No.:Version 1.

LS48V100Ah
Product Specification

EVPS Anhui Power Battery Co., Ltd


Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province, China

1
Menu

1 Overview.................................................................................................................................. 3
2 Important safety instructions ........................................................................................... 3
3 Technical Indicators............................................................................................................ 5
4 Battery Module Appearance and Assembly..................................................................6
5 Battery Pack Performance Inspection and Testing.....................................................8
6 Marking, packaging and transportation .......................................................................16
7 Storage and Others ............................................................................................................ 16

EVPS Anhui Power Battery Co., Ltd


2 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
1 Overview
Lithium-ion battery module is a battery pack composed of lithium-ion battery cells connected
in series and parallel, and does not contain protection and control circuits. In order to ensure
the safety and performance of the battery module, it should be used with the protection control
circuit.

2 Important safety instructions


 Ensure that the battery is kept away from hazardous items or hazardous materials, such as
corrosive chemicals, hazardous machinery and equipment, high temperature environment,
etc.
 Unreasonable use of this series of products may lead to smoke, such as external short
circuit, overcharging, too high ambient temperature, etc. In case of smoke emission, please
cut off the power supply in time, use carbon dioxide or dry powder fire extinguisher to deal
with it, and bury it with sand or soil. The whole process must be evacuated in time and the
police must be called in time (if necessary).
 It is prohibited to disassemble, crush, puncture, set aside or bake the battery at high
temperature to avoid the battery being subjected to excessive amplitude of vibration,
external impact, falling from a high place, etc. This operation may cause personal injury or
property damage.
 It is prohibited to directly short circuit positive and negative terminals of the battery to
avoid any metal or other conductive objects other than the battery post compression bolts
and conductive tape from touching the positive and negative terminals of the battery,
which may result in personal injury or property damage.
 Do not expose or leave the battery for prolonged periods of time at temperatures above
60°C. Do not attempt to heat or throw the battery into a fire, as this may result in personal
injury or property damage.
 It is prohibited to charge the battery without reasonable charging and discharging
protection devices (lithium-ion battery protection circuit boards, battery management
systems, etc.) or with charging equipment (chargers, DC power supplies, etc.) that are not
approved by the manufacturer, as this may result in personal injury or property damage.
 It is prohibited to use this series product in series or parallel with other models or types of
batteries, this operation may lead to personal injury or property damage; if necessary,

EVPS Anhui Power Battery Co., Ltd


3 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
please contact the relevant technical department of our company to obtain the correct
technical support.
 Non-professionals should not disassemble the battery without authorization, do not modify
the battery without authorization, charging and discharging should not exceed the
maximum current specified in the technical parameters, avoid charging in direct sunlight.

EVPS Anhui Power Battery Co., Ltd


4 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
3 Technical Indicators
No. Item Parameter Remark
Battery Module Nominal
3.1 48V100Ah 4800wh 2P15S
Voltage/Capacity/Energy

3.2 Battery Model LS48V100Ah

3.3 Cell Model ITPt123123310-500E

Control by
3.4 Charging Cut-off Voltage 3.65V individual
voltage
Control by
3.5 Discharging Cut-off Voltage 2.0V individual
voltage

3.6 Overall Voltage Range 30V~54.7V

3.7 Maximum Continuous Charging Current 50A

3.8 Maximum Continuous Discharging Current 100A

3.9 Battery Module External Dimensions 405*368*128mm

3.10 Battery Module Weight 35±1kg

3.11 Cycle Life 3000 cycles@80%DOD, 0.5C/0.5C

Same Group Capacity Difference:


0.5mA(1%), internal resistance
3.12 Cell Assembly difference:
0.4mΩ(ACR), voltage difference
4mV @30% SOC

Charging 0~45℃
3.13 Operating
Temperature Discharging -20~60℃

1 year -20℃~25℃
Storage
3.14
Temperature 3 months -20℃~45℃

EVPS Anhui Power Battery Co., Ltd


5 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
4 Battery Module Appearance and Assembly

4.1 Dimensional Drawings

4.2 Installation and Interface Definitions


As shown in the figure below, the module is fastened to the case with 8 M6x20 bolts and 2 strips
(only the prototype comes with strips and bolts).

The sampling harness has a total of 4 interfaces, the length of the harness out of the module is
450mm, and the interface is defined as follows:

EVPS Anhui Power Battery Co., Ltd


6 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
EVPS Anhui Power Battery Co., Ltd
7 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
5 Battery Pack Performance Inspection and Testing
The product test refers to the national standard GB/T36276-2018 "Lithium-ion Battery for Power
Storage". Terminology references in the text are in accordance with this standard.

5.1 Standard test conditions


5.1.1 Environmental Test Conditions

Unless otherwise specified, the environmental conditions for all tests are as follows:
Temperature: 25 ± 2 ℃ ; Relative Humidity: ≤ 90%; Atmospheric Pressure: 86-106 KPa. Room
temperature, as mentioned herein, refers to 25°C±2℃。
5.1.2 Measuring Instrument Requirements
Voltage measuring device: not less than 0.5 grade
Current measuring device: not less than 0.5 grade
Temperature measuring device:±0.5℃
Time measuring device:±0.1%
Dimension measuring device:±0.1%
Mass measuring device:±0.1%
5.1.3 Initial Charging

1) Set aside at (25±2)℃ for 5h;


2) Discharge the battery with constant power of Prd2 to the discharge termination voltage of
any single unit or battery module, and leave it for 30min;
3) Charge with constant power of Prd2 to the charging termination voltage of any single unit
or battery module, and leave it for 30min.
5.1.4 Initial Discharging

1) Set aside at (25±2)℃ for 5h;


2) Charge with constant power of Prd2 to the charging termination voltage of any single unit
or battery module and leave it for 30min.
3) Charge with constant power of Prd2 to the discharging termination voltage of any single
unit or battery module and leave it for 30min.

5.2 Performance

Test Methods and


No. Item Performance Standards
Environment
EVPS Anhui Power Battery Co., Ltd
8 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
 Initialize discharging of the battery
module;
 Charge with constant power of
Prd2 to the charging termination
 The initial charging
voltage of any single unit or
energy is not less
battery module, and leave it for
than the rated
30min.
charging energy;
 Discharge with constant power of
 Initial discharge
Prd2 to the discharge termination
energy is not less
voltage of any single unit or
than rated
battery module, and leave it for
discharge energy;
30min.
 Energy efficiency is
 Repeat step 2 and 3 two times, and
not less than 93%;
take the average value of the 3
 The mean value of
tests as the result.
the initial charging
 Record the initial charging energy,
energy extremes of
Initial charge and initial discharge energy, charging
5.2.1 the test samples is
discharge energy time, discharge time, the range of
not greater than 7%
initial charging energy of all test
of the mean value
samples, the range of initial
of the initial
discharge energy of all test
charging energy;
samples, the initial charging
 The mean value of
capacity, and the initial discharge
the initial
capacity of steps 2 and 3. Calculate
discharging energy
the percentage of mass energy
extremes of the
density, volume energy density,
test samples is not
energy efficiency, and average
greater than 7% of
range of initial charging energy in
the mean value of
the average initial charging energy
the initial
of all test samples, and the
discharging energy;
percentage of average range of
initial discharge energy in the
average initial discharge energy of
all test samples.
5.2.2 High  Initialize discharging of the battery  The charging
temperature module; energy is not less
charge/discharge  The battery module is set aside at than 98% of the

performance (45±2)°C for 5h; initial charging


 Charge to the charging termination energy;
voltage of any single unit or  The discharging
battery module at (45 ± 2) ° C with energy is not less
constant power of Prd2 and leave it than 98% of the
for 30min. initial discharging

EVPS Anhui Power Battery Co., Ltd


9 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
 Discharge the battery at (45 ± 2) ℃ energy;
with constant power of Prd2 to the  Energy efficiency is
discharge termination voltage of not less than 90%.
any single unit or battery module.
 Record the charging energy,
discharging energy, charging time,
discharging time, charging capacity
and discharging capacity of step 3
and 4. Calculate energy efficiency;
The energy retention rates of
charging energy and discharge
energy relative to initial charging
energy and initial discharge energy
were calculated.
5.2.3 Low Temperature  Initialize discharging of the battery  The charging
Discharge module; energy is not less
Performance  The battery module is set aside at than 80% of the
(5±2)°C for 5h; initial charging
 Charge to the charging termination energy;
voltage of any single unit or  The discharging
battery module at (5 ± 2) ° C with energy is not less
constant power of Prd2 and leave it than 75% of the
for 30min. initial discharging
 Discharge the battery at (5 ± 2) ℃ energy;;
with constant power of Prd2 to the  Energy efficiency is
discharge termination voltage of not less than 75%.
any single unit or battery module.
 Record the charging energy,
discharging energy, charging time,
discharging time, charging capacity
and discharging capacity of step 3
and 4. Calculate energy efficiency;
The energy retention rates of
charging energy and discharge
energy relative to initial charging
energy and initial discharge energy
were calculated.
5.2.4 Normal  Initialize charging of the battery  The energy
temperature module; retention rate is
charge retention  The battery module is set aside at not less than 90%;

and recovery (25±2)°C for 28d;  Charging energy

capability  Discharge to the discharging recovery rate is not


termination voltage of any single less than 92%;

EVPS Anhui Power Battery Co., Ltd


10 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
unit or battery module at (25±2)°C  Discharge energy
with constant power of Prd2 and recovery rate is not
leave it for 30min. less than 92%.
 Charge to the charging termination
voltage of any single unit or
battery module at (25 ± 2) ° C with
constant power of Prd2 and leave it
for 30min.
 Discharge the battery at (25 ± 2) ℃
with constant power of Prd2 to the
discharge termination voltage of
any single unit or battery module.
 Record the charging energy,
discharging energy, charging time,
discharging time, charging capacity
and discharging capacity of step 3
and 4. Calculate energy efficiency;
The energy retention rates of
charging energy and discharge
energy relative to initial charging
energy and initial discharge energy
were calculated.
5.2.5 High  Initialize charging of the battery  The energy
temperature module; retention rate is
charge retention  The battery module is set aside at not less than 90%;

and recovery (45±2)°C for 7d;  Charging energy

capability  The battery module is set aside at recovery rate is not


(25±2)°C for 5h; less than 92%;
 Discharge to the discharging  Discharge energy
termination voltage of any single recovery rate is not
unit or battery module at (25±2)°C less than 92%.
with constant power of Prd2 and
leave it for 30min.
 Charge to the charging termination
voltage of any single unit or
battery module at (25 ± 2) ° C with
constant power of Prd2 and leave it
for 30min.
 Discharge the battery at (25 ± 2) ℃
with constant power of Prd2 to the
discharge termination voltage of
any single unit or battery module.
 Record the holding energy of step

EVPS Anhui Power Battery Co., Ltd


11 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
4 and the charge recovery energy
and discharge recovery energy of
step 5 and 6. The energy retention
rate of the holding energy relative
to the initial discharge energy is
calculated. The energy recovery
rates of charge recovery energy
and discharge recovery energy
relative to initial charge energy
and initial discharge energy were
calculated.
5.2.6 Storage  Initialize charging of the battery  The recovery rate
Performance module; of charging energy
 Discharge at constant power with is not less than
Prd2 until the discharged energy 90%;
reaches 50% of the initial  Discharge energy
discharged energy of the battery recovery rate is not
module at (25±2)°C,; less than 90%.
 The battery module is set aside at
(45±2)°C for 7d;
 The battery module is set aside at
(25±2)°C for 5h;
 Discharge to the discharging
termination voltage of any single
unit or battery module at (25±2)°C
with constant power of Prd2 and
leave it for 30min.
 6) Charge to the charging
termination voltage of any single
unit or battery module at (25±2)°C
with constant power of Prd2 and
leave it for 30min.
 Discharge at constant power of
Prd2 to the discharge termination
voltage of any single cell or battery
module at (25±2)°C;
 Record the charge recovery energy
and discharge recovery energy of
step 6 and 7. The energy recovery
rates of charge recovery energy
and discharge recovery energy
relative to initial charge energy
and initial discharge energy were

EVPS Anhui Power Battery Co., Ltd


12 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
calculated.
5.2.7 Insulation  Initialize charging of the battery Calculated according to
Performance module; the nominal voltage, the
 Disconnect the positive and insulation resistance
negative terminals of the battery between the positive
module from the external device; terminal of the battery
 Use insulation tester DC500V stop, module and the
were applied to the positive
external exposed
terminal, negative terminal and
conductive part, and the
external bare conductive parts
insulation resistance
between;
between the negative
terminal of the battery
module and the
external exposed
conductive part shall
not be less than 1000 Ω
/V.
5.2.8 proof voltage  Initialize charging of the battery When a voltage of
performace module. AC1000V or DC1415V is
 The voltage applied at the applied between the
beginning of the test shall not be positive terminal of the
more than 50% of the specified battery module and the
value, and then the test voltage exposed conductive part
shall be smoothly increased to the
of the external battery,
specified maximum value within a
or between the negative
few seconds and maintained for 5s;
terminal of the battery
 The test voltage shall be applied
module and the
between the positive terminal of
exposed conductive part
the battery module and the
of the external battery,
exposed conductive part of the
breakdown or flashover
external support and between the
negative terminal of the battery shall not occur.

module and the exposed


conductive part of the external
conductive part;
 AC voltage or DC voltage equal to
the peak value of the specified AC
voltage can be used for the test, AC
or DC test voltage RMS value
should not be greater than 5% of
the specified value;
 AC power supply should have

EVPS Anhui Power Battery Co., Ltd


13 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
enough power to maintain the test
voltage, without regard to leakage
current, this test voltage should be
sinusoidal, and the frequency of
45Hz ~ 62Hz;
 Record whether there is
breakdown or flashover
phenomenon.
5.2.9 Cycle  Initialize discharging of the battery  When the number
performance module. of cycles reaches
 Charge with constant power of 500 times, the
Prd2 to the charging termination charging energy
voltage of any single unit or retention rate is
battery module and leave it for not less than 90%;
30min.  When the number
 Discharge with constant power of of cycles reaches
Prd2 to the discharge termination 500 times, the
voltage of any single unit or discharge energy
battery module, and leave it for retention rate is
30min. not less than 90%;
 Cycle 500 times continuously
according to 2)~3);
 Discipline the charging energy of
step 2 and 3 for the first time and
20 times per cycle, Discharge
energy, charge time, discharge
time, end of charge and discharge
 The voltage difference between the
battery cells at the end of charging
and discharging; calculate the
voltage difference between the
charging energy and discharging
energy at the end of each 20
cycles. Calculate the energy
difference between the charging
energy and discharging energy at
the end of every 20 cycles relative
to the charging energy and
discharging energy at the end of
the first cycle. Calculate the energy
retention rate of the charging
energy and discharging energy at
the end of every 20 cycles relative

EVPS Anhui Power Battery Co., Ltd


14 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
to the charging energy and
discharging energy at the end of
the first cycle and the
corresponding energy efficiency;
Calculate the average value of
voltage difference of each battery
at the end of the cycle test; make
the charging energy retention rate
according to the test data.
According to the test data, make
the curves of charging energy
retention rate, discharging energy
retention rate and energy
efficiency change with the number
of cycles. Calculate the average of
the voltage difference of a single
cell at the end of the cycle test;
and make a graph of the change of
charging energy retention rate,
discharging energy retention rate
and energy efficiency according to
the test data.
5.2.10 Over-charging  Initialize charging of the battery No fire, no explosion.
module;
 The battery module is charged in
1Crd2 constant current mode until
the voltage of any battery cell
reaches 1.5 times of the battery cell
charging termination voltage or the
time reaches 1h;
 Observe for 1h.
5.2.11 Over-discharging  Initialize charging of the battery No fire, no explosion.
module;
 The battery module should be
discharged in 1Crd2 constant
current mode until the time
reaches 90min or the voltage of
any battery unit reaches 0V, and
should not catch fire or explode.

EVPS Anhui Power Battery Co., Ltd


15 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China
6 Marking, packaging and transportation
6.1 Marking
Signs may be executed as required by the contract between the parties.

6.2 Packaging
The products are packed in cardboard boxes with product certificates, packing lists, and product
description information.

6.3 Transportation
Packing boxes containing products should be loaded, unloaded and transported in accordance
with GB/T191. It should be handled gently and should not be thrown. During transportation, it
should be prevented from violent vibration, impact or extrusion, and should not be exposed to
sunshine or rain, and it is strictly prohibited to be mixed with flammable goods and active
chemicals.

7 Storage and Others


7.1 Storage
The products should be stored in a clean, dry, ventilated, rainproof and snow-proof room, and
should not be stored with acid, alkali and other corrosive substances or dusty items. It should
not be exposed to direct sunlight, and should not be less than 2m away from fire source and
heat source (heating equipment, etc.) The box with the products should be properly padded
and ≥100mm from the ground, and the stacking height should not be more than 1.5m.

7.2 Others
Any matter not referred to in this Prospectus shall be subject to negotiation between the
parties.

EVPS Anhui Power Battery Co., Ltd


16 Intersection of Huangqinghu Road and Yuanshan Road, Nanqiao District,
Chuzhou City, Anhui Province,China

You might also like