Professional Documents
Culture Documents
35-10-25 30.07.2011 Revision6
35-10-25 30.07.2011 Revision6
PNR E28180-SERIES
AND
BRACKETS
PNR E28095-02
PNR E28183-04
PNR E28292-00
PNR E28331-03
TP Page 1/2
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
TP Page 2/2
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
HIGHLIGHT
PARTNUMBER: E28180-SERIES
DUE TO THE EXTEND OF THE CHANGES INVOLVED IN THIS REVISION, THIS PUBLICATION HAS
BEEN REPRINTED IN ITS ENTIRETY.
PLEASE REPLACE ALL MANUALS OF PRIOR ISSUES WITH THIS REVISION NO. 5 DATED JUL 30/11.
HL Page 1/2
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
HL Page 2/2
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
RECORD OF REVISIONS
LEP Page 1
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
LEP Page 2
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
TABLE OF CONTENTS
SUBJECT PAGE
INTRODUCTION 1
General Information INTRO-1
Manual Guidelines INTRO-1
Abbreviations Used INTRO-1
Revision INTRO-2
Shop Verification INTRO-2
Manufacturing INTRO-2
DESCRIPTION AND OPERATION 1
General 1
Technical Data 1
Identification 1
Description 2
Operation 5
TESTING AND FAULT ISOLATION 101
General 101
Test Equipment 101
Functional Test 102
Fault Isolation 102
AUTOMATIC TEST REQUIREMENTS N/A
DISASSEMBLY 301
General 301
Procedure 301
CLEANING 401
Equipment and Materials 401
Procedure 401
TOC Page 1
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
CHECK 501
General 501
Procedure 501
PAGE
REPAIR 601
Equipment and Materials 601
Replacement of the orange Self-Adhesive
Protection Tape of the Foil Bag 601
Replacement of the Serviceability Indicator 602
Discard of the Foil Bag (Smoke Hood) 604
ASSEMBLY 701
Equipment and Materials 701
Procedure 701
Storage Packaging and Transport 705
FITS AND CLEARANCES N/A
SPECIAL TOOLS, FIXTURES AND EQUIPMENT N/A
ILLUSTRATED PARTS LIST - INTRODUCTION 1001-1
General 1001-1
Material Arrangement 1001-1
How to Use the Illustrated Parts List 1001-4
List of Abbreviations 1001-4
List of Vendors 1001-5
Alpha Numerical Index 1001-6
DETAILED PARTS LIST 1001
TOC Page 2
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
INTRODUCTION
1. General
The Component Maintenance Manual obeys the ATA 100 STD (AIR TRANSPORT ASSOCIATION
AMERICA) revision 26 (AECMA simplified English).
This manual gives the procedures tested by the manufacturer in the workshop. Thus an approved tech-
nician who does not know the equipment can repair it and do a full overhaul on it.
The manual does not include the standard usual procedures, the frequency of the repairs and the proce-
dures which agree with the tools available in the maintenance workshop.
2. Manual Guidelines
INTRO Page 1
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
3. Abbreviations Used
A. Units
All the values are given in the international system (meter, kilogram, second) unit (or unit multiples). But it
can occur that the most used unit is given.
4. Revision
When there is a change, each updating shows the detailed instructions about the page number of the
pages which must be replaced, added or removed.
5. Shop Verification
6. Manufacturing
The Protective Breathing Equipment OXYCREW PNR E28180-Series is manufactured and product sup-
ported by:
INTRO Page 2
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
2. Technical Data
A. Ambient Conditions
Ground Survival
Temperatures -55 °C (-67 °F)
+40 °C (104 °F) for long term storage
+85 °C (185 °F) for maximum 3 hours
Pressure 572 hPa to 1199 hPa
Relative humidity 10 % to 95 %
Operation
Temperatures -18 °C (-40 °F)
+55 °C (131 °F)
+100 °C (212 °F) for 2 minutes
Pressure: 375 hPa (25.000 ft.) maximum
Relative humidity 10 % to 95 %
B. Performance
Operating time if user
is physically active: > 15 minutes
C. Parameter
Capacity of breathing bag 6L
D. Weight
PBE 2,50 kg (5.512 lb)
BRACKETS 0,30 kg (0.661 lb) (E28095-02/E28292-00)
0.39 kg (0.860 lb) (E28183-04)
0.27 kg (0.600 lb) (E28331-03)
E. Dimensions
Height x Width x Depth
Mod-Codes 0001/0002
[mm] [in.]
PBE 250 (9.842) x 200 (7.874) x 100 (3.937)
BRACKETS 262 (10.315) x 228 (8.976) x 30 (1.18)
262 (10.315) x 228 (8.976) x 25 (0.984) E28183-04 only
Page 1
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
NOTE: Life Time Extension is not applicable to units not modified according to Service
Bulletin No 001, dated January 29th, 1990.
It is assumed that all units concerned by this action have been modified accordingly
or removed from service.
FIGURE 1A
3. Identification
- Part Number,
- Manufacturers Name,
- Description of Equipment,
- Serial Number,
- Date of Assembly or Test,
- Inspection Stamp.
(1) The OXYCREW is a smoke hood, vacuum-packed in a foil and covered by light-weight container.
(2) The box assembly consists of a box with a hinged top cover. It is equipped with an inspection win-
dow to see the serviceability indicator of the smoke hood.
(3) The smoke hood is packaged into a vacuum foil bag (referred as to the foil bag). A cord with a ser-
viceability indicator is featured around the bag. It shows the serviceable condition of the foil bag
(smoke hood).
The vacuum foil bag is attached to the box by two plastic attachment strips and locking clamps.
(4) The smoke hood contains (Ref. to Fig. 3)
- a fire-resistant hood with a breathing bag protection,
- an inner mask,
- a breathing bag with a volume-controlled relief outlet valve and a KO2 cartridge with a starter.
The KO2 cartridge is connected to the inner mask by a flexible hose.
(5) The hood contains
- a fire-resistant visor with a sound-outlet opening,
- a neck seal and body belts,
- a relief valve in the hood lets the air out of the inner of the smoke coat.
(6) The inner mask consists of:
- a hard shell with a soft face piece. The face piece has a safety relief valve against suffocation,
- a sound outlet to speak that contains a voice transmitter and a megaphone connector.
- The hard shell is connected to the volume-controlled relief outlet valve of the breathing bag by
tube. The openings in the hard shell are to flush the visor with air. The hard shell and inner
Page 3
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
mask are attached to the hoods visor by the voice transmitter and the megaphone connector.
The head straps are attached to the hard shell and connected with the hood.
5. Operation
(1) The OXYCREW is a self contained device that contains a supply of breathable gas.
(2) This supply of breathable gas is given by a closed circuit of breathe. That has the function to re-
make the expired air and to add with oxygen, to get breathable again.
(3) The oxygen is made by an exothermic chemical effect. The potassium superoxide (KO2) of the car-
tridge effects with the carbon dioxide (CO2) and the humidity of the expired air.
6. Stowage
OXYCREW normally is stowed within a bracket. Various bracket types are available. The bracket is ei-
ther equipped with two metal bands or a clamping belt.
NOTE: When using a bracket with holding strap, use caution to pass the strap below the
upper handle (Ref. to Fig. 2).
Otherwise the handle could be damaged.
Page 4
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
SMOKE HOOD
FIGURE 3
Page 5
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 6
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
1. Testing
WARNING: STRICTLY OBEY THE PROCEDURES FOR THE USE OF OXYGEN EQUIPMENT. DO
NOT USE ANY OIL, GREASE OR OTHER PETROL BASED LUBRICANTS ON THIS
OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE HAZARD.
A. General
(1) Do an external visual check and clean if necessary, before continue with the operational test
and fault isolation procedure.
(2) Do all tests on standard ambient test laboratory conditions as follows:
- Temperature: 21° C (70° F)
- Relative humidity: max. 85 %
- Ambient pressure: 760 mm Hg (101,3 kPa)
B. Test Equipment
TEST EQUIPMENT
TABLE 1
Page 101
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
C. Functional Test
NOTE: Do this test only if the serviceability indicator of the smoke hoods vacuum
foil bag (Referred to as the foil bag) is damaged or broken.
The bag must be weighed together with the serviceability indicator and its
cord.
(a) Remove the foil bag from the box assy as specified in -DISASSEMBLY-.
(c) Put the foil bag together with the damaged/broken serviceability indicator on the balance
(Ref. to Table 1).
(d) Compare the weight shown on the foil bag with the weight indication on the balance. The
value shown on the balance must not more differ than 2,5 g (0.00551 lb).
(e) Replace the OXYCREW if the weight of the foil bag is out of the limit.
2. Fault Isolation
FAULT ISOLATION
TABLE 2
Page 102
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
DISASSEMBLY
WARNING: STRICTLY OBEY THE PROCEDURES FOR THE USE OF OXYGEN EQUIPMENT. DO
NOT USE ANY OIL, GREASE OR OTHER LUBRICANTS MADE FROM PETROL ON
THIS OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE HAZARD.
NOTE: Refer to TESTING AND FAULTISOLATION and CHECK to find out the condition or
the malfunction of the OXYCREW.
NOTE: Refer to the ILLUSTRATED PARTS LIST for Item numbers.
(b) Remove the locking clamp (Ref. to IPL-Fig.2, item 90) together with the seal (10) from the box
assy (20).
(c) Carefully open the hinged top cover (Ref. to IPL-Fig.2, item 120).
(d) Remove the locking clamps (30) from the attachment straps (Ref. to IPL-Fig.2, item 50) and
the foil bag (40).
(e) Carefully separate the foil bag (40) from the box assy (20).
NOTE: Do not remove the serviceability indicator (50) and the protection adhe-
sive tape (80) from the foil bag (40) unless replacement is necessary.
NOTE: Do not remove the identification plate (90) from box assy (20) unless re-
placement is necessary.
Page 301
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
(a) Remove the foam interlinings (10, 20) from the top cover (120) and the box (150).
(d) Remove the hinges (30) together with the attachment straps (50). Separate the top cover
(120) from the box (150).
NOTE: Do not remove the safety cord (100) from the clamp (90) unless replace-
ment is necessary.
NOTE: Do not remove the stitch (105) from the clamp (90) unless replacement is
necessary.
(i) Remove the rivet (140) and pull out the inspection window (130) of the box (150).
NOTE: Do not remove the instruction label (110) from the top cover (120) unless
replacement is necessary.
(a) Remove the fasteners (20), the windows (20) and the strips (30) from the box
(b) Remove the upper from the lower part of the box (10)
Page 302
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 303
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
CLEANING
WARNING: STRICTLY OBEY THE PROCEDURES FOR THE USE OF OXYGEN EQUIPMENT. DO
NOT USE ANY OIL, GREASE OR OTHER LUBRICANTS MADE FROM PETROL ON
THIS OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE HAZARD.
CLEANING MATERIALS
TABLE 3
2. Procedure
A. Box assy
(a) Clean the box assy with a clean lint-free cloth dipped into hand-warm soapy water and wipe in-
and outside.
(b) Let the box assy dry ten to fifteen minutes or use a clean lint-free cloth to dry.
CAUTION: THE FOIL BAG IS VERY SENSITIVE AGAINST HARD OR METALLIC EFFECTS.
VERY CAREFULLY CLEAN ONLY THE OUTER OF THE FOIL BAG WITH A SOFT,
CLEAN, LINT-FREE CLOTH. DO NOT DAMAGE THE SERVICEABLE INDICATOR
AND ITS TEXTIL STRAP.
Page 401
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 402
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
CHECK
1. General
WARNING: STRICTLY OBEY THE PROCEDURES FOR THE USE OF OXYGEN EQUIPMENT.DO
NOT USE ANY OIL, GREASE OR OTHER PETROL BASED LUBRICANTS ON THIS
OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE HAZARD.
2. Procedure
(b) Check that the inspection window is not matt and does not have scratches. Replace the inspec-
tion window if necessary.
(c) Check that the seal of the box assy is not damaged. If the seal is damaged open the box assy
and check condition of installed parts.
(d) Check that the top cover moves freely on its hinges.
(2) Check the date of manufacture shown on the identification plate and compare the service life time of
the oxycrew. If the service life is out of limit replace the oxycrew.
(3) Visually check the serviceability indicator of the foil bag through the inspection window. If the ser-
viceability indicator is damaged, open the box assy, remove the foil bag (Ref. to DISASSEMBLY)
and continue as specified in step 4.
Page 501
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
NOTE: A damage of the foil bag causes an increase of weight, because of humidity has
gone into it.
(a) Check serviceable indicator of the foil bag for damage. Do a weight test if the serviceable indi-
cator is damaged.
(Ref. to TESTING AND FAULT ISOLATION).
If the weight is out of limit and a life extension no more possible, fully replace the OXYCREW.
NOTE: A repair of the foil bag and smoke hood is not possible. Discard the foil
bag together with the smoke hood as specified in REPAIR
(5) Check of the Identification Plate/Markings
(a) Check that the identification plate and markings of the box assy and the foil bag are to read.
Page 502
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
REPAIR
WARNING: STRICTLY OBEY THE PROCEDURES FOR THE USE OF OXYGEN EQUIPMENT. DO NOT
USE ANY OIL, GREASE OR OTHER PETROL BASED LUBRICANTS ON THIS OXYGEN
EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE HAZARD.
NOTE: Replace all parts found damaged or inoperative in TESTING and FAULT ISOLATION and
CHECK.
REPAIR MATERIALS
TABLE 4
A. Procedure
(a) Remove the foil bag from the box assy as specified in DISASSEMBLY.
(b) Carefully remove the old protective self-adhesive tape from weld seam of the foil bag.
Remove a strap of 35 mm +/-3 mm (1.378 in. +/-0.118 in.) of the paper protection
(Ref. to Fig. 4).
(d) Bond the new self-adhesive protection foil on the old position of foil bag.
Page 601
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
(1) Remove the foil bag from the box assy as specified in DISASSEMBLY.
(2) Remove the cord of the damaged serviceability indicator from the holes of the foil bag.
(3) Put the cord of the new serviceability indicator around the foil bag.
(4) Move one end of the cord through the applicable holes of the self-adhesive protection foil
(DETEAIL A).
(5) Move one end of the cord through the applicable hole in the weld seam and then through the washer
and the new lead seal (DETAIL B).
(6) Move the other end of the cord through the other applicable hole of the weld seam and then through
the washer and the new lead seal.
(7) Put a circular rod beneath the cord in an area where there are no folds in the foil bag.
(8) Align the serviceability indicator with its yellow side to the mid of the orange self-adhesive protection
foil. (Ref. to Fig. 4)
(9) Connect one of the free ends of the cord to an applicable scale or weight.
Page 602
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Serviceability Indicator
B (Yellow side up) 40 mm - 10 mm
Cut cord here (1.5748 in - 0.3937 in)
Remove
Do not remove protection
protection paper paper from
from this area. these ends.
Weld Seam
Self-adhesive
Protection Foil
(Orange side up)
Foil Bag
A Part Number
Manufacturing Date
Weight
Cord
A Circular Rod
Foil Bag
Washer
Lead Seal
Page 603
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
NOTE: The cord of the serviceability indicator must be installed adjacent as possible to the
foil bag. Carefully press weld seam as much as possible to the foil bag.
(10) Hold the free end by hand and apply a load of 8,0 N +/- 1,0 N (1.80 lbf +/- 0.022 lbf) to the other end.
Use lead seal pliers and press the lead seal together.
(13) Put the foil bag back into its box assy and attach with the locking clamps to the attachment straps of
the box assy as specified in ASSEMBLY.
CAUTION: THE CORD WHICH CONNECTS THE LEAD SEALS OF THE YELLOW SERVICE-
ABILITY INDICATOR FOIL IS ONLY FOR THE INSTALLATION. CUT THIS CORD
AFTER FULLY INSTALLATION OF THE FOIL BAG INTO ITS BOX ASSY. IF THE
CORD HAS NOT BEEN CUTTED, THE FUNCTION OF THE SERVICEABILITY IN-
DICATOR IS NOT POSSIBLE.
(14) Cut the cord between the lead seals (Ref. to Fig. 4, DETAIL A).
(1) Open the foil bag and remove the smoke hood as shown in Fig. 3 and 4 of the instruction label on
the top cover.
(2) Start the KO2 cartridge with a pull on its starter lanyard.
NOTE: The oxygen flows with a sound that stops after some 50 seconds, into the
breathing bag.
(3) Pull out the fully oxygen supply part from lower part of the smoke hood.
(5) Disassemble the full oxygen supply and remove the KO2 cartridge including the starter.
Page 604
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
WARNING: STRICTLY OBEY THE REGIONAL PROCEDURES FOR THE USE OF AGGRES-
SIVE ALCALINES AND ACIDS.ALSO OBEY THE REGIONAL PROCEDURES FOR
THE DISCARD OF THE NEUTRAL MADE KO2 CARTRIDGE, THE RUBBER-, THE
PLASTIC- AND METAL PARTS.
(a) Fill a basin with a minimum quantity of 20 litres (5.28 US gal.) of water (For each cartridge).
(b) Put the KO2 cartridge including the starter into the basin.
(c) Add diluted acid (sulphoric- and hydrochloric acid) to make the KO2 cartridge neutral.
At the same time measure the ph value by a usual ph-indicator strip.
(7) Discard the neutral made KO2 cartridge including the starter, and the remaining rubber, plastic and
metal parts.
Page 605
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 606
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
ASSEMBLY
WARNING: STRICTLY OBEY THE PROCEDURES FOR THE USE OF OXYGEN EQUIPMENT. DO NOT
USE ANY OIL, GREASE OR OTHER PETROL BASED LUBRICANTS ON THIS OXYGEN
EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE HAZARD.
NOTE: Make sure that cleaning, check and repair have been done before continue with the as-
sembly.
Tape, self-adhesive
Y4085 F0347
(double-sided)
ASSEMBLY MATERIALS
TABLE 5
2. Procedure
(a) Put the inspection window (130) into the box (150) and attach with the rivet (140).
(c) Put the tape of 0.05 M/0.02 IN (45) upon the lower pin of the middle hinge.
Page 701
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
(d) Put the handle (60) on the top cover (120) and safety with rivets (70) and locking washers (80).
NOTE: Move the eye of the safety cord (100) over the handle (60) before its instal-
lation on the top cover (120).
(e) Put the top cover (120) on the box (150), push the hinges (30) into applicable holes and safety
with the locking washers (40).
(g) Put the handle (60) on the top cover (120) and safety with rivets (70).
(h) Put the top cover (120) on the box (150) and safety with the locking rivets (43).
(j) Prepare two pieces of double-sided self-adhesive tape (Ref. to Table 5) and remove the paper
protection from one side.
(k) Bond each a piece of the self-adhesive tape on the bottom of the box (150) and the top cover
(120).
CAUTION: MAKE SURE THAT THE INSPECTION WINDOW (130) IS NOT CLOSED BY
THE COVER- OR BOX FOAM INTERLINING (10, 20).
(l) Remove the paper protection from the upper side of the self-adhesive tape and put the cover-
and box foam interlining (10, 20) in. Attach the foam interlinings (10, 20) with a short push on
the area of the self-adhesive tape.
(m) If necessary bond a new instruction label (110) on the top of the top cover (120).
Page 702
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
B. Installation of the Foil Bag (Ref. to IPL-Fig. 1 Item 40) into the Box Assy (150).
CAUTION: MAKE SURE THAT THE FOIL BAG (40) AND THE IDENTIFICATION PLATE (90)
OF THE BOX ASSY (20) HAVE THE SAME DATE.IF NOT, TRANSMIT THE DATE
OF THE FOIL BAG (40) TO THE IDENTIFICATION PLATE (90) OF THE BOX
ASSY (20).
CAUTION: MAKE SURE THAT THE YELLOW SERVICEABILITY INDICATOR (50) OF THE
FOIL BAG (40) IS NOT DAMAGED.IF THE SERVICEABILITY INDICATOR (50) IS
DAMAGED, REPLACE IT AS SPECIFIED IN CHPT. REPAIR.
(a) Carefully put the foil bag (40) into the box assy (20). Align the foil bag (40) to the inspection
window (Ref. to IPL-Fig. 2, item 130) so that the serviceability indicator (50) is clearly to see
from the outside.
(b) Attach the foil bag (40) with the locking clamps (30) to the attachment straps
(Ref. to IPL-Fig. 2, item 50) of the box assy (20).
CAUTION: IF THE SERVICEABILITY INDICATOR (50) HAS BEEN REPLACED: CUT THE
CORD FOUND IN BETWEEN OF THE LEAD SEALS OF THE YELLOW INDI-
CATOR FOIL (REF. TO REPAIR, FIG. 4).
IF THE CORD HAS NOT BEEN CUTTED, THE FUNCTION OF THE SER-
VICEABILITY INDICATOR (50) IS NOT POSSIBLE.
(c) Bend the edges of the hinged-side of the top cover (Ref. to IPL-Fig. 2, item 120) to the outer of
the box (Ref. to IPL-Fig. 2, item 150).
CAUTION: MAKE SURE THAT NO PARTS OF THE FOIL BAG (40) ARE IN BETWEEN
WITH THE TOP COVER (REF. TO IPL-FIG. 2, ITEM 120) AND THE BOX
(REF. TO IPL-FIG. 2, ITEM 150) BEFORE CLOSE THE TOP COVER.
(d) Fully close the top cover (Ref. to IPL-Fig. 2, item 120).Align the clamp
(Ref. to IPL-Fig. 2, item 90) with its mid-hole to the head of the rivet that attaches the inspection
window (Ref. to IPL-Fig. 2, item 130) and lock the box assy (20).
NOTE: Make sure that the serviceability indicator (50) is clearly to see through the
inspection window (Ref. to IPL-Fig. 2, item 130).
C. Keep the OXYCREW for a time of 24 hours into a shelf. Then do a final check of the serviceability
indicator (50).
D. Bond a new box seal (10) over the clamp (Ref. to IPL-Fig. 2, item 90) if the serviceability indicator
(50) is not damaged. If the serviceability indicator (50) is damaged, disassemble the OXYCREW
again (Ref. to DISASSEMBLY) and do a weight test with the foil bag (40) (Ref. to TESTING AND
FAULT ISOLATION).
Page 703
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
A. Packaging
The OXYCREW has a sufficient preservation treatment. Keep the OXYCREW packaged as speci-
fied in the instructions set out in the Specification Air Transport Association (ATA) 300. The part
number and the date of manufacture must be clearly to read on the outer.
B. Storage Instructions
Keep units on shelves which permit a free flow of air, free of moist, far from injury vapours vibration
sources and direct heat or sunlight.
C. Transport
Page 704
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 705
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
1. General
This ILLUSTRATED PARTS LIST (Refered as to the IPL) contains the complete listing of all parts re-
placeable of the OXYCREW.
2. Material Arrangement
A. Introduction
The introduction contains all explanatory information for the individual sections as is necessary for use
the IPL. The introduction further contains a list of abbreviations used in the detailed parts list as well as a
list of manufacturer codes together with manufacturer names and addresses.
B. Numerical Index
This section contains a listing of part numbers of all items listed in the detailed parts list in alphanumeri-
cal sequence with cross-reference to respective Fig. / Item Nos. as well as units per assy. The order of
precedence in beginning the part number arrangement at the extreme left-hand (first) position is as fol-
lows:
- letters A through Z (except 'O' to be considered as zero)
- numerals 0 to 9
- for subsequent rows, the order is a dash
- letters A through Z (except 'O' to be considered as zero)
- numerals 0 to 9
The indenture system used in the Detailed Parts List shows the relationship of parts and
assemblies to next higher assemblies as follows:
(a) Find the part number in the numerical index. Note figure and item number.
(c) Locate the part on illustration and in the parts list by item number.
(a) Refer to figure 1 and look for the title of figure in which the part should be shown.
4. List of Abbreviations
ABBREVIATION DESCRIPTION
AR As required
DET Detail
EFF Effective / effectivity
FIG Figure
IPL Illustrated parts list
NHA Next higher assy
NP Not procurable
PN Part number
RF Reference
REQ Required
SPSD Superseded
TTL Total
5. List of Vendors
F0347 3M FRANCE
Blvd de Loise
F-95006 CERGYPONTOISE Cedex, FRANCE
6. Alpha-Numerical Index
D4932 1 060A 2
D4932-03 1 060B 1
DIN125A4-3A2 2 80 2
DIN7331A2/4X5 2 -140C 1
DIN7331A3-6X6 2 -043 6
DIN7331A3-6X6 2 -070C 2
E28095-02 3 -001A RF
E28096-01 3 020A 1
E28165 2 150A 1
E28165-02 2 150B 1
E28178-02 3 010A 1
E28180 1 -001A RF
E28180-10 1 -001B RF
E28180-10-0001 1 -001C RF
E28180-10-0002 1 -001D RF
E28181 2 120A 1
E28181-02 2 120B 1
E28183-04 3 -001C RF
E28194 2 110A 1
E28194-02 2 110B 1
E28195 1 020A 1
E28195 2 -001A RF
E28196 2 060A 1
E28196-02 2 060B 1
E28197 1 090A 1
E28198 2 020A 1
E28205-01 1 -020D 1
E28205-01 2 -001D RF
E28234 2 070A 2
E28234-00 2 070B 2
E28238 2 090A 1
E28238-04 2 090B 1
E28244 2 130A 1
E28244-03 2 130B 1
E28244 2 130A 1
E28244-03 2 130B 1
E28246 1 050A 1
E28246-01 1 050B 1
E28247 2 010A 1
E28247-01 2 010B 1
E28247-01 2 020B 1
E28292-00 3 -001D RF
E28297 1 010A 1
E28297-00 1 010B 1
E28297-01 1 010C 1
E28297-02 1 010D 1
E28320 1 040A 1
E28320-04 1 040B 1
E28330 1 080A 1
E28330-00 1 080B 1
E28330-02 1 080C 1
E28331-03 3 -001E RF
E28344 2 -105A 1
E28344-01 2 -105B 1
E28361 2 045A AR
E28361-00 2 045B AR
E28395-00 1 -020B 1
E28395-01 1 -020C 1
E28395-00 2 -001B RF
E28395-01 2 -001C RF
E28396 2 -120C 1
E28396-00 2 -120D 1
E28397 2 -150C 1
E28397-00 2 -150D 1
E28398 2 -030C 1
E28398-00 2 -030D 1
E28399 2 -060C 1
E28399-00 2 -060D 1
E28400 2 -130C 1
E28400-00 2 -130D 1
E28401-00 2 -050D 2
E28407-00 1 090B 1
E28601-00 2A -001 1
E28602-00 2A 010 2
E28604-00 2A 020 2
E28660-00-0001 1 040C 1
E28672-00 2A 040 2
E28673-00 2A 030 2
E60031-03 1 090C 1
R32519-01 2 050B 2
R51287 2 030A 3
R51287-04 2 030B 3
1205668 2 100A 1
1205668-00 2 100B 1
1330233 1 070A 1
1330233-00 1 070B 1
6301009 2 140A 1
6301009-00 2 140B 1
6802008 2 040A 6
6802008-00 2 040B 6
8711312 1 030A 2
8711312-00 1 030B 2
Page 1001
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 1002
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
BOX ASSY
FIGURE 2
Page 1005
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 1006
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 1008
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
BOX ASSY
FIGURE 2A
Page 1009
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 1010
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
BRACKET
FIGURE 3
Page 1011
35-10-25 JUL 30/11
COMPONENT MAINTENANCE MANUAL E28180-SERIES
Page 1012