PIPE SYSTEMS ABN INSTAL CT FASER RD RECYCLING

Pipe system for recycled and reclaimed water


///
APPLICATION FIELDS STANDARDS

•UNE EN 15874: Supply systems made with plastic


•Recycling water materials for cold and hot water installations.
•Reclaimed water Polypropylene (PP).

•Rainwater applications •DIN 8077: Polypropylene pipes. Dimensions.


•Industry processes •DIN 8078: Polypropylene pipes. General requirements
for quality and trials.
ABN//INSTAL DIFFERENTIATING FEATURES
•RP 01.00: Special regulation for the brand AENOR for
plastic materials. Common requirements.
CT FASER RD •RP 01.58: Special regulation for the compliance Aenor
RECYCLING was •Classification of fireproof B,s1-d0. certification for the supply of cold and hot water
systems, made with plastic materials. High
• free of halogen.
exclusively • resistance of disinfection processes,
temperature resistant polypropylene ramdon pipes
(PP-RCT) and fittings of polypropylene (PP-R).
develop water • antimicrobial protection, •RP 01.78: Special regulation for the compliance
recycling. • anti-expansion micro-fibres,
AENOR certification for the supply systems in
polypropylene random with modified crystalline (PP-
• UV protection, RCT) and fiberglass (FV) for the installations in the
indoor of buildings for hot and cold water.
• anti-incrustation protection,
•RD 140/2003, which establishes the health criteria of
• impact resistance,
the quality of water for human consumption
• environmentaly friendly.
•Certification of compliance AENOR

Text for tenders


PP RCT FASER RP POLYPROPYLENE PIPE FOR WATER RECYCLING
ABN//INSTAL CT FASER RD RECYCLING, B, s1-d0 classification of fireproof and halogen free, made of PPR
CT RP multilayer, for recycling and reclaimed installations. Series ----, SDR ----, external diameter --- mm
and thickness --- mm. White internal layer RAL 9003 and silver external layer RAL 9006 with lilac stripes
PANTONE 2037-C, installed in accordance to current regulations.

100% RECYCLABLE ECOLOGICAL RECYCLED WATER B-s1,d0


HF UV
HALOGEN FREE PROTECTIÓN UV
RESISTANCE TO
DESINFECTION
100%EFICAZ CONTRA
LA LEGIONELLA

1.PPR CT RP grey external layer RAL 9006 with lilac strips


1 PANTONE 2037C, UV resistant.
2 The additives with antioxidants that are used for the external layer
3 minimized the degradation of sun exposure.
,d 0
- s 1 2.PP R CT RP grey middle layer RAL 7042 with micro-fibre anti-
B ABN
expansion.
Ensures high mechanical strength resistance and impact resistance
INSTAL
CT FAS with a less thick wall of the pipe, allowing the installation of lesser
ER RD R
ECYCLIN diameters in comparison to traditional PP R.
G
3. White internal layer RAL 9003 with additive resistant to the
disinfection, anti-incrustation and anti-microbial.
With a high resistance to disinfection processes, anti-microbial
protection, anti-incrustation, also provides 100% protection against
the legionella.

ABN//INSTAL CT FASER RD RECYCLING //////////////////////////////////////// TECHNICAL SHEET


June 2019
///////////////////////////////// TECHNICAL DATA 50 years operating pressures in accordance to
DIN 8077
Material PPR CT RP + FV (SF:1,25)

Density 905 kg/m3 according to ISO 1183


Serie 20ºC 60ºC 70ºC 80ºC*
3.2 31.7 17.7 14.9 12.7
Melt-flow rate 0,30 g/10 min according to ISO 1133
5 20.3 11.3 9.5 8.1
Coefficient of
linear thermal expansion 0,04 mm/m ºC Serie 10ºC 20ºC 50ºC 70ºC
Modulus of elasticity 900 Mpa according to ISO 527 8 14.6 12.7 8.3 6.0
Thermal conduction
coefficient 0.24 w/mk according to DIN 52612 *For this temperature 25 years
Production EN ISO 15874/DIN 8077/DIN 8078

REACTION-TO-FIRE
ACCORDING TO THE EUROPEAN STANDARD EN 13501

PRODUCT RANGE
Classes A to F
CODE DIAMETER THICKNESS Series/ LENGHT
(mm) (mm) SDR (m) A1, A2 = Non combustible materials (only metallic and inert material)
B = Hardly combustible materials
D0CTFR3202000 20 2.8 3,2/7.4 4,0 C, D = Combustible materials
D0CTFR3202500 25 3.5 3.2/7.4 4,0 E = Easily combustible materials
D0CTFR3203200 32 4.4 3.2/7.4 4,0 F = Materials not submitted to the test of reaction to fire

D0CTFR5004000 40 3.7 5/11 4,0 Classes S1 to S3


D0CTFR5005000 50 4.6 5/11 4,0
D0CTFR5006300 63 5.8 5/11 4,0 S1 = Low smoke emission
S2 = Normal smoke emission
D0CTFR8007500 75 4.5 8/17 4,0 S3 = High smoke density
D0CTFR8009000 90 5.4 8/17 4,0
D0CTFR8011000 110 6.6 8/17 4,0 Classes d0 to d2
D0CTFR8012500 125 7.4 8/17 5,8
D0CTFR8016000 160 9.5 8/17 5,8 d0 = no droplets
d1 = droplets that extinguish within 10 s
d2 = droplets during the small flame test

ABN//INSTAL CT FASER RD RECYCLING


reaction-to-fire classification
Hardly combustible Scarce smoke No dripping
materials emission

B - s 1 , d 0

Member of:
Distributor
TUB
Grupo Sectorial Tuberías Plásticas de

Manufactured
HEAD OFFICES PRODUCTION SITE in
Spain

ESTRADA BAÑOS DE ARTEIXO, 28 PARQUE EMPRESARIAL MEDINA ON


PARQUE EMPRESARIAL AGRELA AUTOVÍA A-6, KM 152
15008 A CORUÑA (SPAIN) 47400 MEDINA DEL CAMPO
PIPE SYSTEMS VALLADOLID (SPAIN)
T. +34 902 202 532 Válido hasta el 31 de diciembre de 2018

F. +34 902 253 240 INFO@GRUPOABN.COM