6 5 4 3 2 1

REQUIRED PANEL WIDTH

TYP WELD ALL TYP WELD ALL


SEE * BELOW SEE * LEFT 3
3 PANEL CORNERS 3 3 PANEL CORNERS 3 STANDARD SHEET WIDTH MAKE UP PIECE
SEE * BELOW
3
TACK WELD EVERY
CROSS ROD TO
BANDING OR KICKPLATE

D D

TACK WELD EVERY TACK WELD EVERY


* BANDING BAR WELD 20mm OR HALF OF DEPTH (WHICH EVER IS CROSS ROD TO CROSS ROD TO
GREATER) KICK PLATE WELD FULL DEPTH BANDING OR KICKPLATE LOAD BAR
- WELD ONE SIDE OF EVERY 5th LOAD BAR FOR A & B GRATING
- WELD ONE SIDE OF EVERY 4th LOAD BAR FOR C & D GRATING
- WELD ONE SIDE OF EVERY 3th LOAD BAR FOR E & F GRATING
- WELD ONE SIDE OF EVERY LOAD BAR FOR DRAINAGE GRATING
SIDE BANDING SIDE JOINING
SPLAY BANDING
END BANDING
TYP WELD ALL TYP WELD ALL TYP WELD ALL
CUTOUT CUTOUT CUTOUT
TYP WELD ALL 3 3 3
CORNERS CORNERS CORNERS
CUTOUT
C 3 C
CORNERS
TYP TACK TYP TACK TYP TACK
WELD WELD WELD

SEE NOTE 2

TYP WELD EVERY TYP WELD EVERY TYP WELD EVERY


TYP WELD EVERY
3 LOAD BAR 3 LOAD BAR 3 LOAD BAR
LOAD BAR 3

GRATING CUT-OUTS
TYP WELD ALL TYP WELD ALL TYP WELD ALL
CUTOUT CUTOUT CUTOUT
3 3 3
CORNERS CORNERS CORNERS
B B

TYP TACK
WELD

SEE NOTE 2
TYP TACK TYP TACK
WELD WELD

TYP WELD EVERY TYP WELD EVERY TYP WELD EVERY


3 LOAD BAR TYP WELD EVERY 3 LOAD BAR LOAD BAR 3
LOAD BAR 3

BANDING OR KICKPLATE
GRATING PENETRATIONS
A A
NOTES
1. ALL WELDS FULL DEPTH U.N.O 0 ISSUED FOR PUBLICATION AJM 12/11/21
TWIST RODS 2. ALL PENETRATIONS AND CUT-OUTS WILL BE ENLARGED TO THE NEAREST LOAD BAR WHEN REV DESCRIPTION DATE DRAWN
THEY FALL WITHIN 40MM OF THAT LOAD BAR DRAWN AJM CLIENT
3. NO WELDS TO PROTRUDE BELOW U/S OF GRATING WEBFORGE
LOAD BARS DRAWN DATE 22/10/21
4. ALL BANDING BARS TO BE 5mm THICK, ALL KICK PLATE TO BE 6mm THICK PRODUCT
JK
5. BANDING WILL BE IN PLAIN MATERIAL UNLESS SPECIFIED OTHERWISE PROJECTION APPROVED FLOORING
6. 3mm WELD IS THE MINIMUM SIZE REQUIRED APPROVED DATE 12/11/21 STEEL GRATING - WELDING
DRAWING DISCLAIMER: DO NOT SCALE
WEBFORGE PROVIDES THE INFORMATION CONTAINED IN THIS DRAWING AS A GUIDE FOR YOUR INFORMATION ONLY. WEBFORGE HAS 7. EDGE BARS BETWEEN SIDE CUT AND JOINED SERRATED PANELS MUST BE SERRATED STANDARD
TAKEN REASONABLE CARE TO ENSURE THE ACCURACY OF THE INFORMATION AT THE TIME OF PRODUCTION. WEBFORGE EXPRESSLY ALL
DISCLAIMS ALL LIABILITY WHATSOEVER FOR (INCLUDING ANY DIRECT OR INDIRECT LOSS OR DAMAGE, COSTS OR EXPENSES HOWSOEVER DRAWING NUMBER SHEET REV
INCURRED BY ANY PERSON) RELIANCE ON THE WHOLE OR ANY PART OF THE INFORMATION CONTAINED IN OR OMITTED FROM THIS
DIMENSIONS
DRAWING. WEBFORGE RESERVES THE RIGHT TO MAKE TECHNICAL CHANGES WITHOUT NOTICE. IN mm U.N.O. FLGR-EX-001 1 OF 1 0
6 5 4 3 2 1
C:\Vault\Projects\Webforge\STANDARD DRAWINGS\Flooring\Drawings\FLGR-EX-001.dwg

You might also like