IEPL/STP/Rep-002 Hyderabad

21/08/2023
To
The Managing Director
Le Securise
Hyderabad

Sub.: STP Performance and evaluation Report.

Kind attn. Sri Divyesh ji,

Sir,
Greetings of the day. This is with reference to our telephonic discussions and site visit to
STP at BST Homes, Tukkuguda on 21st Aug. 2023. Our Technical Team of Engineers has
visited your site on 21st Aug 2023 and the following observations were made. These issues
need to be resolved for smooth and efficient operation of the STP.

EQUIPMENT BRAND/
SNO DETAILS MAKE MODEL OUTLET QTY STATUS REMARKS
INLET NOT
1 FLOW METER KHRONOS 1NO WORKING N/A
INCOMING
LINE IS NOT
CONNECTED
TO THE BAR
SCREEN
CHAMBER AND
IS DIRECTLY
DICHARGING
INTO THE
MS 600*600 NOT COLLECTION
2 BAR SCREEN mm AVAILABLE NA 3 Nos Not in use TANK
COLLECTION
TANK
CLEANING AND
AREATION TO
LEAKS ARE BE DONE TO
RAW WATER NO OBSERVED IN AVOID PUMP
TRANSFER INFORMATION NOT BOTH INLET BLOCKING
3 PUMPS (2W) AVIALABLE AVAILABLE 2 AND OUTLET ISSUE
1 BLOWER NOT
WORKING
FROM LONG
TWO BLOWER TIME . 2
WORKING (1 BLOWERS
AIR EVEREST NOT NEED
4 BLOWER(2W+1S) MAKE 305 M3/HR 3NOS WORKING ) ATTENTION IN
CHANGING OIL
AND GEAR OIL
2 MOTORS
RUNNING
(1MOTOR
BLOWER M5125-10 NOT
5 MOTORS(2W+1S) KIRLOSKAR HP 3NOS WORKING)
SLUDGE NOT
RECIRCULATION AVIALABLE AT
6 PUMP1 SITE
NEEDS TO BE
SERVICED FOR
BETTER
PERFORMANCE
AND TO AVOID
SOLIDS
SLUDGE NOT ENTERING
RECIRCULATION AVIALABLE AT FILTER FEED
7 PUMP2 SITE TANK
1 PUMP FOR
EACH SET LAOD ON THE
TOTAL IN 2 REMAINING
PUMPS PUMS AND
AVIALABLE 2 LEKAGES ON
FILTER FEED NOT NOT ARE NOT EXISTING
8 PUMPS 4 PROVIDED PROVIDED 4NOS AVAILABLE PUMPS
NOT IN
OPERATIONAL
TUSHAKO STAGE NOT
9 SCREW PUMP 1 PUMPS 1NOS USED
NOT IN
OPERATIONAL
TUSHAKO STAGE NOT
12 SCREW PUMP 2 MAKE 1390 RPM 1NO USED
PRESSURE SAND MEDIA
13 FILTER FRP 18’’65’’ 1NO WORKING REPLACED
ACTIVATED MEDIA
14 CARBON FILTER FRP 1 NO WORKING REPLACED
NOT CHLORINE
CHLORINE AVIALABLE IN PROCESSING
15 DOSING SYSTEM ENDOSE ENDOSE NA SITE NOT DONE
NOT NOT NOT
TREATED WATER AVIALABLE AT AVIALABLE AVIALABE AT
16 SUPPLY PUMP 1 SITE AT SITE SITE
NOT NOT NOT
TREATED WATER AVIALABLE AT AVIALABLE AVIALABE AT
17 SUPPLY PUMP 1 SITE AT SITE SITE
18 HNS SET 1 GRUNDFOS MG132SB2- 5.7 BAR NOT NEED TO OPEN
38FF265H3 WORKING AND CHECK
THE PUMP IF
CAN BE
SERVICED OR
REPLACED
MG132SB2-
19 HNS SET1 GRUNDFOS 38FF265H7 5.7 BAR WORKING
NOT USED NEED TO
BYPASS PUMP( FROM CHECK AND
20 sludge pump) KIRLOSKAR SP-2HM 3 HP STARTING START
FINE BUBBLE
AREATION DIFFUSER
21 SYSTEM TYPE

REMARKS AT SITE
THE BAR SCREEN INSTALLED IS ALREADY RUSTED AND NEEDS TO BE REPLACED
WITH A NEW BASKET TYPE BARSCREEN in SS TO PREVENT ESCAPE OF LARGE
OBJECTS LIKE CLOTHES, RAGS, PLASTIC POUCHES, BAGS, DIAPERS, SANITARY
PADS, CONDOMS ECT. AND PREVENT BLOCKQGE OF THE PUMPS IN THE
COLLECTION TANK AND PREVENT WINDING PROBLEMS IN MOTORS DUE TO
1. OVERLOADING.
BOTH THE SUCTION AND DELIVERY OF RAW SEWAGE WATER PUMPS ARE
LEAKING. THE SUCTION CHAMBER IS PITTED AND HOLES FORMED AT MANY
PLACES AND CORRODED. DUE TO THIS IT IS LEAKING AND THE PIPELINES NEED
2. TO BE RECTIFIED
OUT OF THE 3 BLOWERS ONLY 2 Nos ARE WORKING LEADING TO AN INCREASE IN
THE LOAD ON BLOWERS. GEAR OIL IS TO BE REPLACED PERIODICALLY WHICH IS
3. NOT BEING DONE AND WILL LEAD TO BLOWER DAMAGE
A CORE CUT IS MADE NEAR BLOWER 3 AND HAS NOT BEEN CLOSED. IT IS VERY
4. DANGEROUS FOR MANPOWER AND UNSAFE PRACTICE
SLUDGE RECIRCULATION PUMPS:1,2,3&4 ARE NOT AVIALABLE AT SITE AS PER
CURRENT VENDOR , MLSS RECIRCULATION IS NOT HAPPENING THEREBY
5. REDCUING THE TREATMENT EFFICIENCY.
MLSS QUANTITY IS TOO LOW, NEED TO DEVELOP WITH CULTURES AND
6. NUTRIENTS DOSING.
CHLORINE DOSING IS NOT DONE IN FILTER WATER WHICH WILL NOT KILL THE
PATHOGENIC BACTERIA AND LEADING TO SMELL AND COLOR DEVELOPMENT IN
7. FINAL TREATED WATER.
FILTER FEED PUMP SET 1 : ONLY ONE PUMP IS AVIALABLE AT SITE CAUSING
LOAD ON SECOND PUMP. THIS WILL REDUCE THE LIFE OF THE PUMP AND ALSO
8. CHANCES OF FAILURE OF THE PUMP ARE VERY HIGH.
FILTER FEED PUMP SET 2 : ONLY ONE PUMP IS AVIALABLE AT SITE CAUSING
9. LOAD ON SECOND PUMP.
BOTH INLET AND OUTLET WATER FLOW METERS ARE NOT WORKING WHICH IS
10. LIMITING THE RECORDING OF WASTE WATER GENERATED AND TREATED AT SITE
HYDRO PNEUMATIC SYSTEM 1 (HPS) IS NOT WORKING, HPS SYSTEM2 IS ONLY
11. WORKING
CONTROL PANELS: THE ELECTRICAL CONTROL PANELS IN THE SITE ARE NOT IN
GOOD CONDITION. THEY ARE LEFT OPEN AND LEAD TO ELECTROCUTION TO
12. OPERATORS, AS CABLES ARE ALSO NOT TUTRIONED
SCREW PUMPS: THEY ARE NOT IN OPERATION , THEY ARE TO BE OPERATED FOR
RECIRCULATION OF MLSS FAILING TO DO SO WILL HINDER SLUDGE THICKENING
AND ESCAPE OF SLUDGE BACK TO THE TREATED WATER AND DARK COLORED
13. WATER AT OUTLET
FILTER PRESS DRAIN LINE INSTALLATION IS NOT COMPLETED AND HAS TO BE
14. DONE IMMEDIATELY.

In conclusion, the STP electromechanical parts maintenance is in a bad state and needs to be
revamped and repairs need to be undertaken urgently.
A separate quote will be provided for the optimization and repairs of the damaged
equipment in the STP. We can facilitate the repairs of the equipment to the Owners
association and can get the repairs done and take up the O&M of the STP for higher
efficiency and provide good quality treated water for reuse and over to our company.

Thanking you Sir,


Yours Truly,

Dr. Renu Sarath Babu Vegesna