KL2334a
LIST OF PARAMETERS
CONNECTION DIAGRAM
TIMING DIAGRAMS
CONTENTS Page
4 Setting and Putting into Service with the Aid of the Fast Installation Routine (SIR) 8
7 List of Parameters 58
7.1 Preset Values Depending on Mode 58
7.2 Operator Level 60
7.3 Technician Level 62
7.4 Supplier Level 68
8 Error Displays 81
The FP220A control (socket B18) and the computer (socket com1) are connected by means of interface IF232-2.
Set of special C200 compiler accessories consisting of: order no. 1113262
! C200 Compiler Software CD-ROM
! C200 Compiler User Manual
! EFKANET IF232-2 Interface
See C200 Compiler user manual for more information on programming and use of control commands!
EFKA FP220A5900 6
Explanation of letter symbols of the previous page and chapter ”Timing Diagrams“
Outputs:
! The correct installation of the drive, position transmitter and accompanying devices, if necessary
! If necessary, the correct adjustment of the direction of motor rotation by means of parameter 161
! The correct selection of the functions of keys (inputs) by means of parameters 240...249
! The setting of the transmission ratio between motor shaft and machine shaft by means of parameter 272
! If necessary, the setting of the number of angular degrees after the sensor position by means of parameter 271
! The correct maximum speed compatible with the sewing machine by means of parameter 111
4 Setting and Putting into Service with the Aid of the Fast Installation
Routine (SIR)
The Fast Installation Routine (SIR) passes through all parameters necessary for programming the functional sequence and
the positions.
Code 3112
E
F-200
Yes
E
No
P
The values can be varied by pressing the +/- keys. When the parameter is displayed on the V810 control panel, press
the E key once more for the value to be displayed.
Exit the routine any time by pressing the P key once, and select a new parameter. Exit programming by pressing the P key
twice, and the drive is ready for a new sewing operation.
S1 P key
! Call or exit programming mode
S2 E key
! Start backtack single / double / off
! Enter key for modifications in the programming mode
S3 + key
! End backtack single / double / off
! Increase of the value indicated in the programming mode
S4 – key
! Automatic sewing foot lifting at stop in the seam On/Off
! Automatic sewing foot lifting after thread trimming
On/Off 0
! Decrease of the value indicated in the programming mode
S5 >> key I
! Basic position 1 or 2
! Shift key in the programming mode
Display 3 digits
FP220A5900
KL2470
EFKA FP220A5900 10
B2 B80
M
B80 Socket for actuator
B2 EB...
B80
B18 B776
B776 Socket for V810/V820 control panel
B18 B776
LSM... V8 . .
ST2
ST2
KL2333
11 EFKA FP220A5900
SetOut 7: *)
SetOut 8: *)
SetOut 9: *)
SetOut 3: *)
SetOut 2: *)
SetOut 10: *)
SetOut 6: *)
SetOut 11: *)
SetOut 7: *)
SetOut 13: *)
SetOut 12: *)
SetOut 4: *)
SetOut 1: *)
ATTENTION!
When connecting the outputs, ensure that a total power of 96VA constant load will not
be exceeded!
SetOut 7: *)
SetOut 8: *)
SetOut 9: *)
SetOut 3: *)
SetOut 2: *)
SetOut 10: *)
SetOut 6: *)
SetOut 11: *)
SetOut 7: *)
SetOut 13: *)
SetOut 12: *)
SetOut 4: *)
SetOut 1: *)
ATTENTION!
When connecting the outputs, ensure that a total power of 96VA constant load will not
be exceeded!
1) Nominal voltage 24V, no-load voltage max. 30V momentarily after power on
2) Transistor output with open collector max. 40V, 10mA
3) Nominal voltage 15V, Imax = 30mA
4) Nominal voltage 5V, Imax = 20mA
*) Front view of the socket (component side) and/or rear view of the plug (soldering side)
13 EFKA FP220A5900
If parameter 239 is set to 1...42, a key can be operated on the input of socket B18/8.
B80
B2 J4 J4
J4
1 3 1 3
2 4 2 4
KL2351
ATTENTION!
Before opening the cover, turn power off!
EB.. Actuator
ATTENTION!
Before opening the cover, turn power off!
! Switch off the control and remove mains plug from outlet A
! Unscrew the control unit from the machine table
! Loosen 4 screws (A)
! Remove the mounting plate C
! Loosen 2 screws (B) each at the front and at the rear
! Open the left part of the housing
! Pull the sewing light cable through the cable bushing
!
0
Area (C): Connect strands with clamp on the printed circuit board
B I
! Insert earth lead into plug-in device on the housing part
! Close and screw-connect the housing
! Mount the control unit on the machine table
P
>>
KL2399
CAUTION!
When the sewing light is connected, it is always current-carrying (230V), even if
the control unit is switched off! Only one sewing light with transformer can be
connected to the control unit!
15 EFKA FP220A5900
9
B41 B5 B5
B41 M M M
8
B5 B5
mot 1 mot 1
7
B2 B80 B776 B776
6
B2 EB...
B80 B776 V8 . .
B776 V8 . .
5
B18 B776 B18 B19 B18 B19
B18 B776
4
B18 B19 B18 B19
LSM... V8 . .
control LSM... control LSM...
Br.
3
Nr. 1113172 Nr. 1113172
2
ST2
ST1 ST1
ST2
1
ST1 ST1
5 1
SUB-D-9
(*)
KL2484
9 6
! Parameter 272 = 2 #2 = SCI stepping motor control address. All additional controls have higher addresses
(..#3, #4, etc.)
ATTENTION
Turn on the FP220A / FP320A control together with the connected SM210A controls
by means of one mains switch.
Place a jumper between pin 2 and pin 3 on socket B19 of the last SM210A stepping
motor control.
Set the baud rate of parameter 162 = - - - - - in order to download data from the PC
into the FP220A / FP320A control.
Then reset the baud rate to 560 for stepping motor operation.
EFKA FP220A5900 16
Setting the functional sequence Thread trimming mode " Set parameter 290 = 0
Setting the functions of the keys Input in1 " Set parameter 240 = 16
Input in3 " Set parameter 242 = 1
Nr. 1112815 1
1
1 2
2
ST2 +24V 3
3
4 0V FL 4
4
6 in3
7 in1 NHT 1
1 1
20 0V 2
2
16 +24V FA1+2 3
3
17 +24V +24V 4
4
SUB-D-37
18 +24V
19 0V
ZVR 1
1
26 +24V 0V 2
2
27 M3 +24V 3
3
28 M2 VR 4
19 37 4
34 VR
35 FL FW 1
1
2
2
37 M1 +24V 3
3
KL2234
Setting the functional sequence Thread trimming mode " Set parameter 290 = 0
Setting the functions of the keys Input in1 " Set parameter 240 = 16
Input in3 " Set parameter 242 = 1
1 Nr. 1112814 1
ST2 2
4 0V 3
FA1+2 4 3 2 1
6 in3 + 24V 5
7 in1 6 5
1 6 4
20 FW 7 8
9 7
16 +24V + 24V 8
17 +24V ZVR 9
12 11 10
SUB-D-37
18 +24V VR 10
19 0V + 24V 11
0V 12
26 +24V
27 M3
28 M2 + 24V 1
19 37
2
6 3
34 VR NHT 3
5 2
35 FL FL 4
4 1
0V 5
37 M1 6
KL2233
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
17 EFKA FP220A5900
Setting the functional sequence Thread trimming mode " Set parameter 290 = 5
Setting the functions of the keys Input in1 " Set parameter 240 = 7
Input in3 " Set parameter 242 = 18
Input in4 " Set parameter 243 = 16
Input in5 " Set parameter 244 = 17
Nr. 1112822
1 LSP 1
0V 3
4 0V +5V 4 1
4 6
5 in5 ENTK 5
6 in3 STVU 6 2
1 20 7 in1 FW 7 5 7
8 in4 3
SUB-D-37
+24V 1
STV 2
16 +24V 3
17 +24V +24V 4 3 2 1
18 +24V FA 5
19 0V 0V 6 5
19 37 6 4
+24V 7 8
9 7
26 +24V FA 8
27 M3 9
12 11 10
28 M2 10
11
LSP 12
34 VR
35 FL
+24V 1
37 M1 2
6 3
3
5 2
FL 4
4 1
5
6
KL2241
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
EFKA FP220A5900 18
Setting the functional sequence Thread trimming mode " Set parameter 290 = 0
Setting the functions of the keys Input in1 " Set parameter 240 = 16
Input in3 " Set parameter 242 = 1
Input in4 " Set parameter 243 = 3
Input in5 " Set parameter 244 = 17
Nr. 1112845
1 1
ST2 2
4 0V FW 3
5 in5 4
6 in3 0V 5 9
7 in1 POS1 6 8
10
1 20 7
8 in4 +24V 7 1
6
FA1+2 8 5
2
16 +24V VR 9 4
SUB-D-37
3
FL 10
18 +24V
19 0V
20 POS1 NHT 1
1 6
0V 2 4
27 M3 VRU 3
19 37 2
28 M2 4
5 7
ZVR 5 3
34 VR EST 6
35 FL 7
37 M1
KL2259a
Setting the functional sequence Thread trimming mode " Set parameter 290 = 5
Setting the functions of the keys Input in1 " Set parameter 240 = 6
Nr. 1112866
1 FA 1
ST2 2
4 0V + 24V 3
4 3 2 1
7 in1 5
6 5
1 6 4
20 FL 7 8
9 7
17 +24V 8
18 +24V + 24V 9
12 11 10
SUB-D-37
0V 10
11
27 M3 LSP 12
35 FL
19 37
37
KL2301
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
19 EFKA FP220A5900
Setting the functional sequence Thread trimming mode " Set parameter 290 = 14
Setting the functions of the keys Input in1 " Set parameter 240 = 16
Nr. 1112816
1 ZVR 1
ST2 0V 2
4 0V 3
4 3 2 1
5
11 in2 +24V 6 5
1 6 4
20 +24V 7 8
9 7
16 +24V VR 8
17 +24V FW 9
12 11 10
SUB-D-37
18 +24V +24V 10
FA1+2 11
26 +24V 12
27 M3
FL 1
19 37 1
34 VR +24V 2
2
35 FL
37 M1
KL2235b
Setting the functional sequence Thread trimming mode " Set parameter 290 = 14
Setting the functions of the keys Input in1 " Set parameter 240 = 16
Nr. 1113132
1 FA1+2 1
ST2 FW 2
3
11 in2 FZ 4
ZVR 5
16 +24V VR 6 7 14
1 20 17 +24V 7 6 13
5 12
18 +24V +24V 8
4 11
19 0V +24V 9
3 10
SUB-D-37
10 2 9
26 +24V +24V 11 1 8
27 M3 0V 12
28 M2 +24V 13
14
33 +24V
19 37
34 VR
35 FL FL 1 1 2
+24V 2
37 M1
KL2363
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
Setting the functional sequence Thread trimming mode " Set parameter 290 = 20
Setting the functions of the keys Input in1 " Set parameter 240 = 13
(Automatic setting) Input in3 " Set parameter 242 = 31
Input in4 " Set parameter 243 = 32
Input in6 " Set parameter 245 = 16
Input in7 " Set parameter 246 = 13
Nr. 1113200
1 FA 1
ST2 2
4 0V 3
4
6 in3 ZVR 5
VR 6 7 14
1 20 8 in4 +24V 7 6 13
5 12
9 in7 +24V 8
4 11
9
3 10
SUB-D-37
12 in6 10 2 9
11 1 8
16 +24V 0V 12
17 +24V +24V 13
18 +24V FSPL 14
19 0V
19 37
26 +24V 0V 1
S1 2
28 M2 HP out 3
4 3 2 1
30 M6 S2 5
HP in 6 5
6 4
33 +24V 7 8
9 7
34 VR +24V 8 11
12 10
35 FL 9
0V 10 15 13
37 M1 14
15
FL 1 1 2
+24V 2
KL2437
in1 = Input high lift for walking foot with speed limitation n10 (operational mode not stored) for knee switch
in3 = Input speed limitation bit 0 (S1)
in4 = Input speed limitation bit 1 (S2)
in6 = Input intermediate backtack
in7 = Input high lift for walking foot with speed limitation n10 (operational mode not stored) for additional
pushbutton at the machine head
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
Setting the functional sequence Thread trimming mode " Set parameter 290 = 5
Setting the functions of the keys Input in1 " Set parameter 240 = 7
1 20 7 in1
+24V 1
16 +24V FA 2
SUB-D-37
6 3
17 +24V +24V 3
5 2
18 +24V FW 4
4 1
+24V 5
26 +24V ML 6
27 M3
19 37
32 M5 1
1
35 FL 2
2
+24V 3
3
37 M1 FL 4
4
KL2362
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
EFKA FP220A5900 22
Adapter cord for PFAFF models 563, 953, 1050, 1180 without thread monitor
Setting the functional sequence Thread trimming mode " Set parameter 290 = 0
Setting the functions of the keys Input in4 " Set parameter 243 = 12
Input in5 " Set parameter 244 = 16
ST2 FLEX 3
4 0V VR 4
5 in5 FL 5
5
6
+24V 6
4
8 in4 1
1 20
2 3
16 +24V FA1 1
17 +24V +24V 2
SUB-D-37
18 +24V +24V 3 2 1
19 0V FA2 4
3 6
FW 5
26 +24V 0V 6 4 5
27 M3
28 M2
19 37
FA1 1
32 M5 +24V 2
+24V 3 2 1
34 VR FA2 4
3 6
35 FL FW 5
ML 6 4 5
37 M1
VR 1 2 1
+24V 2
ZVR 3
3 4
0V 4
VR 1 2 1
+24V 2
ZVR 3
3 4
0V 4
KL2261
*) Rear view (soldering side) of 37-pin plug (ST2) and of the remaining sockets.
23 EFKA FP220A5900
Adapter cord for PEGASUS models W500/UT, W600/UT/MS with or without stitch condensing
Setting the functional sequence Thread trimming mode " Set parameter 290 = 5
Setting the functions of the keys Input in1 " Set parameter 240 = 7
Nr. 1112821
1 FA 1
26 +24V +5V 1
1
27 M3 LSP 2
2
28 M2 0V 3
19 37
33 +24V +24V 1
1
34 VR FL 2
2
35 FL
37 M1 STV 1
1
+24V 2
2
KL2240
Attention! When using this adapter cord on a Pegasus machine, the 9-core cable no. 742373-91 must be
removed from the machine!
Setting the functional sequence Thread trimming mode " Set parameter 290 = 8
Setting the functions of the keys Input in1 " Set parameter 240 = 6
(Automatic setting) Input in3 " Set parameter 242 = 10
Nr. 1113234
1 1
ST2 Ped=1 2
Ped=-1 3
4 1
4 0V 4
5 2
5
6 3
N-AUTO 6
1 20 6 in3
7 in1
0V 1
SUB-D-37
LSP 2
6 3
19 0V 3
5 2
4
4 1
0V 5
6
28 M2
19 37
Ped=-1 1
1
37 M1 0V 2
2
KL2458
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
EFKA FP220A5900 24
Setting the functional sequence Thread trimming mode " Set parameter 290 = 24
Setting the functions of the keys Input in1 " Set parameter 240 = 6
Input in2 " Set parameter 241 = 13
Input in3 " Set parameter 242 = 28
Input in4 " Set parameter 243 = 22
1 Nr.1113267
in4 1
2 +5V 0V 2
1
ST2 2
4 0V
0V 1
6 in3 SEN 2 1
7 in1 +15V 3 2
1 20 8 in4 3
11 in2 FA 1
SUB-D-37
+24V 2
15 +15V FA 3
16 +24V +24V 4 3 2 1
17 +24V FW 5
5
18 +24V +24V 6 6 4
19 0V 7
19 37
8 9 8 7
23 M7 9
25 M9
26 +24V +5V 1
1
27 M3 LSP 2
2
28 M2 0V 3
3
32 M5
33 +24V +24V 1
1
FL 2
2
35 FL
37 M1 M5 1
1
+24V 2
2
+24V 1
M7 2
4 1
+24V 3
5 2
M9 4
6 3
in2 5
0V 6
KL2482
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
25 EFKA FP220A5900
Setting the functional sequence Thread trimming mode " Set parameter 290 = 5
Nr. 1113096
ST2 1
16 +24V
1 20 17 +24V FW 1
18 +24V ML 2
FAO 3
SUB-D-37
27 M3 FAU 4 2 1
28 M2 FL 5
3 6
+24V 6
32 M5 4 5
35 FL
19 37
37 M1
KL2346
Setting the functional sequence Thread trimming mode " Set parameter 290 = 2
(Singer model 212UTT)
Setting the functions of the keys Input in1 " Set parameter 240 = 1
Input in3 " Set parameter 242 = 16
Nr. 1112824
1 +24V 1
ST2 FW/FSPL 2
4 0V NHT 3
6 3
0V 4
5 2
6 in3 ZVR 5
4 1
7 in1 0V 6
1 20
16 +24V
17 +24V +24V 1
1
SUB-D-37
18 +24V VR 2
2
19 0V +24V 3
3
FA2/FA 4
4
26
27 M3
28 M2 FL 1
19 37 1
0V 2
2
33 +24V +24V 3
3
34 VR FL 1 4
4
35 FL
36 M4
37
KL2243
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
EFKA FP220A5900 26
Setting the functional sequence Thread trimming mode " Set parameter 290 = 4
Setting the functions of the keys Input in1 " Set parameter 240 = 6
Input in3 " Set parameter 242 = 6
Nr. 1112905
1 +24V 1 1
2
ST2 POS1 2
4 0V LSP 3
0V 4 3 4
6 in3
7 in1
1 20 +24V 1
15 +15V 2 5
6
16 +24V ML 3
4
SUB-D-37
1
4
19 0V FL 5 2 3
20 POS1 6
26 +24V
27 M3 +24V 1
19 37
28 M2 FA-V 2
FW 3 9
32 M5 0V 4 8
10
7
33 +24V +15V 5 1
6
34 VR LSP 6 5
2
35 FL 7 4
3
8
37 M1 9
FA-R 10
KL2306
in1 = Input machine run blockage for thread trimming control proximity switch
in3 = Input machine run blockage for thread monitor
Setting the functional sequence Thread trimming mode " Set parameter 290 = 10
Nr. 1112823
1 1
ST2 ML 2
+24V 3
16 +24V FL 4 9
17 +24V FA-V 5 8
10
7
6 1
1 6
20 19 0V 7 5
2
FW 8 4
3
27 M3 9
SUB-D-37
28 M2 FA-R 10
32 M5
1 2 1
34 VR 2
35 FL 3
19 37
3 4
0V 4
37
KL2242
*) Rear view (soldering side) of 37-pin plug (ST2) and of the remaining sockets.
27 EFKA FP220A5900
Adapter cord for UNION SPECIAL model 34700 with stitch lock
Setting the functional sequence Thread trimming mode " Set parameter 290 = 5
Setting the functions of the keys Input in8 " Set parameter 247 = 7
Input in9 " Set parameter 248 = 6
ST2 FW 3
4 0V 0V 4 9
+15V 5 8
10
7
10 in8 LSP 6 1
6
7 5
1 20 2
13 in9 NK 8 4
3
9
15 +15V FA 10
SUB-D-37
16 +24V
17 +24V
18 +24V
19 0V
20 POS1
19 37
26 +24V
1
27 M3 +24V 1
28 M2 2
2
STV 3
32 M5 3
33 +24V
34 VR
35 FL +24V 1
2 1
POS1 2
37 M1 STOP 3
0V 4 3 4
+24V 1
2
5
6
ML 3
4
4 1
FL 5 2 3
6
KL2260
*) Rear view (soldering side) of 37-pin plug (ST2) and of the remaining sockets.
EFKA FP220A5900 28
Setting the functional sequence Thread trimming mode " Set parameter 290 = 4
Setting the functions of the keys Input in1 " Set parameter 240 = 6
Input in3 " Set parameter 242 = 6
Input in4 " Set parameter 243 = 18
Input in5 " Set parameter 244 = 12
Nr. 1112865 0V 1
FLAT-S 2
FLEX 3 1
1
2
ST2
4 0V 0V 1
3
5 in5 FLAT-S 2
6 in3 FLEX 3
7 in1
1 20 8 in4
+24V 1 1
2
15 +15V POS1 2
SUB-D-37
16 +24V LSP 3
17 +24V 0V 4 3 4
19 0V
20 POS1 +24V 1
21 POS2 GEN 2
19 37
22 GEN 3 1
4 6
ML 4
26 +24V FL 5 2 8
27 M3 POS2 6 5 7
3
28 M2 POS1 7
0V 8
32 M5
33 +24V
34 VR +24V 1
35 FL FW 2 5
6
ML 3 4
1
37 4
FL 5 2 3
FA-V 6
+24V 1
FA-V 2
FW 3 9
0V 4 8
10
7
+15V 5 1
6
LSP 6 5
2
7 4
3
8
9
FA-R 10
KL2289
in1 = Input machine run blockage for thread trimming control proximity switch
in3 = Input machine run blockage for thread monitor
in4 = Input unlocking the chain corresponds to function flatseamer (FLAT-S)
*) Rear view (soldering side) of 37-pin plug (ST2) and of the remaining sockets.
29 EFKA FP220A5900
Setting the functional sequence Thread trimming mode " Set parameter 290 = 5
Setting the functions of the keys Input in1 " Set parameter 240 = 7
Nr. 1112818
1 +24V 1
1
ST2 FA 2
2
4 0V 3
3
FW 4
4
7 in1
1 20 0V 1
1
16 +24V LSP 2
2
17 +24V 3
3
SUB-D-37
18 +24V
+24V 1
1
27 M3 FL 2
2
19 37
34 VR STV 1
1
35 FL +24V 2
2
37 M1
KL2237
Setting the functional sequence Thread trimming mode " Set parameter 290 = 5/21
Setting the functions of the keys Input in1 " Set parameter 240 =7
1
Nr. 1113178 +24V 1
ST2 +24V 2
4 0V +24V 3
+24V 4 10
7 in1 +24V 5 5 15
FL 6 4 14
1 20 9
FA 7 3 13
8
16 +24V FW 8 2 12
7
17 +24V STV 9 1 11
SUB-D-37
18 +24V ML 10 6
0V 11
LSP 12
26 +24V 13
27 M3 14
15
19 37
32 M5
33 +24V
34 VR
35 FL
37 M1
KL2405
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
EFKA FP220A5900 30
Setting the functional sequence Thread trimming mode " Set parameter 290 = 9
Setting the functions of the keys Input in1 " Set parameter 240 = 6
(Automatic setting) Input in3 " Set parameter 242 = 10
Nr. 1112826
1 0V 1
1
SUB-D-37
21 POS2Q LSP 2
6 3
3
5 2
4
4 1
28 M2 5
+5V 6
19 37
33 +24V
R
POS2Q 1
1
2
2
37 M1
KL2244
Adapter cord for YAMATO backlatch machine models ABT13 and ABT17
Setting the functional sequence Thread trimming mode " Set parameter 290 = 9
Setting the functions of the keys Input in1 " Set parameter 240 = 6
(Automatic setting) Input in3 " Set parameter 242 = 10
Input in4 " Set parameter 243 = 34
Nr. 1113205
1 0V 1
21 POS2Q LSP 2
6 3
3
5 2
4
4 1
28 M2 5
+5V 6
19 37
37 M1
1
2
6 3
3
5 2
N9-AUTO 4
4 1
POS2Q 5
6
KL2439
*) Rear view (soldering side) of 37-pin plug (ST2). Front view (component side) of the remaining plugs/sockets.
31 EFKA FP220A5900
6 Timing Diagrams
Mode 0 (lockstitch)
1
- 1/2
0
-1
+
-2
n n3 n2 n1 n2 n4 n7
POS.1 0 1 2 3 1 2 3 0 1 2 1 2 3
ST2/20
POS.2
ST2/21
FL t3 t8 t1 t9 t6 t7 t4 t5
ST2/35
VR c2 c1 c3 c4
ST2/34
M1 (FA1)
ST2/37
M2 (FA2)
ST2/28
M3 (FW)
ST2/27
M4 (FA1+2)
ST2/36
M5 (ML)
ST2/32
M6 (MST)
ST2/30
0256/MODE-0
Mode 2 (lockstitch)
1
- 1/2
0
-1
+
-2
n n6 n3 n2 n1 n4 n7 n7 n1 n1
POS.1 0 1 2 3 0 1 2 3
ST2/20
POS.2 SSc
ST2/21
FL t3 c1 t1 t3 c3 tFA tFL
ST2/35
VR
ST2/34
M4 (FL1)
ST2/36
kt2
M2 (FA)
ST2/28
M3 (FSPL)
ST2/27
M5 (ML)
ST2/32
M6 (MST)
ST2/30
NHT
0256/MODE-2
Mode 3 (lockstitch)
1
- 1/2
0
-1
+
-2
n n3 n2 n10 n2 n4 n7 n7
POS.1 0 1 2 3 1 2 3 1 2 3 4 5 6 7 0 1 2 1 2 3
ST2/20
POS.2 tFA
ST2/21
FL t3 t1 cHP tHP t7
ST2/35
VR c2 c1 c3 c4
ST2/34
M1 (FA) iFA
ST2/37
M2 (FSPL) FSE FSA
ST2/28
M3 (FW) t6
ST2/27
M5 (ML)
ST2/32
M6 (HP)
ST2/30
(LHP)
ST2/31
HP
0256/MODE-3
Mode 4 (chainstitch)
1
-
1/2
0
+ -1
-2
n n3 n2 n1 n4 n7
POS.1 0 1 2 3 4 5 6 7 012 3 4 5
ST2/20
POS.2
ST2/21
t3 t1 kdF t4 t5
FL
ST2/35
c1 c3
M4
ST2/36
M1
ST2/37
kd2 kt2
M2 (FA-V)
ST2/28
kd3 kt3
M3 (FW)
ST2/27
M5 (ML)
ST2/32
M6 (MST)
ST2/30
0256/MODE-4
Mode 5 (chainstitch)
1
- 1/2
0
-1
+
-2
n n6 n3 n2 n1 n4 n7
POS.1 0 1 23 0 1 2 3 1 2
ST2/20
POS.2 SSc
ST2/21
FL t3 c1 t1 t4 t5 t3 c3 c4 kdF
ST2/35
STV
ST2/34
M1 kd1 kt1
ST2/37
kd2 kt2
M2
ST2/28
kd3 kt3
M3
ST2/27
M4 kd4 kt4
ST2/36
M5 (ML)
ST2/32
M6 (MST)
ST2/30
0256/MODE-5
1
- 1/2
0
-1
+
-2
n n6 n2 n1
POS.1 0 1 2
ST2/20
POS.2 SSc
ST2/21
FL t3 t4 t5 kdF
ST2/35
STV
ST2/34
M2 (IMP) kt2
ST2/28
M5 (ML)
ST2/32
M6 (MST)
ST2/30
in1...i10
ST2/..
0256/MODE-5a
1
- 1/2
0
+ -1
-2
n n2 n5 n1 n1
POS.1 0 3 4 5 6 7
ST2/20
FL t3 LS t4 t5
ST2/35
STV
ST2/34
M5 (ML)
ST2/32
M6 (MST)
ST2/30
LS
ENTK
0256/ENTK-1
*) When unlocking the chain, the functions “stitch condensing” and “thread trimmer” are suppressed!
EFKA FP220A5900 38
1
- 1/2
0
+ -1
-2
n n2 n1 n2 n1 n1 n1
POS.1
ST2/20
FL t3
ST2/35
STV
ST2/34
M5 (ML)
ST2/32
M6 (MST)
ST2/30
ENTK
0256/ENTK-2
*) When unlocking the chain, the functions “stitch condensing” and “thread trimmer” are suppressed!
39 EFKA FP220A5900
1
- 1/2
0
-1
+
-2
n n6 n3 n2 n7 n6 n3 n2 n7
POS.1 0 1 23 0 1 23
ST2/20
FL t3 c1 t1 kdF t3 c1 t1 kdF
ST2/35
STV
ST2/34
M5 (ML)
ST2/32
M6 (MST)
ST2/30
AH
0256/MODE-6
Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 0 (seam end with stop)
1
- 1/2
0
+ -1
-2
n n3 n2 n1 n2 n5 n4 n7
POS.1 012345678 1 3 4 5 1 2 3 4 5 6 7
ST2/20
POS.2
ST2/21
FL t3 t3 LS kdF t4 t5
ST2/35
KS c1 c2
ST2/34
SFS
M4 (FSPL) SFS < c1
ST2/36
KLM ckL kt3 c4 kt3 KLM
M3 (AH)
ST2/27
M1 c3 kd1 kt1
ckL < c3 c4 < c2
ST2/37
kd2 kt2
M2
ST2/28
LS
M5 (ML)
ST2/32
M6 (MST)
ST2/30
0256/MODE-7a
Mode 7 (overlock) parameter 232 = 1 (fast scissors) / parameter 018 = 0 (seam end with stop)
1
- 1/2
0
+ -1
-2
n n3 n2 n1 n2 n5 n4 n7
POS.1 012345678 1 3 4 5 1 2 3 4 5 6 7
ST2/20
POS.2
ST2/21
FL t3 t3 LS kdF t4 t5
ST2/35
KS c1 c2
ST2/34
M4 (FSPL)
ST2/36
c3 kt3
M3 (AH1)
ST2/27
M1 kd1 kt1
c4 < c2
ST2/37
c4 kt2
M2 (AH2)
ST2/28
LS
M5 (ML)
ST2/32
M6 (MST)
ST2/30
0256/MODE-7c
Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 1 (seam end without stop)
1
- 1/2
0
+ -1
-2
n n3 n2 n4 n3 n2 n1 n7
POS.2
ST2/21
FL t3 kdF t4 t5
ST2/35
KS c1 c1
ST2/34
M4 (FSPL)
ST2/36
M1 kd1 kt1
ST2/37
M2 kd2 kt2
ST2/28
LS
M5 (ML)
ST2/32
M6 (MST)
ST2/30
0256/MODE-7b
1
- 1/2
0
-1
+
-2
n n6 n2 n12 n1 n6 n2 n1
0 1 2 0 1 2
POS.1
ST2/20
M1/PED -1
ST2/37
M2/PED +1
ST2/28
M3/PED +1
ST2/27
M5 (ML)
ST2/32
M6 (MST)
ST2/30
in3 (n12)
ST2/6
in1 (LSP)
ST2/7
0256/MODE-8 NA NE NA NE
*) When automatic speed is On, machine run blockage (safety switch) does not work!
NA Start of seam
NE Seam end
EFKA FP220A5900 44
1
- 1/2
0
-1
+
-2
n n6 n2 n12 n1 n6 n2 n9 n1
0 1 2 0 1 2
POS.1
ST2/20
M1/PED -1
ST2/37
M2/PED +1
ST2/28
M3/PED +1
ST2/27
M5 (ML)
ST2/32
M6 (MST)
ST2/30
in1 (LSP)
ST2/7
in3 (n12)
ST2/6
in4 (n9)
ST2/8
0256/MODE-9 NE NA NE NA
*) With this setting, machine run blockage (safety switch) takes priority over automatic speed!
**) Automatic speed n9 takes priority over machine run blockage (safety switch)!
NA Start of seam
NE Seam end
45 EFKA FP220A5900
Mode 10 (lockstitch)
1
-
1/2
0
+ -1
-2
n n3 n2 n1 n4 n7
0 1 2 3 4 5 6 7 012 3 4 5
POS.1
ST2/20
POS.2
ST2/21
FL t3 t1 t7 t4 t5
ST2/35
M4 c1 c3
ST2/36
M1 (FSPL)
ST2/37
M2 (FA-V)
ST2/28
M3 (FW) dFw t6
ST2/27
M5 (ML)
ST2/32
M6 (MST)
ST2/30
0256/MODE-10
Mode 14 (lockstitch)
1
- 1/2
0
-1
+
-2
n n3 n2 n1 n2 n4 n7
POS.1 0 1 2 3 1 2 3 0 1 2 1 2 3
ST2/20
POS.2
ST2/21
FL t3 t8 t1 t9 t6 t7 t4 t5
ST2/35
VR c2 c1 c3 c4
ST2/34
M1 (FA1+2)
ST2/37
kd4 kt4
M2 (FZ)
ST2/28
M3 (FW)
ST2/27
M4 (FA2)
ST2/36
M5 (ML)
ST2/32
M6 (MST)
ST2/30
0256/MODE-14
Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is Off / start of seam with light barrier covered
1
- 1/2
0
+ -1
-2
n n2 n1
POS.1 1 3 4 5 6 7
ST2/20
POS.2
ST2/21
FL t3 LS kdF t4 t5
ST2/35
M1 (KB)
ST2/37
M2 (KS)
ST2/28
M3 (FSPL) c1 c2
ST2/27
M4 (AH) c7 kt4 c8 kt4 kt4
ST2/36
VR (KS) kt6
ST2/34
LS
M5 (ML)
ST2/32
M6 (HP)
ST2/30
in4 (HP)
ST2/8
in5 (AH)
ST2/5
0256/MODE-15a
*) The value displayed on the control unit must be multiplied by 10. Example: The displayed value 10
corresponds to 100ms.
EFKA FP220A5900 48
Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is Off / start of seam with light barrier
uncovered
1
- 1/2
0
+ -1
-2
n n2 n1 n2 n1
POS.1 1 3 4 5 6 7
ST2/20
POS.2
ST2/21
FL t3 LS kdF t4 t5
ST2/35
M1 (KB)
ST2/37
M2 (KS)
ST2/28
M3 (FSPL) c1 c2
ST2/27
M4 (AH) c7 kt4 c8 kt4 kt4
ST2/36
VR (KS) kt6
ST2/34
LS
M5 (ML)
ST2/32
M6 (HP)
**)
ST2/30
in4 (HP)
ST2/8
in5 (AH)
ST2/5
0256/MODE-15c
*) The value displayed on the control unit must be multiplied by 10. Example: The displayed value 10
corresponds to 100ms.
**) Programming is possible at intermediate stop before tape cutting at the start of the seam!
49 EFKA FP220A5900
Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is On
1
- 1/2
0
+ -1
-2
n n2 n1
POS.1 1 3 4 5 6 7
ST2/20
POS.2
ST2/21
FL t3 LS kdF t4 t5
ST2/35
M2 (KS) c3
ST2/28
M3 (FSPL) c1 c2
ST2/27
LS
M5 (ML)
ST2/32
M6 (HP)
ST2/30
in4 (HP)
ST2/8
in5 (AH)
ST2/5
0256/MODE-15b
*) The value displayed on the control unit must be multiplied by 10. Example: The displayed value 10
corresponds to 100ms.
EFKA FP220A5900 50
Mode 16 (feed-off-the-arm machine) without automatically unlocking the chain with tape cutter (232 = 0)
1
- 1/2
0
+ -1
-2
n n3 n2 n1 n2 n5 n4 n7
POS.1 012345678 1 3 4 5 1 2 3 4 5 6 7
ST2/20
POS.2
ST2/21
FL t3 t3 LS kdF t4 t5
ST2/35
KS c1
ST2/34
M4 (FSPL)
ST2/36
M2 kd2 kt2
ST2/28
LS
M5 (ML)
ST2/32
M7 (STB) kt5
ST2/23
0256/MODE-16
*) The V810 control panel cannot be used for the functions in mode 16!
51 EFKA FP220A5900
Mode 16 (feed-off-the-arm machine) automatically unlocking the chain with tape cutting / 8 key on V820
On
1
- 1/2
0
+ -1
-2
n n2 n1 n2 n5 n4 n7
POS.1 1 3 4 5 1 2 3 4 5 1 2 3
ST2/20
POS.2 drd ird
ST2/21
FL t3 t3 LS t4 t5
ST2/35
KS c6
ST2/34
M4 (FSPL)
ST2/36
c4 kt3
M3 (AH)
ST2/27
ST2/37
M2
ST2/28
LS
M5 (ML)
ST2/32
M7 (STB)
ST2/23
0256/MODE-16a
*) The V810 control panel cannot be used for the functions in mode 16!
EFKA FP220A5900 52
1
- 1/2
0
-1
+
-2
n
n2 n7 n7 n2 n1 n7
POS.1
ST2/20
POS.2 dr dr
ST2/21
FL t3 kdF t3
ST2/35
VR (LFA) kd1 kt1 kd1 kt1
ST2/34
kd2 kt2 kd2 kt2
M2 (FA)
ST2/28
ST2/27
ML
ST2/32
0256/MODE-17
1
- 1/2
0
-1
+
-2
n n3 n2 n11 n9 n10 n2 n4 n7
POS.1 0 1 2 3 1 2 3 0 1 2 1 2 3
ST2/20
FL t3 c2 c1 t1 c3 c4 t7
ST2/35
VR
ST2/34
M1 (FA) iFA
ST2/37
M2 (FSPL) FSE FSA
ST2/28
in3 (BIT0)
ST2/6
in4 (BIT1)
ST2/8
0256/MODE-20
1
- 1/2
0
-1
+
-2
n n3 n2 n1 n4 n7 n7
POS.1 0 1 2 3 0 1 2 3
ST2/20
POS.2 tFA
ST2/21
FL t3 c1 t1 t4 t5 t3 c3 kdF
ST2/35
M2 (STV)
ST2/28
ST2/37
M5 (ML)
ST2/32
0256/MODE-21
Mode 23 (lockstitch)
1
- 1/2
0
-1
+
-2
n n3 n2 n10 n2 n4 n7 n7
POS.1 0 1 2 3 1 2 3 1 2 3 4 5 6 7 0 1 2 1 2 3
ST2/20
POS.2 tFA
ST2/21
FL t3 t1 cHP tHP t7
ST2/35
VR c2 c1 c3 c4
ST2/34
M1 (FA) iFA
ST2/37
ST2/36
t6
M3 (FW)
ST2/27
M2 (ML)
ST2/28
M5 (HP)
ST2/32
M11(LHP)
ST2/31
in1 (HP)
ST2/7
0256/MODE-23
*) If the key is pressed down longer than the cHP count, high lift for walking foot remains On as well. If the key
is pressed briefly, high lift for walking foot is On during counting, as shown in the timing diagram.
EFKA FP220A5900 56
Power on
1
-
1/2
0
+ -1
-2
n n2 n1 n2 n1 n2 n5 n7
POS.1 0 3 4 5 6
ST2/20
POS.2
ST2/21
FL dnL kdF
ST2/35 LS
M2 (FA)
ST2/28
M9
ST2/25
in3 (SEN)
ST2/6
in4
ST2/8
in2
ST2/11
0256/MODE-24
Outputs: Inputs:
FL = Sewing foot lifting in1 = Machine run blockage Pa. 240= 6
M1/M2 = Thread trimmer in2 = Switch bottom/sleeve hemming Pa. 241=13
M3 = Thread wiper in3 = Sensor input Pa. 242=28
M7 = Hemming guide in4 = Knee switch “hemming guide” Pa. 243=22
M8 = Hemming blow 1
M9 = Hemming blow 2
M6 = Display “bottom/sleeve hemming”
57 EFKA FP220A5900
Power on
1
-
1/2
0
+ -1
-2
n n2 n1 n2 n1 n2 n5 n7
POS.1 0 3 4 5 6
ST2/20
POS.2
ST2/21
FL dnL kdF
ST2/35 LS
kd2kt2
M1 (FA)
ST2/37
M2 (FA)
ST2/28
kd3 kt3
M3 (FW)
ST2/27
M7
ST2/23
M8
ST2/24
cb2
M9
ST2/25
in3 (SEN)
ST2/6
in4
ST2/8
in2
ST2/11
0256/MODE-24a
Outputs: Inputs:
FL = Sewing foot lifting in1 = Machine run blockage Pa. 240= 6
M1/M2 = Thread trimmer in2 = Switch bottom/sleeve hemming Pa. 241=13
M3 = Thread wiper in3 = Sensor input Pa. 242=28
M7 = Hemming guide in4 = Knee switch “hemming guide” Pa. 243=22
M8 = Hemming blow 1
M9 = Hemming blow 2
M6 = Display “bottom/sleeve hemming”
EFKA FP220A5900 58
7 List of Parameters
7.1 Preset Values Depending on Mode
The preset values which are different in the various modes are listed in the table below. When switching the mode by
means of parameter 290, these values change automatically.
Operator Level
Mode "0 2 3 4 5 6 7 8 9 10 14 15 16 17 20 21 23 24
Parameter
000 - - - - - - - - - - - 6 30 - - - - -
001 - - - 2 - - - - - 2 - 2 17 - - - - -
002 - - - - - - - - - - - 10 2 - - - 3 -
003 - - - - - - - - - - - 10 18 - - - 3 -
004 - - - - - - 0 - - - - 25 0 - - - - 35
005 - - - 0 - - - - - - - - - - - - 0 -
007 - - - - - - - - - - - - - - - - 10 -
008 - - - - - - 4 - - - - - - - - - 2 -
009 - - - - - - 1 - - - - 1 1 - - - - 1
013 - - - - - - - 0 0 - - 0 - - - - - -
014 - 0 - - - - 0 0 0 - - 0 0 - 0 - 0 -
019 - - - - - - 2 - - - - 2 2 1 - - - 3
021 - - - - - - - - - - - 23 - - - - - -
Technician Level
Mode " 0 2 3 4 5 6 7 8 9 10 14 15 16 17 20 21 23 24
Parameter
100 - - - - - - - - - 1 - - - - - - - -
** 110 - - - 180 - - - 250 250 180 - - - - - - 180 -
** 111 - - - 5000 - - - - - 4500 - 7500 3800 - 2500 5500 4800 5000
** 112 - - - - - - - - - - - - 3800 - 600 - 1700 -
** 113 - - - - - - - - - - - - 3800 - 600 - 1700 -
** 114 - - - - - - - - - - - - - - - - 1700 2000
** 115 - - - - - - - - - 700 - - - - - - 800 -
** 116 - - - - - - - - - - - - - - - - 180 -
** 117 - - - - - - - - - - - 9900 - - 1800 - 2000 9900
** 118 - - - - - - - - - - - - - - 2500 - 3000 -
119 - - - - - - - - - - - - 1 - - - -
** 122 - - - - - - - - 6000 - - - - - - - - -
** 123 - - - - - - - - - - - - - - 2400 - - 9900
130 - - - - - - 1 - - - - - 1 - - - - -
131 - - - - - - - - - - - 1 - - - - - -
132 - - - - - - 0 - - - - 0 0 - - - - 0
134 - - - - - - - - - 1 - - - - 1 - 1 -
135 - - - - - - - - - - - - - - 1 - - -
137 - - - - - - - - - - - - - - - 1 1 1
152 - - - - - - - - - - - - - - - - 100 -
153 - - - - - - - - - - 0 - - - - - 06 -
158 - - - - - - - - - - - - - - - - - 100
161 - - - 0 0 0 0 0 0 0 - 0 0 0 - 0 - 0
180 - - - - - - - - - 14 - - - - 45 - 14 -
181 - - - - - - - - - 230 - - - - - - 0 -
182 - - - - - - 1 - - 1 - - 1 - 1 - - -
184 - - - - - - - - - - - - - - - - - -
190 - - - 0 - - 2 - - - - - 1 - - - - -
192 - - - - - - 1 - - - - 1 1 - - - - -
194 - - - - - - - - - - - - 1 - - - - -
196 - - - - - - - - - - - - - - - 1 0 -
197 - - - - - - - - - - - - - 360 - - - -
x = The positions marked with ”x“ are not used in the functional sequence!
- = For the positions marked with “-“ the preset values listed in the List of Parameters are used !
** = When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
59 EFKA FP220A5900
Supplier Level
Mode " 0 2 3 4 5 6 7 8 9 10 14 15 16 17 20 21 23 24
Parameter
200 - - - - - - - - - - - - - - - - 50 -
201 - - - 160 - - - - - - - - - - - 200 - -
202 - - - - - - - 0 0 - - - - - - - 80 -
203 - - - 350 - - - - - - - - - - - - 200 -
204 - - - - - - - - - 12 - - - - - - - -
** 205 - - - - - - - - - 240 - - - - - - 100 -
206 - - - - - - - - - 150 - - - - - - 50 -
207 - - - - - - - - - - - - - - - - 10 -
209 - - - - - - - - - 100 - - - - - - - -
210 - - - - - - - - - - - - - - - - 100 -
211 - - - - - - - - - - - - - - - - 0 -
212 - - - 100 - - - - - 100 - - - - - - 200 -
213 - - - 12 - - - - - 12 - 100 - - - - 50 -
234 - - - - - - - 0 0 - - - - - - - - -
240 - - - 6 - - - 6 6 - - - 15 - 13 - 13 6
241 - - - - - - - - - - 16 - - - - - 07 14
242 - - - 3 - - - 10 38 - - - - - 31 - 01 28
243 - - - - - - - 1 34 - - 14 15 - 32 - 0 22
244 - - - - - - - - - - - 15 - - - - 16 -
245 - - - - - - - 12 12 - - - - - 16 - 0 -
246 - - - - - - - - - - - - - - 13 - 33 -
247 - - - - - - - - - - - - - - - - 11 -
248 - - - - - - - - - - - - - - - 14 28 -
249 - - - - - - - - - - - - - - - - 17 -
250 - - - - - - - - - - - - - - - - 280 -
** 253 - - - - - - - - - - - - - - 0 - 0 -
255 - - - 25 - - - - - 25 - - - - - - - -
260 - - - - - - - - - - - - - - - 100 - -
262 - - - - - - - - - - - - - - - 20 - -
269 - - - - - - - - 25 - - - - - - - - -
270 - - - - - - - - 1 - 3 - - - - 1 - -
271 - - - - - - - - - - 200 - - - - 4 - -
272 - - - - - - - - - - - - - - - - - -
** 274 - - - - - - - - - - - - 0 - - - - -
** 275 - - - - - - - - - - - - 100 - - - - -
** 280 x x x 100 - - 100 x x x - 10 - 100 - x - 100
** 281 - - - - - - - - - 280 - 50 1000 - - 250 - -
** 282 x 0 x 0 - - 200 x x x x 30 200 - - 40 - -
** 283 - - - 200 - - - - - - - 100 - - - 80 - -
** 284 x x x - - 0 0 x x 150 x - 0 - - 300 - 230
** 285 x x x - - - - x x 70 x - - 70 - 680 - -
** 286 x x x x - 0 0 x x x x 100 0 - - - - -
** 287 x x x x - - 0 x x x x 50 0 - - - 0 -
** 288 x x x - - - - x x x x - - 200 - - - -
291 - - - - 5 5 8 7 7 - - 7 7 5 - 5 - 5
292 - - - - 3 3 5 5 5 - - 5 7 3 - 3 - 3
293 - - - - - - - - - - - - - - - - - -
294 - - - - - - - - - - - 14 - - - - - -
Basic pos. 1 1 1 1 2 2 2 2 2 1 1 2 2 2 1 1 1 2
Single OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF
start
backtack
Double ON ON ON OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON ON ON OFF
start
backtack
Single OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF
end
backtack
Double ON ON ON OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON ON ON OFF
end
backtack
Note
The preset values of the following list of parameters refer to the setting of parameter 290 = 0.
x = The positions marked with ”x“ are not used in the functional sequence!
- = For the positions marked with “-“ the preset values listed in the List of Parameters are used !
** = When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA FP220A5900 60
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
61 EFKA FP220A5900
Operator Level
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
***) When programming the 5-digit (max) parameter values on the control or control panel, the 3-digit value displayed
must be multiplied by 100.
EFKA FP220A5900 62
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
63 EFKA FP220A5900
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA FP220A5900 64
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
65 EFKA FP220A5900
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
EFKA FP220A5900 66
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
67 EFKA FP220A5900
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA FP220A5900 68
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
69 EFKA FP220A5900
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA FP220A5900 70
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
71 EFKA FP220A5900
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA FP220A5900 72
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
360°
SEN
+5V
POS
IN 0V
B18/7
ST2/20
POS1
ST2/20
OUT
POS2 Pa 271
ST2/21
POS1
ST2/20
OUT
POS2 Pa 271
ST2/21
= 0V = high 0256/SEN-1
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
73 EFKA FP220A5900
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
360°
SEN
+5V
POS
IN 0V
B18/7
ST2/20
POS1
ST2/20
OUT
POS2 Pa 271
ST2/21
POS1
ST2/20
OUT
POS2 Pa 271
ST2/21
= 0V = high 0256/SEN-2
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
EFKA FP220A5900 74
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
75 EFKA FP220A5900
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Note
When selecting the trimming mode by means of parameter 290, the connected V810 or V820 control panel is
automatically sensed and the corresponding slide-in strip number is selected by means of parameter 291 and 292,
respectively. Should a different strip be inserted, its number can be set by means of parameter 291 and 292, respectively,
after having selected the trimming mode.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
77 EFKA FP220A5900
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
EFKA FP220A5900 78
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
79 EFKA FP220A5900
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter
0 1 0 0 0 0 0
100
0 1 1 100 0 0 0
10
0 1 2 0 0 10 0
100
1 1 0 0 100 0 0
100 100
1 1 1 100 100 0 0
10
3 1 0 0 0 0 10
10 10
3 1 2 0 0 10 10
100 10
3 1 1 100 0 0 10
10 100
1 1 2 0 100 10 0
100
1 2 0 0 100 0 0
100 100
1 2 1 100 100 0 0
0256/BILD4
NA = Start of seam
LS = Light barrier uncovered or covered at the seam end
NE = Seam end
FA-E = End thread trimming operation
P=0 = Pedal in pos. 0 (neutral)
St = Stitches
Parameter
0 0 0 0 0 0 0 1)
0 0 0 0 0 0 0 2)
100
1 0 0 0 100 0 0
100 100
1 0 1 100 100 0 0
10
3 0 0 0 0 0 10
10 10
3 0 2 0 0 10 10
100 10
3 0 1 100 0 0 10
10 100
1 0 2 0 100 10 0
2 0 0 0 0 0 0 1)
2 0 0 0 0 0 0 2)
100
0 0 1 100 0 0 0
10
0 0 2 0 0 10 0
100
1 3 0 0 100 0 0
100 100
1 3 1 100 100 0 0
10
3 3 0 0 0 0 10
10 10
3 3 2 0 0 10 10
100 10
3 3 1 100 0 0 10
10 100
1 3 2 0 100 10 0
2 3 0 0 0 0 0
0 3 0 0 0 0 0
100
0 3 1 100 0 0 0
10
0 3 2 0 0 10 0
100
2 3 1 100 0 0 0
10
2 3 2 0 0 10 0
0256/BILD3
NA = Start of seam
LS-D = Light barrier uncovered " covered (parameter 131 = 1 and parameter 132 = 0)
NE = Seam end
FA-E = End thread trimming operation
P=0 = Pedal in pos. 0 (neutral)
St = Stitches
8 Error Displays
General Information
On the control On the V810 On the V820 Signification
Returns to 000 Returns to 0000 Like V810 + Wrong code number or parameter number
or to last or to last display InFo F1 input
parameter number parameter
number
Serious Condition
On the control On the V810 On the V820 Signification
E2 InF E2 InFo E2 Line voltage too low, or time between power off
and power on too short.
Hardware Disturbance
On the control On the V810 On the V820 Signification
1
R F
2
R F F1 F2
3
R F
4
R F F1 F2
R 5
F1 F2
6
1 2
F INSERT F1 DELETE F2
7
F1 F2
8
1 2
F INSERT F1 DELETE F2
9
1 2
F
INSERT F1 DELETE F2
10
1 2
F INSERT F1 DELETE F2 KL2256e
Note
When changing the setting of parameters 291 / 292, the V810 / V820 functions change as well, save function keys
F1 / F2 which are influenced by parameters 293 /294.
83 EFKA FP220A5900
OF AMERICA INC.
3715 NORTHCREST ROAD – SUITE 10 – ATLANTA – GEORGIA 30340
PHONE: (770)457-7006 – TELEFAX: (770)458-3899 – email: efkaus@efka.net