Professional Documents
Culture Documents
Cividec Case Study - 12 07 22
Cividec Case Study - 12 07 22
About Element Six CVD diamond “Plasma diagnostics and control are an
• Synthetic CVD diamond engineered for optical,
thermal, acoustic, quantum and sensing immense technical challenge for the next
applications generation of fusion energy reactors currently
• Element Six launched Electronic Grade Single being constructed. Element Six is proud to
Crystal range as an ideal high energy particle be a solutions provider for cutting-edge, high
detector semiconductor, leveraging over 30
years of innovation leadership and a wide patent temperature neutron detectors, which represent
portfolio in single crystal CVD diamond a critical part of these fusion experiments”
• The ELSC™ Series combines 100% charge
collection efficiency, energy resolution, fast Dr Tim Mollart
response, high temperature stability and Principal Application Engineer, Element Six
outstanding radiation hardness
Why single crystal diamond? The collaboration
Intrinsic diamond possesses remarkable semiconductor Having a long-standing and close relationship in CVD
properties that enable high performance solid state Diamond Radiation Detector Development at CERN, Prof.
detector devices, which can be operated in high radiation Erich Griesmayer chose to launch CIVIDEC in 2009, two
environments for many years. The control over bulk and years after Element Six introduced its Electronic Single
surface defects that the CVD diamond synthesis process Crystal (ELSC) Grade diamond. With an initial focus on
provides has enabled production of diamond crystals with Large Hadron Collider (LHC) beam line diagnostics, work
unparalleled performance in detector applications. on developing neutron detectors began with experiments in
the neutron time-of-flight (n_TOF) facility at CERN in 2010.
• Diamond detectors operate with high bias voltages, Since then, Element Six has provided CIVIDEC with:
very low leakage currents and low power consumption
in high radiation environments • Developed and improved ELSC grades
• Compared to silicon-based devices, diamond • Expert support on diamond material solutions
solutions are temperature independent and insensitive • Access to early-stage prototype devices
to visible light
• New solutions for targeted applications and markets
• The high mobilities and a charge lifetime of 1 µs
enable energy selective detectors and spectroscopic
A leading diagnostic instrumentation supplier to the high
applications with a resolution of 20 keV
energy particle detector community, CIVIDEC has been
• The large atom displacement energy of 42 eV a natural collaborator for Element Six’s unique diamond
enables unparalleled radiation tolerance and lifetimes capabilities. As each generation of particle accelerators,
in extreme fluence >1015 particles cm-2 applications fusion experiments and synchrotron light sources reaches
• Diamond detectors have low absorption cross section ever higher energy levels, diamond solid state solutions
and extreme dynamic range, making them ideal as have emerged to supplant silicon in critical applications.
insertion monitoring devices, such as instrumented
collimators
For more information about Element Six For more information about CIVIDEC
CVD diamond solutions please contact: Instrumentation please contact:
E technologies@e6.com E office@cividec.at
T +44 1344 638 200 T +43 1 922 9307
W cividec.at