The Elektronikon® unit controller is specially design~d to maximize the performance of your compressors
and air treatment equipment under a variety of conditions. Our solutions provide you with key benefits such
as increased energy efficiency, lower energy consumption, reduced maintenance times and less stress ...
less stress for both you and your entire air system.
• Clear icons and intuitive navigation provides you fast • Built in remote control and notifications functions
access to all of the important settings and data. provided as standard, including simple to use
Ethernet based communication.
• Monitoring of the equipment running conditions and
maintenance status; bringing this information to • Support for 31 different languages, including character
your attention when needed. • شاشة ملونة عالية الدقة تمنحك سهولة في الفهم based languages. تشغيل املعدات للتسليم على وجه التحديد •
.قراءة لظروف تشغيل الجهاز .وموثوق به الحتياجاتك من الهواء املضغوط
• الرموز الواضحة والتنقل السهل يوفر لك سري ًعا
.الوصول إلى كافة اإلعدادات والبيانات املهمة • املدمج في وظائف التحكم عن بعد واإلخطارات
• مراقبة ظروف تشغيل املعدات و
بما في ذلك سهولة االستخدام، يتم توفيره كمعيار
حالة الصيانة إحضار هذه املعلومات إلى
.انتباهك عند الحاجة .االتصاالت القائمة على إيثرنت
بما في ذلك الشخصية، لغة مختلفة31 • دعم
.اللغات القائمة
سهل التنصيب
.• اإلطار املحتوي على الزيت كمعيار
0 . بدون تكاليف خفية، • حزمة الكل في واحد
Easy to install .• إمكانيات مجاري مرنة
• Oil-containing frame as standard.
• All-in-one package, no hidden costs.
• Flexible ducting possibilities.
0
Superior air intake filter
• Protects the compressor components by removing
99.9% of dirt particles> 3 µm.
• Reduces the dust load in the fine filter, doubling the
filter element lifetime wit hout reducing filter efficiency.
~ .واستهالك الطاقة
-4-niift
TECHNICAL SPECIFICATIONS
GA 16CJ+-315 (VSD) (50 Hz)
Working prt'~sure Capachy FAD (1) Installed Weight
Noise
motor
Stondord level (2)
Full Feoturc IJI Stonderd / Full Fcoture power Standerd Full Feature
GA200VSD-
13715
8.5 bar
GA 200VSD-
' 0783
10 bar
+
GA 200 VSD- 107113
14 bar
GA250VSD- 13891
8.5 bar
GA 250VSD - 12950
10 bar
GA 315VSD - 13192
10 bar
(I) Unit performance measured according to ISO 1217, Annex C and E. Edition 4 (2009).
I
Reference conditions: :الشروط املرجعية
- Absolute inlet preuure I bar /14.5 psi). .( بوصة مربعة/ رطل14.5 / ضغط املدخل املطلق داخل بار-
- lntako air temperature 2o•c /68"F}.
.{2o • c / 68 "F درجة حرارة هواء املدخل-
DIMENSIONS (2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 µPa)
dB (with uncertainty 3 dB/. Values determined according to noise level test code
ISO 2151 and noise measurement standard ISO 9614. Pressure dew point of
integrated refrigerant dryer at reference co nditions: 2•c to 3"C (36°F to 37°F).
3A 160'-315 W - FF (MV)
3A 200-315 VSD A 7.5 bar version et
3A 2oo-315 VSD A - FF 8.5 bar version at Bbar
3A20o-315VSDW 1Obar version at 9.5 bar
3A 200-315VSDW - FF 14 bar version at 12.5 bar
Lp WSA (re 20 µPa) ، في محطة العملA ( مستوى ضغط صوت االنبعاث املوزون2)
dB ( تم تحديد القيم وف ًقا لكود اختبار مستوى الضوضاء./ ديسيبل3 مع عدم اليقني
ISO 2151 ومعيار قياس الضوضاءISO 9614. نقطة ندى الضغط
درجة36) بوصة مئوية3 • درجة مئوية إلى2 :مجفف املبرد املدمج في الظروف املرجعية
.( درجة فهرنهايت37 فهرنهايت إلى
FLOWCHARTS
Fixed speed: GA• & GA
·,) "Ji
09 ,) \ ~ .
)J>)~) ~ 8 •
~ _.
V./
.,
\ '.
D •
C
lntakea,r
Oil
---
Air/ odm'xrure
Wet CO!!]E!~SBJtEif_
8 ·.J ·_ .1 I
I
E • CondensRte t
I
F Drred compressed a,r I
-......,~ • I
'tI!)I :
------------------------'
A • lncakea,r
C.
B • Air/oil mixture
01/
. . *!
D • Wet compressed air
♦ • ],
E • Condensate 1 ·7
I 1
I
F Or,ed compressed air
'-__,I .
.... t t ' \.
♦
.;arf-
'tt!±tt!:l±l:t±t-i- -
________________________
1}111 ,:
tj>
lnstniction book
2 -4
Flow diagram
----.
Regulating system
- - ---
11!------(D
A
u.c-..xx ,0,.-y,(1 I
[)
"°~ '
·~~ ••
I
I
~~~/;
l I
B:
I
~
,, -
APF196927 19
Instruction book ·
'
Reference Designation
A Elektronikon regulator
B Unloader
C To air cooler
D Air receiver/ Oil separator نظام التنظيم
E To I From oil cooler .Elektroni.kon® (A) يتم التحكم في الضاغط بواسطة منظم
يحافظ املنظم على صافي الضغط ضمن حدود الضغط القابلة للبرمجة عن طريق
التحميل و
Regulating system كما أنه يحمي الضاغط والشاشات.تفريغ الضاغط حسب استهالك الهواء
The compressor is controlled by the Elektroni.kon® regulator (A). .املكونات الخاضعة للخدمة
The regulator keeps the net pressure within programmable pressure limits by automatically loading and
unloading the compressor depending on the air consumption. It also protects the compressor and monitors
components subject to service. التفريغ
/ عندما. يزداد الضغط الصافي، إذا كان استهالك الهواء أقل من توصيل الهواء للضاغط
Unloading التسلسل التالي، (يصل الضغط الصافي إلى الحد األعلى لضغط العمل )ضغط التفريغ
increases. When the يحدث
If the air consumption is less than the air delivery of the compressor, the net pressure
/ سوف
net pressure reaches the upper limit of the working pressure (unloading pressure), the following sequence
will occur.
Step Description
1 The load / unload control valve (1) opens and connects air receiver (D) and unloader
pressure chamber (2).
The blow-off valve (5) opens and releases air from the air receiver (0). Both the air
receiver pressure and the unloader chamber (4) pressure drop.
2 Driven by the pressure difference in unloader pressure chambers (2) and (4), unloader
plunger (3) moves downwards. This downward movement forces the unloader disc (6)
to close the compressor stage inlet.
3 The compressor stage keeps drawing in air through calibrated bypass holes in the
unloader disc (6) to maintain the unloading pressure level.
4 The air delivery stops, the air receiver (D) pressure reaches its stable unload pressure
level and air is being recirculated in the compressor.
The unload pressure level is necessary to guarantee the oil injection on a few critical
points (bearings, rotors, ... ).
تحميل
فإن، (عندما ينخفض الضغط الصافي إلى الحد األدنى لضغط العمل )ضغط التحميل
Loading - التسلسل التالي ؛؛
'
When the net pressure decreases to the lower limit of the working pressure (loading pressure), the
following sequenc; ;ill occur. - - --- - --
( ومفرغ الحمولةD) ( ويربط مستقبل الهواء1) التفريغ/ يفتح صمام التحكم في الحمل1
.(2) غرفة الضغط
كال الهواء.(0) ( ويطلق الهواء من مستقبل الهواء5) يفتح صمام النفخ
.( هبوط الضغط4) ضغط املستقبل وغرفة التفريغ
مفرغ، (4) ( و2) مدفو ًعا بفرق الضغط في غرف ضغط املفرغ2
(6) هذه الحركة الهبوطية تدفع قرص التفريغ.( يتحرك لألسفل3) املكبس
.إلغالق مدخل مرحلة الضاغط
تستمر مرحلة الضاغط في سحب الهواء من خالل فتحات االلتفاف املعايرة في3
.( للحفاظ على مستوى ضغط التفريغ6) قرص التفريغ
( إلى ضغط التفريغ املستقرD) ويصل ضغط مستقبل الهواء، يتوقف توصيل الهواء4
.يتم إعادة تدوير املستوى والهواء في الضاغط
يعد مستوى ضغط التفريغ ضروريًا لضمان حقن الزيت في عدد قليل من الحاالت الحرجة
.(... ، الدوارات، النقاط )املحامل
20 APF196927
Next page
Instruction book .RJ/,(U(bp«J
Step Description
1 The blow-off valve (6) closes, resulting in a slow pressure rise In the air receiver (D).
This slow pressure rise Is caused by a small air flow drawn In through calibrated bypass
holes in the unloader disc (6).
2 The pressure in the unloader pressure chamber (4) equals the pressure rise in the air
receiver (D).
3 Once the pressure in air receiver (D) has reached a preset value, the load I unload valve
(1) closes. This results In a gradual pressure decrease in unloader pressure chamber
(2) towards the compressor stage inlet pressure level.
4 The pressure difference in unloader pressure chambers (2) and (4) causes the unloader
plunger (3) to move upwards. This upward movement forces unloader disc (6) to open
the compressor stage Inlet.
5 Air compression and air delivery resume.
Modulating control
The modulation control is available as an option. تعديل التحكم
Function
التحكم في التعديل متاح كخيار
I
To boost the compressor performance an adaptation of the standard unloader is made. The modulating
control valve can reduce the FAD (Free Air Delivery) down to 30% of the nominal FAD while maintaining
a pressure band of0.5 bar (7.3 psi). Besides FAD reduction, the consumed power also drops with
approximately 73% of the nominal power. When reducing the FAD, the SER (Specific Energy
Requirement) will increase up to 260% of nominal SER. Compared to machines which do NOT have a
Modulating Control Unloading Valve, maximum FAD will be 4% less and SER will be increased by 4%.
وظيفة
System setup
التحوير. يتم تعديل وحدة التفريغ القياسية، لتعزيز أداء الضاغط
االسمي مع الحفاظ عليهFAD من٪30 )توصيل الهواء املجاني( إلىFAD يمكن لصمام التحكم أن يقلل من
ً تنخفض الطاقة املستهلكة، FAD إلى جانب تقليل.( بوصة مربعة/ رطل7.3) بار0.5 شريط ضغط
أيضا
)طاقة محددةSER فإن، FAD عند تقليل. من القوة االسمية٪73 حوالي
مقارنة باآلالت التي ال تحتوي على ملف. االسميSER من٪260 املتطلبات( ستزيد حتى
.٪ 4 بنسبةSER وسيتم زيادة٪ 4 أقل بنسبةFAD سيكون الحد األقصى من، تعديل صمام تفريغ التحكم
وصف الخطوة
.(D) مما يؤدي إلى ارتفاع بطيء في الضغط في مستقبل الهواء، (6) ينغلق صمام التفريغ1
هذا االرتفاع البطيء في الضغط ناتج عن تدفق هواء صغير يتم سحبه من خالل ممر جانبي معاير
.(6) ثقوب في قرص التفريغ
( يساوي ارتفاع الضغط في الهواء4) الضغط في غرفة ضغط املفرغ2
.(املتلقي )د
أفرغ الصمام من الحمل، ( إلى قيمة محددة مسب ًقاD) بمجرد أن يصل الضغط في مستقبل الهواء3
ينتج عن هذا انخفاض تدريجي في الضغط في غرفة ضغط املفرغ.( يغلق1)
.( نحو مستوى ضغط مدخل مرحلة الضاغط2)
( إلى وجود وحدة التفريغ4) ( و2) يؤدي اختالف الضغط في غرف ضغط التفريغ4
(6) تجبر هذه الحركة الصعودية على فتح قرص التفريغ.( للتحرك ألعلى3) املكبس
.مدخل مرحلة الضاغط
. استئناف ضغط الهواء وتسليم الهواء5
APF196927 21
Step
/
Description
1 The blow-off valve (6) closes, resulting in a slow pressure rise in the air receiver (D).
This slow pressure rise ls caused by a small air flow drawn in through calibrated bypass
holes in the unloader disc (6).
2 The pressure in the unloader pressure chamber (4) equals the pressure rise in the air
receiver (D).
3 Once the pressure in air receiver (D} has reached a preset value, the load / unload valve
(1) closes. This results In a gradual pressure decrease In unloader pressure chamber
(2) towards the compressor stage inlet pressure level.
4 The pressure difference in unloader pressure chambers (2) and (4) causes the unloader
plunger (3) to move upwards. This upward movement forces unloader disc (6) to open
the compressor stage inlet.
5 Air compression and air delivery resume.
Modulating control
The modulation control is available as an option.
Function
To boost the compressor performance an adaptation of the standard unloader is made. The modulating
control valve can reduce the FAD (Free Air Delivery) down to 30% of the nominal FAD while maintaining
a pressure band of 0.5 bar (7 .3 psi). Besides FAD reduction, the consumed power also drops with
approximately 73% of the nominal power. When reducing the FAD, the SER (Specific Energy
Requirement) will increase up to 260% of nominal SER. Compared to machines which do NOT have a
Modulating Control Unloading Valve, maximum FAD will be 4% less and SER will be increased by 4%.
System setup
APF196927 21
,_ , __
Instruction book
Reference Designation
A Elektronikon regulator
B Unloader
C To air cooler
D Air receiver / Oil separator
E To I From oil cooler
Regulating system
The compressor is controlled by the Elektronikon®regulator (A).
/
The regulator keeps the net pressure within programmable pressure limits by automatically loading a~d
unloading the compressor depending on the air consumption. It also protects the compressor and momtors
components subject to service.
Unloading
lfthc air consumption is less than the air delivery of the compressor, the net pressure increases. When the
net pressure reaches the upper limit of the working pressure (unloading pressure), the following sequence
will occur.
Step Description
I
1 The load/ unload control valve (1) opens and connects air receiver (D) and unloader
pressure chamber (2).
The blow-off valve (5) opens and releases air from the air receiver (D). Both the air
receiver pressure and the unloader chamber (4) pressure drop.
2 Driven by the pressure difference in unloader pressure chambers (2) and (4), unloader
plunger (3) moves downwards. This downward movement forces the unloader disc (6)
to dose the compressor stage inlet.
3 The compressor stage keeps drawing in air through calibrated bypass holes in the
unloader disc (6) to maintain the unloading pressure level.
4 The air delivery stops, the air receiver (D) pressure reaches its stable unload pressure
level and air is being recirculated in the compressor.
The unload pressure level is necessary to guarantee the oil injection on a few critical
points (bearings, rotors, ...).
Loading
When ~e net pressure decreases to the lower limit of the working pressure (loading p ) th
followmg sequence will occur. ressure , e
20
mstrucuon oooK
-- ----- Jlila3 O>p«,
Outlet pressure ( 1)
Y11
"~
From vessel (2)
l~,1 ~-
~ P l18
B
PR
I
BN - - - -
59904D
The system consists of: the main components listed in following table (refer to 2 drawings above)
APF196927 23
2.4 Regulat ing system
Flow diagram
AIII I
I
t«-.:~~'.%1
'
/,
// / ......-==--::-,1
B: I
I
,
: / ·-:-14
I
598460
APF196927 19