8 Stowage of liferafts Proper fitting of weak link (in case of a type without Satisfactory
weak link, notice to be posted)
No Life Saving Appliances (LSA) Shipboard Inspection (Crew) Periodic Inspection & Service Frequency Tick Satisfied/Not
Condition of embarkation ladder 30-Jul-15
9 Distress Flares At least 12 parachute rocket signals available on board. Validity:
Rocket Parachute Flares: May 2018 Satisfactory
Smoke Signals: May 2018 & May 2016
10 Line Throwing Appliances Four rockets capable of carrying line at least 230m. Line Throwing Rocket: NOV 2017 Satisfactory
Proper instruction available.
11 Immersion suits Condition of Immersion suits. Air pressure test (Every 3 year)
Provided for every person and as additional. When tested:21.09.2010
12 Thermal Protective Aids For persons on board not provided with 30-Jul-15 Satisfactory
immersion suits, and ready for immediate use.
13 Two-way VHF radio-telephone At least three sets complying with the standards. 30-Jul-15 Satisfactory
apparatus Operation of the apparatus.
14 Radar transponders (SART) At least one radar transponder on each side of wheelhouse. Validity of battery: September 2017
In case of free-fall lifeboat, one is stowed in a free-fall 30-Jul-15 Satisfactory
lifeboat and the other one is fitted in the wheelhouse. 30-Jul-15
15 Lifejackets A lifejacket for every person on board with
retro-reflective tapes.
Additional lifejackets for persons on watch and for use 30-Jul-15 Satisfactory
at survival craft stations.
Each lifejacket with a whistle & light.
16 Lifebuoys for new ships constructed Proper no. of lifebuoys with marking and retro-reflective tapes Lifebuoy Lights(Electric Type) -
on or after 1 July 1986 (83 Amend.) MOB - Two buoys with self-igniting lights (SIL) and smoke Battery replacement: maker's expiry date or yearly.
L(m) No. of buoys signals being capable of released by release gear, having a When replaced: 25 July 2014
less than 100m 8 mass of at least 4kg on bridge wings. Validity of MOB buoy smoke signals:
less than 150m 10 Illumination of SILs. Maker's expiry date: MAY 2018 & MAR 2017
less than 200m 12 Operation of release gear. Satisfactory
marOff Deck Manual Issued 1 Aug 2012
Page 4 of 10 Form PMS-D-05 Rev. 3.0
200m and over 14 At least half of the total number of buoys to be provided
with SILs. 30-Jul-15
Illumination of SILs.
No Life Saving Appliances (LSA) Shipboard Inspection (Crew) Periodic Inspection & Service Frequency Tick Satisfied/Not
At least one buoy with a buoyant line on each side.
(30m or twice the height at stowage position above water
level, whichever is the greater.) 30-Jul-15 Satisfactory
The remaining buoys without attachment on
both sides.
17 On-board Operation of two-way communications between
communications emergency control station, muster and 30-Jul-15 Satisfactory
embarkation stations and strategic positions.
18 Public address system Operation of the system on weekly basis. Every Saturday
19 Medical Oxygen Medical Oxygen Cylinders
Hydraulic Pressure Test (5 Yearly) Satisfactory
When tested: 31 May 2015
marOff Deck Manual Issued 1 Aug 2012
Page 5 of 10 Form PMS-D-05 Rev. 3.0
No Fire Fighting Appliances (FFA) Shipboard Inspection (Crew) Periodic Inspection & Service Frequency Tick Satisfied/Not
1 Fire doors Operate satisfactorily. 30-Jul-15
Self-closing doors not to be fitted with hold-back hooks.
2 Skylights Closing arrangements in good order. 30-Jul-15
Skylights to be of steel and not contain glass panels.
3 Fire dampers Operate satisfactorily:
Cargo holds Satisfactory
Engine room
Accommodation spaces 30-Jul-15
Control stations
Other spaces
Clear marking of “Close-Open”.
No hole / defection of dampers
4 ®Main fire pumps Operate satisfactorily.
Proper pressure maintained. 30-Jul-15 Satisfactory
Pressure gauges in good order
5 Emergency fire pump Operates satisfactorily.
Proper pressure maintained.
Pressure gauges in good order. 30-Jul-15 Satisfactory
Prime mover in good condition.
Exhaust gas piping in good order.
6 Fire main piping No leakage, heavy wastage in lines.
No doublers, clamps, soft patches in lines. 30-Jul-15 Satisfactory
7 Isolation valves Operate satisfactorily. 30-Jul-15 Satisfactory
8 Hydrants Fire hoses easily coupled to hydrants
marOff Deck Manual Issued 1 Aug 2012
Page 6 of 10 Form PMS-D-05 Rev. 3.0
No Fire Fighting Appliances (FFA) Shipboard Inspection (Crew) Periodic Inspection & Service Frequency Tick Satisfied/Not
15 Foam type fire extinguishers Visual condition in good order.
of 45 litters capacity or Easily usable condition.
equivalent in engine room. Validity of the medium N.A N.A
Foam : one year
dry powder : five years
CO2 : measure at Class SS and IS
16 Fixed fire extinguishing Piping in lines in good order, without leakage Regular checking of lines by air blow at Class
arrangement in E/R, cargo spaces, or no heavy corrosion. SS and IS (Yearly for Malaysia flag)
and cargo pump room * Testing the audible alarm for the release of gas CO2 or Halon cylinders to be level/weight
(CO2 or Halon, foam, water spray) (CO2 or Halon) measured at Class SS and IS. Proper test
certificate on board. (Yearly for Malaysia flag)
When tested: 31 May 2015
Fixed CO2 Cylinders - Hydrostatic Pressure Test
And Internal Inspection. (10 Yearly, at least 10%)
When tested: 19 .09.2008
Fixed CO2 Hose Assemblies Made Of Synthetic
Rubber To Be Replaced (10 Yearly) Satisfactory
When replaced: 19 July 2012
Validity of foam liquid (5 years):
After 3 years, effectiveness of foam liquid to
be checked, and a sample test certificate
available on board. Yearly thereafter.
marOff Deck Manual Issued 1 Aug 2012
Page 8 of 10 Form PMS-D-05 Rev. 3.0
No Fire Fighting Appliances (FFA) Shipboard Inspection (Crew) Periodic Inspection & Service Frequency Tick Satisfied/Not
24 International shore connection. At least one (1) shore connection with standard flange
dimensions available on board.
Four sets of bolts and nuts, each of 16 ㎜ in 30-Jul-15 Satisfactory
diameter, 50 ㎜ in length available on board.
One gasket packing available on board.
25 Emergency lights Satisfactory lighting condition in engine room,
accommodation spaces, wheel house, 30-Jul-15 Satisfactory
Emergency lights control stations, outside passage.
Bulbs and glasses without damage.
26 Means of escapes Ready for immediate use.
Steps and handrails without damage. 30-Jul-15 Satisfactory
Lighting operates satisfactorily.
27 Emergency Escape Stowage condition in good order according to SCBA Cylinders -
Breathing Devices the fire control plan. Easily usable condition. Hydrostatic Testing (Frequency as per
(EEBD) Suitable maintenance according to the manufacturer's instructions) Satisfactory
manufacturer’s instruction. When test: 31 May 2015 & Feb 2015
Confirmation of air pressure.
28 Fixed Local Application Piping, pump, valves and nozzles in good order,
Fire-fighting System without leakage, heavy corrosion or damage.
Regular checking of lines by air blow or water 30-Jul-15 Satisfactory