SPECIFICATIONS FOR RESIDENTIAL BUILDING

Sr No. Chapter SSR Item Ref No. Description of an Item Pages


No.
1. Excavation 21.04 BDAI Excavation for foundation in earth, soils 153
of all types, sand, gravel and soft
murum, including removing the
excavated material upto a distance of 50
metres beyond the building area and
stacking and spreading as directed,
dewatering, preparing the bed for the
foundation and necessary back filling,
ramming, watering including shoring
and strutting etc. complete. (Lift from
1.5m to 3.0m) By Mechanical Means.
2. Soling 28.01 BDHI Providing uncoursed rubble masonry of 199
trap/granite/quartzite/gneiss stones in
cement mortar 1:6 in foundation and
plinth of inner walls/in plinth of external
walls including bailing out water
manually, striking joints on unexposed
faces and watering etc. complete
3. Plain 24.06 BDE2 PCC: Providing and laying Cast in situ 175
cement /Ready Mix cement concrete in M20 of
concrete trap/granite/quartzite/gneiss metal for
bed blocks, foundation blocks and such
other items including bailing out water,
Steel centring, formwork,
laying/pumping, compacting,roughening
them if special finish is to be provided,
finishing uneven and honey combed
surface and curing etc. complete. The
Cement Mortar 1:3 plaster is considered
for rendering uneven and honey
combed surface only. Newly laid
concrete shall be covered by gunny bag,
plastic, tarpaulin etc. (Wooden centring
will not be allowed.), with fully
automatic microprocessor-based PLC
with SCADA enabled reversible Drum
Type mixer/concrete Batch mix plant
(Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)
4. Reinforced 25.11 BDF3 Providing and laying in situ/Ready Mix 178
cement cement concrete M-20 of
concrete trap/granite/quartzite/gneiss metal
footing for R.C.C. work in foundations like raft,
strip foundations, grillage and footings
of R.C.C. columns and steel stanchions
etc. including bailing out water, Steel
centering formwork, laying/pumping
cover blocks, compaction and curing
SPECIFICATIONS FOR RESIDENTIAL BUILDING

roughening the surface if special finish is


to be provided (Excluding reinforcement
and structural steel)etc., complete, with
fully automatic microprocessor-based
PLC with SCADA enabled reversible
Drum Type mixer/concrete
Batch mix plant(Pan mixer)etc.,
complete. With fine aggregate (Crushed
sand VSI Grade)
5. Column up 25.31 BDF5 Providing and laying Cast in situ/Ready 179
to ground Mix cement concrete M-20 of
level trap/granite/quartzite/gneiss metal
for R.C.C. columns as per detailed
designs and drawing or as directed
including steel centering, formwork,
coverblocks, laying/pumping,
compaction finishing the formed
surfaces with cement mortar 1:3
of sufficient minimum thickness to give
a smooth and even surface or
roughening if special finish is to be
provided and curing etc. complete.
(Excluding reinforcement and structural
steel). with fully automatic micro
processor based PLC with SCADA
enabled reversible Drum Type
mixer/concrete Batch mix plant(Pan
mixer) etc. complete. With fine
aggregate(Crushed sand VSI Grade)
6. Plinth beam 25.5 BDF5 Providing and laying Cast in situ/Ready 181
Mix cement concrete M-20 of
trap/granite/quartzite/gneiss metal
for R.C.C. beams and lintels as per
detailed designs and drawings or as
directed including steel centering,
formwork, cover blocks,laying/pumping,
compaction and roughening the surface
if special finish is to be provided and
curing etc., complete. (Excluding
reinforcement and structural steel).
With fully automatic microprocessor-
based PLC with SCADA enabled
reversible Drum Type mixer/concrete
Batch mix plant (Pan mixer) etc.,
complete. With fine aggregate (Crushed
sand VSI Grade)
7. Bed 24.06 BDE3 Providing and laying Cast in situ /Ready 175
concrete Mix cement concrete in M20 of
trap/granite/quartzite/gneiss metal
for bed blocks, foundation blocks and
SPECIFICATIONS FOR RESIDENTIAL BUILDING

such other items including bailing out


water, Steel centring, formwork,
laying/pumping, compacting,
roughening them if special finish is to be
provided, finishing uneven and
honey combed surface and curing etc.
complete. The Cement Mortar 1:3
plaster is considered for rendering
uneven and honey combed surface only.
Newly laid concrete shall be covered by
gunny bag, plastic, tarpaulin etc.
(Wooden centring will not be allowed.),
with fully automatic microprocessor-
based PLC with SCADA enabled
reversible Drum Type mixer/concrete
Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed
sand VSI Grade)
8. Reinforced 25.31 BDF5 Providing and laying Cast in situ/Ready 179
cement Mix cement concrete M-20 of
concrete trap/granite/quartzite/gneiss metal
column for R.C.C. columns as per detailed
designs and drawing or as directed
including steel centring, formwork,
cover blocks, laying/pumping,
compaction finishing the formed
surfaces with cement mortar 1:3
of sufficient minimum thickness to give
a smooth and even surface or
roughening if special finish is to be
provided and curing etc. complete.
(Excluding reinforcement and structural
steel). with fully automatic
microprocessor-based PLC with SCADA
enabled reversible Drum Type
mixer/concrete Batch mix plant (Pan
mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)
9. Reinforced 25.50 BDF5 Providing and laying Cast in situ/Ready 181
cement Mix cement concrete M-20 of
concrete trap/granite/quartzite/gneiss metal
beam for R.C.C. beams and lintels as per
detailed designs and drawings or as
directed including steel centering,
formwork, cover blocks,laying/pumping,
compaction and roughening the surface
if special finish is to be provided and
curing etc., complete. (Excluding
reinforcement and structural steel).
With fully automatic microprocessor-
based PLC with SCADA enabled
SPECIFICATIONS FOR RESIDENTIAL BUILDING

reversible Drum Type mixer/concrete


Batch mix plant (Pan mixer) etc.,
complete. With fine aggregate (Crushed
sand VSI Grade)
10. Reinforced 25.7 BDF8 RCC Slab: Providing and laying Cast in 182
cement situ/Ready Mix cement concrete M-20
concrete of trap/granite/quartzite/gneiss metal
slab for R.C.C. slabs and landings as per
detailed designs and drawings including
steel centering, formwork, cover blocks,
laying/pumping, compaction finishing
the formed surfaces with cement mortar
1:3 of sufficient minimum thickness to
give a smooth and even surface or
roughening if special finish is to be
provided and curing etc. complete,
(Excluding reinforcement and structural
steel). With fully automatic
microprocessor-based PLC with SCADA
enabled reversible Drum Type
mixer/concrete Batch mix plant (Pan
mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)
11. Brick 27.16 BDG Providing Autoclaved Aerated Concrete 198
masonry Block masonry of conforming to IS:2185
(Part3)-1984 in extra fine jointing mortar
of fixoblock of Ultra Tech or equivalent
in Half brick thick wall including striking
joints, raking out joints and scaffolding
etc., Complete. (The test shall be carried
out conforming to IS:6441 (Part I) -
1972)
12. flooring
13. skerting 33.29 BDM Providing Mirror polishing to Kota Stone 216
including using all necessary stones and
equipment’s cleaning, washing etc.
complete. For Skirting.
14. daddo 33.27 BDM13 Providing and laying ceramic tiles having 215
size 30cmx60cm, confirming to
corresponding I.S. for dado and skirting
in required position with readymade
adhesive mortar of approved quality on
plaster of 1:2 cement mortar including
joint filling with white/color cement
slurry cleaning curing etc. complete.
15. Ceiling 32.34 BDL Providing and applying Two coats of wall 212
plaster care Putty on plastered surface and
Ceiling and Walls to prepare surface
even and smooth of approved make
etc., complete.
SPECIFICATIONS FOR RESIDENTIAL BUILDING

16. Inside 32.01 BDL1 Providing internal cement plaster 6mm 209
plaster thick in a single coat in cement mortar
1:4 without neeru finish to concrete
surface in all positions including
scaffolding and curing etc., complete.
17. Out side 32.12 BDL8 Providing rough cast cement plaster 209
plaster externally in two coats to concrete, brick
or stone masonry surfaces in all
positions with base coat of 12 to 15 mm
thick in C.M. 1:4 and rough cast
treatment 12 mm thick in proportion
1:11/2:3 including scaffolding and
fourteen days curing complete
18. Inside paint 36.12 BDP6 Providing and applying plastic emulsion 227
paint of approved colour and shade to
old and new surfaces in one coat
including scaffolding, preparing the
surfaces (excluding the priming coat)
etc., complete.
19. Outside 36.12 BDP6 Providing and applying plastic emulsion 227
paint paint of approved colour and shade to
old and new surfaces in one coat
including scaffolding, preparing the
surfaces (excluding the priming coat)
etc., complete.
20. windows
W 39.26 BDT57 Providing and fixing collapsible steel 249
gate inone/two leaves with hot rolled
vertical channels of 18x9x3 mm
minimum size, crossings of M.S.flats of
size 18x5mm T or E section for runner of
minimum 40x6 mm size for flange, M.S.
flat for top runner of minimum size
40x12 mm with
roller wheels confirming to grade
F.G.150 fittedwith snap headed rivets of
minimum size 6 mm max. spacing of
vertical channels be 100 mm enclosed
gate position and clear space of 150
mm between two sets of crossings with
hold fasts, stoppers, spaces, handles,
locking arrangement and one coat of red
lead primer and oil painting etc.
complete. (I.S. 105211983).
W1 39.17 BDT43 Providing and fixing Country cut teak 247
woodwindows with double leaf 25 mm
thick planke shutters without ventilators
as per detailed drawings including
stainless steel fixtures and fastenings
and finishing the wood work with
SPECIFICATIONS FOR RESIDENTIAL BUILDING

oilpainting 3 coats etc. complete


W2 39.17 BDT43 Providing and fixing Country cut teak 247
woodwindows with double leaf 25 mm
thick planke shutters without ventilators
as per detailed drawings including
stainless steel fixtures and fastenings
and finishing the wood work with
oilpainting 3 coats etc. complete
21. DOORS
D1 39.13 BDT Providing and fixing factory made 246
panelled doorshutter in single leaf 35
mm thick style and rail without
ventilator with CCTW panels 12 mm
thick including wrought iron hold fast
and stainless steel fixtures with oil
painting 3 coats etc. complete
MD 39.05 BDT11 Providing and fixing Country cut teak 245
woodsingle leaf panelled door shutter
without fanlight and 25 mm thick as per
drawing consisting of T.W. to prail size
100 mm x 25 mm and bottom lock rail
200 mm x 25 mm insert pannel 12 mm
thick commercial ply faced T.W. particle
boardwith phenol formaldehyde
synthetic resin(Generally confirming to
ISI 3097)excludingframe, including
stainless steel fixture andfastening and
T.W. beading to junctions ofpanelled
inserts and as instructed by the Engineer
in charge including 3 coats of oilpainting
etc. complete.
D2 39.09 BDT34 Providing and fixing solid core flush door 246
shutter in single leaf 32 mm thick
decorativetype of exterior grade as per
detailed drawingsapproved face veneers
3 mm thick on both facesor as directed,
all necessary beads, mouldings and
lipping, wrought iron hold fasts,
chromium plated fixtures and
fastenings, with brass mortiselock,
chromium plated handles on both
sides,and finishing with French Polish
etc. complete.
22. Damp proof 31.01 BDJ2 Providing and laying dampproof course 205
course 50 mm thick in M20 cement concrete
layer and bitumen/using cement with
water proofing compound curing, form
work etc., complete.