Manejadora MC Quay 10 Ton

You might also like

Download as pdf
Download as pdf
You are on page 1of 28
FORM NO. H11-508 REV, 13 ‘Supersedes Form No. K11-508 Rov. 12 Commercial M 0 © Air Handler ic uay ee or) a member of DAIKIN group 15 & 20TON MODEL [53 & 70 kW] 7.5 & 10TON MODEL 6 & 35 kW] 7.5 THROUGH 20 NOMINAL TON UNITS [26 THROUGH 70 kW] MHGE-075, 100, 150 a 200 LISTED TABLE OF CONTENTS Standard Unit Features. 2 Component Air Resistance " ‘Component Location 3 Blower Performance Curves: 1114 Unit Dimensions 4 Evaporator Performance Data 15816 Physical Data Table 5 Electrical Data Table. 7 Drive Package Data, 8 Typical Wiking Connections 18 Performance Data—Dual Straight Cool Condensing Accessories 18-23 Units with Air Handler. 7 Piping 24 Indoor Blower Performance Data 8-10 Guide Specifications 25 Limited Warranty 25 MODEL NUMBER IDENTIFICATION MoH G too ZL eouay pe Design Seras olng Only TL _____ nine acta se pase 6 so optnal eld apples) Optra N= Optenal iets Supp) (02 Optional (Fld Supptee) Elects Designation 5250-0 (075100 ony) Nominal Tons 75 Tens (26 kt) wah ave package on 0.0 Tors [35 0) Tors [53 HA] 0 Tors [0 HA] UNIT FEATURES. ‘CABINET—Powder coat painted. Matching discharge plenums and decorative supply and retum air griles are available for use hen units are to be installed within conditioned space. MOTOR—Inherently protected motors are mounted inside of insulated cabinet to reduce motor noise and provide a neat looking installation. A choice of motor horsepowers and drive combinations are available to allow you to meet specified CFM at various static pressures up to 2" [498 «Pal external static pressure. Motors and mounts in 15 ton [53 KW] and 20 ton '70 kW] units may be relocated in field to opposite side of blower scroll for accessibilly, LOW PROFILE—Allows for horizontal installation in most standard drop ceiling applications, and the movement of Units through most standard doorways for addition or replacement work. ‘THERMAL EXPANSION VALVES—Standard all models. FILTERS—One inch [25 mm] throwaway fers are standard, bul filer racks are designed to accept either one inch [25 mmm} fr two inch [51 mm) fiers. EVAPORATOR COIL—Two circuit, interlaced row split coils, are constructed with copper tubes and aluminum fins mechan cally bonded to the tubes for maximum heat transfer capabli- ties, All col assomblies are leak tested up to 450 PSIG [3100 kPa] intemal pressure prior to installation into units REFRIGERANT CONNECTIONS—Field piping connections are made through a fixed post between two side access panels fon eltner side of the unit. Allows flexibility to meet most fleld Conditions as well as full accessibiliy after the installation is complete. Units may be used with two straight cool condens- ing units or single circuit manifolded in the field using the cop- per fitings shipped with each unit, The MHGF Alr Handler has hol been tested, rated or certlied to operate with dual remote heat pumps. DRAIN PAN—The galvanized steel drain pan is designed to trap condensate in either vertical or horizontal installations, Condensate drain connections are located on both sides of the Lnitallowing complete lexiblity to meet most field conditions. SERVICE ACCESS—Two removable panels on top and each side of the unit are easily removed for access to motors, blow- fers, sheaves, and fiters. HORIZONTAL OR VERTICAL—All models are designed for either application and can be installed in elther position as supplied from the factory. ‘TESTING—Al units are run tested at the factory prior to ship- ‘ment, Units are shipped with @ holding charge of nitrogen. 2 McQuay [ 1Designates Metre Conversions COMPONENT LOCATION FILTERS BELT DRIVE SHEAVES. BALL BEARINGS 15 & 20TON Tile & 10TON 153 & 70 kW] REFRIGERANT CONNECTION [26 & 35 kW] POWER ENTRANCE CONDENSATE DRAIN. 15 ton [53 KW] & 20 ton [70 KW] unit with side panel 7'eton [26 KW] & 10 ton [35 KV] unit with side panel removed for blower and air fiter access. removed for coll connections and air filter access. ‘TX VALVES MHGE- SINGLE CIRCUIT MANIFOLD MHGE- T'-20TON Ti 20TON REFRIGERANT CONNECTION [26-70 kW] EITHER SIDE. [26-70 kw} [Designates Metric Conversions McQuay UNIT DIMENSIONS ® vonwew « © 7/2 AND 10 NOMINAL TONS [26 AND 35 kW] TERE OETA ee cent arisen Pretest aera L es [____CORNER WEIGHTS, L8S.(ke] | ‘TOTAL MODEL A B c D WEIGHT a ec eo ~~. 100 93 (42) 82 (37) 92 (42) 80 [36] 37 157) ferum amorous = ea pae] wT: wT oe er 1) ate] eercore [oe i — see a c ce Ea were EB cal ech | ai 7 seme 7 eae ; ee 2s be oem ca “TEAS eanaancoedelnineong nes pagancntoc st o. TOP VIEW oo 15 AND 20 NOMINAL TONS [53 & 70 kW] RERENTTETAESALAT — oa eee owen or Aeron Sr [aera eee CORREA WERT Sal] sora MODEL A a c D WEIGHT | wpa rer rer | oe e 200 159172) | 142 (64) | 129/59] | 115 (52) [545 (247) peru AN oP = es 4m MOTH Oe PHO ve nea — ty ane ae awn sere fms | ar |e xe [eee seven |) | “rn sole res al a sure flu | i eoy | ime ‘She (87). Bhat 09) som | £ eel — pay emg ear bee Ee is ‘ve [0] NPT FEMALE McQuay [1 Designates Metric Conversions PHYSICAL DATA TABLE WODEL NO, MHGE- 1991 x 1600 x 1943] TEM ws 00 7 200 Nona Se Tore TMT TSS] Tres] B15 BOO Nominal CFM [Us] @ Rates ES. 2000 @ 28 4000 @ 20 2000 @ 35, 2000 @ 40 in kal of water (iste @ 03) 208 @ 075) (e822 @ 87 (a7re 8 <8) Ipanaag SSO RPUTITTO THE 7) ZAP OT] = = wotor 1708 RPM IW 1 HP resi HEMP) 2 HP ast SHP [37201 ; TEHP. PHP OH, 8H SHR SH Ta HP otional~ 1725 RPM IW) 3.9 (nite. 1a8t) (149s, 2087 (2087, 9728) (5593) awh mj Tox Tox 12 18x15 1exi8 Blower Size—clameter & wic fee} [305 x 305] [305 x 305) (457 x 381) (457 x 457) Blower Shalt Sao Ganete hn] Te) PH TT8) TI TES] MolorSheave Sze 3450 RPNTT Te20 ner | aaa (6H) = = ‘Aajstnent (tn 1728 APM 2 aesateoria | sosooxien | ar-4speso | 425s (i00t40) Toi Face Are, 29, fot me 702 [88] 102 [95 765 (1.55) 765 (1.55) Goll Tube Diameter in. (mmm) ¥e [10] $e (10) [10] Ye [10] ol Rows Boop Fina Pench fr EES 5 (55 391511 a5 (581 Fetrgerant Conol= Theal tiga Coal Thoma "ANEAHCA (2) AnesHca@) | y7028vecA@ | veIexvecac Fie Si, fr Textexi Tex75x1 FxEXI FxPEXT (Number Requires) Disposable™ twosxeasx25) | ooxeasx2s) | (508x605 x25) | (So8x695 x25) CABINET fen Powder Paint Powder Paint Powder Paint Powder Paint Sheet Meta Galvanized Galvanzed Galvanized Galvanized ge (roMtna Te 18 18 18 8 Sie 78. 16 7. 7 Botton 7 8 7%. 76. Doors and Covers 3 i 2 en 30 min NIT WEIGHTS: Operating #25) he] 220 150 aurissn 495 2051 545 2471 Shipping tbs) Fa] 350 159) 367166 520 (240) 580 283) PACKAGED DIMENSIONS BU ase xSTIE | SE KSe A STIG | a6 xea x761F | 07x69" x 761 (Wt i (p00 «422% 1454)_| oo 1422 x 1454 1981 x 1600 x 1943) "Oniwil accept (ST aml hers NOTE: Ia factory accessory heater kit isnot used, 2 field supplied fan contactors required and should have a 24 volt col with contacts rated to handle the evaporator motor FLA a desired voliage. factory supplied 30 Amp 3 Pole (Part ¥52-17810-83) oF 30 Amp 2 Pale (Par 42-17758-03) Contactor may be purchased from the Parte Department. [ 1Designates Metric Conversions McQuay 5 DRIVE PACKAGE DATA OMWAL] DRIVE gg, [_SHEAVE SELECTIONS Wm] — WOTOR —| APROX BLOWER o OTOR SHEE TORRE OPE rows | PACKAGE WOTORBORE [BLOWER [WPTMIPHASE[-O-[ [2 [28 TS] | S| Kafana | ee TreTe] ars eal] + (awjad | vu] Veo] rao] Hs | Vo] vos] oe] — Kaeo [tee [eral ar eel] 1 (awyta [Teas] 5 ooo | — | woo] 700] oes | — 2S [aise [rans [ors ean [etter | soos woo [was | 425 [700] 750] — asso [a2 [ator eee | 5 RT Tey90 [Tres [ow 055 | — [To20] was | os] — DNase 8 7 Yael | 875 eal [ a1 ayaa [ ses] Hao] =| oo [ees Ton [= a 41530, 3444 (86-112) | 9.75 (248) | 15 [1119¥80 | 790| 7e0| 725| — [ 690 660] 630 | — K 41530 [405.0% | [102-127-168] | 9.75 [248] | 1S [itiavse | sas] ess] 25[ — | 795] 70] 730 | — . Kaas [ 28 | ral ws ear] —eiveeyio_[vva0| Toro] was | =| wa0| ws | 70] = Ba 540 | 46-567 | [117-142-22) | 8.75 (248) | 2 1491/30 | 895] 960] 930] — | a95| B60] @25| — Hasso [2 37 [atari 75 foe | — 3 oea7V00_[t1es [tomo Toss] — [Toro | was | 9 | — aN atsao [ars em vetasoat| 77s tier | —svaryan[taes [190] so] — [1rt0 oP] Tao] — oo asae 8776 [sry | 875 eal [ sana [ ano aso] ano — | as [iso 115 [= Kaeo faraie| retocsar[ ra esol —erianiee | sas woo] sao [=] ses] sas 510 0 ts [oe arse fara [wero [44 ao0 | —aiz0o790 | rao | 705 oao | — [a5] e200 [0 CE NC WR oP [acon an-t520/[ Ta sr] —siaaayan [wes] 6o| vas | —[ oto] ens] ae [eas ROBES Yas [oma] [Tawa | —Scaantee | aso | wes aon [ = Pree | as 7 as 28, (2 ersany fac | oe [Toon | Ts pssoren | 955 sz5| ons | — | wes] 035] a5 [70 i —araarey [esse [ooo] ease | 75 serayo0_[woso| ews] oo — | vas wo oss [ais "fal ich later tes Minimum and maximum pic anal show akbl lr sheave, 0 Fal Suped tor Save Browning IVP7S, Blower Sheave: Browning AZ100, Motor 2HP [1491 W], 4 Pole, 0) Sheave: Browning A780), Browning IVP6S, Blower Sheave: Browning BKT10), 1 Fila Supplied (Motor Sheave: Browning IVP75, Blower Sheave: Browning A780), + Fila Supplied (Motor Sheave: Browming IVPSO, Blower Sheave: Browning AZ100), Factory sheave cottings are shown in bola print. [1 Designates Metric Conversions 6 McQuay 4 Feld Supplied (Motor Sheave: drowning IVP85, Blower 1 Field Supplied (Motor Sheave: “Tho K.L. and M drives are avaliable from the factory. The JN, and O drives are not avaliabe om the {factory and these sheaves and bals must be eld supplied. A motor change isnot required. The field supplied sheaves and bel are standard shlf fers ‘hat ae radlyavalasle ftom local equipment supply nouses. The chart above ges the necessalyspectications for these ld supplied sheaves and bes. PERFORMANCE DATA @ ARI STANDARD CONDITIONS—COOLING Dual Straight Cool Condensing Unit with Air Handler ODE NUMBERS reed aesemon 9908 ouTDOOR iNDOGA NETTOTAL NE NET soup | ew 42D MHGE-1002_ (82,000 [24.03] 66,500 [19.49] 15,500 [4.54] ‘9.00 a4 ‘3,000 (1415) PERFORMANCE DATA @ ARI STANDARD CONDITIONS—COOLING ‘OUTDOOR INDOOR NET TOTAL NET NET goun cFM UNIT COIL AND/OR: ‘CAPACITY ‘SENSIBLE LATENT EER [Us] McQuay 7 senate eu oN WT stades SUN EEE EEEEEEEEEEEEEEEEE EE E Krisheatfoior| ons ocr one [or coer oon] SEE TE TE TE FE EEE EE Ephron vv noe on foez ne [ese ore [sr sez on] ==EEE esi ees uz so fsceosnforefoesfossz es Josrzfus[ocreoee eee fouz| sos vai] sre [671 s20l oor] g oe se sve ono fore ons os sn fureznlsot| see [ozs fotze owoeaze evn eve forac| est [sz zm one] [eal a se ove orfoozloosfoez zo, fntzfoes[ouzlovelooz[or fone owcore fox fos [set om ooo] W rz oz zz stow arin ore ocr |sex[ozou eros zr Pas [uci ve [ozs [soe Jose [strive lovesoue oss ose [sur] see| — | — ome] sez vez fz onions sr ovr sr ose fox faz | [oso Jose fost fous foe fare [oer |sve fretfovelos.oe osu |e one os sua ose [ooze eo fos oro eer fons [oes|sse loss |ove Jott forts fst [svolsee rou pee fos [sc [owe [ons [ — | — oe [nau im [waul m [nal m [nasl m [wal me [mal m [nal m aul m [nlm [wal m juan m [nl 7m na fos viozfurvien fires ifereicslioraissuraiss|seeirs|ecciesloroizsurorsfisceosrrue [roe [ura [sce [reas usele ous bao [ec] dV 40 SSHONI~d'S'S ‘A/Z 001-39HW I pea faa et sor t x sap mat bs $ a ww Hw lw Ew Ew FE CET ww Ew FEI w FE uw" [nt " Iwata ® asl * nas [nau ® Ina aul " nae " asl " Iaael "Iwas" nat | ay foselo [arate [iarolys|iarols swale [urolss|ierers are et carole [rots [rely [uve [eros [eran | 2 (24) feat 0 t 1 on ta inl cit ou wail" ore [ows one a are oz ce iar sae fz sca rerfour ox fooy oe fs os [oe Jost sz [ows fox ors [ove fos [ows par us| — |= [= [= [= [= [= [= sar ss [os oar [avs fer [sve] = [= [= [= [= = [= [= Wocioasruraisiseriederjordziurileooerae [oar furor [sroe lees foray lurve wwe fear] win | oe [ec] ¥aIWM 40 S3HONI—d'S' “oe A/ZS2O-39HW = (1109 AYG) SONVINYOsYSd YSMO1E YOOGNI rors oor oer oor oer for oor orn xf foros fos for foc foorforefss fou oslo [tole [lero McQuay 8 suorsienueg 2100W seveusiseq ] [neato] beads snare = inde [97 seal os zal va or zal on a * va conse ee soa t 6 soon Fiona " i 7 1 is , Fn oh saoy =u ma a en os al a sasen bee a = 22 Isnrs joses = 081 os ‘ lemon Tuga] ™ fas [nau] [wax [i Mt Tugel ™ [na m ™ Tiasl ™ foal ™ fas! ™ fa! ™ lies] ™ naw! |g fogoloetcroies levels avolet [trols [urate [iaeotv' ero ex[iorw ero v1 [ere Terele [avels [rely [ure [aroe [aren] M2 a] [ect] HALWM 40 SSHONI—d’S'3 MH OOL-SDHW = (1109 ANG) SONVIWHOAY3d HSMO18 HOOGNI 9 McQuay suojsionvog oo seveusjseq ] IESE, SEE EEEEEEEEE cE bail ors ze foal sea fel or aca] ove os [oes ee Jzzs| on ous] son owe suc] st srs] oe srs sx evs or [zs ce [ere ost szer ore ave fav] se oz] or ocr] se eer ose [oon ove [ore] [on] oer i ov] fora re [eo [seo oe Joe wee ev] sce cen os rose oz [sve ssi oor[ sz swe gs | — | — se ose] oz fous see] — [| — [— [=[—[—|— so [oreo aor rave os m1 ser fe] su zr] soe coc] se oct se [ost sz [sre su sr] sez ou = FE EEEEEEEEE fine] , ane foc] sae ose] sr eae] sx ozs son [sus cz Jove] 6 [ose] ons sel —[-[I EEE ELE EEE E- [sreoriones 596 fi] ore oo] oz ose] oo Jeez] oz Jez sz [una onc [sz] sux = EE EEEEEEEEEE [EE [ [reseloooe [wal moa] mt [na] ma] m [eam [aul [wcul m [ma] m [wa] m Jan) m [nay maa] loam [waa ma fos oie z|urore [ier aie t|terorifiorsiss |uevist ferwietlforaie )uediv[isvoion reroie [toreie ws aus fea] Ha1WM 40 S3HONI~d'S'S AlZ 002-4DHN a see ore us [sr oet are] nw sr] Ser] oss os [ove abe Jon soe [eur fans ore fone s.e fs [oor fae oe os Jone] ze [ors] oe one bx [sz ze [nue] soe fee] sec fare] <9 lve [onze se ove |sze| sx foue| oe fone ze [ora ove fvzel on [ese o17fvselonc fore] ser ce ose sw eaz| ove sz zx ova ve [vez a [zzz ac [onze Jere] se fe [00 fz] or osu] ss srt [ar ove oss zs os Joos] ss | — | — [== |= [= [onus ore) ose ose |svz| sex orez| ox ozzy ve [siz [zz st [ows [oe far [ou fvc [oe fu] so» or] so [oer os Jose] es or oer] os Jose [one | = [=| = |= [= [= [fers oor fosolozfureies fisrvies[ieroic forse t|uraist|sreirs|ecdirsorsir jurovifsrooyferae [rer furoe [sre [ees foray lure [irae fra] wo | oe [ed] WalWM 40 S3HONI—d'S'a “oe A/Z 0SL-39HIN sae] oz see ute owe 1 ove so foe ze fuse ove og oes os Jozi es Joss ows ens] sis fers | oer coos) 1 os os ss [svi vs fri | sis oo] coy | — | — [evs ozs su oss oss [seize fous fear| — [ — | = | = [vreszl ony ois ase] oz ee oe ss oso lovz oes osm se (1109 Ava) [v1 02] NOL OZ 8 [4 €S] NOLSL-3DHW SONVWHOIHAd H4IMO1d HOOGNI McQuay 10 COMPONENT AIR RESISTANCE MHGE 7.5 TON [26 kW] & 10 TON [35 kW] cm Tos] a0 | BOO] S06) | 0] WD] A) tna, [ey] prom | pits | cee] pase] wag | wim | sg Ee ED ES CE SE SE ss Rea rotor voter ot oes om | a0 [so 0 [70 i [6024 Here (UA Dano’ ow [wn [vos om 2a] [wz eo] | ese or ov] no [aos 2) ST A EE TE Tire oso | oor 808 | 97008 oe | 5am | 5a [ao [58 Sacer Fann font fotos tora oss over ons eet oo oes ao owe e0(om7 e000) MHGE 15 TON [53 kW] cm || a) S| as | | pmetn | parr | asm | tee | pao | ass | po [ome | eo ES SO Els Ror smw one —[ 295070 [som 07] [so om oe aso 2 | sz | 0 T7] [0L A A A RO CT Desshrge Gs Se ie Ope oH | OL oe Loe ood oes oom | 5 os [07 [08 wie rao eos 0008 vor | 5som | seo aoa [s6LoT [977 Sacre Fara ans totrf os tora oss ora ons oat aoe a0 oan [eo os7 a0) MHGE 20 TON [70 kW] cm Baa) | Ta Tao as {3020 L/s] | (3209 Ls] | (3398 Lis] | (3586 Ls] | (3776 Lis} | [3964 Lis} | (4153 Us) | [4342 Ls] | [4531 Us} Els Her RH SRW [20a | zor ana zsoa [ao (o7t| sore so om | ae] OCH ssa 2600500720, oa |e | 0 az | 50 [ soe [so Ye [0112 Hers Be (UA Dares] ow | Too oan] [vod tes] esa xox | as ee] |e 35) Dice le (ee Oper 25 ao [oor oa] oom | [ot] oreo oe ov | sa [oa [ove wi 54 ra 05a 07 re oon xg |r o0 | 15007 [10047 [2005 ae sap [ona eon enon a0 oe a0 (oe 0 ora eon 0 (ove [70 NOTE fe pene SERRE ed ens cen CAVES BLOWER PERFORMANCE CURVES—7.5 TON [26 kW] (WET COIL) sm TSTON RSH -KORVE =m TSTON ASR DAVE us i F i wis wee bs : "75 TON [26 KW} DRIVE [1 Designates Metric Conversions 7 BLOWER PERFORMANCE CURVES—10 TON [35 kW] (WET COIL) 10 TON [35 kW] (MHGF-100 ONLY) ‘OTON [35 KW) ‘JORIVE KDRIVE, ene |] 3 OTON [35 KW] MDRIVE Y 10 TON [35 KW] ‘OTON 35 Kw] NDRIVE . ODRIVE 42 McQuay 1 Designates Metric Conversions BLOWER PERFORMANCE CURVES—15 TON [53 kW] (WET COIL) 15 TON (59 KW) MDRIVE 18 TON [52 kW] NDRIVE 1S TON [53 KW] KDRIVE, 15 TON53 KW) LDRIVE [Designates Metric Conversions McQuay BLOWER PERFORMANCE CURVES—20 TON [70 kW] (WET COIL) 20 TON [70 kW} KORIVE 20 TON [70 kW] LORIVE 20 TON [70 kW] MORIVE 14 McQuay [ 1Designates Metric Conversions EVAPORATOR PERFORMANCE DATA EVAPORATOR/AIR HANDLER MHGE-075 @ 3000 CFM [1416 L/s] wae evap EVAPORATOR ENTERING ARK OB—FTC} eve | er | tout | Wat [em [es [oan [stor | soma [ en Teme | we awe SENSIBLE CAPACITY Fre) | ARMS | were | Awe TC IC sone | ees Paani | esoiesy | raatrey | reales | razr | reales] | 7a a5) as_| eatin, | sonata | soatio, | soatten | reaped | sore | sotslaor | sontfaral | road seal GS | Shs, | testes | Sosho | eaznest | Frater | srzbee | tosstera, | tooalea | tase) Hilave | wostsny | Stein) | 0" | Fee zzq | serien | toselaoal | tivelsea | rare ser) reba | Hesiens, | fasta | — | mararn | tnaten | toretana, | Heslsea | rated, soiis) | aoairas) [sasia) | aearee [| aiiea) | sealiee) | aoaiies) | aaa iiea]} sea lias] wo fauty | ssepen | earn | Shed | Ssied | sais | Sas] wakes | Sees a3, | setts, | saben: | sana | Sass, | sretien | Stapea | setfenay | stoateea | sz20(eo, Has | iorsiaes, | Serta) | =P | seaies | Gerlaeg | seatersl | tongisin | taxes) lea | tevoiseas | Seats, | — | esairesi | reatasai | ssetaral | tora tral | raztbsa) sais) | ae ray [seria | mapa [ pee rar} zee ar] aaa ira) | zea ray} zee 72] as feuty | cosden | esata, | Medea | erdeal) Sogdea | Gesdea |] sein | Sogden s | Gra, | srsiea | aces | ariza | sraites | Mebro | soled | srsted | srebesl | arpers} | 1325 (808) | 57-7 (14) = 55.5 [163] | 69.8[205) | 84.0(246) | 98.3 [288] | 112.5 (33.0) Bla | ieesten | Seats, | = | Seanez | seriooa) | setecel | sutra | ria lsa0) sre] seat | — = ~ = “ co fatty | aoe |eeats, | nie | wep) wae | ween] seen | aa eo 3, | erin, | Sotuos | seats, | S27 foal | droge) sadrs | tetgos | orgs | iordss Sars | weotny | eosne | °L"| Betas | seetve | feabrey | settesa | s023 00) shat | Wosiern | een | — | assras | Sesiva | faeprey | seopsa | toed oo) EVAPORATOR/AIR HANDLER MHGE-100 @ 3800 CFM [1793 L/s] TTT | wero Pao wy] | eezare | estea | maT Geo] werrieo | a7 Rea | aT RET as faut | tezaee | at Bl | sree | toaiio | toes | taste | ieerked | wercee as, | she | testes: | soorer | si3ee | ‘costae | tiralsea | tasziooa, | terstes | tree tse) [81] 71 121-5) | 221-7 65.0) | 52611 = 92.4 (27.1) | 110.7 (32.4) | 129.0[37.8] | 147.3 [43.2] | 165.6 [48.5] Blea" | seerirees | Ssata,_| = | ssviasn | teolsoa | taestasey | teoeletal | rane a) Salis | esa peo, [aos iio | a17aaa [seo | eselze0r | soa(reo| | soe (rea) } ese [780] wo [aati | seseo | snstios)| iselex | sezpre | neste | ssevbea | werfaeal | se 00 dt, | Shs | tesolirs, | Sanna | Tesa0% | ssoues | tarsi | tasotes, | tooled | teaziers) Slava | iorsiseo, | Sona | °°" | doozen | toroaea | nessa | rarstoal | rssetsa) seh | geeoteeol | Srshe_| — | Seotzesi | “ssdbrei | nissiaest | tarelaeal | tant ienal Solis] | searieo) [sara | srariao | ecoiren)} ete (tool | sasiieg) | eto iiea) | ets (to0) as |estin [scones | Sana” | esetes | arsizen | roofs | roots | roolest | 1900 e031 as | Grtia, | tacts | setts) | ssonral | teagen | ‘selena | trast | tsczlan | tor1 a0) Hive | woowss | areca | 2" | Faure | sotaea | nosey | regieed | reones, rebut | were | Sones | — | eeatioe | serra | wooaiaoal | tanrhen | anole) sil} sir ea} sora | s7 pa] a7 Ba] a7 ea] m7 ea] a7 pa] m7 Bal so fauty | sadon | eeiia | fords | deze] Sader | S2ien] Blin | Haus7 so | Sri. | worstes | Sects: | asetian | Scofien | eozpea | worsteen | sorzgoa | irtheal 10) | 7121.5) | 1383 (40.5) | 60.3 16) = 600/176) | 783/230) | 966/28.) | 1149[33.7] | 133.2 (59.0) nba | istcs | eet | — | sssues | repre | seseral | nosteed | aaron NOTES: Total and sensible capacty ie gross, wth na deduction forindocr Blower motor heat. 2. Inerpolaion is permissible, donot extrapolate AIRFLOW CORRECTION FACTORS MHGE-075 @ 3000 CFM [1416 L/s] MHGE-100 @ 3800 CFM [1793 L/s] TACTUAL—CFM ] 2400 ] 2600 | 2800 | 000 [3200] a400 | 3600 | 3060 | 3200 | 3400 | 9800 | 9800 ] 4000 ] 4200 ] 4400 | 4800 ] 4800 {Us} | 11193 | 112274921) [114164 |11510)| 1605 | 1698) 1416) | (1510) |[1605)] (1609) | 1780) | 888 | (1982) |[2077)|12171) [12265 Froracwan | aes | 080 | 09s | 1.00 | 1.00 | 109 | 1.19 | os | oo | 08a | a7 | 1.00 | 108 | 1.06 | 1.10 | 1.12 | 15 [SENSIBLE MBH] 083 | ose [oes [1.00 [106 [ 11 [116 [oa2 | oer | os [oss [100] 104 | 108 | ita paar [aan NOTES: ¥- tfuliply conection factor mes gross performance dala 2. Resulting sensible capacty cannot exceed total capac [Designates Metric Conversions McQuay 15 EVAPORATOR PERFORMANCE DATA EVAPORATOR/AIR HANDLER MHGE-150 @ 6000 CFM [2832 L/s] EVAPORATOR ENTERING AR OS—FTC] evar ene ewe | fuer | come | Sve [em [es [oan [ase | sonst eT Teme | aimwe | CAPS, | ate SENGIGLE CAPACITY el | Aer *Fre) ar _[_wERTT [wen [wR eT maT [wT waa —| BOE wT Op] | taza lass | ysos seat | veez we) | toea se | weea 67) | vee2 67) as | eetit, [ites fn | cost | Heston | tieraen | tates | lesstea | aeceed | fosiern Gh, | era, eee fen | Sethe | sterol | iacovoa | tra2lsos | sooajsnn | denefeea | ase sa 81 | Tiers fares iota. | seat: | 2" | ieee tea) | ioraitea | teeeloea | soeteen | serairoa) Hla” [sesoiora| | Srstta|_ | = | saeatasal | tsnoleet] | werfsaa) | 2oee|eo) | 2aes oa] SS] ]Hves AMP SUTIN) | TORRWOTL | Ties 9671 Pes eer! | Wesiee71 | Was 71 Tes e671 wo | cer, [irs Gna | Sota, | “sestaen | tro sea | es ucs | eaten | testes | tesla dt, | Seka, ase era | Stat, | scostuea | iansarn | troase | tarzecn | sestees | sara lera His [arr feral | sro) |S" | een | teaatae | irtatsoay | Tans ees | Zar leon ‘ales [soz seal | sostis | — | tonzianat | tara ao | tenateesl | tesspeern | 2019 ea saa | m2 ern psesnea | vam | marin | mani] mapin | avin | mapi7 as | solir| [rteo fra | soattar” | ar2tua | sono onal | veolers) | veeoteral | weolral | weoleral #5 | colts, [fees sce | gratia, | austere! | tits em | taerars, | terstioa| | taesiesa | tees ecal Tiara [2es7 fenay | Seat, | =" | “Sesang | teratoral | isosteso) | tenslesal | arta leat) bal” [fase fea | erates | — | staira | Toeatese, | Wosteens | treetees | Soe oral sais | 272 two Psraa | are wo | ava wal | ara wor] ara wa | 27 wal] 272 ol so jecnn [aca des | Sane | Sadea | sous? | Nome | sake] suse | adel GJ orhe, fists ts | sorts, | seettesi | Stelare | vasolece | usnsteral | wrstars | setstetsy Tir [fans Soa | erat, | MSU) Sach | Moe ees | tansleos| | teerlas) | too soa ‘leat [area irra | svta, | = | Trsiaen | tosovere, | torsional | tezalera | toa ee EVAPORATOR/AIR HANDLER MHGE-200 @ 8000 CFM [3776 L/s] THEO Tea] Wael | aeGeaT | BRT ea | DOTER | meaTeRT | meOTeT | ROOT as | solir, [ase se | Soatty, | lertara | tone sem | aoesima | areriern | avarice | aeeresel Ss | Srtal, laos eer | Sestin | Meolers| | isczisea | daealesa | Sees rel | Soretees| | sees ern Tiers fasronenr, | grata, | ="! | fete aea | Tees eee, | ssoatees, | areola | stra ery mba [seeriven | erates | = | terrana | tosans | sosieral | seater | Sane neal Sse) Jerry ea) | earls] | TeSav@a] | aoes seal Pav77 seal | avrrisaal | arr7ieeal P2077 6ea] vo | ech fame Get | Salt | eteteea | fase ase | Zesofee | dealer | dacaten | aueaten iit, | Sriet, lesee ors | Ststta | Mortseal | Wooea | tonzlera | desiree! | serstecal | aan ora Tits fesse ace | seats, | S| esata) | Terr eas) | aroateer | zens (roa | aos er lea" [ssredoes, | sesh, | | terse | terara, | soostsen | aansboa | Seren Si] ]ieeo es) sisi) | WRSHET | weeowsa) | Teso wes! | tesoleea) | resales] | Tee es] as | ectir, [ames Ges | svete, | aston | tecsea | dees\ane | socoveos | aoesteos | doraiarsy a [rhe féses ims | seatre | irsatsez | taze er | Torajaes | asraiern | aaerioea | ases rest Miers [oer aoe! | corti | 7! | deetiara, | tece awa | aaveleoa! | sesofreal | 2007 eal les!" [aera | seats, | = | tonota | Mesias | teraiseal | aaeeleoe | Sesatrral SHU] ieee ws | seziia) | TOREWORT | wees ane] P Toss ars! | Toss|sosr | Tess [soa] | Toss ars] so | colin) [taes ts | soatia, | orator! | twoara | werwas | ieevfeoa| | textos | wes ias G2 | erts, laser ee | seats, | ‘sozara, | tere eq | rears | soortsea, | tonrisea | coor anal ries fam es | ext | 27° | tea sen | vases | ieraisea | azralees | 2507 any rls" [ees fer [econ | — | "seovra | taeaiaes | inaisoa | astern | bears NOTES] Taal and sree capaly aos, wif dain rn lower mart EInapenton Speman, dona oeapone AIRFLOW CORRECTION FACTORS, MHGE-150 @ 6000 CFM [2832 L/s] MHGE-200 @ 8000 CFM [3776 L/s] a {tat |aorn) ze | ace aoe anna [ozo] ae sen [soo] san em ase] srr] ees | eo [ee ese HorACWaH [oa [oss [asa ase | 100] 108 | ror | 110] 148] cas [ot [ose | o87| 100 | 108 | 108 [107 | 108 SENSIBLE WBR[o7e [ose Loe Loss [too [os [rio [is [120 Lose Lose Lose Lose [roo [roe [roe Dr Do NOTES: 1. Muliply correction factor times grots performance dat, 2, Resulting sensible capacity cannot exceed total capacty. [ ]Designates Metric Conversions 16 McQuay ELECTRICAL HEATER KIT CHARACTERISTICS TauOVOCT MODELS a HEATER KIT HEATING Tamu] _ maxon ruse caacivvxw | capacity — ‘arcu, | onMacR aREAKER NOM, 240V KW. HEATER ONLY INPUT ‘MBH [kW], AMPACITY ‘SIZE Sr graGerOTAL 7, 1512070 ae 5 Roo s00 TEA] | ea Ta 7 a, 15720 05) sa Fiezea | “ra rona so za8) [wate ri05 7 (o, 20(7070 44) 556 rio | Toe mass sony Ti7se iasrs0 7569 0(85/20170 ais 15120 -2008300 (159) [sue 80 35 631 5 69/0110 sa Frezes | ra onee so eae) [Tess oes 43 1 20 (ava 56 io | Toe tas 500 [sony [Toa ‘Bares BOVOET NODELS 7S BST TO TROTRA a a ROT, # 75 158780 05) & 3a 3.20018 30 30 75 [26 20/7070 44) = % 736500140) 70 75 69), 085120170 2 a 3.20019) z e 15 59), 507907108 % aa 6.90018) 3 o Bao a mo 36500) 7 NOTE: As nave wo siagos a capa rr sageheag 8 50% ol apa. ELECTRICAL DATA TABLE TR RANDLER samme aman) RECOMMENDED MNWUNGs] max woToR manne | yoron | tuntun ne si Max, mare) Mina” | RCT | ax vortacerscoror) | (USES. wer [vous | pase tex RUNIN FEET Tray} moma | a0 aoe | ae Tana = ihe | “eo” |S % oe 3 faa 3 ime | gs | iu ee 3 fase 3 inal | 180 | tee | ost | ots sratonaneo aor Tang] peas | 3a] S78? asa Ps a 7 Herma | eo” | Ze ioe % tase % Hens [| ss | Bi tbe 3 esos 8 ae | fess | so} Tes] Baas] as wai = Shit) | “sco” | ge 3 aa 3 nase % sisi) | ss | 30 3 e2 3 Hsa00 3 shen | seem | io | oste | state | sons sromoatan20 sors spear) | aieza | ao} Tosss | eutse | ts was 7 shan | eo" |S a ‘oe 3 nase 8 sieesn_| _sis__| 3 38 Ea g Hed % slaves) | Faeza | a0 | vers? | ooast | ane Taio wes ao Sane | “ao | 3 we | es ‘3 eetes 3 Shree._| srs | oo a se 3 Haase 3 Tie saeg | toeswe | ao] Panes) aaa] a Fos sa free | “eo” | te "3 Hos 3 pases | os | 3 we & 3 nas 8 NOTE: NE.C., CEG. and local codes take precedence over suggested wire ard fuse sizes [1 Designates Metric Conversions McQuay v7 OPTIONAL HEATER KIT ae oro ™ boo See TYPICAL WIRING CONNECTIONS WITH anaes” DUAL CIRCUIT AIR HANDLER, Aud ELECTRIC HEAT & TWO 2% CONDENSING PRY ee UNITS be 4 Buea en "iegeea oes PRR. * PRIN SINGLE PRO. bd gd iti AIR HANDLER ACCESSORIES TASGESSORY | —WODEL—] — sizes — WET WIGHT DESCRIPTION NUMBER USED ON (8S) kg) TRHESTAW—[—O76e0—| — FeO TT Hot Water Colt MXHC-C76W. 150, 200 200 [91] Seaman Pwiiesc74s | “ors 00] Do He-o76s | 1500 Taran [oe [a Fiter Frame Kit MXHF-B76A 150, 200, 117 (53) eau MRE oTe —|~ore ao | — 3 pe crea | “60 B| Te Deaage ~~ [LanG-c7a8 | ars 100 [sim Siiet Gores —| 10.200 [0 Desge ~~ [LMAR-c748 | ors too [ae Penmiet__ wericores [ren 200 [ae vane pox [LBB [ os T00| fs Treat —| 0. ae Tbe Dea | oo —| — TA svete WHEDEDRTA | —O75-100. feworkt — [TuntiEsE0aro [150-20 Here GEoIS | 150.700 NOTE: “Designates °C" o 18 McQuay [ ]Designates Metric Conversions MXHM MIXING BOX AIR HANDLER ACCESSORIES (con't) HOT WATER OR STEAM COILS mxic-c7aw (075,100) Mxne-eras ose mxie-c7ew (150,200) ie cree wxtic-c7aw (075,100) yxHc-c74s wxHe-c7ew (150,200) Nxne-eres PHYSICAL SPECIFICATIONS GROSS COIL PERFORMANCE noma, | EINNED | FINNED ] FACE [ROUTE NOMINAL [NOMINAL BTUR | nowmNAL | VELOGTY Tons | HEIGHT” | LENGTH | AREA | & TuBes Tons iw [STEAM [ WATER] CFuLUsi | “FPN TEREREORETH| teiasri_| aoviovel [sorsa | — 12 ff 15 [52.75}-20 [70.34] | 27 [686] | 48 [1219] | 9.0[.84) 18 — i =. 88) 75(52731_| 485,000 | 375 000_| 6.000 aee2) | 667 STEAM COIL 207034] [ 540,000 | 464 600-| 8.000 8776) | — ase | 1. Enrng ai tomporaie @ 60 a 2: Eniwing steam © 8 PSIG ue 4 Enwmng water © 200°F " crt i on 4. aon vy = SE | | iW il |" | | vghye STEAM COIL DIMENSIONS—INCHES [mm] WODEL[NOMNALTONSEW] A] @ [©]. Te] Fl e[a],s [x]. Tapes: | ou farm | on | om | is | a [ae] tm | am | am pam | oi MXHC-C74 10 [35.17] {230) | (543) | (137) | [81)_| 1381) | (610) | (38) _| (32) | (1308) | (1210) | (71)_| (83) 15 (50.75 sine [aoe [som Pane 2a | as [2 | te | sete] sete | 20 | sie MXHC-C76S 20 [70.34] (230) _|_(7e4)_| (137) | (e1)_| tet) | (gas) | (51) | 138)_| 11519) | 11413) | 71) isa) HOT WATER colL | , ats a HOT WATER COIL DIMENSIONS—INCHES [mm] wooe[NounacTons[ A Te Teo [e[r[e[n[s [x]. @ Tapes, [oe] ao | om Poe | | ae pam | oe] sie | ame | oe | MXHC-C74W) 10 (35.17) (230) | (543) | (1371 | (8) | [381 | t6r0) | 32) | (32) | (1308) | (1210) | (71) (76) TST] aie | aoe | sm Pore | 22] a Pie | He | seve | seve | 2c | a MxHe-c76W 20 (70.34) (230) | (784) | (1371 | (1) | 1610) | tees) | (38) | (38) | (1511) | (1493) | (71) (33) [1 Designates Metric Conversions McQuay 19 AIR HANDLER ACCESSORIES (con't) HOT WATER COILS CURVE 2 HOTWATER COIL CURVE 3 HOTWATER COIL WATER PRESSURE DROP Cou Fao VETO TY FP T ; TTT [a FAO re-t0 TON 2 cncum) | 4 - eerenon |_| iearot cca . nL wrenveioorys |} eg zune teeupmec z "|g 4 iaoeo Ee z° t \ 3, 75-1090 . gL i i \ E +. ge | 3 \ ~ ne = OIL ~ ‘ oa a ‘COM CAPACITY 1000's BTUMIFT: FACE AREA ‘apmiciRcut BASIC FORMULA: TABLE IV etn Curve 2 ratings are based on 200°F entering water and Air Temperature Rise, *F = Crag 20'F temperature drop. For other conditions use the fllow= ing eorreton actors: Water Temperature Drop, °F = —_BTUH_ = s00xGPM ENTERING ENTERING | rector | rewpenarune | FACTOR DROP F m0 74 70 7080 210 tor is tors 00 00 2 +000 iso fe = 8s io = ® 570 HOT WATER COIL SELECTION: ‘Specified: Entering Air Temp. @ 40°F 5000 CFM @ 6000 Ft. Elevation 20°F Entering Water Tomp. @ 36 GPM ‘Select 10 Ton Nominal Ci Face Area =5 Ft Circuits = 12 Determine Coll Performance: From Table | (page 20), Alitude and Temperature Correction Factor = 1.19 Std. OFM = 5000/1.19 = 4202 Face Velocity = 4202/5 = 840 FPM From Curve 2, BTUHIFE = 57,500 oll Capacity = 5 x 58,000 = 287,500 BTUH Water Temp. Drop = 280,000/(500 x 36) = 16.1°F From Table IV, Water Temp. Factor = 1-14 From Table 1V, Water Temp. Drop Factor ‘Total Capacity = 287,500 x 1.14 x 1.015 = 334,570 BTUH From Curve 3, Water Pressure Drop 36 GPM/'2 Circuits = 3 GPM/Circuit = 1.6 FT. HD. From Table I, Alr Side Prossure Drop = .38" HO. 20 McQuay AIR HANDLER ACCESSORIES (con't) STEAM COILS AIRFLOW TABLE! ALTITUDE AND TEMPERATURE CORRECTION FACTOR TABLE ro TALTITUDE IN FEET ABOVE SEA LEVEL vewr, HP [0 | s00 | 1000 | 1800 | 2000 | 2500 | 2000 | 2500 | 4000 | 4500 | so00 | ove | 7000 | e000 | 2000 | 10000 oar ae at ee | ne |e | me [rr | 08 | ae [toe ae | ae | wor [96 [ee | too [400 | 100 | 406 [10a [atop ate [ae | ate [408 [8 | tae | To [400 [tae [tot | +08 [toe [ tte rae ate [ote [aie | t20 125 [100 | tas [amo | a Too [06 [108 [ato fate [ase [ate [aie | a [123 | sas | tae [aa | tae | tae [ae | 18 a0 [ aoe [are [asa [ate | te [420 [2s | tas [tae [a0 [tae [rae | tae [ae [ae | tse EXAMPLE: Determino Equivalent “Standard Ai for use in System Performance Calelation: cil CFM Standard Air = Speciied CEM _ TABLE Gorrecion Factor aun Feet Loss {LiLItLilt 8 |_| 2row-are er Pitch? TUBES NOT WATER AND STEAM Feu FH AIR FRICTION LOSS, INCHES OF WASTER MODELS 7Hsr10 TOM RA. = 500 MODELS 16-20 TON FA. 20.04, 20) 40) Sco oe 700800 STEAM COILS CURVE1 eveA SOR ExPACITY © 1 T rol A gol ttf ty Po rads BL ba a ae €8 3 ” 4 2 «| 4 ge g0 & woh. aL Net 10 1 Sa ‘ol amon wis tunis ce SAA TEMPERATURE OF STEAM AT VARIOUS PRESSURES Tosti ae Peed TFT STB 300) FACE VELOCITY, FP (STANDARD AIR) oo oo 1200 G00 1400 TABLE Il Steam Coll Capacity, factors. sremapa: PSG [FACTOR fare based on 5 PSIG Steam a = Pressure. For other condi- 5 $99 tions use the adjacent cor 2 19. rection factors. s Mt BASIC FORMULA: =“ BTUH Air Temperature Rise, °F = —STUH femperature Rise, °F = SU ‘STEAM COIL SELECTION Specie Steam @ 30 PSIG Entering Air Temp, @ 40°F Dry Bulb ‘5000 CFM @ 6000 Ft. Elevation ‘Select 10Ton Nominal Coil: Face Area =5 Ft" Circuits = 12 Determine Coil Performance: From Table | (page 20), Alftude and Temperature Correction Factor = 1.19 Std. OFM = 5000/1.19 = 4202 Face Velocity = 4202/5 = 840 FPM From Curve 1, STUHIFt = 66,500, Coil Capacty = 5 x 65,000 = 325,000 BTUH From Table Il, Steam Correction Factor = 1.24 Total Coil Capacity = 1.24 x 332,500 = 412,300 BTU Air Tomp. Rise = 403,000/(1.08 x 4202) = $0.85°F From Table Il Air Side Pressure Drop = 38" HO. McQuay 21 AIR HANDLER ACCESSORIES (con't) FILTER RACK ‘The filter rack accessory can be connected directly to the hot water/steam coll accessory. The filer rack accessory is ONLY needed when hot water steam colls are used, MODEL | AIRHANOLER Tan FILTER PRESSURE DROP: ‘GEM a] x 1000 (472) 7 [e] 8] 05 | oF 6) 10] 15 (ea) | iss) No. | SesusEON|A [ae] ¢| > TE] F aim | 26 Jasin) arm fier Bie (1308) (610) (638) |(1203)](505)] (52) ie] 27 | 5% |aove) 2 (1511876) |688)|it4101](775)] 1511 axie-a74a] 078, 100 axie-a7ea] 050, 200 05 | 06 | 70) a2 p35 ty tia) | (22 | (27 | 183) UNIT WITH ACCESSORIES. 7.5 THROUGH 20 NOMINAL TONS [26 THROUGH 70 kW] Le fessi= sa ‘Taos ete my isa 22 MeQuay DOUBLE DEFLECTION DISCHARGE GRILLE NOMINAL ROMNALT Frm] oF THROW o DER ECTON- 9137 (209, foe Sertecrion- arti] ls DEFLECTION 2 fe oon | & DEFLECTION sore (002, foe Dertection ae ia lig SEALECTION. 27 ooo” [OT DEFLECTION- so Le dertecnion- ae. wasn) (fs Sertecrion. te © DEFLECTION <5 7186 (10% foe Bertecrion as 3] las: DEFLECTION 22" (67 [1 Designates Metric Conversions TYPICAL APPLICATION 7.5, 10, 15 AND 20 NOMINAL TONS [26, 35, 53 AND 70 kW] AUXILIARY HEATER KIT ‘AIR HANDLERS. MODELNO. | Sizes USED ON WHHEDE-wA | 075,100 | B01s08T | 2015081 MXHE-CEnG | 150,200 | seror4) | 24670) MIXING BOX ACCESSORY—OPERATING SEQUENCE COOLING SEASON—Thermostat set at “Coo!” and “Fan Allo,” outside air damper goes to "minimum fresh ar” position ‘when cooking thermostat closes, energizing mechanical cool- ing. When cooling thermostat is satisfied, mechanical cooling is de-energized, and outside air damper closes. INTERMEDIATE SEASON—Same as for cooling season, ‘except that cooling thermostat closes, starling indoor blower motor, the enthalpy control, mounted on outside air, deter- mines if “free” cooling or mechanical cooling should be ut lized. If outside air conditions are suitable for cooling, the ‘mechanical cooling remains off and the mixed air controller modulates the damper motor to assume the proper damper position to maintain mixed air setting. If outside conditions are not suitable for cooling, then the dampers go to "minimum fresh air’ position and mechanical cooling is energized. HEATING SEASON—Damper always stays at "minimum fresh air’ position while fan motor is operating. Outside air damper Clases when blower motor is off. “Minimum fresh air position ‘must not allow mixed air temperatures to alr handler below 50°F. [10°C] during heating seasons, (CAUTION: ITIS NOT RECOMMENDED THAT HOT WATER JOR STEAM COILS BE USED WITH THE MIXING BOX ACCESSORY WITHOUT A SUITABLE FREEZE-STAT TO PREVENT THE POSSIBILITY OF FREEZING THE COIL. MIXING BOX [_ ] Designates Metric Conversions TR RANOLER | __ FLANGED DUGT OPENINGS [am] MODEL NO. | sizes USED ON | LENGTH IN. [rm] | WIDTHIN. [mm] [ “x” MXHM-BC74H (075, 100 42 (1067) 16iHe [454] 27 (686) TREC eH | 150,200 —| — dave frees —| — 2atese) [aaa aaa SHER . _ Se oy pm || Jamon | Hessen sme , = VERTICAL APPLICATION was ff | nonzowna. arpuicarion McQuay 23 TYPICAL PIPING RECOMMENDATIONS, INDOOR COIL ABOVE NOTE EAS OS OUTDOOR UNIT OUTDOOR UNIT RE soerae HMUE SOO soRING OnE SOLENOID VALVE cere 6g gugyn SHOULD Be MOUNTED AS CLOEE TOA INDOOR COIL BELOW Rea thne ‘The 7.5 [26 kW] through 20 [70 kW] Air Handlers are designed as two (2) circuit, fll face equal distribution coils. As shipped fom the factory, the suction and liquid lines are dual circuts. Copper fitings are supplied inthe unit to field manifold the suc- tion and liquid ines for single circuit NOTE: The expansion valve bulbs must be secured to the cor. responding suction lines. The circuits are marked accordingly. See illustration under Typical Piping recor ‘mendations for additional information. When dual straight cool condensing units are used refer to the refrigerant piping size charts for the individual condensing unit piping. REFRIGERANT PIPING (see Tabies at Right) The following will be of help in accomplishing a successful installation 1. Size liquid line for no more than 30 PSIG [207 kPal pressure drop. 2. Size suction ines for no more than 2°F (1.1°C] loss which cor responds to approximately 3 PSIG [21 kPal pressure drop. 3. When indoor unit is installed below outdoor unit, do not ‘exceed the recommended vapor line ©.D. This will insure ‘adequate velacties for proper ol retum. 4, Install train rier and sight glass in liquid line. 5, Pitch all horizontal suction lines downward in the direction of, flow for cooling only applications, 6. Locate the outdoor unit and indoor unit as close together as possible to minimize piping runs. 7. A liquid line solenoid installed just ahead of the expansion value is recommended for cooling only applications. Be sure condensing units suitable for pump down. 8, Piping runs between condenser and evaporator not to exceed 150’ [46 mj linear length (80' (27 m] linear length for heat pumps). NOTE: Refer to suction and liquid line pressure drop charts found in condensing unit and remote heat pump Iterature, 24 McQuay CONDENSATE DRAIN PIPING + Consult local codes or ordinaces for specific requirements regard ing condensate drain + Condensate drain is open to atmosphere and must be trapped. ‘Trap must be at least 3 inches [76 mm] deep and made of flexible material or fabricated to prevent freeze-up, + Pitch the drain line at least 1/ inch [6 mm] per foot away from the dain pan, + Do not reduce the drain line size from the connection size pro- vided on the unit + Donnot connect the drain line toa closed sewer ine. PIPING SIZES O75 & 100 wav Ton entMEAR [NE GSEIN tm | Ne ON rm os [100 [075 | 100 SORT Te ae | Set00(r6-s6][ (a) ete) [381 a Tor tsorarae)_[ Warts | setter asl “For cooling only recommendations fo remote heat pump Meratve for piping PIPING SIZES 150 & 200 TaD Ton ene AR, [NE G5EIN mm | Ne ON rm 50 [_200 [60 700 SH | Tore Pee | aT B-t00 ef [9 ta)_| To eat [recent | 0 Tortebpstae— [aerial | eat | aie sa | a EQUIVALENT LENGTH, FT [m] OF STRAIGHT TYPE “L" TUBING FOR NON-FERROUS VALVES AND FITTINGS (RAZED) TUBE SIZE | SOLE-|ayque|SHORT|LONG | TEE | TEE INCHES [mm] wow |ANSLE raoius|RaDIus| LINE eRaNcH| 0.0. | VALVE FLL | ELL | FLOW | FLOW Wa(t3]_| 70 (en]|2e78) a7 (.a]]82 .96]] 1.7759)] 66 20] ‘ietval _| 72 (22)|25 (7.8) 57.71/89 (12i] 23170)| 82125) (18) _| 75 (28]| 2517-6) [65 (.5]|¢5(1-4] 2.9 (88)] 87 (8.0) 7ie(2a) | 78 (o4)| 2818.5) [7.8 (24)|53(18)] 8.711.1)[12.0 (8.7) Twetes)_| 97 (o7i[29 88) [2.7 (0.8]|19(58)] 62(%.8)| 80124) Te (95) [02 [311] 8 10) [a2 [98][2-2167]| 6912 1)|100159) Tela} [115 [95)] 34 (10.4)3.8 2][26 1 78]] 8727120137) Bina) [rar 3) | se (als 2 lfs.a tolfi20 (8 7i|r6.0(43) OPERATING SEQUENCE NOTE: Please refer to specification sheets covering MAWD- condensing units and MPWC- Remote Heat Pumps for operating sequence. GUIDE SPECIFICATIONS Furnish and install as shown on the drawing McQuay Model raw through air handler sultabe for both hor'- Zontal and vertical applications. The entire assembly shall be ULL/C.S.A, listed with the cooling (and heat pump heating) capacity ARI. Certified. DRIVE PACKAGE—A complete drive package shall be factory or field installed. Package shall consist of a 3450 RPM dual vol- age, single phase open drip proof motor or a 3 phase 1750 RPM ‘pen drip proo! internally protected motor, not requiring an exter- nal starter. Variable pitch motor sheave, fixed pitch fan sheave, and belt COILS—Coils shall be fabricated of 3" [10 mm] 0.0. seamless copper tubing expanded into aluminum fins, coreugated with rip- pled edges. There shall be 4 rows of coil with a minimum of 13 fine per inch [25]. All coils shall be submitted to an air pressure test of up to 450 PSIG [3103 kPa] under water after fabrication and dehydrated prior to assembly in unt. Units shal be shipped with a nitrogen holding charge. Allow shall be draw through design providing uniform air distribution across the coll surface, BLOWER, BEARINGS AND SHAFT—Fans shall be a double vwidth, double inlet, forward curve, centvfugal type, statically and dynamically balanced, and constructed of galvanized steel. They shall be mounted on 3/" [19 mm] = 7.5 ton [26 kW] & 10 ton [35 kW}, 1° [25 mm] = 15 ton [53 kW] & 20 ton [70 kW} diameter solid Shafts made of high carson steel, centerless ground and po! ished, supported by resilient mounted sealed bearings. DRAIN PAN—The drain pan shall be manufactured of zinc coated sizel. The pan shall have internally threaded pipe size drain connections and shall be designed to accept condensate in either horizontal or vertical type applications on either side of unit FILTERS—Fiter mounting hardware shall be designed to accept Lup to 2" [51 mm] ters for field roplacement. One inch [25 mm] ‘throw away fers shall be furnished with the unt CABINET—Cabinets shall be manufactured of galvanized steel subjected to multi-stage cleaning and finished with powder coat paint. Units shall have removable service access panels on each side and top. INSULATION—Cabinets shall be insulated with V2" [13 mm] (ot 1¥ [25 mm] for R4.2) by 11/2 pound [.68 kg] density fiberglass insulation coated with neoprene and bonded to the cabinet sur- face with a U.L. approved adhesive. Insulation shall have fire retarding characteristics in accordance with smoke developed rating not to exceed 50 and flame spread rating of 25 per Under- vwiriters Laboratories testing procedures. FACTORY TESTING—In addition to the pre-assembly testing mentioned above, each coil shall be leak tested with a mixture of dy air and R-22 after assembly nto the unit. While under pres- sure, the coll shall be leak tested using an Electronic Halogen Leak Detector ata setting of Vz o2. [14 g] par year sensitivity. ELECTRIC HEATERS—UL and cUL listed electic heater kits shall be available in a wide range of capacities. Alkts shal otfer ‘wo stages of capacity, blower motor controller and single point ‘connection, Heater kis shallbe available for installation directly on the supply fan discharge for either horizontal or vertical application. MIXING BOX—Wixing box accessory shall be available for mixing return air with ouside air before entering the airhandler. The acces- ‘sory shal include both retum and outside air dampers and econ- ‘omizer contels factory mounted, Economizer controls shall include enthalpy and mixed air sensors and damper motors. Mixing box accessory shall be available for installation to the return alr section ofthe air handler for either horizontal or vetical applications, DISCHARGE PLENUM AND GRILLE-Shall be available for vertical application. Discharge grille shall provide manually adjustable double deflection discharge vanes. RETURN AIR GRILLES—Shall be provided for vertical return applications, HOT WATER OR STEAM COILS—Shall be available for field instalation, All colls shall be tested to 300 psi. Coils shall be available for either horizontal or vertical air handler applications. [. 1Designates Metric Conversions McQuay 25 26 McQuay NOTES NOTES McQuay 27 Before proceeding with Installation, refer te Installation Instruetions packaged with each model, as well as complying ‘with all Federal, State, Provincial and Local codes, regulations, and practices. “in keeping with its policy of continuous progress and product improvement, McQuay reserves the right to make changes without notice.”

You might also like