Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617

Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
Bill of Quantities- Part 1
1 Building
5.04.03.01.2
Works
Brick work of Kiln 1st class bricks/automatic machine made first class bricks in cement mortar (1:6) in superstructure with Portland Composite cum 3.824 8192.26 31327
cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) with uniform width and depth joints, true to vertical and horizontal lines,
in/c raking out joints, filling interstices tightly with mortar, cleaning and soaking bricks at least for 24 hours before use, washing of sand,
necessary scaffolding, curing for requisite period, etc. all complete as per direction of the E-I-C. Kiln bricks Add for each additional floor up to
5th floor
2 Additional
5.04.10.01.2_
Item
125mm brick work with Kiln 1st class bricks/automatic machine made first class bricks in cement mortar (1:4) with Portland Composite cement sqm 104.1 1215.97 126551
(CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) and making bond with connected walls with uniform width and depth joints, true to
vertical and horizontal lines in/c necessary scaffolding, raking out joints, cleaning and soaking the bricks at least for 24 hours before use,
washing of sand, curing for requisite period, etc. all complete as per direction of the E-I-C. Kiln bricks Add for each additional floor up to 5th
floor
3 Building
5.05.01.03.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 7.847 15192.35 119214
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In pedestal, column, capital lift wall and wall : Add for each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
4 Building
5.05.01.04.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 1.954 13156.39 25708
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Tie Beam and Lintel : Add for each additional floor up to 5th Floor

5 Building
5.05.01.05.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 8.228 13834.44 113830
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Tee Beam, Ell Beam, Rectangular Beam etc. (exposed breadth and width of ribs to be measured only). Add for
each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
6 Building
5.05.01.06.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 22.16 13640.95 302324
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In roof slab of all types, cantilever slab and drop panels (excluding floor slab of ground floor at plinth level). Add
for each additional floor up to 5th Floor

7 Building
5.05.01.07.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 0.585 18070.37 10571
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In sunshade, cornice, railing, drop wall, louver and fins (Average 62mm to 87mm thick) Add for each additional
floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
8 Building
5.05.01.08.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 3.404 13934.64 47434
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Stair case slab and step Add for each additional floor up to 5th Floor

9 Building
5.06.01.01
Works
Supplying and fabrication of Ribbed or deformed bar reinforcement for all types of RCC work including straightening, removing ruts, cleaning, kg 7097 89.18 632929
cutting, hooking, bending, lapping and/or welding wherever required as directed, placing in position, tieing with 22 BWG black annealed binding
wire (PVC coated in case of FBEC rebar) double fold, cost of binding wire and anchoring to the adjoining members wherever necessary,
supplying and placing with proper cover blocks (1:1), supports, chairs, spacers, splices or laps etc. including cost of all materials, cost of
labour, cost of equipment & machinery, loading and unloading, transportation, all other incidental charges and work at all leads and lifts etc. to
complete the work as per design, drawing, specifications and direction of the E-I-C. Measurement relating to nominal mass, dimensions and
tolerances of various types of steel shall conform to relevant BDS/ ASTM codes. Reinforcement shall be measured only in lengths of bar as
actually placed in position on standard weight i.e. 7850 kg/m3 (BNBC Table 6.2.1) basis. No separate payment shall be allowed for Chairs of
any shape & profile, spacer bar of any shape & profile, lap/ splice unless otherwise shown in the drawing, wastages, binding wire, concrete
cover blocks etc. as the cost of these is included in the unit rate. Note: Tests for reinforcing bars shall be conducted at LGED/ BUET/ CUET/
KUET/ RUET. Grade 300 (RB 300): Ribbed or Deformed bar produced and marked as per BDS ISO 6935-2:2006 with minimum yield strength,
fy (ReH) = 300 MPa, but the tested yield strength shall not exceed fy by more than the 125 MPa and the ratio of tested ultimate strength, fu
(Re) to tested yield strength (fy) shall be at least 1.25 and minimum elongation after fracture (A5.65) & minimum total elongation at maximum
force (Agt) is 16% and 2.5% respectively.

10 Building
5.12.01
Works
Minimum 12mm thick cement plaster (1:4) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to sqm 11.33 304.950 3454
dado, plinth wall up to 150mm below ground level, water tank or any where directed with neat cement finishing in/c washing of sand, racking
out joint and picking up cement morter i/c finishing the edges and corners and curing for the requisite period etc. all complete as per direction of
the E-I-C.
11 Building
5.12.02.02
Works
Minimum 12mm thick cement plaster (1:6) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to wall sqm 312.5 269.555 84223
both inner and outer surface, finishing the corner and edges in/c washing of sand cleaning the surface, scaffolding and curing for the requisite
period etc. all complete as per direction of the E-I-C. Add for each additional floor for 5th floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
12 Building
5.12.03.02
Works
Minimum 6mm thick cement plaster (1:4) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to sqm 387.2 251.499 97373
ceiling RCC columns, beams, surface of stair case, sunshades, cornices, railings, drop wall, louvers, fins and finishing the corners and edges
in/c washing of sand cleaning the surface, scaffolding and curing for the requisite period etc. all complete as per direction of the E-I-C. Add for
each additional floor upto 5th floor
13 Building
5.12.10
Works
Providing drip course/nosing/throating at the edge of sunshade or cornice with cement mortar (1:2) with Portland Composite cement (CEM m 49.33 150.530 7425
II/AM, 42.5N) and best quality sand (minimum FM1.2) in/c. scaffolding, curing at least for 7 days etc. all complete for all floors as per direction
of the E-I-C .
14 Building
5.12.22
Works
Plaster rule pointing works 250mmx75mm size as brick shape by 10mmx10mm grove on outside wall over minimum 12mm thick cement sqm 81.1 324.180 26292
plaster (1:6) with Portland Composite cement (CEM II/AM, 42.5N), best quality sand (minimum FM1.2), finishing the corners and edges
including washing of sand, cleaning the surface, scaffolding and curing for requisite period etc. all complete as per drawing and direction of the
E-I-C.
15 Building
5.13.01
Works
25mm thick artificial patent stone floor (1:2:4) with Portland Composite cement (CEM II/AM, 42.5N), best quality coarse sand (minimum FM1.8) sqm 188.8 397.340 75031
and 10mm down well graded picked brick chips (LAA value not exceeding 38) in/c breaking graded picked chips, screening, mixing, laying the
concrete in alternate panels, compacting and finishing the top with neat cement, curing, etc. all complete as per direction of the E-I-C.

16 Building
5.16.05.01
Works
Painting with plastic emulsion paint of best quality and approved colour in a seal container from authorized manufacturer. Applying each coat sqm 513.2 261.310 134103
and successive coat is to be applied as per manufacturer special procedure, to wall and ceiling in two coats over a coat of priming coat of
water sealer and ready mixed putty of approved brand. It applied on sand papered and cleaned surface and after drying applied sealer coat, 2
coats of ready mixed wall putty of approved brand, each coat dried and smoothened by sand papering. Applying plastic emulsion paint one
vertical and one horizontal coat for each coat and successive coat is to be applied after drying up of previous coat by brush/roller/spray in/c
cleaning the plinth, floors, doors, windows, portions and ventilators by washing, rubbing, as necessary and sand papering the surface and
necessary scaffolding, etc. curing for the requisite period etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

17 Building
5.16.09.01
Works
On exterior surface applying as per manufacturer instruction specific coat of weather coat of approved quality and colour delivered from sqm 267.5 277.820 74325
authorized local agent of the manufacturer in a sealed container. Applying one vertical and one horizontal coat for each coat and successive
coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand papering the
surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C. 3 coat

18 Additional
N.S.I.01
Item
Supplying 4'' pad lock and key in dulicate (China/Globe) as per direction of the E/C each 6 550.10 3301
19 Additional
N.S.I.08
Item
Painting to dado, skirting, out side plinth wall, out side plinth walls painting wall will be from 6'' below GL to plinth level with two coats with sqm 11.33 245.69 2783
synthetic enamel black paint of best quality and approve colour over a coat of priming in/c clearing finishing and polishing etc. all complete as
per direction of the Engineer-in-charge.
20 Building
5.19.04
Works
Supplying, fitting and fixing stair railing or any where directed made of 50mm dia GI pipe of minimum wall thickness 2.90mm hand rail on top sqm 7.796 4859.720 37886
and 20mm dia GI pipe series of minimum wall thickness 2.1mm-2.2mm provided 50mm c/c parallel to hand rail as per drawing (top and bottom
gap 125mm) fixed with vertical 40mm dia GI pipe post minimum wall thickness 2.65mm @ 900mm c/c which fixed in 6mm thick MS plate angle
cleat (top 75mmx75mm and vertical 75mmx100mm) welded to vertical post fixed to stair concrete with 12mm dia MS royal bolt (4 nos) i/c cost
of fabricating, cutting, bending, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c. cutting grooves in
the R.C.C. or brick work, mending good the damages with C.C. (1:2.4) for all floors etc. all complete as per design and direction of the E-I-C.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
21 Building
5.12.05
Works
Providing black board (3.66mx1.22m/2.44mmx1.22mm or directed size) made of 12mm thick cement sand plaster of proportion (1:3) with sqm 13.4 374.27 5013
Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) on walls finished smooth with cement grouting mixed
with black oxide board paint over the cement finishing etc. all complete as per direction of the E-I-C.

22 Building
5.07.03.1
Works
Supplying, fitting and fixing door frame with MS angle (50mmx50mmx6mm), fixing, 250mm long 6 nos. of iron clamps of same size (one end m 31.68 1234.03 39094
bifurcated) with vertical members of the frame, fixing the frame in wall with cement concrete (1:2:4) in Portland Composite cement CEM II/AM,
42.5N), best quality sand (minimum FM1.8) and 20mm down well graded 1st class brick chips, mending good damages, fixing 3 nos. of 100mm
size iron hinges with the vertical members of the frame for single leaf shutter, painting all iron faces in 2 coats over a coat of priming with
enamel paint of approved colour and quality, in/c cutting, sizing, welding for all floors, etc. all complete as per plan and direction of the E-I-C
MS angle 50mmx50mmx6mm size

23 Building
5.08.03.05
Works
Supplying, fitting and fixing 38mm thick well matured natural seasoned wooden panel door shutters (minimum 250mm wide plank), top, rail and sqm 12.97 8005.55 103848
styles of sections (100mmx38mm), lock rail (125mmx38mm) and bottom rail (225mmx38mm) paneling 38mm thick both sides raised, provided
with best quality 6 nos. 100mm iron hinges, 2 nos. best quality 12mm dia 300mm and 225mm long iron tower and socket bolts 2 nos. heavy
type nickel plated handle, hinge cleats, buffer blocks and finished with sand papering for all floors etc. all complete as per direction of the E-I-C.
(Single/Double leaf. All sizes of wood are finished). Mehagoni wood

24 Building
5.08.12.02
Works
Supplying, fitting and fixing combined steel window shutter, frames and grill welded together as per drawing & design having requisite Nos. of sqm 28.82 4098.15 118125
vertical and horizontal standard MS (19mmx19mmx3mm) ?Z' section for shutter and MS flat bar all around (25mmx4.5mm) and (19mmx3mm),
10mm square bar as grill welded horizontally @ 100mm c/c, only catch locking handle position gap should 125mm, at inner face of window
frame with F.I. clamp 75mmx3mm duly embedded with Cement Concrete (1:2:4:) and mending good the damages in/c all cost of charges for
fabrication and manufacture by welding, riveting, etc. supplying all essential fittings like stopper, handle, 3 nos catch hook 300mm long
adjustable iron cleat, 50mm long pin hinge in/c supplying, fitting, fixing 18 BWG M.S. sheet in position welded to steel shutter with Tee stiffener
(2 nos.) made with 25mm and 19mm flat bars fitted to shutter frame in Two equal part and upper part should be provided with 5mm clear glass,
vertically in each shutter panel and putty and painting the window with two coats of synthetic enamel paint over a coat of anticorrosive priming, ,
etc for all floors. all complete as per direction of the E-I-C

25 Building
5.16.10.01
Works
Painting to door and window frames, shutters and any type of MS rod, FI bar, MS box, MS angle grill, gate etc. in two coats with synthetic sqm 32.43 245.69 7968
enamel paint of best quality and approved colour over a coat of priming. Applying one vertical and one horizontal coat for each coat and
successive coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand
papering the surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

26 Building
5.10.14
Works
Supplying, fitting and fixing verandah drop or ventilation Grill or anywhere as directed made of 10mmX10mm MS square bar series welded to sqm 10.8 4246.36 45839
outer frame made of MS flat bar of size 25mmx3mm having anchoring Clamps of 25mmx25mmx3mm MS Angle @750mm c/c to be embaded
in RCC or Brick work i/c cost of fabricating, cutting, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c.
cutting grooves in the R.C.C. or brick work, mending good the damages with Cement Concrete (1:2.4) for all floors etc. all complete as per
design and direction of the E-I-C.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
27 Building
5.19.08
Works
Supplying, fitting and fixing verandah railing or any where as directed made of 20mm dia GI pipe of minimum wall thickness 2.1mm-2.2mm @ sqm 25.66 4720.09 121094
100mm c/c and 50mm dia GI pipe of minimum wall thickness 2.65mm top in horizontal ways (top and bottom gap 125mm) as per design and
drawing fixed with vertical 800mmx100mmx6mm H type MS plate post @ 900mm c/c which fixed in middle portion 20mm dia GI pipe post in
between 50mmx25mmx5mm FI bar) with provision of 20mm GI pipe of minimum wall thickness 2.1mm-2.2mm passing hole in/c making hole in
MS plate and FI bars in required diameter. All post fixing in floor by 100mmx150mm x 6mm MS base plate with 12mm dia MS royal bolt i/c cost
of fabricating, cutting, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c. cutting grooves in the R.C.C.
or brick work, mending good the damages with C.C. (1:2.4) for all floors etc. all complete as per design and direction of the E-I-C.

28 Building
5.08.14.02
Works
Supplying, fitting and fixing steel glazed sky light frame (Stair Back fixed Window) at stairs as per design having ?T' section made with flat bar sqm 2.544 3191.600 8119
25mmx3mm as base and 19mmx3mm flat bar as perpendicular at mid of base flat bar welded 200mm c/c grid and Outer frame having
25mmx25mmx3mm MS angle in/c all cost of charges for fabrication and manufacture by welding, riveting, etc. supplying all essential fittings
like 150mm long clamps for fitting frame in/c supplying, fitting, fixing 5mm thick glass panes at grid opening by putty and painting the sky light
with two coats of synthetic enamel paint over a coat of anticorrosive priming, making necessary holes in wall and RCC work as necessary,
filling with CC (1:2:4:) and mending good the damages for all floors, etc. all complete as per direction of the E-I-C and as per drawing and
design.
29 Building
5.04.14.03.2
Works
Fancy screen (Ornamental Screen) work with different size machine made design blocks with uniform colour, carefully laid in coloured cement sqm 5.442 3017.55 16421
mortar (1:3) in all floors in wall with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) with uniform
mortar joints, true to vertical and horizontal line including racking out joints, cleaning and soaking the blocks for minimum 24 hours before use
including washing and screening of sand, scaffolding, curing for requisite period etc. complete in all respect including supply of all necessary
materials including cost of water, electricity and other charges etc. all complete as per direction of the E-I-C. Block Size :
150mmx150mmx100mm (MCW-Design No.20/21/27 or equivalent volume & design) Add for each additional floor up to 5th Floor

30 Sanitary,
7.08.05.04
Water
Supplying
Supply100mm
& Firedia
Fighting
(inside)
Works
best quality PVC rain water down pipes, fitted and fixed in position with sockets head and shoes, bends, clamps m 12.2 387.760 4731
and nails etc. all complete in all floors (Aziz / Lira / National / Polymer or equivalent water grade PVC Pipe) as per direction of the E-I-C.

31 Building
5.04.03.01.2
Works
Brick work of Kiln 1st class bricks/automatic machine made first class bricks in cement mortar (1:6) in superstructure with Portland Composite cum 3.118 8192.26 25543
cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) with uniform width and depth joints, true to vertical and horizontal lines,
in/c raking out joints, filling interstices tightly with mortar, cleaning and soaking bricks at least for 24 hours before use, washing of sand,
necessary scaffolding, curing for requisite period, etc. all complete as per direction of the E-I-C. Kiln bricks Add for each additional floor up to
5th floor
32 Additional
5.04.10.01.2_
Item
125mm brick work with Kiln 1st class bricks/automatic machine made first class bricks in cement mortar (1:4) with Portland Composite cement sqm 75.12 1215.97 91339
(CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) and making bond with connected walls with uniform width and depth joints, true to
vertical and horizontal lines in/c necessary scaffolding, raking out joints, cleaning and soaking the bricks at least for 24 hours before use,
washing of sand, curing for requisite period, etc. all complete as per direction of the E-I-C. Kiln bricks Add for each additional floor up to 5th
floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
33 Building
5.05.01.03.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 4.956 15192.35 75293
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In pedestal, column, capital lift wall and wall : Add for each additional floor up to 5th Floor

34 Building
5.05.01.04.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 0.846 13156.39 11130
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Tie Beam and Lintel : Add for each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
35 Building
5.05.01.05.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 4.109 13834.44 56846
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Tee Beam, Ell Beam, Rectangular Beam etc. (exposed breadth and width of ribs to be measured only). Add for
each additional floor up to 5th Floor

36 Building
5.05.01.06.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 10.27 13640.95 140052
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In roof slab of all types, cantilever slab and drop panels (excluding floor slab of ground floor at plinth level). Add
for each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
37 Building
5.05.01.07.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 0.195 18070.37 3524
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In sunshade, cornice, railing, drop wall, louver and fins (Average 62mm to 87mm thick) Add for each additional
floor up to 5th Floor

38 Building
5.05.01.08.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 3.404 13934.64 47434
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Stair case slab and step Add for each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
39 Building
5.06.01.01
Works
Supplying and fabrication of Ribbed or deformed bar reinforcement for all types of RCC work including straightening, removing ruts, cleaning, kg 3873 89.18 345379
cutting, hooking, bending, lapping and/or welding wherever required as directed, placing in position, tieing with 22 BWG black annealed binding
wire (PVC coated in case of FBEC rebar) double fold, cost of binding wire and anchoring to the adjoining members wherever necessary,
supplying and placing with proper cover blocks (1:1), supports, chairs, spacers, splices or laps etc. including cost of all materials, cost of
labour, cost of equipment & machinery, loading and unloading, transportation, all other incidental charges and work at all leads and lifts etc. to
complete the work as per design, drawing, specifications and direction of the E-I-C. Measurement relating to nominal mass, dimensions and
tolerances of various types of steel shall conform to relevant BDS/ ASTM codes. Reinforcement shall be measured only in lengths of bar as
actually placed in position on standard weight i.e. 7850 kg/m3 (BNBC Table 6.2.1) basis. No separate payment shall be allowed for Chairs of
any shape & profile, spacer bar of any shape & profile, lap/ splice unless otherwise shown in the drawing, wastages, binding wire, concrete
cover blocks etc. as the cost of these is included in the unit rate. Note: Tests for reinforcing bars shall be conducted at LGED/ BUET/ CUET/
KUET/ RUET. Grade 300 (RB 300): Ribbed or Deformed bar produced and marked as per BDS ISO 6935-2:2006 with minimum yield strength,
fy (ReH) = 300 MPa, but the tested yield strength shall not exceed fy by more than the 125 MPa and the ratio of tested ultimate strength, fu
(Re) to tested yield strength (fy) shall be at least 1.25 and minimum elongation after fracture (A5.65) & minimum total elongation at maximum
force (Agt) is 16% and 2.5% respectively.

40 Building
5.12.01
Works
Minimum 12mm thick cement plaster (1:4) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to sqm 7.077 304.950 2158
dado, plinth wall up to 150mm below ground level, water tank or any where directed with neat cement finishing in/c washing of sand, racking
out joint and picking up cement morter i/c finishing the edges and corners and curing for the requisite period etc. all complete as per direction of
the E-I-C.
41 Building
5.12.02.02
Works
Minimum 12mm thick cement plaster (1:6) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to wall sqm 136 269.555 36653
both inner and outer surface, finishing the corner and edges in/c washing of sand cleaning the surface, scaffolding and curing for the requisite
period etc. all complete as per direction of the E-I-C. Add for each additional floor for 5th floor

42 Building
5.12.03.02
Works
Minimum 6mm thick cement plaster (1:4) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to sqm 208.1 251.499 52329
ceiling RCC columns, beams, surface of stair case, sunshades, cornices, railings, drop wall, louvers, fins and finishing the corners and edges
in/c washing of sand cleaning the surface, scaffolding and curing for the requisite period etc. all complete as per direction of the E-I-C. Add for
each additional floor upto 5th floor
43 Building
5.12.10
Works
Providing drip course/nosing/throating at the edge of sunshade or cornice with cement mortar (1:2) with Portland Composite cement (CEM m 35.16 150.530 5293
II/AM, 42.5N) and best quality sand (minimum FM1.2) in/c. scaffolding, curing at least for 7 days etc. all complete for all floors as per direction
of the E-I-C .
44 Building
5.12.22
Works
Plaster rule pointing works 250mmx75mm size as brick shape by 10mmx10mm grove on outside wall over minimum 12mm thick cement sqm 69.03 324.180 22378
plaster (1:6) with Portland Composite cement (CEM II/AM, 42.5N), best quality sand (minimum FM1.2), finishing the corners and edges
including washing of sand, cleaning the surface, scaffolding and curing for requisite period etc. all complete as per drawing and direction of the
E-I-C.
45 Building
5.13.01
Works
25mm thick artificial patent stone floor (1:2:4) with Portland Composite cement (CEM II/AM, 42.5N), best quality coarse sand (minimum FM1.8) sqm 53.91 397.340 21420
and 10mm down well graded picked brick chips (LAA value not exceeding 38) in/c breaking graded picked chips, screening, mixing, laying the
concrete in alternate panels, compacting and finishing the top with neat cement, curing, etc. all complete as per direction of the E-I-C.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
46 Building
5.16.05.01
Works
Painting with plastic emulsion paint of best quality and approved colour in a seal container from authorized manufacturer. Applying each coat sqm 250.3 261.310 65414
and successive coat is to be applied as per manufacturer special procedure, to wall and ceiling in two coats over a coat of priming coat of
water sealer and ready mixed putty of approved brand. It applied on sand papered and cleaned surface and after drying applied sealer coat, 2
coats of ready mixed wall putty of approved brand, each coat dried and smoothened by sand papering. Applying plastic emulsion paint one
vertical and one horizontal coat for each coat and successive coat is to be applied after drying up of previous coat by brush/roller/spray in/c
cleaning the plinth, floors, doors, windows, portions and ventilators by washing, rubbing, as necessary and sand papering the surface and
necessary scaffolding, etc. curing for the requisite period etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

47 Building
5.16.09.01
Works
On exterior surface applying as per manufacturer instruction specific coat of weather coat of approved quality and colour delivered from sqm 162.7 277.820 45205
authorized local agent of the manufacturer in a sealed container. Applying one vertical and one horizontal coat for each coat and successive
coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand papering the
surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C. 3 coat

48 Additional
N.S.I.01
Item
Supplying 4'' pad lock and key in dulicate (China/Globe) as per direction of the E/C each 2 550.10 1100
49 Additional
N.S.I.08
Item
Painting to dado, skirting, out side plinth wall, out side plinth walls painting wall will be from 6'' below GL to plinth level with two coats with sqm 7.077 245.69 1739
synthetic enamel black paint of best quality and approve colour over a coat of priming in/c clearing finishing and polishing etc. all complete as
per direction of the Engineer-in-charge.
50 Building
5.19.04
Works
Supplying, fitting and fixing stair railing or any where directed made of 50mm dia GI pipe of minimum wall thickness 2.90mm hand rail on top sqm 7.796 4859.720 37886
and 20mm dia GI pipe series of minimum wall thickness 2.1mm-2.2mm provided 50mm c/c parallel to hand rail as per drawing (top and bottom
gap 125mm) fixed with vertical 40mm dia GI pipe post minimum wall thickness 2.65mm @ 900mm c/c which fixed in 6mm thick MS plate angle
cleat (top 75mmx75mm and vertical 75mmx100mm) welded to vertical post fixed to stair concrete with 12mm dia MS royal bolt (4 nos) i/c cost
of fabricating, cutting, bending, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c. cutting grooves in
the R.C.C. or brick work, mending good the damages with C.C. (1:2.4) for all floors etc. all complete as per design and direction of the E-I-C.

51 Building
5.12.05
Works
Providing black board (3.66mx1.22m/2.44mmx1.22mm or directed size) made of 12mm thick cement sand plaster of proportion (1:3) with sqm 4.465 374.27 1671
Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) on walls finished smooth with cement grouting mixed
with black oxide board paint over the cement finishing etc. all complete as per direction of the E-I-C.

52 Building
5.07.03.1
Works
Supplying, fitting and fixing door frame with MS angle (50mmx50mmx6mm), fixing, 250mm long 6 nos. of iron clamps of same size (one end m 10.56 1234.03 13031
bifurcated) with vertical members of the frame, fixing the frame in wall with cement concrete (1:2:4) in Portland Composite cement CEM II/AM,
42.5N), best quality sand (minimum FM1.8) and 20mm down well graded 1st class brick chips, mending good damages, fixing 3 nos. of 100mm
size iron hinges with the vertical members of the frame for single leaf shutter, painting all iron faces in 2 coats over a coat of priming with
enamel paint of approved colour and quality, in/c cutting, sizing, welding for all floors, etc. all complete as per plan and direction of the E-I-C
MS angle 50mmx50mmx6mm size

53 Building
5.08.03.05
Works
Supplying, fitting and fixing 38mm thick well matured natural seasoned wooden panel door shutters (minimum 250mm wide plank), top, rail and sqm 4.324 8005.55 34616
styles of sections (100mmx38mm), lock rail (125mmx38mm) and bottom rail (225mmx38mm) paneling 38mm thick both sides raised, provided
with best quality 6 nos. 100mm iron hinges, 2 nos. best quality 12mm dia 300mm and 225mm long iron tower and socket bolts 2 nos. heavy
type nickel plated handle, hinge cleats, buffer blocks and finished with sand papering for all floors etc. all complete as per direction of the E-I-C.
(Single/Double leaf. All sizes of wood are finished). Mehagoni wood
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
54 Building
5.08.12.02
Works
Supplying, fitting and fixing combined steel window shutter, frames and grill welded together as per drawing & design having requisite Nos. of sqm 12.12 4098.15 49653
vertical and horizontal standard MS (19mmx19mmx3mm) ?Z' section for shutter and MS flat bar all around (25mmx4.5mm) and (19mmx3mm),
10mm square bar as grill welded horizontally @ 100mm c/c, only catch locking handle position gap should 125mm, at inner face of window
frame with F.I. clamp 75mmx3mm duly embedded with Cement Concrete (1:2:4:) and mending good the damages in/c all cost of charges for
fabrication and manufacture by welding, riveting, etc. supplying all essential fittings like stopper, handle, 3 nos catch hook 300mm long
adjustable iron cleat, 50mm long pin hinge in/c supplying, fitting, fixing 18 BWG M.S. sheet in position welded to steel shutter with Tee stiffener
(2 nos.) made with 25mm and 19mm flat bars fitted to shutter frame in Two equal part and upper part should be provided with 5mm clear glass,
vertically in each shutter panel and putty and painting the window with two coats of synthetic enamel paint over a coat of anticorrosive priming, ,
etc for all floors. all complete as per direction of the E-I-C

55 Building
5.16.10.01
Works
Painting to door and window frames, shutters and any type of MS rod, FI bar, MS box, MS angle grill, gate etc. in two coats with synthetic sqm 10.81 245.69 2656
enamel paint of best quality and approved colour over a coat of priming. Applying one vertical and one horizontal coat for each coat and
successive coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand
papering the surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

56 Building
5.10.14
Works
Supplying, fitting and fixing verandah drop or ventilation Grill or anywhere as directed made of 10mmX10mm MS square bar series welded to sqm 4.735 4246.36 20107
outer frame made of MS flat bar of size 25mmx3mm having anchoring Clamps of 25mmx25mmx3mm MS Angle @750mm c/c to be embaded
in RCC or Brick work i/c cost of fabricating, cutting, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c.
cutting grooves in the R.C.C. or brick work, mending good the damages with Cement Concrete (1:2.4) for all floors etc. all complete as per
design and direction of the E-I-C.
57 Building
5.19.08
Works
Supplying, fitting and fixing verandah railing or any where as directed made of 20mm dia GI pipe of minimum wall thickness 2.1mm-2.2mm @ sqm 14.01 4720.09 66114
100mm c/c and 50mm dia GI pipe of minimum wall thickness 2.65mm top in horizontal ways (top and bottom gap 125mm) as per design and
drawing fixed with vertical 800mmx100mmx6mm H type MS plate post @ 900mm c/c which fixed in middle portion 20mm dia GI pipe post in
between 50mmx25mmx5mm FI bar) with provision of 20mm GI pipe of minimum wall thickness 2.1mm-2.2mm passing hole in/c making hole in
MS plate and FI bars in required diameter. All post fixing in floor by 100mmx150mm x 6mm MS base plate with 12mm dia MS royal bolt i/c cost
of fabricating, cutting, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c. cutting grooves in the R.C.C.
or brick work, mending good the damages with C.C. (1:2.4) for all floors etc. all complete as per design and direction of the E-I-C.

58 Building
5.08.14.02
Works
Supplying, fitting and fixing steel glazed sky light frame (Stair Back fixed Window) at stairs as per design having ?T' section made with flat bar sqm 2.544 3191.600 8119
25mmx3mm as base and 19mmx3mm flat bar as perpendicular at mid of base flat bar welded 200mm c/c grid and Outer frame having
25mmx25mmx3mm MS angle in/c all cost of charges for fabrication and manufacture by welding, riveting, etc. supplying all essential fittings
like 150mm long clamps for fitting frame in/c supplying, fitting, fixing 5mm thick glass panes at grid opening by putty and painting the sky light
with two coats of synthetic enamel paint over a coat of anticorrosive priming, making necessary holes in wall and RCC work as necessary,
filling with CC (1:2:4:) and mending good the damages for all floors, etc. all complete as per direction of the E-I-C and as per drawing and
design.
59 Building
5.12.17
Works
44mm thick on an average roof top cement concrete screed in proportion (1:1.5:3) with 10mm down graded crushed 1st class brick sqm 103.4 690.530 71373
chips/picked chips, (LAA value not exceeding 38), cement and sand (minimum FM 1.8) including Cement grouting, mixing concrete, laying with
neat cement finishing on the following day of roof slab casting, cost of all materials, labour and transportation to the site, finishing the edges
and corners, curing for the requisite period etc. all complete as per drawing, specification and direction of the E-I-C
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
60 Building
5.04.14.03.2
Works
Fancy screen (Ornamental Screen) work with different size machine made design blocks with uniform colour, carefully laid in coloured cement sqm 1.814 3017.55 5474
mortar (1:3) in all floors in wall with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) with uniform
mortar joints, true to vertical and horizontal line including racking out joints, cleaning and soaking the blocks for minimum 24 hours before use
including washing and screening of sand, scaffolding, curing for requisite period etc. complete in all respect including supply of all necessary
materials including cost of water, electricity and other charges etc. all complete as per direction of the E-I-C. Block Size :
150mmx150mmx100mm (MCW-Design No.20/21/27 or equivalent volume & design) Add for each additional floor up to 5th Floor

61 Sanitary,
7.08.05.04
Water
Supplying
Supply100mm
& Firedia
Fighting
(inside)
Works
best quality PVC rain water down pipes, fitted and fixed in position with sockets head and shoes, bends, clamps m 6.1 387.760 2365
and nails etc. all complete in all floors (Aziz / Lira / National / Polymer or equivalent water grade PVC Pipe) as per direction of the E-I-C.

62 Building
5.04.03.01.2
Works
Brick work of Kiln 1st class bricks/automatic machine made first class bricks in cement mortar (1:6) in superstructure with Portland Composite cum 11.75 8192.26 96243
cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) with uniform width and depth joints, true to vertical and horizontal lines,
in/c raking out joints, filling interstices tightly with mortar, cleaning and soaking bricks at least for 24 hours before use, washing of sand,
necessary scaffolding, curing for requisite period, etc. all complete as per direction of the E-I-C. Kiln bricks Add for each additional floor up to
5th floor
63 Additional
5.04.10.01.2_
Item
125mm brick work with Kiln 1st class bricks/automatic machine made first class bricks in cement mortar (1:4) with Portland Composite cement sqm 48.44 1215.97 58903
(CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) and making bond with connected walls with uniform width and depth joints, true to
vertical and horizontal lines in/c necessary scaffolding, raking out joints, cleaning and soaking the bricks at least for 24 hours before use,
washing of sand, curing for requisite period, etc. all complete as per direction of the E-I-C. Kiln bricks Add for each additional floor up to 5th
floor
64 Building
5.05.01.03.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 2.931 15192.35 44529
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In pedestal, column, capital lift wall and wall : Add for each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
65 Building
5.05.01.04.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 0.194 13156.39 2552
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Tie Beam and Lintel : Add for each additional floor up to 5th Floor

66 Building
5.05.01.06.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 3.897 13640.95 53159
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In roof slab of all types, cantilever slab and drop panels (excluding floor slab of ground floor at plinth level). Add
for each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
67 Building
5.05.01.07.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 0.084 18070.37 1518
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In sunshade, cornice, railing, drop wall, louver and fins (Average 62mm to 87mm thick) Add for each additional
floor up to 5th Floor

68 Building
5.06.01.01
Works
Supplying and fabrication of Ribbed or deformed bar reinforcement for all types of RCC work including straightening, removing ruts, cleaning, kg 1050 89.18 93632
cutting, hooking, bending, lapping and/or welding wherever required as directed, placing in position, tieing with 22 BWG black annealed binding
wire (PVC coated in case of FBEC rebar) double fold, cost of binding wire and anchoring to the adjoining members wherever necessary,
supplying and placing with proper cover blocks (1:1), supports, chairs, spacers, splices or laps etc. including cost of all materials, cost of
labour, cost of equipment & machinery, loading and unloading, transportation, all other incidental charges and work at all leads and lifts etc. to
complete the work as per design, drawing, specifications and direction of the E-I-C. Measurement relating to nominal mass, dimensions and
tolerances of various types of steel shall conform to relevant BDS/ ASTM codes. Reinforcement shall be measured only in lengths of bar as
actually placed in position on standard weight i.e. 7850 kg/m3 (BNBC Table 6.2.1) basis. No separate payment shall be allowed for Chairs of
any shape & profile, spacer bar of any shape & profile, lap/ splice unless otherwise shown in the drawing, wastages, binding wire, concrete
cover blocks etc. as the cost of these is included in the unit rate. Note: Tests for reinforcing bars shall be conducted at LGED/ BUET/ CUET/
KUET/ RUET. Grade 300 (RB 300): Ribbed or Deformed bar produced and marked as per BDS ISO 6935-2:2006 with minimum yield strength,
fy (ReH) = 300 MPa, but the tested yield strength shall not exceed fy by more than the 125 MPa and the ratio of tested ultimate strength, fu
(Re) to tested yield strength (fy) shall be at least 1.25 and minimum elongation after fracture (A5.65) & minimum total elongation at maximum
force (Agt) is 16% and 2.5% respectively.

69 Building
5.12.01
Works
Minimum 12mm thick cement plaster (1:4) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to sqm 3.672 304.950 1120
dado, plinth wall up to 150mm below ground level, water tank or any where directed with neat cement finishing in/c washing of sand, racking
out joint and picking up cement morter i/c finishing the edges and corners and curing for the requisite period etc. all complete as per direction of
the E-I-C.
70 Building
5.12.02.02
Works
Minimum 12mm thick cement plaster (1:6) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to wall sqm 117.7 269.555 31719
both inner and outer surface, finishing the corner and edges in/c washing of sand cleaning the surface, scaffolding and curing for the requisite
period etc. all complete as per direction of the E-I-C. Add for each additional floor for 5th floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
71 Building
5.12.03.02
Works
Minimum 6mm thick cement plaster (1:4) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to sqm 80.17 251.499 20164
ceiling RCC columns, beams, surface of stair case, sunshades, cornices, railings, drop wall, louvers, fins and finishing the corners and edges
in/c washing of sand cleaning the surface, scaffolding and curing for the requisite period etc. all complete as per direction of the E-I-C. Add for
each additional floor upto 5th floor
72 Building
5.12.22
Works
Plaster rule pointing works 250mmx75mm size as brick shape by 10mmx10mm grove on outside wall over minimum 12mm thick cement sqm 64.32 324.180 20852
plaster (1:6) with Portland Composite cement (CEM II/AM, 42.5N), best quality sand (minimum FM1.2), finishing the corners and edges
including washing of sand, cleaning the surface, scaffolding and curing for requisite period etc. all complete as per drawing and direction of the
E-I-C.
73 Building
5.12.10
Works
Providing drip course/nosing/throating at the edge of sunshade or cornice with cement mortar (1:2) with Portland Composite cement (CEM m 29.06 150.530 4374
II/AM, 42.5N) and best quality sand (minimum FM1.2) in/c. scaffolding, curing at least for 7 days etc. all complete for all floors as per direction
of the E-I-C .
74 Building
5.13.01
Works
25mm thick artificial patent stone floor (1:2:4) with Portland Composite cement (CEM II/AM, 42.5N), best quality coarse sand (minimum FM1.8) sqm 11.92 397.340 4735
and 10mm down well graded picked brick chips (LAA value not exceeding 38) in/c breaking graded picked chips, screening, mixing, laying the
concrete in alternate panels, compacting and finishing the top with neat cement, curing, etc. all complete as per direction of the E-I-C.

75 Building
5.16.05.01
Works
Painting with plastic emulsion paint of best quality and approved colour in a seal container from authorized manufacturer. Applying each coat sqm 138.1 261.310 36078
and successive coat is to be applied as per manufacturer special procedure, to wall and ceiling in two coats over a coat of priming coat of
water sealer and ready mixed putty of approved brand. It applied on sand papered and cleaned surface and after drying applied sealer coat, 2
coats of ready mixed wall putty of approved brand, each coat dried and smoothened by sand papering. Applying plastic emulsion paint one
vertical and one horizontal coat for each coat and successive coat is to be applied after drying up of previous coat by brush/roller/spray in/c
cleaning the plinth, floors, doors, windows, portions and ventilators by washing, rubbing, as necessary and sand papering the surface and
necessary scaffolding, etc. curing for the requisite period etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

76 Building
5.16.09.01
Works
On exterior surface applying as per manufacturer instruction specific coat of weather coat of approved quality and colour delivered from sqm 124.1 277.820 34477
authorized local agent of the manufacturer in a sealed container. Applying one vertical and one horizontal coat for each coat and successive
coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand papering the
surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C. 3 coat

77 Building
5.08.14.02
Works
Supplying, fitting and fixing steel glazed sky light frame (Stair Back fixed Window) at stairs as per design having ?T' section made with flat bar sqm 2.544 3191.600 8119
25mmx3mm as base and 19mmx3mm flat bar as perpendicular at mid of base flat bar welded 200mm c/c grid and Outer frame having
25mmx25mmx3mm MS angle in/c all cost of charges for fabrication and manufacture by welding, riveting, etc. supplying all essential fittings
like 150mm long clamps for fitting frame in/c supplying, fitting, fixing 5mm thick glass panes at grid opening by putty and painting the sky light
with two coats of synthetic enamel paint over a coat of anticorrosive priming, making necessary holes in wall and RCC work as necessary,
filling with CC (1:2:4:) and mending good the damages for all floors, etc. all complete as per direction of the E-I-C and as per drawing and
design.
78 Additional
N.S.I.01
Item
Supplying 4'' pad lock and key in dulicate (China/Globe) as per direction of the E/C each 3 550.10 1650
79 Additional
N.S.I.08
Item
Painting to dado, skirting, out side plinth wall, out side plinth walls painting wall will be from 6'' below GL to plinth level with two coats with sqm 3.672 245.69 902
synthetic enamel black paint of best quality and approve colour over a coat of priming in/c clearing finishing and polishing etc. all complete as
per direction of the Engineer-in-charge.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
80 Building
5.07.03.1
Works
Supplying, fitting and fixing door frame with MS angle (50mmx50mmx6mm), fixing, 250mm long 6 nos. of iron clamps of same size (one end m 10.06 1234.03 12414
bifurcated) with vertical members of the frame, fixing the frame in wall with cement concrete (1:2:4) in Portland Composite cement CEM II/AM,
42.5N), best quality sand (minimum FM1.8) and 20mm down well graded 1st class brick chips, mending good damages, fixing 3 nos. of 100mm
size iron hinges with the vertical members of the frame for single leaf shutter, painting all iron faces in 2 coats over a coat of priming with
enamel paint of approved colour and quality, in/c cutting, sizing, welding for all floors, etc. all complete as per plan and direction of the E-I-C
MS angle 50mmx50mmx6mm size

81 Building
5.08.12.02
Works
Supplying, fitting and fixing combined steel window shutter, frames and grill welded together as per drawing & design having requisite Nos. of sqm 3.342 4098.15 13696
vertical and horizontal standard MS (19mmx19mmx3mm) ?Z' section for shutter and MS flat bar all around (25mmx4.5mm) and (19mmx3mm),
10mm square bar as grill welded horizontally @ 100mm c/c, only catch locking handle position gap should 125mm, at inner face of window
frame with F.I. clamp 75mmx3mm duly embedded with Cement Concrete (1:2:4:) and mending good the damages in/c all cost of charges for
fabrication and manufacture by welding, riveting, etc. supplying all essential fittings like stopper, handle, 3 nos catch hook 300mm long
adjustable iron cleat, 50mm long pin hinge in/c supplying, fitting, fixing 18 BWG M.S. sheet in position welded to steel shutter with Tee stiffener
(2 nos.) made with 25mm and 19mm flat bars fitted to shutter frame in Two equal part and upper part should be provided with 5mm clear glass,
vertically in each shutter panel and putty and painting the window with two coats of synthetic enamel paint over a coat of anticorrosive priming, ,
etc for all floors. all complete as per direction of the E-I-C

82 Building
5.16.10.01
Works
Painting to door and window frames, shutters and any type of MS rod, FI bar, MS box, MS angle grill, gate etc. in two coats with synthetic sqm 8.115 245.69 1994
enamel paint of best quality and approved colour over a coat of priming. Applying one vertical and one horizontal coat for each coat and
successive coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand
papering the surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

83 Building
5.12.17
Works
44mm thick on an average roof top cement concrete screed in proportion (1:1.5:3) with 10mm down graded crushed 1st class brick sqm 103.8 690.530 71662
chips/picked chips, (LAA value not exceeding 38), cement and sand (minimum FM 1.8) including Cement grouting, mixing concrete, laying with
neat cement finishing on the following day of roof slab casting, cost of all materials, labour and transportation to the site, finishing the edges
and corners, curing for the requisite period etc. all complete as per drawing, specification and direction of the E-I-C

84 Building
5.08.20
Works
Supplying fitting and fixing steel door shutter with 18 BWG MS sheet/plain plate hinged to RCC columns reinforcement with sqm 3.246 4588.360 14894
38mmx38mmx5mm MS Angle and 25mmx6mm flat bar stiffener etc. all complete as per drawing and direction of E-I-C.
85 Sanitary,
7.08.05.04
Water
Supplying
Supply
100mm
& Firedia
Fighting
(inside)
Works
best quality PVC rain water down pipes, fitted and fixed in position with sockets head and shoes, bends, clamps m 2.54 387.760 985
and nails etc. all complete in all floors (Aziz / Lira / National / Polymer or equivalent water grade PVC Pipe) as per direction of the E-I-C.

86 Additional
N.S.I.04
Item
Unforeseen Works LS 1 54.00 54
87 Electrical
8.02.06
Works
Sub-distribution board (SDB): Supplying & fitting 250 volt, 50HZ grade following concealed sub-distribution board made of 18 SWG mild steel each 3 7405.20 22216
sheet, complete with hinged type door, built in type locking arrangement, along with approved type handle 200 A capacity bus-bar with required
number of holes there on, insulators at both ends. Copper bar for neutral & earth terminal, necessary arrangement for fixing of SPMCB by
keeping its knobs out on the top cover of the board with enamel/hammer painting. All completes as per specification & direction of the Engineer-
in-Charge.Manufacturer of SPMCB Dorman smith (UK/ Germany) MEM (UK) SIEMENS (USA/Germany) or Equivalent. 12-ways SDBBoxsize-
550mmx500mmx125mmIncoming-1 x 63 A SP MCBOut going- 12 x 6/10/16 A SPMCB
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
88 Electrical
8.04.1.3
Works
Supplying, assembling, fitting, fixing & installation (with effictive connection) on a prepared board 250/500volt grade following single/triple pole each 10 483.080 4831
SPMCB/TPMCB/TPMCCB having minimum breaking capacity 6/10/16KA with thermal over current & instantaneous electromagnetic short
circuit release provision. Manufacturer of SPMCB/TPMCB/TPMCCB (6/10/16 KA) Dorman smith (UK/ Germany) MEM (UK), ABB (Italy),
Legrand (France), Hager (France)/SIEMENS (USA/Germany) or equivalent approved by the Engineer-in-charge. SPMCB (6KA) Manufacturer
of SPMCB/TPMCB/TPMCCB (6/10/16 KA) Dorman smith (UK/ Germany) MEM (UK) SIEMENS (USA/Germany) or equivalent approved by the
Engineer-in-charge. 16 amps (6KA) SPMCB

89 Electrical
8.04.1.4
Works
Supplying, assembling, fitting, fixing & installation (with effictive connection) on a prepared board 250/500volt grade following single/triple pole each 7 483.080 3382
SPMCB/TPMCB/TPMCCB having minimum breaking capacity 6/10/16KA with thermal over current & instantaneous electromagnetic short
circuit release provision. Manufacturer of SPMCB/TPMCB/TPMCCB (6/10/16 KA) Dorman smith (UK/ Germany) MEM (UK), ABB (Italy),
Legrand (France), Hager (France)/SIEMENS (USA/Germany) or equivalent approved by the Engineer-in-charge. SPMCB (6KA) Manufacturer
of SPMCB/TPMCB/TPMCCB (6/10/16 KA) Dorman smith (UK/ Germany) MEM (UK) SIEMENS (USA/Germany) or equivalent approved by the
Engineer-in-charge. 20 amps (6KA) SPMCB

90 Electrical
8.04.1.5
Works
Supplying, assembling, fitting, fixing & installation (with effictive connection) on a prepared board 250/500volt grade following single/triple pole each 6 483.080 2898
SPMCB/TPMCB/TPMCCB having minimum breaking capacity 6/10/16KA with thermal over current & instantaneous electromagnetic short
circuit release provision. Manufacturer of SPMCB/TPMCB/TPMCCB (6/10/16 KA) Dorman smith (UK/ Germany) MEM (UK), ABB (Italy),
Legrand (France), Hager (France)/SIEMENS (USA/Germany) or equivalent approved by the Engineer-in-charge. SPMCB (6KA) Manufacturer
of SPMCB/TPMCB/TPMCCB (6/10/16 KA) Dorman smith (UK/ Germany) MEM (UK) SIEMENS (USA/Germany) or equivalent approved by the
Engineer-in-charge. 32 amps (6KA) SPMCB

91 Electrical
8.05.04.1
Works
ELECTRICAL WIRING Concealed Conduit wiring: Concealed Conduit wiring for the following Points Looping at the Switch board with earth point 42 1326.61 55718
terminal including Circuit wiring with 1c-2x1.5 Sq.mm PVC insulated stranded cable (BYA) & 1.5 Sq.mm (Yellow-green) PVC insulated
stranded ECC wire (BYA) through PVC conduit (Aziz or equivalent) of 25 mm inner dia wall thickness 1.5 mm, 18 SWG GP Sheet, switch
board & Pull box with 3mm thick ebonite sheet cover, brass contact, ceiling rose, fixing materials & all other accessories as required including
mending the damages: Manufacturer of cable Eastern/ BRB/Paradise/Poly cable/Super sign/BBS or equivalent according to the specification &
direction of the Engineer- in-charge. Light point/Exhaust/Wall bracket fan point

92 Electrical
8.05.04.2
Works
ELECTRICAL WIRING Concealed Conduit wiring: Concealed Conduit wiring for the following Points Looping at the Switch board with earth point 29 1485.41 43077
terminal including Circuit wiring with 1c-2x1.5 Sq.mm PVC insulated stranded cable (BYA) & 1.5 Sq.mm (Yellow-green) PVC insulated
stranded ECC wire (BYA) through PVC conduit (Aziz or equivalent) of 25 mm inner dia wall thickness 1.5 mm, 18 SWG GP Sheet, switch
board & Pull box with 3mm thick ebonite sheet cover, brass contact, ceiling rose, fixing materials & all other accessories as required including
mending the damages: Manufacturer of cable Eastern/ BRB/Paradise/Poly cable/Super sign/BBS or equivalent according to the specification &
direction of the Engineer- in-charge. Ceiling fan point

93 Electrical
8.05.09.2
Works
ELECTRICAL WIRING BYA Cable: concealed Conduit wiring with the following PVC insulated stranded cable (BYA) & green Colored PVC m 210 234.01 49142
insulated ECC wire (BYA) through PVC Conduit (Aziz or equivalent) complete with fixing materials & other accessories as specified,
Manufacturer of cable Eastern/BRB/Paradise/Poly cable/Super sign/BBS or equivalent according to the Specification & direction of the
Engineer-in-charge. 1c-2x2.5 Sq.mm (BYA ) Cable with 2.5 Sq.mm (BYA) ECC wire through PVC Pipe of 25 mm inner dia.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
94 Electrical
8.05.09.3
Works
ELECTRICAL WIRING BYA Cable: concealed Conduit wiring with the following PVC insulated stranded cable (BYA) & green Colored PVC m 50 293.39 14670
insulated ECC wire (BYA) through PVC Conduit (Aziz or equivalent) complete with fixing materials & other accessories as specified,
Manufacturer of cable Eastern/BRB/Paradise/Poly cable/Super sign/BBS or equivalent according to the Specification & direction of the
Engineer-in-charge. 1c-2x4.0 Sq.mm (BYA ) Cable with 4.0 Sq.mm (BYA) ECC wire through PVC Pipe of 25 mm inner dia.

95 Electrical
8.06.4.1
Works
Supplying, assembling, fitting, fixing & installation (with effictive connection) of 250 volts single phase 3-pin combined switches and socket each 15 577.03 8655
outlet (Gang type) foreign made MK/Legrand/Hager (Stylea)/ABB/MEM or equivalent brand, mounted on best quality locally made required size
18 SWG galvanized plain sheet board (75mm depth) etc. all complete as per drawings and directions of the E-I-C. 13 amps, Flat pin type

96 Electrical
8.06.4.2
Works
Supplying, assembling, fitting, fixing & installation (with effictive connection) of 250 volts single phase 3-pin combined switches and socket each 1 705.26 705
outlet (Gang type) foreign made MK/Legrand/Hager (Stylea)/ABB/MEM or equivalent brand, mounted on best quality locally made required size
18 SWG galvanized plain sheet board (75mm depth) etc. all complete as per drawings and directions of the E-I-C. 15 amps, Round pin type

97 Electrical
8.06.5.02
Works
Gang switch & socket: Supplying, assembling, fitting, fixing & installation (with effictive connection) on prepared board 250 volt 5 amp each 22 503.28 11072
concealed type switch/socket with switch (foreign made MK/Legrand/ Hager (Stylea)/ABB /MEM or equivalent brand) mounted on 18 SWG
galvanized sheet board 75mm depth with other accessories as per drawing, specification & direction of the Engineer-in-charge.. 02- gang
switch
98 Electrical
8.06.5.06
Works
Gang switch & socket: Supplying, assembling, fitting, fixing & installation (with effictive connection) on prepared board 250 volt 5 amp each 29 671.64 19478
concealed type switch/socket with switch (foreign made MK/Legrand/ Hager (Stylea)/ABB /MEM or equivalent brand) mounted on 18 SWG
galvanized sheet board 75mm depth with other accessories as per drawing, specification & direction of the Engineer-in-charge.. Fan regulator(
gang type)
99 Electrical
8.08.4.2
Works
Supplying all materials as per requirement of power development board for service connection from PDB pole to the desired structure and any LS 1 25000.001 25000
other charges (e.g. security deposit, connection fee, meter installation, testing fee) required by the power development board for supply of
power to the desired structure through underground cable/overhead line etc. complete as per direction of the E-I-C. For 1-phase

100 Electrical
8.09.1.1
Works
Supplying, fitting and fixing 250V capacitor type ceiling fan complete with concealed condensers, canopies and required length of rods, ceiling each 29 4070.27 118038
roses, wooden round blocks, regulator, switches and required length of flexible wire etc.. all complete as per drawings and directions of the E-I-
C. Brand:BRB/Energypac or equivalent approved by Engineer in charge 1.422m sweep (best quality)

101 Electrical
8.11.3.09
Works
Supplying, fitting and fixing the following electric lamp for garden/gate/room light and different places as per directions of the E-I-C. Energy each 13 380.89 4952
Savings Lamp (CLF) 23 watt Spiral Screw Type lamps E-27
102 Additional
8.10.66_
Item
Slim Panel Light-4ft (36 Watt-LED): each Slim Panel Light-4ft (LED16.000 1.00 16.000Supplying , delivering , fitting, fixing, installation (with36 each 29 1160.47 33654
Wett effective connection) testing & Commissioning of 36W LEDSlim Panel Light- 4ft(feet) of following Manufacturers o having length 1200mm
& width 75mm, consisting ofDiffuser-Poly Carbonate & Heat Sink Aluminum housing, input Voltage 220V to 240V(AC), Operating Voltag 150V
to 265V(AC), Power Ratting of 36W, Operating Frequency-50/60 HZ, CCT-6500K, Efficacy-75 LM/Wnecessary wiring with stranded PVC cable
insulated flexible cable with all other accessories as per samp approved by the E-I-Brand: Energypac /Saif Powertec or equivalent approved
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
103 Electrical
8.10.01
Works
Saucer Light : Supplying, assembling, fitting, fixing & installation (with effictive connection) the special type single lamp lock type saucer light set 13 7179.48 93333
fitting of following manufacturers consisting of golden/anodized brass carrier of minimum 250mm dia designed glass of min. height 100mm
suitable for carrier, brass holder, earth terminal, necessary wiring with 2x0.4sq.mm stranded PVC insulated flexible FR cable, compatible for
23/26 W CFl etc. complete (except lamp) of the following model & as per sample approved by the Engineer-in-charge Asha cat No. ACSP-
2816 or Anyasha cat No.ACCMS-71 or Crescent cat No. CPC-29-CP-29 or Gloria cat No. GCF-689 Ring or Shwash cat No. SCCF-12/28 or
equivalent approved by the Engineer-in-charge.

104 Building
5.04.03.01.2
Works
Brick work of Kiln 1st class bricks/automatic machine made first class bricks in cement mortar (1:6) in superstructure with Portland Composite cum 3.824 8192.26 31327
cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) with uniform width and depth joints, true to vertical and horizontal lines,
in/c raking out joints, filling interstices tightly with mortar, cleaning and soaking bricks at least for 24 hours before use, washing of sand,
necessary scaffolding, curing for requisite period, etc. all complete as per direction of the E-I-C. Kiln bricks Add for each additional floor up to
5th floor
105 Additional
5.04.10.01.2_
Item
125mm brick work with Kiln 1st class bricks/automatic machine made first class bricks in cement mortar (1:4) with Portland Composite cement sqm 91.2 1215.97 110899
(CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) and making bond with connected walls with uniform width and depth joints, true to
vertical and horizontal lines in/c necessary scaffolding, raking out joints, cleaning and soaking the bricks at least for 24 hours before use,
washing of sand, curing for requisite period, etc. all complete as per direction of the E-I-C. Kiln bricks Add for each additional floor up to 5th
floor
106 Building
5.05.01.03.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 7.552 15192.35 114733
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In pedestal, column, capital lift wall and wall : Add for each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
107 Building
5.05.01.04.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 1.954 13156.39 25708
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Tie Beam and Lintel : Add for each additional floor up to 5th Floor

108 Building
5.05.01.05.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 8.228 13834.44 113830
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Tee Beam, Ell Beam, Rectangular Beam etc. (exposed breadth and width of ribs to be measured only). Add for
each additional floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
109 Building
5.05.01.06.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 22.16 13640.95 302324
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In roof slab of all types, cantilever slab and drop panels (excluding floor slab of ground floor at plinth level). Add
for each additional floor up to 5th Floor

110 Building
5.05.01.07.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 0.585 18070.37 10571
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In sunshade, cornice, railing, drop wall, louver and fins (Average 62mm to 87mm thick) Add for each additional
floor up to 5th Floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
111 Building
5.05.01.08.2
Works
RCC:1:2:4, 17MPa, Brick Chips (BC): Reinforced cement concrete works with minimum cement content relates to mix ratio (tentative 1:2:4) cum 3.404 13934.64 47434
and maximum water cement ratio 0.45 having minimum required average strength, f'cr = 24 Mpa and satisfied a specified compressive
strength f'c = 17 Mpa at 28 days on standard cylinders as per standard practice of Code AASHTO/ ASTM and Portland Composite Cement
conforming to BDS EN 197-1 : 2003 CEM-II 42.5N sand of minimum FM 1.8 and 20mm down well graded picked brick chips (LAA value and
maximum water absorption not exceeding 38 and 15% respectively) conforming to ASTM C 33 or Aggregate Grading Appendix-3 LGED
Schedule of Rates or any other International recognized envelop in/c breaking chips and screening through proper sieves, centering, shuttering
in position, making shuttering fully leak proof & shuttering with plain 16 BWG steel sheet fitted over 38mm thick wooden plank panels and
Standard size Bamboo Props suitably braced, placing of reinforcement in position, mixing the aggregates with standard mixer machine with
hoper, fed by standard measuring boxes, maintaining allowable slump of 50mm (without plasticizer) & 75mm to 100mm (when plasticizer use),
pouring, casting, compacting by mechanical vibrator machine and curing at least for 28 days, removing centering-shuttering after approved
specified time period, i/c cost of additional testing charges of materials and cylinders required. Excluding the cost of reinforcement and its
fabrication, welding, coupling, placing, binding etc. Additional quantity of cement and Plasticizer i.e. Water reducing chemical admixture of
complying type A under ASTM C 494 to reduce mixing water required for normal workability and to maintain low water-cement (W/C) ratio
(Doses of admixture to be fixed by the mix design from approved laboratory instruction by the Engineer) Additional quantity of cement to be
added if required to attain the strength at the contractor's own cost) etc. all complete as per direction and approval of the Engineer in charge.
Note : Using Concrete Mixer. In Stair case slab and step Add for each additional floor up to 5th Floor

112 Building
5.06.01.01
Works
Supplying and fabrication of Ribbed or deformed bar reinforcement for all types of RCC work including straightening, removing ruts, cleaning, kg 7363 89.18 656633
cutting, hooking, bending, lapping and/or welding wherever required as directed, placing in position, tieing with 22 BWG black annealed binding
wire (PVC coated in case of FBEC rebar) double fold, cost of binding wire and anchoring to the adjoining members wherever necessary,
supplying and placing with proper cover blocks (1:1), supports, chairs, spacers, splices or laps etc. including cost of all materials, cost of
labour, cost of equipment & machinery, loading and unloading, transportation, all other incidental charges and work at all leads and lifts etc. to
complete the work as per design, drawing, specifications and direction of the E-I-C. Measurement relating to nominal mass, dimensions and
tolerances of various types of steel shall conform to relevant BDS/ ASTM codes. Reinforcement shall be measured only in lengths of bar as
actually placed in position on standard weight i.e. 7850 kg/m3 (BNBC Table 6.2.1) basis. No separate payment shall be allowed for Chairs of
any shape & profile, spacer bar of any shape & profile, lap/ splice unless otherwise shown in the drawing, wastages, binding wire, concrete
cover blocks etc. as the cost of these is included in the unit rate. Note: Tests for reinforcing bars shall be conducted at LGED/ BUET/ CUET/
KUET/ RUET. Grade 300 (RB 300): Ribbed or Deformed bar produced and marked as per BDS ISO 6935-2:2006 with minimum yield strength,
fy (ReH) = 300 MPa, but the tested yield strength shall not exceed fy by more than the 125 MPa and the ratio of tested ultimate strength, fu
(Re) to tested yield strength (fy) shall be at least 1.25 and minimum elongation after fracture (A5.65) & minimum total elongation at maximum
force (Agt) is 16% and 2.5% respectively.

113 Building
5.12.01
Works
Minimum 12mm thick cement plaster (1:4) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to sqm 11.33 304.950 3454
dado, plinth wall up to 150mm below ground level, water tank or any where directed with neat cement finishing in/c washing of sand, racking
out joint and picking up cement morter i/c finishing the edges and corners and curing for the requisite period etc. all complete as per direction of
the E-I-C.
114 Building
5.12.02.02
Works
Minimum 12mm thick cement plaster (1:6) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to wall sqm 299.6 269.555 80753
both inner and outer surface, finishing the corner and edges in/c washing of sand cleaning the surface, scaffolding and curing for the requisite
period etc. all complete as per direction of the E-I-C. Add for each additional floor for 5th floor
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
115 Building
5.12.03.02
Works
Minimum 6mm thick cement plaster (1:4) with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) to sqm 387.2 251.499 97373
ceiling RCC columns, beams, surface of stair case, sunshades, cornices, railings, drop wall, louvers, fins and finishing the corners and edges
in/c washing of sand cleaning the surface, scaffolding and curing for the requisite period etc. all complete as per direction of the E-I-C. Add for
each additional floor upto 5th floor
116 Building
5.12.10
Works
Providing drip course/nosing/throating at the edge of sunshade or cornice with cement mortar (1:2) with Portland Composite cement (CEM m 49.33 150.530 7425
II/AM, 42.5N) and best quality sand (minimum FM1.2) in/c. scaffolding, curing at least for 7 days etc. all complete for all floors as per direction
of the E-I-C .
117 Building
5.12.22
Works
Plaster rule pointing works 250mmx75mm size as brick shape by 10mmx10mm grove on outside wall over minimum 12mm thick cement sqm 66.05 324.180 21413
plaster (1:6) with Portland Composite cement (CEM II/AM, 42.5N), best quality sand (minimum FM1.2), finishing the corners and edges
including washing of sand, cleaning the surface, scaffolding and curing for requisite period etc. all complete as per drawing and direction of the
E-I-C.
118 Building
5.13.01
Works
25mm thick artificial patent stone floor (1:2:4) with Portland Composite cement (CEM II/AM, 42.5N), best quality coarse sand (minimum FM1.8) sqm 188.8 397.340 75031
and 10mm down well graded picked brick chips (LAA value not exceeding 38) in/c breaking graded picked chips, screening, mixing, laying the
concrete in alternate panels, compacting and finishing the top with neat cement, curing, etc. all complete as per direction of the E-I-C.

119 Building
5.16.05.01
Works
Painting with plastic emulsion paint of best quality and approved colour in a seal container from authorized manufacturer. Applying each coat sqm 513.2 261.310 134103
and successive coat is to be applied as per manufacturer special procedure, to wall and ceiling in two coats over a coat of priming coat of
water sealer and ready mixed putty of approved brand. It applied on sand papered and cleaned surface and after drying applied sealer coat, 2
coats of ready mixed wall putty of approved brand, each coat dried and smoothened by sand papering. Applying plastic emulsion paint one
vertical and one horizontal coat for each coat and successive coat is to be applied after drying up of previous coat by brush/roller/spray in/c
cleaning the plinth, floors, doors, windows, portions and ventilators by washing, rubbing, as necessary and sand papering the surface and
necessary scaffolding, etc. curing for the requisite period etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

120 Building
5.16.09.01
Works
On exterior surface applying as per manufacturer instruction specific coat of weather coat of approved quality and colour delivered from sqm 239.6 277.820 66567
authorized local agent of the manufacturer in a sealed container. Applying one vertical and one horizontal coat for each coat and successive
coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand papering the
surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C. 3 coat

121 Additional
N.S.I.01
Item
Supplying 4'' pad lock and key in dulicate (China/Globe) as per direction of the E/C each 6 550.10 3301
122 Additional
N.S.I.08
Item
Painting to dado, skirting, out side plinth wall, out side plinth walls painting wall will be from 6'' below GL to plinth level with two coats with sqm 88.54 245.69 21754
synthetic enamel black paint of best quality and approve colour over a coat of priming in/c clearing finishing and polishing etc. all complete as
per direction of the Engineer-in-charge.
123 Building
5.19.04
Works
Supplying, fitting and fixing stair railing or any where directed made of 50mm dia GI pipe of minimum wall thickness 2.90mm hand rail on top sqm 7.796 4859.720 37886
and 20mm dia GI pipe series of minimum wall thickness 2.1mm-2.2mm provided 50mm c/c parallel to hand rail as per drawing (top and bottom
gap 125mm) fixed with vertical 40mm dia GI pipe post minimum wall thickness 2.65mm @ 900mm c/c which fixed in 6mm thick MS plate angle
cleat (top 75mmx75mm and vertical 75mmx100mm) welded to vertical post fixed to stair concrete with 12mm dia MS royal bolt (4 nos) i/c cost
of fabricating, cutting, bending, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c. cutting grooves in
the R.C.C. or brick work, mending good the damages with C.C. (1:2.4) for all floors etc. all complete as per design and direction of the E-I-C.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
124 Building
5.12.05
Works
Providing black board (3.66mx1.22m/2.44mmx1.22mm or directed size) made of 12mm thick cement sand plaster of proportion (1:3) with sqm 13.4 374.27 5013
Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) on walls finished smooth with cement grouting mixed
with black oxide board paint over the cement finishing etc. all complete as per direction of the E-I-C.

125 Building
5.07.03.1
Works
Supplying, fitting and fixing door frame with MS angle (50mmx50mmx6mm), fixing, 250mm long 6 nos. of iron clamps of same size (one end m 31.68 1234.03 39094
bifurcated) with vertical members of the frame, fixing the frame in wall with cement concrete (1:2:4) in Portland Composite cement CEM II/AM,
42.5N), best quality sand (minimum FM1.8) and 20mm down well graded 1st class brick chips, mending good damages, fixing 3 nos. of 100mm
size iron hinges with the vertical members of the frame for single leaf shutter, painting all iron faces in 2 coats over a coat of priming with
enamel paint of approved colour and quality, in/c cutting, sizing, welding for all floors, etc. all complete as per plan and direction of the E-I-C
MS angle 50mmx50mmx6mm size

126 Building
5.08.03.05
Works
Supplying, fitting and fixing 38mm thick well matured natural seasoned wooden panel door shutters (minimum 250mm wide plank), top, rail and sqm 12.97 8005.55 103848
styles of sections (100mmx38mm), lock rail (125mmx38mm) and bottom rail (225mmx38mm) paneling 38mm thick both sides raised, provided
with best quality 6 nos. 100mm iron hinges, 2 nos. best quality 12mm dia 300mm and 225mm long iron tower and socket bolts 2 nos. heavy
type nickel plated handle, hinge cleats, buffer blocks and finished with sand papering for all floors etc. all complete as per direction of the E-I-C.
(Single/Double leaf. All sizes of wood are finished). Mehagoni wood

127 Building
5.08.12.02
Works
Supplying, fitting and fixing combined steel window shutter, frames and grill welded together as per drawing & design having requisite Nos. of sqm 28.82 4098.15 118125
vertical and horizontal standard MS (19mmx19mmx3mm) ?Z' section for shutter and MS flat bar all around (25mmx4.5mm) and (19mmx3mm),
10mm square bar as grill welded horizontally @ 100mm c/c, only catch locking handle position gap should 125mm, at inner face of window
frame with F.I. clamp 75mmx3mm duly embedded with Cement Concrete (1:2:4:) and mending good the damages in/c all cost of charges for
fabrication and manufacture by welding, riveting, etc. supplying all essential fittings like stopper, handle, 3 nos catch hook 300mm long
adjustable iron cleat, 50mm long pin hinge in/c supplying, fitting, fixing 18 BWG M.S. sheet in position welded to steel shutter with Tee stiffener
(2 nos.) made with 25mm and 19mm flat bars fitted to shutter frame in Two equal part and upper part should be provided with 5mm clear glass,
vertically in each shutter panel and putty and painting the window with two coats of synthetic enamel paint over a coat of anticorrosive priming, ,
etc for all floors. all complete as per direction of the E-I-C

128 Building
5.16.10.01
Works
Painting to door and window frames, shutters and any type of MS rod, FI bar, MS box, MS angle grill, gate etc. in two coats with synthetic sqm 32.43 245.69 7968
enamel paint of best quality and approved colour over a coat of priming. Applying one vertical and one horizontal coat for each coat and
successive coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand
papering the surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

129 Building
5.10.14
Works
Supplying, fitting and fixing verandah drop or ventilation Grill or anywhere as directed made of 10mmX10mm MS square bar series welded to sqm 10.8 4246.36 45839
outer frame made of MS flat bar of size 25mmx3mm having anchoring Clamps of 25mmx25mmx3mm MS Angle @750mm c/c to be embaded
in RCC or Brick work i/c cost of fabricating, cutting, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c.
cutting grooves in the R.C.C. or brick work, mending good the damages with Cement Concrete (1:2.4) for all floors etc. all complete as per
design and direction of the E-I-C.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
130 Building
5.19.08
Works
Supplying, fitting and fixing verandah railing or any where as directed made of 20mm dia GI pipe of minimum wall thickness 2.1mm-2.2mm @ sqm 25.66 4720.09 121094
100mm c/c and 50mm dia GI pipe of minimum wall thickness 2.65mm top in horizontal ways (top and bottom gap 125mm) as per design and
drawing fixed with vertical 800mmx100mmx6mm H type MS plate post @ 900mm c/c which fixed in middle portion 20mm dia GI pipe post in
between 50mmx25mmx5mm FI bar) with provision of 20mm GI pipe of minimum wall thickness 2.1mm-2.2mm passing hole in/c making hole in
MS plate and FI bars in required diameter. All post fixing in floor by 100mmx150mm x 6mm MS base plate with 12mm dia MS royal bolt i/c cost
of fabricating, cutting, welding, painting 2 coats of synthetic enamel paint over a coat of anticorrosive priming in/c. cutting grooves in the R.C.C.
or brick work, mending good the damages with C.C. (1:2.4) for all floors etc. all complete as per design and direction of the E-I-C.

131 Building
5.05.11
Works
Dismantling of existing/damaged RCC work in sub-structure or superstructure works of any type manualy or any other means without any cum 6.448 1500.27 9674
damage in structure and sorting the dismantled materials disposal of unserviceable materials and stacking the serviceable materials properly
for measurment for all floors, Cost of conveying, loading, transportation of unserviceable material accumulated during dismantling operation is
included in this unit rate. The unserviceable material must be disposed at a safe place outside the site premises with minimum traffic disruption
and the procuring entity will not provide any environmentally safe place for disposing the unserviceable materials.etc. all complete as per
direction of the E-I-C.

132 Building
5.04.16
Works
Dismantling of existing/damaged brick work in sub-structure or superstructure works of any type manualy or any other means without any cum 8.528 618.00 5270
damage in structure and sorting the dismantled materials disposal of unserviceable materials and stacking the serviceable materials properly
for measurment for all floors, Cost of conveying, loading, transportation of unserviceable material accumulated during dismantling operation is
included in this unit rate. The unserviceable material must be disposed at a safe place outside the site premises with minimum traffic disruption
and the procuring entity will not provide any environmentally safe place for disposing the unserviceable materials.etc. all complete as per
direction of the E-I-C.

133 Building
5.03.10
Works
Dismantling of existing/damaged cement concrete work in foundation or floor works on any type of works manualy or any other means without cum 8.842 908.82 8036
any damage in structure and sorting the dismantled materials disposal of unserviceable materials and stacking the serviceable materials
properly for measurment for all floors, Cost of conveying, loading, transportation of unserviceable material accumulated during dismantling
operation is included in this unit rate. The unserviceable material must be disposed at a safe place outside the site premises with minimum
traffic disruption and the procuring entity will not provide any environmentally safe place for disposing the unserviceable materials.etc. all
complete as per direction of the E-I-C.

134 Building
5.16.05.02
Works
Painting with plastic emulsion paint of best quality and approved colour in a seal container from authorized manufacturer special procedure, to sqm 558.9 133.87 74826
wall and ceiling in two coats. Applying plastic emulsion paint one vertical and one horizontal coat for each coat and successive coat is to be
applied after drying up of previous coat by brush/roller/spray in/c cleaning the plinth, floors, doors, windows, portions and ventilators by
washing, rubbing, as necessary and sand papering the surface and necessary scaffolding, etc. curing for the requisite period etc. all complete
for all floors i/c cost of all materials as per direction of the E-I-C.

135 Building
5.16.09.02
Works
On exterior surface applying as per manufacturer instruction specific coat of weather coat of approved quality and colour delivered from sqm 133.7 177.27 23695
authorized local agent of the manufacturer in a sealed container. Applying one vertical and one horizontal coat for each coat and successive
coat is to be applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand papering the
surface and necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C. 2 coat
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
136 Additional
CE.01.1.7
Item
Providing and maintenance one project profile signboards of the size not exceeding 1 m x 2 m, to be placed at a suitable place of the site each 1 30265.140 30265
including submission of proposals for the materials of the signboards and text layout to the Engineer for approval which will be positioned as
directed by the Engineer and removing the same on completion of the Works or as instructed by the Engineer.

137 Additional
CE.06.3.1
Item
Supplying and setting Indian marble stone of approved quality, textured and size on walls over 12 mm thick cement sand (F.M. 1.2) mortar sqm 0.766 5459.46 4182
(1:2) including cutting and grinding the marble stone slab/tile setting in position keeping horizontal and vertical alignment correct, filling the
joints with white cement, cutting and grinding the top surface, finishing etc including water, electricity and other charges complete in all respect
accepted by the Engineer. (Cement: CEM-II/A-M) 12 mm thick white/ black Marble stone walling In ground floor

138 Additional
N.S.I.02
Item
Inscribing (writing) the name of the year of establishment and construction of school builiding in Bengal on outside Front face of the building no 1 1181.45 1181
with sand cement mortar of proportion 2:1 including painting the letters with approved quality of paint as per direction (Size of letters shown in
the drawing) asper standard design.
139 Additional
N.S.I.13
Item
Supplying, fitting and fixing in position flag stand with 50mm dia G.I pipe with flag hook and standard size Bangladesh flag Bottom fixed in C.C no 1 1100.00 1100
base in proportion (1:2:4)flag stand painting three coats with approved synthetic Enamel paint over a coat of anticorrosve painting Etc. as per
complete as per drawing design and direction of the Engineer in-charge.
140 Building
5.08.14.02
Works
Supplying, fitting and fixing steel glazed sky light frame (Stair Back fixed Window) at stairs as per design having ?T' section made with flat bar sqm 2.544 3191.600 8119
25mmx3mm as base and 19mmx3mm flat bar as perpendicular at mid of base flat bar welded 200mm c/c grid and Outer frame having
25mmx25mmx3mm MS angle in/c all cost of charges for fabrication and manufacture by welding, riveting, etc. supplying all essential fittings
like 150mm long clamps for fitting frame in/c supplying, fitting, fixing 5mm thick glass panes at grid opening by putty and painting the sky light
with two coats of synthetic enamel paint over a coat of anticorrosive priming, making necessary holes in wall and RCC work as necessary,
filling with CC (1:2:4:) and mending good the damages for all floors, etc. all complete as per direction of the E-I-C and as per drawing and
design.
141 Building
5.16.10.02
Works
Painting to door and window frames, shutters and any type of MS rod, FI bar, MS box, MS angle grill, gate etc. in two coats with synthetic sqm 181.3 130.98 23745
enamel paint of best quality and approved colour. Applying one vertical and one horizontal coat for each coat and successive coat is to be
applied after drying up of previous coat by brush/roller/spray in/c cleaning, washing, rubbing, as necessary and sand papering the surface and
necessary scaffolding, etc. all complete for all floors i/c cost of all materials as per direction of the E-I-C.

142 Building
5.04.14.03.2
Works
Fancy screen (Ornamental Screen) work with different size machine made design blocks with uniform colour, carefully laid in coloured cement sqm 5.442 3017.55 16421
mortar (1:3) in all floors in wall with Portland Composite cement (CEM II/AM, 42.5N) and best quality sand (minimum FM1.2) with uniform
mortar joints, true to vertical and horizontal line including racking out joints, cleaning and soaking the blocks for minimum 24 hours before use
including washing and screening of sand, scaffolding, curing for requisite period etc. complete in all respect including supply of all necessary
materials including cost of water, electricity and other charges etc. all complete as per direction of the E-I-C. Block Size :
150mmx150mmx100mm (MCW-Design No.20/21/27 or equivalent volume & design) Add for each additional floor up to 5th Floor

143 Sanitary,
7.08.05.04
Water
Supplying
Supply100mm
& Firedia
Fighting
(inside)
Works
best quality PVC rain water down pipes, fitted and fixed in position with sockets head and shoes, bends, clamps m 33.3 387.760 12912
and nails etc. all complete in all floors (Aziz / Lira / National / Polymer or equivalent water grade PVC Pipe) as per direction of the E-I-C.

144 Electrical
8.07.2.3.6
Works
Supply and installation of electrolytic annealed copper/PVC single core green earth continuity conductor along with cable in pre-installed m 20 530.99 10620
conduit/cable tray including connection to various metallic parts etc. all complete as per drawings, specifications and direction of the Engineer
of the following : HDBC wire 2 SWG
145 Additional
la.rodSupplying,
Item fitting and fixing of single lightning arrester on the top of the building 300mm long 10mm dia copper rod and clamp with bolts and each 1 1500.00 1500
3mm mounted air spike. Top of the lightning arrester should be soldered and other fittings required etc. all complete in all respects as per
directions of the E-I-C.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
146 Additional
eathing.20ft
Item
Earthing the electrical installation with 40 mm. (1.5'') dia G.I. pipe (Earth electrode) having 6.35 mm. dia hole across the pipe at 305 mm. each 1 24150.57 24151
interval securedly bonded by soldering with 2 nos.of No2 SWG HDBC earth leads with its protection by 20 mm. (3/4'') dia G.I. pipe up-to plinth
level run at a depth of 609.6 mm. (2 ft.) below G.L.up-to main board to be earthed including necessary connecting copper sockets, bolts, nuts,
etc. complete for maintaining earth resistance within 1 ohm.Depth of bottom of main electrode at 6858 mm. (22.5 ft) from GL & length of
electrode 6096 mm. (20 ft).
147 Electrical
8.07.5
Works
Construction of Earthing inspection pit inside measurement 600 mm x 600 mm with 250 mm thick brick in cement morter (1:4) with 100mm each 1 7552.66 7553
thick RCC top slab (1:2:4) with 1% re-inforcement 450 mm dia water sealed CI man-hole cover with locking arrangement including necessary
earth works, site filling and one brick flat soling 75 mm thick (1:3:6) base concrete for making inlet channel & 12mm thick (1:2) cement plaster
with neat finishing etc.all complete up to a depth of .75 meter.
148 Additional
N.S.I.04
Item
Unforeseen Works LS 1 54.00 54
149 Furniture
11.01.06
and
Supply
Fixtures
of High, Low combined Bench with Book shelf for Primary School: (A). High Bench with Book shelf: Size : 1.450m-(L) x set 84 10709.65 899611
0.425m(W)x0.730m(H) with plastic top wall thickness 5mm with side wall 25mm height, wall thickness 5mm, Plastic frame weight 5000 gm,
Vertical Ribs 25 nos, Horizontal Ribs 7 nos ,Rib height 12mm and thickness 4mm, Plastic top rib sunk size: 6 to 8mm dia for provided screw
38mm dia @ 180mm c/c long direction and 75mm c/c short direction fitted with steel frame size: 1.435m x0.372m x0.713m made of 25mm MS
square box , Steel frame for footing bracing made of 38mm MS Square box with same materials, Book shelf fitted with 150mm below top frame
with same materials and 5mm guide Rod 15 nos at back side and 2 nos each at left and right side welded with 25mm x 25mmx 2mm MS Angle
as shown in drawing, Stopper should be anchored by raised thread. (B). Low Bench: Size : 1.395m-(L)x0.305m(W)x0.380m(H) with plastic top
wall thickness 5mm with side wall 25mm height, wall thickness 5mm, Plastic frame weight 3000 gm, Vertical Ribs 21 nos, Horizontal Ribs 7
nos, Rib height 12mm and thickness 4mm, Plastic top rib sunk size 6 to 8mm dia for provided screw 38mm dia @ 180mm c/c long direction
and 75mm c/c short direction fitted with steel frame size: 1.325m x0.270m x0.363m made of 25mm MS square box. Steel frame for footing
bracing made of 38mm MS Square box, Stopper should be anchored by raised thread as shown in the drawing (if provided) including cost of
fabricating, cutting, welding, painting etc. all Complete as per the drawing and direction of the E-I-C. (Rate is inclusive of delivering the furniture
at the selected school). BUET test: Physical strength, Breaking strength of Polypropylene impact co Polymer Plastic frame: i) Hardness, Rock
well, ii) Tensile strength High and Low Bench for every 1000 nos set/pair or part there of one test for each type of comprising average of 2
(Two) sample. all complete

150 Furniture
11.01.07
and
Teacher
Fixtures
Table:Supply Primary school teachers Table as per below specification Table top Raw materials :-Polypropylene Impact Copolymer each 7 7373.14 51612
Plastic Size : - 838mm(L) x 533mm(W) x 775mTable Top: Dimen 838mm(L) x 533mm(W) x 25mm(T) Colour: Deep blue, Brick Red, Black,
Orange Plastic Top Weight : 5000gm Steel tube Specification 25mm x 25mm x1.2mm Steel frame Dimension 785mm(L) x 470mm(W) x
750mm Drawer: Two drawer fixed right side, made by high quality 12mm melamine laminated board with two side covered by 12mm laminated
board and Back side covered by 3mm thick ply wood. Size:300mmx300mm Other Manufacturing and Supplying teachers table will be made of
non-toxic Polypropylene impact Copolymer Plastic and Legs are structure made of ms Round tube -25mm x 1.2mm(22x1.2mm), welded ( 0.5''
weld length @ 2'' c/c continuously through the MS tube), cold bended & formed strictly as per drawing. The frame of table must be cleaned in
07(seven) stage tank with phosphate chemical method pure along with polyester powder coating for pre-head at 230ºC for 22 minutes in heat
heaven for curing the paint. Finishing including assembling of all components and best quality PVC stoppers necessary number and type of
nuts and bolts and packing shall be used as shown in the design. Bottom of legs will be provided with PVC cap/shoe as per drawing. Plastic
frame top installation : The Polypropylene Impact Copolymer plastic frame top will be tied with MS steel frame (25mm X 378MM and
thick1.2mm ) by 1 micron electroplated (No-16) X 4 and 50mm star head Countersunk screw at a distance 75 and 180mm c/c. BUET test:
Physical strength, Breaking strength of Polypropylene impact co Polymer Plastic frame: i) Hardness, Rock well, ii) Tensile strengthAll complete
as per direction of the E-I-C.
Construction of Additional Class Room Amir Hossain Mollah GPS Under PEDP4,Madaripur sadar 846617
Item no.
Group
Item Code Description of Item Measurement
QuantityUnit
Rate 2019 Total
151 Furniture
11.01.08
and
Teacher
Fixtures
Chair:Size 550mm(L)x515mm(W)x850m (H)Chair seat Raw materials :- Polypropylene Impact copolymerChair top Specific on each 7 1983.70 13886
465mm(L)x480mm(W)x425m (H)Plastic weight 174 Chair colour Deep blue, Brick red, black, OrSteel tu, Specification Round tube -25mm x
1.2mm, Steel frame Dimension 550mm(L) x 515mm(W) x 47Manufacturing & Supplying teacher chair made of Polypropylene Impact
Copolymer Plastic and Legs are structure made of MS Round tube -25mm x 1.2mm (22x1.2 mm), welded (0.5'' weld length@2 `` C/C
continuously through the MS tube), cold bended & formed strictly as per drawing. The frame of chair must be cleaned in 07 (seven) stage tank
with phosphate chemical method pure along with polyester powder coating for pre-head at 230ºc for 22 minutes in heat oven for curing the
paint to make the permanentof color of steel frame. Finishing including assembling of all components and best quality PVC stoppers necessary
number and type of nuts and bolts and packing shall be used as shown in the same must be supplied and get approval from Upazila
Engineer/Executive Engineer before manufacturing of the lot. Bottom of legs will be provided with PVC cap/shoe as per drawing BUET test:
Physical strength, Breaking strength of Polypropylene impact co Polymer Plastic frame: i) Hardness, Rock well, ii) Tensile strength All complete
as per direction of the E-I-C.

152 Additional
N.S.I.04
Item
Unforeseen Works LS 1 54.00 54
8562841