Calibration Certificate
IS0 9001 CERTIFIED
Issued to,
Certificate No.: 220609JSR/MVE/0145
Ms. MAA VINDHYAWASINI ENTERPRISES
Noonidh New Colony, P.O- Jitpur, Dist-Dhanbad-828 309
Date: 25.06.2022
Jharkhand
Date of Calibration
Recommended Due Date Page No.
22.06.2022
22.06.2023 1 of 1
Date of Receipt
:22.06.2022
Description of instrument to be calibrated
D-SHACKLE
Traceability: Standards used for calibration are traceable to National Standards through NABL accredited
Environmental conditions of measurement laboratory
:Temp: 33 2 °C.
Humidity: 50+5 %
PERFORMANCE CHECKING
The D-Shackle has been able to lift up
to 6.58Ton load.
Before lifting the Dead loads by D- Shackle those were checked
ring and accessories. through reference force proving
The load has been lift by D- Shackle up to 3 metre from surface and
transfers the same for
preper distance.
AUTHORISEDSIGNATORY
ECA
TAR DAS
Howrah IN CHARGe (cLIBRATION)
Apartment No. D 1, 3rd Floor, 36, Kantapukur 3rd Bye Lane, Howrah 711 101
ASURE Ph.: 033 26670835, 9674756762, website: www.technomeasurenabl.com
E-mail: technomeasure@gmail.com ISO 9001 CERTIFIED
Calibration Certificate
Details of Major Equipments used for Calibration: Dynamometer 100KN(SI.No-AWON. 100 KN. 55702)
Traceability: Standards used for calibration are traceable to National Standards through NABL accredited laboratory
Environmental con ons of measurement Temp: 33 +2 °C
Humidity: 50+5 %
PERFORMANCE CHECKING
The D- Shackle has been able to lift up to 6.54Ton load.
Before lifting the Dead loads by D- Shackle those were checked through reference force proving
ring and accessories.
The load has been lift by D- Shackle up to 3 metre from surface and transfers the same for
proper distance.
Howrah IN CHARGe(CALiBRATION)
a1
RI
NABL: CC-2020
ieReseardhhSitttte
22/44, Ganganegar P. O., Near Sanjay Founders,
ICHALKARANJI-416116
(DisL.Kolhapur), Maharashtra State, INDIA
Phone:(0230) 2441475 Cell:98500 65882
E-mail: fieresearch@gmalil.com Webeite:
Accreditation No. NABL CÇ-2029 www.fr+cal.com
CALIBRATION CERTIFICATE
ULR No.CC202920000004098F OF FORCE MEASURING DEVICE
Date of Calibration 13/10/2020 Certificate No. FRU1O/20/12709
Next Callbraton due on : 13/12/2022 Date of lssue 13/10/2020
Parameter Force Page No. 1/2
Calibrated for Essjay Technomeasure (P) Ltd.,
36, Kantapukur, 3 Bye Lane, Flat No. D1,3 Floor,
P.O.: Kadmtala Dist: Howrah 711 101 (West Benga)
Customer Reference No.
:Challan No.: TMICALI229/20-21 Dated 21/09/2020
Details of instnument under calibralion :Instrument : Dynamometer
Sr. No. AWON.100 kN.55702
Capacity 100 kN
Type : Bow
Dial Gauge Make Mitutoyo
Div. :0.01 mm
Dial Gauge No. :BAM649
Fulcrum Pin No. :702
Temperature :24C