Download as pdf
Download as pdf
You are on page 1of 2
Prelim Paper TE (Civil) AY 2023-24 (Semester -1) Course Code: (301003) Design of Steel Structure (2019 PAT) Time: 2% Hours - Peal Sinhgad College of Engineering, Pune Department of Civil Engincering Max. Marks: 70 Anstructions to the candidates I) Neat diagrams must be drawn wherever necessary 2) Assume suitable data if necessary: QNo. . Question Marks | CO. BL | Ke | PI Q1) a) | State and explain in brief type of column base. co3 BL2] C Check the adequacy of ISHB 450@ S54 kg/m to canny a by _ | factored axial load of 730 km at an eccentricity of 270 mm about cos sis | ror » | major axis The effective length otcolumn ids. Covstdes ony : section streneth, oR ae &: 2) a) | Find buckling class of section ISHB 400@ 77.4 kgm used as a” ‘lca Bal c x column a " Ee A column consist of ISHB 350 @ 67.4 kg/m carries an axial ») compression factored load of 11600 KN. Design a suitable bolted gusseted base. The base is rest on M 20 grade of concréte pedestal, Use 20 mm diameter bolts for the connection Q3)a) | State and explain laterally restrained and ‘unrestrained beam with suitable sketch. ») A simply sopported beam of span 6 m Toaded with uniformly | distribute load 25 k:N/m including self weight. Italso subject to| two point load of 50 KN each at quarter span from supports. If the compression flange is laterally restrained, design the section using Isection, OR Qi) a) | Classify the section ISLB 500 @ 75.0 kgim and ISA 100 x75 8mm @ 10.5 ke/m used as a beam. » Asimply supported beam carries a uniformly distributed I of magnitude W kNim on entire span of 6 m, The compression flange is laterally unsupported throughout the span. Find the intensity of uniformly distributed load the section ISMB 500 @ 89.6 kg/m can carry for the beam safely. Both ends of beam are fully restrained against torsion a cos BL3 | FDP Qs) Determine panel point dead load, imposed Toad and wind load for a truss as shown in Figure 1. Assume design wind pressure 35 1100 Nim, use G-L Sheet and the centre to centre spacing of truss as 4 m. Assume self-weight of purlin 120 N/m a cos ‘Ktop/aa/Prelim Que. Paper%20 Std. Format - Doss 23-24.pdf OR Design a simply supported gantry girder to carry electric overhead travelling crane, given: Span of gantry girder = 6 m Span of crane girder = 15 m Crane capacity = 200 kN Self weight of trolley, hook, electric motor etc. = 40 KN Self weight of crane girder exclading trolley = 200 kN Minimum hook approach ~ 1.0 m Distance between wheels = 3 m Self weight of rails = 0.2 kN/m 7 BL Qi) a) | Explain in brief IS provisions for Tength and spacing of intermittent weld cos BL2 ») ‘A Simply supported welded plate girder of span 30m i subjected to uniformly distributed load 30 KN/m on whole span exclading self weight of plate girder. Design cross section of plate girder. Assume compression flange is laterally supported throughout the span. 4 cos OR QS) a) | Explain in brief flange curtailment of plate girder. cos » ‘Asimply supported welded plate girders designed for the span of 24 m. It is subjected to a shear force of 2300 KN and bending moment of 20700 kNm. A section used for plate girder to carry above load is as given below - Flanges - 780 mm wide and 50 mm thick ‘Web - 16 mm thick and 2600 mm deep Design intermittent welded connection between flange and web. Also design end bearing stiffener. i“ C06 BL iB © 2 Search Summary of CO and BL marks distribution co COI] COD | COB | COF] COS |.COs % Maris Allotted Bloom: Taxonomy Levels | BLI [BL2 | BLS | BL4] BLS | BL6 % Marks Allotied yreviations: © CO-Course outcome: = PO-Programme Outcomes BL - Blooms Taxonomy Levels (BLI-Remember, BL2-Understand, BL3-Apply, BL4-Analyse, BLS-Evalute BL6- Create) Criteria & Specifications, Practical Constraints, Design instrumentalites = PI- Performance Indicator. KC - Knowledge categories - Factual, Conceptual, Procedural, Metacognitive, Fundamental Dezign Principles, LEoO@e8 BE

You might also like