APPLICATION GUIDE

VDC
M +24
CO
E M
E SID CH
4
CO
G
LTA CH 2 CH
3
V O
L O W CH
1
ORS
SEN
TO
2

P H O
EPC

E
BLU
M
CO
E
BLU MON
O M
C
E
BLU MON NG
E
M
CO ORA NO
E
NG NO
E
BLU MON ORA
M
CO
NO NG
E
NGE ORA NO
ORA

-24
A 2 00RRIDE) S
SS OVE 3
R
(CH

4 RED
0R 2

NOVEMBER 2008

A DIVISION OF NSi INDUSTRIES, LLC


Table of
APPLICATION
Contents ACCESSORIES PAGE
REQUIRED
TRANSFORMER RELAY POWERPACK (TRP-D) 1

DIGITAL TIME CONTROLS


Control low voltage lighting using transformer relay powerpacks TRP-D 2
Switch loads higher than the time switch contacts TRP-D 3
Switch 2 loads at same time using low voltage wire TRP-D 3
Switch two 120V circuits using 240V lines with neutral TRP-D 4
Switch 208-240V loads up to 40 amps 4
Switching higher voltage and/or amperage Contactor 5
Single channel controls 2 circuits alternately Contactors 6
Remote station timed or manual override of lighting Contactor + Interval Timer 6
Maintained contact time switch for momentary contact system SMC3D + Contactor 7
4 zone lighting controller with photo sensor input and remote override inputs 8
Time switch with input from photo sensor or other dry contact closure Photocontrol/Maintained Switch 9
Combination time + light level control with contactors Contactors 10
Control 2 lighting zones with different light level setpoints 10
Time switch with input from photo sensor or other dry contact closure (2 circuits) Contactors 11
Combination time + light level control of momentary system Photocontrol + SMC3D 12
Day/Night, Winter/Summer thermostat controls Thermostat 12
Momentary contact time switch for GE type low voltage latching relays Transformer + Relay 13
Pulsed time switch for low voltage signaling devices Transformer 13
Timed override ON with warning blink or auxilary external signal before OFF LDS/LDSH 14
Multi-channel dry contact time switch for higher load switching using TRP-D TRP-D 15
Multi-channel dry contact time switch for higher load switching using 5401/5441 Contactor 16

ELECTROMECHANICAL TIME SWITCHES


Dim lighting at selected times TRP-D 17
Switching momentary contact system SMC3D 17
Combination time and light level control of momentary system Photocontrol + SMC3D 18

PHOTOCONTROL / TIME SWITCH


Switching higher lighting loads TRP-D 18

INTERVAL TIMERS AND OCCUPANCY SENSORS


Timed operation of momentary contact system SMC3D 19
Increased area coverage with multiple sensors TRP-D 19
Switching multiple circuits with one sensor TRP-D 20
Control low voltage lighting system TRP-D + SMC3D 21
Time switch controls when sensor functions TRP-D + Time Switch 22
Wall sensor or electronic interval timer switches higher loads TRP-D 22
Wall sensor or electronic interval timer for 3 way switching 23

3 WAY WALL SWITCHES


Inexpensive method for low voltage wiring TRP-D 23

ACCESSORY ENCLOSURE DIMENSIONS


TRANSFORMER RELAY POWERPACKS APPLICATIONS GUIDE
APPLICATIONS
• Low voltage switching of line voltage lighting circuits.
• Low voltage switching by digital or mechanical controls for higher amperage loads
including those of two different voltages.

DESCRIPTION
Self contained transformer and relay with SPST dry contacts rated at 20 AMP 120VAC, or
277VAC. Internal power source provides for low voltage control of line voltage contacts, thus
eliminating the need for a separate step down transformer.
For multi-channel digital controls, TORK offers output panels, available in groups of 4 or 8

SPECIFICATIONS
Contacts: SPST Dry Contacts
Contact Rating: 20 Amps Ballast
20 Amps Incandescent (at 120VAC)
20 Amps General Purpose
1.0 Horsepower @ 120VAC
Temperature Range: 0° to 150°F (-18° to 66°C)

Input Voltage Group of 4 Group of 8


120 VAC TRP 400 TRP 800
277 VAC TRP 402 TRP 802

LOW VOLTAGE 2
CONDUCTOR 22GA
CLASS 2 WIRING N
INPUT VOLTAGE
L

MAINTAINED CONTACT
FROM MANUAL OR TRP
TIME SWITCH N
(DRY CONTACT) L
N
INPUT VOLTAGE
L

TRP

L
N

NOVEMBER 2008 1
A DIVISION OF NSi INDUSTRIES, LLC
LOW VOLTAGE CONTROL OF LIGHTING USING
TRANSFORMER RELAY POWERPACKS
TORK TIME SWITCH
(DRY CONTACT)

IF THREE-WAY SWITCHING IS REQUIRED


(ELIMINATE STANDARD WALL SWITCH)

BLACK
BLUE

RED
NEUTRAL WHITE
BLACK
LINE
RED TRP-D
RED

LIGHT LIGHT LIGHT


FIXTURE FIXTURE FIXTURE

BLACK
BLUE

RED

NEUTRAL WHITE
BLACK
LINE
RED TRP-D
RED
LOW VOLTAGE WIRING
MINIMUM 22 AWG
MAXIMUM LENGTH OF 500FT

LIGHT LIGHT LIGHT


FIXTURE FIXTURE FIXTURE

Low voltage wiring: If three-way switching is required Standard wall switch or any digi-
Minimum 22AWG (eliminate standard wall switch) tal time switch
Maximum length of 500ft
TRP-D 120 / 277 Vac =
20amps ballast
20amps incandescent

ContactsNote: ALL SWITCHES SHOWN ARE MAINTAINED – NO MOMENTARY SWITCHES

2
APPLICATIONS GUIDE
SWITCHING LOADS HIGHER THAN THE
TIME SWITCH CONTACTS: SINGLE CIRCUIT CONTROL
For control by TORK digital time switches or lower
amperage mechanical time switches where switching
of higher load capacity is necessary. For example, 1.0
HP exhaust fan is switched by a TORK controller using
simple low voltage wire. TRP may be installed remote TORK DIGITAL CONTROL
from digital controller up to 500’ with #22 AWG low TERMINAL BLOCK
voltage wire. NO C NC

not used
BLACK
WHITE

BLUE

RED
NEUTRAL
BLACK
LINE RED TRP-D
RED

LOAD

1.0 HP MOTOR

MULTI CIRCUITS: SINGLE


CHANNEL CONTROL
For control of 2 different loads at the same time using low voltage
wire with a single channel TORK controller. Use 2 TRP-D’s which are
connected in parallel. For example, exhaust fan and lighting load
(each are 120V). Up to 5 TRP-D’s can be used on one channel. TRP
may be installed remote from digital controller up to 500’ with #22 TORK TIME SWITCH
AWG low voltage wire. TERMINAL BLOCK
NO C NC
not used
BLACK
BLUE

RED

WHITE
NEUTRAL
BLACK
LINE RED TRP-D
RED

LOAD

1.0 HP MOTOR
not used
BLACK
BLUE

WHITE
RED

NEUTRAL
BLACK
LINE
RED TRP-D
RED

3
3
NOVEMBER 2008 A DIVISION OF NSi INDUSTRIES, LLC
TYPICAL WIRING WITH TORK DIGITAL CONTROL
SWITCHING 208-240 VOLTS
WITH NEUTRAL: USING 2 TRP-D’S
To control 2 separate 120V circuits using 240V 3
wire lines. TORK digital controller is wired to 2
TRP-D’s using low voltage switching. TRP-D’s may be TORK DIGITAL CONTROL
installed remote from digital controller up to 500’ with TERMINAL BLOCK
#22 AWG low voltage wire.
NO C NC

not used
BLACK
BLUE

RED
WHITE
N
BLACK
L1 RED TRP-D
RED
L2

LOAD

not used
BLACK
BLUE
WHITE

RED
BLACK
RED TRP-D
RED

LOAD

SWITCHING 208-240 VOLTS


WITHOUT NEUTRAL: E103B, EW103B AND EWZ103
For control of loads rated 208-240 VAC up to 40
Amps resistive/inductive. TORK TIME SWITCH
TERMINAL BLOCK

3 4 5 6
L1
208 OR 240VAC
L2

LOAD

4
APPLICATIONS GUIDE
SWITCHING HIGHER VOLTAGE AND/OR
AMPERAGE USING CONTACTORS
To control 120 volt circuits where increased voltage TYPICAL WIRING WITH TORK CONTACTORS
and/or amperage switching is necessary, close to or 5401, 5440 AND OTHER CONTROL SYSTEMS
remote from controller. Can switch up to 40 amps per
pole from 120VAC to 480 VAC, one or two circuits TORK DIGITAL CONTROL
simultaneously. Indoor-outdoor enclosure. TERMINAL BLOCK
NO C NC
MECHANICALLY HELD CONTACTOR
SELF CLEARING
OPEN
LINE
CLOSE
120VAC

NEUTRAL C

ELECTRICALLY HELD CONTACTOR


LOAD 40A MAX PER POLE

120VAC COIL

TORK MODELS 5401 & 5441


OR SUITABLE SUBSTITUTES
LINE 120/240/277/480VAC

TORK’s model 5441 contains 4-3PST contactors - 40 TYPICAL WIRING WITH TORK MODEL 5441
Amp contacts - 8VA coil power per contactor - 120 MULTIPLE ELECTRICALLY-HELD CONTACTORS
VAC. Electrically-held in one enclosure (indoor only).
Wire close to or remote from controller. Up to 4
contactors may be parallel wired to 1 circuit; time TORK TIME SWITCH
controlled, indoor lighting, motor loads, ventilating TERMINAL BLOCK
systems, refrigeration ambient defrosting. NO C NC NO C NC

LINE LOAD 40A MAX PER POLE

120VAC 120VAC COIL


CIRCUIT 1

TORK MODEL 5441 CONTACTOR

NEUTRAL

LINE 120/240/277/480VAC
LOAD 40A MAX PER POLE
CIRCUIT 2

120VAC COIL

LINE 120/240/277/480VAC

NOVEMBER 2008 5
A DIVISION OF NSi INDUSTRIES, LLC
SINGLE CHANNEL
CONTROLLING TORK DIGITAL CONTROL TORK DIGITAL CONTROL
TWO DIFFERENT CIRCUIT #1 CIRCUIT #1

CIRCUITS ALTERNATELY NO C NC NO C NC

LOAD TO Security
Combination day-time control of lighting/night- & Alarm System
time control of security system. LINE FROM Security
LINE & Alarm System
Use NC of circuit 2 to turn “ON” security sys- 120VAC
tem when circuit 1 turns “OFF”. TORK MODEL 5401 CONTACTOR
NEUTRAL 3PST
Lighting Load

120VAC COIL

LINE 120/240/277/480VAC
LOAD 40A MAX PER POLE

REMOTE STATION TIMED OVERRIDE OF LIGHTING


CIRCUITS USING INTERVAL TIMER
For remote station timed override of lighting
circuits where the TORK Digital Time Switch
does not offer this feature. Two Model 5401 TORK DIGITAL CONTROL
electrically-held lighting contactors are utilized. TERMINAL BLOCK
NO C NC NO C NC
TORK “A500 Series” spring wound interval
timers can provide timed overrides of up to 12 LINE
hours. For remote manual override in addition
LOAD 40A MAX PER POLE
to timed override, use models with HOLD fea-
ture for constant ON. 120VAC

Tork SSA100/SSA200 electronic interval timer

CIRCUIT 1
can provide remote timed override of up to 12
NEUTRAL
hours. A flicker/beep warning can be selected
prior to turn-off.
120VAC
COIL

LINE 120/240/277/480VAC
TORK TORK MODEL 5401 CONTACTOR
A500 SERIES 3PST
INTERVAL
TIMER
LOAD 40A MAX PER POLE

OR
TORK SSA 100/200 SERIES
CIRCUIT 2

ELECTRONIC INTERVAL TIMER

BLACK
120VAC
RED COIL

LINE 120/240/277/480VAC
GREEN TORK MODEL 5401 CONTACTOR
3PST

6
APPLICATIONS GUIDE
CONVERT MAINTAINED TO
MOMENTARY CONTACT
TORK DIGITAL CONTROL
The SMC-3D will operate low voltage TERMINAL BLOCK
latching relays or mechanically held (MAINTAINED CONTACT INPUT)
contactors with or without remote manual SMC-3D NO C NC
push button override. INPUT: SUSTAINED VOLTAGE 120VAC H
MOMENTARY CONTACTS (UNPOWERED) N
120VAC
The adapter converts a constant applied 30A INRUSH:
120VAC, 240VAC
120VAC (input) to a 2 second con-
277VAC, 30VDC SMC-3D 120VAC
tact closure at the “ON RELAY” output
closing common and normally open ON RELAY OFF RELAY
NC NO C NC NO C
(C, NO). When the constant applied
120VAC input opens, a 2 second con-
tact closure at the “OFF RELAY” output ON PULSE PUSH
between common and normally open (C, LOW VOLTAGE ON
LATCHING RELAY
NO) occurs. The SMC-3D can be oper- OR MECHANICALLY OFF PULSE
ated by any TORK time controller or a HELD CONTACTOR PUSH
H OFF
remote manual SPST standard constant NEUTRAL
120VAC
N
“ON-OFF” switch.
TORK DIGITAL CONTROL
ELECTRICALLY HELD CONTACTOR OR MOTOR STARTER TERMINAL BLOCK
The SMC-3D with pulse “ON” an electri- L L L (MAINTAINED CONTACT INPUT)
cally held contactor or motor starter with NO C NC
self contained “ON-OFF” push buttons.
H
“ON” relay will pulse 2 second “ON” 120VAC
120VAC COIL N
and electrically hold the contactor “ON”.
By interrupting the holding circuit of the AUX
contactors “OFF” button across com-
SMC-3D 120VAC
CONTACTS
mon and normally closed (C, NC) of the ON RELAY OFF RELAY
SMC-3D “OFF” relay the 2 second open- NC NO C NC NO C
ing of common and normally closed (C, REMOTE SWITCHES OPTIONAL
NC) will allow the electrically held con- LOAD LOAD LOAD
N
PUSH
tactors to open, thereby going “OFF”. ON
N N N
PUSH
OFF

NOVEMBER 2008 7
A DIVISION OF NSi INDUSTRIES, LLC
4 ZONE LIGHTING CONTROLLER WITH PHOTO SENSOR INPUT
AND DRY CONTACT REMOTE OVERRIDE INPUTS
The DLC400BP is a multi-voltage, dedicated 4 zone
lighting controller with photocell input in a NEMA
3 Enclosure. The unit has 30 AMP SPDT heavy duty
contacts, therefore eliminating the need for costly
contactors in most application. Each zone can be
actuated by 1) The photosensor, or 2) Time of day,
or 3) A combination of both. Light level setting at
which lights turn on and off as well as time sched-
ules are assigned independently to each zone, with
the additional capability of remote override inputs
from external switches or local override at the key-
pad.

1. Photo sensor input for all 4 zones each zone


can be controlled through:
A. Time of Day ON/Time of Day OFF
B. Light Level ON/Time of Day OFF
C. Light Level ON/Light Level OFF
2. Remote Input override for all 4 zones
A. Each zone can accept a dry contact closure
for remote override.
B. For timed remote override, use SSA 100/200
Series or A500/C500 Series.
3. Low Voltage (24VDC) supply by the unit to
power low voltage circuits such as occupancy
sensors.

8
APPLICATIONS GUIDE

UNIVERSAL INPUT
FROM PHOTOCELL TORK MODEL DGUM 100 TORK MODEL DGU 100
TERMINAL BLOCK TERMINAL BLOCK
CLOCK (MOMENTARY CONTACTS) CLOCK (MOMENTARY CONTACTS)
INPUT DRY CONTACTS (UNPOWERED) INPUT DRY CONTACTS (UNPOWERED)
H N NO C NC NO C NC H N NO C NC SELF CLEARING
MECHANICALLY HELD CONTACTOR
OPEN
ON OFF H
CLOSE
N C
Single channel time switch accepts
remote input from any dry maintained
contact closure and photocell or ther- TORK EPC1
mostat. Use to control outdoor lighting

OR MAINTAINED SWITCH
USE EITHER PHOTOCELL
(BUT NOT BOTH!)
or HVAC. PHOTO
CONTROL
REMOTE INPUT REMOTE INPUT
1 2 3 1 2 3

WHITE REMOTE INPUT


FROM MAINTAINED
PHOTOCELL MAINTAINED SWITCH SWITCH
WHITE

NOVEMBER 2008 9
A DIVISION OF NSi INDUSTRIES, LLC
COMBINATION PHOTOCONTROL/TIMED ON-OFF SWITCHING
OF GREATER LOAD CAPACITIES
To control lighting circuits where a
Photocontrol turns “ON” at dusk (controller TORK
PHOTOELECTRIC
should be set for “ON” before dusk) and
CONTROL TORK DIGITAL CONTROL
“OFF” by preset times of 120VAC control- TERMINAL BLOCK
ler. Controller can be set to turn “ON” early
NO C NC
a.m. before dawn, and have Photocontrol PHOTO
turn “OFF” at dawn…turn back “ON” at CONTROL
dusk, and controller turns lights “OFF” during TORK MODEL 5401 CONTACTOR
nights when lighting is no longer needed. TORK MODELS
LOAD 40A MAX PER POLE
2000 / 2001 / 2021
Photocontrol can be wired direct to 120VAC 2101 / 3000
control circuits.

WHITE
BLACK
RED
NEUTRAL 120VAC COIL

120VAC
LINE

LINE 120/240/277/480VAC

LIGHTING CONTROLLER
INDEPENDENT LIGHT LEVEL/TIME-OF-DAY OPERATION OF TWO
LIGHTING ZONES (I.E. 2 LEVEL ATRIUM LIGHTING)
The LC200 consists of an electronic control
and an electronic light sensor interacting. The
unit offers separate control of two lighting
zones, each with user settable on/off light
level setpoints. The Electronic control also
offers two digital inputs which will accept
a contact closure from any Tork Timer(s), or
existing EMS system to provide for indepen-
dent Time-Of-Day override.

10
APPLICATIONS GUIDE
DIGITAL LIGHTING CONTROLLER
MODEL DGLC
1. For wiring to electrically-held contactor - see Fig. 1
2. For coil clearing mechanically-held contactor - see Fig. 2
3. Fig. 1 and Fig. 2 - one circuit can be used to control electronically-held contactor while the other circuit controls
a mechanically-held contactor.

FIG. 1

TORK MODEL DGLC


TERMINAL BLOCK TORK
CLOCK (MAINTAINED CONTACTS)
INPUT DRY CONTACTS (UNPOWERED) EPC1
(DEDICATED) CIRCUIT 1 CIRCUIT 2
REMOTE INPUT
H N NO C NC NO C NC 1 2

WHITE
WHITE

LINE
TORK MODEL 5401 CONTACTOR
120VAC (DEDICATED) (OR OTHER ELECTRICALLY HELD CONTACTOR)
NEUTRAL LINE 120/240/277/480VAC

120VAC
COIL
LINE
120VAC
LOAD 40A MAX PER POLE
NEUTRAL
LINE 120/240/277/480VAC

120VAC
COIL

LOAD 40A MAX PER POLE


FIG. 2
TORK MODEL DGLC
TERMINAL BLOCK TORK
CLOCK (MAINTAINED CONTACTS) EPC1
INPUT DRY CONTACTS (UNPOWERED)
(DEDICATED) CIRCUIT 1 CIRCUIT 2
REMOTE INPUT
H N NO C NC NO C NC 1 2

WHITE
LINE WHITE
120VAC (DEDICATED)
NEUTRAL SELF CLEARING
MECHANICALLY HELD CONTACTOR

OPEN

CLOSE
LINE
120VAC C
NEUTRAL
SELF CLEARING
MECHANICALLY HELD CONTACTOR

CIRCUIT 1 of Figure 1 and Figure 2 provides OPEN


(Photo ON/Time OFF) or (Photo ON/Time OFF/ CLOSE
Time ON/Photo OFF) operation.
C
CIRCUIT 2 of Figure 1 and Figure 2 provides
(Photo ON/Photo OFF) operation.
MODEL DGLC - 120 V
MODEL DGLC-3 - 277V
NOVEMBER 2008 11
A DIVISION OF NSi INDUSTRIES, LLC
DIGITAL TIME SWITCH
& PHOTOCONTROL
OPERATING WITH TORK DIGITAL CONTROL
PHOTO
MOMENTARY CONTACT SYSTEM TERMINAL BLOCK CONTROL
(MAINTAINED CONTACT INPUT)
TORK Model 2000, 2001 or 2101 photocontrol is NO C NC
wired in series with a digital time switch for photocon-
trol ON/timed OFF in connection with an SMC-3D
RED BLACK

WHITE
momentary contact adapter. For operation of mechan-
H
ically-held contactors and low voltage relays where
120VAC
remote momentary push button stations are necessary N
or already exist.
SMC-3D
120VAC
MOMENTARY CONTACTS
ADAPTER SMC-3D ON RELAY
NC NO C
OFF RELAY
NC NO C

ON PULSE PUSH
LOW VOLTAGE ON
LATCHING RELAY
OR MECHANICALLY OFF PULSE
HELD CONTACTOR PUSH
H OFF
120VAC
NEUTRAL N

TIME SWITCH CONTROLLING DAY/NIGHT THERMOSTATS


(SET-BACK/SET-UP)
A typical wiring diagram using a digital control
for night set-back for heating or night set-up for TORK DIGITAL CONTROL
TERMINAL BLOCK
cooling.
NO C NC
Winter Set-back: Set 2-wire night thermostat at
55°F. When control is “OFF” temperature will not
go below 55°.
24 VOLTS 24 VOLTS
LOW VOLTAGE TWO-WIRE NIGHT
When control is “ON” (day hours) day thermostat
CONTROL POWER THERMOSTAT
set at 70° to 72° will override night thermostat. (TIME SWITCH
FROM HVAC UNIT
CIRCUIT OFF)
Summer set-up: Night thermostat is usually set
at 90° to 95°. When control turns “ON”, day POWER
thermostat will override night setting and cool to
(76° to 78°) day setting. HEAT WHITE
RED
COOL YELLOW
DAY THERMOSTAT
FOUR WIRE HEAT/COOL THERMOSTAT
FAN GREEN (TIME SWITCH CIRCUIT ON)

12
APPLICATIONS GUIDE

MOMENTARY CONTACT TIME SWITCH FOR LOW VOLTAGE


LIGHTING CONTROL
To operate GE type low voltage control of lighting,
ventilating, etc. where low voltage relays must be
pulsed. Switch low voltage AC or DC. DGM100 or MOMENTARY CONTACTS
DGUM100 has unpowered contacts. TERMINAL BLOCK TORK MODEL
TORK MODELS DGM100, DGUM100 DZM200BP
NO C NC NO C NC
OR C ON OFF
120/208/240 VAC

LINE
BLACK
RED RELAY GE RR-7
OR EQUIVALENT
NEUTRAL BLUE
OPTIONAL HALF-WAVE
RECTIFIER - 24VAC
TORK MODEL TA 1245Y-75
(75VA TRANSFORMER)

DIGITAL CONTROL FOR SIGNALING DEVICES


For control of low voltage horns, bells, or lights.
Varied schedules are possible on different days + 2
different user selectable signal durations.

For line voltage signaling devices, omit transformer.


TORK DIGITAL CONTROL
TERMINAL BLOCK
For 2 channel signaling, use Model DTS200B. DGS SERIES

LINE
120VAC
NEUTRAL

TORKALERT™
TORK MODEL TA599 24 VAC HORNS
TRANSFORMER (40VA) TA874-G5, TA876-G5

NOVEMBER 2008 13
A DIVISION OF NSi INDUSTRIES, LLC
TIMED OVERRIDE “ON” FOR LIGHTING, HVAC
WITH WARNING OFF INDICATION
COVERS FROM 120 THRU 277 VAC
The LDS / LDS-A is an accessory to any TORK main- The LDSH / LDSH-A is an accessory to any TORK
tained contact time switch and is used to extend the maintained contact time switch and is used to extend
lighting time after the main time switch turns OFF a the time on of lighting, HVAC, and other main build-
lighting circuit. An approximate _ second blink will ing loads after the time switch turns OFF. An auxiliary
occur as a warning that the lighting will go OFF in (user contact closes, turning on a user selected signal device
selectable) 1 or 5 minute warning period. (i.e. bell, horn, light, or other warning device), which
turns off along with the main load at the end of the user
Remote momentary ON/OFF push button switches can selected 1 or 5 minute warning period.
be connected to the designated terminal of the Lighting
Delay Switch using low voltage # 18 - 22 AWG twisted Remote momentary ON/OFF push button switches can
pair wires. Pressing the remote ON button momentarily be connected to the designated terminal of the Lighting
during the 1 or 5 minute warning period (before the Delay Switch using low voltage # 18 - 22 AWG twisted
lights go out) will extend the time ON for a user select- pair wires. Pressing the remote ON button momentarily
able _ hour, I hour, 1-1/2 hour, 2 hours, 6 hours, 9 during the 1 or 5 minute warning period will extend
hours, or 12 hours. At the end of the extended time a the time on (main load) for a user selectable 1/2 hour,
warning blink will again occur, allowing personnel to 1 hour, 1 1/2 hour, 2 hours, 6 hours, 9 hours or 12
repeat another 12 hour extension if necessary. Pressing hours. At the end of the extended time, the user selected
the remote OFF button for 3 to 4 seconds will terminate signal device will turn on again, allowing personnel
the extension of time, and initiate the warning blink. to repeat another 1/2 hour – 12 hour extension of the
The lights will turn OFF after the 1 or 5 minute warning main load. Pressing the remote off button for 3 to 4
period. seconds will terminate the extension of time for the main
load and warning circuit. The main load and warn-
ing circuit will turn off after the 1 or 5 minute warning
period.

TORK TIME SWITCH


TORK TIME SWITCH TERMINAL BLOCK
TERMINAL BLOCK MOMENTARY NO C NC
MOMENTARY NO C NC OFF
OFF
MOMENTARY
MOMENTARY ON
ON

REMOTE C ON OFF H N N 120 208 277


REMOTE C ON OFF H N N 120 208 277 INPUT DO NOT APPLY TIME SWITCH 240 VAC
INPUT DO NOT APPLY TIME SWITCH 240 VAC VOLTAGE INPUT INPUT POWER
VOLTAGE INPUT INPUT POWER
AUX OUTPUT MAIN LOAD OUTPUT
MAIN LOAD OUTPUT TERMINALS TERMINALS
TERMINALS NC NO C NC NO C
NC NO C FIG. 1
FIG. 1
H
H
N
N
TORK TIME SWITCH
TORK TIME SWITCH TERMINAL BLOCK
TERMINAL BLOCK MOMENTARY NO C NC
MOMENTARY NO C NC OFF
OFF H
H MOMENTARY
MOMENTARY ON N
ON N

REMOTE C ON OFF H N N 120 208 277


REMOTE C ON OFF H N N 120 208 277 DO NOT APPLY TIME SWITCH 240 VAC
DO NOT APPLY TIME SWITCH 240 VAC INPUT VOLTAGE INPUT INPUT POWER
INPUT VOLTAGE INPUT INPUT POWER
AUX OUTPUT MAIN LOAD OUTPUT
MAIN LOAD OUTPUT TERMINALS TERMINALS
TERMINALS NC NO C NC NO C
NC NO C FIG. 2
FIG. 2
H
H
MECHANICALLY HELD ON
CONTACTOR WITH COIL ON
OFF
CLEARING CONTACTS OFF
N COMMON
N COMMON
MECHANICALLY HELD
CONTACTOR WITH COIL
CLEARING CONTACTS

14
APPLICATIONS GUIDE

TYPICAL WIRING WITH TRANSFORMER RELAY


POWERPACK (TRP-D)
FOR SWITCHING OF GREATER LOADS
DRY CONTACT OUTPUT

TORK DIGITAL CONTROL


TERMINAL BLOCK
CH 1 CH 2 CH 3 CH 4
SPDT SPDT SPDT SPDT

C NO NC C NO NC C NO NC C NO NC
not used
BLACK

N WHITE
BLACK
L
DRY CONTACTS RED
TRP-D BLUE
TO LOAD RED
RED not used
BLACK

N WHITE
BLACK
L
DRY CONTACTS
TRP-D BLUE
RED
TO LOAD RED
RED

not used
BLACK

N WHITE
BLACK
L
TRP-D BLUE
DRY CONTACTS RED RED
TO LOAD RED

not used
BLACK
TRP-D INPUT VOLTAGE : 120 /- 277 VAC N WHITE
BLACK
L
TRP-D BLUE
DRY CONTACTS RED RED
TO LOAD RED

APPLICATIONS:

Use TORK Model TRP-D directly with TORK Digital


Controls Model K400Z/K401Z/K600Z/K601Z/
K800Z/K801Z (dry contact output) where switching of
higher load capacity is necessary.

SWITCH CAPACITY
20A Ballast
20A Incandescent (at 120VAC)
20A General Use
1.0HP at 120VAC

TRP-D 120VAC or 277VAC input

Use low voltage wiring between TORK Digital Control


contacts and TRP-D - minimum 22 AWG, maximum
length 500 feet.

NOVEMBER 2008 15
A DIVISION OF NSi INDUSTRIES, LLC
TYPICAL WIRING WITH 5401 OR 5441
FOR SWITCHING OF GREATER LOADS
DRY CONTACT OUTPUT

TORK DIGITAL CONTROL


TERMINAL BLOCK
CH 1 CH 2 CH 3 CH 4
SPDT SPDT SPDT SPDT

C NO NC C NO NC C NO NC C NO NC

L
120 VAC
N

LINE 120/240/ LINE 120/240/ LINE 120/240/ LINE 120/240/


277/480VAC 277/480VAC 277/480VAC 277/480VAC

120VAC 120VAC 120VAC 120VAC


COIL COIL COIL COIL

LOAD 40A MAX PER POLE LOAD 40A MAX PER POLE LOAD 40A MAX PER POLE LOAD 40A MAX PER POLE

APPLICATIONS:

TYPICAL WIRING OF TORK CONTACTORS


5401, 5441 TO MULTI-CHANNEL K400Z/
K401Z/K600Z/K601Z/K800Z/K801Z

Use where increased voltage and/or amperage switch-


ing is necessary, close to or remote from controller.
Can switch up to 40 amps per pole from 120VAC to
480VAC.

16
APPLICATIONS GUIDE

TIME SWITCH DIMS LIGHTING DURING


SELECTED PERIODS
TORK 1101-FM TIMER

M
Typical wiring with TORK electromechanical time switch
for automatic switching of POULTRY HOUSE lighting.
Bright lighting to simulate daylight - dim lights for roost-
ing. LOW VOLTAGE
AUXILLARY SWITCH
L 1 X 2 NO C

BRIDGE
L
120VAC
N

BRIGHT LIGHTING
UP TO 4000 WATTS
DIM LIGHTING
UP TO 2000 WATTS

not used
BLACK

BLACK
BLUE

RED
WHITE
BLACK

RED
TRP-D
RED

TIME SWITCH OPERATING WITH MOMENTARY


CONTACT SYSTEM
TORK Model 1101 SPST time switch for scheduled
ON-OFF is connected to an SMC-3D momentary
contact adapter. For operation of mechanically-held
contactors and low voltage relays where remote
momentary push button stations are necessary or
already exist.
TORK 1101 SPST
For outdoor lighting, Z kit astronomic dial is easily
adaptable to Models 1101.
FOR SEPARATE MOTOR
M
REMOVE BRIDGE FROM
TERMINALS L & 1
L 1 X 2

BRIDGE
L
120VAC
N

SMC-3D
120VAC
MOMENTARY CONTACTS
ADAPTER SMC-3D ON RELAY
NC NO C
OFF RELAY
NC NO C

ON PULSE PUSH
LOW VOLTAGE ON
LATCHING RELAY
OR MECHANICALLY OFF PULSE
HELD CONTACTOR PUSH
H OFF
120VAC
NEUTRAL N

NOVEMBER 2008 17
A DIVISION OF NSi INDUSTRIES, LLC
MECHANICAL TIME SWITCHES AND PHOTOCONTROL
OPERATING WITH MOMENTARY CONTACT SYSTEM
TORK MODELS
TORK Model 2000, 2001 or 2101 photocontrol is 2000/2001/2021
wired in series with Model 1101 or 1102 time switch TORK 1101 SPST 2101/3000
for photocontrol ON/timed OFF in connection with an
SMC-3D momentary contact adapter. For operation of
mechanically-held contactors and low voltage relays REMOVE BRIDGE FROM M PHOTO
where remote momentary push button stations are nec-
TERMINALS L & 1 CONTROL
essary or already exist. L 1 X 2

L
BLACK
RED
120VAC
N WHITE

SMC-3D
120VAC
MOMENTARY CONTACTS
ADAPTER SMC-3D ON RELAY
NC NO C
OFF RELAY
NC NO C

ON PULSE PUSH
LOW VOLTAGE ON
LATCHING RELAY
OR MECHANICALLY OFF PULSE
HELD CONTACTOR PUSH
H OFF
120VAC
NEUTRAL N

TIME SWITCH/PHOTOCONTROL SWITCHING GREATER


LOAD CAPACITIES
Use TRP-D for direct switching of remote lighting loads
by photocontrol / time switch.

Applicable for 20 Amp Ballasst TORK MODELS


20 Amp Incandescent (at 120VAC) 2000/2001/2021
2101/3000 TORK TIME CONTROL
TERMINAL BLOCK
(OPTIONAL)
PHOTO NO C
CONTROL

L BLACK
120VAC
WHITE
N

RED
NOT USED

LIGHTING LOAD
BLACK

BLACK
BLUE

20A MAX
RED

WHITE
BLACK
TRP-D
RED
RED

18
APPLICATIONS GUIDE

SPRING-WOUND TIMER OPERATING WITH


MOMENTARY CONTACT SYSTEM
TORK A500 SERIES TORK SSA 100/200 SERIES
TORK A500 series spring-wound timer or SSA100/ OR
SSA200 electronic interval timer for timed override, is INTERVAL TIMER ELECTRONIC INTERVAL TIMER
connected to an SMC-3D momentary contact adapter. BLACK
For operation of mechanically-held contactors and low
voltage relays where remote momentary push button RED
stations are necessary or already exist.
GREEN

L
120VAC
N

SMC-3D
120VAC
MOMENTARY CONTACTS
ADAPTER SMC-3D ON RELAY
NC NO C
OFF RELAY
NC NO C

ON PULSE PUSH
LOW VOLTAGE ON
LATCHING RELAY
OR MECHANICALLY OFF PULSE
HELD CONTACTOR PUSH
H OFF
120VAC
NEUTRAL N

FOR INCREASED AREA COVERAGE,


ONE TRP-D POWERPACK CAN OPERATE A MAXIMUM OF
4 OSC5U/OSC10U/OSC20U/OSCW5P/PSCW15P/OSC20UP SENSORS

L
Use TRP-D for direct
120 OR 277 VAC
switching of remote N
lighting loads by
photocontrol / time
switch.
LIGHT LIGHT
FIXTURE FIXTURE WHITE BLACK
Applicable for BLACK BLUE
20 Amp Ballasst TRP-D RED
RED
20 Amp Incandescent RED
(at 120VAC)
RED
BLUE
BLACK
LOW VOLTAGE
3 CONDUCTOR 22GA CLASS 2 WIRING

CEILING MOUNTED OCCUPANCY SENSORS UP TO 4 UNITS OF THE FOLLOWING SENSORS:


OSC5U / OSC10U / OSC20U
OSCW5P / OSCW15P / OSC20UP

NOVEMBER 2008 19
A DIVISION OF NSi INDUSTRIES, LLC
FOR MULTI CIRCUIT CONTROL, A MAXIMUM OF 5 TRP-D
POWERPACKS CAN BE CONNECTED TO ONE OSC5U/OSC10U/
OSC20U/OSCW5P/OSCW15P/OSC2UP
SENSOR

L
120 OR 277 VAC WHITE
N BLACK
LIGHT LIGHT BLACK
FIXTURE FIXTURE TRP-D BLUE
RED
RED
RED

L
120 OR 277 VAC WHITE
N BLACK
LIGHT LIGHT BLACK
BLUE
FIXTURE FIXTURE TRP-D RED
RED
RED

L
120 OR 277 VAC WHITE
N BLACK
LIGHT LIGHT BLACK
BLUE
FIXTURE FIXTURE
RED
TRP-D RED
RED

RED
BLUE
BLACK
LOW VOLTAGE
3 CONDUCTOR 22GA CLASS 2 WIRING
(CONNECT ALL LIKE-COLORED WIRES)

CEILING MOUNTED OCCUPANCY SENSORS

OSC5U / OSC10U / OSC20U


OSCW5P / OSCW15P / OSC20UP

20
APPLICATIONS GUIDE

OCCUPANCY SENSORS FOR LOW VOLTAGE LIGHTING SYSTEMS


USING TORK MODEL SMC-3D
NOTES:

1. For increasing area coverage, a maximum of 4 OSC5U/OSC10U/OSC20U/OSCW5P/OSCW15P/OSC20UP


sensors can be connected.
2. For additional loads, a maximum of twenty (20) latching relays can be connected to each SMC-3D
3. To override load OFF when exiting, momentary push-button switches can be installed at strategic locations.

LOW VOLTAGE
3 CONDUCTOR 22GA CLASS 2 WIRING
(CONNECT ALL LIKE-COLORED WIRES)
RED RED WHITE N
BLUE BLUE BLACK 120 VAC
L
TRP-D RED
BLACK BLACK RED

CEILING MOUNTED OCCUPANCY SENSORS


UP TO 4 OF THE FOLLOWING SENSORS:
OSC5U / OSC10U / OSC20U
OSCW5P / OSCW15P / OSC20UP
SMC-3D
120 VAC
ON RELAY OFF RELAY MOMENTARY
NO C NC NO C NC OVERRIDE
24 VOLT SECONDARY SWITCHES
TRANSFORMER
TORK MODEL
TA 1245Y-75 (75VA) PUSH
ON
BLACK
PUSH
RED
OFF
BLUE
BLACK
RED
BLUE

GE RR-7 RELAYS CONNECT LIKE-COLORED


REQUIRE A DIODE
FOR HALF-WAVE WIRES TOGETHER
OPERATION
OR EQUIVALENT
RELAY GE RR-7

SELECT A TRANSFORMER
SUFFICIENT TO DRIVE
THE NUMBER OF LATCHING
RELAYS USED

UP TO 20 LATCHING RELAYS
CAN BE SWITCHED BY ONE SMC-3D
TO LOAD

TO LOAD

TO LOAD

TO LOAD

TO LOAD

TO LOAD

LOW VOLTAGE LATCHING RELAYS (DRY CONTACTS)

NOVEMBER 2008 21
A DIVISION OF NSi INDUSTRIES, LLC
TIME SWITCH DETERMINING PERIODS DURING
WHICH OCCUPANCY SENSOR IS OPERATING
TORK TIME CONTROL
L TERMINAL BLOCK
120 OR 277 VAC
N NO C NC

WHITE
LOAD BLACK
BLUE
BLACK
RED
TRP-D
RED
RED

LOW VOLTAGE
3 CONDUCTOR 22GA CLASS 2 WIRING
To control what time of day the occupancy sensor is in
operation determined by a TORK digital or mechani-

BLACK
BLUE
RED
cal time switch. TRP-D can be mounted close to load
and sensor can be installed up to 500’ away using
#22 AWG low voltage wire. TORK digital or mechan- OSC5U / OSC10U / OSC20U
OSCW5P / OSCW15P / OSC20UP
ical time switch can be installed anywhere between OCCUPANCY SENSOR
the TRP-D and sensor.

OSWS9P OCCUPANCY SENSOR OR SSA100/SSA200


INTERVAL TIMER SWITCHING GREATER LOAD CAPACITIES
BY USING TRP-D

N
120 OR 277 VAC
L

LOAD
TORK OCCUPANCY SENSOR

BLACK #22 AWG WIRES


WHITE
OSWS9PD BLACK BLUE
OSWS9P-120 BLACK
OSWS9P-277
RED
TRP-D
OSWS9PDM RED RED
RED
GREEN
NOTE: RED & BLUE WIRES MUST BE CONNECTED.
BLACK WIRE NOT USED.
NOTE: THE TRP SHOULD BE MOUNTED CLOSE TO THE LOAD
OR
TORK SSA 100/200 SERIES
ELECTRONIC INTERVAL TIMER

22
APPLICATIONS GUIDE

UTILIZING OCCUPANCY SENSORS OR ELECTRONIC


INTERVAL TIMERS FOR THREE-WAY SWITCHING
Note: For grounding, follow
installation instructions which
are provided with units.

USE TWO OF THE FOLLOWING:


N
TORK OCCUPANCY SENSOR 120 OR 277 VAC
L
OSWS9PD
OSWS9P-120 BLACK RED
OSWS9P-277
OSWS9PDM
GREEN

OR
GROUND
TORK ELECTRONIC INTERVAL TIMER BLACK RED
SSA100 LOAD
SSA200 GREEN

GROUND

INEXPENSIVE THREE-WAY SWITCHING


For simple installation of 3-way switching without the
need for running additional line voltage wiring. A
TRP-D can be installed next to lighting load and #22
AWG low voltage wire can be used between the
TRP-D and standard maintained 3-way switches.

3-WAY 3-WAY
WALL SWITCH WALL SWITCH
BLACK WIRE
NOT USED
BLACK

120 OR 277 VAC


BLUE

RED

N WHITE
BLACK
L
TRP-D
RED
LOW VOLTAGE WIRING
RED MINIMUM 22AWG

NOVEMBER 2008 23
A DIVISION OF NSi INDUSTRIES, LLC
NOTES

TORK TECHNICAL INFORMATION: 888.500.4598

NSi INDUSTRIES, LLC • USA • 800.321.5847 • WWW.NSIINDUSTRIES.COM