Electrical Installation Takeoff sheet

T D S

37

13

15

1
6

15

34

18

5
5

15

25
Electrical Installation Takeoff sheet
Description
1) ELECTRICAL INSTALLATION
1) Distribution board
1.1) MDB (Main Distribution Board) of 15A/ 1-Phase (No.)

1.2) SDB (Sub Distribution Board) (No.)

2) Light Points.
2.1) Light point fed through PVC insulated conductors of 2 X 2.5mm 2, inside PVC
conduit of 16mm diameter, including junction boxes with cover, insulating screw
cap connectors, all for flush mounting.LIGHTING (No.)

2.2) Extra over light points:(Type Legrand Mosaic or Equivalent complete with boxes,
screw type plates and accessories) SWITCHES

2.2.1 Single switch (No.)

2.2.2 Double switch (No.)

2.2.3 Two way switch (No.)

3) Light fittings and lamps


(Specified type or equivalent)

3.1) wall mounted luminaire RZB 56225+056150 with energy saving lamp

3.2) pendant celling luminaire MASSIVE 36102/17/10 E14/max 40w

3.3) Celling mounted luminaire RZB 621014.984.79 TC-L 24W

3.4) pendant celling luminaire MASSIVE 36101/17/10 5XE14/max 40w


3.5) wall mounted luminaire RZB 56125+056150 with energy saving lamp

3.6) Celling mounted luminaire MASSIVE 12562/01/43 e14 max 40w

3.7) Fluorescent fitting type PHILIPS TMS 012/236 with 2XTLD 36W

3.8) Fluorescent fitting type PHILIPS TMS 012/236 with 1XTLD 36W

3.9) Recessed stairway luminaire RZB 311166.952.Q with TC-D 26W

4) Socket outlets.
4.1) Socket out lets of flush mounting fed through PVC conductors of 3x2.5mm 2,
inside PVC conduit of 16mm diameter, including junction boxes with cover,
insulating screw cap connectors, all for flush mounting.
(No.)
4.2) Extra Over Socket outlet Points (Type Legrand Mosaic or Equivalent complete
with boxes, screw type plates and accessories)

4.2.1) Single Socket Outlet 16A,250V (No.)

4.2.2) Single Socket Outlet -WP 16A,250V (No.)

4.2.3) Stove Outlet 20A,250V (No.)

4.2.4) Twin Socket Outlet 16A,250V (No.)

4.2.5) Water Heater Outlet 16A,250V (No.)

5)TEL/Data System
5.1) Telecom points fed through 1x(twisted pair category 5E UTP cable ) inside PVC
conduit of 20mm diameter. (No.)

5.2) RJ-11 Data outlet CAT-5E, type Legrand (No.)

5.3) Tel/Data terminal boxes. (No.)

6) TV System
6.1) TV point fed through 75Ohms Co-axial cable suitable for VHF-UHF signal
distribution inside PVC conduit of 20mm diameter including spilitters ,connectors
and terminal type. (No.)
6.2) TV socket outlet for flush mounting (No.)

6.3) TV terminal boxes. (No.)

7) Bell Call System


7.1) Bell call point fed through PVC insulated conductors of 2x1.0mm 2 inside PVC
conduit of 13mm diameter, including junction boxes with covers, insulating screw
cap connector all for flush mounting. (No.)

7.2) Bell push button (No.)

7.3) Bell call indicator with 8 number

8) Feeder Power Cable


8.1) Feeder PVC sheathed insulated power cable of 5x10 mm 2 inside PVC conduit of
50mm diameter from KWHM to MDB. (ML)

8.2) Feeder PVC sheathed insulated power cable of 5X4mm 2 inside PVC conduit of
21mm diameter from MDB to SDB-GF. (ML)

8.2) Feeder PVC sheathed insulated power cable of 5X4mm 2 inside PVC conduit of
21mm diameter from MDB to SDB-1F. (ML)

You might also like