Professional Documents
Culture Documents
Doka Its96 FL Tech Brochure 0718 PDF
Doka Its96 FL Tech Brochure 0718 PDF
Doka Its96 FL Tech Brochure 0718 PDF
ITS 96 FL
Concealed cam-action
door closer system
dormakaba ITS 96 / ITS 96 FL
Because of its compact design, the ITS 96 system can Offering proven EASY OPEN technology, the free-swing
be concealed for virtual invisibility within the door and function ensures exceptionally light door opening. dor-
frame, integrating inconspicuously with the overall makaba cam-action door closers with EASY OPEN
architectural ambience. technology feature a heart-shaped cam that significantly
reduces the opening resistance that has to be overcome,
Following the further development of the ITS 96 system almost as soon as the door is operated. Children, seniors
to create the ITS 96 FL, the same advantages have now and the physically disabled can thus open the door
been complemented with a free-swing function for fire without undue effort. However, it is not only this group of
and smoke check doors up to a passage width of 1400 users that benefits from the advantages of the rapidly
mm and a weight of 180 kg. This enhanced convenience decreasing opening force required – because this technol-
also contributes to providing barrier-free access in a ogy also generally ensures a significant reduction in effort
building. for maximum user friendliness.
20
10 Opening force
Closing force
0 ITS 96 FL free-swing door closer
0° 30° 60° 90° 120°
2
ITS 96 / ITS 96 FL
3
dormakaba ITS 96 / ITS 96 FL
ITS 96
515 (512)
440
20 400
20
12
3
10
76 (67 )
(42)
51
334 (320)
96 (93)
9 9
R8
C
ITS 96
ANSI 2-5
Made in
(32)
669G F
20
EN 3-6
40
LISTED
EN 1154
3 8 3-6 1 1 4
0432
105 (102)
352 (338)
Illustration shows the ITS 96, size 3 – 6 with UK standard spindle and G96 N20 arm and channel
Dimensions shown in ( ) = ITS 96, size 2 – 4 with UK standard spindle and G96 N20 arm and channel
ITS 96 FL
440
20 400
12
20
3
76
10
51
522
96
9 9
R8
+
ITS 96 FL
3W /120mA
EN 115 4
24 V DC
EN 3-6
Germany
40
20
Made in
3 8 3-6 1 41
0432
3 8 3-6 1 14
EN 115 5
-
105
540
ITS 96FL with standard UK spindle and G96 N20 arm and channel
4
ITS 96 / ITS 96 FL
Adjustment of settings
The functions of the ITS 96 can be
3 2
individually adapted to the local
conditions of each application. The
closing strength can be easily varied in
accordance with the door width via the approx. approx.
adjustment screw accessible from the 120°
1 80°
top. The closing speed and the latch 4 2 3
action can likewise be modified at any
time using adjustment screws at the
top, even after the door has been hung. 2 Fully controlled closing with
adjustable speed
3 Adjustable latch action
4 Cushioned limit stay
1 Screw for adjusting the closing strength
2 Valve for adjusting the closing speed
3 Valve for adjusting the latching speed
5
dormakaba ITS 96 / ITS 96 FL
Adjustment of settings
As the door is opened, the free-swing 3 2
function is activated from an opening
angle of >0°. This feature ensures that
the door is particularly easy to use, with
the only opening resistance emanating approx.
1 approx.
from the hinges. In the event of a fire or 120° 80°
power failure, the door is safely closed 5 2 4 3
by the door closer. The closing force can
be readily adapted to the door width
using an adjustment screw accessible 2 Fully controlled closing with adjustable
from above. The closing speed and the speed (non-powered)
latch action are likewise adjustable 3A
djustable latch action
from above, again with the closer in situ (non-powered)
and the door remaining hung. 1 Screw for adjusting the closing strength
2 Valve for adjusting the closing speed 4 Free-swing range
3 Valve for adjusting the latching speed 5 Cushioned limit stay
1 234 1 234
RM-N
ON
1
RMZ C C
2
230 VAC - -
3
B B
4
±10 %
T + T +
ITS 96 - -
G 96 EMF A A
12 3 11 10 2 14 RM-N RM-N
7 8 9 16 1 4
G 96 EMF
ITS 96
HT
B 10 A
N PE L
230 V AC
43 kΩ
RMZ
Recommended cabling:
I - Y (St) Y 2 x 2 x 0,6
6
ITS 96 / ITS 96 FL
G 96 N20
G 96 EMF
Applications and installation G 96 GSR
G 96 GSR-EMF.
ITS 96 2–4
ITS 96 3–6
ITS FL 3–6
with 1.5mm
extended spindle.
X=8,5 X=12
Reduced spindle
ITS 96 2–4
ITS 96 3–6
ITS 96 FL 3–6
* G 96 N arm cannot be
used with ITS96 reduced
spindle unit
Not suitable for G96N arm
spindle
ITS 96 2–4
ITS 96 3–6
ITS 96 FL 3–6
spindle
ITS 96 2–4
ITS 96 3–6
ITS 96 FL 3–6
13.5
10
Please check
dimensions carefully
12
16
13.5
16
10
20
20
20
Please check
12
dimensions carefully
8
ITS 96 / ITS 96 FL
Hold-open unit
Not for fire and smoke check doors.
For G 96 N
150°
75°
Hold-open range
For G 96 N20
approx. 120°
The RF hold-open unit enables doors to be securely held without any fall-back at
precisely the required position up to an opening angle of approx. 120°. The pull-off Hold-open range
force can be adjusted to any door situation. The RF mechanism is non-handed.
9
dormakaba ITS 96 / ITS 96 FL
31 145 440
min. 16
min. 54
(min. 44)
175 375
Illustration shows the ITS 96, size 3 – 6
Dimensions shown in ( ) = ITS 96, size 2 – 4
ITS 96 UK standard spindle closer with G 96 N slide channel in a timber door. Example: Anticlockwise-closing (ISO 6) door; mirror image
applies to clockwise-closing (ISO 5) doors. For fire doors min is 54mm (44mm)
20 145 440
min. 14
10
(46)
10
55
70 (73) 500
min. 54
=
(min. 44)
=
175 375
Illustration shows the ITS 96, size 3 – 6
Dimensions shown in ( ) = ITS 96, size 2 – 4
ITS 96 UK Standard spindle door closer with G 96 N20 slide channel in a timber door.
Example: Anticlockwise-closing (ISO 6) door; mirror image applies to clockwise-closing (ISO 5) doors. For fire doors min is 54mm (44mm)
145 1) 440
max. 16
ITS 96 door closer with G 96 N20 slide channel in an aluminium framed door. Example: Anticlockwise-closing (ISO 6) door;
mirror image applies to clockwise-closing (ISO 5) doors. 1)
Add 25 mm for aluminium profile frames with corner-angle reinforcement.
10
ITS 96 / ITS 96 FL
20 145 440
min. 14
24V DC
10
55 90 490
40
70
= 540
min. 50
=
175 375
ITS 96 UK standard spindle FL door closer with G 96 N20 slide channel in a timber door.
Example: Anticlockwise-closing (ISO 6) door; mirror image applies to clockwise-closing (ISO 5) doors.
24V DC
96 1) 484 x 40
175 1) 375
ITS 96 FL door closer with G 96 N20 slide channel in an aluminium framed door. Example: Anticlockwise-closing (ISO 6) door;
mirror image applies to clockwise-closing (ISO 5) doors. 1)
Add 25 mm for aluminium profile frames with corner-angle reinforcement.
11
dormakaba ITS 96 / ITS 96 FL
31
527
30
The slide channel assembly enables the In the event of an alarm or a fault in the Specification text
door to be held open securely at a power supply, the hold-open is released ITS 96 ... door closer (see pages 4 and 5)
pre-selected position without fall-back. and the door is closed by the door closer. with G 96 EMF K8/K12 slide channel
The hold-open point can be adjusted The release force for the hold-open assembly, with integrated 24 V DC
within an opening angle of approx. 80° mechanism can be adjusted without electro-mechanical hold-open, tested
and 120°. tools and is rated to ensure that the to EN 1155. Hold-open point (80° – 120°)
door can also be easily released and release force adjustable.
manually.
Note: Approved by the Institute for Building
The hold-open point also constitutes Technology, Berlin, for general use in
the max. door opening angle (position The G 96 EMF slide channel assembly hold-open systems.
door stop accordingly). comprises the arm, slide channel, slide
block, electro-mechanical hold-open
Version
unit and fixing screws, and can be
☐☐ LH (ISO 6) K8/K12
Technical data combined with both door closer sizes in
☐☐ RH (ISO 5) K8/K12
the ITS 96 range.
In the case of particularly large and
Operating voltage: 24 V DC, ± 15% Make
heavy doors (over 1250 mm), we
Power input: 1.4 W recommended that EM hold-open ITS 96 EMF
magnets be employed instead of the
Rated for
electro-mechanical hold-open unit.
continuous duty: 100% ED
Release force: Adjustable
2x 43 k Ω
RM-N
1 234 1 234
RM-N
ON
1
RMZ C C
2
230 VAC - -
3
B B
4
±10 %
T + T +
ITS 96 - -
G 96 EMF A A
12 3 11 10 2 14 RM-N RM-N
7 8 9 16 1 4
G 96 EMF
ITS 96
HT
B 10 A
N PE L
230 V AC
43 kΩ
RMZ
Recommended cabling:
I - Y (St) Y 2 x 2 x 0,6
12
ITS 96 / ITS 96 FL
Power supply 24 V DC
90 527
20 211 211
min. 14
30
14
98 (89)
55 (46)
10
40
(32) 96 (99) 300x40 (286x32)
70 (73) 500
min.54
(min.44)
=
Please check
=
dimensions carefully
175 375
Illustration shows the ITS 96, size 3 – 6
Dimensions shown in ( ) = ITS 96, size 2 – 4
ITS 96 UK standard spindle door closer with G 96 EMF slide channel assembly in a timber door.
Example: Anticlockwise-closing (ISO 6) door; mirror image applies to clockwise-closing (ISO 5) doors.
Power supply 24 V DC
90 1) 527
31
20 211 211
max. 16
12
30
96 (87)
175 1) 375
ITS 96 door closer with G 96 EMF slide channel assembly in an aluminium framed door.
Example: Anticlockwise-closing (ISO 6) door; mirror image applies to clockwise-closing (ISO 5) doors.
1)
Add 25 mm for aluminium profile frames with corner-angle reinforcement.
13
dormakaba ITS 96 / ITS 96 FL
The slide channel with integral door The G 96 GSR slide channel door An overload release protects the door
co-ordinator for pairs of doors ensures co-ordinator features a push rod co-ordinator and the door set from
that the active leaf always closes after clamping system. As this system damage. The G 96 GSR can be
the inactive leaf. operates independently of door closer combined with both door closer sizes
hydraulics, it offers maximum safety of the ITS 96 and ITS 96 FL range.
and reliability.
Version/Function Door width (mm) Door leaf thickness min. Closer size ITS 96
(mm)
GSR
Door co-ordinator 1450 – 2200 40 2–4
1450 – 2800 50 3–6
Connecting tube
14
ITS 96 / ITS 96 FL
Example application
ITS 96
ITS 96
G 96GSR
15
dormakaba ITS 96 / ITS 96 FL
This door co-ordinator not only ensures In the event of an alarm or a fault in the The G 96 GSR-EMF slide channel door
the correct closing sequence of pairs of power supply, the hold-open is released co-ordinator can be combined with both
doors, but also allows the door leaves to and the door is closed by the door closer. door closer sizes of the ITS 96 range.
be individually held open by an electro- The release is initiated by a signal from In the case of particularly large and
mechanical device. The hold-open point external smoke detectors (e.g. RMZ) or heavy doors (over 2500 mm), we
for both door leaves lies between other fire alarm. recommended that EM hold-open
approx. 80° and 120°. The release force for the hold-open magnets be employed instead of the
mechanism can be adjust-ed without electro-mechanical hold-open unit.
tools and is rated to ensure that the
door can also be easily released
manually.
Note:
The hold-open point also constitutes
the max. door opening angle – position
door stop accordingly.
Version/Function Door width (mm) Door leaf thickness min. (mm) Closer size ITS 96
GSR-EMF
Door-coordinator and 1450 – 2200 40 2–4
hold-open in both leaves 1450 – 2800 50 3–6
Connecting tube
16
ITS 96 / ITS 96 FL
= Door stop
RM-N
ITS 96
ITS 96
G 96GSR-EMF
ITS 96
Active leaf G 96GSR-EMF
ITS 96 Inactive leaf
2x 43 k Ω
2x 12 1 kΩ 2x 12 1 k Ω
ON
1
2
1 234 1 234
3
4
C C
B - B -
2x 12 1 kΩ 2x 12 1 k Ω
T + T +
- -
1 234 1 234
C A C A
B - B -
1 234 1 234
C T C + T +
B - B - - -
12 3 11 10 2 14
T + T
RM-N + RM-N
A A
12 3 11 10 2 14 - -
A A
12 3 11 10 2 14
RM-N RM-N
7 8 9 16 1 4
RM-N RM-N
7 8 9 16 1 4
7 8 9 16 1 4 EMF
G 96 GSR-EMF
ITS 96
EMF G9 6 GSR-EMF G9 6 GSR-EMF
EMF
HT ITS 96 ITS 96
HT HT B 10 A
B 10 A
N PE L Recommended cabling:
I - Y (St) Y 2 x 2 x 0,6
B 10 A 230 V AC
N PE L
43 kΩ N PE L
RMZ
230 V AC
121 k Ω
RMZ 230 V AC
121 k Ω
RMZ
17
dormakaba ITS 96 / ITS 96 FL
Power supply 24 V DC
31 (for EMF only)
901) 512
12
96 (87)
Active leaf
min. 750 mm
Connecting frame
(see page 33)
31
Active leaf
min. 1200 mm
18
ITS 96 / ITS 96 FL
527 901)
211 211 110 1)
Inactive leaf
min. 700 mm
If the inactive leaves are particularly narrow (less than
700 mm), please discuss the installation possibilities
with dormakaba and/or the relevant profile manufacturer.
1450 – 2800
(1400 – 2200)
375 175 1)
F When installed in fire and smoke check doors, ensure that the MK 397 carry bar is also fitted.
19
WN 054174 51532, 05/17, ITS 96 / ITS 96 FL, GB, x. XX.01/18
Subject to change without notice
E: info.gb@dormakaba.com