Professional Documents
Culture Documents
Infineon Technologies BTS432E2E3062ABUMA1 C122542.en - Fa
Infineon Technologies BTS432E2E3062ABUMA1 C122542.en - Fa
ﮐﺎﺭﺑﺮﺩ
• μﮐﻠﯿﺪ ﺑﺮﻕ ﺳﺎﺯﮔﺎﺭ ﺑﺎ Cﺑﺎ ﺑﺎﺯﺧﻮﺭﺩ ﺗﺸﺨﯿﺼﯽ ﺑﺮﺍﯼ ﺑﺎﺭﻫﺎﯼ ﺯﻣﯿﻨﯽ
12ﻭﻟﺖ ﻭ 24ﻭﻟﺖ DC
• ﺍﻧﻮﺍﻉﺑﺎﺭﻫﺎﯼ ﻣﻘﺎﻭﻣﺘﯽ ،ﺍﻟﻘﺎﯾﯽ ﻭ ﺧﺎﺯﻧﯽ
• ﺟﺎﯾﮕﺰﯾﻦﺭﻟﻪ ﻫﺎﯼ ﺍﻟﮑﺘﺮﻭﻣﮑﺎﻧﯿﮑﯽ ﻭ ﻣﺪﺍﺭﻫﺎﯼ ﮔﺴﺴﺘﻪ
ﺗﻮﺿﯿﺤﺎﺕﮐﻠﯽ
ﺭﻭﯼﻓﻨﺎﻭﺭﯼ ﺗﺮﺍﺷﻪ .ﺍﺭﺍﺉﻪ ﻋﻤﻠﮑﺮﺩﻫﺎﯼ ﺣﻔﺎﻇﺘﯽ SIPMOSﺍﺭﺟﺎﻉ ﺷﺪﻩ ﺑﻪ ﺯﻣﯿﻦ ﻭ ﺑﺎﺯﺧﻮﺭﺩ ﺗﺸﺨﯿﺼﯽ ،ﯾﮑﭙﺎﺭﭼﻪ ﺩﺭ ﺗﺮﺍﺷﻪ ﻫﻮﺷﻤﻨﺪ
CMOSﮐﺎﻧﺎﻝ ﺑﺎ ﭘﻤﭗ ﺷﺎﺭﮊ ،ﻭﺭﻭﺩﯼ ﺳﺎﺯﮔﺎﺭ ﺑﺎ Nﺗﻮﺍﻥ ﻋﻤﻮﺩﯼ FET
Vﻣﻨﻄﻖ
ﺧﺎﺭﺝ ﻣﺤﺪﻭﺩﯾﺖﺑﺮﺍﯼ ﭘﻤﭗﺷﺎﺭﮊ ﻭﻟﺘﺎﮊ
5 ﺑﺪﻭﻥﮔﯿﺮﻩ
ﺩﺭﺟﻪﺣﺮﺍﺭﺕ ﺑﺎﺭﻫﺎind ﺗﻐﯿﯿﺮﺩﻫﻨﺪﻩ ﺳﻄﺢ ﺳﻨﺴﻮﺭ
ﺳﻨﺴﻮﺭ
ﯾﮑﺴﻮﮐﻨﻨﺪﻩ 2ﮐﻪ ﺩﺭ
ﺑﺎﺭﺑﺎﺯ
ﺑﺎﺭ
ﺗﺸﺨﯿﺺ ﻣﻨﻄﻖ ESD
ST4
ﻣﺪﺍﺭﮐﻮﺗﺎﻩ
ﺗﺸﺨﯿﺺ
-
PROFET GND
1
ﺑﺎﺭﮔﯿﺮﯼGND ﺳﯿﮕﻨﺎﻝGND
(1ﺑﺪﻭﻥ ﻧﯿﺎﺯ ﺑﻪ ﺍﺟﺰﺍﯼ ﺧﺎﺭﺟﯽ ،ﺟﺮﯾﺎﻥ ﺑﺎﺭ ﻣﻌﮑﻮﺱ ﺗﻮﺳﻂ ﺑﺎﺭ ﻣﺘﺼﻞ ﻣﺤﺪﻭﺩ ﻣﯽ ﺷﻮﺩ.
(2ﺩﯾﻮﺩ ﺧﺎﺭﺟﯽ ﺍﺿﺎﻓﯽ ﺑﺮﺍﯼ ﺑﺎﺭﻫﺎﯼ ﺍﻟﻘﺎﯾﯽ ﺷﺎﺭﮊ ﺷﺪﻩ ﻣﻮﺭﺩ ﻧﯿﺎﺯ ﺍﺳﺖ
ﺣﺪﺍﮐﺜﺮﺍﻣﺘﯿﺎﺯﺍﺕﺩﺭ ﺗﯽ 25 =jﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ ﻣﮕﺮ ﺍﯾﻨﮑﻪ ﻃﻮﺭ ﺩﯾﮕﺮﯼ ﻣﺸﺨﺺ ﺷﺪﻩ ﺑﺎﺷﺪ
V(3ﺍﺱﺑﺪﻭﻥ DUTﻣﺘﺼﻞ ﺑﻪ ﮊﻧﺮﺍﺗﻮﺭ ﺑﺮ ﺍﺳﺎﺱ ISO 7637-1ﻭ DIN 40839ﺭﺍﻩ ﺍﻧﺪﺍﺯﯼ ﻣﯽ ﺷﻮﺩ
(4ﺩﺳﺘﮕﺎﻩ ﺭﻭﯼ 50mm*50mm*1.5mmﺍﭘﻮﮐﺴﯽ PCB FR4ﺑﺎ )26cmﯾﮏ ﻻﯾﻪμ70 ،ﻣﺘﺮ ﺿﺨﺎﻣﺖ( ﻣﻨﻄﻘﻪ ﻣﺴﯽ ﺑﺮﺍﯼ ﺍﺗﺼﺎﻝ
Vbb. PCBﺑﺪﻭﻥ ﻫﻮﺍﯼ ﺩﻣﯿﺪﻩ ﻋﻤﻮﺩﯼ ﺍﺳﺖ.
ﻭﯾﮋﮔﯽﻫﺎﯼ ﺍﻟﮑﺘﺮﯾﮑﯽ
ﻭﺍﺣﺪ ﺍﺭﺯﺵﻫﺎﯼ ﺳﻤﺒﻞ ﭘﺎﺭﺍﻣﺘﺮﻭ ﺷﺮﺍﯾﻂ
ﺣﺪﺍﮐﺜﺮ ﺗﺎﯾﭗﮐﻨﯿﺪ ﺩﻗﯿﻘﻪ ﺩﺭﺗﯽ 25 =jﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩV،ﻭﻟﺖ ﻣﮕﺮ ﺍﯾﻨﮑﻪ ﻃﻮﺭ ﺩﯾﮕﺮﯼ ﻣﺸﺨﺺ ﺷﺪﻩ ﺑﺎﺷﺪ bb = 12
ﺁ -- 11 9 ﻣﻦ(L )ISO ﺟﺮﯾﺎﻥﺑﺎﺭ ﺍﺳﻤﯽ )ﭘﺎﯾﻪ 3ﺗﺎ (5
ﭘﯿﺸﻨﻬﺎﺩV:ISOﺑﺮ= 0.5ﻭﻟﺖ،ﺗﯽﺳﯽ= 85ﺩﺭﺟﻪ ﺳﺎﻧﺘﯽ ﮔﺮﺍﺩ
mA 1 -- -- ﻣﻦ(ﺑﺎﻻL )GND ﺟﺮﯾﺎﻥﺧﺮﻭﺟﯽ )ﭘﯿﻦ (5ﺩﺭ ﺣﺎﻟﯽ ﮐﻪ GNDﻗﻄﻊ ﯾﺎ
، Vﺑﺎﻻ ﮐﺸﯿﺪ GNDﮐﻪ ﺩﺭ= ،0ﻧﻤﻮﺩﺍﺭ ﺻﻔﺤﻪ 7ﺭﺍ ﺑﺒﯿﻨﯿﺪ ،ﺗﯽﺩﺭﺟﻪ
ﺳﺎﻧﺘﯿﮕﺮﺍﺩj = -40 ... + 150
μﺱ 300 160 50 ﺗﯽﺑﺮ ﺗﺎ 90ﺩﺭﺻﺪVﺧﺎﺭﺝ: ﺯﻣﺎﻥﺭﻭﺷﻦ ﺷﺪﻥ
80 -- 10 ﺧﺎﻣﻮﺵ ﺗﯽ ﺗﺎV%10ﺧﺎﺭﺝ: ﺯﻣﺎﻥﺧﺎﻣﻮﺵ ﺷﺪﻥ
ﺁﺭ،Ω12 =Lﺗﯽﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150
ﭘﺎﺭﺍﻣﺘﺮﻫﺎﯼﻋﻤﻠﯿﺎﺗﯽ
V 42 -- 4.5 (Vﺭﻭﺷﻦ) bb ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150 ﻭﻟﺘﺎﮊﺑﻬﺮﻩ ﺑﺮﺩﺍﺭﯼ(5
V 4.5 -- 2.4 (ﺯﯾﺮ) bb V ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150 ﺧﺎﻣﻮﺷﯽﮐﻢ ﻭﻟﺘﺎﮊ
V 4.5 -- -- (ﺍﻭﻟﯿﻦ ﺑﺎﺭ) bb V ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150 ﺭﺍﻩﺍﻧﺪﺍﺯﯼ ﻣﺠﺪﺩ ﮐﻢ ﻭﻟﺘﺎﮊ
V 7.5 6.5 -- bb)ucp(V ﺭﺍﻩﺍﻧﺪﺍﺯﯼ ﻣﺠﺪﺩ ﭘﻤﭗ ﺷﺎﺭﮊ ﮐﻢ ﻭﻟﺘﺎﮊ
ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150 ﻧﻤﻮﺩﺍﺭﺻﻔﺤﻪ 12ﺭﺍ ﺑﺒﯿﻨﯿﺪ
V -- 0.2 -- (ﺯﯾﺮ) bb ∆V ﻫﯿﺴﺘﺮﺯﯾﺲﮐﻢ ﻭﻟﺘﺎﮊ
∆(Vﺯﯾﺮ) (V=bbﺍﻭﻟﯿﻦ ﺑﺎﺭ) (V-bbﺯﯾﺮ) bb
V 52 -- 42 (Vﺑﯿﺶ ﺍﺯ ﺣﺪ) bb ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150 ﺧﺎﻣﻮﺷﯽﺍﺿﺎﻓﻪ ﻭﻟﺘﺎﮊ
V -- -- 42 (Vﺍﻭﻟﯿﻦ) bb ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150 ﺭﺍﻩﺍﻧﺪﺍﺯﯼ ﻣﺠﺪﺩ ﺍﺿﺎﻓﻪ ﻭﻟﺘﺎﮊ
V -- 0.2 -- ∆(Vﺑﯿﺶ ﺍﺯ ﺣﺪ) bb ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150 ﻫﯿﺴﺘﺮﺯﯾﺲﺍﺿﺎﻓﻪ ﻭﻟﺘﺎﮊ
V -- -- 60 (bb )AZ V ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ﻣﺠﺎﺯ(6 ﻣﺤﺎﻓﻈﺖﺩﺭ ﻣﻘﺎﺑﻞ ﻭﻟﺘﺎﮊ ﺑﯿﺶ ﺍﺯ ﺣﺪ
μﺁ 25 12 -- ﻣﻦ(ﺧﺎﻣﻮﺵ) bb ﺳﺎﻧﺘﯿﮕﺮﺍﺩ: ﺗﯽ 25 + ... 40-=jﺩﺭﺟﻪ ﺟﺮﯾﺎﻥﺁﻣﺎﺩﻩ ﺑﻪ ﮐﺎﺭ )ﭘﯿﻦ (3
60 18 -- ﺗﯽ 150=jﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ: Vﮐﻪ ﺩﺭ=0
μﺁ -- 6 -- (ﺧﺎﻣﻮﺵ) L ﻣﻦ ﺟﺮﯾﺎﻥﺧﺮﻭﺟﯽ ﻧﺸﺘﯽ )ﺷﺎﻣﻞ ﺩﺭﻣﻦ(ﺧﺎﻣﻮﺵ) (bb
Vﮐﻪ ﺩﺭ=0
mA -- 1.1 -- ﻣﻦGND ﺟﺮﯾﺎﻥﻋﻤﻠﯿﺎﺗﯽ )ﭘﯿﻦ V،(7(1ﮐﻪ ﺩﺭ= 5ﻭﻟﺖ
(5ﺩﺭ ﺯﻣﺎﻥ ﺗﻐﺬﯾﻪ ﺍﻓﺰﺍﯾﺶ ﻭﻟﺘﺎﮊ ﺗﺎ 6.5 =bbVﻭﻟﺖ ﻧﻮﻉ ﺑﺪﻭﻥ ﭘﻤﭗ ﺷﺎﺭﮊV،ﺧﺎﺭﺝ≈ 2 -bbVﻭﻟﺖ
(6ﻫﻤﭽﻨﯿﻦ ﺑﺒﯿﻨﯿﺪVﺭﻭﺷﻦ )(CLﺩﺭ ﺟﺪﻭﻝ ﺗﻮﺍﺑﻊ ﺣﻔﺎﻇﺘﯽ ﻭ ﻧﻤﻮﺩﺍﺭ ﻣﺪﺍﺭ ﺻﻔﺤﻪ .7ﺍﻧﺪﺍﺯﻩ ﮔﯿﺮﯼ ﺑﺪﻭﻥ ﺑﺎﺭ (7 .ﺍﺿﺎﻓﻪ ﮐﺮﺩﻥﻣﻦ ،STﺍﮔﺮﻣﻦST
< ،0ﺍﺿﺎﻓﻪ ﮐﻨﯿﺪﻣﻦﮐﻪ ﺩﺭ ،ﺍﮔﺮVﮐﻪ ﺩﺭ< 5.5ﻭﻟﺖ
ﺗﻮﺍﺑﻊﺣﻔﺎﻇﺘﯽ(8
ﻣﻦ(L )SCp ﺣﺪﺍﮐﺜﺮﺣﺪ ﻣﺠﺎﺯ ﺟﺮﯾﺎﻥ ﺍﺗﺼﺎﻝ ﮐﻮﺗﺎﻩ ﺍﻭﻟﯿﻪ )ﭘﺎﯾﻪ 3ﺗﺎ ) ،(9(5
ﺣﺪﺍﮐﺜﺮ Vμ400ﺍﮔﺮ sﺑﺮ< Vﺭﻭﺷﻦ )((SC
ﺁ 74 -- -- ﺗﯽ 40-=jﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ:
ﻭﯾﮋﮔﯽﻫﺎﯼ ﺗﺸﺨﯿﺼﯽ
mA 900 -- 2 ﻣﻦ ﺗﯽ 40-=jﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ: ﺟﺮﯾﺎﻥﺗﺸﺨﯿﺺ ﺑﺎﺭ ﺭﺍ ﺑﺎﺯ ﮐﻨﯿﺪ
750 -- 2
ﺭﻭﺩﻩ ﺑﺮ ﺷﺪﻥ ﺍﺯ ﺧﻨﺪﻩ(
(8ﺗﻮﺍﺑﻊ ﺣﻔﺎﻇﺖ ﯾﮑﭙﺎﺭﭼﻪ ﺑﺮﺍﯼ ﺟﻠﻮﮔﯿﺮﯼ ﺍﺯ ﺗﺨﺮﯾﺐ ICﺩﺭ ﺷﺮﺍﯾﻂ ﺧﻄﺎ ﮐﻪ ﺩﺭ ﺑﺮﮔﻪ ﺩﺍﺩﻩ ﺗﻮﺿﯿﺢ ﺩﺍﺩﻩ ﺷﺪﻩ ﺍﺳﺖ ،ﻃﺮﺍﺣﯽ ﺷﺪﻩ ﺍﻧﺪ .ﺷﺮﺍﯾﻂ
ﺧﻄﺎﺑﻪ ﻋﻨﻮﺍﻥ "ﺧﺎﺭﺝ" ﻣﺤﺪﻭﺩﻩ ﻋﻤﻠﮑﺮﺩ ﻋﺎﺩﯼ ﺩﺭ ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﻣﯽ ﺷﻮﺩ .ﻋﻤﻠﮑﺮﺩﻫﺎﯼ ﺣﻔﺎﻇﺘﯽ ﺑﺮﺍﯼ ﻋﻤﻠﯿﺎﺕ ﺗﮑﺮﺍﺭﯼ ﻣﺪﺍﻭﻡ ﻃﺮﺍﺣﯽ ﻧﺸﺪﻩ
ﺍﻧﺪ.
(9ﺣﺪ ﻣﺠﺎﺯ ﺟﺮﯾﺎﻥ ﺍﺗﺼﺎﻝ ﮐﻮﺗﺎﻩ ﺑﺮﺍﯼ ﺣﺪﺍﮐﺜﺮ .ﻣﺪﺕ ﺯﻣﺎﻥ (μ400ﻣﺮﺍﺟﻌﻪ ﮐﻨﯿﺪ ( td)SCﺑﻪ ﺻﻔﺤﻪ )4ﻗﺒﻞ ﺍﺯ ﺧﺎﻣﻮﺵ ﺷﺪﻥ s،
(10ﺩﺭ ﺣﺎﻟﯽ ﮐﻪ ﻣﻐﻨﺎﻃﯿﺲ ﺯﺩﺍﯾﯽ ﺍﻧﺪﻭﮐﺘﺎﻧﺲ ﺑﺎﺭ ،ﺍﻧﺮﮊﯼ ﺗﻠﻒ ﺷﺪﻩ ﺩﺭ PROFETﺍﺳﺖV AS=Eﺭﻭﺷﻦ )*(CLﻣﻦLﺗﻘﺮﯾﺒﺎ )t( dt،
Vﺭﻭﺷﻦ )(CL
( ،ﻧﻤﻮﺩﺍﺭ ﺻﻔﺤﻪ 8ﺭﺍ ﺑﺒﯿﻨﯿﺪ. *L*2/1AS=Eﻣﻦ)*L2
Vﺭﻭﺷﻦ )bbV-(CL
11ﺟﺮﯾﺎﻥ ﺑﺎﺭ ﻣﻌﮑﻮﺱ )ﺍﺯ ﻃﺮﯾﻖ ﺩﯾﻮﺩ ﻣﻨﺒﻊ ﺗﺨﻠﯿﻪ ﺫﺍﺗﯽ( ﻣﻌﻤﻮﻻ ًﺗﻮﺳﻂ ﺑﺎﺭ ﻣﺘﺼﻞ ﻣﺤﺪﻭﺩ ﻣﯽ ﺷﻮﺩ .ﺟﺮﯾﺎﻥ ﻣﻌﮑﻮﺱ GNDIﺍﺯ≈ Vﺩﺭ 0.3 A
32- =bbﻭﻟﺖ ﺍﺯ ﻃﺮﯾﻖ ﻣﻨﻄﻖ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﮔﺮﻡ ﻣﯽ ﮐﻨﺪ .ﺯﻣﺎﻥ ﻣﺠﺎﺯ ﺩﺭ ﺍﯾﻦ ﺷﺮﺍﯾﻂ ﺑﻪ ﺍﻧﺪﺍﺯﻩ ﻫﯿﺖ ﺳﯿﻨﮏ ﺑﺴﺘﮕﯽ ﺩﺍﺭﺩ .ﻣﻌﮑﻮﺱ I
GNDﻣﯽ ﺗﻮﺍﻥ ﺑﺎ ﯾﮏ ﻣﻘﺎﻭﻣﺖ GNDﺧﺎﺭﺟﯽ ﺍﺿﺎﻓﯽ ﮐﺎﻫﺶ ﺩﺍﺩ )Ω(.150ﺟﺮﯾﺎﻥ ﻭﺭﻭﺩﯼ ﻭ ﻭﺿﻌﯿﺖ ﺑﺎﯾﺪ ﻣﺤﺪﻭﺩ ﺑﺎﺷﺪ )ﺑﻪ ﺣﺪﺍﮐﺜﺮ
ﺭﺗﺒﻪﺑﻨﺪﯼ ﺻﻔﺤﻪ 2ﻭ ﻣﺪﺍﺭ ﺻﻔﺤﻪ 7ﻣﺮﺍﺟﻌﻪ ﮐﻨﯿﺪ(.
ﻭﺿﻌﯿﺖ(12 ﺑﺎﺯﺧﻮﺭﺩﻭﺭﻭﺩﯼ ﻭ
V 2.4 -- 1.5 (IN )T+ V ﻭﻟﺘﺎﮊﺁﺳﺘﺎﻧﻪ ﺭﻭﺷﻦ ﺷﺪﻥ ﻭﺭﻭﺩﯼ
ﺗﯽ 150+..40-=jﺩﺭﺟﻪ ﺳﺎﻧﺘﯽ ﮔﺮﺍﺩ:
V -- -- 1.0 (IN )T- V ﻭﻟﺘﺎﮊﺁﺳﺘﺎﻧﻪ ﺧﺎﻣﻮﺵ ﺷﺪﻥ ﻭﺭﻭﺩﯼ
ﺗﯽ 150+..40-=jﺩﺭﺟﻪ ﺳﺎﻧﺘﯽ ﮔﺮﺍﺩ:
μﺁ 50 25 10 ﻣﻦ(ﺭﻭﺷﻦ) IN Vﮐﻪ ﺩﺭ= 3.5ﻭﻟﺖ: ﺟﺮﯾﺎﻥﻭﺭﻭﺩﯼ ﻭﺿﻌﯿﺖ )ﭘﯿﻦ (2
μﺱ 400 200 80 ﺗﯽ(d )ST SC ﻭﺿﻌﯿﺖﭘﺲ ﺍﺯ ﺷﯿﺐ ﻭﺭﻭﺩﯼ ﻣﺜﺒﺖ ﻧﺎﻣﻌﺘﺒﺮ ﺍﺳﺖ
ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯽ ﮔﺮﺍﺩ j=-40 ... +150 )ﻣﺪﺍﺭ ﮐﻮﺗﺎﻩ(
μﺱ 1600 - - 350 ﺗﯽ(d )ST ﻭﺿﻌﯿﺖﭘﺲ ﺍﺯ ﺷﯿﺐ ﻭﺭﻭﺩﯼ ﻣﺜﺒﺖ ﻧﺎﻣﻌﺘﺒﺮ ﺍﺳﺖ
ﺗﯽ:ﺩﺭﺟﻪ ﺳﺎﻧﺘﯽ ﮔﺮﺍﺩ j=-40 ... +150 )ﺑﺎﺭ ﺑﺎﺯ(
ﺧﺮﻭﺟﯽﻭﺿﻌﯿﺖ )ﺗﺨﻠﯿﻪ ﺑﺎﺯ(
V -- 6.1 5.4 V
(ﺑﺎﻻ) ST ﻭﻟﺘﺎﮊﺣﺪﯼ ﺯﻧﺮﺗﯽ،ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150ﻣﻦ 1.6+ =STﻣﯿﻠﯽ ﺁﻣﭙﺮ :ﻭﻟﺘﺎﮊ
0.4 -- -- (Vﮐﻢ) ST ﭘﺎﯾﯿﻦSTﺗﯽ،ﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ j = -40 ... + 150ﻣﻦ 1.6+ =STﻣﯿﻠﯽ ﺁﻣﭙﺮ:
(12ﺍﮔﺮ ﯾﮏ ﻣﻘﺎﻭﻣﺖ ﺯﻣﯿﻦ GNDRﺍﺳﺘﻔﺎﺩﻩ ﻣﯽ ﺷﻮﺩ ،ﺍﻓﺖ ﻭﻟﺘﺎﮊ ﺭﺍ ﺩﺭ ﺍﯾﻦ ﻣﻘﺎﻭﻣﺖ ﺍﺿﺎﻓﻪ ﮐﻨﯿﺪ.
ﺟﺪﻭﻝﺩﺭﺳﺘﯽ
ﻭﺿﻌﯿﺖ ﺧﺮﻭﺟﯽ ﻭﺭﻭﺩﯼ-
ﺁﺭ Ibb
ﻣﻦ 3
ﮐﻪﺩﺭ
ﻣﻦﻭﺍﺭﺩ ﺷﺪﻡ
Vbb
ESD- ﮐﻪﺩﺭ
5 +ﻭﻟﺖ
+ Vbb
ﻣﻨﻄﻖ ESD-
V
ﺧﺎﺭﺝ ZD
ST GND
ﺁﺭST
PROFET GND
ﺩﯾﻮﺩ :ESD-Zenerﻧﻮﻉ 6.1ﻭﻟﺖ ،ﺣﺪﺍﮐﺜﺮ 5ﻣﯿﻠﯽ ﺁﻣﭙﺮ؛
ΩRST)ON( >250ﺩﺭ 1.6ﻣﯿﻠﯽ ﺁﻣﭙﺮ ،ﺩﯾﻮﺩﻫﺎﯼ ﺯﻧﺮ ESDﺑﺮﺍﯼ ﺟﺮﯾﺎﻥ
ﺁﺭ GND
ﭘﯿﻮﺳﺘﻪﻃﺮﺍﺣﯽ ﻧﺸﺪﻩ ﺍﻧﺪ
ﺳﯿﮕﻨﺎﻝGND
ﺗﺸﺨﯿﺺﺑﺎﺭ ﺑﺎﺯ
ﻭﺿﻌﯿﺖﺗﺸﺨﯿﺼﯽ V:ON-stateﺑﺮ> ﺁﺭﺑﺮ* ﻣﻦﺭﻭﺩﻩ ﺑﺮ ﺷﺪﻥ ﺍﺯ ﺧﻨﺪﻩ(; ﺩﺭ ﺑﺎﻻ + Vbb
V
+ Vbb ﺑﺮ
ﺧﺎﺭﺝ
ﻣﺪﺍﺭﮐﻮﺗﺎﻩ ﻣﻨﻄﻖ
Vﺑﺮ ﺗﺸﺨﯿﺺ ﻭﺍﺣﺪ
ﺑﺮ
ﺧﺎﺭﺝ
ﺑﺎﺭﺑﺎﺯ ﻣﻨﻄﻖ
ﺗﺸﺨﯿﺺ ﻭﺍﺣﺪ ﮔﯿﺮﻩﺧﺮﻭﺟﯽ ﺍﻟﻘﺎﯾﯽ ﻭ ﺍﺿﺎﻓﻪ ﻭﻟﺘﺎﮊ
+ Vbb
V
ﺯ
V
ﺑﺮ
ﻗﻄﻊﺍﺗﺼﺎﻝ GND
ﺧﺎﺭﺝ
GND
3
ﻫﺮﻧﻮﻉ ﺑﺎﺭ .ﺩﺭ ﺻﻮﺭﺕ Input=high Vﺍﺳﺖﺧﺎﺭﺝ≈Vﮐﻪ ﺩﺭ .IN )T+(- Vﺑﻪ ﺩﻟﯿﻞ V
،0 <GNDﺑﺪﻭﻥ =STVﺳﯿﮕﻨﺎﻝ ﮐﻢ ﺩﺭ ﺩﺳﺘﺮﺱ ﺍﺳﺖ.
3 3
ST ST
4 4
ﻥD
ﺟﯽ GND
1 1
V V
V
GND
V ﺩﺭST V
bb bb
ﻫﺮﻧﻮﻉ ﺑﺎﺭ .ﺍﮔﺮ VGND <Vﮐﻪ ﺩﺭIN )T+(- Vﺩﺳﺘﮕﺎﻩ ﺑﻪ ﺩﻟﯿﻞ Vﺧﺎﻣﻮﺵ ﻣﯽ ﻣﺎﻧﺪ
،0 <GNDﺑﺪﻭﻥ =STVﺳﯿﮕﻨﺎﻝ ﮐﻢ ﺩﺭ ﺩﺳﺘﺮﺱ ﺍﺳﺖ.
ﺍﺗﻼﻑﺍﻧﺮﮊﯼ ﺧﺎﻣﻮﺵ ﮐﻨﻨﺪﻩ ﺑﺎﺭ ﺍﻟﻘﺎﯾﯽ bbVﺑﺎ ﺑﺎﺭ ﺍﻟﻘﺎﯾﯽ ﺷﺎﺭﮊ ﺷﺪﻩ ﻗﻄﻊ ﺷﻮﺩ
ﻓﺮﻭﮐﺶ
EAS 3
ﺑﺎﺭﮔﺬﺍﺭﯼﻣﺠﺪﺩ
bb V ﺑﺎﻻ
ﮐﻪﺩﺭ
ﺧﺎﺭﺝ FETO
5
ﺭﻭﺍﺑﻂﻋﻤﻮﻣﯽ
ER V
bb
E ﻧﺴﺨﻪﻣﻨﻄﻘﯽ
ﻣﺤﺎﻓﻈﺖﺩﺭ ﺑﺮﺍﺑﺮ ﺩﻣﺎﯼ ﺑﯿﺶ ﺍﺯ ﺣﺪ ﺗﯽﺩﺭﺟﻪ
<(16(15j ﺳﺎﻧﺘﯿﮕﺮﺍﺩ،ﻋﻤﻠﮑﺮﺩ ﻗﻔﻞ 150
ﺍﯾﮑﺲ ﺗﯽﺩﺭﺟﻪ ﺳﺎﻧﺘﯿﮕﺮﺍﺩ ،ﺑﺎ ﺭﺍﻩ ﺍﻧﺪﺍﺯﯼ ﻣﺠﺪﺩ ﺧﻮﺩﮐﺎﺭ ﻫﻨﮕﺎﻡ ﺧﻨﮏ ﺷﺪﻥ j< 150
ﻣﺤﺪﻭﺩﯾﺖﻓﻌﻠﯽ ﺑﺎﺭﮔﺬﺍﺭﯼ
ﺍﯾﮑﺲ ﺳﻄﺢﺑﺎﻻ)ﻣﯽ ﺗﻮﺍﻧﺪ ﺑﺎﺭﻫﺎﯼ ﺑﺎ ﺟﺮﯾﺎﻥ ﻫﺎﯼ ﻫﺠﻮﻣﯽ ﺑﺎﻻ ﺭﺍ ﺗﺤﻤﻞ ﮐﻨﺪ(
ﺳﻄﺢﻣﺘﻮﺳﻂ
ﺳﻄﺢﭘﺎﯾﯿﻦ)ﺣﻔﺎﻇﺖ ﺑﻬﺘﺮ ﺍﺯ ﺑﺮﻧﺎﻣﻪ(
(15ﻗﻔﻞ ﺑﺠﺰ ﺯﻣﺎﻧﯽ ﮐﻪV-bbVﺧﺎﺭﺝ>Vﺭﻭﺷﻦ )(SCﭘﺲ ﺍﺯ ﺧﺎﻣﻮﺵ ﺷﺪﻥ ﺩﺭ ﺑﯿﺸﺘﺮ ﻣﻮﺍﺭﺩVﺧﺎﺭﺝ= 0ﻭﻟﺖ ﭘﺲ ﺍﺯ ﺧﺎﻣﻮﺵ ﺷﺪﻥ )Vﺧﺎﺭﺝ≠ ﻓﻘﻂ ﺩﺭ
ﺻﻮﺭﺕﺍﺟﺒﺎﺭ ﺧﺎﺭﺟﯽ( .ﺑﻨﺎﺑﺮﺍﯾﻦ ﺩﺳﺘﮕﺎﻩ ﻗﻔﻞ ﺑﺎﻗﯽ ﻣﯽ ﻣﺎﻧﺪ ﻣﮕﺮ ﺍﯾﻨﮑﻪ V>bbV0 Vﺭﻭﺷﻦ ))(SCﺻﻔﺤﻪ 4ﺭﺍ ﺑﺒﯿﻨﯿﺪ
( .ﺑﺪﻭﻥ ﻗﻔﻞ ﺑﯿﻦ ﺭﻭﺷﻦ ﻭ .d )SC(t
(16ﺑﺎ ﻋﻤﻠﮑﺮﺩ ﻗﻔﻞ .ﺗﻨﻈﯿﻢ ﻣﺠﺪﺩ ﺗﻮﺳﻂ ﺍﻟﻒ( ﻭﺭﻭﺩﯼ ﮐﻢ ،ﺏ( ﻭﻟﺘﺎﮊ ﮐﻢ ،ﺝ( ﺍﺿﺎﻓﻪ ﻭﻟﺘﺎﮊ
(17ﮐﻮﺗﺎﻩ ﻣﻘﺎﻭﻣﺖ ﮐﻢbbVﺑﻪ ﺧﺮﻭﺟﯽ ﻣﻤﮑﻦ ﺍﺳﺖ ﺑﺎ ﺗﺸﺨﯿﺺ ﺑﺪﻭﻥ ﺑﺎﺭ ﺷﻨﺎﺳﺎﯾﯽ ﺷﻮﺩ
ﻧﻤﻮﺩﺍﺭﻫﺎﯼﺯﻣﺎﻥ ﺑﻨﺪﯼ
ﮐﻪﺩﺭ
ﮐﻪﺩﺭ
ﺗﯽ(d )ST
(td )bb IN
V
ST bb
*(
V
ﺧﺎﺭﺝ V
ﺧﺎﺭﺝ
ﺁ
ﺗﯽ ﺗﯽ
ﺁ
ﺗﯽ(IN ﺩﺭﺻﻮﺭﺕ ﺧﯿﻠﯽ ﺯﻭﺩ =VINﺑﺎﻻ ﻣﻤﮑﻦ ﺍﺳﺖ ﺩﺳﺘﮕﺎﻩ ﺭﻭﺷﻦ ﻧﺸﻮﺩ )ﻣﻨﺤﻨﯽ (A
* ( ﺍﮔﺮ ﺛﺎﺑﺖ ﺯﻣﺎﻧﯽ ﺑﺎﺭ ﺧﯿﻠﯽ ﺯﯾﺎﺩ ﺑﺎﺷﺪ ،ﻭﺿﻌﯿﺖ ﺑﺎﺭ ﺑﺎﺯ ﻣﻤﮑﻦ ﺍﺳﺖ ﺭﺥ ﺩﻫﺪ
d )bbﺗﻘﺮﯾﺒﺎ μ150ﺱ
ﮐﻪﺩﺭ ﮐﻪﺩﺭ
ST ST
V V
ﺧﺎﺭﺝ ﺧﺎﺭﺝ
(td )SC
ﻣﻦ ﻣﻦ
L L
ﺗﯽ ﺗﯽ
ﮐﻪﺩﺭ
ﮐﻪﺩﺭ
ﻣﻦ
L
ST
(IL )SCp
(IL )SCr
V
ﺧﺎﺭﺝ
ﺗﯽ
ﺟﯽ ﺗﯽ ST
ﺗﯽ
ﮔﺮﻡﺷﺪﻥ ﻣﻤﮑﻦ ﺍﺳﺖ ﺑﻪ ﭼﻨﺪﯾﻦ ﻣﯿﻠﯽ ﺛﺎﻧﯿﻪ ﻧﯿﺎﺯ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪ- VbbV ،ﺧﺎﺭﺝﻧﻮﻉ > 8.3ﻭﻟﺖ
ﮐﻪﺩﺭ
ﮐﻪﺩﺭ
ﺗﯽ
(d )ST ST ST
V V
ﺧﺎﺭﺝ ﺧﺎﺭﺝ
ﻣﻦ
L ﻣﻦL
ﺑﺎﺯﮐﻦ * *(
ﺗﯽ ﺗﯽ
ﺷﮑﻞ:6bﺭﺍﻩ ﺍﻧﺪﺍﺯﯼ ﻣﺠﺪﺩ ﭘﻤﭗ ﺷﺎﺭﮊ ﮐﻢ ﻭﻟﺘﺎﮊ ﺷﮑﻞ 5ﺏ:ﺑﺎﺭ ﺑﺎﺯ :ﺗﺸﺨﯿﺺ ﺩﺭ ﺣﺎﻟﺖ ﺭﻭﺷﻦ ،ﺑﺎﺭ ﺑﺎﺯ ﺩﺭ ﺣﺎﻟﺖ
ﺭﻭﺷﻦﺭﺥ ﻣﯽ ﺩﻫﺪ
[VON ]V
Vﺭﻭﺷﻦ )(CL V
ﺑﺮ ﮐﻪﺩﺭ
ﺧﺎﻣﻮﺵ
V V
(ﺑﯿﺶ ﺍﺯ ﺣﺪ) bb ﺧﺎﺭﺝ
ﺧﺎﻣﻮﺵ
V V
(ﺍﻭﻟﯿﻦ) bb (ﺍﻭﻟﯿﻦ ﺑﺎﺭ) bb
(ﺯﯾﺮ) bb
V
ﺑﺮ ﺗﯽ
bbV
]V[bbV ﺗﯽ(s typμ= tbdd )ST OL2(s typ., tμ= tbdd )ST OL1
ﭘﻤﭗﺷﺎﺭﮊ ﺍﺯ Vﺷﺮﻭﻉ ﻣﯽ ﺷﻮﺩ( 6.5 =bb)ucpﻭﻟﺖ ﻧﻮﻉ
ﺷﮑﻞ:6aﮐﻢ ﻭﻟﺘﺎﮊ:
ﺷﮑﻞ:7aﺍﺿﺎﻓﻪ ﻭﻟﺘﺎﮊ:
ﮐﻪﺩﺭ
ﮐﻪﺩﺭ
(ﺍﻭﻟﯿﻦ) bb
V (ﺑﯿﺶ ﺍﺯ ﺣﺪ) Vbb ﺭﻭﺷﻦ)(CL
V Vbb
bbV
(Vbb)u cp V
(ﺯﯾﺮ) bb
V
(ﺍﻭﻟﯿﻦ ﺑﺎﺭ) bb
V
ﺧﺎﺭﺝ
Vﺧﺎﺭﺝ
ﺯﻫﮑﺶﺑﺎﺯ ST
ST
ﺗﯽ ﺗﯽ
ﺑﺴﺘﻪﺑﻨﺪﯼ ﻭ ﮐﺪ ﺳﻔﺎﺭﺵ
ﺗﻤﺎﻣﯽﺍﺑﻌﺎﺩ ﺑﺮ ﺣﺴﺐ ﻣﯿﻠﯽ ﻣﺘﺮ
2.4 0.3...0
0.1 0.05
± 0.10.5
2.4
0.15...0
ﺳﯽ
ﺣﺪﺍﮐﺜﺮ 8ﺩﺭﺟﻪ
± 0.10.8 ×5 ± 0.10.5 0.15...0
ﺗﺎﺭﯾﺨﭽﻪﻭﯾﺮﺍﯾﺸﻬﺎﯼ
± 0.310.2
± 0.38.6
0.5±4.7
± 0.32.7
)(15
± 0.310.2 ±9.25
± 0.315.65
± 0.31.3
Rev. 1.1
0.2 ±2.8
(112.95
(17.55
ﻣﻨﺘﺸﺮﺷﺪﻩ ﺗﻮﺳﻂ
ﻣﻮﻧﯿﺦ،ﺁﻟﻤﺎﻥ AG 81726
Infineon Technologies
.ﮐﻠﯿﻪﺣﻘﻮﻕ ﻣﺤﻔﻮﻅ ﺍﺳﺖ AG
© 2010 Infineon Technologies
ﺳﻠﺐﻣﺴﺉﻮﻟﯿﺖ ﺣﻘﻮﻗﯽ
ﺍﻃﻼﻋﺎﺕﺍﺭﺍﺉﻪ ﺷﺪﻩ ﺩﺭ ﺍﯾﻦ ﺳﻨﺪ ﺑﻪ ﻫﯿﭻ ﻭﺟﻪ ﺑﻪ ﻋﻨﻮﺍﻥ ﺗﻀﻤﯿﻨﯽ ﺑﺮﺍﯼ ﺷﺮﺍﯾﻂ ﯾﺎ ﻭﯾﮋﮔﯽ ﻫﺎ ﺩﺭ ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﻧﻤﯽ ﺷﻮﺩ .ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻧﻤﻮﻧﻪ ﻫﺎ ﯾﺎ ﻧﮑﺎﺗﯽ
ﮐﻪﺩﺭ ﺍﯾﻨﺠﺎ ﺁﻭﺭﺩﻩ ﺷﺪﻩ ﺍﺳﺖ ،ﻣﻘﺎﺩﯾﺮ ﻣﻌﻤﻮﻝ ﺫﮐﺮ ﺷﺪﻩ ﺩﺭ ﺍﯾﻨﺠﺎ ﻭ/ﯾﺎ ﻫﺮ ﮔﻮﻧﻪ ﺍﻃﻼﻋﺎﺕ ﻣﺮﺑﻮﻁ ﺑﻪ ﮐﺎﺭﺑﺮﺩ ﺩﺳﺘﮕﺎﻩInfineon Technologies ،
ﺑﺪﯾﻨﻮﺳﯿﻠﻪﻫﺮﮔﻮﻧﻪ ﻭ ﻫﻤﻪ ﺿﻤﺎﻧﺖ ﻫﺎ ﻭ ﺗﻌﻬﺪﺍﺕ ﺍﺯ ﻫﺮ ﻧﻮﻉ ،ﺍﺯ ﺟﻤﻠﻪ ﺑﺪﻭﻥ ﻣﺤﺪﻭﺩﯾﺖ ،ﺿﻤﺎﻧﺖ ﻫﺎﯼ ﻋﺪﻡ ﻧﻘﺾ ﺭﺍ ﺳﻠﺐ ﻣﯽ ﮐﻨﺪ .ﺣﻘﻮﻕ ﻣﺎﻟﮑﯿﺖ
ﻣﻌﻨﻮﯼﻫﺮ ﺷﺨﺺ ﺛﺎﻟﺚ
ﺍﻃﻼﻋﺎﺕ
ﺑﺮﺍﯼﮐﺴﺐ ﺍﻃﻼﻋﺎﺕ ﺑﯿﺸﺘﺮ ﺩﺭ ﻣﻮﺭﺩ ﻓﻨﺎﻭﺭﯼ ،ﺷﺮﺍﯾﻂ ﻭ ﺿﻮﺍﺑﻂ ﺗﺤﻮﯾﻞ ﻭ ﻗﯿﻤﺖ ،ﻟﻄﻔﺎ ًﺑﺎ ﻧﺰﺩﯾﮑﺘﺮﯾﻦ ﺩﻓﺘﺮ ﻓﻨﺎﻭﺭﯼ ) Infineon
. (www.infineon.com
ﻫﺸﺪﺍﺭﻫﺎ
ﺑﻪﺩﻟﯿﻞ ﺍﻟﺰﺍﻣﺎﺕ ﻓﻨﯽ ،ﺍﺟﺰﺍ ﻣﻤﮑﻦ ﺍﺳﺖ ﺣﺎﻭﯼ ﻣﻮﺍﺩ ﺧﻄﺮﻧﺎﮎ ﺑﺎﺷﻨﺪ .ﺑﺮﺍﯼ ﺍﻃﻼﻋﺎﺕ ﺩﺭ ﻣﻮﺭﺩ ﺍﻧﻮﺍﻉ ﻣﻮﺭﺩ ﻧﻈﺮ ،ﻟﻄﻔﺎ ًﺑﺎ ﻧﺰﺩﯾﮑﺘﺮﯾﻦ ﺩﻓﺘﺮ ﻓﻨﺎﻭﺭﯼ
Infineonﺗﻤﺎﺱ ﺑﮕﯿﺮﯾﺪ.
ﺍﺟﺰﺍﯼ Infineon Technologiesﺭﺍ ﻣﯽ ﺗﻮﺍﻥ ﺩﺭ ﺩﺳﺘﮕﺎﻩ ﻫﺎ ﯾﺎ ﺳﯿﺴﺘﻢ ﻫﺎﯼ ﭘﺸﺘﯿﺒﺎﻧﯽ ﺣﯿﺎﺕ ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ ،ﻓﻘﻂ ﺑﺎ ﺗﺄﯾﯿﺪ ﮐﺘﺒﯽ ﺻﺮﯾﺢ
،Infineon Technologiesﺩﺭ ﺻﻮﺭﺗﯽ ﮐﻪ ﺑﻪ ﻃﻮﺭ ﻣﻨﻄﻘﯽ ﺑﺘﻮﺍﻥ ﺍﻧﺘﻈﺎﺭ ﺩﺍﺷﺖ ﮐﻪ ﺧﺮﺍﺑﯽ ﺍﯾﻦ ﻗﻄﻌﺎﺕ ﺑﺎﻋﺚ ﺧﺮﺍﺑﯽ ﺁﻥ ﺩﺳﺘﮕﺎﻩ ﯾﺎ ﺳﯿﺴﺘﻢ
ﭘﺸﺘﯿﺒﺎﻧﯽﺣﯿﺎﺕ ﺷﻮﺩ ﯾﺎ ﺑﺮ ﺍﯾﻤﻨﯽ ﺗﺄﺛﯿﺮ ﺑﮕﺬﺍﺭﺩ .ﯾﺎ ﺍﺛﺮﺑﺨﺸﯽ ﺁﻥ ﺩﺳﺘﮕﺎﻩ ﯾﺎ ﺳﯿﺴﺘﻢ .ﺩﺳﺘﮕﺎﻩ ﻫﺎ ﯾﺎ ﺳﯿﺴﺘﻢ ﻫﺎﯼ ﺣﺎﻣﯽ ﺣﯿﺎﺕ ﺑﺮﺍﯼ ﮐﺎﺷﺖ ﺩﺭ ﺑﺪﻥ
ﺍﻧﺴﺎﻥﯾﺎ ﺣﻤﺎﯾﺖ ﻭ/ﯾﺎ ﺣﻔﻆ ﻭ ﻧﮕﻬﺪﺍﺭﯼ ﻭ/ﯾﺎ ﻣﺤﺎﻓﻈﺖ ﺍﺯ ﺯﻧﺪﮔﯽ ﺍﻧﺴﺎﻥ ﺩﺭ ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪﻩ ﺍﻧﺪ .ﺍﮔﺮ ﺁﻧﻬﺎ ﺷﮑﺴﺖ ﺑﺨﻮﺭﻧﺪ ،ﻣﻨﻄﻘﯽ ﺍﺳﺖ ﮐﻪ ﻓﺮﺽ
ﮐﻨﯿﻢﺳﻼﻣﺖ ﮐﺎﺭﺑﺮ ﯾﺎ ﺳﺎﯾﺮ ﺍﻓﺮﺍﺩ ﻣﻤﮑﻦ ﺍﺳﺖ ﺑﻪ ﺧﻄﺮ ﺑﯿﻔﺘﺪ.