iGEM Error codes and solutions

Error Type Classification Description

Log A Error/event is only logged.

TERMINATION B Error/event is logged as specified above and filling is terminated.

SEMI-FATAL C Error/event is logged as specified above, filling is terminated and current


dispenser side is closed.

FULLY-FATAL D Error/event is logged as specified above, filling is terminated and both dispenser
sides are closed.

CATASTROPHIC E Error/event is logged as specified above, filling is terminated and both dispenser
sides are closed, power cycle must be done.

INDICATION F Error/event is not logged, but certain message on display gives information
about error.

DISABLED G Error is not logged, no action.

COUNT H Error is not logged, error counter is increased.

No. Error/Event Description Solution Classification


16 Overflow Limit Reached Limit for suppressed overflow has been Increase value in F19.13. B
reached Clean proportional valves.
Exchange proportional
valves.
20 Display Read back Error Configured maximum number of display Check display cable. B
read back errors Exchange display cable.
has been reached ( -> F.17.02 ) Exchange display board.
Exchange iGEM.
30 POS Communication Lost No poll from POS for time exceeding Check settings in F20.00 C
configured maximum and F20.01.
offline time -> F23.02
Increase value in F23.02.
Verify switch SW3.
Verify jumper settings.
Verify POS settings.
Check wiring.
Exchange iGEM.
41 Motor feedback Errors from motor Check motor connection. B
If a dispenser disable motor feedback, Reset iGEM.
F43.00=0 Check belt tension.
Exchange motor.
Check pumping unit
pressure.
50 Error on WIP in use Errors from WIP used in Transaction ( -> Check for leakage. B
F17.00 ) Exchange check valve.
Wayne Fueling Systems AB
Hanögatan 10, Box 50559 • SE-202 15 Malmö, Sweden • Phone: +46 40 36 06 75 • www.wayne.com

Your Total Retail Solutions ProviderSM


iGEM Error codes and solutions
Clean magnetic wheel.
Exchange magnetic wheel.
Exchange WIP.
Exchange meter.
58 Comm failure with WIP in WIP used in transaction didn’t respond Check wiring to WIP. B
use on re-transmission. Exchange ISB.
Exchange WIP cable.
Exchange WIP.
Exchange iGEM.

70 No Flow Timeout Filling was started but no fuel has been Verify nozzle function. B
dispensed for configurable time Verify programming F17.03
( -> F17.03 ) Verify fuel tank level.
Exchange proportional
valve.
Exchange iGEM
72 Flow Lost Timeout Flow was lost for configured maximum Verify timeout settings. B
time ( -> F17.03 & F54.10 ) Verify fuel tank levels.

Wayne Fueling Systems AB


Hanögatan 10, Box 50559 • SE-202 15 Malmö, Sweden • Phone: +46 40 36 06 75 • www.wayne.com

Your Total Retail Solutions ProviderSM