Cat SR4B HV

Generators

PRODUCT INFORMATION
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Generator Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Features & Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5

Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10

Terminal Box Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-24

Additional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-26

Automatic Voltage Regulator — KCR 760. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27-28

Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Temperature Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Optional Attachments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-37

1
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

SR4B HV GENERATORS
In January 1997 Caterpillar introduced the new flexibility of LHS and RHS cable entry but now
world-class Cat SR4 HV (High Voltage) include top or bottom cable entry. The brushless
generator for use with the 3500 series engines excitation system has been redesigned to allow
in standby, prime, and continuous applications. easy access to the rotating rectifiers if
Initially, the SR4 HV product line offered replacement is necessary. Additional design
seven frame sizes, and expanded to ten frame enhancements have been incorporated to
sizes in July 1998. With the introduction of the improve the overall package size.
SR4B HV product line, eleven new frame sizes
The generators are designed to be frequency
will be offered: 2410, 2420, 2430, 2440, 2450,
specific, and the performance is optimized for
2460, 2470, 2480, 2810, 2820, and 2830. The
the operating frequency. This means that 50 Hz
table on page 3 indicates the new frames.
generators are designed specifically for 50 Hz
The SR4B HV generators have been operation and that 60 Hz generators are
specifically redesigned to provide a more designed specifically for 60 Hz operation. The
flexible and maintainable product in the field. performance data is available in Technical
The new terminal box will allow the same Marketing Information (TMI).

2
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

SR4B HV GENERATORS
Generator Frames
Frame Size Arrangement Number
50 Hz 50 Hz 60 Hz 60 Hz
4 Pole 6300 Volts 10 000 Volts 6300 Volts 12 470 Volts
6600 Volts 10 500 Volts 6600 Volts 13 200 Volts
6900 Volts 11 000 Volts 6900 Volts 13 800 Volts
2410 160-1362 160-1342 160-1322 160-1302
2420 160-1364 160-1344 160-1324 160-1304
2430 160-1366 160-1346 160-1326 160-1306
2440 160-1368 160-1348
2450 160-1370 160-1350 160-1328 160-1308
2460 160-1372 160-1352 160-1330 160-1310
2470 160-1374 160-1354 160-1332 160-1312
2480 160-1376 160-1356 160-1334 160-1314
2810 160-1336 160-1316
2820 160-1378 160-1358 160-1338 160-1318
2830 160-1380 160-1360 160-1340 160-1320

3
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

FEATURES & BENEFITS


Stator Construction Bearings
• Form wound with mica between turns • Anti-friction, bracket mounted, regreasable
• Mica between conductor and ground • Exciter end bearing is insulated to eliminate
shaft circulating current
• Insulation: class F, Vacuum Pressure
Impregnated (VPI) with epoxy resin • 2500 frames: deep groove ball bearing
encapsulation
• 2900 frames: split roller bearings
• Compact and rugged design
Drive Configuration
• Fabricated bar and plate steel construction
• Two bearing close coupled
Rotor Construction
Brushless Excitation System
• Salient pole type
• Fully laminated Permanent Magnet (PM) Generator
• Insulation: class F, VPI with epoxy resin
Automatic Voltage Regulator (AVR)
encapsulation
• KCR-760 with +/- 0.5% accuracy
Generator Enclosure • Three-phase sensing
• IP23 Open Drip Proof (ODP) guarded
• Cross-current compensation circuit for
parallel operation
Terminal Box
• Volts per Hertz regulation with
• Fabricated construction with Modular design
underfrequency set points at 59.5 Hz for
allowing RH or LH, top or bottom cable
60 Hz applications and 49.5 Hz for 50 Hz
entry
applications
• Sized to accommodate four CTs
Temperature Detectors
• DIN rail mounted terminal blocks
• Six 100 ohm platinum Resistance
• Meets IP44 protection level
Temperature Detectors (RTDs) installed in
stator (two per phase)
Terminals
• One 100 ohm platinum RTD installed in each
• Six wire, wye connected, utilizing four stand-
bearing
off terminal connectors

4
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

FEATURES & BENEFITS


Space Heater Optional Features
• 120/240 volts, single phase 2 kW • Cross-Current Compensation Current
Transformer (CCCT), mounted and wired in
Overspeed Capability generator main lead outlet box
• 125% • Current Transformers (CTs) shipped loose for
mounting in switchgear
High Efficiency
• Differential Current Transformers (DCTs),
mounted and wired in the generator main
Excellent Motor Starting Capability
lead outlet box
Optimum Pitch • Six lead, six terminal configuration (three-
phase leads located on the opposite side of
Serviceability the generator as the three neutral leads)
• Easy access to all serviceable parts • Top cable entry
• Service parts available in Morton Parts • Automatic voltage regulator with 2:1 volts-
System per-hertz regulation
• Service intervals match those of 3500 engine • Digital voltage regulator, Basler DECS125-15
• VAR/power factor controller
Rewindable on Site
• Radio Frequency Interference (RFI)
• Unique B stage insulation technology
suppression
Standard Caterpillar Warranty • Min/max excitation limiter
• Auto-manual control, Basler models
MVC-108, 112, or 300
• Diode fault detector
• Motor operated potentiometer
• Thermostat for space heater
• Air intake filters with an air differential
pressure switch

5
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

COMPONENTS
Stator Construction
The stator frame has fabricated bar and steel Winding overhang on the stator is insulated
plate construction. It is machined to tolerance between phases. Surge ropes are used to
to provide alignment with the rotor. Non- support the winding overhang. The windings
oriented, silicon steel laminations with core- are braced to withstand single phase and three
plated insulation on both sides are used to phase fault conditions.
reduce core loss and temperature rise in the All insulation materials used in the stator have
machine and to improve efficiency. The a minimum temperature rating of 155° C
stacked laminations are skewed to reduce (Class F) per IEEE Std 1. The windings are of
harmonic distortion caused by the slots, and form coil construction. Turn-to-turn testing is
held under pressure with clamping plates performed on all stator windings prior to
without welding on the laminations. impregnation.
The complete stator is processed in a Vacuum
Pressure Impregnation (VPI) chamber.
Encapsulation of the stator is accomplished
with a two-part epoxy system. The epoxy resin
is held within a groundwall tape made of
woven glass fabric with mica paper, which has
450 to 600 volts/mil of electrical strength. The
proper stoichiometric balance of the epoxy
resin and hardener is accomplished during the
VPI cycle. To ensure thorough penetration of
resin into the windings, the vacuum pressure
cycle is below 200 microns, and the air
pressure cycle is greater than 90 psi. A high-
potential test is conducted on the stator after
impregnation per IEEE Std 115.

6
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

COMPONENTS
Rotor Construction
The rotor is a fully laminated, salient pole All insulation materials used in the rotor have
type. Low resistance amortisseur bars are a minimum temperature rating of 155° C
inserted through slots in the field poles and (Class F) per IEEE Std 1. The poles are of a
brazed/welded to a continuous shorting ring to layer wound construction.
complete the damping circuit. Cooling fans are
The complete winding and rotor pole assembly
an integral part of the rotor assembly. The rotor
is processed in a VPI chamber. Encapsulation
has accessible provisions for bolt-on balancing
of this assembly is accomplished with a
weights.
thixotropic, single component epoxy resin. To
ensure thorough penetration of resin into the
windings, the vacuum pressure cycle is below
5000 microns, and the air pressure cycle is
greater than 90 psi. A high-potential test is
conducted on the rotor after impregnation per
IEEE Std 115.
The alternator is capable of withstanding,
without adverse effects, overspeed of
125 percent of synchronous speed for the
duration of one minute. The rotor is
dynamically balanced. The vibration
displacement does not exceed 0.0508 mm
peak-to-peak.

7
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

COMPONENTS
Brushless Excitation System Permanent Magnet (PM) Generator
The Brushless Excitation System (BES) is The PM generator provides two major
comprised of four individual components: functions to the BES. The primary function is
exciter rotor, Permanent Magnet (PM) rotor, power to the voltage regulator. The secondary
rectifier assembly, and exciter/PM stator function is to provide three-phase short circuit
assembly. sustaining current for a minimum of
250 percent for 50 Hz applications and
The exciter rotor, PM rotor, and rectifier
300 percent for 60 Hz applications, for ten
assembly rotate together with the alternator
seconds at the generator terminals. The
rotor as a complete assembly on one shaft. The
percentages listed are based on prime ratings
exciter/PM stator is the stationary component
of the generators.
that is mounted directly to the generator end
bracket. The BES is compatible with the
Rectifier Assembly
complete solid-state type automatic voltage
regulator that is supplied with the generator. The rectifier assembly is directly connected to
the main rotating field and provides three-
The SR4B HV generator has had the entire
phase, full wave rectified power for excitation.
BES redesigned for ease of maintenance.
The rectifier assembly consists of six rectifiers,
Typical BES configurations have had the PM
three standard polarity and three reverse
out-board in relationship to the exciter and
polarity; a surge protector; and two heat sinks.
rectifier assembly. The SR4B HV
configuration brings the rectifier assembly out-
Exciter/PM Stator Assembly
board in relationship to the exciter armature
and PM. Simply removing the exciter end The exciter and PM winding assemblies are
cover gives access to the individual rectifiers. mounted in one common frame. Both receive
the same high quality VPI with epoxy resins as
Exciter Rotor (Armature) the main stationary field. The exciter/PM stator
assembly leads are terminated at terminal strips
The exciter rotor is a high frequency, brushless
located in the low voltage terminal box which
alternator. The exciter armature windings
can be found at the exciter end of the main
receive the same high quality VPI with epoxy
lead outlet box.
resins as does the main rotating field.

8
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

COMPONENTS
2800 Frame

Exciter Rotor Exciter and PM Assembly

Exciter/PM Stator

2400 Frame

Exciter and PM Rotor Exciter, PM, and Rectifier Assembly

Exciter/PM Stator

9
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

COMPONENTS
Main Outlet Box all tinned copper standoff terminal-type, all
suitable for the termination of high voltage
The Main Outlet Box (MOB) is mounted on cables. The busbars are drilled for terminal
the top of the generator nearest the exciter end. lugs having two holes on the phase busbars
There are two purposes of the MOB. The first and four holes on the neutral busbar. The
is safety — the MOB provides a barrier against redesigned EB for the SR4B HV provides the
accidental contact with the power leads. The customer with flexibility to change location for
second is environmental protection of the leads incoming cables from RHS to LHS and top to
and mounted attachments. The MOB will be bottom cable entry.
large enough to accommodate a maximum of
four current transformers and designed to meet Low Voltage Connection Box
Ingress Protection (IP) 44, which means it can
prevent entry of splashing water and solid The Low Voltage Connection Box (LVCB) is
objects bigger than one millimeter in size. within the MOB on the exciter end. the LVCB
design provides fast, easy, and safe customer
Extension Box connection from the outside of the MOB for all
low voltage features. Both standard features
The Extension Box (EB) is just that — an (bearing RTDs, stator RTDs, space heater,
extension of the MOB. Other names for the EB exciter field, and PM field) and optional
may be the Cable Entry Box (CEB) or features (thermostat, differential CTs, and air
Terminal Box (TB). The purpose of the EB is filter differential pressure switch) have
connection to the customer’s incoming cables. terminals provided.
The EB includes four rigidly mounted busbars
— three phase busbars and one neutral busbar,

10
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Standard — Right-Hand-Side Facing Exciter End with Bottom Cable Entry

2400 Frame

2800 Frame

11
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Optional — Left-Hand-Side Facing Exciter End with Bottom Cable Entry

2400 Frame

2800 Frame

12
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Optional — Right-Hand-Side Facing Exciter End with Top Cable Entry

2400 Frame

2800 Frame

13
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Optional — Left-Hand-Side Facing Exciter End with Top Cable Entry

2400 Frame

2800 Frame

14
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Optional — Six Lead, Six Terminal
(Three phase leads on right-hand-side facing exciter end, three neutral leads on left-hand-side
facing exciter end and bottom cable entry)

2400 Frame

2800 Frame

15
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Optional — Six Lead, Six Terminal
(Three phase leads on left-hand-side facing exciter end, three neutral leads on right-hand-side
facing exciter end and bottom cable entry)

2400 Frame

2800 Frame

16
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Optional — Six Lead, Six Terminal
(Three phase leads on right-hand-side facing exciter end, three neutral leads on left-hand-side
facing exciter end and top cable entry)

2400 Frame

2800 Frame

17
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Optional — Six Lead, Six Terminal
(Three phase leads on left-hand-side facing exciter end, three neutral leads on right-hand-side
facing exciter end and top cable entry)

2400 Frame

2800 Frame

18
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Differential Current Transformers (DCT) and Cross-Current Compensation
Current Transformer (CCCT) Installed

2400 Frame

2800 Frame

19
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Stand-Off Terminals

PHASE BUSBAR

NEUTRAL BUSBAR

20
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Low Voltage Connections

21
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Strip Assembly — Resistor

Ø 5.1 x 12.4
2 HOLES

END PLATE

R1
W1
C1
R2
W2
C2
R3
W3
C3
R4
MARKER W4
C4 SEPARATOR
R5
W5
C5
R6 TERMINAL BLOCK
W6
C6
BGR1
BGW1
BGC1
BGR2
BGW2
BGC2

END STOP

RAIL

22
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Strip Assembly — Transformer

Ø 5.1 x 12.4
2 HOLES

END PLATE
JUMPER

CB1
CB2
MARKER DA1
DA2
DB1 SEPARATOR
DB2
DC1
DC2
AS1
TERMINAL BLOCK
AS2
AS3

END STOP

RAIL

23
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TERMINAL BOX CONFIGURATIONS


Strip Assembly — Main

Ø 5.1 x 12.4
2 HOLES

END PLATE
JUMPER

H1
H2
H3
H4
1
2
3 SEPARATOR
MARKER 4
PM1
PM2
PM3
PM4
TERMINAL BLOCK
GND
F1
F2
GND
GROUND BLOCK

END STOP

RAIL

24
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

ADDITIONAL FEATURES
Drive Configuration Temperature Detectors
The alternator is of the independent two- The stator includes six 100 ohm platinum
bearing design type. It has a shaft extension RTDs, two per phase. Each bearing includes
and close coupled adapter suitable for direct one 100 ohm platinum RTD.
connection to the standard SAE 00 housing of
the engine. Routine Tests
All alternators are given standard factory
Bearing Design
routine tests to ensure that they are free of
2800 Frames mechanical and electrical defects. The tests are
The bearings are a self-aligning, regreasable, conducted in accordance with IEEE-115,
split cylindrical roller bearing design. The NEMA MG-1, IEC34, BSI 4999 and
bearings are serviceable without any need to MIL-STD 705 standards.
either move the alternator from the base or
disconnect the coupling from the engine. The Standards
bearing at the exciter end is insulated to
The generator conforms to the applicable parts
prevent circulating currents.
of the following standards:
2400 Frames
• NEMA MG1-22, motors and generators
The bearings are of a regreasable, single row,
ball bearing design. The bearing at the exciter • IEEE 43, recommended practice for
end is insulated to prevent circulating currents. insulation testing of large AC rotating
machinery
Grounding Pads
• IEC 34-1, rotating electrical machines
Two non-corrosive stainless steel grounding
• BSI 4999, specifications for generator
pads are welded to each alternator. The pads
requirements for rotating electrical machines
are located diagonally opposite each other.
• CSA C22.2-100 Designation ABL3
• EGSA 101P
• ISO 8528-3

25
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

ADDITIONAL FEATURES
Rewindable on Site
Caterpillar has a new procedure that provides alternative method of manufacturing.
an alternate method to rewind 5 kV to 15 kV Replacement VPI windings which are fully
generators in field. This new procedure is equivalent to conventionally produced VPI
called B stage insulation technology which windings can thus be installed on-site in the
gives the advantage of post-impregnated field, if necessary. The table below shows the
windings without a full immersion VPI process differences in the process steps between the
on wound stators. Pre-impregnated, partially conventional and alternate methods.
cured coils are the key elements in this

Conventional vs. Alternate Method


Process Step Conventional VPI Winding Alternate Method VPI Winding
1 Manufacture Coils Manufacture Coils
2 Insulate Coils Insulate Coils
3 Install Coils Vacuum Pressure Impregnation
of coils, partially cure
4 Make Connections, Install Coils
Lash and Block
5 Vacuum Pressure Make Connections,
Impregnation of stator Lash and Block
6 Cure Cure

26
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

AUTOMATIC VOLTAGE REGULATOR —


KCR 760
Specifications
Regulation Volts per hertz with underfrequency protection
Regulation Accuracy ±0.5% maximum over full range of generator loading and
±5% frequency variation
Sensing 3 phase sensing
Protection Underfrequency protection standard
Break Points
59.5 Hz for 60 Hz systems
49.5 Hz for 50 Hz systems
Regulator Response Within 17 milliseconds
Power Dissipation Less than 50 watts at maximum continuous rating, plus 10 watts
if paralleling is used
Burden 6 VA maximum on sensing terminals
Thermal Stability Within 0.5% over 40° C ambient temperature change
Operating Temperature -40° C to +60° C
Storage Temperature -60° C to +85° C
Shock Tested to withstand up to 20 g’s in each axis
Vibration Tested to withstand 1.2 g’s from 6-26 Hz,
0.091 mm double amplitude from 26-52 Hz,
5 g’s from 53-200 Hz
Construction Chassis is steel with welded seams, zinc plated per QQ-Z-325
Type II Class 2. Circuit board is silicon resin conformal coated
Dimensions 216 mm x 292 mm x 116 mm (8-1/2 in. x 11-1/2 in. x 4-9/16 in.)
Weight 6.4 kg (15 lbs) approximately

Features
• Adjustable stabilizing network • Tested for vibration and shock
• Solid state flashing circuit, no moving parts • Paralleling standard
or arcing contacts
• Optimized for Permanent Magnet (PM)
• All silicon semiconductors generator power
• Fuse protected

27
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

AUTOMATIC VOLTAGE REGULATOR —


KCR 760

122.2
171.5

91.9
44.4
127

03

01
8.6
02 02 02

STABILITY

PARALLEL RANGE

E1 E2 E3 F+ F- R1 R2 A P1 P2 CT CT1CT5 FUSE

274.6
285

ø 7.1
03

01

4 HOLES

28
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

CONNECTION DIAGRAM
LOOSE CONTROLS
ROTATING
RECTIFIER VR
ASSEMBLY KCR – 760
CT CT CT
E1 E2 E3 F- F+ R1 R2 A P1 P2 1 5
EXCITER
EXCITER FIELD ARMATURE
(STATIONARY) (ROTATING)
CB2 CCCT
CB1 LEADS

X X PM4
X X PM
1 1
PM1 LEADS
(REAR VIEW)
VAR
H H H H F2
1 1 EXCITER
GENERATOR F1 LEADS
MANIFOLD
(ROTOR)
ST CSI
120 V
OUTLET BOX SECONDARY

N N

4 1 ØA
TO
LOAD
5 GENERATOR 2 ØB
CCCT
6 3 ØC

240 V

PMC
SPACE
HEATER
120/240 VOLT

1 2 3 4
H4

H1 H2 H3 H4 PM1 PM2 PM3 PM4 F1 F2 CB1 CB2 DA1 DA2 DB1 DB2 DC1 DC2 AS1 AS2 AS3
SH SPARE PMS FIELD CCCT OPTIONAL DCT OPT. AS
JUMPER DIN RAIL
DIN RAIL

HEATER HOOK-UP RESISTANCE TEMPERATURE DETECTORS OPPOSITE


(EMBEDDED IN GENERATOR STATOR) DRIVE DRIVE
ØA ØB ØC ØA ØB ØC BEARING BEARING
RTD1 RTD2 RTD3 RTD4 RTD5 RTD6 RTD RTD

H1 H2 H3 H4
120 V

SH

R1 W1 C1 R2 W2 C2 R3 W3 C3 R4 W4 C4 R5 W5 C5 R6 W6 C6 BGR1BGW1 BGC1 BGR2 BGW2 BGC2


240 V

H1 H2 H3 H4
TD1 TD2 TD3 TD4 TD5 TD6 ODTD DTD
SH
PHASE A PHASE B PHASE C R - RED LEAD
TD1 TD2 TD3 W - WHITE LEAD
TD4 TD5 TD6 C - WHITE DIN RAIL

LEGEND
CCCT – PARALLELING CURRENT TRANSFORMER ODTD – OPPOSITE DRIVE END TEMPERATURE DETECTOR
ST – SENSING TRANSFORMER DCT – DIFFERENTIAL CURRENT TRANSFORMER
VAR – VOLTAGE ADJUST RHEOSTAT AS – AIR FILTER SWITCH
CSI – CUSTOMER SUPPLIED AND INSTALLED PMS – PERMANENT MAGNET STATOR
TD – TEMPERATURE DETECTOR SH – SPACE HEATER

29
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

TEMPERATURE DETECTORS
Resistance Temperature Detectors Recommended RTD Settings
(RTDs)
Condition Stator Bearing
• Type: Platinum
160.35 ohms 133.45 ohms
Alarm
• Resistance: 100 ohms @155° C @ 85° C
• Temperature: 0° C 164.15 ohms 137.33 ohms
Shutdown
• Red – White: Temperature Sensing Element @165° C @ 95° C

• White – White: Lead Resistance


Compensation

30
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

OPTIONALATTACHMENTS
Cross-Current Compensation Current Transformers (CCCT) 15 kV Class
Technical Requires
One CT installed on phase B lead in generator 2400 or 2800 frame generator —
terminal box. ANSI Class: T200, Knee Point: 10 000/10 500/11 000 Volts 50 Hz or
135 V, Error @ 25 VA: 0.14%. Used for cross 12 470/13 200/13 800 Volts 60 Hz
current compensation for parallel operation.
CCCT, 40:5 Ratio 22 kg
Refer to Full Load Amperes at 0.8 Power
CCCT, 50:5 Ratio 22 kg
Factor and Recommended CT Ratio table in
CCCT, 75:5 Ratio 22 kg
the rating section of the price list for
CCCT, 100:5 Ratio 22 kg
recommended CT ratio.
CCCT, 150:5 Ratio 22 kg
CCCT, 200:5 Ratio 22 kg

Cross-Current Compensation Current Transformers (CCCT) 8.7 kV Class


Technical Requires
One CT installed on Phase B lead in generator 2400 or 2800 frame generator —
terminal box. ANSI Class: T100, Knee Point: 6300/6600/6900 Volts 50/60 Hz
100 V, Error @ 25 VA: 0.18%. Used for cross-
CCCT, 75:5 Ratio 14 kg
current compensation for parallel operation.
CCCT, 100:5 Ratio 14 kg
Refer to Full Load Amperes at 0.8 Power
CCCT, 150:5 Ratio 14 kg
Factor and Recommended CT Ratio table in
CCCT, 200:5 Ratio 14 kg
the rating section of the price list for
CCCT, 300:5 Ratio 14 kg
recommended CT ratio.

31
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

OPTIONALATTACHMENTS
Differential Current Transformers (DCT) 15 kV Class
Technical Requires
Three sets of two CTs, one of each set installed 2400 or 2800 frame generator —
in generator terminal box on neutral leads and 10 000/10 500/11 000 Volts 50 Hz or
one shipped loose for customer installation. 12 470/13 200/13 800 Volts 60 Hz
ANSI Class: T200, Knee Point: 135 V, Error
DCTs, 40:5 Ratio 132 kg
@ 25 VA: 0.14%. Used for differential
DCTs, 50:5 Ratio 132 kg
protection. Refer to Full Load Amperes at 0.8
DCTs, 75:5 Ratio 132 kg
Power Factor and Recommended CT Ratio
DCTs, 100:5 Ratio 132 kg
table in the rating section of the price list for
DCTs, 150:5 Ratio 132 kg
recommended CT ratio.
DCTs, 200:5 Ratio 132 kg

Differential Current Transformers (DCT) 8.7 kV Class


Technical Requires
Three sets of two CTs, one of each set installed 2400 or 2800 frame generator —
in generator terminal box on neutral leads and 6300/6600/6900 Volts 50/60 Hz
one shipped loose for customer installation.
DCTs, 75:5 Ratio 82 kg
ANSI Class: T100, Knee Point: 100 V, Error @
DCTs, 100:5 Ratio 82 kg
25 VA: 0.18%. Used for differential protection.
DCTs, 150:5 Ratio 82 kg
Refer to Full Load Amperes at 0.8 Power
DCTs, 200:5 Ratio 82 kg
Factor and Recommended CT Ratio table in
DCTs, 300:5 Ratio 82 kg
the rating section of the price list for
recommended CT ratio.

32
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

OPTIONALATTACHMENTS
Current Transformers (CTs) 15 kV Class
Technical Requires
Identical to installed CCCT or DCT having 2400 or 2800 frame generator —
same ratio and voltage class. One transformer 10 000/10 500/11 000 Volts 50 Hz or
shipped loose. ANSI Class: T100, Knee Point: 12 470/13 200/13 800 Volts 60 Hz
100 V, Error @ 25 VA: 0.18%. Refer to Full
Current Transformer, 40:5 Ratio 22 kg
Load Amperes at 0.8 Power Factor and
Current Transformer, 50:5 Ratio 22 kg
Recommended CT Ratio table in the rating
Current Transformer, 75:5 Ratio 22 kg
section of the price list for recommended CT
Current Transformer, 100:5 Ratio 22 kg
ratio.
Current Transformer, 150:5 Ratio 22 kg
Current Transformer, 200:5 Ratio 22 kg

Current Transformers (CTs) 8.7 kV Class


Technical Requires
Identical to installed CCCT or DCT having 2400 or 2800 frame generator —
same ratio and voltage class. One transformer 6300/6600/6900 Volts 50/60 Hz
shipped loose. ANSI Class: T100, Knee Point:
Current Transformer, 75:5 Ratio 14 kg
100 V, Error @ 25 VA: 0.18%. Refer to Full
Current Transformer, 100:5 Ratio 14 kg
Load Amperes at 0.8 Power Factor and
Current Transformer, 150:5 Ratio 14 kg
Recommended CT Ratio table in the rating
Current Transformer, 200:5 Ratio 14 kg
section of the price list for recommended CT
Current Transformer, 300:5 Ratio 14 kg
ratio.

33
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

OPTIONALATTACHMENTS
Optional Voltage Regulators — Removes Standard KCR-760
Automatic Voltage Regulator Digital Voltage Regulator
2:1 KCR-760 — 50 Hz 0 kg DECS 125-15 — 60 Hz 9 kg
Shipped loose Shipped loose
• Technical – Provides 2 Volts/Hz voltage • Technical — Digital Excitation Control
regulation when generator voltage drops System. Gives adjustable regulation when
below normal constant load operating range, generator drops below normal constant load
allowing generator set to recover from large operating range, allowing generator set to
block loads. recover from large block loads. Has VAR/PF
• Requires — 400 or 2800 frame generator control and minimum/maximum excitation
• Cannot be used with — Digital voltage limiter.
regulator • Requires — 2400 or 2800 frame generator
for 60 Hz applications only
Automatic Voltage Regulator
• Cannot be used with — VAR/PF controller
2:1 KCR-760 — 60 Hz 0 kg
or min/max excitation limiter
Shipped loose
• Technical — Provides 2 Volts/Hz voltage Digital Voltage Regulator
regulation when generator voltage drops DECS 125-15 — 50 Hz 9 kg
below normal constant load operating range, Shipped loose
allowing generator set to recover from larger • Technical — Digital Excitation Control
block loads. System. Gives adjustable regulation when
• Requires — 2400 or 2800 frame generator generator drops below normal constant load
• Cannot be used with — Digital voltage operating range, allowing generator set to
regulator recover from large block loads. Has VAR/PF
control and minimum/maximum excitation
limiter.
• Requires — 2400 or 2800 frame generator
for 50 Hz applications only
• Cannot be used with — VAR/PF controller
or min/max excitation limiter

34
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

OPTIONALATTACHMENTS
Other Options for High Voltage Generators
VAR/Power Factor Controller — RFI Suppression on KCR-760 2V/Hz —
50 Hz 6 kg 60 Hz 21 kg
Shipped loose • Technical — Adds shielding to KCR-760
• Requires — 2400 or 2800 frame generator voltage regulator to reduce RF interference.
• Cannot be used with — RFI suppression • Requires — 2400 or 2800 frame generator
• Cannot be used with — Optional voltage
VAR/Power Factor Controller —
regulators
60 Hz 6 kg
Shipped loose Min/Max Exciter Limiter
• Requires — 2400 or 2800 frame generator EL200 10 kg
• Cannot be used with — RFI suppression Shipped loose
• Technical — Controls field excitation within
RFI Suppression on KCR-760 1V/Hz — operating limits of generator
50 Hz 21 kg
• Requires — 2400 or 2800 frame generator
• Technical — Adds shielding to KCR-760
• Cannot be used with — RFI suppression
voltage regulator to reduce RF interference.
• Requires — 2400 or 2800 frame generator Auto Manual Control
• Cannot be used with — Optional voltage MCV112 12 kg
regulators Shipped loose
• Technical — Allows generator output
RFI Suppression on KCR-760 1V/Hz —
voltage to be controlled manually by a
60 Hz 21 kg
potentiometer or automatically by a voltage
• Technical — Adds shielding to KCR-760 regulator. Has isolation feature for
voltage regulator to reduce RF interference. maintenance.
• Requires — 2400 or 2800 frame generator • Requires — 2400 or 2800 frame generator
• Cannot be used with — Optional voltage and digital voltage regulator
regulators • Cannot be used with — RFI suppression
RFI Suppression on KCR-760 2V/Hz —
50 Hz 21 kg
• Technical — Adds shielding to KCR-760
voltage regulator to reduce RF interference.
• Requires — 2400 or 2800 frame generator
• Cannot be used with — Optional voltage
regulators

35
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

OPTIONALATTACHMENTS
Other Options for High Voltage Generators, Cont.
Auto Manual Control Motor Operated Potentiometer —
MCV300 3 kg KCR 760 1V/Hz, 60 Hz 9 kg
Shipped loose Shipped loose
• Technical — Allows generator output voltage • Technical — Remote control of
to be controlled manually by a potentiometer potentiometer for AVR
or automatically by a voltage regulator. Does • Requires — 2400 or 2800 frame generator
not have isolation feature for maintenance. for 60 Hz applications only
• Requires — 2400 or 2800 frame generator • Cannot be used with — Optional voltage
• Cannot be used with — Digital voltage regulators or RFI suppression
regulator or RFI suppression Motor Operated Potentiometer
Auto Manual Control KCR 760 1V/Hz, 50 Hz 9 kg
MCV108 36 kg Shipped loose
Shipped loose • Technical — Remote control of
• Technical — Allows generator output voltage potentiometer for AVR
to be controlled manually by a potentiometer • Requires — 2400 or 2800 frame generator
or automatically by a voltage regulator. Has for 50 Hz applications only
isolation feature for maintenance. • Cannot be used with — Optional voltage
• Requires — 2400 or 2800 frame generator regulators or RFI suppression
• Cannot be used with — Digital voltage Motor Operated Potentiometer
regulator or RFI suppression KCR 760 2V/Hz, 60 Hz 9 kg
Diode Fault Detector 12 kg Shipped loose
Shipped loose • Technical — Remote control of
• Technical — Senses open or short diodes potentiometer for AVR
• Requires — 2400 or 2800 frame generator • Requires — 2400 or 2800 frame generator
and 2V/Hz KCR 760 for 60 Hz applications
• Cannot be used with — RFI suppression
only
• Cannot be used with — Optional voltage
regulators or RFI suppression

36
P R O D U C T I N F O R M AT I O N – S R 4 B H V G E N E R AT O R S

OPTIONALATTACHMENTS
Other Options for High Voltage Generators, Cont.
Motor Operated Potentiometer Inlet Air Filter — Generator 250 kg
KCR 760 2V/Hz, 50 Hz 9 kg • Technical — Has washable filter elements
Shipped loose and a differential air pressure switch
• Technical — Remote control of • Requires — 2800 frame generator
potentiometer for AVR
Conversion GP — LHSFEE
• Requires — 2400 or 2800 frame generator
• Technical — As seen from exciter end.
and 2V/Hz KCR 760 for 50 Hz applications
Replaces Standard RH side extension box
only
• Requires — 2400 or 2800 frame generator
• Cannot be used with — Optional voltage
regulators or RFI suppression Conversion GP — Top Cable Entry
Thermostat for Space Heater 3 kg • Technical — As seen from exciter end.
Replaces Standard RH side extension box
• Technical — For automatic control of space
heater. • Requires — 2400 or 2800 frame generator
• Requires — 2400 or 2800 frame generator Conversion GP
6 Load, 6 Terminal 100 kg
Inlet Air Filter — Generator 250 kg
• Technical — Three phase leads located on
• Technical — Has washable filter elements
the opposite side of the generator from three
and a differential air pressure switch
neutral leads
• Requires — 2400 frame generator
• Requires — 2400 or 2800 frame generator

37
LEKX9463 Materials and specifications are subject to change without notice. © 1999 Caterpillar Inc.
All rights reserved.