Polyrad ® XT Wire and Cable

Locomotive and Rapid Transit Wire, Single Conductor 110°C/125°C

600 Volt Chart


SINGLE CONDUCTOR
CATALOG CONDUCTOR TYPE OF APPROX. NOMINAL NOMINAL NOMINAL NET CABLE AMPACITY
NUMBER (AWG/kcmil) STRANDING AREA CONDUCTOR INSULATION CABLE CABLE (FREE AIR 40˚C
125˚C SIZE AND (kcmil) DIAMETER THICKNESS DIAMETER WEIGHT AMBIENT)
STRANDING lbs/ kg/
Inches mm Mils mm Inches mm 110˚C 125˚C
1000 ft. km

280710 18 19/30 CONC 1900 0.048 1.22 30 0.76 0.110 2.79 12 18 30 32


280720 16 19/29 CONC 2601 0.054 1.37 30 0.76 0.116 2.95 14 21 35 38
280700 14 19/27 CONC 3831 0.071 1.80 30 0.76 0.133 3.38 20 30 41 44
296420 12 19/25 CONC 6088 0.090 2.29 30 0.76 0.152 3.86 29 43 52 56
303910 10 27/24 BUNCH 10910 0.120 3.05 30 0.76 0.182 4.62 45 67 73 79

296490 8 37/24 CONC 14950 0.140 3.56 45 1.14 0.232 5.89 68 101 85 92
330230 6 61/24 CONC 24640 0.181 4.60 45 1.14 0.273 6.93 105 156 120 130
355320 5 91/24 ROPE 36760 0.242 6.15 45 1.14 0.334 8.48 145 216 160 173
318420 4 105/24 ROPE 42420 0.263 6.68 45 1.14 0.354 8.99 165 246 168 181
355330 3 125/24 ROPE 50500 0.285 7.24 45 1.14 0.377 9.58 194 289 199 215

355340 2 150/24 ROPE 60600 0.307 7.80 45 1.14 0.399 10.13 224 333 214 231
355350 1 225/24 ROPE 90900 0.380 9.65 55 1.40 0.494 12.55 351 522 268 289
355360 1/0 275/24 ROPE 111100 0.437 11.10 55 1.40 0.551 14.00 422 628 304 328
355370 2/0 325/24 ROPE 131300 0.458 11.63 55 1.40 0.572 14.53 475 707 338 364
355380 3/0 450/24 ROPE 181800 0.549 13.94 55 1.40 0.663 16.84 657 978 414 446

355390 4/0 550/24 ROPE 222200 0.611 15.52 55 1.40 0.725 18.42 798 1188 472 509
355400 262 650/24 ROPE 262600 0.652 16.56 65 1.65 0.786 19.96 956 1423 524 565
355410 313 775/24 ROPE 313100 0.720 18.29 65 1.65 0.854 21.69 1141 1698 590 636
355420 373 925/24 ROPE 373700 0.795 20.19 65 1.65 0.929 23.60 1325 1972 657 708
355430 444 1100/24 ROPE 444400 0.855 21.72 65 1.65 0.989 25.12 1604 2387 734 791

355440 535 1325/24 ROPE 535300 0.925 23.50 80 2.03 1.091 27.71 1991 2963 828 893
355450 646 1600/24 ROPE 646400 1.035 26.29 80 2.03 1.201 30.51 2281 3395 931 1004
355460 777 1925/24 ROPE 777700 1.120 28.45 80 2.03 1.286 32.66 2747 4088 1047 1129
355470 929 2300/24 ROPE 929200 1.230 31.24 80 2.03 1.396 35.46 3410 5075 1168 1259
355480 1111 2750/24 ROPE 1111000 1.328 33.73 95 2.41 1.524 38.71 3924 5840 1254 1352

NOTE #1:
At the option of the purchaser, the manufacturer’s standard type of stranding will be acceptable providing that
the conductor diameter does not exceed the values shown. The total number of wires shall be as specified,
plus or minus one percent, except 150/24 which may vary by minus two percent, providing that the conductor
diameter does not exceed the values shown.
NOTE #2: 3
These items meet all dimensional and performance requirements for 110˚C applications.
Polyrad ® XT Wire and Cable
Locomotive and Rapid Transit Wire, Single Conductor 110°C/125°C

2000 Volt Chart


SINGLE CONDUCTOR
CATALOG CONDUCTOR TYPE OF APPROX. NOMINAL NOMINAL NOMINAL NET CABLE AMPACITY
NUMBER (AWG/kcmil) STRANDING AREA CONDUCTOR INSULATION CABLE CABLE (FREE AIR 40˚C
125˚C SIZE AND (kcmil) DIAMETER THICKNESS DIAMETER WEIGHT AMBIENT)
STRANDING
Inches mmInchesMils
mm Mils
mm mm Inchesmm mm lbs/lbs/ kg/kg/
Inches 110˚C
110˚C 125˚C
10001000
ft. ft. kmkm

300620 18 19/30 CONC 1900 0.048 1.22 45 1.14 0.140 3.56 17 25 30 32


300890 16 19/29 CONC 2601 0.054 1.37 45 1.14 0.146 3.71 19 28 35 38
280740 14 19/27 CONC 3831 0.071 1.80 45 1.14 0.163 4.14 25 37 41 44
303480 12 19/25 CONC 6088 0.090 2.29 45 1.14 0.182 4.62 34 51 52 56
301260 10 27/24 BUNCH 10910 0.120 3.05 45 1.14 0.212 5.38 52 77 73 79

269970 8 37/24 CONC 14950 0.140 3.56 55 1.40 0.254 6.45 76 113 85 92
297970 6 61/24 CONC 24640 0.181 4.60 55 1.40 0.295 7.49 113 168 120 130
355490 5 91/24 ROPE 36760 0.242 6.15 55 1.40 0.356 9.04 153 228 160 173
301270 4 105/24 ROPE 42420 0.262 6.65 55 1.40 0.376 9.55 174 259 168 181
325290 3 125/24 ROPE 50500 0.285 7.24 55 1.40 0.399 10.13 204 304 199 215

302440 2 150/24 ROPE 60600 0.307 7.80 55 1.40 0.421 10.69 235 350 214 231
355500 1 225/24 ROPE 90900 0.380 9.65 65 1.65 0.514 13.06 363 540 268 289
296500 1/0 275/24 ROPE 111100 0.437 11.10 65 1.65 0.571 14.50 435 647 304 328
301280 2/0 325/24 ROPE 131300 0.458 11.63 65 1.65 0.592 15.04 489 728 338 364
300900 3/0 450/24 ROPE 181800 0.549 13.94 65 1.65 0.683 17.35 673 1002 414 446

296510 4/0 550/24 ROPE 222200 0.611 15.52 65 1.65 0.745 18.92 815 1213 472 509
355510 4/0 550/24 ROPE 222200 0.611 15.52 105 2.67 0.825 20.96 891 1326 472 509
267040 262 650/24 ROPE 262600 0.652 16.56 75 1.91 0.808 20.52 975 1451 524 565
355520 262 650/24 ROPE 262600 0.652 16.56 105 2.67 0.866 22.00 1040 1548 524 565
296520 313 775/24 ROPE 313100 0.720 18.29 75 1.91 0.876 22.25 1164 1732 590 636

355530 313 775/24 ROPE 313100 0.720 18.29 105 2.67 0.934 23.72 1233 1835 590 636
304020 373 925/24 ROPE 373700 0.795 20.19 75 1.91 0.951 24.16 1349 2008 657 708
355540 373 925/24 ROPE 373700 0.795 20.19 105 2.67 1.009 25.63 1422 2116 657 708
300180 444 1100/24 ROPE 444400 0.855 21.72 75 1.91 1.011 25.68 1630 2426 734 791
355550 444 1100/24 ROPE 444400 0.855 21.72 105 2.67 1.069 27.15 1709 2543 734 791

263400 535 1325/24 ROPE 535300 0.925 23.50 90 2.29 1.115 28.32 2018 3003 828 893
355560 535 1325/24 ROPE 535300 0.925 23.50 120 3.05 1.175 29.85 2101 3127 828 893
355570 646 1600/24 ROPE 646400 1.035 26.29 90 2.29 1.225 31.12 2311 3439 931 1004
355580 646 1600/24 ROPE 646400 1.035 26.29 120 3.05 1.285 32.64 2400 3572 931 1004
260080 777 1925/24 ROPE 777700 1.120 28.45 90 2.29 1.310 33.27 2777 4133 1047 1129

355590 777 1925/24 ROPE 777700 1.120 28.45 120 3.05 1.370 34.80 2870 4271 1047 1129
355600 929 2300/24 ROPE 929200 1.230 31.24 90 2.29 1.420 36.07 3443 5124 1168 1259
355610 929 2300/24 ROPE 929200 1.230 31.24 120 3.05 1.480 37.59 3545 5276 1168 1259
355620 1111 2750/24 ROPE 1111000 1.328 33.73 110 2.79 1.558 39.57 3980 5923 1254 1352
355630 1111 2750/24 ROPE 1111000 1.328 33.73 120 3.05 1.578 40.08 4017 5978 1254 1352

NOTE #1:
Where additional insulation thickness is desired for added mechanical protection, these values
should be considered.

NOTE #2:
At the option of the purchaser, the manufacturer’s standard type of stranding will be acceptable providing that the
conductor diameter does not exceed the values shown. The total number of wires shall be as specified, plus or minus
one percent, except 150/24 which may vary by minus two percent, providing that the conductor diameter does not
exceed the values shown.

NOTE #3:
4 These items meet all dimensional and performance requirements for 110˚C applications.