24 Volts DC
Reaserve Day: (No of days batteries Give Current) 1 Days
For India 4 To 6 Hrs) Loose Connection/Wire Loss Factor: 5 %
Battery Efficiency 85 %
Battery Aging: 20 %
Depth of Discharge:(DOD) 40 %
Battery Operating Temp: 22
The Battery Bank Required: 347.6 Amp.Hr
Enter Each Battery Rating 200 Amp.Hr @
Volts ###Batteries connection for Battery Bank
Battery Calculations:
Total KW.Hr/Day 2164.5 Watt.Hr/Day
Total Amp.Hr 90.19 Amp.Hr
Average Load 111.41 Amp.Hr
Storage Required 111.41 Amp.Hr
Battery Aging 133.69 Amp.Hr
Including Operating Temp 139.04 Amp.Hr
Depth of Discharge 347.59 Amp.Hr
gnesh.Parmar www.electricalnotes.wordpress.com jiguparmar@yahoo.com
0.05
0.85
0.2
0.4
12 volts ### 0
gn :
Connection
ELECTRICAL LOAD DETAIL
2164.5 Watt.Hr/Day
###