Detail of reinforcement of 5x6 m minor bridge

8700.0000

h h
c 3000.0000
c
f f f f
2000.0000

5000.0000

a a a a
g 9600.00
g
b b

2300.0000 200.00

c+d f+c f+h f+h f+c c

b a+b a a a+a a a a+a a a a+a a a a+b b


c+d
D

d e
5800.0000 5800.0000
d e e e e e e e e e e d e d

g
c+d b' a'+b' a' a' a'+a' a' a' a'+a' a' a' a'+a' a' a' a'+b' b'

2300.0000 c+d f+c f+h f+h f+c

100.0000

g b' a' a' a' b' g


100.0000
9600.00
a'
1550.0000

c f f
h f f h c

k Reinforcement of Box Culvert Schedule of reinforcement

S.No. Type Dia. Spacing Length No.


i
.

1 a 16 200 9600 4x43


i NOTES: 2 b 16 200 5000 2x42
c
.

3 16 200 10700 4x43


1. All dim. are in mm and only written dim. to be followed
j
4 d 16 200 10400 2x42
2. M-20 grade concrete & s-415 HYSD bars are used. 5 e 16 200 6200 10x43
j 3. Clear cover of 25 mm over reinforcement in normal 6 f 20 200 3000 4x43
condition and 50 mm in surface in contact with earth and 7 g 10 300 1750 20x28
water. 8 h 16 200 9000 4x28
4. The design is safe upto 8 t/Sq.m. bearing capacity of the
9 a' 16 240 9600 4x36
soil.
10 b' 16 240 5000 2x35
11 f' 16 200 3000 4x42
5. Properly braced steel shutering may be used. 12 D 10 300 8300 621
13 i 20 300 Var. 3950 to 1000
Reinforcement of wing wall 14 j 20 300 Var. 2500 to 1000
15 k 10 200 Var.1000 to 4500
16 l 10 300 Var. 3950 to 1000