Download as pdf or txt
Download as pdf or txt
You are on page 1of 31

DESIGN REPORT FOR CONTROL ROOM

DESIGN REPORT OF SECURITY CABIN

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

Contents
1 GENERAL .......................................................................................................................................................................... 3
1.2 SCOPE ............................................................................................................................................................................... 3
1.2 SITE INFORMATION........................................................................................................................................................... 3
1.2.1 SITE LOCATION ............................................................................................................... ...................................... 3
1.2.2 WIND PRESSURE ............................................................................................................... .................................... 3
2 CODES, STANDARDS AND REFERENCES ............................................................................................................................. 3
3 LOADS AND LOAD COMBINATIONS ................................................................................................................................... 4
3.2 DEAD LOADS ..................................................................................................................................................................... 4
3.2 IMPOSED LOADS ............................................................................................................................................................... 4
3.2 WIND LOADS ..................................................................................................................................................................... 4
3.2 EARTHQUAKE LOADS ........................................................................................................................................................ 5
3.2 BASIC LOAD CASES ............................................................................................................................................................ 6
3.2 LOAD COMBINATIONS ...................................................................................................................................................... 6
4 DESIGN METHODOLOGY ................................................................................................................................................... 7
4.2 GENERAL........................................................................................................................................................................... 7
4.2 MATERIALS ....................................................................................................................................................................... 7
4.3 DESIGN OF STRUCTURAL MEMBERS ................................................................................................................................. 7
5 STAAD MODELLING........................................................................................................................................................... 9
5.2 STAAD INPUT AND OUTPUT ............................................................................................................................................ 11
5.2 SUPPORT RECTIONS ....................................................................................................................................................... 21
5.2 FOOTING DESIGN...............................................................................................................................................................22
5.4 BASE PLATE DESIGN........................................................................................................................................................... 24

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

1 GENERAL
1.1 SCOPE
The scope of this design basis report (DBR) is intended to cover the design of Main Control Room (MCR) and its
foundations.

This document covers the general description of structural framing system, applicable design codes and standards,
specific design criteria, design loads and combinations, design methodology and characteristics of construction
materials to be adopted for the project.

This DBR has been developed on the basis of the relevant parts of the technical specification and subsequent
technical discussions with the client. In absence of any particular aspect of structural design of this project’s
components in this DBR, relevant Indian standards will be followed. The requirements that have not been listed
here but are otherwise required to complete the work shall be as per NIT specifications.

1.2 SITE INFORMATION


1.2.1 SITE LOCATION
The project site is located in Gujrat.

1.2.2 WIND PRESSURE


As per IS: 875 (Part-3)-1987 maximum wind speed is considered as 50m/s.

2 CODES, STANDARDS AND REFERENCES

S.No Code Description

1 IS: 875 (Part-1)-1987 Code of practice for Design Loads (Other than Earthquake)
for buildings and Structures – Unit Weights of Buildings
Materials and Stored Materials.

2 IS: 875 (Part-2)-1987 Code of practice for Design Loads (Other than Earthquake)
for buildings and Structures – Imposed loads.

3 IS: 875 (Part-3)-1987 Code of practice for Design Loads (Other than Earthquake)
for buildings and Structures – Wind loads.

4 IS: 1786 – 2008 Specification for High Strength Deformed Steel Bars and
Wires for concrete Reinforcement.

5 I2: 800 – 2007 Code of practice for general construction in steel.

6 IS:456-2000 Code of Practice for Plain and reinforced concrete.

7 IS: 13920-1993 Code of practice for Ductile detailing of reinforced concrete


structures subject to seismic forces.

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

8 IS:2062-1999 Steel for General structural purposes – Specification.

9 SP: 34 Hand Book on concrete reinforcement and detailing.

10 IS:1893 (Part-1) - 2002 Criteria for Earthquake resistant design of structures.

3 LOADS AND LOAD COMBINATIONS


3.1 DEAD LOADS

i) Weight of the materials used in the construction will be considered as follows:


a. RCC members : 25.0 kN/m³
b. Plain concrete members : 24.0 kN/m³
c. Soil : 18.0 kN/m³
d. Water : 10.0 kN/m³
ii) Dead loads per unit area
a. Roofing material : 0.15 kN/m²

3.2 IMPOSED LOADS

a. Roof Load : 0.75 kN/m²

3.3 WIND LOADS

The structure shall be designed for wind forces in accordance with IS:875 (part-3) and as specified in this
document. The evaluation of the design wind speed and pressure will be made on the basis of the following
parameters:
Basic wind speed = 50 m/s

Probability factor (Risk coefficient), k1 = 1.0


Taken from the below table of IS 875 part 3

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

Terrain category = 2

Structure classification based on structure = Class B

Terrain, height and structure size based factor, k2 = 1.00,


Taken from the below table of IS 875 Part 3,

Topography factor, k3 = 1

Importance factor for cyclonic region, k4 = 1.15

The wind analysis shall consider the wind direction relative to the structure and both external and internal
pressure as applied to the windward and leeward sides of the structure.

3.4 EARTHQUAKE LOADS


The seismic coefficients based on the geographical and structural parameters are considered as follows:

a. Seismic zone : Zone V


b. Zone factor : 0.36
c. Importance factor: 1.0
d. Response reduction factor : 5.0
e. Soil type : II

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

3.5 BASIC LOAD CASES


The following basic load cases shall be considered for the analysis;
Dead Load : DL

Imposed Load : LL

Wind load : WL

Seismic load : EQ seismic loads have been considered in accordance with provisions
given in is 1893:2002

3.6 LOAD COMBINATIONS


Load combination for design shall be the one that induces the maximum forces and effects and consequently the
maximum stress from the following combinations of loads
Limit State of Collapse Limit State of Serviceability
Load Combination
DL IL WL EL DL IL WL EL
DL + LL 1.5 1.5 - - 1.0 1.0 - -
DL+WL 1.5 - 1.5 - 1.0 - 1.0 -
Dl + EQ 1.5 - - 1.5 1.0 - - 1.0
DL+WL 0.9 - 1.5 - - - - -
Dl + EQ 0.9 - - 1.5 - - - -

DL + LL +WL 1.2 1.2 1.2 - 1.0 0.8 0.8 -


DL + LL + EQ 1.2 1.2 - 1.2 1.0 0.8 - 0.8

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

4 DESIGN METHODOLOGY
3D space frame analysis using STAAD.Pro, which utilizes finite element technique to carry out the analysis,
is employed. The advanced solver processes the member and element properties, based on load combinations
and support conditions to arrive at the stiffness and load matrices. The solver further uses matrix method to
determine the nodal displacements, member forces/stresses, element forces/stresses and support reactions,
which will be further utilized in the design of the structural members. However, the design of the elements will
be carried out either manually or by standardized excel sheets or in house software packages or using STAAD
Pro software design modules.

4.1 GENERAL
The structure is planned to be steel frame structure. The building consists of Ground floor only with min. floor
heights of 3.6m. Foundations shall be isolated Pad footings based on site requirement.

4.2 MATERIALS
Concrete Grade: M25

Reinforcement Steel: Steel reinforcement shall be High Strength Deformed Bars of grade Fe-500D of TMT
Type conforming to IS: 1786-2008

Nominal cover to reinforcement:

1. Footing : 50 mm
2. Pedestal : 40 mm
3. Beams : 25 mm
4. Slabs : 15 mm

4.3 DESIGN OF STRUCTURAL MEMBERS


The member forces and support reactions as arrived through the analysis are utilized in the design of
structural members as per IS 800: 2007. All designs will be carried out using the limit state method of
design.

As per this method, the structure will be designed for all possible limit states of collapse and
serviceability mentioned in clause 3.6.

Foundation: The foundations are designed for support reactions of all un-factored loads for
corresponding partial factors of safety for fixed condition. In-house programs are used for the design.

Columns: Design results from STAAD design modules for fixed supports at foundation level for the
severest case among the load combinations.

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

Beams: Design results from STAAD design modules for the severest case among the load
combinations. Beams are grouped according to span, cross section and support conditions.

Slabs: Slabs are designed as slab on grade as per the IS-456: 2000 for DL+LL. In-house programs are
used for the design.

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

5 STAAD MODELLING

Column Numbers

Roof Beam

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

3D Model

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

5.1 STAAD INPUT AND OUTPUT

PAGE NO. 1

****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.33 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= OCT 18, 2023 *
* Time= 12:14:47 *
* *
* USER ID: *
****************************************************

1. STAAD SPACE
INPUT FILE: F:\PROJECTS\HARSHITBHAI SAVALIYA (KASOL ENERGY)\SECURITY CABIN\STAAD
MODEL\SECURITY CABIN.STD
2. START JOB INFORMATION
3. ENGINEER DATE 15-MAY-23
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 3.54; 2 0 3.325 3.54; 3 3.54 0 3.54; 4 3.54 3.325 3.54; 5 0 0 0; 6 0 3 0
9. 7 3.54 0 0; 8 3.54 3 0; 9 0 3.24375 2.655; 10 0 3.1625 1.77
10. 11 0 3.08125 0.885; 12 3.54 3.24375 2.655; 13 3.54 3.1625 1.77
11. 14 3.54 3.08125 0.885
12. MEMBER INCIDENCES
13. 1 1 2; 2 3 4; 3 5 6; 4 7 8; 5 6 8; 6 2 4; 7 2 9; 8 4 12; 9 9 10; 10 10 11
14. 11 11 6; 12 12 13; 13 13 14; 14 14 8; 15 11 14; 16 10 13; 17 9 12
15. DEFINE MATERIAL START
16. ISOTROPIC STEEL
17. E 2.05E+008
18. POISSON 0.3
19. DENSITY 76.8195
20. ALPHA 1.2E-005
21. DAMP 0.03
22. TYPE STEEL
23. STRENGTH RY 1.5 RT 1.2
24. ISOTROPIC CONCRETE
25. E 2.17185E+007
26. POISSON 0.17
27. DENSITY 23.5616
28. ALPHA 1E-005
29. DAMP 0.05
30. TYPE CONCRETE
31. STRENGTH FCU 27579
32. END DEFINE MATERIAL
33. CONSTANTS
34. MATERIAL STEEL ALL
35. MEMBER PROPERTY TATASTRUCTURA
36. 5 TO 14 TABLE ST 80X80X4.0SHS
37. 15 TO 17 TABLE ST 60X60X4.0SHS
38. 1 TO 4 TABLE ST 100X100X5.0SHS

STAAD SPACE -- PAGE NO. 2

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

39. SUPPORTS
40. 1 3 5 7 FIXED
41. MEMBER OFFSET
42. 15 TO 17 START 0 0.025 0
43. 15 TO 17 END 0 0.025 0
44. DEFINE 1893 LOAD
45. ZONE 0.36 RF 4 I 1 SS 2 ST 2 DM 0.04 PX 0.1567 PZ 0.1567
46. SELFWEIGHT 1
47. MEMBER WEIGHT
48. 5 6 15 TO 17 UNI -0.136
49. 5 6 UNI -0.068
50. 1 TO 4 UNI -0.27
51. LOAD 1 LOADTYPE NONE TITLE EQ (+X)
52. 1893 LOAD X 1
53. PERFORM ANALYSIS

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 14 NUMBER OF MEMBERS 17


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 4

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 8/ 3/ 18 DOF


TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 60
TOTAL LOAD COMBINATION CASES = 0 SO FAR.
SIZE OF STIFFNESS MATRIX = 2 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.0/ 202499.8 MB

*********************************************************
* *
* TIME PERIOD FOR X 1893 LOADING = 0.15670 SEC *
* SA/G PER 1893= 2.676, LOAD FACTOR= 1.000 *
* VB PER 1893= 0.1204 X 10.07= 1.21 KN *
* *
*********************************************************

54. CHANGE
55. LOAD 2 LOADTYPE NONE TITLE EQ (-X)
56. 1893 LOAD X -1.

STAAD SPACE -- PAGE NO. 3

57. PERFORM ANALYSIS

*********************************************************
* *
* TIME PERIOD FOR X 1893 LOADING = 0.15670 SEC *
* SA/G PER 1893= 2.676, LOAD FACTOR=-1.000 *
* VB PER 1893= 0.1204 X 10.07= -1.21 KN *
* *

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

*********************************************************

58. CHANGE
59. LOAD 3 LOADTYPE NONE TITLE EQ (+Z)
60. 1893 LOAD Z 1
61. PERFORM ANALYSIS

*********************************************************
* *
* TIME PERIOD FOR Z 1893 LOADING = 0.15670 SEC *
* SA/G PER 1893= 2.676, LOAD FACTOR= 1.000 *
* VB PER 1893= 0.1204 X 10.07= 1.21 KN *
* *
*********************************************************

62. CHANGE
63. LOAD 4 LOADTYPE NONE TITLE EQ (-Z)
64. 1893 LOAD Z -1.
65. PERFORM ANALYSIS

STAAD SPACE -- PAGE NO. 4

*********************************************************
* *
* TIME PERIOD FOR Z 1893 LOADING = 0.15670 SEC *
* SA/G PER 1893= 2.676, LOAD FACTOR=-1.000 *
* VB PER 1893= 0.1204 X 10.07= -1.21 KN *
* *
*********************************************************

66. CHANGE
67. LOAD 5 LOADTYPE DEAD TITLE DL
68. SELFWEIGHT Y -1
69. MEMBER LOAD
70. 15 TO 17 UNI GY -0.136
71. 5 6 UNI GY -0.068
72. 1 TO 4 UNI GY -0.27
73. LOAD 6 LOADTYPE LIVE TITLE LL
74. MEMBER LOAD
75. 15 TO 17 UNI GY -0.68
76. 5 6 UNI GY -0.34
77. LOAD 7 LOADTYPE WIND TITLE WIND UP +X (-CPI 0.5)
78. MEMBER LOAD
79. 5 6 15 TO 17 UNI GY 0.65
80. MEMBER LOAD
81. 1 3 UNI GX 3.08
82. 2 4 UNI GX -0.64
83. 1 2 UNI GZ 0.27
84. 3 4 UNI GZ -0.27
85. LOAD 8 LOADTYPE WIND TITLE WIND UP -X (-CPI 0.5)
86. MEMBER LOAD
87. 5 6 15 TO 17 UNI Y 0.65
88. MEMBER LOAD
89. 2 4 UNI GX -3.08

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

90. 1 3 UNI GX 0.64


91. 1 2 UNI GZ 0.27
92. 3 4 UNI GZ -0.27
93. LOAD 9 LOADTYPE WIND TITLE WIND UP +Z (-CPI 0.5)
94. MEMBER LOAD
95. 5 6 15 TO 17 UNI Y 0.65
96. MEMBER LOAD
97. 3 4 UNI GZ 3.08
98. 1 2 UNI GZ -0.64
99. 2 4 UNI GX 0.27
100. 1 3 UNI GX -0.27
101. LOAD 10 LOADTYPE WIND TITLE WIND UP -Z (-CPI 0.5)
102. MEMBER LOAD
103. 5 6 15 TO 17 UNI GY 0.65
104. MEMBER LOAD
105. 1 2 UNI GZ -3.08
106. 3 4 UNI GZ 0.64
107. 2 4 UNI GX 0.27
108. 1 3 UNI GX -0.27
109. LOAD 11 LOADTYPE WIND TITLE WIND UP +X (+CPI 0.5)
110. MEMBER LOAD

STAAD SPACE -- PAGE NO. 5

111. 5 6 15 TO 17 UNI GY 1.95


112. MEMBER LOAD
113. 1 3 UNI GX 0.514
114. 2 4 UNI GX 1.927
115. 3 4 UNI GZ -2.827
116. 1 2 UNI GZ 2.827
117. LOAD 12 LOADTYPE WIND TITLE WIND UP -X (+CPI 0.5)
118. MEMBER LOAD
119. 5 6 15 TO 17 UNI GY 1.95
120. MEMBER LOAD
121. 2 4 UNI GX -0.514
122. 1 3 UNI GX -1.927
123. 1 2 UNI GZ 2.827
124. 3 4 UNI GZ -2.827
125. LOAD 13 LOADTYPE WIND TITLE WIND UP +Z (+CPI 0.5)
126. MEMBER LOAD
127. 5 6 15 TO 17 UNI GY 1.95
128. 3 4 UNI GZ 0.514
129. 1 2 UNI GZ 1.927
130. 2 4 UNI GX 2.827
131. 1 3 UNI GX -2.827
132. LOAD 14 LOADTYPE WIND TITLE WIND UP -Z (+CPI 0.5)
133. MEMBER LOAD
134. 5 6 15 TO 17 UNI GY 1.95
135. 1 2 UNI GZ -0.514
136. 3 4 UNI GZ -1.927
137. 2 4 UNI GX 2.827
138. 1 3 UNI GX -2.827
139. *LOAD COMB 101 1.0DL+1,0LL
140. *5 1.0 6 1.0
141. *LOAD COMB 102 1.0DL+1.0WL+X(CP=-0.5)
142. *5 1.0 7 1.0
143. *LOAD COMB 103 1.0DL+1.0WL-X(CP=-0.5)
144. *5 1.0 8 1.0
145. *LOAD COMB 104 1.0DL+1.0WL+Z(CP=-0.5)
146. *5 1.0 9 1.0
147. *LOAD COMB 105 1.0DL+1.0WL-Z(CP=-0.5)
148. *5 1.0 10 1.0
149. *LOAD COMB 110 1.0DL+1.0EQ(+X)

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

150. *5 1.0 1 1.0


151. *LOAD COMB 111 1.0DL+1.0EQ(-X)
152. *5 1.0 2 1.0
153. *LOAD COMB 112 1.0DL+1.0EQ(+Z)
154. *5 1.0 3 1.0
155. *LOAD COMB 113 1.0DL+1.0EQ(-Z)
156. *5 1.0 4 1.0
157. *LOAD COMB 114 1.0DL+0.8LL+0.8(WL+X(CP=-0.5))
158. *5 1.0 6 0.8 7 0.8
159. *LOAD COMB 115 1.0DL+0.8LL+0.8(WL-X(CP=-0.5))
160. *5 1.0 6 0.8 8 0.8
161. *LOAD COMB 116 1.0DL+0.8LL+0.8(WL+Z(CP=-0.5))
162. *5 1.0 6 0.8 9 0.8
163. *LOAD COMB 117 1.0DL+0.8LL+0.8(WL-Z(CP=-0.5))
164. *5 1.0 6 0.8 10 0.8
165. *LOAD COMB 122 1.0DL+0.8LL+0.8EQ(+X)
166. *5 1.0 6 0.8 1 0.8

STAAD SPACE -- PAGE NO. 6

167. *LOAD COMB 123 1.0DL+0.8LL+0.8EQ(-X)


168. *5 1.0 6 0.8 2 0.8
169. *LOAD COMB 124 1.0DL+0.8LL+0.8EQ(+Z)
170. *5 1.0 6 0.8 3 0.8
171. *LOAD COMB 125 1.0DL+1.0WL+X(CP=+0.5)
172. *5 1.0 11 1.0
173. *LOAD COMB 126 1.0DL+1.0WL-X(CP=+0.5)
174. *5 1.0 12 1.0
175. *LOAD COMB 127 1.0DL+1.0WL+Z(CP=+0.5)
176. *5 1.0 13 1.0
177. *LOAD COMB 128 1.0DL+1.0WL-Z(CP=+0.5)
178. *5 1.0 14 1.0
179. *LOAD COMB 129 1.0DL+0.8LL+0.8(WL+X(CP=+0.5))
180. *5 1.0 6 0.8 11 0.8
181. *LOAD COMB 130 1.0DL+0.8LL+0.8(WL-X(CP=+0.5))
182. *5 1.0 6 0.8 12 0.8
183. *LOAD COMB 131 1.0DL+0.8LL+0.8(WL+Z(CP=+0.5))
184. *5 1.0 6 0.8 13 0.8
185. *LOAD COMB 132 1.0DL+0.8LL+0.8(WL-Z(CP=+0.5))
186. *5 1.0 6 0.8 14 0.8
187. *LOAD COMB 314 1.0DL+1.0LL+1.0(WL+X(CP=-0.5))
188. *5 1.0 6 1.0 7 1.0
189. *LOAD COMB 315 1.0DL+1.0LL+1.0(WL-X(CP=-0.5))
190. *5 1.0 6 1.0 8 1.0
191. *LOAD COMB 316 1.0DL+1.0LL+1.0(WL+Z(CP=-0.5))
192. *5 1.0 6 1.0 9 1.0
193. *LOAD COMB 317 1.0DL+1.0LL+1.0(WL-Z(CP=-0.5))
194. *5 1.0 6 1.0 10 1.0
195. *LOAD COMB 322 1.0DL+1.0LL+1.0EQ(+X)
196. *5 1.0 6 1.0 1 1.0
197. *LOAD COMB 323 1.0DL+1.0LL+1.0EQ(-X)
198. *5 1.0 6 1.0 2 1.0
199. *LOAD COMB 324 1.0DL+1.0LL+1.0EQ(+Z)
200. *5 1.0 6 1.0 3 1.0
201. *LOAD COMB 325 1.0DL+1.0LL+1.0EQ(-Z)
202. *5 1.0 6 1.0 4 1.0
203. *LOAD COMB 330 1.0DL+1.0LL+1.0(WL+X(CP=+0.5))
204. *5 1.0 6 1.0 11 1.0
205. *LOAD COMB 331 1.0DL+1.0LL+1.0(WL-X(CP=-0.5))
206. *5 1.0 6 1.0 12 1.0
207. *LOAD COMB 332 1.0DL+1.0LL+1.0(WL+Z(CP=+0.5))
208. *5 1.0 6 1.0 13 1.0
209. *LOAD COMB 333 1.0DL+1.0LL+1.0(WL-Z(CP=-0.5))

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

210. *5 1.0 6 1.0 14 1.0


211. **************************************************************
212. ***********STRENGTH************************************
213. ***********************************************
214. LOAD COMB 201 1.5DL+1.5LL
215. 5 1.5 6 1.5
216. LOAD COMB 202 1.5(DL+WL+X(CP=-0.5))
217. 5 1.5 7 1.5
218. LOAD COMB 203 1.5(DL+WL-X(CP=-0.5))
219. 5 1.5 8 1.5
220. LOAD COMB 204 1.5(DL+WL+Z(CP=-0.5))
221. 5 1.5 9 1.5
222. LOAD COMB 205 1.5(DL+WL-Z(CP=-0.5))

STAAD SPACE -- PAGE NO. 7

223. 5 1.5 10 1.5


224. LOAD COMB 210 1.5(DL+EQ(+X))
225. 5 1.5 1 1.5
226. LOAD COMB 211 1.5(DL+EQ(-X))
227. 5 1.5 2 1.5
228. LOAD COMB 212 1.5(DL+EQ(+Z))
229. 5 1.5 3 1.5
230. LOAD COMB 213 1.5(DL+EQ(-Z))
231. 5 1.5 4 1.5
232. LOAD COMB 214 0.9DL+1.5(WL+X(CP=-0.5))
233. 5 0.9 7 1.5
234. LOAD COMB 215 0.9DL+1.5(WL-X(CP=-0.5))
235. 5 0.9 8 1.5
236. LOAD COMB 216 0.9DL+1.5(WL+Z(CP=-0.5))
237. 5 0.9 9 1.5
238. LOAD COMB 217 0.9DL+1.5(WL-Z(CP=-0.5))
239. 5 0.9 10 1.5
240. LOAD COMB 222 0.9DL+1.5(EQ(+X))
241. 5 0.9 1 1.5
242. LOAD COMB 223 0.9DL+1.5(EQ(-X))
243. 5 0.9 2 1.5
244. LOAD COMB 224 0.9DL+1.5(EQ(+Z))
245. 5 0.9 3 1.5
246. LOAD COMB 225 0.9DL+1.5(EQ(-Z))
247. 5 0.9 4 1.5
248. LOAD COMB 226 1.2(DL+LL+WL+X(CP=-0.5))
249. 5 1.2 6 1.2 7 1.2
250. LOAD COMB 227 1.2(DL+LL+WL-X(CP=-0.5))
251. 5 1.2 6 1.2 8 1.2
252. LOAD COMB 228 1.2(DL+LL+WL+Z(CP=-0.5))
253. 5 1.2 6 1.2 9 1.2
254. LOAD COMB 229 1.2(DL+LL+WL-Z(CP=-0.5))
255. 5 1.2 6 1.2 10 1.2
256. LOAD COMB 234 1.2(DL+LL+EQ(+X))
257. 5 1.2 6 1.2 1 1.2
258. LOAD COMB 235 1.2(DL+LL+EQ(-X))
259. 5 1.2 6 1.2 2 1.2
260. LOAD COMB 236 1.2(DL+LL+EQ(+Z))
261. 5 1.2 6 1.2 3 1.2
262. LOAD COMB 237 1.2(DL+LL+EQ(-Z))
263. 5 1.2 6 1.2 4 1.2
264. LOAD COMB 238 1.5(DL+WL+X(CP=+0.5))
265. 5 1.5 11 1.5
266. LOAD COMB 239 1.5(DL+WL-X(CP=+0.5))
267. 5 1.5 12 1.5
268. LOAD COMB 240 1.5(DL+WL+Z(CP=+0.5))
269. 5 1.5 13 1.5

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

270. LOAD COMB 241 1.5(DL+WL-Z(CP=+0.5))


271. 5 1.5 14 1.5
272. LOAD COMB 242 0.9DL+1.5(WL+X(CP=+0.5))
273. 5 0.9 11 1.5
274. LOAD COMB 243 0.9DL+1.5(WL-X(CP=+0.5))
275. 5 0.9 12 1.5
276. LOAD COMB 244 0.9DL+1.5(WL+Z(CP=+0.5))
277. 5 0.9 13 1.5
278. LOAD COMB 245 0.9DL+1.5(WL-Z(CP=+0.5))

STAAD SPACE -- PAGE NO. 8

279. 5 0.9 14 1.5


280. LOAD COMB 246 1.2(DL+LL+WL+X(CP=+0.5))
281. 5 1.2 6 1.2 11 1.2
282. LOAD COMB 247 1.2(DL+LL+WL-X(CP=+0.5))
283. 5 1.2 6 1.2 12 1.2
284. LOAD COMB 248 1.2(DL+LL+WL+Z(CP=+0.5))
285. 5 1.2 6 1.2 13 1.2
286. LOAD COMB 249 1.2(DL+LL+WL-Z(CP=+0.5))
287. 5 1.2 6 1.2 14 1.2
288. ********************
289. PERFORM ANALYSIS

290. PARAMETER 1
291. CODE IS800 LSD
292. CHECK CODE ALL
STEEL DESIGN

|----------------------------------------------------------------------------------|
| Member Number: 1 |
| Member Section: ST 100X100X5.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.787 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 2 |
| Member Section: ST 100X100X5.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.787 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 3 |
| Member Section: ST 100X100X5.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.702 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

STAAD SPACE -- PAGE NO. 9

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 4 |
| Member Section: ST 100X100X5.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.702 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 5 |

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |


| Status: PASS Ratio: 0.531 Critical Load Case: 40 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 6 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.538 Critical Load Case: 40 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 7 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.877 Critical Load Case: 43 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

STAAD SPACE -- PAGE NO. 10

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 8 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.877 Critical Load Case: 43 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 9 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.529 Critical Load Case: 43 Location: 0.89 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 10 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.529 Critical Load Case: 43 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 11 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.898 Critical Load Case: 42 Location: 0.89 |
| Critical Condition: Sec. 8.2.1.2 |

STAAD SPACE -- PAGE NO. 11

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 12 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.529 Critical Load Case: 43 Location: 0.89 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 13 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

| Status: PASS Ratio: 0.529 Critical Load Case: 43 Location: 0.00 |


| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 14 |
| Member Section: ST 80X80X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.898 Critical Load Case: 42 Location: 0.89 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 15 |
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.624 Critical Load Case: 41 Location: 1.77 |
| Critical Condition: Sec. 8.2.1.2 |

STAAD SPACE -- PAGE NO. 12

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 16 |
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.685 Critical Load Case: 41 Location: 1.77 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 17 |
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.626 Critical Load Case: 41 Location: 1.77 |
| Critical Condition: Sec. 8.2.1.2 |

293. PARAMETER 2
294. CODE IS800 LSD
295. STEEL MEMBER TAKE OFF LIST ALL

STAAD SPACE -- PAGE NO. 13

STEEL TAKE OFF

STEEL TAKE-OFF
--------------

PROFILE LENGTH(METE) WEIGHT(KN )

ST 100X100X5.0SHS 12.65 1.784


ST 80X80X4.0SHS 14.19 1.281
ST 60X60X4.0SHS 10.62 0.698
----------------
TOTAL = 3.763

MEMBER PROFILE LENGTH WEIGHT


(METE) (KN )

1 ST 100X100X5.0SHS 3.33 0.469


2 ST 100X100X5.0SHS 3.33 0.469
3 ST 100X100X5.0SHS 3.00 0.423
4 ST 100X100X5.0SHS 3.00 0.423
5 ST 80X80X4.0SHS 3.54 0.320

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

6 ST 80X80X4.0SHS 3.54 0.320


7 ST 80X80X4.0SHS 0.89 0.080
8 ST 80X80X4.0SHS 0.89 0.080
9 ST 80X80X4.0SHS 0.89 0.080
10 ST 80X80X4.0SHS 0.89 0.080
11 ST 80X80X4.0SHS 0.89 0.080
12 ST 80X80X4.0SHS 0.89 0.080
13 ST 80X80X4.0SHS 0.89 0.080
14 ST 80X80X4.0SHS 0.89 0.080
15 ST 60X60X4.0SHS 3.54 0.233
16 ST 60X60X4.0SHS 3.54 0.233
17 ST 60X60X4.0SHS 3.54 0.233
----------------
TOTAL = 3.763

************ END OF DATA FROM INTERNAL STORAGE ************

296. FINISH

STAAD SPACE -- PAGE NO. 14

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= OCT 18,2023 TIME= 12:14:59 ****

************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2015 Bentley Systems, Inc.
* http://www.bentley.com *
************************************************************

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

5.2 SUPPORT REACTION

Horizontal Vertical Horizontal Moment


Node L/C Fx kN Fy kN Fz kN Mx kNm My kNm Mz kNm
Max Fx 3 215 12.049 -3.321 -0.309 -0.07 0.107 -11.493
Min Fx 1 214 -12.049 -3.321 -0.309 -0.07 -0.107 11.493
Max Fy 1 201 0.757 7.048 -1.087 -1.269 0.005 -0.836
Min Fy 5 242 -6.048 -13.009 5.091 1.582 -0.233 7.776
Max Fz 1 217 0.209 -3.754 12.047 11.555 -0.002 0.139
Min Fz 5 216 0.057 -3.185 -11.337 -10.307 -0.04 0.243
Max Mx 1 217 0.209 -3.754 12.047 11.555 -0.002 0.139
Min Mx 5 216 0.057 -3.185 -11.337 -10.307 -0.04 0.243
Max My 7 243 6.048 -13.009 5.091 1.582 0.233 -7.776
Min My 5 242 -6.048 -13.009 5.091 1.582 -0.233 7.776
Max Mz 1 214 -12.049 -3.321 -0.309 -0.07 -0.107 11.493
Min Mz 3 215 12.049 -3.321 -0.309 -0.07 0.107 -11.493

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

5.3 FOOTING DESIGN

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

ISSUE: R0
DESIGN REPORT FOR CONTROL ROOM

5.4 BASE PLATE DESIGN

ISSUE: R0
PART POSTIVE AND PART NEGATIVE PRESSURE OVER BASE PLATE

DESIGN OF BASE PLATE


1) Input parameters
moment = 11.56 KN-m
compression axial load = -3.75 KN
axial tension load = 0.00 KN
shear force (V) = 12.05 KN
Grade of concrete of pedestal (fck) = 25 N/mm2
Design compressive stress (fcd) = 11.25 N/mm2
Yield strength of steel (fy) = 250 N/mm2
Ultimate tensile strength of steel (fu) = 410 N/mm2
Partial safety of factor for resistance of section = 1.25
Partial safety of factor for resistance of section = 1.50
Partial factor of safety in yielding (Ymo) = 1.10
Bolt properties
Diameter of bolts = 16 mm
Hole diameter (Do) = 18 mm
Grade of bolts = 4.60 Grade
Ultimate tensile strength of bolt material (fub)min = 400 N/mm2
Yield strength of bolt material (fyb)min = 240 N/mm2
Pitch = 2.00
Bolt tension area (Threaded area) = 155.07 mm2
Nos. of bolts = 4 nos
Edge distance of the bolt along bearing distance (e) = 27.00 mm
Pitch of bolt = 40.00 mm
Section properties
Selected section = SHS100X100X5.0
Depth of section (d) = 100.00 mm
Lx = 100.00 mm
Width of section (bf) = 100.00 mm
Thickness of flange (tf) = 5.00 mm

2) Design of base plate


a) Dimension of base plate
Forces at flange centroid, due to moment
Left flange = 121.68 KN
Right flange = -121.68 KN
Total force
Total compression = 119.81 KN
Total tension = -123.56 KN

a = 85 mm
M+Na = 11.24 kn*m
0.5X0.45fckB(L/2+a)^2 = 295.31
L/2+a = 210.00 mm

y = 19.98 mm
0.45fckyB = 56.20 kn
Fb = 59.95 kn
Area of base plate required = 10649.71 mm2
For square base plate, provide L = B = 103.20 mm
Distance from flange to bolt for workability = 35.00 mm
Minimum size of plate = 224 mm
Provided L = 250.00 mm
Provided B = 250.00 mm
Larger projection of the base plate beyond the column (a) = 75.00 mm
Shorter projection of the base plate beyond the column (b) = 75.00 mm

b) Check for bearing pressure at concrete


Intensity of pressure (w) = 1.92 N/mm2
SAFE
c) Thickness of base plate
Minimum thickness of base plate (tmin) = tf = 5.00 mm
Thickness of base plate (t) = 9.11 mm
assumed thicness of plate = 20.00 mm

max bending moment = 3.65 knm


moment cap of base plate = 4.55 knm
SAFE
Provided thickness of base plate (tprov) = 20.00 mm

d) Size of weld
Provide nominal fillet weld of size (Leg length) = 5.00 mm
Throat size = leg length x cos45 = 3.50 mm
Design weld resistance per unit length = 0.78 KN/mm
Provided weld length = 400.00 mm
Weld strength = 311.60 KN
SAFE
3) Design of anchor bolts
a) Check for moment
Design tensile force on each bolt (Tb) = 29.98 KN
Design tensile capacity of bolt (Tdb) = 44.66 KN
SAFE
b) Check for shear
Design shear force on each bolt (Vsb) = 3.01 KN
Shear capacity of bolt = 29.77 KN
Bearing capacity of plate = 104.96 KN
Design shear capacity (Vdb) = 29.77 KN
SAFE
c) Check for combined shear and tension

= 0.46

SAFE
d) Embedment length
Bond stress for M25 grade concrete = 0.90 N/mm2
Length for embedment (Ld) = 51.97 mm
Length for embedment (Ld) = 662.64 mm
Adopt length for embedment (Ld) = 1000.00 mm

4) Summary
Base plate
Grade of steel = Fe250
Length = 250 mm
Width = 250 mm
Thickness of plate = 20 mm
Size of weld = 5 mm
Anchor bolts
Size of bolt = 16
Grade of bolts = 4.60
4 nos. of 16mm anchor bolts embedded 1000 mm in to the concrete
POSTIVE PRESSURE OVER FULL BASE PLATE

DESIGN OF BASE PLATE


1) Input parameters
moment = 1.27 KN-m
compression axial load = 7.05 KN
axial tension load = 0.00 KN
shear force (V) = 1.09 KN
Grade of concrete of pedestal (fck) = 25 N/mm2
Design compressive stress (fcd) = 11.25 N/mm2
Yield strength of steel (fy) = 250 N/mm2
Ultimate tensile strength of steel (fu) = 410 N/mm2
Partial safety of factor for resistance of section = 1.25
Partial safety of factor for resistance of section = 1.50
Partial factor of safety in yielding (Ymo) = 1.10
Bolt properties
Diameter of bolts = 16 mm
Hole diameter (Do) = 18 mm
Grade of bolts = 4.60 Grade
Ultimate tensile strength of bolt material (fub)min = 400 N/mm2
Yield strength of bolt material (fyb)min = 240 N/mm2
Pitch = 2.00
Bolt tension area (Threaded area) = 155.07 mm2
Nos. of bolts = 4 nos
Edge distance of the bolt along bearing distance (e) = 27.00 mm
Pitch of bolt = 40.00 mm
Section properties
Selected section = SHS100X100X5.0
Depth of section (d) = 100.00 mm
Lx = 100.00 mm
Width of section (bf) = 100.00 mm
Thickness of flange (tf) = 5.00 mm

2) Design of base plate


a) Dimension of base plate
Forces at flange centroid, due to moment
Left flange = 13.37 KN
Right flange = -13.37 KN
Total force
Total compression = 16.89 KN
Total tension = -9.84 KN

Area of base plate required = 1501.64 mm2


For square base plate, provide L = B = 38.75 mm
Distance from flange to bolt for workability = 35.00 mm
Minimum size of plate = 224 mm
Provided L = 250.00 mm
Provided B = 250.00 mm
Larger projection of the base plate beyond the column (a) = 75.00 mm
Shorter projection of the base plate beyond the column (b) = 75.00 mm

b) Check for bearing pressure at concrete


Intensity of pressure (w) = 0.27 N/mm2
SAFE
c) Thickness of base plate
Minimum thickness of base plate (tmin) = tf = 5.00 mm
Thickness of base plate (t) = 3.42 mm

Provided thickness of base plate (tprov) = 20.00 mm

d) Size of weld
Provide nominal fillet weld of size (Leg length) = 5.00 mm
Throat size = leg length x cos45 = 3.50 mm
Design weld resistance per unit length = 0.78 KN/mm
Provided weld length = 400.00 mm
Weld strength = 311.60 KN
SAFE
3) Design of anchor bolts
a) Check for moment
Design tensile force on each bolt (Tb) = 4.92 KN
Design tensile capacity of bolt (Tdb) = 44.66 KN
SAFE
b) Check for shear
Design shear force on each bolt (Vsb) = 0.27 KN
Shear capacity of bolt = 29.77 KN
Bearing capacity of plate = 104.96 KN
Design shear capacity (Vdb) = 29.77 KN
SAFE
c) Check for combined shear and tension

= 0.01

SAFE
d) Embedment length
Bond stress for M25 grade concrete = 0.90 N/mm2
Length for embedment (Ld) = 51.97 mm
Length for embedment (Ld) = 108.79 mm
Adopt length for embedment (Ld) = 1000.00 mm

4) Summary
Base plate
Grade of steel = Fe250
Length = 250 mm
Width = 250 mm
Thickness of plate = 20 mm
Size of weld = 5 mm
Anchor bolts
Size of bolt = 16
Grade of bolts = 4.60
4 nos. of 16mm anchor bolts embedded 1000 mm in to the concrete
NEGATIVE PRESURE OVER FULL BASE PLATE

DESIGN OF BASE PLATE


1) Input parameters
moment = 7.77 KN-m
compression axial load = -13.00 KN
axial tension load = 0.00 KN
shear force (V) = 6.00 KN
Grade of concrete of pedestal (fck) = 25 N/mm2
Design compressive stress (fcd) = 11.25 N/mm2
Yield strength of steel (fy) = 250 N/mm2
Ultimate tensile strength of steel (fu) = 410 N/mm2
Partial safety of factor for resistance of section = 1.25
Partial safety of factor for resistance of section = 1.50
Partial factor of safety in yielding (Ymo) = 1.10
Bolt properties
Diameter of bolts = 16 mm
Hole diameter (Do) = 18 mm
Grade of bolts = 4.60 Grade
Ultimate tensile strength of bolt material (fub)min = 400 N/mm2
Yield strength of bolt material (fyb)min = 240 N/mm2
Pitch = 2.00
Bolt tension area (Threaded area) = 155.07 mm2
Nos. of bolts = 4 nos
Edge distance of the bolt along bearing distance (e) = 27.00 mm
Pitch of bolt = 40.00 mm
Section properties
Selected section = SHS100X100X5.0
Depth of section (d) = 100.00 mm
Lx = 100.00 mm
Width of section (bf) = 100.00 mm
Thickness of flange (tf) = 5.00 mm

2) Design of base plate


a) Dimension of base plate
Forces at flange centroid, due to moment
Left flange = 81.79 KN
Right flange = -81.79 KN
Total force
Total compression = 75.29 KN
Total tension = -88.29 KN

Area of base plate required = 6692.40 mm2


For square base plate, provide L = B = 81.81 mm
Distance from flange to bolt for workability = 35.00 mm
Minimum size of plate = 224 mm
Provided L = 250.00 mm
Provided B = 250.00 mm
Larger projection of the base plate beyond the column (a) = 75.00 mm
Shorter projection of the base plate beyond the column (b) = 75.00 mm

b) Check for bearing pressure at concrete


Intensity of pressure (w) = 1.20 N/mm2
SAFE
c) Thickness of base plate
Minimum thickness of base plate (tmin) = tf = 5.00 mm
Thickness of base plate (t) = 7.22 mm

Provided thickness of base plate (tprov) = 20.00 mm

d) Size of weld
Provide nominal fillet weld of size (Leg length) = 5.00 mm
Throat size = leg length x cos45 = 3.50 mm
Design weld resistance per unit length = 0.78 KN/mm
Provided weld length = 400.00 mm
Weld strength = 311.60 KN
SAFE
3) Design of anchor bolts
a) Check for moment
Design tensile force on each bolt (Tb) = 44.14 KN
Design tensile capacity of bolt (Tdb) = 44.66 KN
SAFE
b) Check for shear
Design shear force on each bolt (Vsb) = 1.50 KN
Shear capacity of bolt = 29.77 KN
Bearing capacity of plate = 104.96 KN
Design shear capacity (Vdb) = 29.77 KN
SAFE
c) Check for combined shear and tension

= 0.98

SAFE
d) Embedment length
Bond stress for M25 grade concrete = 0.90 N/mm2
Length for embedment (Ld) = 51.97 mm
Length for embedment (Ld) = 975.81 mm
Adopt length for embedment (Ld) = 1000.00 mm

4) Summary
Base plate
Grade of steel = Fe250
Length = 250 mm
Width = 250 mm
Thickness of plate = 20 mm
Size of weld = 5 mm
Anchor bolts
Size of bolt = 16
Grade of bolts = 4.60
4 nos. of 16mm anchor bolts embedded 1000 mm in to the concrete