Join us to create

a sustainable
future

Lower CO2 equivalent


and market-leading efficiencies

CO ErP 2021
COMPLIANT

Lower CO2 Industry-leading Flexibility to take care Variable Refrigerant


equivalents real life efficiencies of every room Temperature
Creating a sustainable future
together
Determined to reduce our environmental footprint, we aim to be CO₂-neutral by 2050.
A circular economy, innovation and smart use – these are the stepping stones on our path.

The time to act is now. Join us in creating a sustainable future for HVAC-R.

INNOVATION

CIRCULAR ECONOMY SMART USE

www.daikin.eu/building-a-circular-economy

2
INNOVATION

2013 + 2016 + 2017 + 2018 + 2020


First R-32 split Full range of optimised Full range of Launch of
Launch of
Ururu Sarara Split R-32 units optimised Sky Air R-32 Daikin Altherma VRV 5 on R-32
First R-32 Sky Air units heat pump range
Launch of HFO chillers on R-32

Continuing our path to lower CO2 equivalent solutions though innovation


Since the launch of Ururu Sarara in 2013, the first air conditioner to use R-32 refrigerant, we have worked to convert our portfolio to lower GWP
refrigerants. The launch of the VRV 5 S-series, a completely newly developed unit specifically for R-32 refrigerant, is the latest evolution.

-71%
Advantages of R-32 100%

› Lower Global Warming Potential (GWP): 71%


only 1/3rd of R-410A
› Lower refrigerant charge: 15% less
compared to R-410A
› Higher energy efficiency R-410A R-32
› Single component refrigerant, easy to
handle and recycle Potential global warming impact potential global warming impact

Ahead of the F-gas phase down targets


Thanks to the shift to R-32 we stay ahead of the F-gas regulation phase-down targets. In times where the VRV market is growing fast,
this enables us to do our business in a sustainable way, while securing future growth.

With people in mind


Daikin has the ambition to bring you:
- the most sustainable system;
- easy and versatile to install;
- with credible data.

Industry-leading
ErP 2021 real life efficiencies
COMPLIANT

3
The best VRV
we ever made
Lower CO2, equivalent and
market-leading versatility

Top sustainability
Reduced CO2 equivalent thanks to the use of R-32 refrigerant CO
› R-32 Global Warming Potential (GWP) is 68% lower than R-410A
› 15% less refrigerant charge
Leading to a GWP reduction of 71% on system level!

Single component refrigerant, easy to re-use and recycle


ErP 2021
COMPLIANT

Top sustainability over the entire lifecycle, thanks to market leading real-life seasonal efficiency

Ideal for your green building certification, thanks to lower GWP refrigerant

Industry-leading serviceability and handling


Low-height single fan range

Easy to transport thanks to compact design

Wide access area to easily reach all key components

No leak check requirement for majority of installations (up to 7,4 kg of total charge)

4
Maximum flexibility out of the box
With Shirudo technology your VRV 5 system takes care of small room applications in your building, without the need for any additional
considerations and equipment in the field.
› Fully compliant with the latest product standard IEC60335-2-40 (Ed.6)
› Third party CB certified by a Notified Body (SGS CEBEC)

Automatic and real time leak detection, alarm and refrigerant recovery

Shîrudo technology minimizes furthermore the risk of direct CO2 eq. impact from a refrigerant leak.

The system is continuously self monitoring, and in the unlikely event of a refrigerant leak, this is
immediately detected. An alarm is activated to notify tenants, while refrigerant is automatically recovered.

Best-in-class design versatility 3 21


54
Sound pressure down to 39 dB(A) thanks to 5 low sound steps
to suit the application

Automatic ESP setting up to 45 Pa to allow ducting


ESP up to 45 Pa Sound pressure
Low height, less then 1m high including support feet, down to 39 dB(A)

making the unit easy to hide

Geared for comfort


Intuitive online and voice control

Interfaces with home control systems

Variable Refrigerant Temperature for optimal comfort

Specially designed new 10 class indoor unit for small, well-insulated rooms

5
Did you know …
different standards regarding F-gas safety regulations exist?
Two standards are applied to cover the safety regulations of refrigerants:
› EN378:2016: the generic standard on refrigerants covering the toxicity of the refrigerant (class A or B)
› IEC60335-2-40 (Ed.6): the specific heat pump product standard covering the flammability of the refrigerant (1, 2L, 2, 3)

When is which standard applicable?


IEC60335-2-40 (Ed.6), being a specific product standard, Follow
prevails over any generic product standard, like EN 378:2016
16.0 concerning
EN378:2016 is. toxicity Follow
14.0 IEC 60335-2-40 (Ed.6)

Total Refrigerant Charge (kg)


concerning
Considering also that limitations for flammability for 12.0 flammability

A2L refrigerants are stricter than the ones for toxicity, 10.0
the application area of VRV 5 is covered by
IEC60335-2-40 (Ed.6)! 8.0

6.0
EN378:2016 Toxicity limit R-32
4.0
Very strict safety measures; installation not
2.0 possible (similar to R-410A situation today)

0.0
0 20 40 60 80 100
Minimum room surface (m2)

How to get the most of an R-32 VRV under IEC60335-2-40 (Ed.6​)?


The product standard IEC60335-2-40 (Ed.6) specifies the following:
› The minimum room surface that needs to be respected, in function of the total refrigerant quantity of the system.
› The measures that can be implemented to relax limitations on minimum room surface in relation to the system’s total refrigerant charge.

​ ossible measures towards flammability


P
› Manufacturers have the choice to implement zero, one or two measures
› 3 types of measures are allowed:
› Ventilation (natural or mechanical)
› Shut-off valves
› Alarm (local and supervisor)

The true flexibility of a system is highly depending on keeping the considerations needed to select, install and maintain a system to
the minimium. Daikin has 2 factory-integrated measures, undertaking full responsibility about compliance to product standard and
offering maximum flexibilty if some simple installation requirements are respected.

Overview of room area limitation by EN378:2016 and IEC60335-2-40 (Ed.6)


Overview of minimum room surface in function of applied measures under IEC60335-2-40 (Ed.6), considering units are installed at minimum 1.8 m height and
above the lowest underground floor.

16.0 Area 1: application area without any measures


DAIKIN SHÎRUDO TECHNOLOGY: › Typically split and Sky Air systems fall in this area thanks
14.0 2 MEASURES to very low refrigerant charges.
FACTORY-MOUNTED
12.0
› A typical mini VRV installation, with 6.5 kgs of refrigerant
would require a minimum room surface of 39 m²
Total Refrigerant Charge (kg)

Area 2
Area 3
10.0
Area 2: application area with 2 measures integrated
8.0 › Daikin Shîrudo technology enables to use the VRV
6.5 system to it‘s full potential with a minimum room
6.0 surface down to 10 m² (1)
Area 1: no additional measures
4.0 Highly increased
flexibility thanks to required under IEC60335-2-40 Ed.6 (1) For applications below 10 m2 contact your local Daikin representative.

factory-mounted
2.0 measures Reaction time of Extended application
Daikin VRV 5 system area of VRV 5
0.0 20 39 40 60 80 100 Refrigerant charge for a Application area
10.0 typical mini VRV installation without any measures
Minium room surface (m2) with 90~110m pipe length

6
Taking care
of every room in your building
With Shirudo technology your VRV 5 system takes are of any room down to 10 m², without
the need for time consuming selections and additional measures to be taken in the field.

With all measures factory-integrated, VRV 5 is the most flexible and quick to design, fully
compliant to the latest product standards.

Maximum flexibility out of the box


› Install in rooms down to 10 m² (1)
› Flexible design as any other VRV system
› WebXpress selection software ensures compliance to the latest product standards

​All refrigerant control measures factory-integrated


Shîrudo technology includes 2 factory measures and sensors built into a VRV 5 system.

Integrated sensors to detect refrigerant leak.


Leak detection activates:

1 Audible and visual alarm 2 Refrigerant recovery and


shut-off valves
› Integrated in the Madoka wired
remote controller. › Refrigerant is automatically
› In case an additional supervisor alarm is
recovered to the outdoor unit.
needed it can be easily integrated via:​
› After recovery, shut-off valves
› The Madoka controller ​
› An output from the VRV system close and the refrigerant is safely
contained.

Compliance taken care of for you


› No study or calculations needed, where and how to install outdoor unit, indoor units or piping
› No need to design and install flammability measures
› Third party CB certified by a Notified Body (SGS CEBEC)

No liability is transferred on consultant or installer side!

Automatic, real time leak detection and Check here how


flexible the VRV 5 is!
refrigerant recovery
› No leak check requirement for majority of installations (up to 7,4 kg of refrigerant charge).
› Fully compliant to product standard (IEC60335-2-40), minimizing the risk of direct CO2 eq. impact
from a refrigerant leak.
› Continuously self monitored system immediately detects any refrigerant leak. When a leak is
detected, an alarm is activated to notify tenants and refrigerant is automatically recovered. Scan or click
7
    

VRV 5 outdoor unit overview


Capacity class (kW)
Model Product name 4 5 6
Air – cooled heat pump

Lower CO2 equivalent and market-leading flexibility


› Compact single fan design saves space and is easy to install
1~ 
UNIQUE › Market-leading serviceability and handling
VRV 5 › Reduced CO2 equivalent thanks to the use of lower GWP R-32 refrigerant and RXYSA-AV1 / AY1
S-series lower refrigerant charge
› Tackle small room applications without any additional measures, thanks to
Shîrudo technology 3~ 

With new
Madoka
BRC1H52W/S/K !

VRV 5 indoor unit overview


Capacity class (kW)
Type Model  Product name 10 15 20 25 32 40 50 63 71 80 100 125 140
360° air discharge for optimum efficiency and comfort

Ceiling mounted cassette

UNIQUE Auto cleaning function ensures high efficiency



 
Intelligent sensors save energy and maximize comfort
Round flow › Flexibility to suit every room layout FXFA-A
cassette › Lowest installation height in the market! Black and
› Widest choice ever in decoration panel designs and colors designer
Unique design that integrates fully flat into the ceiling panels
UNIQUE › Perfect integration in standard architectural ceiling tiles


Blend of iconic design and engineering excellence
Fully flat › Intelligent sensors save energy and maximize comfort FXZA-A
cassette › Small capacity unit developed for small or well-insulated rooms
› Flexibility to suit every room layout

Slim design for flexible installation UNIQUE


Slim › Compact dimensions enable installation in narrow ceiling voids FOR R-32

concealed › Medium external static pressure up to 44Pa


FXDA-A
› Only grilles are visible

Concealed ceiling

ceiling unit
› Small capacity unit developted for small of well-insulated rooms
Auto cleaning
› Reduced energy consumption thanks to DC fan motor
filter option
Concealed Slimmest yet most powerfull medium static pressure unit on the market!
ceiling unit
› Slimmest unit in class, only 245mm
› Low operating sound level
with
medium
› Medium external static pressure up to 150Pa facilitates using flexible ducts of
varying lengths
FXSA-A  
ESP › Automatic air flow adjustment function measures the air volume and static
pressure and adjusts it towards the nominal air flow, guaranteeing comfort
Wall mounted

For rooms with no false ceilings nor free floor space


Wall
› Flat, stylish front panel is more easy to clean
mounted ›
unit ›
Small capacity unit developted for small of well-insulated rooms
Reduced energy consumption thanks to DC fan motor
FXAA-A 
› The air is comfortably spread up- and downwards thanks to 5 different discharge
angles
Cooling capacity (kW)1 1.1 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0
Heating capacity (kW)2 1.3 1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0

(1) Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m
(2) Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m

8
VRV 5 indoor unit benefit overview Ceiling mounted
cassette units
Concealed ceiling units
Wall
moun-
ted
unit

FXFA-A FXZA-A FXDA-A FXSA-A FXAA-A

Home leave operation During absence, indoor comfort levels can be maintained     
Fan only The air conditioner can be used as fan, blowing air without cooling or heating     
We care

The filter automatically cleans itself. Simplicity of upkeep means optimum


Auto cleaning filter energy efficiency and maximum comfort without the need for expensive or  
time-consuming maintenance (optional) (optional)
The presence sensor directs the air away from any person detected in the
Floor and presence sensor room. The floor sensor detects the average floor temperature and ensures an
even temperature distribution between ceiling and floor
 
When starting to warm up or when the thermostat is off, the air discharge
Draught prevention direction is set horizontally and the fan to low speed, to prevent draught.
After warming up, air discharge and fan speed are set as desired
 
Comfort

Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed
Whisper quiet
not to disturb the quiet of the neightbourhood    
Auto cooling-heating
changeover
Automatically selects cooling or heating mode to achieve the set temperature     
G1(2)
treatment

(G3 (2) in case


 
Air

Air filter Removes airborne dust particles to ensure a steady supply of clean air G1(2) G1(2)
of auto cleaning
panel)
Humidity
control

Dry programme Allows humidity levels to be reduced without variations in room temperature     
The air discharge of the indoor unit is specially designed to prevent air being
Ceiling soiling prevention
blown against the ceiling to prevent ceiling stains  
Possibility to select automatic vertical moving of the air discharge louvre, for
Vertical auto swing
uniform air flow and temperature distribution   
Air flow

Fan speed steps Multiple fan speeds to select,to optimize comfort levels 5 + auto 3 + auto 3 3 + auto 3

Individual louver control via the wired remote controller makes it simple
Individual louver control to fix the position of each louver individually, to suit any new room
configuration. Optional closure kits are available as well
 
Daikin residential controller Can control and monitor the status of your Daikin heating or air conditioning
(BRP069C51) system     
Remote control & timer

NEW
Timer can be set to start and stop operation anytime on a daily or weekly
Weekly timer
basis     
Infrared remote control Infrared remote control with LCD to remotely control your indoor unit (1) (1) (1) (1) (1)
Wired remote control Wired remote control to remotely control your indoor unit Only connectable to new BRC1H52W/S/K

Centralised control Centralised control to to control several indoor units from one single point     
Auto-restart The unit restarts automatically at the original settings after power failure     
Other funtcions

Self-diagnosis Simplifies maintenance by indicating system faults or operating anomalies     


Drain pump kit Facilitates condensation draining from the indoor unit Standard Standard Standard Standard Optional

The indoor unit’s main power supply can be turned off


Multi tenant
when leaving the building or for servicing purposes     
(1) Must be combined with Madoka wired remote controller.
(2) Filter grade category are an indication, filters are not certified.
9
Next generation

New asymmetric fan design


› Two high ESP settings
› Low sound levels

Compact dimensions
› Easy to transport thanks to compact size
and single-fan design

New casing design with


4 handles for easy carrying

Specially
designed grille
› Low pressure drop Refrigerant cooled PCB
› No risk for accidental With integrated:
reach of the fan › cool/heat selector input
› 7-segment display for quicker
and more precise error and
setting reading

New stop valves


› Repositioned to allow front
or side connection
› Brazed for increased reliability
Unique 3-row heat exchanger
› Contributes to top seasonal efficiency

Unique Daikin swing compressor


› No abrasion possible
› No refrigerant leak possible
› High seasonal efficiencies

10
NEW RXYSA-AV1/AY1

VRV 5 S-series
1.100 mm 460 mm
Lower CO2 equivalent and market-leading flexibility

› Reduced CO2 equivalent thanks to the use of lower GWP R-32


refrigerant and lower refrigerant charge
› Top sustainability over the entire lifecycle, thanks to market
leading real-life seasonal efficiency
› Low-height single fan range
› Easy to transport thanks to lightweight and compact design 869mm
› Wide access area to easily reach all key components
› Tackle small room applications without any additional measures,
thanks to Shîrudo technology
› Specially designed indoor units for R-32, ensuring low sound and
maximum efficiency
level difference between indoor and outdoor units

RXYSA-AV/AY1
Only
869mm
high!
level difference

120 m longest pipe length


indoor units
15 m

40 m longest length after first branch


between
50 m

CO ErP 2021
COMPLIANT

Already fully compliant


300 m total piping length to LOT 21 - Tier 2
Access all technical information on RXYSA-AV1/AY1 Reduced CO2 equivalent Flexibility to take care Published data with
of every room real-life indoor units
at my.daikin.eu or click here

Outdoor unit RXYSA4AV1 RXYSA5AV1 RXYSA6AV1 RXYSA4AY1 RXYSA5AY1 RXYSA6AY1


Capacity range HP 4 5 6 4 5 6
Cooling capacity
Prated,c kW 12.1 14.0 15.5 12.1 14.0 15.5
Heating capacity
Prated,h kW 8.4 9.7 10.7 8.4 9.7 10.7
Max. 6°CWB kW 14.2 16.0 18.0 14.2 16.0 18.0
Recommended combination 3xFXSA25A2VEB + 4xFXSA32A2VEB 2xFXSA32A2VEB + 3xFXSA25A2VEB + 4xFXSA32A2VEB 2xFXSA32A2VEB
1xFXSA32A2VEB 2xFXSA40A2VEB 1xFXSA32A2VEB + 2xFXSA40A2VEB
ηs,c % 324.5 306.1 301.0 312.5 294.8 289.9
ηs,h % 200.5 185.7 183.6 193.1 178.8 176.8
SEER 8.2 7.7 7.6 7.9 7.4 7.3
SCOP 5.1 4.7 4.7 4.9 4.5 4.5
Maximum number of connectable indoor units 13 (1) 16 (1) 18 (1) 13 (1) 16 (1) 18 (1)
Indoor index Min. 50 62.5 70 50 62.5 70
connection Nom. 100 125 140 100 125 140
Max. 130 162.5 182 130 162.5 182
Dimensions Unit HeightxWidthxDepth mm 869x1,100x460
Weight Unit kg 102
Sound power level Cooling Nom. dBA 67 68.1 69 67 68.1 69
Heating Nom. dBA 68 69.2 70 68 69.2 70
Heating According to ENER LOT21 57 59 60 57 59 60
Sound pressure level Cooling Nom. dBA 49 51 51 49 51 51
Heating Nom. dBA 50 52 52 50 52 52
Operation range Cooling Min.~Max. °CDB -5.0 ~ 46.0
Heating Min.~Max. °CWB -20.0 ~ 16
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 3.40 / 2.30
Piping connections Liquid OD mm 9.52
Gas OD mm 15.9
Total piping system Actual m 300
length
Height OU-IU Outdoor unit in m 50
Difference highest position
Indoor unit in m 40
highest position

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415


Current - 50Hz Maximum fuse amps (MFA) A 32 16

(1) Actual number of units depends on the indoor unit type and the connection ratio restriction for the system (being 50% <= 130%)

11
The most comfortable cassette
just got better

New round flow cassette


› Bigger louvers and new sensor logic further improves equal air distribution in the room

› Widest ever choice in panels for cassette units, with up to 8 different panels

Black auto cleaning panel Black designer panel Full white standard panel White designer panel

› Comes with the known benefits: 360° air flow discharge


and intelligent sensors
presence floor sensor
sensor

› Auto cleaning panels available in black and white

Auto cleaning filter

Dust can simply be


removed using a vacuum
cleaner without opening
the unit.

* Available as an option

12
NEW FXFA-A

Round flow cassette


360° air discharge for optimum efficiency and comfort

› Optimised design for R-32 refrigerant


› Optional automatic filter cleaning results in higher efficiency
& comfort and lower maintenance costs.
› Two optional intelligent sensors improve energy efficiency
and comfort
› Widest choice ever in decoration panels: Designer, standard FXFA-A
and autocleaning panels in white (RAL9010) and black (RAL9005)
› Bigger louvers and unique swing pattern improve equal NEW
air distribution
› Individual louver control: flexibility to suit every room layout
without changing the location of the unit!
› Lowest installation height in the market: 214mm for class 20-63
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in BRC1H52W BRP069C51
irregular shaped rooms or to supply air to small adjacent rooms

Main unit

Branch discharge Main discharge

› Standard drain pump with 675mm lift increases flexibility White panel White auto cleaning panel Black panel Black design panel
and installation speed

Access all technical information on FXFA-A


at my.daikin.eu or click here

Indoor unit FXFA 20A 25A 32A 40A 50A 63A 80A 100A 125A
Cooling capacity Total capacity at high fan speed kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00
Heating capacity Total capacity at high fan speed kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 12.50 16.00
Power input - 50Hz Cooling at high fan speed kW 0.04 0.05 0.06 0.09 0.12 0.19
Heating at high fan speed kW 0.04 0.05 0.06 0.09 0.12 0.19
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 288x840x840
Weight Unit kg 18 19 21 24 26
Casing Material Galvanised steel plate
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow rate - Cooling At high fan speed m³/min 12.8 14.8 15.1 16.6 23.3 28.8 33.0
50Hz Heating At high fan speed m³/min 12.8 14.8 15.1 16.6 23.3 28.8 33.0
Air filter Type Resin net
Sound power level Cooling At high fan speed dBA 49 (4) 51 (4) 53 (4) 55 (4) 60 (4) 61 (4)
Sound pressure Cooling L/ML/M/MH/H dBA 31/30/29/29.5/28 (4) 33 / 32 / 31 /30 / 29 (4) 35 / 34 / 33/32/30 (4) 38/ 36 /34 /32/30 (4) 43/41/37/34 /30 (4) 45/43/41/39 /36 (4)
level Heating L/ML/M/MH/H dBA 31/30/29/29.5/28 (4) 33 / 32/31 /30 /29 (4) 35 / 34 / 33 / 32/30 (4) 38/ 36 /34 /32 /30 (4) 43/41/37/34 /30 (4) 45/43/41/39 /36 (4)
Refrigerant Type/GWP R-32 / 675
Piping connections Liquid OD mm 6.35 9.52
Gas OD mm 9.52 12.7 15.9
Drain VP25 (O.D. 32 / I.D. 25)
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Current - 50Hz Maximum fuse amps (MFA) (1) A 6
Control systems Infrared remote control BRC7FA532F (2)
Wired remote control BRC1H52W/S/K
(1) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing
(2) Must be combined with Madoka wired remote controller.
(3) L/ML/M/MH/H are the different fan speeds availble. L= low; ML= medium low; M= medium; MH= medium high; H= high
(4) Sound of designer panel: +3dB

13
14
NEW FXZA-A

Fully flat cassette


Unique design in the market that
integrates fully flat into the ceiling

› Optimised design for R-32 refrigerant


› Fully flat integration in standard architectural ceiling tiles, leaving
only 8mm
› Remarkable blend of iconic design and engineering excellence
with an elegant finish in white or a combination of silver FXZA-A
and white
› Two optional intelligent sensors improve energy efficiency NEW
and comfort
› 15 class unit especially developed for small or well-insulated
rooms, such as hotel bedrooms, small offices, etc.
› Individual louver control: flexibility to suit every room layout
without changing the location of the unit!
BRC1H52W BRP069C51

› Optional fresh air intake


› Standard drain pump with 630mm lift increases flexibility and
installation speed

Access all technical information on FXZA-A


at my.daikin.eu or click here

Indoor unit FXZA 15A 20A 25A 32A 40A 50A


Cooling capacity Total capacity At high fan speed kW 1.70 2.20 2.80 3.60 4.50 5.60
Heating capacity Total capacity At high fan speed kW 1.90 2.50 3.20 4.00 5.00 6.30
Power input - 50Hz Cooling At high fan speed kW 0.043 0.045 0.059 0.092
Heating At high fan speed kW 0.043 0.045 0.059 0.092
Dimensions Unit HeightxWidthxDepth mm 260x575x575
Weight Unit kg 15.5 16.5 18.5
Casing Material Galvanised steel plate
Decoration panel Model BYFQ60C2W1W
Colour White (N9.5)
Dimensions HeightxWidthxDepth mm 46x620x620
Weight kg 2.8
Decoration panel 2 Model BYFQ60C2W1S
Colour SILVER
Dimensions HeightxWidthxDepth mm 46x620x620
Weight kg 2.8
Decoration panel 3 Model BYFQ60B2W1
Colour White (RAL9010)
Dimensions HeightxWidthxDepth mm 55x700x700
Weight kg 2.7
Decoration panel 4 Model BYFQ60B3W1
Colour WHITE (RAL9010)
Dimensions HeightxWidthxDepth mm 55x700x700
Weight kg 2.7
Fan Air flow rate - Cooling At high fan speed m³/min 8.5 8.7 9.0 10.0 11.5 14.0
50Hz Heating At high fan speed m³/min 8.5 8.7 9.0 10.0 11.5 14.0
Air filter Type Resin net
Sound power level Cooling At high fan speed dBA 49 50 51 54 60
Sound pressure Cooling Low/medium/high fan speed dBA 25.5/28.0/31.5 25.5/29.5/32.0 25.5/30.0/33.0 26.0/30.0/33.5 28.0/32.0/37.0 33.0/40.0/43.0
level Heating Low/medium/high fan speed dBA 25.5/28.0/31.5 25.5/29.5/32.0 25.5/30.0/33.0 26.0/30.0/33.5 28.0/32.0/37.0 33.0/40.0/43.0
Refrigerant Type/GWP R-32 / 675
Piping connections Liquid OD mm 6.35
Gas OD mm 9.52 12.7
Drain VP20 (I.D. 20/O.D. 26)
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Current - 50Hz Maximum fuse amps (MFA) A 6
Control systems Infrared remote control BRC7EB530W (standard panel) / BRC7F530W (white panel) / BRC7F530S (grey panel) (1)
Wired remote control BRC1H52W/S/K
Dimensions do not include control box
(1) Must be combined with Madoka wired remote controller.

15
Auto cleaning filter for
concealed ceiling units

The unique automatic cleaning filter achieves higher efficiency


and comfort with lower maintenance costs
airflow
direction
Reduce running costs

› Automatic filter cleaning ensures low maintenance costs


because the filter is always clean
UNIQUE
Efficiency profile change for duct indoor unit during operation Patents
100% Up to 20% pending
Energy saved
Gradual loss of thanks to
efficiency due automatic filter
to dirty filter cleaning

0%
start 6 months 12 months

Minimal time required for filter cleaning

› The dust box can be emptied with a vacuum cleaner for fast
and easy cleaning How does it work?
› No more dirty ceilings

Improved indoor air quality 1 Scheduled automatic filter cleaning

› Optimum airflow eliminates draft and insulates sound 2 Dust collects in a dust box that’s
integrated into the unit
Superb reliability

› Prevents clogged filters for seamless operation 3 The dust can easily be removed with
a vacuum cleaner
Unique technology

› Unique and innovative filter technology inspired


by the Daikin auto cleaning cassette

Combination table
www.youtube.com/DaikinEurope
Split / Sky Air VRV
Specifications
FDXM-F9 FXDA-A/FXDQ-A3

25 35 50 60 15 20 25 32 40 50 63 BAE20A62 BAE20A82 BAE20A102

BAE20A62       Heigth (mm) 210


BAE20A82   Width (mm) 830 1,030 1,230
BAE20A102    Depth (mm) 188

16
NEW FXDA-A

Slim concealed ceiling unit rear


suction

Slim design for flexible installation

› Optimised design for R-32 refrigerant


› 10 class unit especially developed for small or well-insulated
rooms, such as hotel bedrooms, small offices, etc. outblow
› Compact dimensions, can easily be mounted in a ceiling void
bottom
of only 240mm suction
SERIE A (15, 20, 25, 32)

FXDA-A

200 mm

NEW
700 mm
50 mm

› Medium external static pressure up to 44Pa facilitates unit use


with flexible ducts of varying lengths
› Discretely concealed in the wall: only the suction and discharge
grilles are visible BRC1H52W BRP069C51
› Optional auto cleaning filter option ensures maximum efficiency,
comfort and reliability by regular filter cleaning
› Flexible installation, as the air suction direction can be altered
from rear to bottom suction

› Standard drain pump with 600mm lift increases flexibility


and installation speed

Access all technical information on FXDA-A


at my.daikin.eu or click here

Access all technical information on BAE20A


at my.daikin.eu or click here NEW Auto cleaning filter option

Indoor unit FXDA 10A 15A 20A 25A 32A 40A 50A 63A
Cooling capacity Total capacity At high fan speed kW 1.10 1.70 2.20 2.80 3.60 4.50 5.60 7.10
Heating capacity Total capacity At high fan speed kW 1.30 1.90 2.50 3.20 4.00 5.00 6.30 8.00
Power input - 50Hz Cooling At high fan speed kW 0.042 0.057 0.068 0.075 0.096 0.107
Heating At high fan speed kW 0.042 0.057 0.068 0.075 0.096 0.107
Required ceiling void > mm 240
Dimensions Unit HeightxWidthxDepth mm 200x750x620 200x950x620 200x1,150x620
Weight Unit kg 22.0 26.0 29.0
Casing Material Galvanised steel
Fan Air flow rate - 50Hz Cooling At high fan speed m³/min 5.2 6.5 8.0 10.5 12.5 16.5
External static Factory set/High Pa 10/30.0 15/44.0
pressure - 50Hz
Air filter Type Removable / washable
Sound power level Cooling At high fan speed dBA 48 50 51 52 53 54
Sound pressure level Cooling Low/Medium/High fan speed dBA 26 / 28 / 29 27.0/31.0/32.0 27.0/31.0/33.0 28.0/32.0/34.0 29.0/33.0/35.0 30.0/34.0/36.0
Refrigerant Type/GWP R-32 / 675
Piping connections Liquid OD mm 6.35
Gas OD mm 9.52 12.7
Drain VP20 (I.D. 20/O.D. 26)
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Current - 50Hz Maximum fuse amps (MFA) A 6
Control systems Infrared remote control BRC4C65 / BRC4C66 (1)
Wired remote control BRC1H52W/S/K
(1) Must be combined with Madoka wired remote controller.

17
NEW FXSA-A

Concealed ceiling unit


with medium ESP
Slimmest yet most powerful medium outblow
static pressure unit on the market
rear
› Optimised design for R-32 refrigerant suction

› Slimmest unit in class, only 245mm (300mm built-in height) and bottom
suction
therefore narrow ceiling voids are no longer a challenge FXSA-A

245 mm
NEW

› Quiet operation: down to 25dBA sound pressure level


› Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
› Possibility to change ESP via wired remote control allows BRC1H52W BRP069C51
optimisation of the supply air volume
› Discretely concealed in the wall: only the suction and discharge
grilles are visible › Standard built-in drain pump with 625mm lift increases flexibility
› 15 class unit especially developed for small or well-insulated and installation speed
rooms, such as hotel bedrooms, small offices, etc.
› Optional fresh air intake
› Flexible installation: air suction direction can be altered from rear
to bottom suction and choice between free use or connection
to optional suction grilles
////////////////////////////////////////// ////////////////////////////////////////// //////////////////////////////////////////

For free use into a false For connecting onto a For direct connection to
ceiling suction canvas Daikin panel
(not supplied by Daikin) (via EKBYBSD kit)

External static pressure (Pa)

Automatic Airflow Adjustment function


Automatically selects the most appropriate fan curve to achieve the units’ nominal air flow within ±10%
Fan characteristic Air flow (rated)
curves

Why? Air flow (actual)


After installation the real ducting will frequently differ from the initially calculated air flow resistance  the real air flow may be much lower or higher than
nominal , leading to a lack of capacity or uncomfortable air temperature
Automatic Airflow Adjustment function will adapt the unit’s fan speed to any ducting automatically (10 or more fan curves are a­ vailable on every model), Air flow (with automatic
making installation much faster Duct resistance
curves
adjustment)

± Air flow (m3/min)

Access all technical information on FXSA-A


at my.daikin.eu or click here

Indoor unit FXSA 15A 20A 25A 32A 40A 50A 63A 80A 100A 125A 140A
Cooling capacity Total capacity At high fan speed kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00 16.00
Heating capacity Total capacity At high fan speed kW 1.90 2.50 3.20 4.00 5.00 6.30 8.00 10.0 12.5 16.0 18.0
Power input - 50Hz Cooling At high fan speed kW 0.086 0.147 0.150 0.183 0.209 0.285 0.326 0.382
Heating At high fan speed kW 0.086 0.147 0.150 0.183 0.209 0.285 0.326 0.382
Dimensions Unit HeightxWidthxDepth mm 245x550x800 245x700x800 245x1,000x800 245x1,400x800 245x1,550x800
Weight Unit kg 23.5 24.0 28.5 29.0 35.5 36.5 46.0 47.0 51.0
Casing Material Galvanised steel plate
Fan Air flow rate - 50Hz Cooling At high fan speed m³/min 8.7 9.0 9.5 15.0 15.2 21.0 23.0 32.0 36.0 39.0
Heating At high fan speed m³/min 8.7 9.0 9.5 15.0 15.2 21.0 23.0 32.0 36.0 39.0
External static Factory set/High Pa 30/150 40/150 50/150
pressure - 50Hz
Air filter Type Resin net
Sound power level Cooling At high fan speed dBA 54 55 60 59 61 64
Sound pressure level Cooling Low/Medium./High dBA 25.0/28.0/29.5 25.0/28.0/30.0 26.0/29.0/31.0 29.0/32.0/35.0 27.0/30.0/33.0 29.0/32.0/35.0 31.0/34.0/36.0 33.0/36.0/39.0 34.0/38.0/41.5
Heating Low/Medium/High dBA 26.0/29.0/31.5 26.0/29.0/32.0 27.0/30.0/33.0 29.0/34.0/37.0 28.0/32.0/35.0 30.0/34.0/37.0 31.0/34.0/37.0 33.0/37.0/40.0 34.0/38.5/42.0
Refrigerant Type/GWP R-32 / 675
Piping connections Liquid OD mm 6.35 9.52
Gas OD mm 9.52 12.7 15.9
Drain VP20 (I.D. 20/O.D. 26), drain height 625 mm
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Current - 50Hz Maximum fuse amps (MFA) A 6
Control systems Infrared remote control BRC4C65 (1)
Wired remote control BRC1H52W/S/K
(1) Must be combined with Madoka wired remote controller.

18
NEW FXAA-A

Wall mounted unit


For rooms with no false ceilings nor free floor space

› Optimised design for R-32 refrigerant


› Flat, stylish front panel blends easily within any interior décor
and is easier to clean
› Can easily be installed in both new and refurbishment projects
› The air is comfortably spread up- and downwards thanks
to 5 different discharge angles that can be programmed FXAA-A
via the remote control
› Maintenance operations can be performed easily from NEW
the front of the unit

BRC1H52W BRP069C51

Access all technical information on FXAA-A


at my.daikin.eu or click here

Indoor unit FXAA 15A 20A 25A 32A 40A 50A 63A
Cooling capacity Total capacity At high fan speed kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1
Heating capacity Total capacity At high fan speed kW 1.9 2.5 3.2 4.0 5.0 6.3 8.0
Power input - 50Hz Cooling At high fan speed kW 0.017 0.019 0.028 0.030 0.025 0.033 0.050
Heating At high fan speed kW 0.025 0.029 0.034 0.035 0.030 0.039 0.060
Dimensions Unit HeightxWidthxDepth mm 290x795x266 290x1,050x269
Weight Unit kg 15 18.5
Fan Air flow rate - 50Hz Cooling Low/High m³/min 6.5/7.1 6.5/7.9 6.5/8.3 6.5/9.4 9.8/12.2 10.9/14.2 12.9/18.2
fan speed
Air filter Type Washable resin net
Sound power level Cooling At high fan speed dBA 51.0 52.0 53.0 55.0 58.0 63.0
Sound pressure level Cooling Low/Medium/High dBA 28.5/30.5/32.0 28.5/31.0/33.0 28.5/32.0/35.0 28.5/33.0/37.5 33.5/35.5/37.0 35.5/38.5/41.0 38.5/42.5/46.5
Heating Low/Medium/High dBA 28.5/31.0/33.0 28.5/31.5/34.0 28.5/32.5/36.0 28.5/33.5/38.5 33.5/36.0/38.0 35.5/39.0/42.0 38.5/43.0/47.0
Refrigerant Type/GWP R-32 / 675
Piping connections Liquid OD mm 6.35
Gas OD mm 9.52 12.7
Drain VP13 (I.D. 15/O.D. 18)
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A 6
Control systems Infrared remote control BRC7EA630 (1)
Wired remote control BRC1H52W/S/K
(1) Must be combined with Madoka wired remote controller. | Contains fluorinated greenhouse gases

19
Options & accessories -
Outdoor units VRV S-series
RXYSA-AV1/AY1
Heater tape kit - Optional electrical heater to guarantee trouble-free operation in extremely cold and humid climates EKBPH250D
(one per outdoor unit needed)
DTA104A53/61/62 - For installation into an indoor unit: exact adapter type
External control adapter for outdoor unit - Allows to activate Low Noise Operation and three levels of demand control, limiting power consumption via external dry contacts. depends on type of indoor unit.
Connects to the F1/F2 communication line and requires power supply from an indoor unit, BSVQ box, or VRV-WIII outdoor unit. For 14-20 HP the demand PCB mouting plate is required. See Options &
Adapters

Accessories of indoor units


KRC19-26A - Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to •
the A-B-C terminals of the outdoor unit / BS-box.
Cool/heat selector PCB (required to connect KRC19-26A) Standard on unit
Others

KJB111A - Installation box for remote cool/heat selector KRC19-26A •


EKPCCAB4 - VRV configurator •

Indoor units Ceiling mounted cassette units Concealed ceiling units (duct units)
Round flow (800x800) 4-way (600x600) Slim
FXFA-A FXZA-A FXDA-A
Standard panels:
Decoration panel (obligatory for cassette units, optional BYCQ140E (white) / BYCQ140EW (full white)(3) / BYCQ140EB (black) BYFQ60C4W1W (white panel) (19) / BYFQ60C4W1S (grey panel)
for others, rear panel for FXLQ) Auto cleaning (5)(6): BYCQ140EGF (white) / BYCQ140EGFB (black) (19) / BYFQ60B3W1 (standard panel) (20)
Designer panels: BYCQ140EP (white) / BYCQ140EPB (black)
Panels

Panel spacer for reducing required installation height KDBQ44B60 (standard panel)
Sealing kit for 3- or 2-directional air discharge KDBHQ56B140 (7) BDBHQ44C60 (white & grey panel)
BRYQ140B (white panels)
Sensor kit BRYQ140BB (black panels) BRYQ140C (white designer panel) R-32 models: BRYQ60A3W (white) / BRYQ60A3S (grey)
BRYQ140CB (black designer panel)
BRC7FA532F (white panels) / BRC7FA532FB (black panels) BRC7F530W (9) (10) (white panel) / BRC7F530S (9) (10)
Individual control systems

Infrared remote control (incl. receiver) BRC4C65


BRC7FB532F (white designer panel) /BRC7FB532FB (black designer panel) (grey panel) / BRC7EB530W (9) (10) (standard panel)
BRP069C51 - Online controller • • •
Madoka - BRC1H52W (White) / BRC1H52S (Silver) /
BRC1H52K (Black) - User-friendly wired remote controller
with premium design
• (mandatory for R-32) • (mandatory for R-32) • (mandatory for R-32)

BRC1E53A/B/C - Wired remote control with full-text


interface and back-light • (18) • (18) • (18)
BRC1D52 (4) - Standard wired remote control with
weekly timer • (15) (18) • (18) • (18)

DCC601A51 - Intelligent Tablet Controller


• • •
Centralised control

DCS601C51 (12) - Intelligent Touch Controller


• • •
systems

DCS302C51 (12) - Central remote controller


• • •
DCS301B51 (12) (13) - Unified ON/OFF controller
• • •
DST301B51 (12) - Schedule timer
• • •
RTD-NET - Modbus interface for monitoring and control
• • •
for individual control

RTD-10 - Modbus interface for infrastructure cooling


• • •
Building Management System &
Standard protocol interfaces

RTD-20 - Modbus interface for retail


• • •
RTD-HO - Modbus interface for hotel
• • •
KLIC-DI - KNX Interface
• • •
DCM601A51 - Intelligent Touch Manager
• • •
for central control

EKMBDXB - Modbus interface


• • •
DCM010A51 - Daikin PMS interface
• • •
DMS502A51 - BACnet Interface
• • •
DMS504B51 - LonWorks Interface
• • •
Replacement long life filter, non-woven type KAFP551K160 KAFQ441BA60
Filters

Auto cleaning filter see decoration panel 15-32: BAE20A62 / 40-50: BAE20A82 / 63: BAE20A102
sensors
Wiring

KRCS - External wired temperature sensor KRCS01-7B KRCS01-8B KRCS01-8B


and

K.RSS - External wireless temperature sensor SB.K.RSS_RFC (EKEWTSC-2 + K.RSS) SB.K.RSS_FDA (EKEWTSC-1 + K.RSS) SB.K.RSS_FDA (EKEWTSC-1 + K.RSS)
Adapter with 2 output signals (Compressor / Error, Fan output) KRP1BA58 (2)(7) ERP02A50 (2)
Adapter with 4 output signals (Compressor / Error, Fan,
EKRP1C12 (2)(7) EKRP1C14 (2) ERP02A50
Aux. heater, Humidifier output)
Adapter for centralised external monitoring/control via
KRP4A53 (2)(7) KRP4A53 (2) KRP4A54-9
dry contacts and setpoint control via 0-140Ω
Adapter for external central monitoring/control
KRP2A52 KRP2A53
(controls 1 entire system)
Adapters

Adapter for keycard and/or window contact connection


BRP7A53 BRP7A53 BRP7A54
(2)(11)
External control adapter for outdoor unit (installation
DTA104A53
on indoor unit)
Installation box / Mounting plate for adapter PCBs KRP1H98A (7) KRP1BB101
KRP1BB101
(For units where there is no space in the switchbox) KRP1BC101 KRP1BC101
Wiring kit for Remote ON/OFF or Forced OFF Standard Standard
Relay PCB for output signal of refrigerant sensor ERP01A51 ERP01A50 (2) ERP01A51
Drain pump kit Standard Standard Standard
Others

Fresh air intake kit (direct installation type) KDDP55C160-1 + KDDP55D160-2 (7)(8) KDDQ44XA60
Air discharge adapter for round duct

(1) Pump station is necessary for this option. (5) To be able to control the BYCQ140EGF(B) the controller BRC1E or BRC1H* is needed.
(2) Installation box is necessary for these adapters. (6) The BYCQ140EGF(B) is not compatible with Multi and Split Non-Inverter Outdoor units.
(3) The BYCQ140EW has white insulation. Be informed that formation of dirt on white insulation is (7) Option not available in combination with BYCQ140EGF(B).
visibly stronger and that it is consequently not advised to install the BYCQ140EW decoration panel in (8) Both parts of the fresh air intake are needed for each unit.
environments exposed to concentrations of dirt. (9) Cannot be combined with sensor kit.
(4) Not recommended because of the limitation of the functions. (10) Independently controllable flaps function not available .

20
Concealed ceiling units (duct units) Wall mounted units
Medium ESP
FXSA15-32A FXSA40-50A FXSA63-80A FXSA100-125A FXSA140A FXAA-A

BRC4C65 BRC4C65 BRC4C65 BRC4C65 BRC4C65 BRC7EA630 / BRC7EA628

• • • • • •
• (mandatory for R-32) • (mandatory for R-32) • (mandatory for R-32) • (mandatory for R-32) • (mandatory for R-32) • (mandatory for R-32)

• (18) • (18) • (18) • (18) • (18) • (18)

• (18) • (18) • (18) • (18) • (18) • (18)

• • • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • •
• • • • •
• • • • •
• • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • •
• • • • • •
• • • • • •

KRCS01-4 KRCS01-4 KRCS01-4 KRCS01-4 KRCS01-4 KRCS01-8B


SB.K.RSS_RFC (EKEWTSC-2 + K.RSS) SB.K.RSS_RFC (EKEWTSC-2 + K.RSS) SB.K.RSS_RFC (EKEWTSC-2 + K.RSS) SB.K.RSS_RFC (EKEWTSC-2 + K.RSS) SB.K.RSS_RFC (EKEWTSC-2 + K.RSS) SB.K.RSS_FDA (EKEWTSC-1 + K.RSS)

EKRP1C14 EKRP1C14 EKRP1C14 EKRP1C14 EKRP1C14 ERP02A50 (2)

KRP4A52(2) KRP4A52(2) KRP4A52(2) KRP4A52(2) KRP4A52(2) KRP4AA51 (2)

KRP2A51(2) KRP2A51(2) KRP2A51(2) KRP2A51(2) KRP2A51(2) KRP2A51 / KRP2A61(2)

BRP7A51 BRP7A51 BRP7A51 BRP7A51 BRP7A51 BRP7A51 (2)

DTA104A61 DTA104A61 DTA104A61 DTA104A61 DTA104A61 DTA104A51(2) / DTA104A61(2)


KRP1BB101/ KRP1BB101/ KRP1BB101/ KRP1BB101/ KRP1BB101/
KRP4AA93 (16)(17)
KRP1BC101 KRP1BC101 KRP1BC101 KRP1BC101 KRP1BC101
Standard Standard Standard Standard Standard Standard
ERP01A50 ERP01A50 ERP01A50 ERP01A50 ERP01A50 ERP01A51 (2)
Standard Standard Standard Standard Standard K-KDU572KVE

KDAP25A36A KDAP25A56A KDAP25A71A KDAP25A140A

(11) Only possible in combination with BRC1H* / BRC1E*. (16) Up to 2 adaptor PCBs can be installed per installation box.
(12) When fixing box is required, use KJB212A, KJB311A or KJB411A depending on the size of (17) Only one installation box can be installed per indoor unit.
the controller. (18) VRV R-32 indoor units cannot be connected to this controller.
(13) Option KEK26-1A (noise filter) is required when installing DCS301B51. (19) The BYFQ60C4* R-32 panels can be connected to R-410A indoor units with wire harness EKRS22.
(14) Wire harnass EKEWTSC is necessary. (20) Wire harness EKRS23 is necessary.
(15) The active airflow circulation function is not available for this controller.

21
Technical drawings

Outdoor units
RXYSA-AV1/AY1 23

FXFA-A 27

FXZA-A 29

FXDA-A 30

FXSA-A 32

FXAA-A 35

22
RXYSA-AV1/AY1
171 758 171

30
(480~490)
485

460
55
36
41

30
4 holes for anchor bolts 101
M12

4 3
40 1100

7
7 51 45
6
869

6
5
5

325
45

45
190
95

95

95
175
26

90 25 25 90 12 99

53
70

53

70

53
150 150

8
71 17
17

1 Gas pipe connection ·Ø22.2· brazing


58

2 Liquid pipe connection ·Ø9.5· brazing


103

3 Service port (in the unit)


5
4 Electronic connection and grounding terminal ·M5· (in the switch box)
246
59

5 Refrigerant piping intake


45 Knockout hole.
51
46

6
50
109 7 Knockout hole.
289 163 163 163 8 Drain outlet

RZA-D

250 250

Wall

*
For optimal serviceability, provide ≥·250·mm of free space.
For more installation and service space guidelines, see drawing ·3D069554·.

3D1209
23
RXYSA-AV1/AY1
RXYSA-AV1
RXYSA-AY1
Single unit ( ) | Single row of units ( )

Suction side
In the illustration below, the service space at the suction side is based on 35°C DB and cooling
operation. Foresee more space in the following cases:
- When the suction side temperature regularly exceeds this temperature.
- When the heat load of the outdoor units is expected to regularly exceed the maximum operating
capacity.
Discharge side
Take refrigerant piping work into account when positioning the units. If your lay
out does not match with any of the layouts below, contact your dealer.

Single unit ( ) |Single row of units ( )


(mm)
A~E Hb Hd Hu
a b c d e eB eD
B - ≥ 100

eB A,B,C
B,E
-
-
≥ 100(1) ≥ 100
≥ 100
≥ 100
≥ 1000 ≤500
eD A,B,C,E - ≥ 150(1) ≥ 150 ≥ 150 ≥ 1000 ≤500
D - ≥ 500
E e D,E - ≥ 500 ≥ 1000 ≤500
Hd>Hu ≥ 100 ≥ 500
C B H B,D
Hd≤Hu ≥ 100 ≥ 500

HD c HU B
Hb≤½Hu ≥ 250 ≥ 750 ≥ 1000 ≤500
b Hd>Hu ½Hu>Hb≤Hu ≥ 250 ≥ 1000 ≥ 1000 ≤500
D d a A B,D,E Hb>Hu
1
Hd≤½Hu ≥ 100 ≥ 1000 ≥ 1000 ≤500
Hd≤Hu ½Hu<Hd≤Hu ≥ 200 ≥ 1000 ≥ 1000 ≤500
Hd>Hu
eB A,B,C - ≥ 200(1) ≥ 300 ≥ 1000
A,B,C,E - ≥ 200(1) ≥ 300 ≥ 1000 ≥ 1000 ≤500
eD D - ≥ 1000

E e
D,E -
Hd>Hu ≥ 300
≥ 1000
≥ 1000
≥ 1000 ≤500

C B,D
Hd≤Hu
Hd≤½Hu ≥ 250 ≥ 1500

c HU ≥100(1)
B
½Hu<Hd≤Hu
Hb≤½Hu
≥ 300
≥ 300
≥ 1500
PATTERN 1
≥ 1000 ≥ 1000 ≤500
≥100(1) HB ≥ 300 ≥ 1250 ≥ 1000 ≤500
HD b B,D,E
Hd>Hu ½Hu<Hb≤Hu
Hb>Hu
D d Hd≤½Hu ≥ 250 ≥ 1500 ≥ 1000 ≤500
1+2

a A Hd≤Hu ½Hu<Hd≤Hu
Hd>Hu
≥ 300 ≥ 1500 ≥ 1000 ≤500

(1) For better serviceability, use a distance ≥250 mm


A,B,C,D Obstacles (walls/baffle plates)
E Obstacle (roof)
a,b,c,d,e Minimum service space between the unit and obstacles A, B, C, D and E
eB Maximum distance between the unit and the edge of obstacle E, in the direction of
obstacle B
eD Maximum distance between the unit and the edge of obstacle E, in the direction of
obstacle D
Hu Height of the unit
Hb,Hd Height of obstacles B and D
1 Seal the bottom of the installation frame to prevent discharged air from flowing back to
the suction side through the bottom of the unit.
2 Maximum two units can be installed.
Not allowed

24
1D128513
RXYSA-AV1/AY1
RXYSA-AV1
RXYSA-AY1
Multiple rows of units ( )

Multiple rows of units ( )

≥100(1)
≥100(1)

≥100 H
B

b
≥100(1)
≥2000
≥100(1)
≥3000

≥100(1)
≥200
≥100(1)
≥1000
H
U ≥ 600
≥1500

Hb Hu b (mm)
Hb≤½Hu b≥250
½Hu<Hb≤Hu b≥ 300
Hb>Hu

(1) For better serviceability, use a distance ≥250 mm


Not allowed

1D128513
25
RXYSA-AV1/AY1
RXYSA-AV1
RXYSA-AY1
Stacked units (max.2 levels) ( )

Stacked units (max.2 levels) ( )


A2

A1
≥100(1)

A2 ≥100(1)
≥500
A2
≥500
≥1000
≥300

B2
B1
≥100(1)

B2
≥100(1)
≥100(1)
B2

≥100(1)
≥1000
≥300

(1)For better serviceability, use a distance ≥250 mm


A1=>A2 (A1) If there is danger of drainage dripping and freezing between the upper and lower
units…
(A2) Then install a roof between the upper and lower units. Install the upper unit high
enough above the lower unit to prevent ice buildup at the upper unit's bottom plate.
B1=>B2 (B1) If there is no danger of drainage dripping and freezing between the upper and lower
units…
(B2) Then it is not required to install a roof, but seal the gap between the upper and lower
units to prevent discharged air from flowing back to the suction side through the bottom
of the unit.

1D128513
26
FXFA-A WITH STANDARD PANEL
FXFQ-B
Notes
1. Location of nameplate
The unit nameplate is located on the control box cover.
The decoration panel nameplate is located on the piping-side panel frame, under the corner cover.
2. When installing optional accessories, refer to their respective documentation.
3. Make sure the distance between the ceiling and the cassette does not exceed ·35·mm.
The maximum ceiling opening is ·910·mm.
4. When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥·10·mm)
5. When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit.
6. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller.
·300· or less 7 6
See note ·5·.
420
8
Drain side
DETAIL A DETAIL A
·2· places ·2· places
Opposite side Opposite side

See note ·3·.


Suspension position
67 96.5
9 A 54.5 54.5 96.5
53

80

80
860-910

950
780

100
100
25.4

25.4
213
Ceiling opening

121.5

121.5
350

350
100

100
Ø75

10

80

80
95
420 AB Piping side
See note ·6·. FCAG100/125/140BVEB
710
Suspension position
950
FCAHG71/100/125/140HVEB FCAG35/50/60/71BVEB
860-910 840
FXFQ80/100/125BVEB FXFQ20/25/32/40/50/63BVEB
Ceiling opening See note ·3·.
DETAIL B
Adjustable

55 840 55
340 DETAIL B
4 1 2 ·2· places ·2· places
3
0-675

Opposite
350
side Opposite side
2D121655
130

350
C
Required installation space

121.5 121.5

AA
175

150
10

110

96.5 54.5 54.5

95

53
67
B
·2700· or more

40

35 35 280 81 100 100 85

96.5
See note ·3·. 5 See note ·3·. 4 - M8 OR M10 330
81 100 100 85
Suspension bolt
FCAG100/125/140BVEB FCAG35/50/60/71BVEB
ARROW VIEW C FCAHG71/100/125/140HVEB FXFQ20/25/32/40/50/63BVEB
FXFQ80/100/125BVEB
Item Name
Respect the distances shown on the figure. ·1500· or more 1 Liquid pipe connection port
Ceiling-mounted lighting Air fan ·200· or more 2 Gas pipe connection port
Other unit
3 Drain pipe connection
·1500· or more ·1500· or more
4 Power supply wiring intake
·200· or more 5 Transmission wiring intake hole
·1500· or more
·1500· or more 6 Air discharge outlet
·2000· or more
·4000· or more
Required installation space 7 Air suction grille
8 Corner decoration cover
If a discharge outlet is closed up with the "sealin g member" option kit, then the required
installation space on that (closed up) side is ·500·mm instead of ·1500·mm. 9 Drain hose
10 Knockout hole. 2D121655

FXFA-A WITH AUTO CLEANING PANEL


FXFQ-B
FXFQ-B
Notes 1. Location of nameplate
The unit nameplate is located on the control box cover.
Notes 1. Location of nameplate
The decoration panel nameplate
The unit nameplate is locatedis located on the box
on the control piping-side
cover. panel frame, under the corner cover.
2. When
The installing
decoration optional accessories,isrefer
panel nameplate to their
located respective
on the documentation.
piping-side panel frame, under the corner cover.
3. Make sure the
2. When distanceoptional
installing between the ceilingrefer
accessories, and to
thetheir
cassette does not
respective exceed ·35·mm.
documentation.
The maximum ceiling
3. Make sure opening between
the distance is ·910·mm. the ceiling and the cassette does not exceed ·35·mm.
4. When the conditions in the ceiling exceed
The maximum ceiling opening is ·910·mm. 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥·10·mm).
5. When installing
4. When a sensor kit,inthere
the conditions will beexceed
the ceiling a sensor
30°Con ambient
this location. For details,
temperature and see therelative
80% drawing of the sensor
humidity, kit. fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥·10·mm).
or when
5. When installing
·300· or lessa sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit. See note ·5·. 7 6 8 Drain side
420
·300· or less See note ·5·. 7 6 8 Drain side
420
See note ·3·.

DETAIL A DETAIL A
See note ·3·.
Suspension position

·2· places
9 A ·2· placesDETAIL A DETAIL A
Suspension position

9 ·2· places
Opposite side
A Opposite side
·2· places 67 96.5
860-910

53Opposite side
950

54.554.5 96.5
780

Opposite side 67 96.5


860-910

53
950

54.554.5 96.5
780

213

80

80
Ceiling opening

213

100 80

80
Ceiling opening

Ø75
350 25.4

100
350 25.4
100
121.5

121.5
350

75
350
25.4

100
25.4

10 Ø
121.5

121.5
100

100

10
100

100

420 AB
80

Piping side
80

710 AB
420 950
80

Suspension position Piping side


80

710 95
860-910position
Suspension 950
DETAIL B
Adjustable

Ceiling opening See note ·3·. 840 FCAG100/125/140BVEB


95
FCAG35/50/60/71BVEB
860-910
340 DETAIL B
·2· places FCAHG71/100/125/140HVEB FXFQ20/25/32/40/50/63BVEB
Adjustable

840
0-675

55 840
Ceiling opening See note55
·3·. 4 1 2 FCAG100/125/140BVEB
FXFQ80/100/125BVEB FCAG35/50/60/71BVEB
3 340 ·2· places
Opposite side FCAHG71/100/125/140HVEB FXFQ20/25/32/40/50/63BVEB
0-675

55 840 55
210

4 1 2 FXFQ80/100/125BVEB
3 350
Opposite
121.5 side
210
Required installation space

350
AA
255

121.5
Required installation space

54.5
AA

190 230
255

190

95

B
96.5 54.5
90

54.5

C
230
·2700· or more

95

B
96.5 54.5
90

C 4 - M8 OR M10 280 81 100 100 85


40

35 5
·2700· or more

35 330
Suspension bolt 280 81 100 100 85
See note
35 ·3·. See note ·3·. 4 - M8 OR M10
40

5 35
See note ·3·. See note ·3·.
ARROW VIEW C 330
Suspension bolt FCAG100/125/140BVEB
·1500· or more
ARROW VIEW C FCAHG71/100/125/140HVEB
FCAG100/125/140BVEB
FXFQ80/100/125BVEB
·200· or more ·1500· or more FCAHG71/100/125/140HVEB
FXFQ80/100/125BVEB
·200· or more
·1500· or more ·1500· or more
Ceiling-mounted lighting
Air fan Other unit
Ceiling-mounted lighting ·1500· or more
·200· or more
·1500· or more DETAIL B Item Name
Air fan Other unit
·200· or more
·1500· or more DETAIL B
·2· places 1 Item Name
Liquid pipe connection port
(*2) (*3) (*1) ·1500· orspace
more Opposite side
·2· places 2
Required installation 1Gas pipe connection
Liquid port port
pipe connection
(*2) 256 (*3) (*1) If a discharge outlet is closed up with the "sealing member" option kit, then the required 350
Opposite side 3
Required installation space 121.5 2DrainGas
pipepipe
connection
connection port
256 ·1500· or more installation space on that (closed up) side is ·500·mm instead of ·1500·mm. 350 4 Power supply wiring intake
If a discharge outlet is closed up with the "sealing member" option kit, then the required 3 Drain pipe connection
·2000· or more Dust(closed
opening 121.5 5
7

·1500· or more installation space on that up) side is ·500·mm instead of ·1500·mm. 4Transmission wiringwiring
Power supply intakeintake
hole
·4000·
·2000· or more
or more Dust opening 6 5Air discharge outletwiring intake hole
53
96.5 67
53 7

Transmission
10° 10° 7 6Air suction grille outlet
Air discharge
·4000· or more
96.5 67

81 100 100 85 8
10° 10° 7Corner
Airdecoration cover
suction grille
Piping 81 100 100 85 9 8DrainCorner
hose decoration cover
Piping 10 9Knockout hole.
Drain hose
Piping FCAG35/50/60/71BVEB
(*1)Not applicable to recessed lighting. Piping FXFQ20/25/32/40/50/63BVEB 10 Knockout hole.
FCAG35/50/60/71BVEB
(*2)Required
(*3)Make
space for entering
(*1)Not applicable
sure the decoration
withlighting.
to recessed vacuum cleaner tube.
panel discharge outlet is not tube.
blocked. Air suction grille FXFQ20/25/32/40/50/63BVEB 2D121658
(*2)Required space for entering with vacuum cleaner
(*3)Make sure the decoration panel discharge outlet is not blocked. Installation direction
Air suction grille 2D121658
Installation direction
27
FXFA-A WITH DESIGNER PANEL
FXFQ-B
Notes
1. Location of nameplate
The unit nameplate is located on the control box cover.
The decoration panel nameplate is located on the piping-side panel frame, under the corner cover.
2. When installing optional accessories, refer to thei r respective documentation.
3. Make sure the distance between the ceiling and the cassette does not exceed ·35·mm.
The maximum ceiling opening is ·910·mm.
4. When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥·10·mm).
5. When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit.
6. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller.
·300· or less 7 6
See note ·5·. 8
420 Drain side

DETAIL A DETAIL A
·2· places ·2· places
Opposite side Opposite side

See note ·3·.


Suspension position
67 96.5
53
9 A 54.554.5 96.5

860-910

80

80
950
780

25.4

100
25.4
100
213
Ceiling opening

121.5

121.5
350

350
100

100
Ø75
10

80

80
95
420 AB
Piping side FCAG35/50/60/71BVEB
710 See note ·6·. 950 FCAG100/125/140BVEB FXFQ20/25/32/40/50/63BVEB
Suspension position FCAHG71/100/125/140HVEB
860-910 FXFQ80/100/125BVEB
See note ·3·. 840
Ceiling opening DETAIL B
Adjustable

55 840 55 340 DETAIL B


4 1 2 ·2· places ·2· places
B 3
0-675

Opposite side Opposite side


172

350 350
C
Required installation space

121.5 121.5

AA
52
217

152
192

96.5 54.554.5

95

53
67
·2700· or more

35 35 280 81 100 100 85


45

96.5
5 81 100 100 85
4 - M8 ORM10 330
See note ·3·. See note ·3·. Suspension bolt
FCAG100/125/140BVEB FCAG35/50/60/71BVEB
ARROW VIEW C FCAHG71/100/125/140HVEB FXFQ20/25/32/40/50/63BVEB
FXFQ80/100/125BVEB

Item Name
Respect the distances shown on the figure. ·1500· or more 1 Liquid pipe connection port
Ceiling-mounted lighting ·200· or more 2 Gas pipe connection port
Air fan Other unit
3 Drain pipe connection
·1500· or more ·1500· or more 4 Power supply wiring intake
5 Transmission wiring intake hole
·1500· or more ·200· or more 6 Air discharge outlet
·1500· or more 7 Flat grille assembly
·2000· or more
Corner decoration cover
Required installation space
8
·4000· or more
9 Drain hose
10 Knockout hole.
If a discharge outlet is closed up with the "sealing member" option kit, then the required
installation space on that (closed up) side is ·500·mm instead of ·1500·mm.
2D121703

FXFA-A WITH FRESH AIR INTAKE


FXFQ-B AA AB Model name
FCAG35/50/60/71BVEB
264 306
FXFQ20/25/32/40/50/63BVEB
55 840 55 Duct FCAG100/125/140BVEB
306 348
Left side FXFQ80/100BVEB
Piping side FCAHG71/100/125/140HVEB
348 390
FXFQ125BVEB
See note ·3·.
427
328

140
Static pressure in chamber [Pa]

130
120
840

110
100
328

90
427

80
70
See note ·3·.
Drain side 60
50
40
30
448 Duct View ·A· 20
Service access panel (1000) 10
508 Right side ·450 x 450 mm· or more
Ø148

0 2 1 4 5 3 6
See note ·1·. Air flow rate [m³/min]
AA

275
165

Suction chamber 455 T-joint


Ceiling opening Field supply
Decoration panel
Ø148

725
A Inlet
AB

317
207

Notes
455
Suction chamber
1. When installing a fresh air intake kit, provide a service access panel. Designer decoration panel
2. Field construction Ceiling opening
3. This corner discharge outlet needs to be closed.
4. When installing a duct fan, use a wiring adapter to link the duct fan to the fan of the indoor unit.
5. The intake air flow rate is recommended to be ≤20% of the air flow rate at high fan speed.
If the intake air flow rate is too large, the operating sound may increase, and the detection of the indoor unit suction temperature may be affected.
6. This indicates the distance between the T-joint inlet and the indoor unit inlet when the T-tube is connected.
3D121741
28
FXZA-A
FXZQ-A
Decoration panel
585-595 (Ceiling opening space)
BYFQ60C2W1W Fresh white N9.5
BYFQ60C2W1S Daikin Silver 300 or less 533 (Suspension position)

Service access panel


Pipe connection side 450x450mm or more

585-595 (Ceiling opening space)


533 (Suspension position)
4-M4 Hole
Outdoor air intake
(direct connection)

B Arrow view
Drain connection side

• Required space
A Arrow view Note) 2. 1500 mm or more

1500 mm or more
1500 mm or more

1500 mm or more

When the discharge grill is closed, the required space


Adjustable (0-630)

is 200mm or more

C Arrow view

1 Liquid piping connection ø 6.4 Flare connection

300 mm or more
2 Gas piping connection ø 12.7 Flare connection
3 Drain piping connection VP20 (O.D. ø 26)
4 Power supply connection
5 Remote control code and
wiring connection
6 Air discharge grille

From the floor 2500 or more


7 Suction grill

For height installation


10 or less

1500 mm or more
10 or less
Suspension bolt 8 Drain hose (accessory) I.D. ø 25 Outlet

Required space
Note ) 4.

Notes:

1. Sticking locations for manufacturer`s label


Manufacturer`s label for indoor unit: on the bell mouth inside suction grille.
Manufacturer`s label for decoration panel: on the inner frame inside suction grille.
2. In case of using infrared remote controller, this position will be a signal receiver. Refer tot the drawing of infrared remote controller in detail.
3. When the temperature and humidity in the ceiling exceed 30ºC and RH 80%, or the fresh air is inducted into the ceiling or the unit continues
24 hour operation, an additional insulation (thickness 10mm or more, Glasswool or polyethylene foam) is required.
4. Though the installation is acceptable up to maximum of 595mm square ceiling opening, keep the clearance of 10mm or less between the
main unit and the ceiling opening so that the panel overlap allowance can be ensured. 3D082052

FXZA-A

Decoration panel
585-660 (Ceiling opening space)

300 or less 533 (Suspension posotion)

Pipe connection side Service access panel


450x450mm or more
585-660 (Ceiling opening space)
533 (Suspension posotion)

4-M4 Hole
Outdoor air intake
(direct connection)

B Arrow view

Drain connection side


• Required space
1500 mm or more
Note) 2. A Arrow view

1500 mm or more
1500 mm or more

1500 mm or more

When the discharge grill is closed, the required space


Adjustable (0-645)

is 200mm or more

C Arrow view 1 Liquid piping connection ø 6.4 Flare connection


2 Gas piping connection ø 12.7 Flare connection
3 Drain piping connection VP20 (O.D. ø 26)
4 Power supply connection
295 mm or more

5 Remote control code and


wiring connection
6 Air discharge grille
7 Suction grill
8 Drain hose (accessory) I.D. ø 25 Outlet

45 or less 45 or less
Required space

For height installation


1500 mm or more

From the floor 2500

Suspension bolt Note ) 4.


or more

Notes:

1. Sticking locations for manufacturer’s label


Manufacturer’s label for indoor unit: on the bell mouth inside suction grille.
Manufacturer’s label for decoration panel: on the inner frame inside suction grille.
2. In case of using infrared remote controller, this position will be a signal receiver. Refer tot the drawing of infrared remote controller in detail.
3. When the temperature and humidity in the ceiling exceed 30ºC and RH 80%, or the fresh air is inducted into the ceiling or the unit continues
24 hour operation, an additional insulation (thickness 10mm or more, Glasswool or polyethylene foam) is required.
4. Though the installation is acceptable up to maximum of 660mm square ceiling opening, keep the clearance of 45 mm or less between the
main unit and the ceiling opening so that the panel overlap allowance can be ensured. 3D082161A

29
FXDA10-32A
FXDQ15-32A
300 or more 300 or more
(Service space of (Service space)
installation box for
adapter PCB)

240 or more
20 or more
400 or more
(In case of
bottom-suction)

(Suspension bolt pitch)

20 or more
Ceiling

Service space
16x ø 4,7 holes

View A
(Suspension bolt pitch) 300 or more Inspection door (ceiling opening)

Adjustable (0-600)
Suspension bolt

16xM5 holes

14xM4 holes

In case of back suction

Notes:
1 Liquid pipe connection ø 6.4 Flare connection
2 Gas pipe connection ø 12.7 Flare connection 1. In case of back-suction, mount chamber cover to
3 Drain pipe connection VP20 (O.D. ø 26, I.D. ø 20)
4 Drain hose (accesory) ID ø 25 (Outlet)
botttom side of the unit.
5 control box In case of bottom-suction, mount chamber cover to
6 Transmisiion wiring connection back side of the unit.
7 Power supply connection
2. Locations of unit`s name plate: control box cover.
8 Suspension bracket
9 Inspection cover 3. Mount the air filter at the suction side. (Use an air filter
16xM5 holes
10 Socket for drain whose dust collecting efficiency is at least 50% in a
11 Air filter (accessory) gravimetric technique). It can not be equipped with air
In case of bottom-suction
filter (accessory) when connecting duct to suction side.

3D081435

FXDA40-50A

FXDQ40-50A
300 or more 300 or more
(Service space of (Service space)
installation box for
20 or more

adapter PCB) 400 or more


240 or more

(In case of
bottom-suction)
20 or more
(Suspension bolt pitch)

Ceiling

Service space

22 x ø 4,7 hole
Adjustable (0-600)

(Suspension bolt pitch) View A


Inspection door (ceiling opening)
300 or less
Suspension bolt

20xM5 holes

18xM4 holes

In case of back suction

20xM5 holes
Notes:

1 Liquid pipe connection ø 6.4 Flare connection 1. In case of back-suction, mount chamber cover to
2 Gas pipe connection ø 12.7 Flare connection botttom side of the unit.
3 Drain pipe connection VP20 (O.D. ø 26, I.D. ø 20)
4 Drain hose (accesory) ID ø 25 (Outlet)
In case of bottom-suction, mount chamber cover to
5 control box back side of the unit.
6 Transmission wiring connection 2. Locations of unit`s name plate: control box cover.
7 Power supply connection
8 Suspension bracket
3. Mount the air filter at the suction side. (Use an air filter
In case of bottom-suction 9 Inspection cover whose dust collecting efficiency is at least 50% in a
10 Socket for drain gravimetric technique). It can not be equipped with air
11 Air filter (accessory)
filter (accessory) when connecting duct to suction side.

30 3D081436
FXDA63A
300 or more 300 or more
(Service space of installation box for adapter PCB) (Service space)

400 or more

240 or more
20 or more
(Suspension bolt pitch)
(in case of bottom suction)

20 or more
Ceiling
26 x dia. 4.7 holes

Service space
(Suspension bolt pitch) View A
Inspection door (ceiling opening)
300 or less
24x M5 holes

Adjustable (0~600)
Suspension bolt
4x m8 ~ m10

Notes : In case of back suction


1. In case of back suction, mount chamber cover to bottom side of the unit.

In case of bottom suction, mount chamber cover to back side of the unit.

2. Location of unit name plate: control box cover.


3. Mount the air filter at the suction side.
(use an air filter whose dust collecting efficiency is at least 50%in a gravimetric technique).

24x M5 holes
It can not be equipped with air filter (accessory) when connecting duct to suction side

Item Name Description


Liquid pipe connection Dia.9.5 flare connection
Gas pipe connection Dia.15.9 flare connection
Drain pipe connection VP20 (OD dia.26, ID dia.20)
Drain hose (accessory) ID dia.25 (outlet)
Control box
In case of bottom suction Transmission wiring connection
Power supply connection
Suspension bracket
Inspection cover
Socket for drain
Air filter (accessory)

31
FXSQ15-32A
FXSA15-32A

170 Ø100 Suspension bolt 550 69 25 800


(Knockout hole.)

Service space
300 or more
342 40 301
Fresh air intake position KJ KH
KC KE

2x65=130
50

109
100
65

38
140

178

110

210
245
ARROW VIEW A
KK
2x140=280 32

50
126 P.C.D. KF 179.2 50 KD
4-M4 (CLASS 2) 365 500 or more
Service space
504
588 Suspension position 145 150 145
4x65=260

210
KA

95
Suspension position KB

ARROW VIEW A KG
630

Item Name Description


KA Liquid pipe connection port Ø6.35 flared connection
KB Gas pipe connection port Ø12.70 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side /
KJ Air discharge side / Notes
1. When installing optional accessories, refer to their respective documentation.
KK Nameplate / 2. The ceiling depth varies according to the documentation of the specific system. 3D094888A

FXSA40-50A
XSQ40-50A

170 Ø100 Suspension bolt 700 69

Service space
(Knockout hole. ) 25 800
300 or more
492 40
301
2x65=130

Fresh air intake position


50 KJ KC KE KH
109
100
65

38
140

178
245

110
210

ARROW VIEW A
KK
126 P.C.D. 3x140=420 32 KF 179 50
50

KD
515 500 or more
4-M4 (CLASS 2)
Service space 654
4x145=590
738 Suspension position

6x65=390

KA
210
95

KB
Suspension position

ARROW VIEW A KG
630

42 155 130 130 120 5- Ø 4.7 HOLE

Item Name Description


KA Liquid pipe connection port Ø6.35 flared connection
KB Gas pipe connection port Ø12.70 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side /
Notes
KJ Air discharge side /
KK Nameplate /
1. When installing optional accessories, refer to their respective documentation.
2. The ceiling depth varies according to the documentation of the specific system.
3D094919A

32
FXSQ63-80A
FXSA63-80A

170 Ø 100 Suspension bolt 1000 69 25 800


(Knockout hole. )

Service space
792 40

300 or more
301

2x65=130
Fresh air intake position 50 KC KE KH
KJ

109
38
100
65
140

178

110
210
245
ARROW VIEW A
KK

50
126 P.C.D. 5x146=730 32 179 50
KF KD
4 x M4 (CLASS 2) 815 500 or more
Service space

954
1038 Suspension position
6x145=890
11x65=715

210
95
KA

KB
ARROW VIEW A
630Suspension position

KG KG

42 135 125 98 117 135 125 100 8- Ø 4.7 HOLE

Item Name Description


KA Liquid pipe connection port Ø9.52 flared connection
KB Gas pipe connection port Ø15.90 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side /
Notes
KJ Air discharge side / 1. When installing optional accessories, refer to their respective documentation.
KK Nameplate / 2. The ceiling depth varies according to the documentation of the specific system.

3D094916A

FXSQ100-125A
FXSA100-125A

170 Ø100 Suspension bolt 1400 69 25 800

Service space
(Knockout hole. )

300 or more
1192 40 301
KC
2x65=130

Fresh air intake position KJ KE KH


50
109
38
100
65
140

178

110
210
245

ARROW VIEW A
KK
126 P.C.D. 7x156=1092 32 179 50
50

KF
1215 500 or more KD
4 x M4 (CLASS 2)
Service space

1354
1438 Suspension position 8X150=1200
16x65=1040
226
95

KA

KB KG
KG ARROW VIEW A
630Suspension position

42 150 147.5 147.5 115 115 150 147.5 147.5 115 10x Ø 4.7 HOLE

Item Name Description


KA Liquid pipe connection port Ø9.52 flared connection
KB Gas pipe connection port Ø15.90 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side / Notes
KJ Air discharge side / 1. When installing optional accessories, refer to their respective documentation.

KK Nameplate / 2. The ceiling depth varies according to the documentation of the specific system. 3D094917A

33
FXSQ140A
FXSA140A

Ø100
(Knockout hole. )
Suspension bolt 1550 69 25 800

Service space
170

300 or more
Fresh air intake position
1342 40

2x65=130
301
50 KC KE

109
KJ KH

62
100

38
65
140

178
245

110
210
ARROW VIEW A
KK
126 P.C.D. 8x156=1248 32

50
KF 179 50 KD
1365 500 or more
4 x M4 (CLASS 2) Service space
1504
9x150=1350
1588 Suspension position

60 18x65=1170 60

210
95
KA

KB
KG ARROW VIEW A KG
630 Suspension position

42 151 123 122 123 116 115 151 123 122 123 116 10x Ø4.7 HOLE

Item Name Description


KA Liquid pipe connection port Ø9.52 flared connection
KB Gas pipe connection port Ø15.90 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side /
Notes
KJ Air discharge side / 1. When installing optional accessories, refer to their respective documentation.
KK Nameplate / 2. The ceiling depth varies according to the documentation of the specific system. 3D094928A

34
FXAA15-32A
FXAQ15-32A

Hole for piping Hole for piping

Required space
90 or more
Hole for piping Hole for piping
About 365
Drain hose
About 420
Gas pipe
About 460
Liquid pipe

Required space
Dimensions of fully opened front panel

30 or more
450

Indoor air flow


266 Knockout hole.

2500 or more
Front grille fixing screws 120 or less
Location of nameplate

For installation in high places


290

Front panel
Air outlet
Horizontal blade
Front grille Hole for piping Hole for piping
50 or more 795 50 or more
Knockout hole. Required space Required space
Standard location of holes in the wall
Blade angle 107.6 625 62
14

Up/down (automatic)
Cooling Outer dimensions of the unit
Heating Fan
Dry
Refrigerant filter
4° Hole for embedded piping
12° Hole for embedded piping
19°
16°
27°
55°
25° 42°  0
8

105
50° 64° 80
58°
44

57°
Left/right (manual)
About 290
60 Flexible pipe
About 308 98

44
Flexible pipe
45° ° About 415
45 Gas pipe
Ø 12.7mm CuT
About 460
Liquid pipe
Notes Ø 6.4mm CuT
1) The mark shows the piping direction. About 475
Drain hose VP13
2) Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain
outlets, or dirty air filters, condensate may drop out. Inside diameter: 15mm
3D111370
Outside diameter: 18mm
29

FXAQ40-50A
FXAA40-50A

Hole for piping Hole for piping Required space


90 or more

About 365 Hole for piping


Drain hose Hole for piping
About 420
Gas pipe
About 460
Liquid pipe
Required space

Dimensions of fully opened front panel


30 or more

450
Indoor air flow
Location of nameplate
Knockout hole.
269
2500 or more

Front grille fixing screws 120 or less

For installation in high places


290

Front panel Air outlet


Horizontal blade
Front grille
Hole for piping Hole for piping
50 or more 1050 50 or more
Knockout hole. Required space
Required space
Blade angle Standard location of holes in the wall
14.5

104 894 52
Up/down (automatic)
Cooling
Heating Fan
Dry Outer dimensions of the unit


12°
Hole for embedded piping
19°
16°
27° 25° 42°  Refrigerant filter
0
8
55°
105

50° 64° 80
58°
44

57°
Left/right (manual)
About 290
44

60 Flexible pipe
About 300 98
Hole for embedded piping Flexible pipe
45° ° About 415
45
Gas pipe
Ø 12.7mm CuT
About 460
Liquid pipe
Ø 6.4mm CuT
Notes About 475
Drain hose VP13
1) The mark shows the piping direction.
Inside diameter: 15mm
2) Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outl
ets, or dirty air filters, condensate may drop out. 3D111369
Outside diameter: 18mm

35
FXAA63A
FXAQ63A
Hole for piping Hole for piping

Required space
90 or more
About 365
Drain hose Hole for piping Hole for piping
About 420
Gas pipe
About 460
Liquid pipe

Required space
Dimensions of fully opened front panel

30 or more
Indoor air flow
Location of nameplate Knockout hole

2500 or more
Front grille fixing screws 120 or less

For installation in high places

Front panel Horizontal blade Air outlet


Front grille Hole for piping Hole for piping
50 or more 50 or more
Knockout hole Required space Required space
Blade angle Standard location of holes in the wall
Up/down (automatic) Outer dimensions of the unit
Cooling
Dry Heating Fan HOLE FOR CONCRETE WALL HOLE FOR CONCRETE WALL

125mm TO UNIT USE TAPE MEASURE AS SHOWN UNIT WIDTH: 1050 mm


UNIT HEIGHT: 290 mm
LEFT PLACE A LEVEL
SIDE FACE
100mm TO
TO UNIT OUTLINE UNIT RIGHT
525mm TO THE RIGHT AND LEFT SIDE FACE

Hole for embedded piping


Position the end of 145mm UP AND DOWN
tape measure at PIPING HOLE CENTER: 90 mm DOWN
unit center

Liquid pipe end Gas pipe end

PIPING HOLE CENTER


83mm TO THE LEFT
Refrigerant filter IF FIXING
UNIT TO
THIS PLATE
WITH SCREW
FIX THIS
PLATE TO
THE WALL
PIPING HOLE
CENTER
100mm TO
THE RIGHT

WITH SCREW

Left/right (manual) About 290


Flexible pipe
About 300
Hole for embedded piping Flexible pipe
About 415
Gas pipe
ø 15.9mm CuT
About 460
Liquid pipe
ø 9.5mm CuT
About 475
Drain hose VP13
Inside diameter: 15 mm
NOTES Outside diameter: 18 mm

1. The mark shows the piping direction.


2. Do not place any objects under the indoor unit. In case of high humidity
(>80%), clogged drain outlets or dirty air filters, condensate may drop out.
3D111368

36
Definitely the best VRV
we ever made
37
Notes

38
39
Creating
a sustainable
future together

Determined to reduce our environmental footprint, we aim to be CO₂-neutral by 2050.


A circular economy, innovation and smart use – these are the stepping stones on our path.
The time to act is now. Join us in creating a sustainable future for HVAC-R.

Sowing the seeds of climate protection with Daikin

Through a circular economy Through innovation Through smart use


› Embrace Certified Reclaimed Refrigerant › Equip our VRV 5 range with › Rigorously follow up on energy consumption
Allocation to reuse more refrigerant the lower GWP refrigerant R-32 via the Daikin Cloud Service
› Increase recovered refrigerant returns › Offer high real-world seasonal efficiencies › Factor in experts’ advice to continuously
› Reuse refrigerant for maintenance with › Deploy unique auto cleaning filters optimise system efficiency
our refrigerant recycling machine to maximise efficiency 24/7 › Enable predictive maintenance to ensure
optimum operation and uptime
› Prevent energy waste with smart key cards
and sensors
www.daikin.eu/building-a-circular-economy
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Publisher)

The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has
FSC compiled the content of this publication to the best of its knowledge. No express
or implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
ECPEN20 -210C 01/2021 therein. Specifications are subject to change without prior notice. Daikin Europe
N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of this publication.