Vickers®

Transmissions

Service Parts Information

Transmission Supercharge Pumps


TA1515V-1**-3030-1*-**-(C)****10L

Revised 11/1/85 M-2006-S


386524 Piston Outlet Port Ring
Cover Screw
Connections Capacity
388262 1
320353 Plug 386946 2 1278-C
386936 3
386937 K 4
Y 154129 O-Ring 1278-A
407518 5
386939 6
1278-D
389460 Spring 410309 7

Y 154129 O-Ring
Relieve Valve Pressure Screw
Setting Setting 307354 Plug
A 250 252886
B 500
2280
C 750
D 1000 373117 Shim
2282
E 1250 Screw (4 req’d) 7075 Plug
F 1500 (See table)
Torque to 40  5 lb. ft.
G 1750
H 2000 2281 2706 Seat
J 2250 82800 Poppet
K 2500 Spring (See table)
373118 Shim

Flow Outlet Port


Cover
Rate Connections
379543 2
379545 3
376605 4
P
239766 379547 5
Spring 379549 6
379551 7
388835 8
372851 2
Relieve Valve Pressure Control 372852 3
Setting Setting Valve S/A 372853 4
A 250 psi 229613 372854 5 T
B 500 psi 233018 372855 6
C 750 psi 232794 372856 7
D 1000 psi 232795 388838 8
E 1250 psi 232796
F 1500 psi 232797
G 1750 psi 232798
H 2000 psi 232799
J 2250 psi 233019
K 2500 psi 233020

155023 186580 Plug


Snap Ring (2 req’d)
Ring Screw (4 req’d)
Capacity Torque 40  5 lb. ft. Y 154129
1, 2, 3 1278-B O-Ring
4, 5 1278-C (2req’d) F Also included in Cartridge Kit
6, 7 1278-A
Y Included in 923548 Seal Kit
Ring Rotor Vane Kit Ring
Pin Cart.
Capacity (12 Vanes)
USgpm Kit
Included in Cartridge Kit
3 317681 923499 317676 231042
4 317677
417297 923500 39640
5 317678 923928
6 355641
417212 923501 16662
7 331813 923812

Std. Outlet Port


Screw
Cover Connections
372863 P
1278
372865 S

Inlet Port Connection


Code Body (V10)
Omitted(s) 395643
T 402652
YF 199823
O-Ring
YF 199822
O-Ring 345262
Spring
Screw (See table) 374343
Torque to 40  5 lb. ft. Pressure Plate S/A
Model Code

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

1 Transmission Pump 7 Relief Valve Setting 12 Vane Pump Inlet Position


4500 psi (std. omit) C - Inlet 180° opposite TA1515
2 Double Pump Size 3030 - 3000 psi case drain
8 Supercharge Inlet Omitted - Inlet inline with TA1515 case
drain (std.)
3 Co-existing Version 1 - left hand
- omit for right hand 13 Outlet Port Positions Vane Pump
V - Aux. V10
VF - Aux. V10 with flow control (Viewed from Cover End)
9 Control Description
valve cover A - Opposite inlet
VP - Aux. V10 with priority cover Right or left hand pintle location is B - 90° C’clockwise from inlet
determined by viewing pump from input C - Inline with inlet
4 Pump Shaft Extension shaft end with case drain positioned up. D - 90° Clockwise from inlet
1 - Splined
10 Inlet Port Connection - Vane Pump 14 Flow Rate thru Orifice in Cover
5 Control Options P - 1” NPT 2 - 2 USgpm 5 - 5 USgpm
T - 1.1875-12 standard thread 3 - 3 USgpm 6 - 6 USgpm
L - Left hand
Omitted - 1,3125-12 standard thread 4 - 4 USgpm 7 - 7 USgpm
B - Double pintles
(stand. omit) 8 - 8 USgpm
- omit for right hand
11 Ring Capacity @1200 rpm 15 Vane Pump Relief Valve Setting
6 Port Connection Double Piston
A - 250 psi F - 1500 psi
Pumps 1 - 1 USgpm 5 - 5 USgpm
2 - 2 USgpm 6 - 6 USgpm B - 500 psi G - 1750 psi
S - .875 - 14 standard thread C - 750 psi H - 2000 psi
3 - 3 USgpm 7 - 7 USgpm
- 1.0625 - 12 standard thread 4 - 4 USgpm D - 1000 psi J - 2250 psi
(std - omit) E - 1250 psi K - 2500 psi
Outlet Port Connections
16 Outlet Port Connections
Flow Control Cover Priority Valve Cover
Standard (See table below)
Code Primary Secondary Tank
Cover Pressure Tank
Outlet Outlet Outlet 17 Design
9/16-18 3/4-16 9/16-18 18 Rotation (Omit for right hand)
K St. Thd. St. Thd. St. Thd.
V10P V10P V10P L - Left hand
V2010P V2010P V2010P
1/2-NPT
V10
V2010
P
3/4-NPT 3/4-16 1/2-NPT
V20 V20 V10
V2020 V2010 V2010
3/4-16
St. Thd.
S
V10
V2010
3/4-16 3/4-16
T St. Thd. St. Thd.
V10 V10
V2010 V2010
7/8-14
Y St. Thd.
V10
V2010

For satisfactory service life of these components, use full flow filtration to provide fluid which meets ISO cleanliness code 19/15