ABB Utilities GmbH RTU560

Remote Terminal Unit


Data Sheet
Analog Input 23AE21

Application
The 23AE21 board records up to eight analog mea- low-pass filter suppresses non line frequency ac dis-
sured values. The 23AE21 board allows it to connect turbance.
all typical measured value ranges
The AD-converter, operating with the sigma-delta
It can be configured for the following measurand method scans with a higher resolution and has addi-
ranges by simple switches and jumpers: tional algorithms for a high suppression of line fre-
V  2 mA quency and line harmonics interference voltages.
Even for a deviation of =10 % of the line frequency
V  5 mA
there is still given a suppression of > 45 dB. The in-
V  10 mA ternal high resolution allows it to scan all measuring
V  20 mA ranges (exception: 2 V DC (11 bit +sign)) with the
V  40 mA same resolution (12 bit + sign) on one board. A
9th channel is used for automatic zero calibration.
V  2 V DC
V 0 ... + 20 V DC

Other effective ranges and live ziro signals become AD- -converter
generated out of these ranges through conversion of Multiplexer Connection
the communication unit CMU.
+
EA11
Protection circuit

The 23AE21 is functional- and pin-compatible to the


Resistor network

D
23AE20 board.
B
U
Characteristics S --
EA10
Basic checks and computing intensive, cyclical pro- M Input circuit
cessing functions will already be done on the board
O
and remove therefore the burden from the central
unit. Relevant changes transmits the board as event D +
U A EA81
via the peripheral bus. Input circuit --
L EA80
The 8 differential inputs are not potentially isolated E
against the RTU560 power supply.

Unipolar or bipolar values resolves the 23AE21 into


4096 steps (12 bit plus sign) for 100 % of the measur-
ing signal.
Fig. 1: Block diagram
The differential inputs are protected against static
Analog input board 23AE21
and dynamic over-voltages by a protection circuit. A

Doc.- -No.: 1KGT 150 402 V001 1 1


ABB Utilities GmbH

Data Sheet Analog Input 23AE21 RTU560

The analog input board 23AE20 can carry out the fol- The microcontroller controls the A/D converter and
lowing processing functions on the measured val- executes all of the processing functions of the con-
ues: figured measured values within the conversion time.
V Zero point monitoring Furthermore the microcontroller is responsible for in-
V Switch- -over recognition teractive communication with the RTU560 system
V Smoothing bus. All configuration characteristics and proces-
sing parameters are downloaded from the CMU via
V Threshold value monitoring on absolute
the RTU system bus.
value or with accumulation and periodic
background transmission. During initialization and operation the board carries
V Limit value monitoring with event recording out a number of tests. If a fault occurs it is reported to
Measuring range and line frequency are easily to the CMU. All fault conditions impairing the function of
configure by switch registers respectively jumpers. the board are displayed as common fault signal with
The microcontroller needs these configurations pa- a light emitting diode (ST) on the front panel. A failure
rameters to setup the AD-converter. of the board is detected by the CMU.

Conversion period Scan cycle


Line frequency
per channel per board
[Hz]
[ms] [ms]

60 62.5 500
50 72.5 580
16.6 202.5 1620

2 Doc.- -No.: 1KGT 150 402 V001 1


ABB Utilities GmbH
RTU560 Data Sheet Analog Input 23AE21

Technical Data
In addition to the RTU560 general technical data, the following applies:
Input channels Power Supply
Inputs: 8; differential inputs Supply: 5V / max. 230 mA
Measuring ranges:  2 mA
 5 mA Mechanical Layout
 10 mA
 20 mA Printed circuit 3HE, Euro- -card format
 40 mA board: (160 x 100 mm)
 2 V DC / 0...+20 V DC Front panel: 4R, 1 slot (20 mm)
Weight: approx. 0.3 kg
Shunt / impedance 50 Ω at 40 and 20 mA
150 Ω at 10 to 2 mA
110 kΩ at 2 V and 20 V DC Connection Type
Continuous load max. 80 mA Connector: indirect, 48 pole
without destruction: for range 40 and 20 mA Type F DIN 41612
max. 40 mA
for range 10/5 to 2 mA
max. 38 V resp. Test Voltages
max. 0.5 mA Insulation voltage 2.5 kV AC
for range 2 and 20 V DC withstand test: IEC 60870-2-1 (VW 3)
Resolution: 12 bit + sign =  100% Impulse voltage 4 kV (1,2/50)
all ranges except  2 V DC withstand test: IEC 60664-1
11 bit + sign for  2 V DC Overvoltage Category III

Common mode voltage: Function limit


typ.  8 V DC
Electromagnetic Compatibility
Absolute maximum rating Electrical fast 1 kV
 150 V DC transient test: IEC 801- -4 (class 3)
Common mode rejection
at 0 ... 50 Hz High frequency 2.5 kV (1MHz)
> 70 dB at +25 _C disturbance test: IEC 255- -4 (class III)
> 60 dB at 0 ... +25 _C
Environmental Conditions
Line frequency > 100 dB for fN  2%
interference suppression: > 45 dB for fN  10% Temperature: 0 ... 70 _C
Line frequency (fN): 16.6, 50 or 60 Hz Relative humidity: 5 ... 95 %
(non condensing)
Error on delivery: ± 0.1 %
± 0.2 % for  2 V DC Ordering Information
Linearity error: ± 0.1 % Front plate plastic: light beige
Temperature drift: ± 100 ppm/K (0...70˚C) 23AE21R5011 1KGT004700R5011

Doc.- -No.: 1KGT 150 402 V001 1 3


ABB Utilities GmbH

Data Sheet Analog Input 23AE21 RTU560

ABB Utilities GmbH


Kallstadter Straße 1
68309 Mannheim (Germany)
Telephone +49 (0) 621 381-7592
Telefax +49 (0) 621 381-7622 03/2002 Subject to alteration

4 Doc.- -No.: 1KGT 150 402 V001 1